Temporary Structure Drawing Package Sample
3130
3130
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A31 : 150
Elevations
Author Checker
.
1 : 150Front Elevation1
1 : 150Rear Elevation2
1 : 150Left Elevation31 : 150
Right Elevation4
B
C
D
E
F
3 4 5 6
Stub legs
Steel levelling foot
Stub leg clamps
7 9 10
For kentlege requirementssee Structural EngineersCalculation Sheets
G
H
I
J
K
L
12 13 14 15 16
A
1
N
11Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
Stubs
Author Checker
.
1 : 100Stub Legs1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Sleeper beams
Grid beams
Floor panels
B
C
D
E
F
3 4 5 6 7 9 10
G
H
I
J
K
L
12 13 14 15 16
1200
060
00
A
3000
24000
1
N
11
3000
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
Ground Platform
Checker
.
1 : 100Ground Platform1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Vertical columns
Bracing
Mullions
Intermediate columns
B
C
D
E
F
3 4 5 6 7 9 10
G
H
I
J
K
L
12 13 14 15 16
1200
0
A
1
N
up
upup
11
4000 6000
6000 4000 4000 4000 6000
24000
3000
18000
8000
2000
8000
3000 2000 4000
Han
drai
lsIn
fills
by
clie
nt
HandrailsInfills by client
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
Ground Frame
Checker
.
1 : 100Ground Frame1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Solid walls
B
C
D
E
F
3 4 5 6 7 9 10
Double doors
Hinged doors
G
H
I
J
K
L
12 13 14 15 16
A
1
N
11
Tinted glass walls
Solidwalls
Fire exit door
Single door
Solid walls Solid walls
Solidwalls
Sol
idw
alls
Sol
idw
alls
Sol
idw
alls
Sol
idw
alls
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
Ground Walls
Checker
.
1 : 100Ground Walls1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Floor panels
Main beam
Truss beam
Space beam
B
C
D
E
F
G
H
I
J
K
L
A
N
Sleeper beam
4000
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
1st Platform
Author Checker
.
1 : 1001
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
2
B
C
D
E
F
G
H
I
J
K
L
N
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
1st Frame
Author Checker
.
1 : 1001st Frame1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
B
C
D
E
F
3 4 5 6 7 9 10
Solid walls
Solid walls
G
H
I
J
K
L
12 13 14 15 16
A
1
N
11
Handrails
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
1st Walls
Author Checker
.
1 : 1001st Walls1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
2734
3000
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 75
2nd Platform
Author Checker
.1 : 752nd Platform1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Main &gutter beams
Roof skin
Roof braces
B
C
D
E
F
3 4 5 6
Roof poles/ bosses& brackets
7 9 10
G
H
I
J
K
L
12 13 14 15 16
A
1
N
11
Handrails
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
Roof
Checker
.
1 : 100Roof Level1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
Sections 1
20 Aug 10
Checker
.
1 : 100Section 44
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
3130
Gutter beam
Main beam
Ground floor level
First floor level
Main beam
Super Truss beam
Grid beam
Dim varies
Roof poles, bosses &brackets
Space bracing
3130
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 75
Sections 2
Author Checker
.
1 : 75Copy of Section 31
1 : 75Section 12
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
View Ground Frame
Author Checker
.
View Ground Frame1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
View First Frame
Author Checker
20F
.
View First Frame1
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
View Frames Gd & 1st
Author Checker
.
D 9 Nov 10Revised
F 22 Nov 10Revised
Copy (2) of View Ground Frame3
Copy of View First Frame4
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
Walls Ground View
Author Checker
.
Wall Panels Aerial View GD1
F 22 Nov 10Revised
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
Walls First View
Author Checker
.
Wall Panels Aerial View 1st1
F 22 Nov 10Revised
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
2nd Floor View Terrace
Author Checker
.
View 2nd Floor Terrace1
F 22 Nov 10Revised
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
Views
Checker
.
Aerial Front1
Aerial Rear2
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
18 Tread staircasesB
C
D
E
F
3 4 5 6
up
7 9 10
up
Hinged doors
Cross bracing
G
H
I
J
K
L
12 13 14 15 16
A
1
N
11
Fire exit
1500
0
1200
0
24000
6000 18000
up
up
Fire exit
Door
3000
Solid walls
Tinted glass walls
Solidwalls
Solid walls Solid walls
Solidwalls
Sol
idw
alls
Sol
idw
alls
Sol
idw
alls
Sol
idw
allsG1 G2 G3 G4
G5 G6
Han
drai
lsIn
fills
by
clie
nt
HandrailsInfills by client
3000 2000 4000
8000
2000
8000
3000
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
GA Ground Floor
Checker
.
1 : 1001
A - 24 Aug Revised
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised
Vertical columns
Mullions
Intermediate columns
Bracing
Handrail to stairwell
B
C
D
E
F
3 4 5 6 7 9 10
down
G
H
I
J
K
L
12 13 14 15 16
A
1
N
11
up
1200
030
00
6000 18000
6000
Terrace
Handrails
up
down
F1
F2
F3 F4 F5 F6
F8
F7
Solid walls
Solid walls
Wall by client
1870
1870
1870
Checked by:Drawn
Date:
Project number:
Level dimensions are given in good faith, are approximateand may vary due to site conditions.
Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.
Drawing no:
Scale @ A3
no: date: description:
1 : 100
GA 1st Floor
Author Checker
.
1 : 100GA 1st Floor1
A - 24 Aug Revised
B 28 Sept 10Rear stairs added
C 4 Oct 101st floor beams & floorboards revised
D 9 Nov 10Revised
E 10 Nov 10Revised
F 22 Nov 10Revised