TECHNICAL DATA SHEET HIGH HEAD FLOW-MATE SERIESs3.supplyhouse.com/product_files/Zoeller - 263-0002 -...
Transcript of TECHNICAL DATA SHEET HIGH HEAD FLOW-MATE SERIESs3.supplyhouse.com/product_files/Zoeller - 263-0002 -...
© Copyright 2014 Zoeller Co. All rights reserved.502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | www.zoeller.com
FM27850414
Supersedes0114
TECHNICAL DATA SHEETHIGH HEAD FLOW-MATE SERIES
Models 161/4161, 163/4163, 165/4165 Effluent Pumps
SK1413
SINGLE SEAL
DOUBLE SEAL
19 5/16" [491 mm]
6" [152 mm]
4" 8 3/4"
6 1/2"
4" [102 mm]
6 11/32" [161 mm]
1 1/2" NPT STANDARD2" NPTOR3" NPTAVAILABLE
[222 mm]
[165 mm]
[102 mm]
6” (152 mm)
21 3/16” (538 mm)
4”(102 mm)
8 3/4”(222 mm)
6 1/2”(165 mm)
1 1/2" NPT STANDARD2” NPT or3” NPT Available
4” (102 mm)
4” (102 mm)
SK374
PRODUCT SPECIFICATIONS
NOTE: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with nonautomatic pumps.
MO
TOR
Horse Power 1/2 (161/4161, 163/4163) or 1 (165/4165)
Voltage 115 - 575
Phase 1 or 3 Ph
Hertz 60 Hz
RPM 3450
Type Permanent split capacitor or 3 Ph
Insulation Class B
Amps 2.4 - 15.5
PU
MP
Operation Automatic or nonautomatic
Auto On/Off Points 15-3/4" (400 mm) / 5-1/4" (133 mm)
Discharge Size 1-1/2" NPT (optional 2" or 3" flange)
Solids Handling 3/4" (19 mm) spherical solids
Cord Length 20' (6 m) standard
Cord Type1 Ph: UL listed 3-wire neoprene cord and plug or 3 Ph: 4-wire with no plug
Max. Head 86.5' (26 m)
Max. Flow Rate 100 GPM (379 LPM)
Max. Operating Temp. 130° F (54° C)
Cooling Oil filled
Motor Protection Auto reset thermal overload (1 Ph)
MA
TE
RIA
LS
Upper Bearing Ball bearing
Lower Bearing Ball bearing
Mechanical Seals Carbon and ceramic
Impeller Type Non-clogging vortex
Impeller Bronze
Hardware Stainless steel
Motor Shaft SAE 1117 carbon steel or 416 stainless steel
Gasket Neoprene square ring and gasket
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
®
Your Peace of Mind is Our Top Priority ®
Tested to Standard UL778 andCertified to CSA
Standard C22.2 No. 108
R
R LU
NOTE: See model comparison chart for specific details.
All Class 30 cast iron construction.
© Copyright 2014 Zoeller Co. All rights reserved.502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | www.zoeller.com
SELECTION GUIDE1. Integral float operated mechanical switch, no external control required.
2. For automatic use single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477.
3. See FM1228 for correct model of simplex control panel.
4. See FM0712 for correct model of duplex control panel.
5. Variable level control switch 10-0743 used as a control activator, specify simplex (3) float or duplex (4) float system. Refer to FM0526.
009920
PUMP PERFORMANCE CURVEMODELS 161/4161-163/4163-165/4165
GALLONSLITERS 0 80
FLOW PER MINUTE160 240 320
165/4165
TOTA
L DY
NAM
IC H
EAD
12
20
30
10
0
4
8
10 20 30
80
70
60
50
40
16
20
24
163/4163
40 50 60 70
161/4161
80 90 110
90
FEET
MET
ERS
100
400
NOTE: No UL listing for 200/208 1 Phase pumps, model 186 & 191, or double seal series.
