    JTEC MCB’s are DIN rail mountable, high performance thermal/magnetic circuit breakers. Their compact dimensions, ease of mounting and excellent performance make them ideal for the overload and short circuit protection of controlcomponents and associated wiring.

    Their current limiting design and high interrupt/voltage ratings make them vastly superior to residential or ‘push-to-reset’ MCBs.

    They are available in Supplementary (JTECUL) or Branch rated (JTEC489) versions in 1, 2 and 3 pole units, and offer industry standard trip curves. (B,C,D and K). Amp ratings available are 1/2A – 63A in both versions.

    Features and benefits common to both• Current and energy limiting design reduces damage caused by short circuits.• Higher voltage and amp ratings allow design flexibility.• Dual DIN rail mount feature makes replacement easier in tight spaces.• Optical indicator window shows contact status independent of toggle position.• Can be reverse fed if toggle has to be oriented in a specific direction in a panel.• DC versions are available up to 125VDC (1P) or 250VDC (2P in series)• Extra set of terminal screws for easy power pickup points or optional busbar feature.• Terminal screws are recessed to provide ‘finger safe’ protection.• Full range of accessories available.

    12

    3

    4

    5

    678

    910

    11

    12

    JTEC MCB’s

    Anatomy of a High Performance MCB1 - Box terminal2 - Busbar aperture3 - Hammer action solenoid4 - Actuator handle5 - Moving Contact6 - Busbar aperture

    7 - Box terminal8 - DIN clip9 - Thermal element10 - Arc runner11 - Trip bar12 - Arc chamber

    Table of contentsJTec McBs

  • 33

    Table of contentsJTec McBs

    33

    to UL508

    JTEC489JTEC489 MCBs are approved to UL489 as ‘Branch Circuit’ overcurrent devices. In addition to having the same capabilities of the supplemental MCBs, they are also approved for use as a main incoming feeder or for field wiring applications. High 10kA interrupting rating is maintained up to 63A.

    They are available in a wide variety of amp ratings and trip curves so they can be matched to the circuit requirements. JTEC489 MCBs can be used in place of Supplemental protectors.

    JTEC489 MCB’s are available with a wide variety of accessories to expand their capabilities.

    1/2 - 63A 277/480VacNote* 35-63A 240VACB, C, D & K Trip Curves1, 2, 3 Pole versions.

    JTECULJTECUL MCBs are certified as ‘Supplemental Protectors’ to UL1077 (CSA 235) and are intended for the overload and short circuit protection of individual control components. Supplemental devices are typically used on the load side of branch circuit devices to ‘Supplement’ the branch rated device. They are available in a wide range of current ratings and trip characteristics that allow them to be matched to the protection requirements of individual control devices.

    JTECUL MCBs are also certified to UL508 as Manual Motor controllers and can be used for direct across the line starting of individual or groups of motors. They are marked ‘Suitable for use as motor disconnect’ to meet emerging inspection requirements. They are not intended to be used in applications requiring a Branch rated device.

    JTECUL MCB’s can be matched with a wide variety of accessoriesto expand their capabilities.

    1/2 - 63A 277/480VacB, C, D Trip curves1, 2, 3 Pole versions.

    JTEC MCB’s

    33

    to UL508

    JTEC489JTEC489 MCBs are approved to UL489 as ‘Branch Circuit’ overcurrent devices. In addition to having the same capabilities of the supplemental MCBs, they are also approved for use as a main incoming feeder or for field wiring applications. High 10kA interrupting rating is maintained up to 63A.

    They are available in a wide variety of amp ratings and trip curves so they can be matched to the circuit requirements. JTEC489 MCBs can be used in place of Supplemental protectors.

    JTEC489 MCB’s are available with a wide variety of accessories to expand their capabilities.

    1/2 - 63A 277/480VacNote* 35-63A 240VACB, C, D & K Trip Curves1, 2, 3 Pole versions.

    JTECULJTECUL MCBs are certified as ‘Supplemental Protectors’ to UL1077 (CSA 235) and are intended for the overload and short circuit protection of individual control components. Supplemental devices are typically used on the load side of branch circuit devices to ‘Supplement’ the branch rated device. They are available in a wide range of current ratings and trip characteristics that allow them to be matched to the protection requirements of individual control devices.

    JTECUL MCBs are also certified to UL508 as Manual Motor controllers and can be used for direct across the line starting of individual or groups of motors. They are marked ‘Suitable for use as motor disconnect’ to meet emerging inspection requirements. They are not intended to be used in applications requiring a Branch rated device.

    JTECUL MCB’s can be matched with a wide variety of accessoriesto expand their capabilities.

