Alcatel-Lucent GSM TC Corrective Maintenance Handbook BSC & TC Document Procedural Handbook Release B10 3BK 21256 AAAA PCZZA Ed.10

description

TC Corrective Maintenance

Transcript of TC Corrective Maintenance

  • Alcatel-Lucent GSM

    TC Corrective Maintenance

    Handbook

    BSC & TC Document

    Procedural Handbook

    Release B10

    3BK 21256 AAAA PCZZA Ed.10

  • Status RELEASED

    Short title Maintenance Handbook

    All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel-Lucent.

    BLANK PAGE BREAK

    2 / 38 3BK 21256 AAAA PCZZA Ed.10

  • Contents

    ContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Safety Rules and Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    1.1 Safety Rules for Equipment Under Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2 Electrostatic Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    1.2.1 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2.2 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2.3 Transportation and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.2.4 Components and PBAs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.2.5 Handling Optical Fiber Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2.6 Handling Coaxial and Optical Fiber Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    2 G2 TC Transmission RITs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.1 Before You Start to Replace Transmission RITs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    2.1.1 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.1.2 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.1.3 Impact on System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.1.4 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    2.2 Replace Transmission RITs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 9125 TC RITs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    3.1 Replace MT120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183.1.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183.1.2 Impact on System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193.1.3 Procedure 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203.1.4 Procedure 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    3.2 Replace JBTCIF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.2.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.2.2 Impact on System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.2.3 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.2.4 Install the New Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.2.5 Upgrade the STM-1 Daughter Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    3.3 Replace FANU for MT120 Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.3.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.3.2 Impact on System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.3.3 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    3.4 Replace FANU for TCIF Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.4.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.4.2 Impact on System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.4.3 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    3BK 21256 AAAA PCZZA Ed.10 3 / 38

  • Tables

    TablesTable 1: Transmission RITs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    4 / 38 3BK 21256 AAAA PCZZA Ed.10

  • Preface

    PrefacePurpose The TC Corrective Maintenance Handbook describes how to perform TC

    maintenance. It breaks down each maintenance task into a series ofstep-by-step instructions, and tells you what tools and materials are required.The handbook covers the following equipment configurations:

    G2 TC

    9125 TC.

    Note: Your network may not have some of the hardware included in the handbook.For more information about these configurations, refer to the functionaldescription documents.The Alcatel-Lucent Radio Solutions include the G2 TC and 9125 TC equipmentdescribed in this document:

    Whats New In Edition 10Description improvement in:

    Replace JBTCIF (Section 3.2)Install the New Board (Section 3.2.4)

    .

    In Edition 09Description improvement in:

    Tools and Materials (Section 3.1.1)MT120 in HSI or MT120 in TCIL with Direct Connection to the Board(Section 3.1.3.2)Replace JBTCIF (Section 3.2).

    3BK 21256 AAAA PCZZA Ed.10 5 / 38

  • Preface

    In Edition 08Description improvement in:

    Replace MT120 Board for G2 TC and 9125 TC not Equipped with STM1-IPSubrack (Section 3.1.4.1)Replace MT120 Board in 9125 TC Equipped with STM1-IP Subrack(Section 3.1.4.2)Replace JBTCIF (Section 3.2).

    In Edition 07Section Replace JBTCIF (Section 3.2) was added.Description improvement in:

    Replace MT120 Board for G2 TC and 9125 TC not Equipped with STM1-IPSubrack (Section 3.1.4.1)Replace MT120 Board in 9125 TC Equipped with STM1-IP Subrack(Section 3.1.4.2).

    In Edition 06The following sections were updated:

    Replace FANU for TCIF Boards (Section 3.4)Tools and Materials (Section 3.1.1)Procedure 2 (Section 3.1.4).

    In Edition 05Description update in Procedure 2 (Section 3.1.4).

    In Edition 04Description update in Replace MT120 (Section 3.1).

    In Edition 03Update for new equipment naming.

    In Edition 02The following sections were added:

    Handling Optical Fiber Devices (Section 1.2.5)Handling Coaxial and Optical Fiber Cables (Section 1.2.6)Replace JBTCIF (Section 3.2).

    In Edition 01Creation in B10.

    6 / 38 3BK 21256 AAAA PCZZA Ed.10

  • Preface

    Audience The handbook is intended for:

    Maintenance engineers

    System support engineers

    Network technicians

    Network operators.

    Assumed Knowledge You must have a basic understanding of the following:

    Alcatel-Lucent operations and maintenance concepts for the BSS

    TSC and 9153 OMC-R terminals

    Windows XP operating system

    Telecommunications engineering

    Anti-static procedures

    RF test and measurement equipment

    Signal analyzers as used on GSM networks

    Electronic test equipment.

    3BK 21256 AAAA PCZZA Ed.10 7 / 38

  • Preface

    8 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 1 Safety Rules and Precautions

    1 Safety Rules and Precautions

    This chapter contains the following safety rules and precautions:

    Safety rules for equipment under power

    Electrostatic precautions.

    Injury from EquipmentPossible death or serious physical harm to personnel and damage to equipmentmay result from mishandling.While performing any maintenance tasks or procedures, you must follow anylocal safety requirements, and those mentioned in General Safety Instructionsfor Field Operations and this chapter.

