TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760,...

37
PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: [email protected] PROJECT / CLIENT PROJECT No. SCALE DATE DRAWN CHECKED DRAWING TITLE DRAWING NUMBER REVISION REV DATE AMENDMENT 2 NAEIC Shire of Northam D367 CW CM 01/11/17 Cover Joinery 1 J 1.00 TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 DRAWING LIST All drawings in this list are to be read in combination with Specification (attached). Contractor to coordinate Engineering review and incorporate corrosponding costs within your quotation. Any and all changes to the design to be negotiated with Thylacine. Dimensions of all joinery housing hardware (including the graphic ribbon) may need modification once AV hardware supplier provide the exact dimenison fo the 55" monitors Contractors to work closely with all other contractors. If in doubt - ASK. DRAWING LIST JOINERY Drawing NO. Drawing Title J 1.00 Cover Joinery 1 J 1.01 Joinery Plan J 1.02 Dimensioned Furniture Plan J 1.02B Dimensioned Furniture Plan Grid J 1.03 Plan Graphic Ribbon J 6.01 Joinery 01 J 6.02 Joinery 02 J 6.03A Joinery 03 Maptable J 6.03B J_03 Section J 6.03C J_03 General Assembly J 6.03D J_03 Specification J 6.04 Joinery 04 J 6.05 Joinery 05 J 6.06A Joinery 06 J 6.06B J_06 Drawer J 6.07 Joinery 07 J 6.08 Joinery 08 J 6.09 Joinery 09 J 6.10 Joinery 10 J 6.11 Joinery 11 J 6.12 Graphic Ribbon Section 1&2 J 6.13 Graphic Ribbon Section 3, 4, 5 J 6.14 Graphic Ribbon 6, 7, 8 J 6.15 Graphic Ribbon 9 & 10 J 6.16 Conclusion J 6.17 Plan Media J 6.18 Audio Stations J 6.19 Entry Sign J 7.01 Detail Construction Joinery Units J 7.02 Detail Construction Graphic Ribbon J 7.03 Detail Construction Lightbox interactive J 7.04 Acrylic cases in Graphic Ribbon and Standoffs J 7.05 Freestanding Monitor Mount J 7.06 Graphic Ribbon Monitor Mount J 7.07 Batten Monitor Mount J 7.08 Joinery & Showcase lighting Plan J 7.09 Mirrored wall 1 29/09/17 For Tender Draft 2 01/11/17 For Tender

Transcript of TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760,...

Page 1: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT

2NAEIC

Shire of Northam

D367

CW CM 01/11/17

Cover Joinery 1 J 1.00

TENDER DOCUMENTATION - NOT FOR CONSTRUCTION

JOINERY PACKAGE 1

DRAWING LIST

All drawings in this list are to be read in combination with Specification (attached).

Contractor to coordinate Engineering review and incorporate corrosponding costs within

your quotation. Any and all changes to the design to be negotiated with Thylacine.

Dimensions of all joinery housing hardware (including the graphic ribbon) may need

modification once AV hardware supplier provide the exact dimenison fo the 55" monitors

Contractors to work closely with all other contractors.

If in doubt - ASK.

DRAWING LIST JOINERY

Drawing NO. Drawing Title

J 1.00 Cover Joinery 1

J 1.01 Joinery Plan

J 1.02 Dimensioned Furniture Plan

J 1.02B Dimensioned Furniture Plan Grid

J 1.03 Plan Graphic Ribbon

J 6.01 Joinery 01

J 6.02 Joinery 02

J 6.03A Joinery 03 Maptable

J 6.03B J_03 Section

J 6.03C J_03 General Assembly

J 6.03D J_03 Specification

J 6.04 Joinery 04

J 6.05 Joinery 05

J 6.06A Joinery 06

J 6.06B J_06 Drawer

J 6.07 Joinery 07

J 6.08 Joinery 08

J 6.09 Joinery 09

J 6.10 Joinery 10

J 6.11 Joinery 11

J 6.12 Graphic Ribbon Section 1&2

J 6.13 Graphic Ribbon Section 3, 4, 5

J 6.14 Graphic Ribbon 6, 7, 8

J 6.15 Graphic Ribbon 9 & 10

J 6.16 Conclusion

J 6.17 Plan Media

J 6.18 Audio Stations

J 6.19 Entry Sign

J 7.01 Detail Construction Joinery Units

J 7.02 Detail Construction Graphic Ribbon

J 7.03 Detail Construction Lightbox interactive

J 7.04 Acrylic cases in Graphic Ribbon and Standoffs

J 7.05 Freestanding Monitor Mount

J 7.06 Graphic Ribbon Monitor Mount

J 7.07 Batten Monitor Mount

J 7.08 Joinery & Showcase lighting Plan

J 7.09 Mirrored wall

1 29/09/17 For Tender Draft

2 01/11/17 For Tender

Page 2: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

J_11

Graphic Ribbon 02

Graphic R

ibbon 03

Graphic Ribbon 06

Graphic Ribbon 07

Gra phic Ribbon 01

SCG_01

Gra

phic

Ribb

on 0

4 G

raph

ic Ri

bbon

05

MM2.2

MM2.3

MM4.1

MM4.2

MM4.3

MM2.1

GR09

GR10

MM3.1

MM3.2

J_01

J_02

J_05

J_06

J_07J_08

J_10

J_09

GR01

GR02

GR03

GR04

GR05

GR06

GR08

GR07

Graphic Ribbon 06

Graphic Ribbon 09

Gra

phic

Rib

bon

10J_03

J_04

MM5

AC_01

AC_02

AC_03

AC_04

SC_01

SC_02

SC_03

SC_05

SCG_06

Conclusion Wall

Graphic Ribbon 08

SCG_03

SCG_04

SCG_05

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 100

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery Plan J 1.011 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 3: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

