Teledyne Analytical Instruments TELEDYNE AAQMS Systems

description

Teledyne Analytical Instruments. TELEDYNE AAQMS Systems. Analytical Instruments for AQMS. CO – GFC7001E NO2 – 9110E SO2 – 6400E VOC – 4060 Ozone – 400E Particulate Matter (2.5 & 10) – Beta Ray Attenuation Zero Air Generator – 701 Mass Flow Calibrator – 702E - PowerPoint PPT Presentation

Transcript of Teledyne Analytical Instruments

Page 1: Teledyne Analytical Instruments

Teledyne Analytical Instruments

TELEDYNE AAQMS Systems

Page 2: Teledyne Analytical Instruments

2

Analytical Instruments for AQMS CO – GFC7001E

NO2 – 9110E

SO2 – 6400E

VOC – 4060

Ozone – 400E

Particulate Matter (2.5 & 10) – Beta Ray Attenuation Zero Air Generator – 701

Mass Flow Calibrator – 702E

WMS – Weather Monitoring Sensors

DAS – Win collect

Page 3: Teledyne Analytical Instruments

3

PM 2.5 / PM10

Page 4: Teledyne Analytical Instruments

4

PM 2.5 / PM10 The Model 602 Beta PLUS Particle Measurement System is an advanced-design,

automatic, dual-channel, ambient particulate matter (PM) analyzer/sampler utilizing a measurement principle based on attenuation of beta radiation by PM collected on pairs of matched sample filters. The two channels have separate and independent sample inlets, filter holders, and flow control, but share a single beta attenuation mass measurement system. Each channel can be separately configured to measure various particle size ranges by use of the appropriate inlet and particle size separator, and a wide range of sample flow rates and collection periods can be programmed.

Beta Ray Attenuation

At the beginning of the sampling period, beta ray transmission is measured 1 across a clean section of the filter. After the particulate matter is drawn into the sample inlet and deposited on the filter, the beta ray transmission is re-measured. The difference between the two measurements is used to determine, with exceptional accuracy, the particulate concentration.

1- attenuation technique. This technique has been implemented on the basis of a theoretical analysis of the interaction between beta rays and matter that led to the formulation of a generalized parametric equation. This equation describes the relationship between the attenuation of the beta-particle flux passing through the thin film and the mass thickness of this matter film.

Page 5: Teledyne Analytical Instruments

5

PM 2.5 / PM10

Page 6: Teledyne Analytical Instruments

6

PM 2.5 / PM10

Page 7: Teledyne Analytical Instruments

7

PM 2.5 / PM10 Features US EPA Federal Equivalent Method (FEM) Certifications for PM10, PM2.5 and PM10-

2.5

Two independent sampling lines with a single beta attenuation-based mass sensor

Collect samples onto 47mm Ø filters for preservation and subsequent chemical analysis

>95% active sampling per measurement cycle

Accurate hourly results using direct beta attenuation mass measurement

Automatic flow and mass sensor verifications

Uses spy filter to counteract humidity interference

Digital and analog communications

Remote monitoring, data retrieval, and control

Two-year warranty

Page 8: Teledyne Analytical Instruments

8

PM 2.5 / PM10Ionizing Radiation HazardsThe Model 602 BetaPLUS Particle Measurement System contains a 14C beta source, with 3.7 MBq (100 μCi) nominal activity. The source is contained in an inaccessible mechanical block integrated within the instrument. Only radiation dose-rates can be detected outside of the instrument. Consequently, under normal operating conditions there is no contamination risk. In the event of a serious accident, such as a fire, there is a risk that radioactive material may be dispersed into the environment. However, an analytic evaluation of various improbable and worst-case scenarios concluded thatestimated dose values for individuals and the general population are within safe limits.(270μCi, CA shipping laws)

CAUTION: The source is not user serviceable and can only be accessed through use of a specialized tool exclusively available to Teledyne API personnel trained in its use.CAUTION: Use this Instrument Only as Intended and Prescribed. The instrument must be used only for the operations and in the environmental conditions explicitly described in this manual. Any other use is considered improper and prohibited.

