Instructions
TNMS-M SURPASShiT 7020 3.1 LCT
User Manual
A42022-L5966-A 53-1-7619
-
7/27/2019 Tecnical Service 7020
2/203
ImportantNotice on ProductSafety
Elevated voltages are inevitably present at specific points in this electrical equipment. Some ofthe parts may also have elevated operating temperatures. Systems with forced ventilation haverotating items.Non-observance of these conditions and the safety instructions can result in personal injury orin property damage.The system complies with the standard EN 60950-1 / IEC 60950-1. All equipment connectedhas to comply with the applicable safety standards.Mount the systems in areas with restricted access only. Only trained and qualified personnelmay install, operate, and maintain the systems.
The same text in German:Wichtiger Hinweis zur ProduktsicherheitIn elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung.Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen. Anlagen mitZwangsbelftung haben drehende Teile.Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungenund Sachschden fhren.Das System entspricht den Anforderungen der EN 60950-1 / IEC 60950-1. AngeschlosseneGerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.Die Anlagen drfen nur in Betriebssttten mit beschrnktem Zutritt aufgebaut werden. DieAnlagen drfen nur durch geschultes und qualifiziertes Personal installiert, betrieben undgewartet werden.
Trademarks:All designations used in this document can be trademarks, the use of which by third parties fortheir own purposes could violate the rights of their owners.
-
7/27/2019 Tecnical Service 7020
3/203
Contents1 Notes on This Documentation1.1 Customer Documentation1.2 Complementary Documents1.3 Symbols Used in the Customer Documentation1.3.1 Symbol for Warnings1.3.2 Symbols for Notes1.3.3 Symbols for Menu Displays and Text Inputs1.4 Notes on Licensed Software
2 Introduction
3 Features
4 Hardware Configuration
5 Software Configuration
6 Installation6.1 Route Configuration6.2 Installing the LCT Software Package6.3 Uninstalling the LCT Software Package
7 Starting and Shutting down TNMS-M SURPASS hiT 7020 LCT7.1 Starting TNMS-M SURPASS hiT 7020 LCT7.2 Shutting Down TNMS-M SURPASS hiT 7020 LCT
8 Main Interface Features8.1 Main Window8.1.1 Title Bar8.1.2 Main Menu Bar8.1.3 Work Area8.2 Submenus (with Right Mouse Button Click)8.2.1 MainBoard Card8.2.2 Ethernet Card
9 NE Configuration and Management9.1 Chassis View
9.2 NE Property Configuration9.3 Shutting down NE9.4 NE Timing Setting9.5 FTP Settings9.6 NE Trap Destination Configuration9.7 DCC Transparent Configuration9.8 Embedded E1 DCC Configuration9.9 NE Software Management9.10 MIB Management
10 SDH Configuration and Management
10.1 Card Configuration and Management10.1.1 Card Properties Configuration
-
7/27/2019 Tecnical Service 7020
4/203
10.1.2 Synchronizing Card10.1.3 Delete Card10.1.4 Cold Reboot Card
10.1.5 Warm Reboot Card10.2 SDH Port Configuration and Management10.2.1 Port Configuration10.2.2 Port Status10.3 E1 Port Configuration and Management10.4 Cross-Connect Management10.4.1 Querying Current Cross-Connection10.4.2 Adding a New Cross-Connection10.4.3 Deleting a Connection10.5 Terminal Point Configuration and Management10.5.1 Querying Current Terminal Point10.5.2 Terminal Point Mapping10.6 Synchronization Management10.6.1 Global Settings10.6.2 Configuring the System Clock10.6.3 Configuring the Reference
11 Ethernet Configuration and Management11.1 Bridge Configuration11.2 LAN Card Configuration and Management11.2.1 LAN Port Properties11.2.2 VLAN Rate Limiting11.2.3 CoS Configuration11.3 WAN Port Configuration11.4 VLAN Management11.5 Priority Algorithm Configuration11.6 Static MAC Address Configuration11.7 ACL Configuration11.8 Group Broadcast Configuration11.9 RSTP Configuration
12 Protection Management12.1 SNCP Management
12.1.1 Viewing and Modifying SNCP12.1.2 Creating SNCP12.1.3 Deleting SNCP12.1.4 Switching SNCP12.2 MSP Management
13 Routing and Protocol Configuration13.1 IP Route Configuration13.1.1 IP Interface13.1.2 IP Static Route13.1.3 IP Routing Table
13.2 OSPF13.2.1 OSPF General
-
7/27/2019 Tecnical Service 7020
5/203
13.2.2 OSPF Areas13.2.3 OSPF Interfaces13.2.4 OSPF Interface Metrics
13.2.5 OSPF Neighbors13.2.6 OSPF LSDB13.2.7 OSPF Ext LSDB13.3 OSI Configuration
14 Maintenance14.1 Loopback Test Management14.1.1 Querying Loopback Status14.1.2 Setting Loopback Test14.2 LED Test
15 Performance Monitoring Management15.1 Overview of Performance Monitoring15.1.1 SDH Performance Monitoring15.1.1.1 PM in Regeneration Section (G.829)15.1.1.2 PM in Multiplex Section (G.829)15.1.1.3 PM for HP/LP (High Order and Low Order Paths) (G.829)15.1.1.4 PM for Pointer Justification Counts at Administrative Unit (G.707)15.1.2 Data Performance Monitoring Parameters15.2 SDH Performance Monitoring Management15.2.1 Filter Setting15.2.1.1 TP Filter
15.2.1.2
Parameter Filter15.2.2 Editing Monitored Parameter15.2.3 Alarm Threshold15.2.4 History SDH Performance15.3 Ethernet Performance Monitoring Management15.3.1 Filter Setting15.3.2 Editing Monitored Parameter15.3.3 Ethernet PM Thresholds15.3.4 History Ethernet Performance15.4 Current E1 Bit Slip Performance15.4.1 Filter Setting
15.4.2 Editing Monitored Parameter15.4.3 History E1 Bit Slip Performance
16 Alarm and Event Management16.1 Overview of Alarms16.2 NE Alarms16.2.1 Current Alarms16.2.2 Viewing Active Alarms16.2.3 Reviewing the current alarms16.2.4 Clearing Alarms16.2.5 Alarm Search
16.3 LED Indicators16.4 Exporting Alarms
-
7/27/2019 Tecnical Service 7020
6/203
16.4.1 Exporting Active Alarms to a File16.4.2 Printing Active Alarms16.5 Configuring Fault Management
16.5.1 Audio Alarm Configuration16.5.2 Alarm Type List Management16.6 Alarm Configuration for Single NE16.6.1 Alarm Inhibit Configuration16.6.2 Alarm Out Configuration16.6.3 MDI/MDO Configuration16.7 Displaying the Node Event Log16.7.1 Interpreting the Node Event Log16.7.2 Management Events16.7.3 Hardware Events16.7.4 Software Events16.7.5 Event Search
17 Resource and Database Management17.1 NE Usage Statistics
18 How To 18.1 Creating a TU12 Cross-Connection between STM-4 and STM-4/118.2 Configuring Layer 2 100Mbps Ethernet Service18.3 Monitoring Current Performance of STM-1 Port18.4 Creating Multiplex-Section Protection between Two NEs18.5 Creating SNCP Between Two NEs Using Two Ports of MainBoard (STM-4)
19 Abbreviations
20 Index
-
7/27/2019 Tecnical Service 7020
7/203
IllustrationsFig. 2.1 TNMS-M Series Products
Fig. 6.1 Open Hyper Terminal
Fig. 6.2 Hyper Terminal--Connection Description
Fig. 6.3 Hyper Terminal--Connect To
Fig. 6.4 Hyper Terminal--COM1 Properties
Fig. 6.5 CLI Window--Welcome to Login
Fig. 6.6 Main Manu
Fig. 6.7 User Table
Fig. 6.8 Edit a Given User
Fig. 6.9 IP Address Configuration
Fig. 6.10 Add Static Route Information
Fig. 6.11 TNMS-M SURPASS hiT 7020 LCT Welcome Screen
Fig. 6.12 License Agreement
Fig. 6.13 Select Destination Location
Fig. 6.14 Select Start Menu Folder
Fig. 6.15 Select Additional Tasks
Fig. 6.16 Ready to Install
Fig. 6.17 Installing
Fig. 6.18 Exit Setup
Fig. 6.19 Completing Setup
Fig. 6.20 Uninstall the Software from the Start Menu
Fig. 6.21 Dialog Box of Confirming the Uninstall Process
Fig. 6.22 Uninstall Status
Fig. 6.23 Completing the Uninstall Process
Fig. 7.1 Desktop Icon
Fig. 7.2 Start LCT from Start Menu
Fig. 7.3 Select Server IP
Fig. 7.4 LCT Login Window
Fig. 7.5 LCT Main Window
Fig. 8.1 Main Window
Fig. 9.1 Chassis View
Fig. 9.2 NE Properties
Fig. 9.3 Shutdown NE
Fig. 9.4 Shutdown Information
-
7/27/2019 Tecnical Service 7020
8/203
Fig. 9.5 NE Time Settings
Fig. 9.6 FTP Setting
Fig. 9.7 FTP Root
Fig. 9.8 NE Trap Destination
Fig. 9.9 Confirmation
Fig. 9.10 DCC Transparency Configuration
Fig. 9.11 Embedded E1 DCC Configuration
Fig. 9.12 NE Software Management
Fig. 9.13 FTP Setting
Fig. 9.14 NE Software Switch Result Windows
Fig. 9.15 MIB Management
Fig. 9.16 FTP Setting
Fig. 10.1 Card Properties