D

E

F

G

H

I

1 2 3

SCW_01

SCG_01MM2.1

SCG_03

SCG_04

SCG_06

MM2.3

MM2.2

SCG_05

3580

4040

2620

3130

3500

2740

19901240

13301101400

4630

4300

6080

1980140

2510

1980 100

540

180 940

4920

2050

110

970

1200

2026

0

1240

1407

70

2320

21502190

910

2820

130

2680

4410

960 90 1140

1480

1710

3250

620

1840

10001940

4080

4470

1130

1370

220

5670

2270

9350

7600

4680

6930

5780

2260

750

1610 71

0

2740

2860

2460

360

3220

2270

30038

70

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 100

2NAEICShire of Northam

D367

CW CM 01/11/17

Dimensioned FurniturePlan J 1.02

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 4: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

D

E

F

G

H

I

1 2 3

548

1402

284

522728

3429

1120

538

552

2858

2002

2333

8021334

5833

88

3293

2071110

1811

13441054

3049

1945144

1217168

3773

2134

238

624

2134

215

2215

542

2283

1430

12

3152

573

1533

1234

1341

1016

441

1412

284 1398

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 100

2NAEICShire of Northam

D367

CW CM 01/11/17

Dimensioned FurniturePlan Grid J 1.02B

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 5: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

MM2.1Graphic Ribbon 02

2304

2452

Graphic ribbon 033680

372

724

724

Graphic Ribbon 06

18

6165

308

1001

Graphic Ribbon 07

4055

777

1218

19293339

46471518

7143450

1876

2126

2253Graphic Ribbon 09

2400

Graphic Ribbon 102601

5523

Graphic Ribbon 01 NOM

Grap

hic R

ibbon

04Gr

aphic

Ribb

on 05

AC01

AC02

AC03

AC04

2357

2660

Conclusion wall Refer J6.16

7634

NOTES

Dimensions as noted are nominal and based on architectural construction documents. Full, as built, site measure prior to construciton required to ensure accurate length and radius dimensions for graphic ribbon joinery. Any discrepencies with nominal dimensions as drawn here to be discussed with Designer. Exact dimensions of graphic ribbon to be provided to designer for graphic art work to ensure fit.

Shadowlines at all intersections have been drawn at 9mm width to allow for a requried shadowline plus tolerances. A minimum of 6mm and a maximum of 12mm shadowline is required. Accurate site measure prior to fabrication should ensure this. Any discrepencies beyond these tolerances must be discussed with Designer.

Shadowline spacer height and location relative to graphic ribbon as drawn in elevation. Shadowline spacer depth 13mm from face of graphic ribbon. Spacer to be painted NT16

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

1NAEICShire of Northam

D367

CW CM 29/09/17

Plan Graphic Ribbon J1.03

1 : 100J1.03Graphic Ribbon Plan1

1 29/09/17 For Tender Draft

Page 6: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

J 6.012

1097938

797

737

910 1125

1534

2035

R 3750

1146

Grain Removable panel Keku fixed

783mm

FFL

850mm

50mm

Removable Panel

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 01 J 6.01

1 : 20J 6.01J_01 Plan1

J 6.01J_01 Perspective3

1 : 20J 6.01Elevation J_012

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 7: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

J 6.02 2

1497 1792 190

3479

798

447

1236

1549

R 3750

R 2394

3425

2102

1246

2785

Grain

Removable panel Keku fixed

783mm

FFL

850mm

50mm

Removable PanelNT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 02 J 6.02

1 : 20J 6.02J_02 Plan1

J 6.02J_02 Perspective3

1 : 20J 6.02Elevation J_022

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 8: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

1J 6.03B

2J 6.03A

1500

1680

NT09

2512

FFL0

RL850

4J 6.03A

5J 6.03A

FAN 75mm STEEL STUD FIXED TO TABLE TOP

150

67

506

163

FFL0

RL850

5017

633

150

200

5015

0

50 FFL0

50

STE

P

200

30 X 30 X 2MM SHS

16MM MDFREMOVEABLE

KEKU CLIP

ADJUSTABLE FOOT

STEP JOINERY

180

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CW 01/11/17

Joinery 03 Maptable J 6.03A

1 : 25J 6.03AFFL1

2 X MONITORS -TO MULTIMEDIACONSULTANT'SSPECIFICATIONS

1 : 25J 6.03ASECTION2

1 : 2J 6.03ADETAIL 14

PR1820E1

MULTI TOUCH MONITORFIXED TO ADJUSTABLE

3MM ALUMINIUM WRAPPED ON 16MM MDF TOP AND END

6MM TOUGHENED GLASS

1 : 25J 6.03AELEVATION3

16MM MDFREMOVEABL

E

16/6/16MM MDF GLASS

1 : 2J 6.03ADETAIL 25

1 29/09/17 For Tender Draft2 01/11/17 For Tender

NOTE: DESIGN TO BE REVIEWED AND APPROVED BY HARDWARE CONTRACTOR, DIMENSIONS OF MONITOR MAY CHANGE

Page 9: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

150

ADJUSTABLE BASE

30 X 30 X 3 SHS STEEL

16MM MDF REMOVEABLE PANELS

STANDING DESK - HEIGHT ADJUSTABLEJP OFFICE WORKSTATION 'ELIZABETH'

