  • www.cmsglobal.com EXCELAIR LIVE | Technical Catalogue | Filter Housings 4

    EXCELAIR TERMI RSRLDucted Laminar flow Terminal Housing Box TERMI RSRL

    EXCELAIR RSRL Terminal Housing Boxes are ideal for clean room applications for supplying Laminar flow air to provide clean air. EXCELAIR Terminal Housing boxes are compact in design and easy to install. It has Provision for easy connection to the duct. Installation of box is so easy by using the fasteners and duct connection is through the flexible ducts or some other duct connectors. Terminal Housing Box with Top opening with Damper control is also available.

    The Housing Box shall be designed according to the Airflow & Velocity requirements.

    Construction Details & Features of Housing Box Construction: EXCELAIR Terminal Housing Box is made up of MS / GI Sheets with powder coated finish. The hood shall be made up of Stainless steel upon request.

    Duct Connection The hood shall have an integral duct connected spigot in the side to connect to the flexible duct easily. The spigot diameter shall be 200 mm, 250mm or305mm. The hood shall have an opening option at the top. It may be round or rectangular spigot provision with flanges to connect to the duct easily.

    Installation The Terminal hood shall have the side Hanging Tabs, permanently welded with the hood, having 10 mm Dia hole to fasten it. The hanging tabs are to hang with threaded rods or to fix with some HVAC work place in operation theatre.

    Filter Installation The hood shall have a channel to fix the Hepa filters and the filters clamped with help of SS fasteners with the box. Filter Replacement is from the front side of the housing box by removing the socket and the fasteners.

    s "ESTFOR,AMINARmOWs ,IGHTINWEIGHTs %ASY)NSTALLATIONs 7IDERANGEOF(EPA&ILTER#HOICESs $IFFERENT$IFFUSION'RILLESs !VAILABLEIN0OWDERCOATED3TAINLESS3TEELs Suitable for Cleanrooms,Hospitals, Pharmaceutical firms, Bio Technology Lab

    sssssss

  • Excelair Live | Technical Catalogue | Filter Housings www.cmsglobal.com

    Filter selection The Hepa filter shall be selected as per the Clean room standard ISO 14644 to ensure the quality of High efficiency filter.

    The operating maximum velocity of the filter is 100 fpm. The Filter dimension is based on the Airflow. For selection of filters, contact the factory.

    Air Distribution PlateThe Terminal hood shall have distribution plate made up of SS / MS, located in the Plenum inlet collar, to diffuse the air as it enters the plenum ensuring uniform airflow through the filter.

    Diffuser / Diffusion Plate / GrilleThe Diffusion plate shall be perforated Mirror finish Stainless steel sheet having 40% open area. The corners of the plate is hemmed. The diffuser is easily mountable for the replacement of the filters directly from the room side. The Diffuser shall clamp with the Hood by Stainless steel screws. 4-way Extruded Aluminum Powder coated diffuser and swirl diffuser shall be fixed as an option.

    Pressure Measurement Test Port A Test port shall be provided adjacent to the knife edge and shall be accessible from the room side of the hood while the filter is installed and the grille is removed. The test port shall be designed to measure final pressure drop for the replacement of the filters. The Housing box shall be supplied with Differential Pressure Switch too.

    Testing & Quality Check All the hoods shall be visually inspected and tested as per the standards for leak proof.

    Note: For the size, drawing and selection, contact factory.

    RSRL FILTER - 4 WAY DIFFUSER RSRL FILTER - LAMINAR DIFFUSER

  • www.cmsglobal.com EXCELAIR LIVE | Technical Catalogue | Filter Housings 6

    RSRL TWO STAGES (WITH PRE FILTER) RSRL FILTER ARRANGE-MENT

    RSRL ISOMETRIC VIEW RSRL FILTER FIXING

    ADDITIONAL OPTIONSs Removable Stainless Steel Diffuser s Insulation Materialss Aerosol Injected Nozzles Seismic Tabss Heavy Duty Dampers %XTENDED3TAINLESS3TEEL'RILL7ITH$03WITCHES

  • 7Excelair Live | Technical Catalogue | Filter Housings www.cmsglobal.com

    Housing Details &ILTER)NITIAL2ESISTANCE)N7' FPMTermi RSRL Standard Air Flow

    (CFM)LFA-H14 LFB-H14 LFC-H14 MP GEL-H14

    RSRL 1 100 0.49 0.38 0.33 0.49

    RSRL 2 200 0.49 0.38 0.33 0.49

    RSRL 3 300 0.49 0.38 0.33 0.49

    RSRL 4 400 0.49 0.38 0.33 0.49

    RSRL 5 600 0.49 0.38 0.33 0.49

    RSRL 6 800 0.49 0.38 0.33 0.49

    The Filter Replaceable Terminal Module RSRL is designed for applications that require frequent filter testing and routine cleaning procedures as in hospitals, surgical rooms, pharmaceutical firms and biotechnology Cleanrooms.

    The Filter is easy to install, change and provides an optimum service life. A gel seal between the filter and hood eliminates any by-pass of air leakage.

    The RSRL module shall have the filter depth range from 66mm to 150mm profile depth.

    4HE(EPAlLTERSSHALLHAVETHEEFlCIENCYOF -ICRONSATMICRONparticle size.

    Housing Details &ILTER)NITIAL2ESISTANCE)N7' FPM

    Termi RSRLStandard Air Flow

    (CFM)LFA-H13 LFB-H13 LFC-H13 MP GEL-H13

    RSRL 7 100 0.44 0.33 0.29 0.44

    RSRL 8 200 0.44 0.33 0.29 0.44

    RSRL 9 300 0.44 0.33 0.29 0.44

    RSRL 10 400 0.44 0.33 0.29 0.44

    RSRL 11 600 0.44 0.33 0.29 0.44

    RSRL 12 800 0.44 0.33 0.29 0.44

    SELECTION CHART

    SELECTION CHART