Fig. 10.2 Synchronize Card
Fig. 10.3 SDH Port Properties
Fig. 10.4 E1 Port Properties
Fig. 10.5 Cross-Connect Management
Fig. 10.6 Create Cross-Connect
Fig. 10.7 Confirming for Deleting the Selected Cross-Connections
Fig. 10.8 TP Configuration (View 1 - As Presented)
Fig. 10.9 TP Configuration (View 2 - Engaged)
Fig. 10.10 TP Multiplexing Structure Query
Fig. 10.11 TP Multiplexing Structure, View 1
Fig. 10.12 TP Multiplexing Structure, View 2
Fig. 10.13 Modify Mapping
Fig. 10.14 Synchronization Management, Timing Source of NE
Fig. 10.15 Global Settings
Fig. 10.16 System Clock, Switching Timing Sources
Fig. 10.17 Timing Source Reference Properties
Fig. 11.1 Bridge Properties
Fig. 11.2 LAN Port Configuration
Fig. 11.3 Rate Limit Config
Fig. 11.4 Change Cos
Fig. 11.5 WAN Port Configuration
Fig. 11.6 Bandwidth Configuration
Fig. 11.7 VLAN Management
-
7/27/2019 Tecnical Service 7020
9/203
Fig. 11.8 Modify VLAN Based on VLAN
Fig. 11.9 Modify VLAN Based on Ports
Fig. 11.10 Egress Priority Weight Config
Fig. 11.11 Output Priority Algorithm Configuration
Fig. 11.12 Modify Priority Weight
Fig. 11.13 Static MAC Address Configuration
Fig. 11.14 Add MAC Address
Fig. 11.15 ACL Config
Fig. 11.16 Add ACL
Fig. 11.17 Group Broadcast Configuration
Fig. 11.18 Add MAC Address
Fig. 11.19 RSTP Properties Configuration
Fig. 11.20 Port RSTP Configuration
Fig. 12.1 SNCP Management
Fig. 12.2 SNCP Properties
Fig. 12.3 Create Cross-Connect
Fig. 12.4 Create SNCP
Fig. 12.5 Delete SNCP
Fig. 12.6 SNCP Switch
Fig. 12.7 MSP Management
Fig. 12.8 MSP Property
Fig. 12.9 External Commands
Fig. 12.10 Create Linear Multiplex Section Protection Group
Fig. 13.1 IP Interface
Fig. 13.2 IP Static Route
Fig. 13.3 Edit IP Static Route
Fig. 13.4 Add IP Static Route
Fig. 13.5 IP Routing Table
Fig. 13.6 OSPF Submenu
Fig. 13.7 OSPF General
Fig. 13.8 OSPF Area
Fig. 13.9 Add OSPF Area
Fig. 13.10 Edit OSPF Area
Fig. 13.11 OSPF Interface
Fig. 13.12 OSPF Interface Metric
Fig. 13.13 OSPF Neighbor
-
7/27/2019 Tecnical Service 7020
10/203
Fig. 13.14 OSPF Link State Database
Fig. 13.15 OSPF External Link State Database
Fig. 13.16 OSI Configuration
Fig. 14.1 Loopback Test Management
Fig. 14.2 Loopback Test Configure
Fig. 14.3 LED Test
Fig. 15.1 SDH Current Performance
Fig. 15.2 Monitor Point Filter
Fig. 15.3 Select Terminal Point
Fig. 15.4 Edit Properties of Performance Monitor
Fig. 15.5 Alarm Threshold
Fig. 15.6 SDH History Performance
Fig. 15.7 Ethernet Current Performance
Fig. 15.8 Monitor Point Filter
Fig. 15.9 Select Port
Fig. 15.10 Edit Properties of Monitored Parameter
Fig. 15.11 1 Second Ethernet Thresholds
Fig. 15.12 Monitor Point Filter
Fig. 15.13 Select Ports
Fig. 15.14 Selected Ports
Fig. 15.15 Edit Properties of Performance Monitor
Fig. 15.16 Ethernet History Performance
Fig. 15.17 Current E1 Bit-Slip Performance
Fig. 15.18 Monitor Point Filter
Fig. 15.19 Select Port
Fig. 15.20 Selected Ports
Fig. 15.21 Edit Properties of Performance Monitor
Fig. 15.22 History E1 Bit Slip Performance
Fig. 16.1 Open Active Alarms from Main Menu
Fig. 16.2 Open Active Alarms from Right-click Menu
Fig. 16.3 Alarm Count by Severity
Fig. 16.4 Active Alarms
Fig. 16.5 Clear Alarm
Fig. 16.6 Alarm Search
Fig. 16.7 Alarm Source Config
Fig. 16.8 Active Alarm Search Result
-
7/27/2019 Tecnical Service 7020
11/203
Fig. 16.9 Report Alarm
Fig. 16.10 Report Window
Fig. 16.11 Save File
Fig. 16.12 Print Window
Fig. 16.13 Report Alarm Preview
Fig. 16.14 Print Setup
Fig. 16.15 Audio Alarm Config
Fig. 16.16 Alarm Type List Management
Fig. 16.17 Modify Property of Alarm
Fig. 16.18 Alarm Inhibit Configuration
Fig. 16.19 Alarm Out Configuration
Fig. 16.20 MDI/MDO Configuration: MDI Tab
Fig. 16.21 MDI/MDO Configuration: MDO Tab
Fig. 16.22 Events
Fig. 16.23 Event Search
Fig. 16.24 Event Search Result
Fig. 17.1 NE SDH Resource Usage Statistics
Fig. 18.1 TP Multiplexing Structure
Fig. 18.2 Query Result
Fig. 18.3 Expanding Tree Graph
Fig. 18.4 Mapping AU4 to TU12
Fig. 18.5 Result of Mapping
Fig. 18.6 Mapping TU12 to AU4
Fig. 18.7 Cross-Connect Management Menu
Fig. 18.8 Cross-Connect Management
Fig. 18.9 Create Cross-Conect
Fig. 18.10 Create Cross-Connect
Fig. 18.11 Bridge Configuration Menu
Fig. 18.12 Bridges Properties
Fig. 18.13 LAN Port Configuration
Fig. 18.14 WAN Port Config
Fig. 18.15 Bandwidth Configuration
Fig. 18.16 VLAN Management
Fig. 18.17 VLAN Config
Fig. 18.18 Query VLAN Information
Fig. 18.19 Create Cross-Connect
-
7/27/2019 Tecnical Service 7020
12/203
Fig. 18.20 Cross-Connect Management
Fig. 18.21 Current SDH Performance Menu
Fig. 18.22 SDH Current Performance
Fig. 18.23 Monitor Point Filter
Fig. 18.24 Select Terminal Point
Fig. 18.25 Monitor Point Filter
Fig. 18.26 SDH Current Performance
Fig. 18.27 Point-to-point System
Fig. 18.28 MSP Management
Fig. 18.29 Create Linear Multiplex Section Protection Group
Fig. 18.30 MSP Management
Fig. 18.31 SNCP Example
Fig. 18.32 SNCP Management
Fig. 18.33 Create and Config SNCP
Fig. 18.34 SNCP Protection in NE A
Fig. 18.35 SNCP Switch
-
7/27/2019 Tecnical Service 7020
13/203
TablesTab. 3.1 Feature List
Tab. 4.1 Minimum Hardware Requirements of TNMS-M SURPASS hiT 7020 LCT
Tab. 8.1 Main Menu Structure
Tab. 9.1 NE Properties
Tab. 9.2 NE Software Management Window Field Description
Tab. 10.1 Card Properties Window Field Description
Tab. 10.2 Port Configuration
Tab. 10.3 Port Status
Tab . 10.4 TP Management Parameters
Tab. 10.5 Tributary(Trib#) to KLM to Timeslot(TS#) Numbers Mapping
Tab. 12.1 SNCP Properties
Tab. 15.1 Regenerator Section SES threshold xx% (for BIP-8)
Tab. 15.2 Defects Resulting in a Near-end Severely Errored Second
Tab. 15.3 Defects resulting in a Far-end Severely Errored Second
Tab. 15.4 Multiplex Section SES threshold xx% (For BIP-1)
Tab. 15.5 Defects Resulting in a Near-end Severely Errored Second
Tab. 15.6 Defects Resulting in a Far-end Severely Errored Second
Tab. 15.7 Path Overhead Section SES Threshold xx% (For BIP-2, BIP-8)
Tab. 15.8 PM Management Functions
Tab. 15.9 Default Value and Value Range for a Fixed 15-minute Period
Tab. 15.10 Default value and Value Range for a Fixed 24-hour Period
Tab. 15.11 Maximum Records number of History Performance
Tab. 15.12 Primary Ethernet PM Function
Tab. 16.1 Active Alarms information
Tab. 16.2 LED Status
Tab. 16.3 Management Events
Tab. 16.4 Hardware Events
Tab. 16.5 Software Events
-
7/27/2019 Tecnical Service 7020
14/203
1 Notes on This Documentation
1.1 CustomerDocumentationThe Customer Documentation of the SURPASS hiT 7020 comprises the followingdescriptions and manuals:
TechnicalManual
The Technical Manual gives an overview of the application, performance features,interfaces, and functions of the SURPASS hiT 7020. It also contains the most importanttechnical data.
The Technical Manual does not contain any instructions to operate the product.
Installationand Test ManualThe Installation and Test Manual ITMN contains instructions on mounting, connecting,and commissioning the SURPASS hiT 7020, and connecting and commissioning theLCT operating terminals.
TroubleshootingManualThe Troubleshooting Manual provides information about the alarm list SUPRASS hiT
7020 supports and troubleshooting procedures.
TNMS-M SURPASShiT 7020LCTUser ManualThe LCT User Manual provides information about the LCT (features, configuration,installation, etc.) and how to operate, monitor, and maintain the SURPASS hiT 7020using the Element Manager software (Application Software) running on the LCT.
Besides the LCT User Manual, the OnlineHelp of the TNMS-M SURPASS hiT softwareis of high importance for the user.
1.2 ComplementaryDocumentsIn addition to the SURPASS hiT 7020 customer documentation listed in Chapter 1.1 , there isfurther documentation: SURPASShiT 7020ReleaseNote
This document identifies the specific version of the SURPASS hiT 7020 and providesinformation on HW, SW, LCT components and the limitations of the release as well asimportant notes concerning the customer documentation.