    3BK 21256 AAAA PCZZA Ed.10 9 / 38

  • 1 Safety Rules and Precautions

    1.1 Safety Rules for Equipment Under PowerFor maintenance purposes, field operators may have to work on equipmentunder power (-48 VDC or -60 VDC). This means that it is possible to touchsome parts under power, that are only protected by heavy fuses. Maintenanceactivities must be carried out carefully to avoid short circuits and to preventserious personal injury.Remove all conductive objects from the hands, such as rings, bracelets,metallic wrist watches and so on. Use appropriate insulated tools formaintenance activities.

    1.2 Electrostatic PrecautionsThe following electrostatic precautions must be observed:

    1.2.1 Environment

    Ensure that work benches, stools, and floor mats have a conducting surfaceconnected to ground. Before handling static-sensitive components andassemblies, ground yourself to the conducting surface using an anti-staticwrist strap.

    When handling static-sensitive components and assemblies, do not wearor use clothes made of wool, nylon or any other synthetic material. Suchfabrics are major sources of static build-up.When handling static-sensitive components and assemblies, do not usegloves and finger covers, unless they are made of cotton.

    1.2.2 Tools

    Ensure that all the tools which come into contact with static-sensitivecomponents are at the same voltage level as the conducting work surfacesand floor mats.These tools include soldering irons, oscilloscopes, power supplies, andmetal parts of tools and fixtures that are used to hold, assemble or test PBAs.

    Do not use rough cleaners or erasers to clean the gold-plated contactson PBAs.

    Do not mark a PBA with a lead pencil or any other writing instrument.

    Do not use synthetic brushes to clean equipment, and do not use drycleaning methods.

    10 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 1 Safety Rules and Precautions

    1.2.3 Transportation and StoragePack all containers used to transport and store static-sensitive components,and use aluminium container tubes if possible. If not, insert the componentterminations into electrically conductive foam.

    Before shipping a PBA, wrap it in a conducting synthetic bag or in aluminiumfoil. Also pack the PBA in a polyethylene transport box.

    Before shipping a PBA which has MOS components, ensure that anappropriate warning symbol is displayed on the package.

    Store spare PBAs in their appropriate polyethylene boxes. Keep the boxesclosed except when access to their contents is required.

    Do not store PBAs in an area where the air is polluted with smoke, dust,dangerous gases or other air-borne particles that may cause damage.

    Do not stack PBAs side-by-side or on top of each other with the boardsurfaces or components in contact with one another.

    Before cleaning a PBA, remove or disconnect the damage protection, suchas protective foam, to allow the PBA to be cleaned thoroughly. Replace thedamage protection upon completion of the task.

    1.2.4 Components and PBAsComponents and PBAs not in protective containers, must only be handledby trained personnel in static-controlled work areas.

    Before removing a PBA from an equipment rack, discharge any static bytouching the metal frame of the rack with your hand.

    Always handle a PBA by the edges.

    Do not handle or carry a PBA by any of the mounted components.

    Do not handle a PBA by the gold-plated contact terminals and do not applydirect pressure to the components.

    Do not touch PBA connection pins or conductor paths.

    Do not touch PBAs with wet hands.

    Place PBAs that have been removed during maintenance with the solderedside downwards on a conductive surface.

    Do not scratch or rub the soldered side of a PBA with a sharp or roughobject.Do not repair PBAs in the switch room.

    Do not handle components and assemblies by their leads.

    Do not use excessive force when inserting connection boards.

    3BK 21256 AAAA PCZZA Ed.10 11 / 38

  • 1 Safety Rules and Precautions

    1.2.5 Handling Optical Fiber DevicesDepending on installed options the equipment may contain fiber optic devicesthat can radiate laser beams:

    Do not look directly in the laser beam

    Take into account that infrared laser radiation is not visible. Additional labelscan be added to classify the laser.

    Respect the warnings given by labels provided on equipment.

    1.2.6 Handling Coaxial and Optical Fiber CablesWhen handling coaxial or optical fiber cables:

    Do not cut coaxial or optical fiber cables to adjust the cable length.Do not bend to tighten the coaxial or optical fiber cable.Furthermore, for handling coaxial or optical fiber cables respect the cablemanufacturer specifications.

    12 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 2 G2 TC Transmission RITs

    2 G2 TC Transmission RITs

    This chapter tells you how to remove and replace Transmission RITs of theTC G2

    3BK 21256 AAAA PCZZA Ed.10 13 / 38

  • 2 G2 TC Transmission RITs

    2.1 Before You Start to Replace Transmission RITsRead this section before starting the procedure in this chapter.

    2.1.1 PrerequisitesNote the following conditions. You must:

    Have read Chapter 1 before performing any maintenance procedures.

    Be familiar with electrostatic precautions. Refer to Section ElectrostaticPrecautions (Section 1.2) for more information.Know the location of the RIT to be replaced.The location of the RIT to be replaced is defined in terms of the site,cabinet, shelf and slot position. This information is obtained from the 9153OMC-R operator.

    Establish an efficient means of communication with an 9153 OMC-Roperator in order to lock (disable) and unlock (initialize) the appropriateMO (SBL) when required.

    2.1.2 Tools and MaterialsYou must have:

    An anti-static wrist strap

    A TSC terminal to configure the RIT

    A serviceable replacement RIT with an identical part number.

    2.1.3 Impact on SystemReplacing a RIT causes alarms to be sent to the 9153 OMC-R. If thereplacement RIT clears a fault condition, the corresponding alarmsautomatically clears after a short delay. If the replaced board carries trafficthere will be a traffic reduction during the replacement.