700

850

MULTI TOUCH MONITOR FIXED TO ADJUSTABLE

PERFORATED ALUMINIUM

STEP JOINERY UNITFIXED TO UNIT AFTER FEET

1500

174

156

150

1000

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 5

2NAEICShire of Northam

D367

CW CM 01/11/17

J_03 Section J 6.03B

1 : 5J 6.03BSECTION 11

1 29/09/17 For Tender Draft2 01/11/17 For Tender

NOTE: DESIGN TO BE REVIEWED AND APPROVED BY HARDWARE CONTRACTOR, DIMENSIONS OF MONITOR MAY CHANGE

Page 10: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

3MM ALUMINIUM

16/6/16MM MDF GLASS CLAMP

PR1820E1

6MM TOUGHENED GLASS

2 X MULTI TOUCH MONITORS

16MM MDF FRAME DRESSING

75mm STEEL STUD FIXED TO TABLE TOP

30 X 30 X 2MM SHS

STEP JOINERY

'NIMBLE' HEIGHT ADJUSTABLE TABLE FROM JP OFFICE WORKSTATIONS

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT

2NAEICShire of Northam

D367

CW CM 01/11/17

J_03 General Assembly J 6.03C

J 6.03CEXPLODED VIEW1

J 6.03CPERSPECTIVE FRONT2

REMOVEABLE BACK SECTION

J 6.03CPERSPECTIVE BACK3

1 29/09/17 For Tender Draft2 01/11/17 For Tender

NOTE: DESIGN TO BE REVIEWED AND APPROVED BY HARDWARE CONTRACTOR, DIMENSIONS OF MONITOR MAY CHANGE

Page 11: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 1

1NAEICShire of Northam

D367

CW CM 01/11/17

J_03 Specification J 6.03D1 01/11/17 For Tender

Page 12: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

J 6.04

2

1404

882 1576

2457

808

1312

9992

R 25

91

863

38.70°

Grain

200mm

FFL

50mm

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 04 J 6.04

1 : 20J 6.04J_04 Plan1

J 6.04J_04 Perspective4

1 : 20J 6.04Elevation J_042

Add appropriate bracing for structure strenght

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 13: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

1232 571

1803

1097 706

131

1218

650

593

1243 13

49

R 2942

R 5905

1246

719

J 6.05 2Grain

Removable panel Keku fixed

783mm

FFL

850mm

50mm

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 05 J 6.05

1 : 20J 6.05J_05 Plan1

J 6.05J_05 Perspective3

1 : 20J 6.05Elevation J_052

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Removable Panel

Page 14: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

1140

1140

CL

401 1653

2056

1460

1024

965

1520

2484

R 55

76

R 474

4

1954

2291J 6.06A2

GrainRemovable panel Keku fixed

783mm

FFL

850mm

50mm

783mm

FFL

850mm

50mm

Removable Panel

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 06 J 6.06A

1 : 20J 6.06AJ_06 Plan1

J 6.06AJ_06 Perspective4

1 : 20J 6.06AJ_06 Elevation3

1 : 20J 6.06AElevation J_062

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 15: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

2J 6.06 B 12

00

587

1639

3916

800

400

3J 6.06 B

236

274

555 16

200

2J 6.06 B 4

J 6.06 B

1690

120.00°

150

400 800

9253

92

1910

1620

010

19

20

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

J_06 Drawer J 6.06 B

1 : 10J 6.06 BTop View1

1 : 10J 6.06 BSection 22

1 : 10J 6.06 BSection 13

1 : 2J 6.06 BSection 1 - Callout 14

HAFELE DRAWER RUNNER422.22.551

MATERIAL FRAME: 19mm Maari veneered PLYMATERIAL DRAWER: 16mm Maari veneered PLYFINISH: Refer Joinery notes J1.01

J 6.06 BPerspective5

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 16: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

1102 258

623

1414

2037

1361

R 55

76

R 47

44

1210

1503

J 6.07 2

Grain

Removable panel Keku fixed

450mm

FFL50mm

Removable Panel

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 07 J 6.07

1 : 20J 6.07J_07 Plan1

J 6.07J_07 Perspective3

1 : 20J 6.07Elevation J_072

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 17: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

1897 1988

3885

3080 805

498

142

116

844

960

R 14658

R 40729

3103

1992

J 6.08

2

Grain

Removable panel Keku fixed

783mm

FFL

850mm

50mm

Removable Panel

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 08 J 6.08

1 : 20J 6.08J_08 Plan1

J 6.08J_08 Perspective3

1 : 20J 6.08Elevation J_082

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 18: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