1.3
SymbolsUsedin the CustomerDocumentation
-
7/27/2019 Tecnical Service 7020
15/203
1.3.1 Symbolfor Warnings
This symbol identifies notes which, if ignored, can result in personal injury or inpermanent damage to the equipment.
1.3.2 Symbolsfor Notes
Information which extends beyond the immediate context.
Cross reference to other chapters in this manual or reference to other manuals.
Help Reference to the online help system of the Element Manager software.
1.3.3 Symbolsfor MenuDisplaysand Text Inputs
Menu options from pop-up menus or inputs to be made by the user (texts, commands) aredisplayed consecutively in their hierarchical sequence in pointed brackets:
etc.
1.4 Notes on LicensedSoftwareThis documentation refers to software products which were taken over from other companiesas licenses.
Should problems arise, the user should contact Siemens AG as the licensee and not therelevant licenser.
-
7/27/2019 Tecnical Service 7020
16/203
2 IntroductionTNMS-M series products are network management system which are used to manage andmaintain MSTP network elements built by SURPASS hiT series products.
The TNMS-M series network management system products include TNMS-M LCT andTNMS-M. (See Fig. 2.1)
Fig. 2.1 TNMS-M Series Products
TNMS-M LCT (Local Craft Terminal) provides NE level TNMS-M based managementfunction and GUI. One TNMS-M LCT application can only connect and manage one NE atone time. The interface between TNMS-M LCT and NE is SNMP based. Different typenetwork element corresponds to different type LCT, which is mainly used for on-sitemanagement and maintenances.
TNMS-M SURPASS hiT 7020 LCT is an element management system of single NE, which isdesigned to provide comprehensive fault, configuration, performance management functionsfor the SURPASS hiT 7020 product line.
-
7/27/2019 Tecnical Service 7020
17/203
3 FeaturesTNMS-M SURPASS hiT 7020 LCT features are listed in Tab. 3.1.
Feature Description
Java-Based User Interface Java-based user interface to connect NEs Provides Chassis View showing the front faceplate of
the equipment Color-coded LEDs to indicate NE status
Consistency and DataSynchronization
Uploads data from the actual NE to update themanagement information of NE in the LCT
Ensures all status and data in the LCT are consistentwith the actual NE
Network Element Control Enables NE software updates and download from the
LCT Redundant images of the embedded software are
stored in an NE, one active and one backup whichcan be switched and activated by LCT
NE warm reboot and cold reboot can be controlled byLCT
Configuration Management View/synchronize/delete/modify Circuit-pack
attributes View/synchronize/modify port attributes TP configuration and management, including
viewing/synchronizing/modifying TP attributes, TPmultiplexing structure configuration
SDH Cross-Connect configuration and management Timing configuration and management, including
select timing reference for system clock, modify/viewtiming reference of NEs system clock, and configuretiming reference for station clock
Virtual concatenation configuration and management LCAS configuration Ethernet VLAN configuration Ethernet Class of Service configuration Rapid spanning trees management Rate limiting configuration of Ethernet port Broadcast strom control Multicast management IP route configuration OSPF parameters configuration OSI-lite parameters configuration
Protection and Redundancy Supports MSP protection management Supports SNCP/I protection management Supports Ethernet RSTP protection management
-
7/27/2019 Tecnical Service 7020
18/203
Feature Description
Performance Management Supports monitored performance TPs and
parameters selection. Supports current performance management Supports history performance management
Maintenance Loopback Configuration for testing LED test
Fault Management Collects, displays, and manages SURPASS hiT 7020
fault messages (including NE, card, port and TPrelated)
Supports color coded alarms to indicate alarmseverity level
Supports active alarm synchronization
Event Management Supports NE related event management
Tab. 3.1 Feature List
-
7/27/2019 Tecnical Service 7020
19/203
4 Hardware ConfigurationThe TNMS-M SURPASS hiT 7020 LCT software can run on the following operating system: Microsoft Windows based operating system PC, Desktop or Laptop
The minimum hardware requirements of TNMS-M SURPASS hiT 7020 LCT are listed in Tab.4.1.
Configuration HardwareRequirement
Windows-Based Computer 1.6 GHz Pentium-4 Processor 512M RAM
1
20GB Hard Disk TP Ethernet 10/100BASE-T Networking Port Graphic Card with 1024 768 resolution (75Hz
refresh for Desktop; 60-Hz refresh for Notebook) Color Monitor (17 for Desktop; 14 TFT for
Notebook)Tab. 4.1 Minimum Hardware Requirements of TNMS-M SURPASS hiT 7020 LCT
-
7/27/2019 Tecnical Service 7020
20/203
5 Software ConfigurationThe following operating system and software package are required to install and run theTNMS-M SURPASS hiT 7020 LCT.
MicrosoftWindowsbasedoperatingsystem
Windows 2000 Professional operating system, or
Windows XP Professional operating system
The TNMS-M SURPASShiT 7020 LCT software
-
7/27/2019 Tecnical Service 7020
21/203
6 Installation
6.1 Route ConfigurationTNMS-M SURPASS hiT 7020 LCT manages NEs based on TCP/IP addresses. Therefore,the user must set a static route to enable the LCT system to find the NE. Before setting theroute, ensure that the console port and the MGMT port of the users computer are connectedwith the peer ports of SURPASS hiT 7020.
TNMS-M SURPASS hiT 7020 LCT only supports NE management by the MGMTport.
1. Click to open the window. (See Fig. 6.1)
Fig. 6.1 Open Hyper Terminal
-
7/27/2019 Tecnical Service 7020
22/203
2. In the window, enter the user name in the field andclick .
Fig. 6.2 Hyper Terminal--Connection Description
3. In the window, choose (the computers connected consoleport) in the drop-down menu and click .
-
7/27/2019 Tecnical Service 7020
23/203
Fig. 6.3 Hyper Terminal--Connect To
4. In the window, click and click .
Fig. 6.4 Hyper Terminal--COM1 Properties
-
7/27/2019 Tecnical Service 7020
24/203
5. Input a few and the CLI interface window will be shown as follows. (See Fig.6.5) Input the user name and the password, and then press . The user name is and the password is none.
Fig. 6.5 CLI Window--Welcome to Login
6. The Main Menu will be shown. (See Fig. 6.6)
Fig. 6.6 Main Manu
-
7/27/2019 Tecnical Service 7020
25/203
7. User Table
Press from the Main Menu and the User Table will be shown. (See Fig. 6.7). The UserTable enables the user to add/delete/modify the user information.
Fig. 6.7 User Table
8.
Press from the User Table to edit a given user.
Fig. 6.8 Edit a Given User
-
7/27/2019 Tecnical Service 7020
26/203
9. IP Address Configuration
Press from the Main Menu to configure the node IP address, the management port IPaddress, the management port subnet mask, and the default gateway for the management
port.The user can select 1 to 4 to configure the special IP address based on his/her needs.
Fig. 6.9 IP Address Configuration
-
7/27/2019 Tecnical Service 7020
27/203
10. Click to open the window, and then use the command to enter the static route information. For example, enter the
command to add thestatic route information into the users computer; that means the added routes IP address is192.168.16.243, the mask is 255.255.255.255, and the gateway is 192.168.12.243. (See Fig.6.10)
Note: The user can use the command to get more information about the command.
Fig. 6.10 Add Static Route Information
6.2 Installingthe LCT SoftwarePackageAfter selecting the SURPASS hiT serial products, Siemens post sales engineers andtechnical support technicians will help to complete selecting and installing hardware andsoftware based on requirements. A TNMS-M SURPASS hiT 7020 LCT installation CD will beprovided. Install the LCT software package on the provided CD using the wizard mode onany qualified operating system.
To describe how to install the LCT software package, the following example is provided.
-
7/27/2019 Tecnical Service 7020
28/203
1. Double-click the icon of TNMS_M_SURPASS_hiT7020_R31L13_setup.exe. Awelcome screen will be shown. (See Fig. 6.11) Then click to continue.
Fig. 6.11 TNMS-M SURPASS hiT 7020 LCT Welcome Screen
2. In the window, choose , and click to continue.
Fig. 6.12 License Agreement
-
7/27/2019 Tecnical Service 7020
29/203
3. Accept the default destination location, and click to continue. (See Fig. 6.13)
Note: The TNMS-M SURPASS hiT 7020 LCT software will be installed by default inthe %SystemDrive%\Siemens\hiT7020 folder. (%SystemDrive% specifies the drive letter ofthe hard disk drive containing the Windows operating system.) For example: If Windows isinstalled in Drive C, the software will be installed in the C:\Siemens\hiT7020 folder.
-
7/27/2019 Tecnical Service 7020
30/203
Fig. 6.13 Select Destination Location
4. Accept the default Start Menu folder location, and click to continue. (See Fig.6.14)
Fig. 6.14 Select Start Menu Folder
-
7/27/2019 Tecnical Service 7020
31/203
5. In the window, there are two options: A: and B: . The default option is A, and both options maybe selected. Click after the selection.
Fig. 6.15 Select Additional Tasks
6. After reviewing installation choices, click to proceed or to go back formaking changes.
-
7/27/2019 Tecnical Service 7020
32/203
Fig. 6.16 Ready to Install
7. The software will now be installed. (See Fig. 6.17)
Fig. 6.17 Installing
At any steps of 1-7 above, click and the window will be shown. (See
8. Fig. 6.18) Click to exit setup. Click to continue the installation.
Fig. 6.18 Exit Setup
9. To finish the installation, click . It is recommended that do not select the option.
-
7/27/2019 Tecnical Service 7020
33/203
Fig. 6.19 Completing Setup
6.3 Uninstallingthe LCT SoftwarePackage1. Click , select , select ,and click .
Fig. 6.20 Uninstall the Software from the Start Menu
-
7/27/2019 Tecnical Service 7020
34/203
2. Select to remove TNMS-M SURPASS hiT 7020 R3.1 LCT. (See Fig. 6.21)
Fig. 6.21 Dialog Box of Confirming the Uninstall Process
3. If is selected, an window will be shown. (Fig. 6.22)
Fig. 6.22 Uninstall Status
4. After the uninstalling complete, a confirmation window box will be shown. Click to
finish the uninstall process. Some items could not be removed automatically, but can beremoved manually from the installation folder (%SystemDrive%\Siemens\hiT7020 bydefault).
