Technical Data TECHNICAL DATA - VIVA Railings
Transcript of Technical Data TECHNICAL DATA - VIVA Railings
iRAIL™ADDITIONAL OPTIONS
A handrail and a light fixture, raising the bar for minimalistic design by combining
these two essential building elements into one. VIVA’s iRail™ is engineered with high
performance and long lasting LED’s. Available in a cool and warm white colors, light
intensities and housing profiles, this ADA compliant rail can be used for interior and exterior
applications.
PRODUCT: iRAIL™ | INFILL: PICKET PANELGRANDSCAPE BOARDWALKTHE COLONY, TEXAS
Visit vivarailings.com/irail for product data, specifications and drawings.
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com1
iRAIL™
Technical Data
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 1 of 5ILLUMINATED RAILING SYSTEM
Specifications
TOP RAIL / HAND RAIL FINISH SPEC
iRAIL LINEAR ¹(CONTINUOUS iRAIL)
Ø1-1/2" Stainless Steel (304 or 316) #6 Satin
Color:Output:Beam Angle:Orientation:Power:Lens:CRI:Rating:
3000K Warm White or 4000K Cool White ³Medium: 3 Watt/ft – 185 lumens/ft. or High: 5 Watt/ft – 250 lumens/ft.120°Symmetrical or Asymmetrical at 30°Input 120 - 277 V AC, Output 12 V DCClear or Frosted>90IP67
Ø2" Wood (Red Oak, White Oak, Cherryor Maple) ² Unstained
iRAIL PODS
Ø1-1/2" Stainless Steel (304 or 316)
#6 Satin
Color:Output:Beam Angle:Orientation:Power:CRI:Rating:
3000K Warm White or 4000K Cool White1.5 Watt - 90 lumens for sym., 76 lumens for Asym. per pod60°Symmetrical or Asymmetrical at 22°Input 120 - 277 V AC, Output 24 V DC>80IP67
Ø2" Stainless Steel (304 or 316)
(1) All iRAIL LINEAR products are ETL certified; ETL mark is proof of product complianceto North American safety standard.
(2) Other species available upon request.
(3) 2700K Warm Whiteand 3500K Natural White available upon request.US
Intertek
CM
LISTED
TECHNICAL DATA
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com2
IR AIL
iRAIL™ RAILING SYSTEM - SPECIFICATIONS
iRAIL™VIVA RAILINGS, LLC
1454 HALSEY WAY, CARROLLTON, TX 75007P: 972-353-8482 F: 972-353-0013
e: [email protected] www.vivarailings.com
V
VA
TM
I Page 2 of 5ILLUMINATED RAILING SYSTEM
Illuminated Railing
+
ELECTRICAL CONDUIT MINIMUM 12"ABOVE FINISH FLOOR(BY OTHERS)
iRAIL WIRE FEED14 AWG WIRE, 35'-0" MAX. LENGTH(BY OTHERS)
-
POWER SUPPLY 12VDC
MIN. 20' CABLE TO BECONNECTED TO iRAIL
(BY OTHERS)
PROVIDE ONE PAIR OF WIRES 14 GA (BLACK-RED) FOR EVERY iRAIL RUN. EVERY iRAIL RUNCOVERS:· 32ft MAX FOR iRAIL LINEAR MEDIUM INTENSITY (3 W/ft)· OR 16ft MAX FOR iRAIL LINEAR HIGH INTENSITY (5 W/ft)· OR 32ft MAX FOR iRAIL POD
F.F.
VIVA RAIL TERMINATIONTO FLOOR OR WALL
DRIVERFURNISHED BY VIVAINSTALLED CONCEALED BYLICENSED ELECTRICIAN
iRAIL POD ORIENTATIONOPTIONS
18" 24"
OR 36"
iRAIL POD SPACINGOPTIONS
POD
iRAIL Linear
30° ASYM.LINEAR
SYM.LINEAR
iRAIL LINEAR ORIENTATIONOPTIONS
22° ASYM.POD
SYM. POD
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com3
IR AIL
iRAIL™ ILLUMINATED RAILING SYSTEM
iRAIL™ MOUNTING CONDITION-FEED FROM WALL IR AIL
Illuminated WallRailDetail# IR-W01
Mounting Condition, Feed from Wall
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 3.1 of 5ILLUMINATED RAILING SYSTEM
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVARAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
WALL
DRIVER
iRAIL
DRIVER
iRAIL
WALL
DRIVER
iRAIL
Illuminated Handrail orTop Rail
Detail# IR-W02
Illuminated FSRDetail# IR-W03
Illuminated Shoe HandrailDetail# IR-W04
DRIVER
iRAIL
36" T
O F
F
FINISH FLOOR
3'-0
"
FINISH FLOOR
3'-0
"
FINISH FLOOR
3'-0
"
WALL WALL
*WALL OR FLOOR WIRE FEED ENTRY REQUIRED AT RAILING TERMINAL POINT. TYP.
