TECHNICAL AND INSTALLATION MANUAL€¦ · TECHNICAL AND INSTALLATION MANUAL. 1- Completely insert...

2
Table 1: Allowable stress factor at temperatures above 93°C(200°F) To calculate the maximum allowable pressure utilise the stress factor for the relevant temperature from the table 1 above and multiply by the allowable pressure listed in table 2 for the relevant tube. Allowable working pressure Allowable stress equals to 19,500 PSI at -28°C(-20°F) to 93°C (200°F°) Safety Factor= 4( Considering tensile strength to be 75,000psi at room temperature Table 2, Allowable working pressure (PSI) TECHNICAL AND INSTALLATION MANUAL

Transcript of TECHNICAL AND INSTALLATION MANUAL€¦ · TECHNICAL AND INSTALLATION MANUAL. 1- Completely insert...

Page 1: TECHNICAL AND INSTALLATION MANUAL€¦ · TECHNICAL AND INSTALLATION MANUAL. 1- Completely insert the tube into the fitting against the shoulder to finger-tight the nut. 2- Hold the

Table 1:Allowable stress factor at temperatures above 93°C(200°F)

To calculate the maximum allowable pressure utilise thestress factor for the relevant temperature from the table1 above and multiply by the allowable pressure listed intable 2 for the relevant tube.

Allowable working pressure

Allowable stress equals to 19,500 PSI at -28°C(-20°F) to93°C (200°F°)

Safety Factor= 4( Considering tensile strength to be75,000psi at room temperature

Table 2, Allowable working pressure (PSI)

TECHNICAL AND INSTALLATION MANUAL

Page 2: TECHNICAL AND INSTALLATION MANUAL€¦ · TECHNICAL AND INSTALLATION MANUAL. 1- Completely insert the tube into the fitting against the shoulder to finger-tight the nut. 2- Hold the

1- Completely insert the tube into the fitting against the shoulder to finger-tight the nut.2- Hold the fitting steady and rotate the nut for one and a quarter turns

Size: 1/4" to 1"

1-1/4 turn from finger tight position