Fig. 6.23 Completing the Uninstall Process
-
7/27/2019 Tecnical Service 7020
35/203
7 Starting and Shutting down TNMS-M SURPASS hiT 7020LCT
7.1 StartingTNMS-M SURPASShiT 7020 LCTAfter the TNMS-M SURPASS hiT 7020 LCT software is installed, there are two methods tostart the TNMS-M SURPASS hiT 7020 LCT:
Option 1:
If the option is selected during the installation process, a icon will be shown on Desktop. (See Fig. 7.1) Double-click the
icon to start the LCT program.
Fig. 7.1 Desktop Icon
Option 2:
Select , and click the icon to start the LCT program. (See Fig. 7.2)
Fig. 7.2 Start LCT from Start Menu
-
7/27/2019 Tecnical Service 7020
36/203
Then the LCT program will start. During this process, a DOS window will be shown. (SeeFig. 7.3) Select the users server IP which can communicate with the NE. (The user can runthe IPCONFIG command in the Servers DOS window and will get Servers IP address.)
Fig. 7.3 Select Server IP
Note:
I. If the Network adapter of the computer has more than one IP addresses, the LCTprogram will ask the user to set IP address.
II. The users server IP address should be different from the server IP address of TNMS-M.If they use the same IP address, the LCT program cannot be started if TNMS-M isrunning.
Wait for a few seconds and the LCT login window will be shown. (See Fig. 7.4) Input LCTsLogin Name, Password and NEs Node IP Address which can be communicated with. Thenclick .
-
7/27/2019 Tecnical Service 7020
37/203
Fig. 7.4 LCT Login Window
For example, the user can login TNMS-M SURPASS hiT 7020 LCT using account:
Login Name: root
Password: public
The password can be changed in the LCT program.
Note:
I. The NE will disconnect from the LCT program when the NE is restarted. The LCTprogram will re-connect to the NE automatically after the NE is restarted. To connectmanually, the user needs to wait at least 40s after the NE is restarted.
II. The LCT program cannot connect to the NE which has been managed by the TNMSserver launched on the same host.
III. There is no READ/WRITE access control policy implemented between TNMS-M and theLCT program.
After successfully connecting to the NE, the LCT main window will be shown. (See Fig. 7.5)
-
7/27/2019 Tecnical Service 7020
38/203
Fig. 7.5 LCT Main Window
7.2 ShuttingDownTNMS-M SURPASShiT 7020 LCTThere are two methods to shut down TNMS-M SURPASS hiT 7020 LCT:
Option 1: Click the at top right of the TNMS-M SURPASS hiT 7020 LCT main window.
Option 2: Click .
A confirmation window will be shown. Click to confirm the shutdown request.
-
7/27/2019 Tecnical Service 7020
39/203
8 Main Interface Features
8.1 Main WindowThe main window (See Fig. 8.1) consists of the following elements:
Title Bar
Main Menu Bar
Work Area
Fig. 8.1 Main Window
8.1.1 Title Bar
The title bar is located at the top of the main window (See Fig. 8.1)
The title bar contains:
Leftmost, a special window symbol.
The type designation of the network element.
-
7/27/2019 Tecnical Service 7020
40/203
8.1.2 Main MenuBar
The main menu bar is located at the top of the main window, below the title bar (See Fig.8.1). It contains the main menu.
The drop-down menu items will be changed when different object (for example: anNE, a card, or a port) is selected in chassis view.
Before the TNMS-M SURPASS hiT 7020 LCT is connected to the NE, the drop-down menuhas only one button shown: , which has four functions: , , , and .
System Working with the softwareConnect Allow t the TNMS-M SURPASS hiT 7020 LCT to connect with NE
ChangePassword Change current password of LCT About Show the information about TNMS-M SURPASS hiT 7020 LCT Exit Close the main window of the NE application software, thus ending the session
After the TNMS-M SURPASS hiT 7020 LCT is connected to the NE, the main menubar shows seven drop-down menus: , , , , , , and .
System Working with the software
Disconnect Disconnect LCT from NEChangePassword Change current password of LCTAbout Show the information about TNMS-M SURPASS hiT 7020 LCTAudioAlarmConfig Manage all audio alarm, including melody type and play timesExit Close the main window of the NE application software, thus ending the session
Configuration Working with the NE configuration
NE PropertyConfiguration View and modify the properties of NECard PropertyConfiguration View and modify the properties of Card
Note: Only when a card in chassis is highlighted, would this menu item bedisplayed
WarmRebootNE Restart NE under the LCT systemCold RebootNE Restart NE and will cause traffic lossShutdownNE Close NE safelySDHPort PropertyConfiguration View and modify the properties of SDH Port
Note: Only when an SDH port in chassis is highlighted, would this menu item bedisplayed
E1 Port PropertyConfiguration View and modify the properties of E1 PortNote: Only when an E1 port in chassis is highlighted, would this menu item be
displayedTP Configuration View and modify all TP Properties
-
7/27/2019 Tecnical Service 7020
41/203
TP MultiplexingStructure View and modify the construction of TPsCross-ConnectManagement Manage all cross- connections in the NESynchronizationManagement Set and manage the timing references
NE TimeSetting Set time zone and the time of NESNCPManagement Create and manage SNCPMSPManagement Create and manage MSPNE FTP Configuration Set FTP server addressNE Trap DestinationConfigure Show and manage all IP addresses of PCs on which LCTs are running, current
managed NE will send trap to all those LCTNE SoftwareManagement Update, backup, and switch NE softwareNE MIB management Manage NE databaseAlarmInhibit Configuration Set system alarmAlarmOut Configuration Set system alarmMDI/MDOConfiguration Set MDI/MDO
DCCTransparentConfiguration Configure DCC TransparentEmbeddedE1 DCCConfiguration Configure DCC channelsNE ResourceUsageStatistics View the cards and ports in Mainboard and their usages; Data card is not listedRefreshChassis Display the latest state of NEsSynchronizeCard Synchronize a selected card
Note: Only when a card in chassis is highlighted, would this menu item bedisplayed
OSI Configuration Configure OSIIP RouteConfiguration Configure IP RouteOSPF Manage OSPF
Fault Managing Alarm
ActiveAlarms Display current alarms occur on NE/Card/Port according to managedobject selected currently
Events Display all events about the operationNote: only when neither a card nor a port in chassis is highlighted,would this menu item be displayed
AlarmSearch Search and display alarmsEventSearch Search and display eventsAlarmTypeList Management Manage alarm type
Performanceand Statistics View the status of NECurrentSDHPerformance View and manage current SDH performanceHistorySDHPerformance View and manage history SDH performanceCurrentEthernetStatistics View and manage current Ethernet performanceEthernetPM Thresholds Set Ethernet performance thresholdsHistoryEthernetStatistics View and manage history Ethernet performanceCurrentE1 Bit Slip Performance View and manage current E1 Bit Slip performanceHistoryE1 Bit Slip Performance View and manage history E1 Bit Slip performance
Maintenance Working with the maintenance test
LoopbackTest Management Perform Loop-back test
-
7/27/2019 Tecnical Service 7020
42/203
LEDTest Perform LED test
Windows Select the view for the open windows
SURPASShiT7020ChassisView List of all the currently-open windows; the selected window (in theforeground) is indicated by the tick
MinimizeAll Minimizes all opened windowsMaximizeAll Maximizes all windows
Help Online help( in English) conforming to MS Windows
OnlineHelp Display the help topics in the form of the and folders
Tab. 8.1 Main Menu Structure
8.1.3 Work Area
This range of the main window (See Fig. 8.1) shows all the windows which have just beenopened.
All windows within the work area can be opened or closed without the application softwareending (function of Windows).
In the Alarm Count area, all current alarm are collected and the number are listed by severityand category.
8.2 Submenus(with Right MouseButtonClick)The menu sequence which is described here depends on the selected card.
8.2.1 MainBoardCard
After selecting the STM card or CC card, click right button.
Card PropertyConfiguration Opens Card Properties window
SynchronizeCard Opens Synchronize window
Cross-ConnectManagement Opens Cross Connection Management window
SynchronizationManagement Opens Timing Source Management window
ActiveAlarms Opens Active Alarm window
NE PropertyConfiguration Opens NE Properties window
RefreshChassis Refresh the chassis view
SynchronizeNE Synchronize NE
ChangeNE IP Opens Configure NE IP window
8.2.2 EthernetCard
After selecting the Ethernet card, click right button.
-
7/27/2019 Tecnical Service 7020
43/203
Card PropertyConfiguration Opens Card Properties window
SynchronizeCard Opens Synchronize windowBridgeConfiguration Opens Bridge Properties window
LANPorts PropertyConfiguration Opens LAN Port Properties window
WANPortsPropertyConfiguration Opens WAN Port Config window
VLANManagement Opens VLAN Management window
EgressPriority WeightConfig Configure Egress Priority Weight
Static MACAddressConfiguration Opens Static MAC Address Config window
ACLConfiguration Opens ACL Config window
GroupBroadcastConfiguration Opens Group Broadcast Config window
RSTPConfiguration Opens RSTP Property Configuration window
ActiveAlarms Opens Active Alarms window
Cold RebootCard Restart Card
-
7/27/2019 Tecnical Service 7020
44/203
9 NE Configuration and ManagementBefore performing actions on TNMS-M SURPASS hiT 7020 LCT, the LCT must beconnected to an NE.
