TEMP-AIR, Inc. - HVAC RENTAL SOLUTIONS · 2019. 11. 8. · TEMP-AIR rental equipment is...
Transcript of TEMP-AIR, Inc. - HVAC RENTAL SOLUTIONS · 2019. 11. 8. · TEMP-AIR rental equipment is...
HEATING | AIR MANAGEMENT | COOLING
PROUD TO BE MADE IN THE USA
H V A C R E N T A L S O L U T I O N S
1
About Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Direct-Fired Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Electric Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Indirect-Fired Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
Hydronic Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Steam / Hot Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . 12-13
Proudly Made In The USA . . . . . . . . . . . . . . . . . . . . . . . . . 14-15
Air-Cooled Portable Air Conditioners . . . . . . . . . . . . . . . . . . . 16
Air-Cooled Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Water-Cooled Portable Air Conditioners . . . . . . . . . . . . . . . . . 18
Cool Only Industrial Air Conditioners . . . . . . . . . . . . . . . . . . 19
Cool / Heat / Dehumidify Industrial Air Conditioners . . . . . . . . . . 20-21
Chillers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Air Handlers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Dehumidifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25
Air Filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
COOLING
AIR MANAGEMENT
HEATING
32
WHO WE AREOur company has over 50 years of experience in HVAC rental services provided throughout the United States. Our professional service staff delivers and sets up temporary heating, cooling, dehumidifying, and air filtration rental equipment at your job site. We are available 24/7 to meet your emergency temperature control needs by providing custom temporary air management solutions specifically for your unique job site.
OUR HISTORYIn the 1960s, our founder introduced the first mobile heater to a winter construction site allowing jobsites to begin to operate year-round. After excelling at the production of portable heaters for several decades, temporary air conditioners and dehumidifiers were added to TEMP-AIR’s portfolio in the mid-1990s. In the late-1990s, the Thermal Remediation® pest control heat treatment division of TEMP-AIR, Inc. was launched as a spin-off of the company’s construction portable heating business.
THE TEMP-AIR DIFFERENCETEMP-AIR rental equipment is manufactured in the United States at our 140,000 square foot corporate headquarters located just south of Minneapolis, Minnesota. Our in-house engineering team is responsive to industry changes, dedicated to providing quality products, and can customize equipment specific to your company’s specialized needs. TEMP-AIR equipment is available for rent through our 16 branch offices located throughout the nation allowing you to conveniently obtain your requested equipment as soon as possible. Our seasoned team will size and layout equipment at your project for maximum effectiveness and lowest overall project costs. Additionally, our emergency service team is prepared to help problem solve when you need it most.
SINCE 1965, TEMP-AIR, INC. HAS BEEN THE NATION’S LEADING PROVIDER OF TEMPORARY HEATING, COOLING, DEHUMIDIFYING, AND AIR FILTRATION RENTAL SERVICES.
www.temp-air.com | 800-836-7432
HEATINGwww.temp-air.com | 800-836-7432 5HEATING www.temp-air.com | 800-836-7432 4
THP-500
THP-1400
FEATURES• Electronic modulating burner controls• Remote space thermostats• Centrifugal blower
TEMP. -15˚OUTSIDE
MAKE-UP AIR FLOOR LEVEL 55˚
MID POINT 60˚
ROOF LEVEL 65˚
This is our most popular heater type for construction sites, providing warm, dry air to a space.
DIRECT-FIRED HEATERS
MODEL BTU/HR CFM POWER SUPPLYV/PH/HZ/A
NATURAL GAS PROPANE DIMENSIONS
L X W X H (IN)WEIGHT (LBS) BASE
THP-400 80,000 – 400,000 2,400 115/1/60/20 1″ NPT 0.5″ NPT 50 x 26 x 48 450 Casters
THP-500 40,300 – 500,000 2,800 115/1/60/20 1″ NPT 0.5″ NPT 59 x 26 x 65 560 Casters
THP-550 40,500 – 550,000 3,000 115/1/60/20 1″ NPT 0.5″ NPT 60 x 31 x 66 500 Casters
THP-750 43,200 – 750,000 4,000230/1/60/15230/3/60/6460/3/60/3
1″ NPT 0.5″ NPT 68 x 33 x 65 757 Casters
THP-1000 48,600 – 1,000,000 6,000230/1/60/25230/3/60/15460/3/60/7
1″ NPT 1″ NPT 76 x 35 x 69 939 Casters
MODEL BTU/HR CFM POWER SUPPLYV/PH/HZ/A
NATURAL GAS PROPANE DIMENSIONS
L X W X H (IN)WEIGHT (LBS) BASE
THP-1400 60,750 – 1,400,000 7,600230/1/60/25230/3/60/15460/3/60/7
1.25″ NPT 1″ NPT 87 x 35 x 51 1,197 Casters
THP-2000 89,100 – 2,000,000 11,000230/1/60/35230/3/60/20460/3/60/10
1.25″ NPT 1″ NPT 106 x 46 x 46 1,607 Skid
THP-3000 133,650 – 3,000,000 16,500 230/3/60/30460/3/60/15 1.5″ NPT 1″ NPT 123 x 58 x 64 2,633 Skid
THP-4000 170,000 – 4,000,000 21,000 230/3/60/40460/3/60/20 2″ NPT 1″ NPT 134 x 60 x 73 2,700 Skid
THP-4500 202,500 – 4,500,000 24,500 230/3/60/60460/3/60/30 2″ NPT 1″ NPT 125 x 68 x 66 3,192 Skid
THP-SERIESDirect-fired make-up air heaters work well in most types of construction applications, helping to control moisture and air contaminants. Make-up air is air from the outdoors that is heated and then evenly distributed indoors in a controlled manner to replace air that is being exhausted. Installed either inside or outside, THP-series heaters draw 100-percent fresh air through the unit’s intake and discharge tempered air controlled bya remote thermostat. These heaters operate similar to a permanent air handler, providingevenly distributed warm, dry air into a space.