    1/2 - 63A 277/480VacB, C, D Trip curves1, 2, 3 Pole versions.

    JTEC MCB’s

  • 4 4

    B trip - very fast(3-5x rating)Sensitive electronic equipment with no inherent surges or momentary overloads.

    •Solidstatedevices •Switchingpowersupplies • InputsandoutputsforPLC’s

    C trip - normal trip (5-10x rating)Mixedloadswithsomemotor,transformerorsolenoid content.

    •Generalsmallpanelcontrolwithmixeddevices •HVACcontrol •Lightingcontrolpanels •Discreteprotectionoflightingballast •Machinetools •Mobileequipment,trailers •Vendingmachines,ATM’s •Marineelectricalsystems

    D trip - slow blow trip (10-20x rating)Circuitsconsistingprimarilyofmotor,transformer or solenoid/coil content.

    •Motorstarters •Pumpcontrolpanels •Compressorandpumppanels •Generatorpanels •Capacitorapplication •Transformerprimaryprotection.•Solenoids.

    K trip (489 only) - slow blow trip (10 to16x rating)Sameasfor“D”withslightlylessdelay.Aspecialcurvedevelopedbyothermanufacturers.

    application

    TheTripcurvereferstotheinstantaneoustripcurrent.(ie:Shortcircuit)inmultiplesofMCBrating.Triptimesonoverloadarethesameforallcurves.

    application JTec McB type Trip curve% of device or circuit

    full load rating

    Generalcircuitprotection-mainlyresistive 489 C 125%

    Circuitswithcoils/solenoids/transformers 489 CorD 125%

    Lightingballast 489orUL D 200%

    Heatersandresistors 489orUL C 125%

    Transformer 489 DorK 125%

    Transformersecondary 489 CorD 125%

    MotorCircuits(5secrunupmax) 489(1-10A) D 175%

    489(12-63A) D 125%

    UL(1-10A) D 200%

    UL(12-63A) D 300%

    Electronic devices 489orUL B 125%

    Cableprotection 489 C 100%ofcablerating

    Capacitors 489orUL D 200%

    De-rating for Temperature and multiple devices.

    IfcircuitloadingdoesnotexceedtheCanadianElectricalCoderequirementof80%,thenthiseffectively buildsina‘buffer’forhigherambientormultiplepoles.De-ratingisonlyrequiredifthefollowingconditions are exceeded.

    Ambienttemperature >40*C De-rateby0.5%foreverydegreeover30*

    Multiplepoles >5 De-rateby1%foreveryadditionalpole.

    MCB Application Table

  • 55

    JTec series Technical data

    General specifications JTecuL JTec489

    Compliance SupplementaltoUL1077(CSA235)

    BranchratedtoUL489(CSANo.5)

    ULmotordisconnectstandard UL508 N/A

    IECstandard IEC/EN60898,DIN43880

    Approvalmarks cURus(1077),cULus(UL508),IEC,CE

    cULus,IEC,CE

    Ambienttemperaturemin/max -25*to+60*C

    Mounting position Any

    Degreeofprotection IP20

    Mechanicallifeexpectancy 100,000on/offcycles

    Electricallifeexpectancy 6,000on/offcycles

    VibrationresistanceG/HZ 3G’s(8-50HZ)

    Reversefeedcapability Yes

    electrical specifications

    Ampratingsavailable1/2,1,1.6,2,3,4,5,6,7,8,9,10,13,15,16,20,25,30,32,40,50,60,63A

    1/2,1,1.6,2,3,4,5,6,7,8,9,10,13,15,16,20,25,30,40,50,60,63A

    Numberofpollsavailable 1P,2P,3P,1P+N,3P+N

    Tripcurvesavailable B,C,D B,C,D,K

    Ratedvoltage-standardmodels AC 277/480Y 277/480Yto32A240Vac40-63A

    DCversions DC N/A 125Vdc1P/250Vdc2polesinseries

    Ratedfrequency(AC) HZ 50/60HZ

    InterruptingRatings

    277/480Y

    1/2-6A10kA 10kAupto32A

    7-63A5kAw/outbackupfuse -

    7-63A10kAwithbackupfuse -

    347/600Y*

    1/2-63A2kAw/outbackupfuse -

    1/2-63A5kAwithbackupfuse -

    10kAwithbackupfuse,5kAw/out -

    InterruptingRating 240Vac 10kAupto63A

    60DC* 10kAupto63A

    Interruptingratings-DCversions 125Vdc 10kAupto63A

    250Vdc 10kA-2Polesinseries

    Backupfuserating 600Vac CSA/ULClassJ-4XMCBrating N/A

    MagneticTrip(instantaneous) B 3-5Xcurrentrating

    C 5-10Xcurrentrating

    D 10-20Xcurrentrating

    K N/A 10-16Xcurrentrating

    OverloadTripxIn 1.13-1.45currentratingin

  • 6 6

    Trip curves for JTec489 & JTecuL

    Tripping Characteristic of JTEC489

    Circuit Breaker (In 10)

    General specifications

  • 77

    JTec accessories

    JTec accessories

    JTecuL JTec489

    auxiliary contacts

    OperatesintandemwithMCB.