716 1792

746

341

263

824

1087

2508

R 1

3903

R 1

8287

1825

2523

J 6.092Grain

Removable panel Keku fixed

783mm

FFL

850mm

50mm

Removable Panel

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 09 J 6.09

1 : 20J 6.09J_09 Plan1

J 6.09J_09 Perspective3

1 : 20J 6.09Elevation J_092

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 19: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

J 6.10 2

1661 354

1134

1060

809

1385

2193

R 9739

R 3254

2364

2167

Grain

Removable panel Keku fixed

450mm

FFL50mm

Removable Panel

NT10

NT15

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 10 J 6.10

1 : 20J 6.10J_10 Plan1

J 6.10J_10 Perspective3

1 : 20J 6.10Elevation J_102

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 20: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

133

2922

500

3555

2225 482

2707

R 2308R 2808

5167

4247

J 6.11 2

Grain

Grain

Grain

450mm

FFL50mm

NT10

NT15

Removable top

Refer J7.01: all corners/ edges less than 90 degrees to be champhered 3mm Refer 6.17 + 6.18: for audio station CNC routed rebates,

CNC file to be provided by designer

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 20

2NAEICShire of Northam

D367

CW CM 01/11/17

Joinery 11 J 6.11

1 : 20J 6.11J_11 Plan1

J 6.11J_11 Perspective3

1 : 20J 6.11Elevation J_112

BATTENED SCREEN BY OTHERS

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 21: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

2J6.12

2J6.12

1858 5532 NOM.

2J7.02

3J6.12

2306 NOM.

2354 NOM.

Graphic ribbon 2

2658 NOM.

2453

2769

1J7.03

7381 NOM.

9 1840 9 18 2689 1280 18 1500 18

butt join at top

Monitor Refer Construction Detail for mounting

Graphic Ribbon 01

1J7.02

5J7.01

NT16

2780189

9 mm NOM. shadow for adjustment

2726

649

Showcase

1200

start

of cu

rveShadowline between graphic ribbon end and wall

9mm Shadowline between graphic ribbon end showcase side

2090

Showcase by otherssh

adow

line

1230

14822816 butt join at intervals1858butt join at intervals

Window with steel plate surround by builder

9 shadowline4506

161502

monitor

693.2

2211.2

NT16

NOTES

Dimensions as noted are nominal and based on architectural construction documents. Full, as built, site measure prior to construciton required to ensure accurate length and radius dimensions for graphic ribbon joinery. Any discrepencies with nominal dimensions as drawn here to be discussed with Designer. Exact dimensions of graphic ribbon to be provided to designer for graphic art work to ensure fit.

Shadowlines at all intersections have been drawn at 9mm width to allow for a requried shadowline plus tolerances. A minimum of 6mm and a maximum of 12mm shadowline is required. Accurate site measure prior to fabrication should ensure this. Any discrepencies beyond these tolerances must be discussed with Designer.

Shadowline spacer height and location relative to graphic ribbon as drawn in elevation. Shadowline spacer depth 13mm from face of graphic ribbon. Spacer to be painted NT16

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 50

2NAEICShire of Northam

D367

CW CM 01/11/17

Graphic Ribbon Section1 & 2 J6.12

1 : 50J6.12Joinery Graphic Ribbon 1 & 21

1 : 50J6.12Graphic Ribbon A2

1 : 50J6.12Graphic Ribbon B3

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 22: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

9

shadowline both sides

2400 window9

3J6.13

3J6.13

2J6.13

9 1200 9

9 sha

dowl

ine

2452

371

Showcase by others Showcase by others

Grap

hic rib

bon 0

3

Graphic ribbon 04

724

Graphic ribbon 05

724

912009

Graphic ribbon 06

AC_01

AC_02

shao

wline

heigh

t

1230

shadowline9 mm

1200123418

2480 NOM. Curve COS

start

of cu

rve

Acrylic insertAC01

NT16

Acrylic insertAC02

butt join at intervals18 688 18

1812

3018

18 688 18

Window

showcaseby others

showcaseby others

NOTES

Dimensions as noted are nominal and based on architectural construction documents. Full, as built, site measure prior to construciton required to ensure accurate length and radius dimensions for graphic ribbon joinery. Any discrepencies with nominal dimensions as drawn here to be discussed with Designer. Exact dimensions of graphic ribbon to be provided to designer for graphic art work to ensure fit.

Shadowlines at all intersections have been drawn at 9mm width to allow for a requried shadowline plus tolerances. A minimum of 6mm and a maximum of 12mm shadowline is required. Accurate site measure prior to fabrication should ensure this. Any discrepencies beyond these tolerances must be discussed with Designer.

