Temporary Structure- Drawing Package Sample from Condit Exhibits

22
temporary structures and event services… Temporary Structure Drawing Package Sample

description

At Condit Exhibits, we deliver innovative temporary structures that are at the cutting edge of semi-permanent building technology. Learn more about the drawing packages of our designs and the amazing spaces we create.

Transcript of Temporary Structure- Drawing Package Sample from Condit Exhibits

Page 1: Temporary Structure- Drawing Package Sample from Condit Exhibits

temporary  structures  and  event  services…  

Temporary  Structure  Drawing  Package  Sample      

Page 2: Temporary Structure- Drawing Package Sample from Condit Exhibits

3130

3130

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A31 : 150

Elevations

Author Checker

.

1 : 150Front Elevation1

1 : 150Rear Elevation2

1 : 150Left Elevation31 : 150

Right Elevation4

Page 3: Temporary Structure- Drawing Package Sample from Condit Exhibits

B

C

D

E

F

3 4 5 6

Stub legs

Steel levelling foot

Stub leg clamps

7 9 10

For kentlege requirementssee Structural EngineersCalculation Sheets

G

H

I

J

K

L

12 13 14 15 16

A

1

N

11Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

Stubs

Author Checker

.

1 : 100Stub Legs1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 4: Temporary Structure- Drawing Package Sample from Condit Exhibits

Sleeper beams

Grid beams

Floor panels

B

C

D

E

F

3 4 5 6 7 9 10

G

H

I

J

K

L

12 13 14 15 16

1200

060

00

A

3000

24000

1

N

11

3000

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

Ground Platform

Checker

.

1 : 100Ground Platform1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 5: Temporary Structure- Drawing Package Sample from Condit Exhibits

Vertical columns

Bracing

Mullions

Intermediate columns

B

C

D

E

F

3 4 5 6 7 9 10

G

H

I

J

K

L

12 13 14 15 16

1200

0

A

1

N

up

upup

11

4000 6000

6000 4000 4000 4000 6000

24000

3000

18000

8000

2000

8000

3000 2000 4000

Han

drai

lsIn

fills

by

clie

nt

HandrailsInfills by client

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

Ground Frame

Checker

.

1 : 100Ground Frame1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 6: Temporary Structure- Drawing Package Sample from Condit Exhibits

Solid walls

B

C

D

E

F

3 4 5 6 7 9 10

Double doors

Hinged doors

G

H

I

J

K

L

12 13 14 15 16

A

1

N

11

Tinted glass walls

Solidwalls

Fire exit door

Single door

Solid walls Solid walls

Solidwalls

Sol

idw

alls

Sol

idw

alls

Sol

idw

alls

Sol

idw

alls

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

Ground Walls

Checker

.

1 : 100Ground Walls1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 7: Temporary Structure- Drawing Package Sample from Condit Exhibits

Floor panels

Main beam

Truss beam

Space beam

B

C

D

E

F

G

H

I

J

K

L

A

N

Sleeper beam

4000

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

1st Platform

Author Checker

.

1 : 1001

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

2

Page 8: Temporary Structure- Drawing Package Sample from Condit Exhibits

B

C

D

E

F

G

H

I

J

K

L

N

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

1st Frame

Author Checker

.

1 : 1001st Frame1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 9: Temporary Structure- Drawing Package Sample from Condit Exhibits

B

C

D

E

F

3 4 5 6 7 9 10

Solid walls

Solid walls

G

H

I

J

K

L

12 13 14 15 16

A

1

N

11

Handrails

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

1st Walls

Author Checker

.

1 : 1001st Walls1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 10: Temporary Structure- Drawing Package Sample from Condit Exhibits

2734

3000

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 75

2nd Platform

Author Checker

.1 : 752nd Platform1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 11: Temporary Structure- Drawing Package Sample from Condit Exhibits

Main &gutter beams

Roof skin

Roof braces

B

C

D

E

F

3 4 5 6

Roof poles/ bosses& brackets

7 9 10

G

H

I

J

K

L

12 13 14 15 16

A

1

N

11

Handrails

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

Roof

Checker

.

1 : 100Roof Level1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 12: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

Sections 1

20 Aug 10

Checker

.

1 : 100Section 44

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 13: Temporary Structure- Drawing Package Sample from Condit Exhibits

3130

Gutter beam

Main beam

Ground floor level

First floor level

Main beam

Super Truss beam

Grid beam

Dim varies

Roof poles, bosses &brackets

Space bracing

3130

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 75

Sections 2

Author Checker

.

1 : 75Copy of Section 31

1 : 75Section 12

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 14: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

View Ground Frame

Author Checker

.

View Ground Frame1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 15: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

View First Frame

Author Checker

20F

.

View First Frame1

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 16: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

View Frames Gd & 1st

Author Checker

.

D 9 Nov 10Revised

F 22 Nov 10Revised

Copy (2) of View Ground Frame3

Copy of View First Frame4

Page 17: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

Walls Ground View

Author Checker

.

Wall Panels Aerial View GD1

F 22 Nov 10Revised

Page 18: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

Walls First View

Author Checker

.

Wall Panels Aerial View 1st1

F 22 Nov 10Revised

Page 19: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

2nd Floor View Terrace

Author Checker

.

View 2nd Floor Terrace1

F 22 Nov 10Revised

Page 20: Temporary Structure- Drawing Package Sample from Condit Exhibits

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

Views

Checker

.

Aerial Front1

Aerial Rear2

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 21: Temporary Structure- Drawing Package Sample from Condit Exhibits

18 Tread staircasesB

C

D

E

F

3 4 5 6

up

7 9 10

up

Hinged doors

Cross bracing

G

H

I

J

K

L

12 13 14 15 16

A

1

N

11

Fire exit

1500

0

1200

0

24000

6000 18000

up

up

Fire exit

Door

3000

Solid walls

Tinted glass walls

Solidwalls

Solid walls Solid walls

Solidwalls

Sol

idw

alls

Sol

idw

alls

Sol

idw

alls

Sol

idw

allsG1 G2 G3 G4

G5 G6

Han

drai

lsIn

fills

by

clie

nt

HandrailsInfills by client

3000 2000 4000

8000

2000

8000

3000

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

GA Ground Floor

Checker

.

1 : 1001

A - 24 Aug Revised

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised

Page 22: Temporary Structure- Drawing Package Sample from Condit Exhibits

Vertical columns

Mullions

Intermediate columns

Bracing

Handrail to stairwell

B

C

D

E

F

3 4 5 6 7 9 10

down

G

H

I

J

K

L

12 13 14 15 16

A

1

N

11

up

1200

030

00

6000 18000

6000

Terrace

Handrails

up

down

F1

F2

F3 F4 F5 F6

F8

F7

Solid walls

Solid walls

Wall by client

1870

1870

1870

Checked by:Drawn

Date:

Project number:

Level dimensions are given in good faith, are approximateand may vary due to site conditions.

Dimensions are given in good faith but may vary due tomanufacturing and assembly tolerances.

Drawing no:

Scale @ A3

no: date: description:

1 : 100

GA 1st Floor

Author Checker

.

1 : 100GA 1st Floor1

A - 24 Aug Revised

B 28 Sept 10Rear stairs added

C 4 Oct 101st floor beams & floorboards revised

D 9 Nov 10Revised

E 10 Nov 10Revised

F 22 Nov 10Revised