    2.1.4 RestrictionsNone.

    14 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 2 G2 TC Transmission RITs

    2.2 Replace Transmission RITsThe following table lists the Transmission RITs.

    RIT Description

    ASMC Ater Submultiplexer Type C

    ATBX Alcatel-Lucent Branching and Switching

    DT16 Dual Rate Transcoder for 16 Channels

    JBFAN Fan Unit

    MT120 Multirate Transcoder with 120 channels

    MT120 WB New MT120 board which supports the AMR WB (AdaptiveMulti-Rate Wideband)

    MT120 NB New MT120 board in which supports the AMR (AdaptiveMulti-Rate Narrowband)

    Table 1: Transmission RITs

    To replace a transmission RIT:1. At the equipment site, locate the position of the faulty RIT.2. If appropriate, disconnect the front panel cables from the RIT, carefully

    noting their positions for re-connection.3. Connect the anti-static wrist strap.4. Unlock the retaining clips on the RIT.5. Carefully disengage the RIT from the backplane and fully withdraw it from

    the slot.

    Backplane DamageDo not use excessive force when inserting the RIT.

    6. Push the replacement RIT fully into the empty slot ensuring that pins andsockets are correctly aligned.

    7. Lock the retaining clips on the RIT.8. Disconnect the anti-static wrist strap.9. Replace any front panel connectors removed in Step 2 .

    10. Use the terminal to download the configuration data.11. Disconnect the terminal.12. Record the state of the LEDs on the replacement RIT when they are stable.13. Inform the 9153 OMC-R operator that the faulty RIT has been replaced,

    and report the state of the LEDs.

    3BK 21256 AAAA PCZZA Ed.10 15 / 38

  • 2 G2 TC Transmission RITs

    16 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    3 9125 TC RITs

    This chapter tells you how to replace 9125 TC RITs.It contains procedures for replacing the following RITs:

    MT120

    MT120 WB

    MT120 NB

    TCIF

    Fan cassettes.

    3BK 21256 AAAA PCZZA Ed.10 17 / 38

  • 3 9125 TC RITs

    3.1 Replace MT120In the 9125 TC rack there are only 9125 TC Transcoding Boards for Ater-E1(MT120).The 9125 TC is structured in four subracks, each containing up to twelveMT120.There are three types of MT120 boards: MT120 (legacy), MT120 WideBand(WB) and MT120 NarrowBand (NB).The following procedure applies for all types of MT120 boards.The part number of the MT120 board is:

    3BK 08882 xx for MT120 legacy

    3BK 27897 xx for MT120 WB

    3BK 28280 xx for MT120 NB.

    There are two means to perform a MT120 board replacement on the 9125TC rack:

    The first is by using the Replace Command on the TC NEM. This commandis used to ease the replacement procedure; the actions of the operator arelimited to the strict necessary. The only constraint is that the TC NEM mustbe able to retrieve the current configuration of the MT120 board to replace(this includes the SW version and the configuration parameters to run theMT120). For details see Replace a Board in 9125 TC NEM User Guide.The second means to replace the MT120 is needed when the TC NEMcannot retrieve the current configuration of the board to replace.

    3.1.1 Tools and MaterialsYou must have a TC NEM and an:

    RS-232 asynchronous communication link cable to connect it to a MT120legacy board (3BK 07951 AA)Ethernet crossed cable to connect it to a MT120 NB/WB board.

    Only one TC-NEM application should be connected to the TC rack at one time,regardless of the software management mode of the MT120 boards.If the MT120 boards are running in:

    TCIL management mode, only one TC-NEM can be connected (via MMIor Serial) to the TC rackHSI, management mode, only one TC-NEM can be connected (via IP)to the TC rack at a time.

    18 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    3.1.2 Impact on SystemAll telecommunications resources of the MT120 board to be replaced arelost during replacement procedure.

    In order to reduce the outage, make sure that the board used for replacement isloaded with the correct software version. If it is not the case, download therequired software version before starting the replacement.

    3BK 21256 AAAA PCZZA Ed.10 19 / 38

  • 3 9125 TC RITs

    3.1.3 Procedure 1

    Note: This procedure must be used when replacing a board by a similar one (MT120by MT120, MT120 WB by MT120 WB or MT120 NB by MT120 NB).

    3.1.3.1 MT120 in TCIL or no Direct Connection to the BoardTo replace a MT120 board using the Replacement Command:1. Unlock and open the front door of the TC rack.2. Connect the TC NEM to the TC rack; connection to any MT120 board with

    no autotest failure, indicated by a permanent red LED.3. Execute the MT120 board replacement command on TC NEM. For details

    see Replace a Board in 9125 TC NEM User Guide.

    Retrieve of DataIf the TC NEM can retrieve the current configuration of the MT120 board toreplace the command continues. Otherwise the operator must perform amanual replacement of theboard (see procedure 2).

    4. The operator must check that the PCM links of the MT120 he wants toremove carry no telecom traffic (indicated by the link connection statusDISCONNECTED on the display) (recommended).

    5. Unbolt the MT120 board. As there is no disable command, carefully extractthe MT120 board from the backplane and fully withdraw it from the slot.

    6. Replace it by a new one of the same type.

    Backplane DamageDo not use excessive force when inserting the new MT120 board.

    7. Follow the replacement procedure.8. After the new board is up and running, make sure that the [ Connect ] button

    of the TC-NEM is pressed in order to continue the procedure using theReplacement Wizard dialog box.

