TENS 7000...TENS 7000 UNIT For more information about your TENS 7000 unit, please visit us online at...

2
The purpose of this guide is to assist you in correctly operating your TENS 7000™ unit. Do not use this device for undiagnosed pain symptoms until consulting a physician. This guide is not intended to replace or substitute the TENS 7000™ Instruction Manual. PLEASE READ THE INSTRUCTION MANUAL COMPLETELY BEFORE USING THIS DEVICE. Read, understand and practice the contraindications, warnings, cautions and operating instructions found on pages 4 – 5 of your instruction manual. Always follow the operating instructions as listed in the manual. QUICK REFERENCE GUIDE PAGE 1 1 2 Top Side Front 3 4 5 6 7 8 9 10 Lead connector sockets - 2 channels On / / intensity dial - 2 channels Panel cover with reference guide Liquid crystal display (LCD) Mode selection button Set selection button Increment control / increase button Increment control / decrease button Protective cover Belt clip 1 2 3 4 5 6 7 8 9 10 TENS 7000 UNIT For more information about your TENS 7000™ unit, please visit us online at www.roscoemedical.com or call 1-800-376-7263. The placement of electrodes can be one of the most important parameters in achieving success with TENS therapy. If the initial results are not positive, speak to your physician about alternative stimulation settings and/or electrode placement. Once desired results are achieved, mark down the electrode sites and settings for future reference. The TENS 7000™ features two protective covers that prevent unintentional changes to settings. Turn on device by rotating the dial clockwise and select the desired intensity level. device by turning dial counterclockwise to O. Low battery indicator signals when battery is low. Replace battery when stimulation feels weaker. SPECIAL FEATURES INSERT BATTERY Press arrow and slide battery compartment cover open. Insert 9V battery, matching the + and – ends to those in unit. The battery should be placed on top of the compartment ribbon to allow easy battery removal. LEAD WIRES ELECTRODES TENS 7000

Transcript of TENS 7000...TENS 7000 UNIT For more information about your TENS 7000 unit, please visit us online at...

Page 1: TENS 7000...TENS 7000 UNIT For more information about your TENS 7000 unit, please visit us online at or call 1-800-376-7263. The placement of electrodes can be one of the most important

The purpose of this guide is to assist you in correctly operating your TENS 7000™ unit. Do not use this device for undiagnosed pain symptoms until consulting a physician. This guide is not intended to replace or substitute the TENS 7000™ Instruction Manual. PLEASE READ THE INSTRUCTION MANUAL COMPLETELY BEFORE USING THIS DEVICE. Read, understand and practice the contraindications, warnings, cautions and operating instructions found on pages 4 – 5 of your instruction manual. Always follow the operating instructions as listed in the manual.

QUICK REFERENCE GUIDE PAGE 1

1

2Top

Side

Front

3

4

56

7

8

9

10

Lead connector sockets - 2 channels

On / / intensity dial - 2 channels

Panel cover with reference guide

Liquid crystal display (LCD)

Mode selection button

Set selection button

Increment control / increase button

Increment control / decrease button

Protective cover

Belt clip

1

2

3

4

5

6

7

8

9

10

TENS 7000™ UNIT

For more information about your TENS 7000™ unit, please visit us online at www.roscoemedical.com or call 1-800-376-7263.

The placement of electrodes can be one of the most important parameters in achieving success with TENS therapy. If the initial results are not positive, speak to your physician about alternative stimulation settings and/or electrode placement. Once desired results are achieved, mark down the electrode sites and settings for future reference. The TENS 7000™ features two protective covers that prevent unintentional changes to settings.

Turn on device by rotating the dial clockwise and select the desired intensity level. device by turning dial counterclockwise to O.

Low battery indicator signals when battery is low. Replace battery when stimulation feels weaker.

SPECIAL FEATURES INSERT BATTERY

Press arrow and slide battery compartment cover open. Insert 9V battery, matching the + and – ends to those in unit.

The battery should be placed on top of the compartment ribbon to allow easy battery removal.

LEAD WIRES

ELECTRODES

TENS 7000™

Page 2: TENS 7000...TENS 7000 UNIT For more information about your TENS 7000 unit, please visit us online at or call 1-800-376-7263. The placement of electrodes can be one of the most important

2 CONNECT LEAD WIRES TO DEVICE 3 PLACE ELECTRODES

ON SKIN

4 TURN DEVICE ON ANDSELECT INTENSITY 6 SELECT PULSE WIDTH

The pulse width is adjusted from 50us to 300us. Press the SET button to enter this menu, then press the and buttons to adjust the setting. Unless otherwise instructed, a setting of 70-120us is suggested.

7 SELECT PULSE RATE 8 SET THE TIMER

The treatment time is adjustable from 1 to 60 minutes, or Continuous ( C ). Press the and buttons to adjust the setting. Your settings will be stored permanently unless they are adjusted again.

5 SELECT THERAPY MODE

This unit can store 60 sets of operation records. The total treatment time can store up to 999 hours.

To check and/or delete individual records, press the MODE button as you turn on the device. The LCD will show the number of records and operation time. Press the and buttons to check each record. To delete a record, press and hold the SET button for 3 seconds.

To check and/or delete the accumulative record, press the MODE button to switch to this setting. Press

seconds; all of the records will be deleted, followed by the sound of a beep.

COMPLIANCE METER

Please see page 26 of your TENS 7000™ Instruction Manual for troubleshooting tips.PROBLEMS WITH YOUR DEVICE?

Steps 1 – 3 should be performed with the device turned OFF.Once the unit has been turned ON, do not remove the belt IMPORTANT!

QUICK REFERENCE GUIDE PAGE 2

There are 5 modes available: Burst, Normal, Modulation, SD1 and SD2. Press the MODE button and continue to press until you have reached your desired setting.

1 CONNECT LEAD WIRES TO ELECTRODES

The stimulation output will increase as the dial is turned clockwise or to a higher number.1 = Weaker 8 = Stronger

By turning the controls clockwise, the appropriate channel is switched on and the indicator of power (CH1 and CH2) is revealed in the LCD.

The pulse rate is adjusted from 2Hz to 150Hz. Press the SET button to enter this menu, then press the and buttons to adjust the setting. Unless otherwise instructed, a setting of 70-120Hz is suggested.

ON/Increase

Select one of the two available channels and insert the lead

the socket.

Firmly insertthe end of the lead wire pin into the electrode connectors.

Make sure the connection is complete and no bare metal of the pins is exposed.

Remove electrodes from protective backing. Keep backing to properly store electrodes after use.

Before applying electrodes, make sure the skin at the application site is clean and dry.

See Electrode Placement Guide for more information.