THP-4500
HEATINGwww.temp-air.com | 800-836-7432 7HEATING www.temp-air.com | 800-836-7432 6
CH-300
CH-SERIESCH-series construction heaters are designed for portability and versatility with high discharge temperatures and comparatively lower fan induction ratios. These direct-fired heaters work well in loose enclosures such as under concrete deck pours, masonry enclosures, and spot heat situations. This series is ideal for sites where 115V power is available. These compact units contain remote thermostats which automatically cycle from low to high fire to maintain the desired space temperature. A control exists on the unit to verify proper air-flow before ignition can take place.
FEATURES• Electronic flame supervision• Proof-of-air-flow control • Remote thermostat• Fork lift pockets• High temperature limit
This portable heater series works well to provide spot heating on construction sites.
DIRECT-FIRED HEATERS
MODEL BTU/HR CFM POWER SUPPLYV/PH/HZ/A
NATURAL GAS PROPANE DIMENSIONS
L X W X H (IN)WEIGHT (LBS) BASE
CH-300 150,000 – 300,000 1,700 115/1/60/10 1″ NPT 0.5″ NPT 41 x 12 x 21 86 Skid
CH-600 300,000 – 600,000 3,000 115/1/60/15 1″ NPT 0.5″ NPT 55 x 20 x 43 445 Casters
CH-1000 500,000 – 1,000,000 6,000 115/1/60/20 1″ NPT 0.5″ NPT 61 x 24 x 49 330 Casters
CH-1500 750,000 – 1,500,000 7,000 115/1/60/20 1″ NPT 1″ NPT 61 x 32 x 48 378 Casters
ETHP-150HS
ETHP-SERIESElectric heaters are ideal for jobsites where gas is not available or where flameless operations are necessary. Accessibility to high voltage and amperage power are required to run this type of heater. ETHP-series temporary heaters work well in confined spaces since they do not produce combustion emissions. Built-in digital temperature controls provide precise measurement of space and discharge temperatures while the thermostat automatically adjusts temperature output. The proof-of-air-flow control senses obstructed air intake and prevents coil from energizing.
FEATURES• Digital temperature controls• Proof-of-air-flow controls• Built-in circuit breakers• Remote thermostats• Available on casters for portability
ELECTRIC HEATERSThese heaters are ideal for jobsites where no gas is available or where flameless operations are required.
MODEL OUTPUT KW/HR CFM POWER SUPPLY
V/PH/HZ/AESP*(IN)
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE
ETHP-10-2 10 1,070 230/1/60/45 24 x 23 x 34 65 Casters
ETHP-15-2 15 1,070 230/3/60/40 23 x 28 x 34 65 Casters
ETHP-15-4 15 1,070 460/3/60/20 23 x 28 x 34 65 Casters
ETHP-20-4 20 1,070 460/3/60/30 23 x 28 x 34 75 Casters
ETHP-30-4 30 1,070 460/3/60/40 23 x 28 x 34 75 Casters
ETHP-60-4 60 1,100 – 2,700 460/3/60/75 44 x 30 x 39 170 Casters
ETHP-100 100 2,100 460/3/60/150 59 x 26 x 49 624 Casters
ETHP-150 150 4,000 460/3/60/200 69 x 32 x 65 1,152 Casters
ETHP-150A 150 5,000 460/3/60/200 1 78 x 35 x 72 1,250 Casters
ETHP-150HS 150 1,600 – 3,300 460/3/60/200 6 73 x 32 x 47 1,174 Casters
*ESP = External Static Pressure in Inches Water Column
CH-1000 ETHP-15-4
ETHP-60-4CH-300
HEATINGwww.temp-air.com | 800-836-7432 9HEATING www.temp-air.com | 800-836-7432 8
MIDFO-SERIESThe trailer-mounted MIDFO-series of indirect-fired heaters are a great all-in-one option for the temporary heating of remote jobsites. This turnkey mobile heating system contains an on-board diesel fuel tank with a run time up to 28 hours. There is no need to worry about having sufficient external power available at the jobsite as the unit contains a built-in 10kW generator. This turnkey heating solution is ideal for the following applications: oil wells, wind towers, bridge construction, temporary facilities, tents, and structural drying for flood restoration.
FEATURES• Easy to pull self-contained trailer unit• Automated controls with exterior lights • Large capacity on-board fuel tank• On-board storage for ductwork• Contains built-in generator
MODEL HEAT CAP. BTU/HR
AIR DELIVERY
ON-BOARD GENERATOR
FUEL TYPE
TANK CAP. (GALLONS)
RUN TIME
AIR DISTRIBUTION
DIMENSIONS L X W X H (IN)
WEIGHT (LBS)
MIDFO-800 (1) 800,000 4,000 CFM 10 kW Diesel 200 28 Hours Two – 16″ Collars
Ductable up to 100' 201 x 81 x 108
5,600 No Fuel
7,000 Full Fuel
MIDFO-1100 (2) 400,000 11,000 CFM Total 10 kW Diesel 180 28 Hours Two – 20″ Collars
Ductable up to 100' 208 x 96 x 84
5,500 No Fuel
6,800 Full Fuel
INDIRECT-FIRED HEATERSThis type of heater provides heat similar to a home furnace with zero products of combustion entering the space.