    9. At the TC NEM check the Qmux clusters and MT120 mapping.10. Set up the MT120 Remote Inventory (e.g. commissioning date, network

    identity, logical site name, etc.). For details see Modify the Remote Inventoryin 9125 TC NEM User Guide.

    11. Disconnect the TC NEM.12. Shut the front door of the TC rack and lock it.

    3.1.3.2 MT120 in HSI or MT120 in TCIL with Direct Connection to the BoardTo replace a MT120 board which is running in HSI management mode ( orMT120 in TCIL with direct connection available) :1. Unlock and open the front door of the TC rack.2. Using a direct connection (serial cable for MT120 legacy or Ethernet

    crossed cable for MT120 NB/WB board), physically connect to the board tobe replaced.

    3. Start the TC-NEM on serial (for MT120 legacy) or MMI (for MT120 NB/WB)connection.

    20 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    4. Execute the MT120 board replacement command on TC NEM. For detailssee Replace a Board in 9125 TC NEM User Guide.

    5. The operator must check that the PCM links of the MT120 he wants toremove carry no telecom traffic (indicated by the link connection statusDISCONNECTED on the display) (recommended).

    6. Unbolt the MT120 board. As there is no disable command, carefully extractthe MT120 board from the backplane and fully withdraw it from the slot.

    7. Replace it by a new one of the same type and follow the replacementprocedure.

    Backplane DamageDo not use excessive force when inserting the new MT120 board.

    8. If the new board is a MT120 NB/WB board you must:

    check its IP address

    configure TC NEM PC Ethernet network interface so as the IP addressof the TC NEM PC is in the same subnetwork with the IP address ofthe new MT120 NB/WB board

    start the TC-NEM on MMI connection using the IP address of the newMT120 NB/WB board.

    9. After the new board is up and running, make sure that the [ Connect ] buttonof the TC-NEM is pressed in order to continue the procedure using theReplacement Wizard dialog box.

    10. At the TC NEM check the Qmux clusters and MT120 mapping.

    Note: Even if the new board is running in TCIL mode and the old one was running inHSI mode, at the end of the replacement the new board will be running in HSIwithout any Change Mode command necessary.

    11. Set up the MT120 Remote Inventory (e.g. commissioning date, networkidentity, logical site name, etc.). For details see Modify the Remote Inventoryin 9125 TC NEM User Guide.

    12. Disconnect the TC NEM.13. Shut the front door of the TC rack and lock it.

    3BK 21256 AAAA PCZZA Ed.10 21 / 38

  • 3 9125 TC RITs

    3.1.4 Procedure 2

    Note: This procedure must be used when replacing a board by a different one (MT120by MT120 NB, MT120 by MT120 WB, MT120 WB by MT120, MT120 WB byMT120 NB, MT120 NB by MT120 or MT120 NB by MT120 WB).

    In case a MT120 legacy must be replaced by a MT120 NB/WB, before insertingthe MT120 NB/WB in the rack, all the MT120 legacy boards must be upgradedto the software version that will run on the MT120 NB/WB board.

    The following two cases describe how to replace manually a MT120 board:

    G2 TC and 9125 TC not equipped with STM1-IP subrack

    9125 TC rack equipped with STM1-IP subrack.

    3.1.4.1 Replace MT120 Board for G2 TC and 9125 TC not Equipped with STM1-IPSubrack

    To replace a MT120 board manually if the Replacement Command is notpossible:1. Unlock and open the front door of the TC rack.2. Connect the TC NEM to the TC rack, connection to any MT120 board with

    no autotest failure, indicated by a permanent red LED.For more information how to connect TC NEM to G2/9125 TC see Log On in9125 Transcoder NEM User Guide.

    3. Check that the PCM links of the MT120 that you want to remove carry notelecom traffic (indicated by the link connection status DISCONNECTED onthe display).

    4. Unbolt the MT120 board. As there is no disable command, carefully extractthe MT120 board from the backplane and fully withdraw it from the slot.

    5. If a MT120 board is replaced by a MT120-NB/WB board, before replacingthe MT120 board by a MT120-NB/WB board, all the MT120 boards in therack must be upgraded to the software version that will run also on theMT120-NB/WB. For details see Download Software via TCC and ActivateSoftware from TCC in 9125 Transcoder NEM User Guide.If a MT120-NB/WB board is replaced by a MT120 board, go to next step.

    6. Replace the faulty board by a new one.

    Backplane DamageDo not use excessive force when inserting the new MT120 board.

    7. Check software version of the replacement board. For details see View theSoftware Inventory in 9125 Transcoder NEM User Guide.

    8. If a MT120 board was replaced by a MT120-NB/WB board and if thesoftware version on the MT120-NB/WB is MTXBAX36.36A or older, or itis not up to date, download new software and activate it. For details seeDownload Software via TCC and Activate Software from TCC in 9125Transcoder NEM User Guide.If a MT120-NB/WB board was replaced by a MT120 board and if thesoftware version in not as requested, download new software and activate it.

    22 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    9. Set up the MT120 Remote Inventory (e.g. commissioning date, networkidentity, logical site name, etc.).

    10. Set up the fans/rack Remote Inventory.11. Configure the new MT120 for operational mode (i.e. enter for the new MT120

    the configuration parameters especially the BSC number and the Atermuxnumber for the Qmux cluster setting).

    12. If the new board is running in HSI mode, using a direct connection (serialcable for MT120 legacy or Ethernet crossed cable for MT120 NB/WB) ,change its management mode to TCIL.