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com4
IR AIL
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com5
iRAIL™ MOUNTING CONDITION-FEED FROM FLOOR
Mounting Condition, Feed from Floor
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 3.2 of 5ILLUMINATED RAILING SYSTEM
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVARAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
WALL
3'-0
"
Illuminated Handrail orTop Rail
Detail# IR-W02
Illuminated FSRDetail# IR-W03
Illuminated Shoe HandrailDetail# IR-W04
WALL WALL
DRIVER DRIVER DRIVER
FINISH FLOOR FINISH FLOOR FINISH FLOOR
3'-0
"
3'-0
"
iRAIL
iRAIL iRAIL
*WALL OR FLOOR WIRE FEED ENTRY REQUIRED AT RAILING TERMINAL POINTTYP.
IR AIL
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com6
iRAIL™ LIGHT DISPERSION
0 1' 2' 3' 4' 5'1'2'3'4'5'
(Y)42"
36"
(X)
iRAIL LINEAR LIGHT DISPERSION DIAGRAM
All Values in Foot-Candle (FC) +/-15%, Values using clear lens.
Y
XLIGHTCOLOR
INTENSITY(OUTPUT) POWER 0' 1' 2' 3' 4' 5'
3000 K
MEDIUM185 lumens/ft 3 W/ft
36" 44.1 30.3 15.6 7.7 4.1 2.342" 38.3 28.7 16.2 8.3 4.9 2.8
HIGH250 lumens/ft 5 W/ft
36" 59.5 41.2 20.8 10.3 5.5 3.042" 52.3 39.3 21.9 11.4 6.6 3.8
4000 K
MEDIUM185 lumens/ft 3 W/ft
36" 44.5 31.6 15.2 7.2 3.8 2.242" 38.7 29.6 16 8.3 4.5 2.7
HIGH250 lumens/ft 5 W/ft
36" 61.7 43.9 21.6 10.5 5.3 3.142" 54.3 42.2 22.6 12 6.4 3.7
iRAIL LINEAR Dispersion Diagram
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 4.1 of 5ILLUMINATED RAILING SYSTEM
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVARAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
iRAIL LINEAR
IR AIL
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com7
iRAIL™ iRAIL POD ISO FOOT CANDLE DISPERSION DIAGRAM
> 16 ft.cl
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl> 1 ft.cl
POD
1'-0"
> 16 ft.cl
> 8 ft.cl
> 4 ft.cl> 2 ft.cl> 1 ft.cl
POD
1'-0"
ISO FOOT CANDLE DISPERSION PLAN VIEW, h (iRAIL HEIGHT)= 3'-0", ASYM. w/ 1'-6" POD SPACINGFC: MAX= 16.0, MIN= 0.1, AVE.= 5.1
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl> 1 ft.cl
POD
POD
1'-0"
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl> 1 ft.cl
ISO FOOT CANDLE DISPERSION PLAN VIEW, h (iRAIL HEIGHT)= 3'-6", ASYM. w/ 1'-6" POD SPACINGFC: MAX= 13.5, MIN= 0.1, AVE.= 5.0
POD
1'-0"
iRAIL Pod Iso Foot Candle Dispersion Diagram
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 4.2 of 5ILLUMINATED RAILING SYSTEM
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVARAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
h
6'-0"18"
PLAN VIEW, h=36", PS=18", SYMMETRIC PODSFC: MAX=19.8, MIN=0.2, AVE.=6.1
PLAN VIEW, h=36", PS=18", ASYMMETRIC PODSFC: MAX=16.0, MIN=0.1, AVE.=5.1
PLAN VIEW, h=42", PS=18", SYMMETRIC PODSFC: MAX=16.9, MIN=0.3, AVE.=6.0
PLAN VIEW, h=42", PS=18", ASYMMETRIC PODSFC: MAX=13.5, MIN=0.1, AVE.=5.0
h: Illuminated Rail HeightPS: Pod Spacing
18"
18"18"
PS
IR AIL
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com8
iRAIL™
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl> 1 ft.cl
POD
1'-0"
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl> 1 ft.cl
POD
1'-0"
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl> 1 ft.cl
ISO FOOT CANDLE DISPERSION PLAN VIEW, h (iRAIL HEIGHT)= 3'-6", ASYM. w/ 2'-0" POD SPACINGFC: MAX= 10.1, MIN= 0.1, AVE.= 3.7
PODPOD
1'-0"
