JTEC MCB’s are DIN rail mountable, high performance thermal/magnetic circuit breakers. Their compact dimensions, ease of mounting and excellent performance make them ideal for the overload and short circuit protection of controlcomponents and associated wiring.
Their current limiting design and high interrupt/voltage ratings make them vastly superior to residential or ‘push-to-reset’ MCBs.
They are available in Supplementary (JTECUL) or Branch rated (JTEC489) versions in 1, 2 and 3 pole units, and offer industry standard trip curves. (B,C,D and K). Amp ratings available are 1/2A – 63A in both versions.
Features and benefits common to both• Current and energy limiting design reduces damage caused by short circuits.• Higher voltage and amp ratings allow design flexibility.• Dual DIN rail mount feature makes replacement easier in tight spaces.• Optical indicator window shows contact status independent of toggle position.• Can be reverse fed if toggle has to be oriented in a specific direction in a panel.• DC versions are available up to 125VDC (1P) or 250VDC (2P in series)• Extra set of terminal screws for easy power pickup points or optional busbar feature.• Terminal screws are recessed to provide ‘finger safe’ protection.• Full range of accessories available.
12
3
4
5
678
910
11
12
JTEC MCB’s
Anatomy of a High Performance MCB1 - Box terminal2 - Busbar aperture3 - Hammer action solenoid4 - Actuator handle5 - Moving Contact6 - Busbar aperture
7 - Box terminal8 - DIN clip9 - Thermal element10 - Arc runner11 - Trip bar12 - Arc chamber
Table of contentsJTec McBs
-
33
Table of contentsJTec McBs
33
to UL508
JTEC489JTEC489 MCBs are approved to UL489 as ‘Branch Circuit’ overcurrent devices. In addition to having the same capabilities of the supplemental MCBs, they are also approved for use as a main incoming feeder or for field wiring applications. High 10kA interrupting rating is maintained up to 63A.
They are available in a wide variety of amp ratings and trip curves so they can be matched to the circuit requirements. JTEC489 MCBs can be used in place of Supplemental protectors.
JTEC489 MCB’s are available with a wide variety of accessories to expand their capabilities.
1/2 - 63A 277/480VacNote* 35-63A 240VACB, C, D & K Trip Curves1, 2, 3 Pole versions.
JTECULJTECUL MCBs are certified as ‘Supplemental Protectors’ to UL1077 (CSA 235) and are intended for the overload and short circuit protection of individual control components. Supplemental devices are typically used on the load side of branch circuit devices to ‘Supplement’ the branch rated device. They are available in a wide range of current ratings and trip characteristics that allow them to be matched to the protection requirements of individual control devices.
JTECUL MCBs are also certified to UL508 as Manual Motor controllers and can be used for direct across the line starting of individual or groups of motors. They are marked ‘Suitable for use as motor disconnect’ to meet emerging inspection requirements. They are not intended to be used in applications requiring a Branch rated device.
JTECUL MCB’s can be matched with a wide variety of accessoriesto expand their capabilities.
1/2 - 63A 277/480VacB, C, D Trip curves1, 2, 3 Pole versions.
JTEC MCB’s
33
to UL508
JTEC489JTEC489 MCBs are approved to UL489 as ‘Branch Circuit’ overcurrent devices. In addition to having the same capabilities of the supplemental MCBs, they are also approved for use as a main incoming feeder or for field wiring applications. High 10kA interrupting rating is maintained up to 63A.
They are available in a wide variety of amp ratings and trip curves so they can be matched to the circuit requirements. JTEC489 MCBs can be used in place of Supplemental protectors.
JTEC489 MCB’s are available with a wide variety of accessories to expand their capabilities.
1/2 - 63A 277/480VacNote* 35-63A 240VACB, C, D & K Trip Curves1, 2, 3 Pole versions.
JTECULJTECUL MCBs are certified as ‘Supplemental Protectors’ to UL1077 (CSA 235) and are intended for the overload and short circuit protection of individual control components. Supplemental devices are typically used on the load side of branch circuit devices to ‘Supplement’ the branch rated device. They are available in a wide range of current ratings and trip characteristics that allow them to be matched to the protection requirements of individual control devices.
JTECUL MCBs are also certified to UL508 as Manual Motor controllers and can be used for direct across the line starting of individual or groups of motors. They are marked ‘Suitable for use as motor disconnect’ to meet emerging inspection requirements. They are not intended to be used in applications requiring a Branch rated device.