9.1 ChassisViewWhen TNMS-M SURPASS hiT 7020 LCT is connected to an NE, the NE Chassis view willbe displayed, which shows the real-time status of the NE. (See Fig. 9.1)
Fig. 9.1 Chassis View
For example, when the second card from the right side in Fig. 9.1 is plugged in, the green warning will be marked on the card. If the card is pulled out, the red warning will be marked on the card.
In this view, the user can see a total representation of the current node status, including agraphical view of all the slots, the card functions, the card types, the status of individualports, the power status, and other NE functions. The user can modify node properties in theconfiguration windows. The configuration windows can be opened from the main menu baror the right-click menu of the chassis view.
Select to refresh the chassis view.
9.2 NE PropertyConfigurationTo open the window, select from the main menu.
The window will be shown. (See Fig. 9.2)
-
7/27/2019 Tecnical Service 7020
45/203
Fig. 9.2 NE Properties
Each item in the window is described in the following table. (See Tab. 9.1)
Item DescriptionNE Label This is used to distinguish different nodesSerial Number The serial number of this node configured by the manufacturerLocation The physical position of this node in real-lifeSystem Mode The current system mode of this node (which one cannot be modified
from this window). Description The user uses this to field to input his/her own detailed description of
this nodeVersion The hardware version of this node.Contact The contact or owner of this nodeIP Address The IP address of this node
Subnet Mask The subnet mask of this nodeGateway The gateway of this node
-
7/27/2019 Tecnical Service 7020
46/203
Item DescriptionDate/Time The current time on this nodeCard List The simple information of all the cards on this node. The user can
access the card configuration window by double-clicking thecorresponding line in the table.
Tab. 9.1 NE Properties
The user can change the properties of a node, but modifications are completed onlyafter the button has been clicked.
Click to confirm all the modifications and to quit the window.
If some of the properties are changed, click the button to check the latest status
of this node.Click to print the information of this node.
Click to quit the window. All unsaved modifications will be lost.
Click to launch the online help.
9.3 ShuttingdownNEFrom the main menu, select (See Fig. 9.3)
Fig. 9.3 Shutdown NE
-
7/27/2019 Tecnical Service 7020
47/203
Fig. 9.4 Shutdown Information
Click to confirm shutting down this NE.
9.4 NE TimingSettingOpen the corresponding chassis view.
From the main menu, select .
An window will be shown. (See Fig. 9.5)
-
7/27/2019 Tecnical Service 7020
48/203
Fig. 9.5 NE Time Settings
In the drop-down menu of , the protocol can be set or.
Under , select the corresponding NE whose time will be modified.In the drop-down menu of , the current time can be viewedmanually.
Click to check the latest information on setting time.
Click to confirm the modifications.
Click to quit the window, all the unsaved modifications will be lost.
Click to launch the online help
9.5 NE FTP Configuration
-
7/27/2019 Tecnical Service 7020
49/203
The FTP Settings can get the latest software and data support from the FTP server. Toperform NE software management, MIB management, the user needs to configure first theTNMS-M FTP setting as well as the FTP server.
Use the following steps to apply FTP Settings:Select from the main menu. The window will be shown with the current FTP settings. (See Fig. 9.6)
Fig. 9.6 FTP Setting
To modify the current configuration in the section:
Input the FTP servers IP address in the field.
Input the FTP username in the field.
Input the FTP user password in the field.
Note: Both of username and password are by default.
All the latest software and data of FTP server are stored in the
folder (%Install_Drive% specifies the drive letter of the hard disk drive containing the LCTprogram). For example, if the LCT program is installed in Drive C, the FTP root will be the folder. (See Fig. 9.7)
-
7/27/2019 Tecnical Service 7020
50/203
Fig. 9.7 FTP Root
The data of the user will be stored in the corresponding folders under the folder. For example, the MIB files uploaded from the LCTprogram will be stored in the folder.
Click to update the current configuration.
Click to confirm the modification.
Click to quit the window. All unsaved modifications will be lost.
Click to launch the online help.
Note: The configuration of the FTP server should be the same as the real FTP serversettings. Generally, the LCT server and the FTP server are on the same physical machine.The case that LCT server and FTP server are on different machine is also supported.
9.6 NE Trap DestinationConfigurationSelect . An window will be shown. (See Fig. 9.8)
-
7/27/2019 Tecnical Service 7020
51/203
Fig. 9.8 NE Trap Destination
The function of each button is described as follows:
Click to set a selection in the window.Click , a confirmation window will be shown. (See Fig. 9.9)
Click to update current NE Destination.
Click to quit the window without saving any modifications.
Click to launch the online help.
Fig. 9.9 Confirmation
9.7 DCCTransparentConfigurationIn the chassis view, select . The window will be shown. (See Fig. 9.10)
-
7/27/2019 Tecnical Service 7020
52/203
Fig. 9.10 DCC Transparency Configuration
In the drop-down menu, select to enable loopbackfunction or select to disable loopback monitor.
Click to confirm the settings.Click to quit this dialog.
Click to launch the online help.
9.8 EmbeddedE1 DCCConfigurationIn the chassis view, select . The window will be shown. (See Fig. 9.11)
-
7/27/2019 Tecnical Service 7020
53/203
Fig. 9.11 Embedded E1 DCC Configuration
In this window, two DCC channels can be configured. Select or in theDCC Channel dropdown menu to enable or disable this E1 DCC channel. Checkcorresponding card, port, CTP, and protocol in the drop-down menus.
Click to check the latest information.
Click to confirm the modification without closing the window.
Click to confirm the modification if you want this window closed.
Click to quit this dialog. All the unsaved modifications will be lost.
Click to launch the online help
9.9 NE SoftwareManagementTwo software images can be stored in the TNMS-M SURPASS hiT 7020 LCT, an activeimage and a backup image. Using the LCT, the user can download a TNMS-M SURPASShiT 7020 NE software image to the NE as the backup version from the FTP server or theuser may switch software images between active and backup versions.
NE software management is done by the steps below:
-
7/27/2019 Tecnical Service 7020
54/203
From the main menu, select . The window will be shown. (See Fig. 9.12)
Fig. 9.12 NE Software Management
Each field in the window is described as follows. (See Tab. 9.2)
Fields Description
Active Software Version The NE software version currently running
Backup Software Version The backup NE software version
State of Last Command The last command status
Tab. 9.2 NE Software Management Window Field Description
Click to open the window. (See Fig. 9.13)
-
7/27/2019 Tecnical Service 7020
55/203
Fig. 9.13 FTP Setting
Input the corresponding information in the , , and fields.
Click to refresh the information.
Click to confirm the modifications.
Click to quit the window. All unsaved modifications will be lost.
Click to launch the online help.
In the window, input the NE software file name on the FTPserver in the field, and click to downloadthe software image to the NE as the backup software version from the FTP server.
Click to switch the software images between the active version and the backupversion.
Click to close the window. All the unsaved modifications will be lost.
Click to refresh the information.
Click to launch the online help.In the window, input the NE software file name on the FTPserver in the field, and click to downloadthe software image to the NE as the backup software version from the FTP server.
Click to switch the software images between the active version and the backupversion. After Switch process finished the will pop-up to prompt users tocold reboot or warm reboot the NE. (See Fig. 9.14)
-
7/27/2019 Tecnical Service 7020
56/203
Fig. 9.14 NE Software Switch Result Windows
NOTE:1) System cold reboot (system initialization) takes 3 minutes to complete. It is suggested
that no other operations (such as card insertion or pull-out, system power-on or power-off) be performed during the system initialization.
2) System cold reboot will cause traffic hit. The traffic hit time is about 30 second,maximum 3 minutes.
3) System warm reboot process takes 2 minutes. It is suggested that no operations (suchas card insertion or pull out, system power on or power off) be performed during systemreboot.
4) Card reset will impact the traffic passing through this card. The traffic hit time is about30 seconds (maximum 60 seconds).
Click to close the window. All the unsaved modifications will be lost.
Click to refresh the information.
Click to launch the online help.
Note: Make sure that the FTP server settings and the software image path arecorrectly configured before the operation is launched.
9.10 NE MIB ManagementThe SURPASS hiT 7020 MIB consists of the internal databases/files in the NE that store allthe NE configurations and runtime status information. There are two versions of MIB filesstored in the NE: an active version and a backup version, all the MIB management functionscan be performed by using the LCT.
Following the steps below to perform MIB management:
From the main menu, select . The window will be shown. (See Fig. 9.15)
-
7/27/2019 Tecnical Service 7020
57/203
Fig. 9.15 MIB Management
Click to open the window. (See Fig. 9.16)
Fig. 9.16 FTP Setting
Input the corresponding information in the , , and fields.
Note: Both of username and password are by default.
Click to refresh the information.
Click to confirm the modifications.
Click to quit the window. All unsaved modifications will be lost.
Click to launch the online help.
-
7/27/2019 Tecnical Service 7020
58/203
In the window, to upload the MIB files from the NE to the FTP server,input the directory in which the MIB files will be saved on the FTP server in the field, and then click .
To download the MIB files from the FTP server to the NE, input the directory in which theMIB files exist in the field, and then click .
To activate the backup MIB version, click . This operation will activate the backupMIB version.
When MIB switch is executed, the network management system reminds user toWarm reboot or Cold Reboot the system based on the system operation manual. Theuser should reboot the system immediately. Before system reboot (after the MIB isswitched), any NE operation will not be saved into MIB; therefore, any operation before
system reboot is invalid.
The field shows the state of the last command. Click toget the value of State of Last Command field.
-
7/27/2019 Tecnical Service 7020
59/203
10 SDH Configuration and Management
10.1 Card Configurationand ManagementIn the chassis view, the card selected becomes framed in blue.
There are two methods to open the card configuration window in chassis view:
Right-click the card, select , or
Select the card, and select from themain menu.
A window will be shown. (See Fig. 10.1)
10.1.1 Card PropertiesConfiguration
A typical window for card properties is shown below:
Fig. 10.1 Card Properties
Each field in the window is described as follows. (See Tab. 10.1)
-
7/27/2019 Tecnical Service 7020
60/203
Fields Description
Slot Number The slot this card has been plugged into.