ISO FOOT CANDLE DISPERSION PLAN VIEW, h (iRAIL HEIGHT)= 3'-0", ASYM. w/ 2'-0" POD SPACINGFC: MAX= 11.9, MIN= 0.1, AVE.= 3.8
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl
> 1 ft.cl
POD
POD POD
1'-0"
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 4.3 of 5ILLUMINATED RAILING SYSTEM
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVARAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
h
6'-0"24"
PLAN VIEW, h=36", PS=24", SYMMETRIC PODSFC: MAX=14.9, MIN=0.1, AVE.=4.6
PLAN VIEW, h=36", PS=24", ASYMMETRIC PODSFC: MAX=11.9, MIN=0.1, AVE.=3.8
PLAN VIEW, h=42", PS=24", SYMMETRIC PODSFC: MAX=12.7, MIN=0.2, AVE.=4.5
PLAN VIEW, h=42", PS=24", ASYMMETRIC PODSFC: MAX=10.1, MIN=0.1, AVE.=3.7
h: Illuminated Rail HeightPS: Pod Spacing
24"
24" 24"
PS
iRAIL Pod Iso Foot Candle Dispersion Diagram
iRAIL POD ISO FOOT CANDLE DISPERSION DIAGRAM
IR AIL
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com9
iRAIL™
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl
> 1 ft.cl
POD
1'-0"
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl> 1 ft.cl
POD
1'-0"
> 4 ft.cl
> 2 ft.cl
> 1 ft.cl
ISO FOOT CANDLE DISPERSION PLAN VIEW, h (iRAIL HEIGHT)= 3'-6", ASYM. w/ 3'-0" POD SPACINGFC: MAX= 6.8, MIN= 0.1, AVE.= 2.5
POD
1'-0"
ISO FOOT CANDLE DISPERSION PLAN VIEW, h (iRAIL HEIGHT)= 3'-0", ASYM. w/ 3'-0" POD SPACINGFC: MAX= 8.9, MIN= 0.0, AVE.= 2.5
> 8 ft.cl
> 4 ft.cl
> 2 ft.cl
> 1 ft.cl
POD
POD
1'-0"
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 4.4 of 5ILLUMINATED RAILING SYSTEM
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVARAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
PLAN VIEW, h=36", PS=36", SYMMETRIC PODSFC: MAX=10.9, MIN=0.1, AVE.=3.0
PLAN VIEW, h=36", PS=36", ASYMMETRIC PODSFC: MAX=8.9, MIN=0.0, AVE.=2.5
PLAN VIEW, h=42", PS=36", SYMMETRIC PODSFC: MAX=8.6, MIN=0.1, AVE.=3.0
PLAN VIEW, h=42", PS=36", ASYMMETRIC PODSFC: MAX=6.8, MIN=0.1, AVE.=2.5
h: Illuminated Rail HeightPS: Pod Spacing
PS
h
6'-0"36" 36"
36" 36"
iRAIL Pod Iso Foot Candle Dispersion Diagram
iRAIL POD ISO FOOT CANDLE DISPERSION DIAGRAM
IR AIL
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com10
iRAIL™ iRAIL ORDER CODE
iRail Order Code
VIVA RAILINGS, LLC1454 HALSEY WAY, CARROLLTON, TX 75007
P: 972-353-8482 F: 972-353-0013e: [email protected] www.vivarailings.com
V
VA
TM
I Page 5 of 5ILLUMINATED RAILING SYSTEM
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVARAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN.REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
IR-LIN-1.5-304-30K-M-CL-0°
Available Applications: Ø1-1/2" E-Tube 1.5 Ø2" Wood 2W
iRAIL Linear LIN
Lens type, Clear CL Frosted FR
Intensity, Medium M High H
Orientation, Symmetric 0° Asymmetric 30°
Light color: Warm white 2700k 27K Warm white 3000k 30K Natural white 3500k 35K Cool white 4000k 40K
Railing Material: Stainless Steel 304 304 Stainless Steel 316 316 Red Oak ROK White Oak WOK Maple MPL Cherry CHR
iRAIL LINEAR ORDER CODE:
IR-POD-1.5-304-30K-0°
Available Applications: Ø1-1/2" Tube 1.5 Ø2" Tube 2
iRAIL Pod POD
Orientation, Symmetric 0° Asymmetric 22°
Light color: Warm white 3000k 30K Cool whit 4000k 40K
Alloy Composition: Stainless Steel 304 304 Stainless Steel 316 316
iRAIL POD ORDER CODE:
PRODUCT: IRAIL™
GRANDSCAPE BOARDWALKTHE COLONY, TX