FEATURES• Multiple fuel options are available• Stainless steel combustion chamber• Thermostatically controlled for
fuel efficiency
IDF-SERIESIndirect-fired heaters are typically installed outside a structure with ductwork drawing the heated air inside the facility. This heater type works similarly to a home furnace by forcing outside air through a heat exchanger and into the space while diverting products of combustion outside of the space through a chimney. The IDF-series of indirect-fired heaters are recommended for cleanroom projects for pharmaceutical manufacturing, medical device manufacturing, and other industrial applications where maintaining a controlled environment is crucial.
MODEL BTU/HR INPUT
BTU/HR OUTPUT CFM POWER SUPPLY
V/PH/HZ/A FUEL SUPPLY CONNECTION DIMENSIONS L X W X H (IN)
WEIGHT (LBS)
IDF-400 395,000 320,000 2,500 115/1/60/151/2-4 PSI – Natural 10 PSI – Propane 42 Gallons – Oil
1″ NPT 70 x 24 x 52 450
IDF-400HS 390,000 3,500 115/1/60/15 1/4-4 PSI – Natural2-10 PSI – Propane 3/4” NPT 70 x 29 x 49 470
IDFO-400 395,000 2,500 115/1/60/15 42 Gallons - Oil 70 x 29 x 47 450
IDFO-400HS 390,000 4,000 115/1/60/15 42 Gallons - Oil 70 x 29 x 52 450
IDF-500 450,000 360,000 2,800 115/1/60/20 1/2-4 PSI – Natural 10 PSI – Propane 1″ NPT 70 x 35 x 52 467
IDFO-600 505,000 400,000 3,100 115/1/60/15 42 Gallons – Oil 70 x 35 x 50 467
IDF-750 700,000 631,000 5,000 208-230/3/60/20 1/2-4 PSI – Natural 10 PSI – Propane 1″ NPT 111 x 40 x 67 1,000
IDF-800 800,000 640,000 6,000208-230/1/60/30208-230/3/60/20460/3/60/10
1/2-4 PSI – Natural 10 PSI – Propane 1″ NPT 144 x 36 x 74 2,700
IDF-500
IDF-750 MIDFO-1100
MIDFO-1100 MIDFO-800IDF-800
HEATINGwww.temp-air.com | 800-836-7432 11HEATING www.temp-air.com | 800-836-7432 10
HYDRONIC HEATERSThis heater type provides dry, hot air in tightly enclosed or highly insulated areas that require no combustion byproducts.
HAH-250
FEATURES• Flameless operation• No combustion byproducts• Multiple heat exchangers can be placed to
heat separate areas
HAH-SERIESHAH-series heaters are ideal for providing dry, hot air in tightly enclosed or highly insulated construction areas. Hydronic heating systems use a boiler or heat exchanger to heat a glycol solution which is then pumped through flex hose connected to a portable heat exchanger or fan coil. A blower fan then moves air across the heated coil and into the space. Next, the heat exchangers heat, circulate, and reheat interior air within the structure resulting in minimal ventilation of the space. HAH-series heaters can also be used to thaw frozen ground or cure slabs and footings.
MODEL BTU/HR INPUT
BTU/HR OUTPUT
POWER SUPPLYV/PH/HZ/A
FUEL TYPEFUEL USAGE
DIMENSIONS L X W X H (IN)
WEIGHT (LBS)
MISCELLANEOUS PRODUCT SPECS
HAH-250 248,000 199,000
Central Heating Module 115/1/60/15
Heat Exchangers 115/1/60/10
Natural Gas 2.48 CCF Propane 2.71 GPH
54 x 35 x 81 820
Base - Skid
Air Delivery –(3) 1,000 CFM Hydronic Heat Exchangers
FEATURES• Two hose reel circuits• Self-contained towable unit• Environmentally friendly propylene glycol• Oilmate system allowing extended run
time between oil and filter changes• Some units contain a built-in generator
HTHW-SERIESMobile ground thawing units help bring winter construction sites to a work-ready state quickly, efficiently, and safely. HTHW-series units are perfect for thawing ground and preventing frost penetration in isolated, remote locations to prepare jobsites for dirt and concrete work throughout the winter season. The 50% propylene glycol mix (a low toxicity anti-freeze) is heated, run through a hose, and covered with curing blankets to thaw frozen ground. Hydro-Thaw mobile ground defrosting units can thaw up to 6,000 square feet of frozen ground and 12 inches deep per day.
MODEL BTU/HR INPUT
BTU/HR OUTPUT
POWER SUPPLYV/PH/HZ/A
FUEL TYPEFUEL USAGE
DIMENSIONS L X W X H (IN)
WEIGHT (LBS)
MISCELLANEOUS PRODUCT SPECS
HTHW-2000 280,000 231,000Central Heating Module 230/1/60/20Two – 115/1/60/15
Natural Gas 280 CCF Propane 3.0 GPH
Fuel Oil
205 x 100 x 98
7,400 No Fuel
8,400 Full Fuel
2 Heating CircuitsGas Supply Pressure –Two – 10 PSI On-Board Fuel Capacity –150 Gallons
HTHW-2000G 280,000 231,000Central Heating Module 230/1/60/20 Two – 120/1/60/15 8 kW Diesel Generator
Fuel Oil 195 x 102 x 90
7,860No Fuel
8,910 Full Fuel
2 Heating Circuits
On-Board Fuel Capacity –150 Gallons
HTHW-2015HG 360,000 360,000 Diesel Fuel 212 x 102 x 98
7,350No Fuel
8,960 Full Fuel
On-Board Fuel Capacity –230 Gallons
HTHW-2000G
HTHW-2000
HTHW-2000G HAH-250
HEATINGwww.temp-air.com | 800-836-7432 13HEATING www.temp-air.com | 800-836-7432 12
TAH-20
FEATURES• Centrifugal blowers• Remote thermostats• Fused disconnects for power connections• Fork pockets and lifting eyes for quick and
easy installation
STHP-SERIES & TAH-SERIESSTHP and TAH-series heaters can be used in structures where there is already a central steam boiler, hot water boiler, or chilled water plant onsite. These portable air handlers, when combined with steam or hot water, will provide dry, even heat or cooling to a space. This equipment works by circulating hot water, chilled water, or steam through a coil using a blower fan that moves air through the air handler. STHP and TAH-series models are ideal for use in new construction sites, building additions, military bases, municipal plants, power or utility companies, and processing applications.