Card Function The function of the card. The function of the card will also beshowed in the chassis view, on the right top corner of thiscard, and in a floating window box after the mouse has beenpointing on the card for a while.
Card Type The type of the card, such as, STM-64, STM-16, STM-4,STM-1, UDC, GE, FE, MC, CC, etc.
Card State The current state of this card
Card Serial Number The serial number of this card
Card Label This is used to distinguish different cards easily
Boot Image Version The version of the boot serverBoot Image Date The time, when the boot server started
Hardware Version The version of this card.
Temperature Threshold The threshold setting for the temperature alarm. When thetemperature of this card is over the threshold, an alarm willbe raised.
Temperature ClearThreshold
When the temperature has fallen below the temperatureclear threshold, the temperature alarm will be automaticallycleared.
S Code The S code of this card
Port list The list of all ports on this card.Tab. 10.1 Card Properties Window Field Description
If any properties of a card have been modified, the button must be used to validatethese changes. And only after clicking this button, will the modification been completed.
When viewing the card options and not changing properties of the card, click tocheck the latest status of the card.
Click to print the information on this card.
Click to quit the window. All the unsaved modifications will be lost.
Click to launch the online help.
10.1.2 SynchronizingCard
Right-click the corresponding card in the chassis view and select . Orchoose the card and select from the main menu. Aconfirmation window will be shown. (See Fig. 10.2)
-
7/27/2019 Tecnical Service 7020
61/203
Fig. 10.2 Synchronize Card
Click to start the synchronization process.
Click to cancel the synchronization process.
10.1.3 Delete Card
When the card has an absent status, right-click it and select in the pop-upmenu. Then click in the pop-up warning window to confirm the deletion command, orclick to cancel this operation.
10.1.4 Cold RebootCard
Right-click a card and select in the pop-up menu, or highlight a cardand select . Then click in the pop-up warningwindow to confirm the command, or click to cancel this operation.
10.1.5 WarmRebootCardRight-click a card and select in the pop-up menu, or highlight a cardand select . Then click in the pop-up warningwindow to confirm the command, or click to cancel this operation.
10.2 SDHPort Configurationand ManagementThere are three ways to open the window:
In the Chassis View, choos e the corresponding port. Right-click, and select
. Choose the corresponding port, and select from the main menu.
Open the port configuration in the window, and double-clickthe line of the port to view or configure in the .
The window will be shown. (See Fig. 10.3)
-
7/27/2019 Tecnical Service 7020
62/203
Fig. 10.3 SDH Port Properties
There are two parts in this window: and . Each parameterin this window is described below. Generally, the user can only change some parameters inthe Port Configuration part.
10.2.1 Port Configuration
Fields Descriptions
Port Type This identifies the type of port
Port Label A user can change this field to distinguish among ports
-
7/27/2019 Tecnical Service 7020
63/203
Port Mode There are three modes:
Auto mode: The system decides the optimum mode for
this port.Monitor mode: When an alarm is generated from thiscard, it will be automatically reported to the alarmmanagement.
Non-monitor mode: No matter how many alarms aregenerated from this card, none of them will be reported.
Port Admin Mode There are two Port Admin Modes:
Enable (connected), or
Disable (unconnected)
Auto Laser Shutdown
-
7/27/2019 Tecnical Service 7020
64/203
Click to print the information of this port.
Click to quit the window. All the unsaved modifications will be lost.
Click to launch the online help.
10.3 E1 Port Configurationand ManagementThere are three ways to open the window:
In the Chassis View, choose the corresponding port. Right-click, and select .
Choose the corresponding port, and select from the main menu.
Open the port configuration in the window, and double-
click the line of the port to view or configure in the .The window will be shown. (See Fig. 10.4)
Fig. 10.4 E1 Port Properties
Can be set as auto, monitored, or non-monitored.
Can be set as Enabled, or Disabled.
Click to check the real-time E1 port properties.
Click to accept modifications in the window.
Click to confirm changes and quit the window.
Click to quit the window without saving any modifications.
-
7/27/2019 Tecnical Service 7020
65/203
Click to print the information of the E1 Port.
Click to launch the online help.
10.4 Cross-ConnectManagementTo manage all cross-connection in the NE, open the window, there are two methods to open this window:
1. Select from the main menu.
2. Right-click the cross-connect device card in the chassis view and select in the pop-up menu.
The window will be shown. (See Fig. 10.5)
Fig. 10.5 Cross-Connect Management
Use this window to query, add, or delete cross-connection.
10.4.1 QueryingCurrentCross-ConnectionUsually there are many Cross-Connections established within one NE. TNMS-M SURPASShiT 7020 LCT provides a method of easily viewing them by providing a Query function.
Input querying parameters
There are several selectable parameters to restrict the range of Cross-Connect, including (), (), , , ,and .
Select these parameters from the drop-down menus to find the Cross-Connect of interest,i.e. the target Cross-Connect.
After choosing a specific Source Card or Sink Card, manually choose the port to restrict theCross-Connect to a more limited range.
-
7/27/2019 Tecnical Service 7020
66/203
Input a specific Circuit Label to go to those Cross-Connections directly.
Click to view all Cross-Connections which satisfy the chosen conditions.
When the mouse moves to a Cross-Connection, the tool tips feature will be shown.
Click to print the information.
Click to launch the online help.
10.4.2 Addinga NewCross-Connection
Click to add a Cross-Connection; a window will beshown. (See Fig. 10.6)
Fig. 10.6 Create Cross-Connect
Choose the Cards and Ports between which a Cross-Connection is to be created; allavailable TPs (See Fig. 10.6) will be listed.
Click to sort the TPs in the list by tributary, and then button will bechanged to .
-
7/27/2019 Tecnical Service 7020
67/203
Click to sort the TPs in the list by timeslot, and then the button will bechanged to .
Choose the source and the destination TPs, and click .
The and buttons can only be used if two available ports have been selected.
Click to confirm the addition without closing the window and allowing additionalcross-connections to be made.
Click to confirm the changes and close the window.
Click to exit the window.
Click to launch the online help.
10.4.3 Deletinga Connection
In the window, the user can selectively delete cross-connections.
Click , a warning window will be shown.
Fig. 10.7 Confirming for Deleting the Selected Cross-Connections
Click to confirm the deletion.
Click to cancel the deletion.
10.5 TerminalPoint Configurationand Management
10.5.1 QueryingCurrentTerminalPoint
Select .
The window will be shown. (See Fig. 10.8)
-
7/27/2019 Tecnical Service 7020
68/203
Fig. 10.8 TP Configuration (View 1 - As Presented)
Select the card and port to be checked, or select All Cards or All Ports to check all the TPson cards and ports.
Click to check the TPs. (See Fig. 10.9)
-
7/27/2019 Tecnical Service 7020
69/203
Fig. 10.9 TP Configuration (View 2 - Engaged)
Select and view the TP to be modified and make desired changes to TP properties. Theproperties of this TP will be showed in the right panel.
Every parameter is described in the table below.
Fields Descriptions
TP Alarm Mon Can be set as Monitored or Non-Monitored
TIM Enable Can be set as permitted or prohibitedTI Trans Mode Can be set as 16-byte, Fixed 1-byte, Provisioned 1-byteTI Rec Mode Can be set as 16-byte, Fixed 1-byte, or provisioned 1-byteTransmitted TI Shows the transmitted TIAccepted TI Shows the accepted TI, cannot be changedExpected TI Shows the expected TISL Enabled Can be set as Yes or NoTransmitted SL Shows the transmitted SLAccepted SL Shows the accepted SLExpected SL Can be set to various values.DEG Enable Can be set as permitted or prohibited.
DEG Threshold The value can be set between 10exp(-5) and 10exp(-9)EXC Enable Can be set as permitted or prohibited.
-
7/27/2019 Tecnical Service 7020
70/203
EXC Threshold The value can be set between 10exp(-3) and 10exp(-5)Tab . 10.4 TP Management Parameters
If any TP properties have been changed, the button will be presented enabling itsuse. Only after clicking the button will the modifications be completed.
Click to send the TP information to a file or a printer.
Click to quit the window. All unsaved modifications will be lost.
Click to launch the online help.
10.5.2 TerminalPoint Mapping
To open TP mapping, select . The window will be shown. (See Fig. 10.10)
Fig. 10.10 TP Multiplexing Structure Query
Select the corresponding Card and Port. Then click to view the TP Mapping for theselected port. (See Fig. 10.11)
Fig. 10.11 TP Multiplexing Structure, View 1
-
7/27/2019 Tecnical Service 7020
71/203
Click the circle with a horizontal line to expand the tree, Click the circle with the vertical lineto collapse the tree. Use a right-click on the point and choose to open only thisbranch or to open all the branches including the sub-branches. (See Fig.10.12)
Fig. 10.12 TP Multiplexing Structure, View 2
The point color indicates its status: blue color indicates that this point is vacant and thebrown color indicates it is occupied.
If the TP is unused, it can be mapped by highlighting and right-clicking the point. (See Fig.10.13)
-
7/27/2019 Tecnical Service 7020
72/203
Fig. 10.13 Modify Mapping
After modifications of all the mappings are finished, click to confirm the modification.
To check the real-time mapping information, clicking the button at anytime.
Click to exit the window.
There is no tributary channel numbering present.
The displaying rule for KLM in LCT(based on timeslot) is compliant with ITU-T G.707standard.
LCT has supported sorting according to tributary (and it is the default displayed mode), andthere is KLM value. Operator can find the relationship between the timeslot number (TS#)and tributary number (Trib#) according to table listed below.