What could be more beautiful than a Texas sunset along a half a mile boardwalk that lights the entirety of the walkway using subtle LED's hidden directly within the railing? The brand new Grandscape Boardwalk features over 2,000 linear feet of our CIRCA™ Picket Railing System and iRAIL Illuminated Railing. This is just the first stage of the ever expanding Grandscape Boardwalk by LMG Ventures.
Project Details: Location: The Colony, TXGeneral Contractor: LMG Ventures Architect: O'Brien ArchitectsFinish: #6 Satin Stainless Steel Project Scope: 824 Linear Feet of RailingsInfill: Picket Panels & iRAIL LED RailingDesign & Installation Hours: 199
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com11
IR AIL
PRODUCT: IRAIL™
UNIVERSITY OF TEXAS - AUSTIN MOODY COLLEGE SKY BRIDGEAUSTIN, TX
The University of Texas at Austin Moody College of Communication coincides with the School of Journalism and late night projects forced students to walk across the busy streets after hours. The recent addition of the Moody Bridge connecting the two via VIVA’s iRAIL™ illuminated railing, the sky bridge provides students a lighted, safe way between buildings. The CIRCA™ Cable System chosen alongside the iRAIL™ is a perfect complement to the cylindrical structure of the sky bridge.
Project Details: Location: Austin, TXGeneral Contractor: Flintco, LLC - AustinArchitect: Lawrence GroupFinish: #6 Satin Stainless SteelLED Illuminated iRail 4000K High OutputProject Scope: 600 Linear Feet of RailingsInfill: 3/16” Stainless Steel CableDesign & Installation Hours: 820
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com12
IR AIL
PRODUCT: IRAIL™
BB&T LEADERSHIP CONFERENCE CENTERGREENSBORO, NC
Nearly 12 acres and 58,000 sq. ft. of beautiful landscape surrounding the new BB&T Conference Center in North Carolina. Featuring a five-day leadership course and several other group programs, the BB&T Leadership Conference Center is a truly unique experience. Walking between the eight state-of-the-art buildings in the forest canopy, our iRAIL™ LED Illuminated Railing light the way late at night without having bright spotlights scatted throughout the landscape..
Project Details: Location: Greensboro, NCGeneral Contractor: Blum ConstructionArchitect: CJMW Architecture, Inc.Finish: Matte Black Powder CoatLED Illuminated iRail 3000K High OutputProject Scope: 1,809 Linear Feet of RailingsInfill: 3/16” Stainless Steel CableDesign & Installation Hours: 621
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com13
IR AIL
PRODUCT: IRAIL™
ROSS PEROT OFFICES / THE KATY TRAILDALLAS, TX
For the first time in decades, all generations of Perot family reside in one location. Historical Photos adorn the hallways that tell the story of the rich heritage of the Perot family. Their brand new offices features our CUBE™ Cable Railing and iRAIL™ LED which provides a private walkway to the Katy Trail behind the campus. The front entrance features our FSR™ iRAIL™ along the entirety of the stairs and the CUBE™ Cable follows along to the parking garage below.
Project Details: Location: Dallas, TXGeneral Contractor: Balfour Beatty ContractorsArchitect: Mithun INCFINISH: #6 Satin Stainless SteelLED Illuminated iRAIL Infill: 3/16" Cable Design & Installation Hours: 750
DESIGN + ENGINEER + FABRICATE + INSTALL vivarailings.com14
IR AIL