STEAM / HOT WATER HEATERSThis type of heater is used at a facility in conjunction with an existing on-site central steam or hot water boiler.
MODEL CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) CONNECTIONS BASE PRESSURE
RANGE (LBS)MAXIMUM STEAM TEMP.
STHP-900 5,000230/1/60/17208-230/3/60/10460/3/60/5
78 x 35 x 72 1,241 2.5” NPT Casters 15 – 150 366˚ F
STHP-2000 11,000 230/3/60/30 460/3/60/15 140 x 46 x 50 2,100 2.5” NPT Skid 15 – 150 366˚ F
STHP-4000 22,000208/3/60/60 230/3/60/60 460/3/60/30
147 x 93 x 75 2,550 2.5” NPT Skid 15 – 150 366˚ F
MODEL CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) CONNECTIONS BASE PRESSURE
RANGE (LBS)MAXIMUM STEAM TEMP.
TAH-20 3,500230/1/60/15 230/3/60/10 460/3/60/5
63 x 34 x 76 1,375 2” NPT Casters 15 – 150 Water Only
TAH-50VFD 12,000 460/3/60/30 115 x 80 x 71 2,600 1” NPT Skid 10 – 150 Water Only
TAH-100 20,000208/3/60/80 230/3/60/70 460/3/60/35
120 x 100 x 83 5,165 4”-150 lb Flange Skid 10 – 150 Water Only
TAH-100VFD 20,000 460/3/60/35 120 x 100 x 83 5,165 4”-150 lb Flange Skid 10 – 150 Water Only
TAH-140VFD 27,000 460/3/60/60 120 x 100 x 83 6,000 4”-150 lb Flange Skid 10 – 150 Water Only
TAH-150 30,000208/3/60/100 230/3/60/90 460/3/60/45
166 x 100 x 102 7,900 4”-150 lb Flange Skid 10 – 150 Water Only
STHP-4000
STHP-4000
STHP-4000
T R U S T E D Q U A L I T Y S I N C E 1 9 6 5
P R O U D LY M A D E I N T H E U S A
COOLINGwww.temp-air.com | 800-836-7432 17COOLING www.temp-air.com | 800-836-7432 16
FEATURES• Available on wheels for portability• Quick and easy installation• 18-Gauge powder-coated steel finish• Copper-tube coils
PAC-SERIESTEMP-AIR 1-10 ton air-cooled portable air conditioners are designed to easily roll from room to room to provide convenient cooling to a space. These small PAC-series mobile air conditioners fit through a standard 36-inch wide door and operate at quiet sound levels. These air-cooled units also act as dehumidifiers with a condensate tank located in a sliding drawer on the bottom of the unit. Air is filtered using Merv 7 filters to remove air contaminants. These mobile air conditioners are ideal for anywhere general supplemental air conditioning is needed.
AIR-COOLED PORTABLE AIR CONDITIONERSOur air-cooled mobile air conditioners provide a simple spot cooling solution for spaces up to 7,800 square feet.
AIR-COOLED ACCESSORIESTEMP-AIR’s full line of accessories adapt air-cooled portable air conditioners to any installation application.