    13. Disconnect the TC NEM.14. Shut the front door of the TC rack and lock it.15. Load configuration on MT120 board:

    from BSC TerminalTo load configuration on MT120 board from BSC Terminal see sectionLoad Configuration on MT120 Board from BSC Terminal (Section 3.1.4.3)from OMC-RTo load configuration on MT120 board OMC-R, see section LoadConfiguration on MT120 Board from OMC-R (Section 3.1.4.4).

    Note: To see immediately at OMC-R, in the "BSSUSM" window, the correct type ofthe new MT120 board you must trigger a BSC HW Audit. Otherwise, until anautomatic BSC HW audit will be triggered, the old MT120 board type willbe displayed.

    3.1.4.2 Replace MT120 Board in 9125 TC Equipped with STM1-IP SubrackTo replace an MT120 board manually if the Replacement Command is notpossible:1. Unlock and open the front door of the TC rack.2. Connect the TC NEM to the TC rack, connection to active TCIF board.

    For more information how to connect TC NEM to 9125 TC see Log On in9125 Transcoder NEM User Guide.

    3. Check that the PCM links of the MT120 that you want to remove carry notelecom traffic (indicated by the link connection status DISCONNECTED onthe display).

    4. Unbolt the MT120 board. As there is no disable command, carefully extractthe MT120 board from the backplane and fully withdraw it from the slot.

    5. If a MT120 board is replaced by a MT120-NB/WB board, before replacingthe MT120 board by a MT120-NB/WB board, all the MT120 boards in therack must be upgraded to the software version that will run also on theMT120-NB/WB. For details see Download Software via TCIF and ActivateSoftware from TCC in 9125 Transcoder NEM User Guide.If a MT120-NB/WB board is replaced by a MT120 board, go to next step.

    6. Replace the faulty board by a new one.

    Backplane DamageDo not use excessive force when inserting the new MT120 board.

    3BK 21256 AAAA PCZZA Ed.10 23 / 38

  • 3 9125 TC RITs

    7. If the new board is a MT120 NB/WB board you must:

    check its IP address

    configure TC NEM PC Ethernet network interface so as the IP addressof the TC NEM PC is in the same subnetwork with the IP address ofthe new MT120 NB/WB board

    start the TC-NEM on MMI connection using the IP address of the newMT120 NB/WB board.

    8. Check software version. For details see View the Software Inventory in9125 Transcoder NEM User Guide.

    9. If the software version is not up to date, download new software and activateit. For details see Download MT120 Software and Activate MT120 Softwarein 9125 Transcoder NEM User Guide.

    10. Set up the MT120 Remote Inventory (e.g. commissioning date, networkidentity, logical site name, etc.).

    11. Set up the fans/rack Remote Inventory.12. Configure the new MT120 for operational mode (i.e. enter for the new MT120

    the configuration parameters especially the BSC number and the Atermuxnumber for the Qmux cluster setting).

    13. If the new board is running in TCIL management mode, change itsmanagement mode to HSI.For more details see section Change Management Mode in document9125 Transcoder NEM User Guide.

    14. Disconnect the TC NEM.15. Shut the front door of the TC rack and lock it.16. Load configuration on MT120 board:

    from BSC TerminalTo load configuration on MT120 board from BSC Terminal see sectionLoad Configuration on MT120 Board from BSC Terminal (Section 3.1.4.3)from OMC-RTo load configuration on MT120 board OMC-R, see section LoadConfiguration on MT120 Board from OMC-R (Section 3.1.4.4).

    Note: To see immediately at OMC-R, in the "BSSUSM" window, the correct type ofthe new MT120 board you must trigger a BSC HW Audit. Otherwise, until anautomatic BSC HW audit will be triggered, the old MT120 board type willbe displayed.

    3.1.4.3 Load Configuration on MT120 Board from BSC TerminalTo load configuration on MT120 board from BSC Terminal follow this steps:1. From BSC terminal disable the appropriate SM_ADAPT. Follow the menu

    path:Commands -> Equipment Handling -> SBL Disable

    2. In the "SBL Disable" window enter:

    Object Class: SBLUnit Type: TC

    24 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    Unit Number: according to site configuration

    SBL Type: SM_ADAPT

    Nbr: according to SBL to be disabled

    WTC (Wait Traffic Clear): as requested3. Click on [ OK ].

    Wait for successful message to be displayed.4. From BSC terminal enable the appropriate SM_ADAPT. Follow the menu

    path:Commands -> Equipment Handling -> SBL Initialise

    5. In the "SBL Initialise" window enter:

    Object Class: SBLUnit Type: TC

    Unit Number: according to site configuration

    SBL Type: SM_ADAPT

    Nbr: according to SBL to be disabled

    WTC (Wait Traffic Clear): as requested6. Click on [ OK ].

    Wait for successful message to be displayed.

    3.1.4.4 Load Configuration on MT120 Board from OMC-RFollowing this steps to load configuration on MT120 board from OMC-R:1. Open "BSSUSM" from 9153 OMC-R.

    You have to know the rack number, the shelf and the slot in the self wherethe concerned MT120 board is located.

    2. In "BSSUSM : Main View" window, from "HW Equipment View right click onthe concerned MT120 board and Lock it.

    3. Wait for the board to lock and then right click on the board and Unlock.

    3BK 21256 AAAA PCZZA Ed.10 25 / 38

  • 3 9125 TC RITs

    3.2 Replace JBTCIFThe part number of the TCIF board is 3BK 27384 AAxx.

    3.2.1 Tools and MaterialsThe following items must be available before starting the replacementprocedure:

    TC-NEM software

    Putty software

    Ethernet straight cable

    Ethernet crossed cable

    DB9 to RJ45 adapter (JADB9RJ), with part number 3BK 27547 AAAA forthe serial connection to the TCIFs front panel on the RS port.