    Useforremotesignallingorswitching applications.

    MountstosideofMCBwith

    fieldkit.

    1FormC JTECULAUX1CO JTEC489AUX1CO

    2FormC JTECULAUX2CO JTEC489AUX2CO

    1formC+signal JTECULAUXSCO JTEC489AUXSCO

    1formC+signal+test JTECULAUXSTCO JTEC489AUXSTCO

    shunt trip

    UseforremotelytrippingtheJTECbreaker.

    MountstosideofMCBwith

    fieldkit.

    12Vac JTECULST12AC JTEC489ST12AC

    24Vac JTECULST24AC JTEC489ST24AC

    120Vac JTECULST120AC JTEC489ST120AC

    230Vac JTECULST230AC JTEC489ST230AC

    24Vdc JTECULST24DC JTEC489ST24DC

    48Vdc JTECULST48DC JTEC489ST48DC

    110Vdc JTECULST110DC JTEC489ST110DC

    neutral pole

    Useforaddingaswitched

    NeutralpoletoanyJTECMCB.

    MountstosideofMCBwith

    fieldkit.

    1/2-63Amp JTECULN2 JTEC489N2

    undervoltage release

    Useforautomaticallytrippingthebreakerincaseofpowerloss.

    MountstosideofMCBwith

    fieldkit.

    12Vac use 489 series JTEC489UV12AC

    24Vac use 489 series JTEC489UV24AC

    120Vac use 489 series JTEC489UV110AC

    230Vac use 489 series JTEC489UV230AC

    24Vdc use 489 series JTEC489UV24DC

    48Vdc use 489 series JTEC489UV48DC

    110Vdc use 489 series JTEC489UV110DC

    safety lockout device

    Usetolockthetoggleinopenor closed position to prevent tampering.(note:MCBcontactswillstilltripfeeeveninlocked‘On’position.)

    Requirespadlockswith4mm(5/32”)orsmallerhasps.

    Yellow

    JTECLP1YELLOW

    Black

    JTECLP1BLACK

  • 8 8

    accessory specifications

    PowerTerm.Capacity #20-#12AWG(2.5-25mm2)

    Tighteningtorque 3-4inlbs(.33-0.5Nm)

    Aux.&Signalterm.WireCapacity #20-#12AWG(0.5-2.5mm2)

    Tighteningtorque 3-4inlbs(.33-0.5Nm)

    Auxiliarycontactratings 6A@120Vac,3A@250Vac

    Busbarampacity 125Aifcenterfed,80Aiffedfromoneend.

    JTecuL JTec489

    Busbar

    UseBusbarstoparallelmultipolestosavelabourandneateninstallation.

    PINtypefitsinplaceofwire.Spade type fits under screw ter-minal,leavingwireterminalfree.

    pending

    1 phase pin terminal BBTEC1PPIN16

    2 phase pin terminal BBTEC2PPIN16

    3 phase pin terminal. BBTEC3PPIN16

    1 phase spade terminal BBTEC1PCOMB20

    2 phase spade terminal BBTEC2PCOMB16

    3 phase spade terminal BBTEC3PCOMB16

    Busbar connector terminal.

    Usetoconnectcablefeedtobusbar.

    Powerfeedconnector

    #1AWG-Max125ABBTECECCT35 -

    Busbar cut end-cap.

    Usetoinsulatebusbarendaftercutting. End cap BBTECEC3P16 -

    Front Mount Panel adapter

    UsedformountingMCB’sto rearofpaneldoor JTECFMA1P(1pole)

    JTECFMA2P(2pole)

    JTECFMA3P(3pole)

    Panel mount adapter clip.

    ReplacesDINrailmounts.UseforscrewmountingMCB’sdirectly to panel.

    JTECPANELCLIP

    ForJTEC489useplasticornylon

    screws due to clearances.