TU-3 TU-12 TS# Trib# TU-3 TU-12 TS# Trib# TU-3 TU-12 TS# Trib#
-
7/27/2019 Tecnical Service 7020
73/203
100
111
112
113
121
122
123
131
132
133
141
142
143
151
152
153
161
162163
171
172
173
1
22
43
64
4
25
46
67
7
28
49
70
10
31
52
73
13
34
55
76
16
3758
79
19
40
61
82
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1718
19
20
21
200 211
212
213
221
222
223
231
232
233
241
242
243
251
252
253
261
262263
271
272
273
2
23
44
65
5
26
47
68
8
29
50
71
11
32
53
74
14
35
56
77
17
3859
80
20
41
62
83
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
3839
40
41
42
300 311
312
313
321
322
323
331
332
333
341
342
343
351
352
353
361
362363
371
372
373
3
24
45
66
6
27
48
69
9
30
51
72
12
33
54
75
15
36
57
78
18
3960
81
21
42
63
84
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
5960
61
62
63
Tab. 10.5 Tributary(Trib#) to KLM to Timeslot(TS#) Numbers Mapping
10.6 SynchronizationManagementTNMS-M SURPASS hiT 7020 LCT supports multiple timing references. Each reference canbe configured as an STM-N, TimeIN1, and TimeIN2. Each of the references has 4 levels ofpriority.
Right-click the CC Card, and select , or
Select
A window, with the Timing Source of the NE will be shown.(See Fig. 10.14)
-
7/27/2019 Tecnical Service 7020
74/203
Fig. 10.14 Synchronization Management, Timing Source of NE
10.6.1 Global Settings
Click to open the global settings of the Timing Source Management. (SeeFig. 10.15)
Fig. 10.15 Global Settings
-
7/27/2019 Tecnical Service 7020
75/203
enables quality level available or not. Select in the drop-down menu.
When is selected in the drop-down menu, the menuwill be available. Choose , , , or SEC(0 0B)>from the drop-down menu.
Click to check the real-time status.
Click to accept modifications.
Click to quit the window without saving any modifications.
Click to launch the Online Help.
10.6.2
Configuringthe SystemClockTo configure the system clock, click . (See Fig. 10.14) The window will be shown. (See Fig. 10.16)
Fig. 10.16 System Clock, Switching Timing Sources
, , and show the current timing status and configuration.
The field indicates the current operation mode of this NE, including:
When Synchronization Supply Units and SDH equipment clocks cannotaccess stored data, or have never had a reference input, they use their own internal clocksto generate the synchronization signal until the network is restored.
-
7/27/2019 Tecnical Service 7020
76/203
When the quality of the synchronization inputs falls below accepted levels,Synchronization Supply Units and SDH equipment clocks first use stored data to controlphase and frequency variations.
The clock has its frequency phase locked to an input reference signal.Select one of the three options in the field, and then click tochange the mode. When is selected, modify the and settings if or in has been selected. Click to confirm the changes. If the state is , the optionwill be grayed out.
Click to quit the window.
Click to launch the online help.
10.6.3 Configuringthe Reference
Use the window (See Fig. 10.14) to configure the timereference.
Double-click the corresponding time reference, and a window will be shown. (See Fig. 10.17)
Fig. 10.17 Timing Source Reference Properties
In the window, the current status of the selectedtiming source is shown.
Check to keep the reference valid.
-
7/27/2019 Tecnical Service 7020
77/203
Check to monitor the reference.
Select the corresponding from 1 (the highest priority) to 12 (the lowest priority).
Select in the drop-down menu; options include or modes. In the mode, the QL cannot be changed, while in the mode, the QL can be set to a given value.
When setting the to , select the desired quality levelin the drop-down menu of . The QL levels include:
PRC (Primary Reference Clock): A reference frequency standard comprising an ensemble ofPRS that provide a reference frequency signal compliant with ITU G.811 or ETSI EN 300462-6-1. The free run accuracy of PRC must be 10-11.
SSU-A (Quality Level - SSU Transit): One of the SSM codes. This indicates that the clocksource is traceable to a transit node SSU and should be indicated using a '0100' code.
SSU-B (Quality Level - SSU Local): One of the SSM codes. This indicates that the clocksource is traceable to a local node SSU and should be indicated using a '1000' code.
SEC (Quality Level SEC): One of the SSM codes. This indicates that the clock source istraceable to an SEC and should be indicated using a '1011' code.
DNU (Quality Level - Do Not Use): One of the SSM codes.
-
7/27/2019 Tecnical Service 7020
78/203
11 Ethernet Configuration and Management
11.1 BridgeConfigurationTo configure Bridge Configuration:
Open Chassis View, right-click the corresponding Ethernet card and select in pop-up menu.
The window will be shown. (See Fig. 11.1)
Fig. 11.1 Bridge Properties
The section can display the current NE, Card name, and the status ofthe bridge in corresponding items. Click the drop-down menu of to selectone type of tag needed. Input a label to help identify this bridge.
Below this window, there are two tables, which list all LAN and WAN ports. Click the tab tochange the table between them. After selecting one port, double-click it to see more detailinformation about this port.
Click to check the latest information.
Click to confirm the modification without closing the window.
Click to confirm the modification if the user wants this window closed.
Click to quit the window. All unsaved changes will be lost.
-
7/27/2019 Tecnical Service 7020
79/203
Click to print the information of the bridges.
Click< Help> to launch the online help.
11.2 LAN Card Configurationand ManagementLAN card configuration and management is similar to SDH card configuration andmanagement.
To open the window, follow the steps below:
Select the corresponding Ethernet card.
To open the window without a specific port defined:
Right-click the card, and select .
To open the window with a specific port defined:
Select the corresponding port in the Ethernet card, right-click on it, and select .
The window will be shown. (See Fig. 11.2)
Fig. 11.2 LAN Port Configuration
-
7/27/2019 Tecnical Service 7020
80/203
11.2.1 LANPort Properties
Can be set as , , or .
Can be set as or . Can be set as or .
Choose to make the BRL available.
In the section, if is selected in the field, the other three parameters will be grayed out. If is selected,set these three parameters manually.
Click to check the latest information.
Click to confirm the modification without closing the window.
Click to confirm the modification and close the window.
Click to quit the window. All the unsaved changes will be lost.
Click to launch the online help.
11.2.2 VLANRate Limiting
In the window (See Fig. 11.3), in the section,choose and then click .
The window will be shown. (See Fig. 11.3)
Fig. 11.3 Rate Limit Config
The Rate Limit can be chosen from 64kbps to 2048kbps step by 64k. If mbps is used as theunit, the Rate Limit can be chosen from 2 mbps to 100 mbps step by 1mbps.
Click to confirm the modifications and continue adding VLAN Rate Limit.
Click to confirm the modifications and quit this window.
Click to quit this window. All the unsaved modifications will be lost.
Click to launch the online help.
11.2.3 CoS Configuration
In the window (See Fig. 11.2), click , a new window of will be shown. (See Fig. 11.4)
-
7/27/2019 Tecnical Service 7020
81/203
Fig. 11.4 Change Cos
There are four classes can be set, which are , , , and .Click to confirm the modifications.
Click to confirm the modifications and quit this window.
Click to quit this window. All the unsaved modifications will be lost.
Click to launch the online help.
11.3 WANPort ConfigurationTo configure WAN Ports, select the corresponding Ethernet card.
Right-click the card and select , the window will be shown. (See Fig. 11.5)
Fig. 11.5 WAN Port Configuration
-
7/27/2019 Tecnical Service 7020
82/203
Select the port to modify in the drop-down menu.
The settings of the and sections in this window are thesame as that in the window.
In , enable or disable LCAS and then click for detailed settings. (See Fig. 11.6)
Fig. 11.6 Bandwidth Configuration
For example, to set bandwidth to 4Mb, choose VC12-1 and VC12-2 (Other AUGs can bechosen from the left table) by clicking < >.
Click to confirm the modification without closing the window.
Click to confirm the modification with this window closed.
Click to quit the window. All the unsaved changes will be lost.
Click to launch the online help.
11.4 VLANManagement
-
7/27/2019 Tecnical Service 7020
83/203
Select the corresponding Ethernet card, right-click, and select . A newwindow of will be shown. (See Fig. 11.7)
In the section, fill in the conditions as needed.
Fig. 11.7 VLAN Management
Click , all VLANs based on the query conditions will show in the list.
Choose one VLAN record, by clicking , a new window will be shown whichwill enable the VLAN record to be modified. (See Fig. 11.8)
Click , to delete the VLAN selected.
Click to quit the window without saving any modifications.
Click to launch the online help.
-
7/27/2019 Tecnical Service 7020
84/203
Fig. 11.8 Modify VLAN Based on VLAN
Use the tab to reset VLAN ID and VLAN Name, and to select ports.
Click to set modifications in the window.
Click to confirm changes and quit the window.
Click to quit the window without saving any modifications.
Click to launch the online help.
Use the tab to modify the VLAN List. (See Fig. 11.9)
-
7/27/2019 Tecnical Service 7020
85/203
Fig. 11.9 Modify VLAN Based on Ports
Select the Port in the drop-down menu and enter the number in the field.
Click to set modifications in the window.
Click to confirm changes and quit the window.
Click to quit the window without saving any modifications.
Click to launch the online help.
11.5 Priority AlgorithmConfigurationSelect the corresponding Ethernet card, right-click, and select . A new window of will be shown. (See Fig. 11.10)
-
7/27/2019 Tecnical Service 7020
86/203
Fig. 11.10 Egress Priority Weight Config
Can be set as (weighted round robin) or (strict priority).
Set as and click to enter the window. (See Fig. 11.11)
-
7/27/2019 Tecnical Service 7020
87/203
Fig. 11.11 Output Priority Algorithm Configuration
Click to modify the Priority Weight in a new window.
Click to check the Priority Weight.Click to quit the window without saving any modifications.
Click to launch the online help.
For example, to modify one Priority Weight, choose it and click , the window will be shown. (See
Fig. 11.12) Fill in the Priority Weight desired and click .
-
7/27/2019 Tecnical Service 7020
88/203
Fig. 11.12 Modify Priority Weight
11.6 Static MACAddressConfiguration
To configure Static MAC Address, select the corresponding Ethernet card.Right-click and click .