Shadowline spacer height and location relative to graphic ribbon as drawn in elevation. Shadowline spacer depth 13mm from face of graphic ribbon. Spacer to be painted NT16

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 50

2NAEICShire of Northam

D367

CW CM 01/11/17

Graphic Ribbon Section3, 4, 5 J6.13

1 : 50J6.13Joinery Graphic Ribbon 3, 4 & 51

1 : 50J6.13Graphic Ribbon 032

1 : 50J6.13Graphic Ribbon 04 & 053

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 23: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

15009

3857

Showcase by others

18 9

3J6.14

229671716341518 18 1624 1846

171616244055 NOM.

135.00°

Graphic Ribbon 06 Graphic Ribbon 07

Graphic Ribbon 08

4J6.14 AC_04

AC_03

C L

9647

717

565

18

760

9

Graphic ribbon 06

Curved COS 71618

9 1500 9

top rail

1518 2352 2296

showcaseby others

9 shadowline

18 965 18 1277 206218 18 1482 18

4472 NOM.

butt join at intervals

Acrylic caseAC03

Upright

butt join at intervals

NT16

Graphic Ribbon wrap to wall

NT16NT18

showcaseby others

2059 1995

18

9mm shadowline

acrylic caseAC04

butt join at intervals

NT18

NOTES

Dimensions as noted are nominal and based on architectural construction documents. Full, as built, site measure prior to construciton required to ensure accurate length and radius dimensions for graphic ribbon joinery. Any discrepencies with nominal dimensions as drawn here to be discussed with Designer. Exact dimensions of graphic ribbon to be provided to designer for graphic art work to ensure fit.

Shadowlines at all intersections have been drawn at 9mm width to allow for a requried shadowline plus tolerances. A minimum of 6mm and a maximum of 12mm shadowline is required. Accurate site measure prior to fabrication should ensure this. Any discrepencies beyond these tolerances must be discussed with Designer.

Shadowline spacer height and location relative to graphic ribbon as drawn in elevation. Shadowline spacer depth 13mm from face of graphic ribbon. Spacer to be painted NT16

930

8

18965 NOM.18

30

Align edge with graphic ribbon to right

16mm baseboard for graphic application

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Graphic Ribbon 6,7 & 8 J6.14

1 : 50J6.14Joinery Graphic Ribbon 61

1 : 50J6.14Graphic Ribbon 062

1 : 50J6.14Graphic Ribbon 073

1 : 25J6.14Graphic ribbon wrap to wall4

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 24: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

2J6.15

2126

2253

Graphic Ribbon 08

5302

3J6.15

2400

2601

Graphic Ribbon 09

3777

5J6.15

6J6.15

End panel attachedto structure withbiscuits or dowels

316

1266

18 70 9

18mm MDF cnc cut

bracing cnc cut to form curve

9mm bendy MDF or plyfor graphic application

2 layers 9mm bendy mdf or bendy ply on curves

18mm MDF cnc cut

bracing cnc cut to form curve

bracing as necessary to ensurestrucutral integrity

316

NT16

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Graphic Ribbon 9&10Detail on curves J6.15

1 : 50J6.15Joinery Graphic Ribbon 91

1 : 50J6.15Graphic Ribbon 082

1 : 50J6.15Graphic Ribbon 093

1 : 50J6.15Joinery Graphic Ribbon 104

1 : 10J6.15Detail Graphic ribbon5

1 : 10J6.15Detail Graphic Ribbon on curve6

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 25: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

Bulkhead above2J 6.16

3J 6.16

50

356

2627 50

9mm shadowline in front

7612 249

7861

9mm shadow lineNT16

2400

50

1OB_13

lower CL

high CL

Ring UC

Backing panel thickness to align with face of adjacent steel backing

FFL12

30NT16NT16

Magnetic steel plate

5194

FFL50mm

Internal bracing to the floor as required

5mm shadowline

843

2090

5mm shadowline

Hooks by others.

Graphic (by others) direct stick to backing panel and magnetic steel plate

NT16

NT16

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Conclusion J 6.16

1 : 50J 6.16Plan Conclusion Wall1

1 : 50J 6.16Conclusion Wall2

1 : 20J 6.16Section Conclusion Wall3

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 26: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

1.0 Welcome Immersive SpaceMM 1.1 ENTRY

MM 4.3

MM 4.2

MM 4.1

MM 2.1

MM 2.3

MM 2.2

MM 3.1

MM 3.2

M5.1

A_01

3.0 Boornaro

4.0 Djerrang

5.0 Malygaro

6.0 Djilyba

7.0 Gambarrang

8.0 Yarning Circle

9.0 Nyorn

A_02

A_03

A_04

A06

A09

A08A13

A12

A11

A15 A14

3.0 Biirdag

A07

7J6.18

8J6.18

6J6.18

Refer J6.18 for Audio station construction

Refer J7.05, J7.06 & J7.07 for monitor mounts

Refer J6.03 for M5.1 Map touch table

NOTE: JOINER AND GRAPHICS CO-ORDINATIONAll acrylic for graphic inserts and lightbox panels to be cut by joiner and supplied to graphics contractor. Graphics contractor to returnsame with graphics applied to allow joiner to fitinto joinery. Allow appropriate time for process.