    JTec accessories continued

  • 99

    Ordering Code - AC

    Ordering Code - DC (489 only)

    10

    *special current ratings available on request

    UL = Supplementary489 = Branch Rated

    JTEC UL 22 B 10

    JTEC SeriesNo. Poles UL (1, 2, 3)No. Poles 489 (1, 2, 3)

    RED = JTEC UL SeriesBLUE = JTEC 489 Series

    UL Trip Curve (B, C, D)489 Trip Curve (B, C, K, D)

    Amp Rating (0.5 - 63A)Amp Rating (0.2 - 63A)

    489 = Branch Rated

    JTECDC 489 B 10

    JTEC Series

    22

    No. Poles 489 (1, 2, 3) 489 Trip Curve (B, C, K, D) Amp Rating (0.2 - 63A)

    Ordering

    0.5714.5

    109.

    6 4

    .3

    69 2

    .72

    17.5

    0.69 2.071.38

    52.535

    6.50.26

    44 1.73

    60 2.36

    45 1.77

    Red = mmBlue = inches

    JTE

    C U

    L 85

    .5 3

    .36

    JTE

    C 4

    89 1

    09.7

    4.3

    2

    JTEC489 outlineJTECUL outline

    dimensions

  • 10 10

    LedTec Pilot Lights

    • VerybrightLEDbulb• Standard22mmformat• Directwiretointegralrearterminals• Shockresistant• Oilanddusttight• 1piecedesign-onepartnumber

    LEDtec’sareLEDpilotlightsutilizingmulti-chiptechnologytoprovidebright,evenlylitcolour.Theirsolidstatedesignandlonglifemakesincandescentbulbsathingofthepast.Theaestheticallypleasingdesignfitsinwellwithcurrentpaneldesigns.LEDtecsmountintostandard22mm(7/8)knockouts,haveasinglerearlocknutandhaveintegralscrewclampterminalsforeasywiring.Theyareavailableinstandardcoloursandcontrol voltages.

    29

    50 36

    20

    21.8

    7

    7

    12.5

    Colouredcap

    Whitediffuserinsert

    Rubbergasket

    M22 x 1.5 threads

    Knurlednut

    Removableterminalshroud

    Specifications

    Voltages 12Vac/dc,24Vac/dc,48Vac/dc,110/120Vac,110/120Vdc,230Vac

    IPRating IP65

    Colours Red,Green,Amber,Blue,White Temperaturerange -25oC60+55oC

    Lifeexpectancy 30,000 hours Relative humidity up to 98%

    Di-Electricwithstand 2.5kVacfor1minute Tighteningtorque 0.9Nm

    Voltagetolerance +20%(lowervoltagesarenotaproblembutwillreducelightoutput.

    CurrentDraw 6-12V≤20ma24V≤15ma120V≤10ma240V≤4ma

    Frequency 50-60HZ Approvals

    WiththenewBCR-AXadapterring,goingfrom30mmto22mmtakesonlyafewseconds..

    • Steelplatedbackingringwith anti-rotationnotch

    • Fitspanelthicknessupto14gauge

    • Notoolsrequired

    • Availableinblackplasticorchromed metalbezel.

    - PlasticbezelBCR-AX

    - ChromedmetalbezelBCR-AM

    BCRAX

    diam. -

    Panelknockoutdimensions

    22.2mm

    Dimensions in MM

    LEDTEC Series

    LEDTEC

    Catalogue number example

    120Vac/dc

    12Vac/dc24Vac/dc48Vac/dc110/120Vac110/120Vdc230Vac

    R=RedG=GreenA= AmberB=BlueW=White

    R

    30mmto22mmAdapter

  • 1111

    BA9SLED’sarehighbrightnessLEDbulbswithindustrystandardBA9Sbayonetbases.Theywillfitintoanystandard22mmor30mmpilotlightthatacceptsBA9Sbulbs.Theirsolidstatedesignandlonglifemakesincandescentbulbsathingofthepast.LEDBA9sareavailableinindustrystandardcolorsandvoltageratingsandallowsLEDupgradefromthefrontofthepanelwithouthavingtoopenthedoor.

    • HighbrightnesssingleLEDchip• Flattopprovidessuperiorlightdispersion.• Willfitmostpilotlightsandilluminateddevices.• Lowenergyconsumption(

  • Tec

    hn

    a P

    ro

    du

    cTs

    599 norrIs courT KInGsTon, onTarIo canada K7P 2r9 TEL: 613.384.4144 • FAX: 613.384.0167

    ToLL FrEE: 800.479.3875 • ToLL FrEE FAX: 800.866.7690 EMAIL: [email protected] • WEB: WWW.FusETEk.coM PrintedinCANADA

    Ref/TECH201