Page 9: Teledyne Analytical Instruments

9

Analytical Instruments for AQMS CO – GFC7001E

NO2 – 9110E

SO2 – 6400E

VOC – 4060

Ozone – 400E Particulate Matter (2.5 & 10) – Beta Ray Attenuation

Zero Air Generator – 701 Mass Flow Calibrator – 702E

WMS – Weather Monitoring Sensors

DAS – Win collect

Page 10: Teledyne Analytical Instruments

10

Zero Air Generator – 701

Page 11: Teledyne Analytical Instruments

11

ZAG - Model 701 The Model 701 is an excellent source of clean, dry air for dilution calibrators. It also

may be used as a source of purge air for permeation tube ovens or burner air for FID analyzers. The basic Model 701 includes an oil-less, diaphragm-less pump plus scrubbers to remove SO2, NO, NO2, O3 and H2S. Optional scrubbers are available to remove CO and Hydrocarbons. Inlet air is pulled into the pump and route through a pre-cooler and water trap that removes water. The air then passes through the regenerative scrubber, where the final drying occurs, and then to the storage tank.

Tank pressure is monitored and maintained at a preset level by cycling the pump automatically as needed, extending pump and scrubber life. The outlet air from the tank is cleaned and goes through a filter to produce a clean and dry zero air supply. A microcontroller cycles the regenerative dryer and the water trap valves, ensuring that the pump does not start against full head pressure. The Model 701 is an ideal accessory to the Model 700E Mass Flow Calibrator.

Output: 10 SLPM @ 30 psig , 20 SLPM @ 30 psig (optional)

Dew point: -20°C up to 15 LPM; -10°C above 15 LPM

Dryer: Regenerative heatless dryer with lifetime of greater than 5 years

Page 12: Teledyne Analytical Instruments

12

Zero Air Generator - Model 701

Page 13: Teledyne Analytical Instruments

13

Zero Air Generator - Model 701 The M701 dries and scrubs ambient air to produce zero air.

The compressor draws air in from the rear panel inlet filter. At the compressor outlet, the air is under pressure and hot from the compression. The relative humidity is high as a result of the high pressure. The air is conducted through the cooling coil , the pressure still high but the temperature is reduced to ambient, the wet air passes through a coalescing filter where the excess water is separated and settles in the bottom of the filter. The partially dried air passes a pressure relief valve,(set to open at 90 psig.)and enters the Regenerative Dryer which removes essentially all the remaining water and a portion of the other contaminants.

Page 14: Teledyne Analytical Instruments

14

Zero Air Generator - Model 701

The Hydrocarbon scrubber where Hydrocarbons and CO are catalytically converted to CO2 and water. Then, the NO scrubber where NO is oxidized to NO2, then, the activated charcoal scrubber where the NO2 is absorbed. Then the optional CO scrubber, where CO is catalytically oxidized to CO2, Finally, the clean dry air passes through a fine particulate filter and leaves the M701 through the rear panel bulkhead union (Zero Air Out).

Page 15: Teledyne Analytical Instruments

15

Zero Air Generator - Model 701

Page 16: Teledyne Analytical Instruments

16

ZAG - Model 701Output STD 20 SLPM @ 30 psig Max delivery pressure 35 psigDewpoint < 15 SLPM < -20 C > 15 SLPM < -10 C SO2 <0.5 ppb NO <0.5 ppb NO2 <0.5 ppb O2 <0.5 ppbHC/CO Options < 0.02 ppm HC / < 0.025 ppm CODimensions 8.75” H x 17”W x 23.5”D (22.2 cm x 43.2 cm x 60 cm)Weight 55 lbs. (25 Kg)Operating Temp 5-40CPower 115V, 60Hz, 3.5A 230V, 50Hz, 2.0A 220V, 60 Hz, 2.2A

Page 17: Teledyne Analytical Instruments

17

ZAG - Model 701

Page 18: Teledyne Analytical Instruments

18

Analytical Instruments for AQMS CO – GFC7001E

NO2 – 9110E

SO2 – 6400E

VOC – 4060

Ozone – 400E Particulate Matter (2.5 & 10) – Beta Ray Attenuation

Zero Air Generator – 701

Mass Flow Calibrator – 702E WMS – Weather Monitoring Sensors

DAS – Win collect

Page 19: Teledyne Analytical Instruments

19

MFC – Model 700E The Model 700E is a microprocessor based calibrator for precision gas analyzers. Using

a combination of highly accurate mass flow controllers and compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks. Up to 4 gas sources may be used. As many as 50 independent calibration sequences may be programmed into the M700E, covering time periods of up to one year. The setup of sequences is simple and intuitive. These sequences may be actuated manually, automatically, or by a remote signal. The sequences may be uploaded remotely, including remote editing! All programs are maintained in non-volatile memory.