MODEL TONS CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE DISCHARGE
PAC-1.2 1.2 350 115/1/60/15 26 x 20 x 34 163 Casters Adjustable
PAC-1.5A 1.5 600 115/1/60/15 29 x 28 x 41 232 Casters Adjustable
PAC-1.5B 1.5 500 115/1/60/15 28 x 23 x 47 221 Casters Adjustable
PAC-2 2 750 208-230/1/60/20 29 x 28 x 41 251 Casters Adjustable
PAC-3 3 1,200 208-230/1/60/30 30 x 28 x 51 336 Casters Adjustable
PAC-5 6 2,300 208-230/1/60/60 42 x 30 x 70 650 Casters Adjustable
PAC-5P4 6 2,300 460/3/60/20 42 x 30 x 70 650 Casters Adjustable
PAC-5B23 6 2,300 208-230/3/60/40 47 x 31 x 64 740 Casters Adjustable
PAC-5B4 6 2,300 460/3/60/20 47 x 31 x 64 740 Casters Adjustable
PAC-10P 10 4,000 208-230/3/60/68 460/3/60/32 86 x 34 x 78 1,860 Casters Horizontal
MODEL DESCRIPTION
NK-2 6" nozzle kit for PAC-1.5B, PAC-2, and PAC-3
NK-3 8" nozzle kit for PAC-5, PAC-5B23, and PAC-5B4
CK-3 14” ceiling discharge kit for PAC-1.5B, PAC-2, and PAC-3
CK-4 20” ceiling discharge kit for PAC-5, PAC-5B23, and PAC-5B4
PC-1 Condensate pump for PAC-1.5B
PC-2 Condensate pump for PAC-2 and PAC-3
CP-2B 14" condenser return-air plenum for PAC-1.5B
CP-24B 14" condenser return-air plenum for PAC-2
CP-36B 14" condenser return-air plenum for PAC-3
CP-4B 20" condenser return-air plenum for PAC-5, PAC-5B23, and PAC-5B4
EP-2B 14" evaporator return-air plenum for PAC-1.5B
EP-24B 14" evaporator return-air plenum for PAC-2
EP-36B 14" evaporator return-air plenum for PAC-3
MODEL DESCRIPTION
EP-4B 20" evaporator return-air plenum for PAC-5, PAC-5B23, PAC-5B4, PAC-10P23, and PAC-10P4
DA-10 Cold-air supply duct adapter for PAC-1.5B, PAC-2, and PAC-3
DA-14 Cold-air supply duct adapter for PAC-5, PAC-5B23, and PAC-5B4
CD-60 14-60P plug kit with 6' cord for PAC-5
CF-18B Condenser air filter (12 per case) for PAC-1.5B
CF-24B Condenser air filter (12 per case) for PAC-2
CF-36B Condenser air filter (12 per case) for PAC-3
CF-60B Condenser air filter (12 per case) for PAC-5, PAC-5B23, and PAC-5B4
EF-18B Evaporator air filter (12 per case) for PAC-1.5B
EF-24B Evaporator air filter (12 per case) for PAC-2
EF-36B Evaporator air filter (12 per case) for PAC-3
EF-60B Evaporator air filter (12 per case) for PAC-5, PAC-5B23, and PAC-5B4
PAC-1.5B PAC-10PPAC-5B4
COOLINGwww.temp-air.com | 800-836-7432 19COOLING www.temp-air.com | 800-836-7432 18
FEATURES• Quiet, high-efficiency compressors• Electronic temperature control• Washable, aluminum-mesh coil air filters
PACW-SERIESWater-cooled portable air conditioners provide cooling of enclosed spaces where you are unable to discharge the condenser heat. PACW-series units do not require condenser air ducting thus preventing negative air pressure. Alternatively, the rejected heat is transferred through the water and leaves the condenser coil through a drain. This series has very efficient water-flow management and can be used in higher temperature areas than air-cooled units. PACW-series air conditioners are most cost-effective to operate when there is access to a central chiller plant.
WATER-COOLED PORTABLE AIR CONDITIONERSOur water-cooled mobile air conditioners can provide simple spot cooling or intricate long-term cooling solutions.
MODEL TONS CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE DISCHARGE
PACW-1 1 400 115/1/60/15 20 x 13 x 32 110 Casters Adjustable
PACW-1.5 1.5 600 115/1/60/15 24 x 13 x 38 150 Casters Adjustable
PACW-2 2 810 208-230/1/60/15 24 x 13 x 38 160 Casters Adjustable
PACW-3 3 1,300 208-230/1/60/20 28 x 16 x 47 240 Casters Adjustable
PACW-4.5K2 4.5 1,900 208-230/3/60/30 70 x 35 x 41 450 Casters Horizontal
PACW-5 5 1,950 460/3/60/20 39 x 28 x 52 520 Casters Adjustable
PACW-5.5K21 5.5 2,200 208-230/1/60/45 70 x 35 x 41 751 Casters Horizontal
PAC-15T2
FEATURES• Convenient single unit design• Equipped with remote thermostats for
precise temperature control
PAC-SERIESLarge PAC-series industrial, portable air conditioners are used to precisely control temperature and humidity levels in a space. These air conditioners are typically placed outside of a structure and can provide up to 75 tons of cooling. These commercial mobile air conditioners are ideal for new construction, retrofits, supplemental cooling, emergency cooling, industrial process cooling, disaster relief, and special event cooling. Our 5 to 75-ton air conditioner rentals can provide simple spot cooling or intricate long-term cooling solutions.
COOL ONLY INDUSTRIAL AIR CONDITIONERS Our industrial air conditioners efficiently cool areas that require a large amount of cooling.
MODEL TONS CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE ESP*
(IN)
PAC-5T21 5 2,000 208-230/1/60/50 86 x 47 x 44 906 Casters 1.14
PAC-10T2 10 4,000 208-230/3/60/60 94 x 64 x 55 1,426 Casters 2
PAC-15T2 15 6,000 208-230/3/60/90 110 x 74 x 68 2,176 Casters 2
PAC-20T2 20 8,000 208-230/3/60/125 140 x 94 x 66 3,102 Skid 2
PAC-20T4 20 8,000 460/3/60/70 124 x 92 x 66 2,987 Skid 2
PAC-25T4 25 10,000 460/3/60/70 124 x 92 x 79 3,393 Skid 1.5
PAC-30R4 30 9,000 460/3/60/80 120 x 96 x 102 7,200 Skid 2.75
PAC-60R4 60 18,000 460/3/60/180 240 x 98 x 102 14,300 Skid 6
PAC-75T4 75 14,000 – 26,000 460/3/60/200 276 x 126 x 100 13,800 Skid 3.5
*ESP = External Static Pressure in Inches Water Column
PACW-2
PACW-4.5K2
PACW-3 PAC-75T4
PAC-10T2
COOLINGwww.temp-air.com | 800-836-7432 21COOLING www.temp-air.com | 800-836-7432 20
PAC-50T4H
FEATURES• Convenient single unit design• Equipped with remote thermostats for
precise temperature control• Includes electric heat mode option• Includes dehumidifying mode option on
many units
PAC-SERIESLarge PAC-series industrial, portable air conditioners are used to precisely control temperature and humidity levels in a space. These air conditioners are typically placed outside of a structure and can provide up to 75 tons of cooling. In addition to its cooling capabilities, many PAC-series units include electric heating and dehumidifying mode options. These commercial mobile air conditioners are ideal for new construction, retrofits, supplemental cooling, emergency cooling, industrial process cooling, disaster relief, and special event cooling.