    3.2.2 Impact on SystemNone.

    3.2.3 Procedure

    3.2.3.1 Check the Status of the Active TCIF BoardTo check the status of the active TCIF board:1. Open a putty session, on the active TCIF board:

    Launch putty.exeA PuTTY Configuration window opens

    In the Protocol area select

    Complete the Host Name (or IP address) field with TCIF IP addresswhere:

    x is 1 for TCIF1x is 2 for TCIF2

    Help: The TCIF IP address is the IP address given at TC NEM, in the "IPConf" window.

    Click on [ Open ] to start sessionPress [ Yes ] to close the "Security Alert" window, if it is the case.

    2. Type the username:HDEV

    and the password:cit_ln

    3. Change to super user, by typing:su

    4. When prompted for the password, type:tcif

    26 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    5. Type the following command in order to check the processes:ps ef | grep tcif

    An example of the output is given below:/opt0/tcifR-1.1/bin/hsid -C/opt0/tcifR-1.1/share/tcif/hsid.conf -i192.168.120.129/opt0/tcifR-1.1/bin/saed -C/opt0/tcifR-1.1/share/tcif/saed.conf/opt0/tcifR-1.1/bin/oaed -C/opt0/tcifR-1.1/share/tcif/oaed.conf/opt0/tcifR-1.1/bin/mmirelay -C/opt0/tcifR-1.1/share/tcif/mmirelay.conf -i0.0.0.0/opt0/tcifR-1.1/bin/qmux_forwarder -C/opt0/tcifR-1.1/share/tcif/qmuxforwarder.conf/opt0/tcifR-1.1/sbin/in.tftpd -dd -l -s/mnt/flash/distfiles/MT120SW/grep tcif

    3.2.3.2 Check the Firmware Version of the STM-1 Daughter Board on the Active TCIFTo check the firmware version of the STM-1 daughter board:1. Make sure that the putty connection on the active TCIF board established

    during Check the Status of the Active TCIF Board (Section 3.2.3.1) isstill available.

    2. Check the firmware version of the STM-1 daughter board on the active TCIF:cd /opt/tcifR-1.1/bin./TestOBCDrv.test Test_OBC_Drv test_ReadStm1Version2>/dev/null

    The output of the command is like following:Running 1 testArchVersion: 1 TestVersion:

    The version number of the firmware is given by this .Write it down, because it will be needed later, when comparing the firmwareversion with the one on the new TCIF board.

    3BK 21256 AAAA PCZZA Ed.10 27 / 38

  • 3 9125 TC RITs

    3.2.3.3 Remove the Faulty BoardTo remove the faulty board:1. Unplug the normal (straight) Ethernet cable from the back panel,

    corresponding to the faulty (standby) TCIF:If TCIF 1 (Slot 0) is faulty: RJ2-0 or/and RJ1-0If TCIF 2 (Slot 1) is faulty: RJ2-1 or/and RJ1-1

    2. If the faulty (standby) TCIF board can be locked from TC-NEM:From TC-NEM lock the standby board.Wait until this board becomes red in TC NEM "Rack Overview" window.

    Unplug the optical fiber connectors and remove the faulty board fromthe subrack

    Insert the new board in the same slot

    Power ON the new board (push the metallic lever on the right side).The blue LED switches OFF.Wait for about 8 minutes in order for this new board to power up.

    Open a serial connection to this new board:Connect the DB9 to RJ45 adapter and Ethernet (straight) cablebetween the COMx port of the PC and the RS port on the TCIFfront panel.Start the HyperTerminal (or TeraTerm). Follow the menu path:Start -> Programs -> Accessories -> Communications ->HyperTerminalThe "Connection Description" window opens.In the "Connection Description" window enter a name and select anicon for the connection, then click on [ OK ].The "Connect to" window opens.In the "Connect to" window select the used serial port, then click on[ OK ].The "COMx Properties" window opens.In the "COMx Properties" window enter:

    Bits per second: 115200

    Data bits: 8

    Parity: None

    Stop bits: 1

    Flow control: None

    Click on [ Apply ] then on [ OK ]In the HyperTerminal (or TeraTerm) window click on [ Enter ] andlogin as:Username: rootPassword: tcif

    28 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    If the new board has been installed before, you must clean it. See Cleanthe New Board (Section 3.2.3.4)Remove the serial cable from the RS port.

    3. If the faulty (standby) TCIF board can not be locked from TC-NEM:Remove the faulty board from the subrack

    Insert the new board in the same slot

    Power ON the new board (push the metallic lever on the right side)The blue LED switches OFF.Wait for about 8 minutes in order for this new board to power up.

    Establish the serial connection to the RS port on the front panel of thenew TCIF board, using the HyperTerminal (or Tera Term)See Step 2 from Remove the Faulty Board (Section 3.2.3.3).If the new board has been installed before, you must clean it. See Cleanthe New Board (Section 3.2.3.4)Remove the serial cable from the RS port

    From TC-NEM lock the new board.This board will become red in TC NEM "Rack Overview" window.