The M700E design emphasizes fast response, repeatability, overall accuracy and ease of operation. It may be combined with the Model 701 Zero Air Generator to provide the ultimate in easy to use, precise calibration for your gas analyzers.

Dilution System:-

1. Flow Measurement Accuracy: ± 1% full scale

2. Flow Range of Dilution Air: 0 to 10 SLPM (Standard Liter per Minute)

3. Zero Air requirements: 10 SLPM @ 30 psi

4. Calibration Gas Input Ports: 4 (configurable)

5. Diluents Gas Input Ports: 1 & Response Time: 60 seconds

Page 20: Teledyne Analytical Instruments

20

MFC – Model 700E

Page 21: Teledyne Analytical Instruments

21

MFC – Model 700E

Page 22: Teledyne Analytical Instruments

22

MFC – Model 700E

OPTIONAL HARDWARE AND SOFTWAREINTERNAL OZONE GENERATOR (OPT 01A)

Because ozone (O3) quickly breaks down into molecular oxygen (O2), this calibration gas cannot be supplied in precisely calibrated bottles like other gases such as SO2, CO, CO2 NO, H2S, etc. The optional O3 generator extends the capabilities of the M700E Dynamic Dilution Calibrator dynamically generate calibration gas mixtures containing O3.

UV PHOTOMETER MODULE (OPT 02A)

The photometer option increases the accuracy of the M700E calibrator’s optional O3 generator by directly measuring O3 content of the gas output by the generator. The photometer’s operation is based on the principle that ozone molecules absorb UV light of a certain wavelength (Beer-Lambert law)

Page 23: Teledyne Analytical Instruments

23

MFC – Model 700E

Page 24: Teledyne Analytical Instruments

24

MFC – Model 700E

RS232 MODEM CABLES (OPT 60A & OPT 60B) RS-232 MULTI-DROP (OPT 62) ETHERNET CABLE (OPT 60C) ETHERNET (OPT 63A) ETHERNET + MULTI-DROP (OPT 63C) PERMEATION TUBE OVEN OPTION (OPT 05) The permeation tube gas generator is an alternative method for producing known

concentrations of stable gas such as SO2, NO2, etc. The generator consists of a temperature regulated permeation tube oven, a flow restrictor, an optional output desorber, and a user-supplied permeation tube. The optional desorber can improve the response time of the calibrator especially when operating with NO2 tubes.

Page 25: Teledyne Analytical Instruments

25

MFC – Model 700E

Page 26: Teledyne Analytical Instruments

26

Analytical Instruments for AQMS CO – GFC7001E

NO2 – 9110E

SO2 – 6400E

VOC – 4060

Ozone – 400E Particulate Matter (2.5 & 10) – Beta Ray Attenuation

Zero Air Generator – 701

Mass Flow Calibrator – 702E

WMS – Weather Monitoring Sensors DAS – Win collect

Page 27: Teledyne Analytical Instruments

27

WMS – Weather Monitoring Sensors

Model 083D – RH Moisture sensor

The Model 083D sensor probe represents sensitivity, accuracy, linearity and stability not encountered with conventional relative humidity sensors. It is extremely well suited for meteorological, industrial, laboratory and other demanding applications. The Model 083D RH sensor can also be supplied with a temperature sensor mounted in it and used with various radiation shields for reliable, accurate measurements

Operation:The Model 083D Relative Humidity Sensor is based upon the capacitance change of a polymer thin film capacitor. A one-micron thick dielectric polymer layer absorbs water molecules through a thin metal electrode and causes capacitance change proportional to relative humidity. The thin polymer layer reacts very fast, and therefore, the response time is very short–less than five seconds to 90% of the final value of relative humidity. Sensing Element: Thin film capacitorRange: 0 - 100% relative humidityTemperature Range: -20°C to +60°CResponse Time: Less than 15 seconds at 20°C of final (with filter)Accuracy: 0 - 10% ±3% , 10 - 90% ±2%, 90 - 100% ±3%