COOL / HEAT / DEHUMIDIFY INDUSTRIAL AIR CONDITIONERS Our industrial air conditioners efficiently cool areas that require a large amount of cooling.
MODEL TONS CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE ESP*
(IN)
PAC-10T2HD 10 4,000 208-230/3/60/100 94 x 57 x 65 1,200 Casters 2
PAC-10T4HD 10 4,000 460/3/60/80 98 x 60 x 64 1,400 Casters 2
PAC-15T2HD 15 6,000 208-230/3/60/260 117 x 80 x 71 1,950 Casters 2
PAC-15T4HD 15 6,000 460/3/60/130 117 x 80 x 71 1,950 Casters 2
PAC-25T4HD 25 10,000 460/3/60/150 147 x 94 x 68 3,400 Skid 1.5
PAC-50T4HD 50 18,000 460/3/60/160 243 x 100 x 93 8,400 Skid 2.5
*ESP = External Static Pressure in Inches Water Column
MODEL TONS CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE ESP*
(IN)
PAC-3T4H 3 1,200 460/3/60/30 68 x 36 x 51 739 Casters 1.14
PAC-5T4H 5 2,000 460/3/60/30 96 x 53 x 52 1,320 Casters 1.14
PAC-15T2H 15 6,000 208-230/3/60/130 116 x 80 x 71 2,300 Casters 2
PAC-15T4H 15 6,000 460/3/60/100 110 x 74 x 68 2,193 Casters 2
PAC-20T4H 20 8,000 460/3/60/130 140 x 94 x 66 2,950 Skid 2
PAC-25T2H 25 10,000 208-230/3/60/200 140 x 88 x 65 3,525 Skid 1.5
PAC-25T4H 25 10,000 460/3/60/130 140 x 88 x 65 3,108 Skid 1.5
PAC-50T4H 50 18,000 460/3/60/180 243 x 100 x 93 8,400 Skid 2.5
*ESP = External Static Pressure in Inches Water Column
PAC-50T4H
PAC-15T2H
PAC-25T4HD
PAC-25T4HD PAC-25T4HD PAC-50T4HD
AIR MANAGEMENTwww.temp-air.com | 800-836-7432 23COOLING www.temp-air.com | 800-836-7432 22
AIR HANDLERSThis combination cooling and heating unit is used at a facility in conjunction with an existing on-site central steam boiler, central hot water boiler, temporary chiller, or temporary boiler.
FEATURES• Centrifugal blowers • Remote thermostat control• Fused disconnects for power connections• Fork pockets and lifting eyes for quick
and easy installation
TAH-SERIESTAH-series units can be used in structures where there is already a central steam boiler, hot water boiler, or chilled water plant onsite. These portable air handlers, when combined with steam or hot water, will provide dry, even heat or cooling to a space. This equipment works by circulating hot water, chilled water, or steam through a coil using a blower fan that moves air through the air handler. TAH-series models are ideal for use in new construction sites, building additions, military bases, municipal plants, power or utility companies, and processing applications.
TAH-100
TEMP-AIR offers 10 to 1,200 ton short term air-cooled and water-cooled chillers.
TCA-SERIESIf a permanent chiller system experiences sudden failure or will be undergoing planned maintenance, a chiller rental provides an effective temporary cooling solution. Alternatively, rental chillers may be a more cost effective solution for short term seasonal chiller needs versus investing in a permanent chiller system. Portable chiller rentals may be used at manufacturing plants, industrial processing facilities, hospitals, and schools. Temporary chillers can also be coupled with temporary air handlers for comfort cooling in spaces such as warehouses and large tent events.