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 100

2NAEICShire of Northam

D367

CW Checker 01/11/17

Plan Media J6.171 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 27: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

3J6.18

4J6.18

Audio ID Identifier screw fixedas manufacturers specifications

CNC route rebate 12mm deep for10mm acrylic graphic(by others). CNC file supplied by designer

Audio ID Identifier 10mm Acrylic graphicby others

2mm tape12

10J6.18

9J6.18

282

574

408

483

Dashed line indicates 400 x 800single sided lightpanel as specified rebated and mounted from underside top

Audio ID Identifier 10mm Acrylic graphic

2mm tape

CNC route rebate for 10mm Graphic on 10mm acrylic

Power from lightpanelthrough solid top

NT22 Single sided Lightpanel as specified CNC route underside of top to mount

Fix lightpanel to joinery with removable fixings for future access

NOTE: JOINER AND GRAPHICS CO-ORDINATIONAll acrylic for graphic inserts and lightbox panels to be cut by joiner and supplied to graphics contractor. Graphics contractor to returnsame with graphics applied to allow joiner to fitinto joinery. Allow appropriate time for process.

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Audio stations J6.18

1 : 50J6.18Audio Station2

1 : 10J6.18Joinery 02 Audio - Callout 13

J6.18Audio Stations1

1 : 10J6.18Section 3 Audio station4

1 : 50J6.18A08 Audio with lightbox6

J6.18Audio station with lightbox5

1 : 10J6.18Audio with lightbox - Callout 110

1 : 10J6.18Section Audio station and lightbox9

1 29/09/17 For Tender Draft2 01/11/17 For Tender

1 : 50J6.18A06 Audio statio with lightbox7

1 : 50J6.18A13 Audio station with lightbox8

AUDIO STATIONS AUDIO STATIONS WITH LIGHTBOXES

Page 28: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

NT13

NT24

NT13

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Entry sign J6.191 29/09/17 For Tender Draft2 01/11/17 For Tender

1 : 50J6.19Title panels and treatments1

Page 29: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

5J7.014

J7.01

2J7.01

along

all s

traigh

t elev

ation

s

Brac

ing flo

or to

unde

rside

top

along all straight elevations

Bracing floor to underside top

3J7.01

to unde

rside to

p

Bracing

floor

Champher (3mm) all edges and corners less than 90 degree

18mm MDF

12mm MDF to form shadowline

Fix front to top -paint out fixture

Solid timber top

17mm shadowline

Bracing to floor to support top

50 100

100

30

Vertical bracing as required

12 Fix to bracing

5J7.01

Removable panel

850

5075

347

2 x 9mm Bendy MDF

Kick formed from 2 x 9mm BendyMDF to internal face Frame

Frame 25mm MDF cnc cutfrom plan dwg

Frame 25mm MDF cnc cutbased on plan dwg

Locator 25mm to underside top. Allow gap for timber movement

NT21 - LED strip lighting

Top placed over frame.Fixed at straight elevations only

2J7.08

fix to locator. Paint all exposed fixing headsBendy ply

Removable panel

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Detail constructionJoinery units J7.01

1 : 20J7.01Construction detail Joinery untis1

1 : 10J7.01Detail straight edge fixing5

1 : 20J7.01Elevation End panel2

1 : 10J7.01Detail curved edge fixing4

1 : 20J7.01Elevation End panel 023

NOTES All corners/ edges less than 90 degrees to be champhered 3mm Allow appropriate tolerances for movement of timber to fixings between solid timber top and MDF structure and face panelsAll vertical corners mitred except where a removable panel

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 30: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

18mm MDF

Basebuild wall by others

Graphic on 3mm simona (byothers) adhered to mdf.Ensure fully smooth finish

9mm mdf substrate.(9mm bendy mdf on curves)to be applied after structureis fixed to wall or battens

18mm mdf on straight

18mm MDF

2 layers 9mm bendy mdf on curves

Ply b

racin

g strip

by ba

sebu

ilt

1190

Bracing structureCNC cut on corners

2J7.02

219

97

9 mm shadowline/ spacer

uprights positioned for both structural reasonsand between graphic panels

1870

9

Uprights located as dimensioned. Discrepancies between drawings and site measure to be discussed with designer

EQ EQ EQ EQ EQ

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 10

2NAEICShire of Northam

D367

CW CM 01/11/17

Detail ConstructionGraphic Ribbon J7.02

1 : 10J7.02Construction detail2

1 : 10J7.02Graphic Ribbon Plan detail1

Graphic on 3mm simona (byothers) adhered to mdf.Ensure fully smooth finish

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 31: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

18 595 18 99

J7.03

2

4J7.03 Showcase by others

Lightbox

315

100

1210

3J7.03

4J7.03

Indicative onlyof graphic cut out.Artwork supplied

as cnc file forcutting

NT13

NT8

NT8

1820

1418

40

9mm shadow betweenlightbox and showcase

9mm shadow betweenlightbox and graphic ribbon

NT13 on 18mm MDFGraphic cut out with black edge. cnc file suppied by designer

Face of lightbox 10mm acrylic NT18

power throughwall

40

Top of graphic ribbon

NT25 LED lighting as specified on backing board 18mm MDF . Ensure consistancy oflight in all visible areas

12

Allow for blocking and structure to areas withno cut out in veneeredsurface

18mm MDF base

No visible framing through cut out pattern.Ensure front face and acrylic front to lightbox is removable to acccess LED lights

100

122

70mm cavity between inside face acrylic and backboard with LED ligting

3J7.03

NOTE: JOINER AND GRAPHICS CO-ORDINATIONAll acrylic for graphic inserts and lightbox panels to be cut by joiner and supplied to graphics contractor. Graphics contractor to returnsame with graphics applied to allow joiner to fitinto joinery. Allow appropriate time for process.