JTECUL MCB’s can be matched with a wide variety of accessoriesto expand their capabilities.
1/2 - 63A 277/480VacB, C, D Trip curves1, 2, 3 Pole versions.
JTEC MCB’s
-
4 4
B trip - very fast(3-5x rating)Sensitive electronic equipment with no inherent surges or momentary overloads.
•Solidstatedevices •Switchingpowersupplies • InputsandoutputsforPLC’s
C trip - normal trip (5-10x rating)Mixedloadswithsomemotor,transformerorsolenoid content.
•Generalsmallpanelcontrolwithmixeddevices •HVACcontrol •Lightingcontrolpanels •Discreteprotectionoflightingballast •Machinetools •Mobileequipment,trailers •Vendingmachines,ATM’s •Marineelectricalsystems
D trip - slow blow trip (10-20x rating)Circuitsconsistingprimarilyofmotor,transformer or solenoid/coil content.
•Motorstarters •Pumpcontrolpanels •Compressorandpumppanels •Generatorpanels •Capacitorapplication •Transformerprimaryprotection.•Solenoids.
K trip (489 only) - slow blow trip (10 to16x rating)Sameasfor“D”withslightlylessdelay.Aspecialcurvedevelopedbyothermanufacturers.
application
TheTripcurvereferstotheinstantaneoustripcurrent.(ie:Shortcircuit)inmultiplesofMCBrating.Triptimesonoverloadarethesameforallcurves.
application JTec McB type Trip curve% of device or circuit
full load rating
Generalcircuitprotection-mainlyresistive 489 C 125%
Circuitswithcoils/solenoids/transformers 489 CorD 125%
Lightingballast 489orUL D 200%
Heatersandresistors 489orUL C 125%
Transformer 489 DorK 125%
Transformersecondary 489 CorD 125%
MotorCircuits(5secrunupmax) 489(1-10A) D 175%
489(12-63A) D 125%
UL(1-10A) D 200%
UL(12-63A) D 300%
Electronic devices 489orUL B 125%
Cableprotection 489 C 100%ofcablerating
Capacitors 489orUL D 200%
De-rating for Temperature and multiple devices.
IfcircuitloadingdoesnotexceedtheCanadianElectricalCoderequirementof80%,thenthiseffectively buildsina‘buffer’forhigherambientormultiplepoles.De-ratingisonlyrequiredifthefollowingconditions are exceeded.
Ambienttemperature >40*C De-rateby0.5%foreverydegreeover30*
Multiplepoles >5 De-rateby1%foreveryadditionalpole.
MCB Application Table
-
55
JTec series Technical data
General specifications JTecuL JTec489
Compliance SupplementaltoUL1077(CSA235)
BranchratedtoUL489(CSANo.5)
ULmotordisconnectstandard UL508 N/A
IECstandard IEC/EN60898,DIN43880
Approvalmarks cURus(1077),cULus(UL508),IEC,CE
cULus,IEC,CE
Ambienttemperaturemin/max -25*to+60*C
Mounting position Any
Degreeofprotection IP20
Mechanicallifeexpectancy 100,000on/offcycles
Electricallifeexpectancy 6,000on/offcycles
VibrationresistanceG/HZ 3G’s(8-50HZ)
Reversefeedcapability Yes
electrical specifications
Ampratingsavailable1/2,1,1.6,2,3,4,5,6,7,8,9,10,13,15,16,20,25,30,32,40,50,60,63A
1/2,1,1.6,2,3,4,5,6,7,8,9,10,13,15,16,20,25,30,40,50,60,63A
Numberofpollsavailable 1P,2P,3P,1P+N,3P+N
Tripcurvesavailable B,C,D B,C,D,K
Ratedvoltage-standardmodels AC 277/480Y 277/480Yto32A240Vac40-63A
DCversions DC N/A 125Vdc1P/250Vdc2polesinseries
Ratedfrequency(AC) HZ 50/60HZ
InterruptingRatings
277/480Y
1/2-6A10kA 10kAupto32A
7-63A5kAw/outbackupfuse -
7-63A10kAwithbackupfuse -
347/600Y*
1/2-63A2kAw/outbackupfuse -
1/2-63A5kAwithbackupfuse -
10kAwithbackupfuse,5kAw/out -
InterruptingRating 240Vac 10kAupto63A
60DC* 10kAupto63A
Interruptingratings-DCversions 125Vdc 10kAupto63A
250Vdc 10kA-2Polesinseries
Backupfuserating 600Vac CSA/ULClassJ-4XMCBrating N/A
MagneticTrip(instantaneous) B 3-5Xcurrentrating
C 5-10Xcurrentrating
D 10-20Xcurrentrating
K N/A 10-16Xcurrentrating
OverloadTripxIn 1.13-1.45currentratingin
-
6 6
Trip curves for JTec489 & JTecuL
Tripping Characteristic of JTEC489
Circuit Breaker (In 10)
General specifications
-
77
JTec accessories
JTec accessories
JTecuL JTec489
auxiliary contacts
OperatesintandemwithMCB.