TCA-500
FEATURES• Integrated pump • Heavy duty frame with lift points• Camlock type electrical connections• Flanged or Victaulic connections• Throttling valves
CHILLERS
MODEL TONS TYPE POWER SUPPLYV/PH/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) GPM PUMP
(HP)FLANGED PUMP (IN) PSIG
TCA-10 10 Air-Cooled 460/3/31 84 x 35 x 66 1,500 24-48 1.5 1.5 40
TCA-10P 10 Air-Cooled 460/3/31 84 x 35 x 66 1,500 24-48 1.5 1.5 40
TCA-25 25 Air-Cooled 460/3/65 138 x 63 x 93 3,300 30-89 5 2.5 145
TCA-35 35 Air-Cooled 230/3/200 175 x 63 x 93 4,081 30-90 5 2.5
TCA-40 40 Air-Cooled 460/3/95 122 x 100 x 96 3,680 48-144 5 2.5
TCA-60 60 Air-Cooled 460/3/135 181 x 100 x 97 7,740 150 10 4
TCA-100 100 Air-Cooled 460/3/215 219 x 100 x 98 9,700 100-300 10 4
TCA-110 110 Air-Cooled 460/3/250 274 x 100 x 102 10,700 132-396 10 4
TCA-140 140 Air-Cooled 460/3/314 264 x 100 x 102 14,400 400 20 4
TCA-155 155 Air-Cooled 460/3/346 264 x 100 x 102 14,300 400 20 4
TCA-200 200 Air-Cooled 460/3/455 274 x 100 x 102 15,672 285-725 30 6
MODEL CFM POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) CONNECTIONS BASE MAX
PRESSUREMAX GPM
ESP*(IN)
TAH-20 3,500230/1/60/15 208-230/3/60/10 460/3/60/5
63 x 34 x 76 1,372 2.0″ NPT Casters 100 55 0.63
TAH-50VFD 12,000 460/3/60/30 115 x 80 x 71 2,600 1" NPT Skid 100 200 5
TAH-100 20,000208/3/60/80 230/3/60/70 460/3/60/35
120 x 100 x 83 5,165 4″-150 lb Flange Skid 100 275 3.5
TAH-100VFD 20,000 460/3/60/35 120 x 100 x 83 5,165 4″-150 lb Flange Skid 100 275 3.5
TAH-140 27,000 460/3/60/60 120 x 100 x 83 5,500 4″-150 lb Flange Skid 100 375 3.5
TAH-140VFD 27,000 460/3/60/60 120 x 100 x 83 6,000 4″-150 lb Flange Skid 100 375 3.5
TAH-150 30,000208/3/60/110 230/3/60/100 460/3/60/50
166 x 100 x 102 7,900 4″-150 lb Flange Skid 100 375 3.5
*ESP = External Static Pressure in Inches Water Column
TAH-50VFD
TAH-20
TCA-100
TCA-10P
AIR MANAGEMENTwww.temp-air.com | 800-836-7432 25AIR MANAGEMENT www.temp-air.com | 800-836-7432 24
FEATURES• Remote thermostat control• Electric heat and cool mode options• Remove up to 556 gallons of water
per day
PAC-SERIESPAC-series industrial, portable dehumidifiers are used to precisely control humidity and temperature levels in a space. These mobile refrigerant units are ideal for areas with high temperatures and moisture levels above 45-percent relative humidity. In addition to its dehumidifying capabilities, these PAC-series units include electric heating and cooling mode options. These commercial mobile dehumidifiers are ideal for new construction, retrofits, supplemental, emergency, industrial process, disaster relief, and special event dehumidifying applications.
PAC-15T2HD
DEHUMIDIFIERSTEMP-AIR offers both desiccant and refrigerant dehumidifiers for ultimate moisture and temperature control.
FEATURES• Remote thermostats• Gas and electric options• Remove up to 771 gallons of
water per day
TD-SERIESTD-series mobile dehumidifiers remove unwanted moisture and precisely control both humidity and temperature levels in a space. Desiccant dehumidifiers are used for applications with moisture levels below 45-percent relative humidity. TD-series equipment can remove 23 to 771 gallons of water per day. These packaged desiccant dehumidifiers can be used to help speed up construction finishing in flooring, painting, and millwork conditioning applications. TD-series units can also be used to restore flood damaged buildings quickly preventing mold, mildew, and other allergens.
TD-2000G
MODEL CFM TYPE GALLONS PER DAY
POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE ESP*
(IN)
TD-200 538 Refrigerant (DX) 28 115/1/60/15 24 x 22 x 44 162 Casters
TD-600E 600 Desiccant 23 230/1/60/30 32 x 26 x 43 140 Casters 0.75
TD-1000E 1,000 Desiccant 43 230/1/60/90 68 x 34 x 50 600 Casters 2
TD-2000E 2,000 Desiccant 143 460/3/60/60 78 x 34 x 60 895 Casters 2
TD-2000G 2,000 Desiccant 143 230/1/60/30 78 x 34 x 60 900 Casters 2
TD-5000E 5,000 Desiccant 358 460/3/60/175 172 x 52 x 84 5,150 Skid 5
TD-5000G 5,000 Desiccant 358 460/3/60/30 172 x 52 x 84 5,150 Skid 5
TD-7500G 7,500 Desiccant 555 230/3/60/40 460/3/60/20 144 x 74 x 74 4,100 Skid 2
TD-15000G 15,000 Desiccant 771 460/3/60/60 204 x 96 x 101 10,000 Skid 3
*ESP = External Static Pressure in Inches Water Column
MODEL CFM TYPE GALLONS PER DAY
POWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN)
WEIGHT (LBS) BASE ESP*
(IN)
PAC-10T2HD 4,000 Refrigerant (DX) 237 230/3/60/100 94 x 57 x 65 1,200 Casters 2
PAC-10T4HD 4,000 Refrigerant (DX) 237 460/3/60/80 98 x 60 x 64 1,403 Casters 2
PAC-15T2HD 6,000 Refrigerant (DX) 344 230/3/60/260 117 x 80 x 71 1,950 Casters 2
PAC-15T4HD 6,000 Refrigerant (DX) 344 460/3/60/130 117 x 80 x 71 1,950 Casters 2
PAC-25T4HD 10,000 Refrigerant (DX) 556 460/3/60/150 147 x 94 x 68 3,393 Skid 1.5
PAC-50T4HD 18,000 Refrigerant (DX) 354 460/3/60/160 243 x 100 x 93 8,400 Skid 2.5
*ESP = External Static Pressure in Inches Water Column
TD-5000E
TD-600E
PAC-10T2HD
PAC-25T4HD
AIR MANAGEMENTwww.temp-air.com | 800-836-7432 27AIR MANAGEMENT www.temp-air.com | 800-836-7432 26
FANSOur industrial fans are used to distribute air throughout various areas within a space.