4J7.03

NT25

56979797979756

RLOCAL

DIM

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Detail ConstructionLightbox interactive J7.03

1 : 10J7.03Detail Showcase and Interactive1

1 : 10J7.03Elevation Interactive2

1 : 10J7.03Section Lightbox4

1 29/09/17 For Tender Draft2 01/11/17 For Tender

1 : 10J7.03Section showing LED placement3

TYPE 'R' - 12454mm CHAIN LENGTH OFWARM WHITE LED's BACKLIGHTINGACRYLIC DIFFUSER - 10mm MINIMUMTHICKNES. 155 BEAM ANGLE OF EACH LED.

NAEIC LIGHTBOX LIGHTING LAYOUTDATE 6.11.17 ILLUMINATED DESIGN

NOT FOR CONSTRUCTION

Page 32: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

3

J7.04

NT19 security

screws

NT19 security

screws

1670

9

16mm MDF fixed to graphic

ribbon to locate acrylic

upright and lock to,

2mm tolerance to all sides

Allow 1mm tolerance either

side acrylic

Graphic (by others) adhered

and wrapped to mdf.

J7.04

2

Ext

erna

l hei

ght a

s sc

hedu

led

External Width as scheduledACRYLIC 3 SIDED CASES

212

262

NT16

NT07

external width as scheduled

NT18

NT19

external depth as scheduled

ACRYLIC 3 SIDED CASE

Showcase External External External

Code Height Width Depth

AC_02 1226 400 221

AC_04 1226 717 221

Code Height Width QTY standoffs

AC_01 1226 717 4

AC_03 1226 717 4

ACRYLIC GRAPHICS (supplied by others.)

Fixed to graphic ribbon with FIX FX25 CSP 100mm body standoff)

ACRYLIC GRAPHICS fixed with standoffs

112

281

717

NOTE: JOINER AND GRAPHICS CO-ORDINATIONAll acrylic for graphic inserts and lightbox panels to be cut by joiner and supplied to graphics contractor. Graphics contractor to returnsame with graphics applied to allow joiner to fitinto joinery. Allow appropriate time for process.

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT

As indicated

2NAEIC

Shire of Northam

D367

CW CM 01/11/17

Acrylic cases in GraphicRibbon and Standoffs J7.04

1 : 10J7.04

Detail Acrylic box1

1 : 10J7.04

Elevation Acrylic box2

1 : 10J7.04

Section Acrylic box3

1 29/09/17 For Tender Draft

2 01/11/17 For Tender

Page 33: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

245

95

30

30

MO

NIT

OR

122

2

1250

MONITOR 693.2

722

B

A

MONITOR 31.3

400X

400

VE

SA

MO

UN

T

360.

5 A

LIG

N T

O F

LOO

R P

EN

ET

RA

TIO

N

C

MONITOR + 5 mm SHADOWLINETO FRAME

RHS 75 x 25 x 2.5 FULLYWELDED SQUARE TOBASE PLATE AND U.E.

10mm PLATE WITH CONTINUOUS 10mm RADIUS TO 4SIDES; 4 X 8mm DIA COUNTERSUNK MASONRYFASTENERS POWDERCOAT FINISH TO MATCH STEELCOMPONENTS

SECTION A BASEPLATE DETAIL 1:10

ALLOW FOR CONDUITPENETRATIONTHROUGH BASEPLATE

REAR ELEVATION 1:10

FRONT ELEVATION 1:10

SECTION B 1:10

75x50x6 RHS

VESA MOUNT

RHS 75 x 50 x 6

3mm PERFORATEDALUMINIUM SHEET9.50 DIA X12.70 CENTRESPOWDERCOATED

SECTION C1:10

75x50x6 RHS

RHS 75 x 25 x 2.5

40EA5

75X6 FLAT PERIMETER TRIM

TIMBER BATTEN

40 X 40 X 6 TAB

MONITOR

RHS 75 x 50 x 6BRACE TO TIMBERBATTEN

NOTE : ALL COMPONENTSPOWDERCOAT FINISH

ALLOW FOR CABLES TOPENETRATE FORCONNECTION TOMONITOR

NOTE: Monitor dimesnions may change co-ordinate with AV hardwarecontractor

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 10

2NAEICShire of Northam

D367

MB CM 01/11/17

Freestanding MonitorMount J 7.05

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 34: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

MO

NIT

OR

122

2

MONITOR 693.2

722

B

MONITOR 31.3

400X

400

VE

SA

MO

UN

T

115

VESA MOUNT

C

REAR ELEVATION 1:10

SECTION B 1:10

VESA MOUNT

3mm PERFORATEDALUMINIUM SHEET9.50 DIA X12.70 CENTRESPOWDERCOATEDFASTENED TO 25EA3SUPPORT RAILS

SECTION C1:10

RHS 75 x 25 x 2.5WELD TO PERIMETRE FLATAND OFFSTAND BRACKET

40EA5

75X6 FLAT SIDE TRIM

MONITOR

NOTE : ALL COMPONENTSPOWDERCOAT FINISH

FASTEN THROUGH TOBRACING STRUCTUREBEHIND PLY

18MM MDF GRAPHICRIBBON STRUCTURE

400X 400 X 6MMMOUNTING PLATE FULLYWELDED TO RHS

RHS 75 x 50 x 6 OFFSTAND

SIDE ELEVATION1:10

25EA3 PERFORATEDPANEL SUPPORT RAILS

25EA3 PERFORATEDPANEL SUPPORT RAILS

NOTE: Monitor dimesnions may change co-ordinate with AV hardwarecontractor

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 10

2NAEICShire of Northam

D367

MB CM 01/11/17

Graphic Ribbon MonitorMount J 7.06

1 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 35: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