Useforremotesignallingorswitching applications.
MountstosideofMCBwith
fieldkit.
1FormC JTECULAUX1CO JTEC489AUX1CO
2FormC JTECULAUX2CO JTEC489AUX2CO
1formC+signal JTECULAUXSCO JTEC489AUXSCO
1formC+signal+test JTECULAUXSTCO JTEC489AUXSTCO
shunt trip
UseforremotelytrippingtheJTECbreaker.
MountstosideofMCBwith
fieldkit.
12Vac JTECULST12AC JTEC489ST12AC
24Vac JTECULST24AC JTEC489ST24AC
120Vac JTECULST120AC JTEC489ST120AC
230Vac JTECULST230AC JTEC489ST230AC
24Vdc JTECULST24DC JTEC489ST24DC
48Vdc JTECULST48DC JTEC489ST48DC
110Vdc JTECULST110DC JTEC489ST110DC
neutral pole
Useforaddingaswitched
NeutralpoletoanyJTECMCB.
MountstosideofMCBwith
fieldkit.
1/2-63Amp JTECULN2 JTEC489N2
undervoltage release
Useforautomaticallytrippingthebreakerincaseofpowerloss.
MountstosideofMCBwith
fieldkit.
12Vac use 489 series JTEC489UV12AC
24Vac use 489 series JTEC489UV24AC
120Vac use 489 series JTEC489UV110AC
230Vac use 489 series JTEC489UV230AC
24Vdc use 489 series JTEC489UV24DC
48Vdc use 489 series JTEC489UV48DC
110Vdc use 489 series JTEC489UV110DC
safety lockout device
Usetolockthetoggleinopenor closed position to prevent tampering.(note:MCBcontactswillstilltripfeeeveninlocked‘On’position.)
Requirespadlockswith4mm(5/32”)orsmallerhasps.
Yellow
JTECLP1YELLOW
Black
JTECLP1BLACK
-
8 8
accessory specifications
PowerTerm.Capacity #20-#12AWG(2.5-25mm2)
Tighteningtorque 3-4inlbs(.33-0.5Nm)
Aux.&Signalterm.WireCapacity #20-#12AWG(0.5-2.5mm2)
Tighteningtorque 3-4inlbs(.33-0.5Nm)
Auxiliarycontactratings 6A@120Vac,3A@250Vac
Busbarampacity 125Aifcenterfed,80Aiffedfromoneend.
JTecuL JTec489
Busbar
UseBusbarstoparallelmultipolestosavelabourandneateninstallation.
PINtypefitsinplaceofwire.Spade type fits under screw ter-minal,leavingwireterminalfree.
pending
1 phase pin terminal BBTEC1PPIN16
2 phase pin terminal BBTEC2PPIN16
3 phase pin terminal. BBTEC3PPIN16
1 phase spade terminal BBTEC1PCOMB20
2 phase spade terminal BBTEC2PCOMB16
3 phase spade terminal BBTEC3PCOMB16
Busbar connector terminal.
Usetoconnectcablefeedtobusbar.
Powerfeedconnector
#1AWG-Max125ABBTECECCT35 -
Busbar cut end-cap.
Usetoinsulatebusbarendaftercutting. End cap BBTECEC3P16 -
Front Mount Panel adapter
UsedformountingMCB’sto rearofpaneldoor JTECFMA1P(1pole)
JTECFMA2P(2pole)
JTECFMA3P(3pole)
Panel mount adapter clip.
ReplacesDINrailmounts.UseforscrewmountingMCB’sdirectly to panel.
JTECPANELCLIP
ForJTEC489useplasticornylon
screws due to clearances.