FAN 24
FEATURES• Both cart and wheel options available• Quiet, maintenance-free operation• Built to withstand harsh environments
FAN-SERIESPortable and versatile, these industrial fans can be used to distribute air in heating, cooling, and dehumidifying applications. Built for durability, our electric fans are suitable for high-temperature, dusty, or damp environments. TEMP-AIR offers a variety of fan sizes to fit your application ranging from 4,500 to 27,000 CFM. Their high volume air movement and exchange make these fans ideal for structural and space drying applications. Light, medium, and heavy duty fan types are available. Fan motors are ball-bearing smooth for quiet, virtually maintenance-free operation.
FEATURES• Plug into standard 115V outlets• Equipped with casters for portability• Easily adapted for permanent installation
C-SERIESThe C-2000 portable air filtration unit was developed to handle the rigorous demands of micro-decontamination operations where reliable, high volume air filtration is essential to safety and productivity. This compact air scrubber allows for the purification of air contaminants most commonly in hospital, biotechnology, scientific laboratory, pharmaceutical manufacturing, new construction, and renovation settings. The C-2000 mobile air cleaner can be used in negative pressure applications as well as in recirculation and positive pressure applications.
AIR FILTRATIONPortable air scrubbers remove air contaminants from areas where safety and productivity would otherwise be compromised.
C-2000
MODEL HEPA EFFICIENCY CFM SPEED
CONTROLPOWER SUPPLYV/PH/HZ/A
DIMENSIONS L X W X H (IN) HOUSING PREFILTER
SIZE (IN) HEPA SIZE WEIGHT (LBS)
C-2000 99.7% @ 0.3 Micron
2,000 / 1,600 2-Speed 115/1/60/15 37 x 28 x 33 Stainless
Steel 25 x 25 24 x 24 x 11.5 170
C-2000
MODEL DESCRIPTION CFM POWER SUPPLYV/PH/HZ/A MOTOR HP DIMENSIONS
L X W X H (IN)WEIGHT (LBS) BASE
FAN PROP 24" Light Duty, Wire Cage 4,500 115/1/60/10 0.25 24 x 16 x 26 45 3' or 5'
Pedestal
FAN 20 MLT 20" Medium Duty, Molded Plastic 5,480 115/1/60/10 0.5 12 x 25 x 25 44 Floor Stand
FAN 24 24" Medium Duty, Molded Plastic 5,790 115/1/60/10 0.5 28 x 22 x 28 48 2-Wheel Cart
FAN 30 BLY 30" Heavy Duty, on Cart 13,700 115/1/60/20
230/1/60/15 1.5 32 x 37 x 49 154 2-Wheel CartBar Joist
FAN 36 36" Medium Duty, Molded Plastic 11,000 115/1/60/10 0.5 20 x 38 x 38 68 2-Wheel Cart
FAN 36 GV 36" Heavy Duty, Metal 18,000
208-230/1/60/20208-230/3/60/10460/3/60/5
3 48 x 32 x 55 375 4-Wheels
FAN 48S 48" Medium Duty, Metal 25,000
208-230/1/60/20208-230/3/60/10460/3/60/5
2 55 x 24 x 61 457 4-Wheels
FAN 48 48" Heavy Duty, Aluminum 27,000
230/1/60/20230/3/60/10460/3/60/5
3 62 x 28 x 66 320 4-Wheels
*ESP = External Static Pressure in Inches Water Column
LEFT: FAN 48, RIGHT: FAN 36
ARKANSAS CHILDREN’S HOSPITALSPRINGDALE, ARKANSAS NEW CONSTRUCTIONPAC-SERIES
URBAN TILLCHICAGO, ILLINOIS HYDROPONICSPAC-SERIES
GERALD R. FORD AIRPORTGRAND RAPIDS, MICHIGANRENOVATION THP AND CH-SERIES
PROJECTS
NIKE HEADQUARTERSBEAVERTON, OREGONNEW CONSTRUCTIONTHP, ETHP, TD AND TCA-SERIES
SUPERBOWL LIHOUSTON, TEXASSPECIAL EVENTPAC, ETHP AND THP-SERIES
WASTEWATER TREATMENT FACILITYSEATTLE, WASHINGTON FLOOD RELIEF THP-SERIES
28
3700 West Preserve BoulevardBurnsville, Minnesota 55337 800.836.7432 temp-air.com
Atlanta3715 - 1st Avenue, Bldg 4AColumbus, GA 31904800.656.6000
Columbus8275 Estates ParkwayPlain City, OH 43064800.444.3481
Kansas City200 NW Harlem RoadKansas City, MO 64116800.430.0523
Portland440A Industrial WayLongview, WA 98632800.859.1085
Boston270 Southwest CutoffWorcester, MA 01604800.666.8133
Denver3697 South Natches CourtEnglewood, CO 80110800.577.7053
MilwaukeeN901 County Road LWatertown, WI 53098800.558.9209
Sacramento3299 Luyung DriveRancho-Cordova, CA 95742800.859.1085
Chicago39W171 Highland AvenueElgin, IL 60124800.283.2843
Detroit31253 Utica RoadFraser, MI 48026800.678.1488
Minneapolis3700 W. Preserve BoulevardBurnsville, MN 55337800.836.7432
Salt Lake City1471 W. 1250 S., Ste. 110Orem, UT 84057800.577.7053
ClevelandPO Box 1118Medina, OH 44258800.443.3301
Gulfport14301 Creosote Road, Unit BGulfport, MS 39503800.283.6743
Philadelphia200 Happy LaneNewark, DE 19711800.656.6000
St. Louis29 International Plaza CourtSt. Ann, MO 63074800.283.6743