The window will be shown. (See Fig. 11.13) The VLAN Idsand Ports of all the MAC Addresses will be listed in this window.
-
7/27/2019 Tecnical Service 7020
89/203
Fig. 11.13 Static MAC Address Configuration
Select the corresponding MAC; click to delete existing MAC.
To add a new MAC Address, click . An window will be shown.(See Fig. 11.14)
-
7/27/2019 Tecnical Service 7020
90/203
Fig. 11.14 Add MAC Address
Input the .
Input the and select the corresponding port in the drop-down menu.
Click to confirm the action and continue adding other MAC Address.
Click to confirm the action and close the window.
Click to quit the window, all unsaved modifications will be lost.
Click to launch the online help.
11.7 ACL ConfigurationACL (Access Control List) is used to manage MAC addresses.
Select the corresponding Ethernet card, right-click, and select . A newwindow of will be shown. (See Fig. 11.15)
-
7/27/2019 Tecnical Service 7020
91/203
Fig. 11.15 ACL Config
Click , a new window will be shown and new ACL may be added in it. (See Fig. 11.16)
Click , the chosen ACL will immediately be deleted.
Click to quit the window without saving any modifications.
Click to launch the online help.
Fig. 11.16 Add ACL
11.8 GroupBroadcastConfigurationTo configure Group Broadcast, select the corresponding Ethernet card, right-click it, andselect .
The window will be shown. All MAC Addresses and Port Settingswill be listed in this window. (See Fig. 11.17)
-
7/27/2019 Tecnical Service 7020
92/203
Fig. 11.17 Group Broadcast Configuration
To delete a MAC Address, select the corresponding MAC and click .
To add a new MAC Address, click . A new window will beshown. (See Fig. 11.18)
-
7/27/2019 Tecnical Service 7020
93/203
Fig. 11.18 Add MAC Address
Input the MAC Address.
Select the port in the panel, and click the ==> button, to add it to the panel.
Click to confirm the action and continue adding other MAC Addresses.
Click to confirm the action and close the window.
Click to quit the window. All the unsaved modifications will be lost.
Click to launch the online help.
11.9 RSTPConfigurationSelect the corresponding Ethernet card, right-click, and select . A newwindow, , will be shown. (See Fig. 11.19)
-
7/27/2019 Tecnical Service 7020
94/203
Fig. 11.19 RSTP Properties Configuration
In the window, modify the Max Age, Switch Priority, Forward Delay, and Hello Time options.Click to check the real-time port RSTP properties.
Click to set modifications in the window.
Click to confirm changes and quit the window.
Click to quit the window without saving any modifications.
Click to print the information of RSTP Properties.
Click to launch the online help.
Double-click a row to view the port RSTP properties. (See Fig. 11.20)
-
7/27/2019 Tecnical Service 7020
95/203
Fig. 11.20 Port RSTP Configuration
In the window, modify Port Priority, Path Cost, and Disable or Enable Port.
-
7/27/2019 Tecnical Service 7020
96/203
12 Protection ManagementSURPASS hiT 7020 supports SNCP and MSP management.
12.1 SNCPManagementTo open the window, select from the main menu.
A new window will be shown. (See Fig. 12.1)
Fig. 12.1 SNCP Management
12.1.1 Viewingand ModifyingSNCP
The section in the window allows setting the conditionsof querying to searching SNCP database. The querying conditions include , ,, , and . Type in the Label of the SNCP to be searched; for theother parameters (Capacity, Card, Direction, and Port), use the drop-down menus providedto set parameters. Click to start searching the database. The results will bedisplayed as shown in the table below.
The SNCPs and their properties will be displayed in the table.
Double-click an SNCP or select one SNCP then click to view and modify it.(See Fig. 12.2)
-
7/27/2019 Tecnical Service 7020
97/203
Fig. 12.2 SNCP Properties
The SNCP Properties supported are listed in Tab. 12.1.Items Description
Capacity The transmission capacity. It cannot be modified in the View/Modify
windowDirection The transmission direction. It cannot be modified in the View/Modify
window.Restore Mode The restore mode of this protection plan which includes Revertive
and No Revertive.Wait To Restore Time The time interval waited for restore. This number must be between
60 and 720.Label A label chosen by the user to help the user remember SNCPs
convenientlyHold off Time The time to hold off. This time must be between 0 and 100.Tab. 12.1 SNCP Properties
denotes the SNCP source/destination TP.
-
7/27/2019 Tecnical Service 7020
98/203
Select the current working TP, including its working card, port, and TP. Thiscannot be modified in the View/Modify window.
Select the protection TP, including its protecting card, port, and TP. This
cannot be modified in View/Modify window.Click to submit the modifications.
Click CC to create a new CC. (See Fig. 12.3)
Click to quit window. All the unsaved modifications will be lost.
Click to launch the online help.
Fig. 12.3 Create Cross-Connect
12.1.2 CreatingSNCP
In the window click to create a new SNCP. (See
Fig. 12.4)
-
7/27/2019 Tecnical Service 7020
99/203
Fig. 12.4 Create SNCP
12.1.3 DeletingSNCP
In the window click to delete the selected SNCP. (See Fig.12.5)
-
7/27/2019 Tecnical Service 7020
100/203
Fig. 12.5 Delete SNCP
12.1.4 SwitchingSNCP
Click in the window to switch SNCP. The window will be shown (See Fig. 12.6)
Fig. 12.6 SNCP Switch
Select a command in : Clear, LockOut, Force Switch to Protection, ForceSwitch to Working, Manual Switch to Protection, and Manual Switch to Working.
Click to check the latest information.
-
7/27/2019 Tecnical Service 7020
101/203
Click to start switch.
Click to quit the window. All unsaved modifications will be lost.
12.2 MSPManagementTo open the window:
From the main menu, select .
A new window will be shown. (See Fig. 12.7)
Fig. 12.7 MSP Management
Input conditions in the text boxes, including: and . Select options in thedrop-down menus, including: , , and . Click to query the MS protection.
Click to query the MS protection.
Click to check the result. (See Fig. 12.8)
Click to quit the window. All the unsaved modifications will be lost.
Click to launch the online help.
-
7/27/2019 Tecnical Service 7020
102/203
Fig. 12.8 MSP Property
The window includes the following properties: ,, , , , ,, , , and .
In the window, select one MSP, and click to start theoperation. The window will be shown. (See Fig. 12.9)
-
7/27/2019 Tecnical Service 7020
103/203
Fig. 12.9 External Commands
The section includes: , , , , , and .
In the drop-down menu, select one command and click to operatethis command. This window will not be closed.
Click to check the latest information.
Click to operate this command and quit the window.
Click to quit the window. All the unsaved modifications will be lost.
Click to launch the online help.
In the window, click to create a new protection. A window will be shown. (See Fig. 12.10)
-
7/27/2019 Tecnical Service 7020
104/203
Fig. 12.10 Create Linear Multiplex Section Protection Group
Input and in the corresponding fields andselect the options in the drop-down menus.
Click to create MS Protection and close this window.
Click to quit the window. All the unsaved modifications will be lost.
Click to launch the online help.
In the window,
Click to delete the selected protection.
Click to print the information of the selected protection.
Click to launch the online help.
-
7/27/2019 Tecnical Service 7020
105/203
13 Routing and Protocol Configuration
13.1 IP Route Configuration
13.1.1 IP Interface
Select and the window will be shown. (See Fig. 13.1)
The IP Interface parameters about the NE will be list in the table. Meantime,every parameter is list below.
Fig. 13.1 IP Interface
All parameters and their meaning are list as below:
: A unique number (greater than zero) that identifies each interface for SNMPidentification of that interface.
: a brief description of the IP Interface
: the type of the IP Interface
: the maximum long of frame
: the speed of the IP Interface
: the physical address of the IP Interface
: the IP interfaces administrative status. The value formed on the interface,
and the interface will be advertised as an internal route to some area.: the IP interfaces operation status.
-
7/27/2019 Tecnical Service 7020
106/203
Click to check the latest information.
Click to close this window.
Click to launch the online help.
13.1.2 IP Static Route
Select and the window will be shown. (See Fig. 13.2)
The IP static routes parameters about the NE will be list in the table.Meantime, every parameter is list below.
Fig. 13.2 IP Static Route
All parameters and their meaning are list as below:
: the destination IP address
: IP mask of the IP static routes
: the protocol of the IP static routes
: A unique number (greater than zero) that identifies each interface for SNMPidentification of that interface.
: the NextHop of the IP static routes
: the administrative status of the IP static routes. The value formed on theinterface, and the interface will be advertised as an internal route to some area.
: the operation status of the IP static routes.
: the metric type of the IP static routes: the cost of the IP static routes
-
7/27/2019 Tecnical Service 7020
107/203
Click to check the latest information.
Click to close this window.
Click to launch the online help.
Choose an IP static route in the table, and click to edit the selected IP static route.(See Fig. 13.3)
Fig. 13.3 Edit IP Static Route
Click to confirm the modifications.
Click to close the window without saving the modifications.
Click in the window to add a new IP static route. (See Fig. 13.4)
-
7/27/2019 Tecnical Service 7020
108/203
Fig. 13.4 Add IP Static Route
Click to confirm the modifications.
Click to close the window without saving the modifications.
13.1.3 IP RoutingTableSelect and the window will be shown. (See Fig. 13.5)
The IP routing table parameters about the NE will be list in the .Meantime, every parameter is list below.
-
7/27/2019 Tecnical Service 7020
109/203
Fig. 13.5 IP Routing Table
All parameters and their meaning are list as below:
: the destination IP routing tabl
: IP mask of the IP routing table
: the protocol of the IP routing table
: A unique number (greater than zero) that identifies each interface for SNMPidentification of that interface.
: the NextHop of the IP routing table
: the type of the IP routing table
: the age of the link state advertisement in seconds.
: the metrics of the IP routing table
Click to check t