JTec accessories continued
-
99
Ordering Code - AC
Ordering Code - DC (489 only)
10
*special current ratings available on request
UL = Supplementary489 = Branch Rated
JTEC UL 22 B 10
JTEC SeriesNo. Poles UL (1, 2, 3)No. Poles 489 (1, 2, 3)
RED = JTEC UL SeriesBLUE = JTEC 489 Series
UL Trip Curve (B, C, D)489 Trip Curve (B, C, K, D)
Amp Rating (0.5 - 63A)Amp Rating (0.2 - 63A)
489 = Branch Rated
JTECDC 489 B 10
JTEC Series
22
No. Poles 489 (1, 2, 3) 489 Trip Curve (B, C, K, D) Amp Rating (0.2 - 63A)
Ordering
0.5714.5
109.
6 4
.3
69 2
.72
17.5
0.69 2.071.38
52.535
6.50.26
44 1.73
60 2.36
45 1.77
Red = mmBlue = inches
JTE
C U
L 85
.5 3
.36
JTE
C 4
89 1
09.7
4.3
2
JTEC489 outlineJTECUL outline
dimensions
-
10 10
LedTec Pilot Lights
• VerybrightLEDbulb• Standard22mmformat• Directwiretointegralrearterminals• Shockresistant• Oilanddusttight• 1piecedesign-onepartnumber
LEDtec’sareLEDpilotlightsutilizingmulti-chiptechnologytoprovidebright,evenlylitcolour.Theirsolidstatedesignandlonglifemakesincandescentbulbsathingofthepast.Theaestheticallypleasingdesignfitsinwellwithcurrentpaneldesigns.LEDtecsmountintostandard22mm(7/8)knockouts,haveasinglerearlocknutandhaveintegralscrewclampterminalsforeasywiring.Theyareavailableinstandardcoloursandcontrol voltages.
29
50 36
20
21.8
7
7
12.5
Colouredcap
Whitediffuserinsert
Rubbergasket
M22 x 1.5 threads
Knurlednut
Removableterminalshroud
Specifications
Voltages 12Vac/dc,24Vac/dc,48Vac/dc,110/120Vac,110/120Vdc,230Vac
IPRating IP65
Colours Red,Green,Amber,Blue,White Temperaturerange -25oC60+55oC
Lifeexpectancy 30,000 hours Relative humidity up to 98%
Di-Electricwithstand 2.5kVacfor1minute Tighteningtorque 0.9Nm
Voltagetolerance +20%(lowervoltagesarenotaproblembutwillreducelightoutput.
CurrentDraw 6-12V≤20ma24V≤15ma120V≤10ma240V≤4ma
Frequency 50-60HZ Approvals
WiththenewBCR-AXadapterring,goingfrom30mmto22mmtakesonlyafewseconds..
• Steelplatedbackingringwith anti-rotationnotch
• Fitspanelthicknessupto14gauge
• Notoolsrequired
• Availableinblackplasticorchromed metalbezel.
- PlasticbezelBCR-AX
- ChromedmetalbezelBCR-AM
BCRAX
diam. -
Panelknockoutdimensions
22.2mm
Dimensions in MM
LEDTEC Series
LEDTEC
Catalogue number example
120Vac/dc
12Vac/dc24Vac/dc48Vac/dc110/120Vac110/120Vdc230Vac
R=RedG=GreenA= AmberB=BlueW=White
R
30mmto22mmAdapter
-
1111
BA9SLED’sarehighbrightnessLEDbulbswithindustrystandardBA9Sbayonetbases.Theywillfitintoanystandard22mmor30mmpilotlightthatacceptsBA9Sbulbs.Theirsolidstatedesignandlonglifemakesincandescentbulbsathingofthepast.LEDBA9sareavailableinindustrystandardcolorsandvoltageratingsandallowsLEDupgradefromthefrontofthepanelwithouthavingtoopenthedoor.
• HighbrightnesssingleLEDchip• Flattopprovidessuperiorlightdispersion.• Willfitmostpilotlightsandilluminateddevices.• Lowenergyconsumption(
-
Tec
hn
a P
ro
du
cTs
599 norrIs courT KInGsTon, onTarIo canada K7P 2r9 TEL: 613.384.4144 • FAX: 613.384.0167
ToLL FrEE: 800.479.3875 • ToLL FrEE FAX: 800.866.7690 EMAIL: [email protected] • WEB: WWW.FusETEk.coM PrintedinCANADA