Page 28: Teledyne Analytical Instruments

28

WMS – Weather Monitoring SensorsSolar Radiation Sensors

Model 095 Pyranometer:The Pyranometer incorporates a multi-junction differential thermopile and a precision ground optical glass hemisphere which is transparent to wavelengths 0.285 to 2.80 microns. It is used for high precision, broad bandwidth measurements of incident solar radiation.Specifications:Spectral Response: Nanometers: 285 - 2800 Microns:0.28 - 2.8Calibration: Integrating hemisphere approx. 1 cal cm-2 min-1, at 25°CSensitivity:** 11 mV/kwatt meter-2, approx.Impedance: 350 ohms, approx.Temperature Depend.: ±1.5% constancy from -20°C to +40°CLinearity: ±1% from 0 to 1400 watts meter-2Response Time: 5 second (1/e signal)Cosine Response: ±2% from normalization 0°-70° zenith angle; ±5% 70°-80° zenith angleDimensions: 5.75 in (14.6 cm) diam. x 21 in (53.4 cm) h, including mountWeight: 4 lbs (1.8 kg), including mountMounting: Leveling plate and mounting base include

Page 29: Teledyne Analytical Instruments

29

WMS – Weather Monitoring SensorsTechnical Terms

•Pyranometer:A pyranometer is used to measure broadband solar irradiance on a planar surface and it is a sensor that measures the solar radiation flux density (in watts per metre square) from a field of view of 180 degrees.• Thermopile (Thermistor)A thermopile is an electronic device that converts thermal energy into electrical energy.

Page 30: Teledyne Analytical Instruments

30

WMS – Weather Monitoring Sensors

The accurate measurement of rain and snow precipitation remains one of the most basic elements of meteorology.

Operation:-

A dual-chambered tipping bucket assembly is located below the collection funnel. When a precise amount of precipitation has been collected in one side of the bucket, gravity tips the assembly and activates a reed switch. A momentary electrical contact closure through the switch is provided for each increment of rainfall. The sample is discharged through the base of the gauge.

Construction:-

The heavy machined aluminum base provides a stable platform for the tipping assembly. The bucket is made from stainless steel and is Teflon coated to prevent retention of the sample. The bucket pivots are precision machined and fitted with jeweled bearings to reduce wear and friction. The funnel is powder coated aluminum and has two screens for preventing leaves and other debris from entering or clogging the gauge. A circular bubble-level and adjustable feet facilitate proper mounting of the unit. Major components are finished in catalyzed polyurethane paint to withstand the environment.

Model 370 Funnel Dia : 8 in (20.3 cm) , Standard Calibration: 0.01 in

Precipitation Gauges

Page 31: Teledyne Analytical Instruments

31

WMS – Weather Monitoring SensorsWind Direction Sensor

The Model 024A Wind Direction Sensor is an accurate, durable and economical sensor suitable for a wide range of wind study applications. It is designed for long term unattended operation in most meteorological environments.OperationThe sensor incorporates a precision wire-wound potentiometer for accurate resolution of wind direction. The potentiometer is directly coupled to the vane assembly. Variations in wind direction produce a corresponding varying voltage, which lends itself to both digital and analog measurement systems.

Page 32: Teledyne Analytical Instruments

32

WMS – Weather Monitoring SensorsWind Direction Sensor

Specification:Range: 0 - 360°Starting Threshold: 1.0 mphAccuracy: ±5°Delay Distance: Less than 5 ft Damping Ratio(A parameter used to describe the response of a wind vane to a sudden change in wind direction. It is defined as the ratio of the actual damping to the critical damping)Standard: 0.25(Metal Vane), Fast Response: 0.4 (Foam Vane)Potentiometer: Sand, Dust, Fungus: MIL-E-5272 , Salt Spray: MIL-E-12934Electrical Range: 0 - 360° , 0 - 540°Operating Range: -50°C to +70°CWeight: 1 lb 2 oz

Page 33: Teledyne Analytical Instruments

33

WMS – Weather Monitoring Sensors

The Model 014AWind Speed Sensor is an accurate, durable and economical anemometer suitable for a wide range of wind study applications. It is designed for long term unattended operation in most meteorological environments.