    3BK 21256 AAAA PCZZA Ed.10 29 / 38

  • 3 9125 TC RITs

    3.2.3.4 Clean the New BoardThis procedure applies if the new TCIF board has been installed before andhas some old processes running on it.To clean the board:

    Stop the heartbeat process:/opt/heartbeat-2.1.2/init.d/heartbeat stop

    When the heartbeat process is stopped, there will be no other processrunning (hsid, saed, oaed, mmirelay, qmux_forwarder, and in.tftpd areautomatically stopped).Check if the logd is present:

    /opt/tcifR-1.1/init.d/logd status

    Stop the logd process, if present:/opt/tcifR-1.1/init.d/logd stop

    Check that all other processes are stopped also:ps eaf | grep tcif

    Delete files:cd /mnt/flash/rm rf *rm rf .snmprm rf .net-snmp

    Check there is no file in /mnt/flash directory:ls -altr /mnt/flash

    Check there is no application installed and running:ps eaf

    Reboot the TCIF board by typing:reboot

    Make sure that the serial connection to the RS port on the front panel of theTCIF board is removed.Wait for about 8 minutes until the reboot is finished.

    30 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    3.2.4 Install the New BoardTo install the new board:1. Connect the Ethernet crossed cable between the ETH connectors on the

    front panel of the two TCIF boards.2. Establish again the serial connectin on the new TCIF board.

    See Step 2 from Remove the Faulty Board (Section 3.2.3.3).3. On the serial connection to the new board, enter:

    dhcpcd eth2chown HDEV -R /mnt/flashchown HDEV -R /usr/libchown HDEV /dev/mtd1

    4. Write down the new board eth2_ip address, it will be used later on duringthe procedure.

    This new board eth2_ip address must be from the same subnetwork as the onegiven in TC-NEM in the "IP Conf" window in Internal IP Network Address field.

    5. If this is not the case, perform a reboot of the new board, by typing:reboot

    Make sure that the serial connection to the RS port on the front panel of theTCIF board is removed.Wait for about 8 minutes so the board is up again and re-establish theserial connection.Enter the commands from step 3 and check that the new board eth2_ipaddress is in the same subnetwork with the Internal IP Network Address.

    6. Remove the serial cable from the new board.

    Make sure that no serial cable is connected on the front panel of the activeTCIF board.

    7. Open a putty session, on the active TCIF board:

    Launch putty.exeA PuTTY Configuration window opens

    In the Protocol area select

    Complete the Host Name (or IP address) field with TCIF IP addresswhere:

    x is 1 for TCIF1x is 2 for TCIF2

    Help: The TCIF IP address is the IP address given at TC NEM, in the "IPConf" window.

    Click on [ Open ] to start sessionPress [ Yes ] to close the "Security Alert" window, if it is the case.

    3BK 21256 AAAA PCZZA Ed.10 31 / 38

  • 3 9125 TC RITs

    8. Type the username:HDEV

    and the password:cit_ln

    9. Change to super user, by typing:su

    10. When prompted for the password, type:tcif

    11. Check that the connectivity to the new board using the cross cable isestablished:

    ping < new_board_eth2_ip >In this case is the one noted during step 3.

    12. Launch the board replacement script with the new_board_eth2_ip givenas argument:

    /opt/tcifR-1.1/scripts/board_repl.shnew_board_eth2_ip

    This procedure takes about 40 minutes.When the board replacement script is finished, the active TCIF board willautomatically trigger the reboot of the new board.The reboot starts only when Reset standby board and Reset donemessages appear.Wait about 8 minutes for the board to be up and running.

    13. Plug in the RS cable back in the new board.The login message is available on the serial connection.

    14. Log in as:Username: rootPassword: tcif

    15. On serial connection check that the processes are up. See Step 5 fromCheck the Status of the Active TCIF Board (Section 3.2.3.1).The starting of the processes will take about 5 minutes.

    16. On serial connection check the firmware version on the STM-1 daughterboard of the new TCIF board. See Check the Firmware Version of theSTM-1 Daughter Board on the Active TCIF (Section 3.2.3.2) for details.

    17. Remove the Ethernet crossed cable connected between the ETH2 connectorof the two TCIF boards.

    18. Plug the Ethernet (straight) cable at the back panel, to connectorscorresponding to the replaced TCIF board.

    19. Unplug the RS cable from the front panel.

    Be sure, that on the front panel no RS cables remains connected.

    32 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    20. If the firmware version of the STM-1 daughter board is:

    older that the one running on the other (active)TCIF board:perform the upgrade of the firmware of the STM-1 daughter board,according to Upgrade the STM-1 Daughter Board (Section 3.2.5)plug the optical fiber connectors on the new TCIF board according totheir old position.from TC-NEM unlock the new TCIF board.The board will become black in TC NEM "Rack Overview" window.

    the same or newer than the one running on the other (active) TCIFboard:

    plug the optical fiber connectors on the new TCIF board according totheir old position.from TC-NEM unlock the new TCIF board.The board will become black in TC NEM "Rack Overview" window.

    For example, if the firmware version of the new TCIF board is:

    e, then the upgrade to f or 10 must be performed (depending on theversion present on the active TCIF board)f or 10, then no upgrade is necessary.

    3.2.5 Upgrade the STM-1 Daughter BoardTo upgrade the STM-1 daughter board:1. Open a putty session, on the standby TCIF board:

    Launch putty.exeA PuTTY Configuration window opens

    In the Protocol area select

    Complete the Host Name (or IP address) field with TCIF IP addresswhere:

    x is 1 for TCIF1x is 2 for TCIF2

    Help: The TCIF IP address is the IP address given at TC NEM, in the "IPConf" window.