MO

NIT

OR

122

2

MONITOR 693.2

722

B

MONITOR 31.3

400X

400

VE

SA

MO

UN

T

115

VESA MOUNT

316

97018

C

REAR ELEVATION 1:10

SECTION B 1:10

VESA MOUNT

SECTION C1:10

RHS 75 x 25 x 2.5WELD TO PERIMETRE FLATAND OFFSTAND BRACKET

40EA5

75X6 FLAT SIDE TRIM

MONITOR

NOTE : ALL COMPONENTSPOWDERCOAT FINISH

FASTEN THROUGH TOBRACING STRUCTUREBEHIND PLY

400X 400 X 6MMMOUNTING PLATE FULLYWELDED TO RHS

RHS 75 x 50 x 6 OFFSTAND

25EA3 PERFORATEDPANEL SUPPORT RAILS

25EA3 PERFORATEDPANEL SUPPORT RAILS

150mm TIMBER BATTEN

SCREW FIX THROUGHSTRUCTURE TO EVERY150MM BATTEN PRIOR TOFIXING 9MM MDF

NOTE: Monitor dimesnions may change co-ordinate with AV hardwarecontractor

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENT 1 : 10

2NAEICShire of Northam

D367

MB CM 01/11/17

Batten Monitor Mount J 7.071 29/09/17 For Tender Draft2 01/11/17 For Tender

Page 36: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

MM2.1

MM2.2

MM2.3

3424 1155

947

1246

31031210

1503

2291

1872

2154

2495

1300

PT

RPT

T

T

P

PS

P

PP

P

S

S

N

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM

LOCALDIM LOCAL

DIMLOCAL

DIMLOCAL

DIMLOCAL

DIM LOCALDIM

NT21 - LED strip lightingside emitting as specified

5025

25

100

N CONCEALED MINITURE TRACK W/4W MINIATURE TRACK MOUNTED SPOTLIGHTS. WARM WHITE LED. LOCAL DIMMING

P CONCEALED LED SKIRTING LIGHT W/10W/M WARM WHITE LED LOCALLY DIMMED SEE DETAIL

R BACKLIT LIGHTBOX SEE DETAIL 33.8W 12V 3000K WARM WHITE DIMMABLE 1- 100% LOCALLY

S CUSTOM LIGHT PANEL INTEGRATED INTO JOINERY - SEE DETAIL

T CUSTOM LIGHT PANEL INTEGRATED INTO BASEBOARD OF TABLE SHOWCASES - SEE DETAIL

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 29/09/17

Joinery & ShowcaseLighting Plan J7.08

1 : 100J7.08Floor Plan Lighting layout1

1 : 5J7.08Detail LED strip lighting2

1 29/09/17 For Tender Draft2 01/11/17 For Tender

NAEIC FLOOR PLAN LIGHTING LAYOUTDATE 6.11.17 ILLUMINATED DESIGN

NOT FOR CONSTRUCTION

Page 37: TENDER DOCUMENTATION - NOT FOR CONSTRUCTION JOINERY PACKAGE 1 … · 2019-06-13 · PO BOX 760, Queanbeyan, 2620 Canberra p: 02 6299 7340 e: canb@thylacine.com.au PROJECT / CLIENT

3J 6.16

MIRROR DIRECT STICK TO PLY

6571 NOM.

align 10mm vertical shadowline with bulkhead above10mm vertical shadowline

2J 7.09

PLASTERBOARD OVER 12MM PLY

TYPE IW07

5J 7.09

100

wal

l kic

k

1691

6MM MIRROR DIRECT STICK TO PLY

joint joint

IW07

MIR

RO

R

3660

6mm mirror direct stick to 12mm plyskirting to base

p50 shadowline 13mm PB

PO BOX 760, Queanbeyan, 2620Canberrap: 02 6299 7340e: [email protected]

PROJECT / CLIENT PROJECT No. SCALE

DATEDRAWN CHECKED

DRAWING TITLE DRAWING NUMBERREVISIONREV DATE AMENDMENTAs indicated

2NAEICShire of Northam

D367

CW CM 01/11/17

Mirrored wall J 7.09

1 : 50J 7.09Mirrored wall1

1 : 50J 7.09Elevation Mirrored wall2

1 29/09/17 For Tender Draft2 01/11/17 For Tender

1 : 10J 7.09Wall Detail Mirror4

1 : 5J 7.09Mirrored wall - Callout 15

6mm mirror direct stick to 12mm plywood

100mm high mdf skirting shadowline detail at junction paint finish