Range : 0 to 100 mph

Operation : For maximum operational reliability, the sensor uses a sealed magnetic read switch. This switch produces a series of contact closures at a rate proportional to wind speed. With its pulsed output, the Model 014A lends itself to applications involving both digital and analog measurement systems

Specifications:- Range: 0-100 mph , Starting Threshold: 1.0 mph

Accuracy: ±0.25 mph or 1.5% FS

Standard: Less than 15 ft (Metal Cup), Operating Range: -50°C to +70°C

Weight: 11 oz (.31 kg)

Contact Rating: 10 mA maximum

Wind Direction Speed

Page 34: Teledyne Analytical Instruments

34

Analytical Instruments for AQMS CO – GFC7001E

NO2 – 9110E

SO2 – 6400E

VOC – 4060

Ozone – 400E Particulate Matter (2.5 & 10) – Beta Ray Attenuation

Zero Air Generator – 701

Mass Flow Calibrator – 702E

WMS – Weather Monitoring Sensors

DAS – Win collect

Page 35: Teledyne Analytical Instruments

35

AAQMS – DAS Requirements A Data Acquisition System utilized in air quality and/or emissions monitoring

should do far more than simply collect data. It should provide a means for remotely checking the system and each

individual analyzer.

It should enable analyzers and calibration system to be configured remotely.

It should reliably log data directly from the instruments in digital form.

It should automatically warn the user of measurement exceedances or events such as calibration failures.

It should be easy to use.

Page 36: Teledyne Analytical Instruments

36

Teledyne – Win AQMS DAS WinAQMS is a Windows® based system which provides full control over the

entire system (remote and onsite) enabling automatic calibrations to be performed and system errors to be monitored.

WinAQMS interfaces to analyzers via a RS232 multi-drop serial link, through a USB link or via TCP/IP network link. This allows it to collect data directly from the instruments in digital format thus eliminating digital to analog and analog to digital conversion errors. The bi-directional interface also allows a remote central computer, running Teledyne WinCollect software, to access full control and diagnostics of the analyzers used and data to be collected remotely.

The Data Acquisition system has sufficient data storage to hold well over thirty years worth of historical data.

Page 37: Teledyne Analytical Instruments

37

Main Features : Win AQMS (DAS) Supports remote communication from anywhere in the world enabling full control over the pollution

monitoring system and direct interfacing with supported analyzers

Full control over calibration cycle periods

Remote communication through dial-up, Ethernet, satellite telephone networks, 3G network as well as short haul modems

Solid state hard disk drive eliminates risk of mechanical failure due to shock, high temperatures, vibration and harsh environments.

Data retrieval via USB Memory Stick or Mini SD card in the event communication networks are unavailable

"Industry Standard" RS232 and USB Communication enables digital communication with a wide range of supported monitoring equipment

Captures minimum, maximum, average values and standard deviations

Creates calculated channels that allows the user to apply calculations to data (logged automatically)

Fifth Generation Data Acquisition & Control System based on 30 years of field experience

Data storage space for over thirty years of 5 minute historical data

Lightning & surge protection facilities

Windows XP PRO Compatible ( WINDOWS 7 by default)

Page 38: Teledyne Analytical Instruments

38

Specifications : Win AQMS (DAS) CPU: ........ 1.6 Ghz+ RAM: 1 Gbytes

Operating System: Windows XP Data Storage Format: Data Stored in Ascii format

Hard Drive Config.: Solid State 64 Gbytes

Display Driver: Supporting up to 1929 x 1200 (allows dual screen

Data Averaging Periods: Up to 4 independent data sets Selectable between 1 minute and 7 days

Calibration control: Automatic Span and Zero control. Calibration data is stored separately

Communication ports: 1 RS232 /RS485 serial ports, 6 x USB2.0 Ports

Networking :1000 Base T Ethernet 802.11g WLAN

Power: 12 volts < 7 Watt power supply.

Size: 10.1 x 11.5 x 2.7 cm  370 grams

Page 39: Teledyne Analytical Instruments

39

AAQMS with DAS

Page 40: Teledyne Analytical Instruments

TELEYNE Team Thank you All

Company Confidential

Company Headquarters: City of Industry, California USA

Facility: 60,000 sq. ft. / ISO-9001:2008

Founded: 1945

Core Capabilities: Manufacturer of high quality measurement and control instrumentation.