    Click on [ Open ] to start sessionPress [ Yes ] to close the "Security Alert" window, if it is the case.

    2. Type the username:HDEV

    and the password:cit_ln

    3. Change to super user, by typing:su

    4. When prompted for the password, type:

    3BK 21256 AAAA PCZZA Ed.10 33 / 38

  • 3 9125 TC RITs

    tcif

    Note: It is recommended that you save a log file of the output from putty.5. Stop the heatbeat process:

    /opt/heartbeat-2.1.2/init.d/heartbeat stop6. Stop the logd process:

    /opt/tcifR-1.1/init.d/logd stop7. Check that the other processes are also stopped:

    ps ef | grep tcifThe output should be:

    root 23432 18590 0 00:31 ttyp0 00:00:00 grep tcif

    8. Upgrade the STM-1 daughter board.cd /opt/tcifR-1.1/bininsmod/lib/modules/2.6.10_mvlcge401-8560ads/jts10_jtag_drv.kocat /proc/devices | grep jtag

    The command will return the major value for the driver jts10_jtag_drv: jtag_drv

    9. Use this value in the next command:mknod /dev/jtag_drv c 0cd /fpgajts10_jtag_loader Firecron_infra_Ip1.bvf

    If the upgrade implies that the to be reached is 10 then in the step9 mentioned above the second comand will be:

    cd /opt/tcifR-1.1/lib/fpga

    The answer on the display should be (the values in the report can bedifferent):

    JTAG JGTCBM management : Mar 18 2008-13:36:26release 01.01Loading file : Firecron_infra_lp1.bvf...

    Report:-> Total Byte Number: 452-> Number of Test: 232-> Number of Error: 0-> Number of Success: 232Load OK !!!!

    If the result of the file Firecron_infra_lp1.bvf is Load Failed !!!!, try to rebootthe TCIF board. If the TCIF doesnt come up after reboot, contact theAlcatel-Lucent Support.

    34 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    10. Load the new software:jts10_jtag_loader

    The value of is:

    tcbm_v1t15.bvf for an upgrade from version e or earlier versions to fversion

    tcbm_v1t16.bvf for an upgrade from version e, or f to 10 version.

    The answer on the display should be:JTAG JGTCBM management : Mar 18 2008-13:36:26release 01.01Loading file : tcbm_v1t15.bvf.....

    Report:-> Total Byte Number: 747897-> Number of Test: 272008-> Number of Error: 0-> Number of Success: 272008Load OK !!!!

    It takes some tens of seconds to be loaded.11. Reboot the TCIF by typing:

    rebootWait until the reboot is finished.

    12. Open a putty session and check that the processes are up, see sectionCheck the Status of the Active TCIF Board (Section 3.2.3.1).

    3BK 21256 AAAA PCZZA Ed.10 35 / 38

  • 3 9125 TC RITs

    3.3 Replace FANU for MT120 BoardsThere are three fan cassettes (including two fans each) below each MT120subrack. The reference number of this 9125 TC Cooling Fan Stage (FANU)is: 3BK 30802 AA.

    3.3.1 Tools and MaterialsYou must have a TC NEM and an RS-232 asynchronous communication linkcable to connect it to an MT120 board.

    3.3.2 Impact on SystemThe FANU can be replaced by hot-swapping (no power supply switched off),and there is no loss of telecommunications resources.

    3.3.3 ProcedureTo replace a FANU:1. Unlock and open the front door of the TC rack2. Connect the TC NEM to the TC rack3. Start the program of the TC NEM; use the TCC window to locate the

    defective fan cassette.4. Unbolt the latch at the front to release the FANU, and then pull it out from

    the backplanel and fully withdraw it from the slot.Replace it by a new one. Check that the latch snaps into the locked position.

    Backplane DamageDo not use excessive force when inserting the new fan cassette.

    5. Use the TCC window at the TC NEM to check that all fans are workingproperly.

    Measurement IntervalWhen checking the fan status the temperature measurement interval hasto be taken into account.

    6. Disconnect the TC NEM.7. Shut the front door of the TC rack and lock it.

    36 / 38 3BK 21256 AAAA PCZZA Ed.10

  • 3 9125 TC RITs

    3.4 Replace FANU for TCIF BoardsThere are two fan cassettes (including two fans each) placed one on the leftand one on the right side of the TCIF subrack. The reference number of this9125 TC Cooling Fan Stage (FANU) is: 3BK 30802 AA.

    3.4.1 Tools and MaterialsYou must have a TC NEM and an Ethernet crossed cable connected toa TCIF board.

    3.4.2 Impact on SystemThe FANU can be replaced by hot-swapping (no power supply switched off),and there is no loss of telecommunications resources.

    3.4.3 ProcedureTo replace a FANU:1. Unlock and open the front door of the TC rack.2. Connect the TC NEM to the TC rack.3. Start the program of the TC NEM; use the TCIF window to locate the

    defective fan cassette.4. Unbolt the latch at the front to release the FANU, and then pull it out from

    the backpanel and fully withdraw it from the slot.Replace it by a new one. Check that the latch snaps into the locked position.

    Backplane DamageDo not use excessive force when inserting the new fan cassette.

    5. Use the TCIF window at the TC NEM to check that all fans are workingproperly.

    Measurement IntervalWhen checking the fan status the temperature measurement interval hasto be taken into account.

    6. Disconnect the TC NEM.7. Shut the front door of the TC rack and lock it.