MODELS 161/4161 165/4165163/4163Feet LitersGal.LitersGal.LitersGal.Meters
24.480Shut-off Head:
--56 ft. (17m)
--
50
7060
4030
152025
510
----
15.2
21.318.3
9.112.2
7620----
4562
170233
100
4.66.17.6
3.01.5
322857970
297265
93 352379
381086.5 ft. (26m)
--66 ft. (20m)
----
57
172206
12533
--15
4655
50
2339
5558
231231
223227
216
605957
6161
616059
6161
189
87148
208220
231227223
231231
ModelMODEL COMPARISON CERTIFICATIONS
Seal Mode Volts Ph Amps HP Hz Lbs Kg Simplex Duplex CSA UL
M161 Single Auto 115 1 15.5 1/2 60 80 36 1 --- Y Y
N161 / N4161 Single / Double Non 115 1 15.0 1/2 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y N(1)
D161 Single Auto 230 1 7.5 1/2 60 80 36 1 --- Y Y
E161 / E4161 Single / Double Non 230 1 7.5 1/2 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y Y
* H161 Single Auto 200 1 8.8 1/2 60 80 36 1 --- Y N
* I161 / I4161 Single / Double Non 200 1 8.8 1/2 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y N
* J161 / J4161 Single / Double Non 200 3 6.4 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* F161 / F4161 Single / Double Non 230 3 5.2 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* G161 / G4161 Single / Double Non 460 3 2.9 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* BA161/BA4161 Single / Double Non 575 3 2.4 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y N
M163 Single Auto 115 1 15.0 1/2 60 80 36 1 --- Y Y
N163 / N4163 Single / Double Non 115 1 15.0 1/2 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y N(1)
D163 Single Auto 230 1 7.5 1/2 60 80 36 1 --- Y Y
E163 / E4163 Single / Double Non 230 1 7.5 1/2 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y Y
* H163 Single Auto 200 1 8.5 1/2 60 80 36 1 --- Y N
* I163 / I4163 Single / Double Non 200 1 8.5 1/2 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y N
* J163 / J4163 Single / Double Non 200 3 6.0 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* F163 / F4163 Single / Double Non 230 3 4.8 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* G163 / G4163 Single / Double Non 460 3 2.9 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* BA163/BA4163 Single / Double Non 575 3 2.4 1/2 60 80 / 87 36 / 39 3 & 5 4 & 5 Y N
D165 Single Auto 230 1 10.2 1 60 80 36 1 --- Y Y
E165 / E4165 Single / Double Non 230 1 10.2 1 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y Y
* H165 Single Auto 200 1 12.6 1 60 80 36 1 --- Y N
* I165 / I4165 Single / Double Non 200 1 12.6 1 60 80 / 87 36 / 39 2 or 3 & 5 4 & 5 Y N
* J165 / J4165 Single / Double Non 200 3 7.5 1 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* F165 / F4165 Single / Double Non 230 3 7.4 1 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* G165 / G4165 Single / Double Non 460 3 3.7 1 60 80 / 87 36 / 39 3 & 5 4 & 5 Y Y
* BA165/BA4165 Single / Double Non 575 3 3.0 1 60 80 / 87 36 / 39 3 & 5 4 & 5 Y N
* no molded plug (1) UL listed unit available with 20 Amp plug. (2) CSA approval with 20 Amp plug. (3) 20 Amp outlet, P/N 10-0060 must be used. Additional cords lengths are available in 25' (8 m), 35' (11 m), and 50' (15 m).
TOTAL DYNAMIC HEAD FLOW PER MINUTE
All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).CAUTION
© Copyright 2014 Zoeller Co. All rights reserved.502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | www.zoeller.com
TECHNICAL DATA SHEETHIGH HEAD FLOW-MATE SERIESModels X161, X163, X165 Effluent Pumps
Class I, Division 1, Group C & D Rated
AUTOMATIC
NONAUTOMATIC
PRODUCT SPECIFICATIONS
NOTE: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with nonautomatic pumps.
MO
TOR
Horse Power 1/2 (X161, X163) or 1 (X165)
Voltage 115 - 575
Phase 1 or 3 Ph
Hertz 60 Hz
RPM 3450
Type Permanent split capacitor or 3 Ph
Insulation Class B
Amps 2.4 - 15.5
PU
MP
Operation Automatic or nonautomatic
Auto On/Off Points 19-1/2" (495 mm) / 9-3/4" (248 mm)
Discharge Size 1-1/2" NPT (optional 2" or 3" flange)
Solids Handling 3/4" (19 mm) spherical solids
Cord Length 20' (6 m) standard
Cord Type UL listed 5-wire (1 Ph) or 8-wire (3 Ph) SOOW
Max. Head 86.5' (26 m)
Max. Flow Rate 100 GPM (379 LPM)
Max. Operating Temp. 104° F (40° C)
Cooling Oil filled
Motor Protection Auto reset thermal overload (1 Ph) or thermal sensor (3 Ph)
MA
TE
RIA
LS
Upper Bearing Ball bearing
Lower Bearing Ball bearing
Mechanical Seals Carbon and ceramic with stainless steel parts
Impeller Type Non-clogging vortex
Impeller Bronze
Hardware Stainless steel
Motor Shaft 416 stainless steel
Gasket Neoprene square rings
NOTE: See model comparison chart for specific details.
