TECHNICAL INFORMATION INSTALLATION BUNDLES: SIZES AND … · 2019-05-17 · SPER CB CVJ Ed.04.2019...

2
JOSPER S.A.U. Gutenberg, 11 08397 Pineda de Mar - Barcelona - Spain T +34 93 767 15 16 [email protected] www.josper.es JOSPER COMBO CVJ Ed.04.2019 - Josper reserves the right to make modifications to catalogues, pricelists and promotional material according to the development and improvements applied to its equipment. ACCESSORIES INCLUDED Firebreak · Firebreak hat · Grill racks · 2 Tongs · Poker for coal CVJ-050-2-HJX-45 x2 mm in [ ] x2 500 19 3/4 510 20 1/8 760 30 510 20 1/8 Total fire up time 35 min average Charcoal daily consumption 32 to 36 kg 70.5 to 79.4 lb Broiling temperature 250 to 350 ºC 482 to 662 ºF Nominal heat output 12 kW 16 hp Net weight - - TECHNICAL INFORMATION Sizes bundle - - Gross weight bundle - - BUNDLES: SIZES AND WEIGHTS INSTALLATION Clearance with non-flammable equipment 100 mm 4 in Clearance with flammable equipment 300 mm 12 in Exhaust rate 7000 m 3 /h 4120 cfm

Transcript of TECHNICAL INFORMATION INSTALLATION BUNDLES: SIZES AND … · 2019-05-17 · SPER CB CVJ Ed.04.2019...

Page 1: TECHNICAL INFORMATION INSTALLATION BUNDLES: SIZES AND … · 2019-05-17 · SPER CB CVJ Ed.04.2019 - Josper reserves the right to make modi cations to catalogues, pricelists and promotional

JOSPER S.A.U. Gutenberg, 11 08397 Pineda de Mar - Barcelona - SpainT +34 93 767 15 [email protected]

JOSPER COMBO CVJ

Ed.04.2019 - Josper reserves the right to make modifications to catalogues, pricelists and promotional material according to the development and improvements applied to its equipment.

ACCESSORIES INCLUDED

Firebreak · Firebreak hat · Grill racks · 2 Tongs · Poker for coal

CVJ-050-2-HJX-45

x2 mmin[ ]x2

50019 3/4

510

20 1

/8

76030

510

20 1

/8

Total fire up time 35 min average

Charcoal daily consumption 32 to 36 kg 70.5 to 79.4 lb

Broiling temperature 250 to 350 ºC 482 to 662 ºF

Nominal heat output 12 kW 16 hp

Net weight - -

TECHNICAL INFORMATION

Sizes bundle - -

Gross weight bundle - -

BUNDLES: SIZES AND WEIGHTS

INSTALLATION

Clearance with non-flammable equipment 100 mm 4 in

Clearance with flammable equipment 300 mm 12 in

Exhaust rate 7000 m3/h 4120 cfm

Page 2: TECHNICAL INFORMATION INSTALLATION BUNDLES: SIZES AND … · 2019-05-17 · SPER CB CVJ Ed.04.2019 - Josper reserves the right to make modi cations to catalogues, pricelists and promotional

JOSPER S.A.U. Gutenberg, 11 08397 Pineda de Mar - Barcelona -SpainT +34 93 767 15 [email protected]

JOSPER COMBO CVJ

900 [35 1/2]

2360 [92 1/2]

1320 [52]

1300

[51

1/4]

1790

[70

1/2]3

* * *

2800 [110 1/4]

1 1500[59 1/8]

1

2000

[78

3/4]1

575[22 5/8]

1

1200[47 1/4]

2

1025 [40 3/8]

Braising area 760 x 510 mm 30 x 20 1/8 in

Recommended for ± 120 diners

Fire up time 35 min average

Charcoal daily consumption 12 to 16 kg 26.5 to 35 lb

Performance 9h

Production per hour 90 kg average 192 lb average

Grill rack capacity in GN trays 2xGN1/1

Nominal heat output 7,4 kW 9.92 hp

Flue gas mass flow 15,39 g/s 0.54 oz/s

HJX-45 TECHNICAL INFORMATION

Braising area 500 x 510 mm (x2) 19 3/4 x 20 1/8 in (x2)

Grill stroke 290 mm 11 1/2 in

Fire up time 20 min average

Charcoal daily consumption 20 to 22 kg 44 to 48.5 lb

Nominal heat output 4,5 kW 6 hp

PVJ-050-2 TECHNICAL INFORMATION

MINIMUM DISTANCE TO FLAMMABLE ELEMENTS: 300 mm [12 in] / RECOMMENDED DISTANCE TO ANOTHER ELEMENTS: 100 mm [4 in] RECOMMENDED HOOD’S MINIMUM DIMENSIONS

RECOMMENDED CHEF’S WORKING SPACE

THIS DISTANCE MAY BE MODIFIED BY THE SMOKE OUTLET SET CONFIGURATION.

*1

2

3mmin[ ]