6 1/2
8 3/4
1 1/2" NPT STANDARD2" NPTOR3" NPTAVAILABLE
22 29/32
4 9/16
4 9/16
23 9/32
1 1/2" NPTCONDUIT CONNECTION
CHECK VALVE
6 1/16
SK1912
4 9/16 8 3/4
6 1/2
1 1/2” NPT STANDARD2” NPTOR3” NPTFLANGE AVAILABLE
4 9/16
8 9/16
1 1/2” NPTCONDUIT
CONNECTION
24 15/16
21 1/2
4 29/32 6 1/16
SK2506
Standard 3600 & 3615
R
Tested to CSA Standard C22.2
No. 145
All Class 30 cast iron construction.
© Copyright 2014 Zoeller Co. All rights reserved.502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | www.zoeller.com
SELECTION GUIDE1. See FM1705 for correct intrinsically safe simplex or duplex panel
2. See FM0526 for variable level control switches rated 30VDC are used as a control activator. Quantity required dependent upon panel selection.
3. Integral float operated mechanical switch; no external control required
4. Automatic pumps: Use the optional seal-failure panel (10-1031) to enable the moisture sensor circuit if required by local codes
009920
ModelMODEL COMPARISON CERTIFICATIONS
Seal Mode Volts Ph Amps HP Hz Lbs Kg Simplex Duplex FM CSA
MX161 Single Auto 115 1 15.5 1/2 60 123 55 3 & 4 --- Y Y
NX161 Single Non 115 1 15.5 1/2 60 114 51 1 & 2 1 & 2 Y N(1)
DX161 Single Auto 230 1 7.5 1/2 60 123 55 3 & 4 --- Y Y
EX161 Single Non 230 1 7.5 1/2 60 114 51 1 & 2 1 & 2 Y Y
HX161 Single Auto 200 1 8.8 1/2 60 123 55 3 & 4 --- Y N
IX161 Single Non 200 1 8.8 1/2 60 117 53 1 & 2 1 & 2 Y N
JX161 Single Non 200 3 6.4 1/2 60 117 53 1 & 2 1 & 2 Y Y
FX161 Single Non 230 3 5.2 1/2 60 117 53 1 & 2 1 & 2 Y Y
GX161 Single Non 460 3 2.9 1/2 60 117 53 1 & 2 1 & 2 Y Y
BAX161 Single Non 575 3 2.4 1/2 60 117 53 1 & 2 1 & 2 Y N
MX163 Single Auto 115 1 15.0 1/2 60 123 55 3 & 4 --- Y Y
NX163 Single Non 115 1 15.0 1/2 60 114 55 1 & 2 1 & 2 Y N(1)
DX163 Single Auto 230 1 7.5 1/2 60 123 55 3 & 4 --- Y Y
EX163 Single Non 230 1 7.5 1/2 60 117 53 1 & 2 1 & 2 Y Y
HX163 Single Auto 200 1 8.5 1/2 60 123 55 3 & 4 --- Y N
IX163 Single Non 200 1 8.5 1/2 60 117 53 1 & 2 1 & 2 Y N
JX163 Single Non 200 3 6.0 1/2 60 117 53 1 & 2 1 & 2 Y Y
FX163 Single Non 230 3 4.8 1/2 60 117 53 1 & 2 1 & 2 Y Y
GX163 Single Non 460 3 2.9 1/2 60 117 53 1 & 2 1 & 2 Y Y
BAX163 Single Non 575 3 2.4 1/2 60 117 53 1 & 2 1 & 2 Y N
DX165 Single Auto 230 1 10.2 1 60 124 56 3 & 4 --- Y Y
EX165 Single Non 230 1 10.2 1 60 114 51 1 & 2 1 & 2 Y Y
HX165 Single Auto 200 1 12.6 1 60 124 56 3 & 4 --- Y N
IX165 Single Non 200 1 12.6 1 60 117 53 1 & 2 1 & 2 Y N
JX165 Single Non 200 3 7.5 1 60 117 53 1 & 2 1 & 2 Y Y
FX165 Single Non 230 3 7.4 1 60 117 53 1 & 2 1 & 2 Y Y
GX165 Single Non 460 3 3.7 1 60 117 53 1 & 2 1 & 2 Y Y
BAX165 Single Non 575 3 3.0 1 60 117 53 1 & 2 1 & 2 Y N
* no molded plug (1) UL listed unit available with 20 Amp plug. (2) CSA approval with 20 Amp plug. (3) 20 Amp outlet, P/N 10-0060 must be used. Additional cords lengths are available in 25' (8 m), 35' (11 m), and 50' (15 m).
TOTAL DYNAMIC HEAD FLOW PER MINUTE
All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).CAUTION
PUMP PERFORMANCE CURVEMODELS X161-X163-X165
410
GALLONSLITERS
0
0 80
10 20 30
FLOW PER MINUTE160 240
40 50 60 70
320
80 90 110
X165
TOTA
L DY
NAM
IC H
EAD
50
30
20
40
8
12
16
90
80
70
60
20
24
X163
X161
MET
ERS
FEET
100
400