Tap-Changer VUCGRN · 2021. 2. 16. · 60 $ 60 $ 30 $ 86 41 100 45 $ 45 $22,5 45 $ 22 26 10 11...

2
This document is issued by means of a computerized syste The digitally stored original is ele ctronically approved approved document has a date entered in the `Approved'-f A manual signature is not required. The information contained in this document has to kept strictly confidential. Any unautorized use, reproduction, distribution or disclosure to third parties are strictly forbidden. ABB reservs all rights regarding Intellectual Property Rights. © Copyright 2010 ABB. All rights reserved. 6917 028-PA(A4)Rev1 255 27 30 50 D 470 600 111 205 C 740 710 220 220 98 6 289 110 959 A B 45 39 80 C/L Top flange 332 60 30 C/L Diverter switch 24x 15 E 110 110 F 55 F 110 110 55 55 C/L Tap selector (2) 1ZSC004163-ABA No. Shts. Document no. 1 16-35 Pos A Sheet no. Order Revision 82 XXXX/450-600/C 2012-04-02 Henrik Sundberg Language Used in product Approved by Tap-Changer VUCGRN 2012-03-01 Tomas Axelsson Take over department Modified by PPCO/TK 2011-11-29 Tomas Axelsson Title Responsible department Prepared INSULATION380 1050 SHORT VERSION b) LEVEL kV 650 380,650 750 750 1050 A2151 a)2451 a)1931 a)2231 a) Dimen- sions in mm B 1192 a)1492 a)972 a)1272 a) C 119 a)c) 119 a) 119 a)c) 119 a) D 240 c) 540 240 c) 540 Positions E F 16-27 18 37 28-35 56 56 14 (Diverter switch terminal) a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1) b) Short version means reduced switching capac Please refer to Technical Guide c) Not applicable for 380 kV Transformer flange 650 Contact 5 at 16-23 pos. Contact 7 at 24-31 pos. Contact 9 at 32-35 pos. H-2,4..18 V-1,3..17 V-1,3..17 H-2,4..18 H-2,4..18 20 21,22 V-1,3..17 Same potential as the diverter switch terminal Shielding rings for insulation levels 650, 750 and 1050 only Only for insulation level 1050 kV 21,22 21,22 20 20

Transcript of Tap-Changer VUCGRN · 2021. 2. 16. · 60 $ 60 $ 30 $ 86 41 100 45 $ 45 $22,5 45 $ 22 26 10 11...

Page 1: Tap-Changer VUCGRN · 2021. 2. 16. · 60 $ 60 $ 30 $ 86 41 100 45 $ 45 $22,5 45 $ 22 26 10 11 1ZSC004163-ABA (2) Document no. No. Shts. A 16-35 Pos 2 Revision Order Sheet no. Henrik

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

255

27

30

50

D

470

600

111 205

C

740

710

220 220

98

6

289

110

959

A

B

4539

80 C/L Top flange

332

60

30 C/L Diverter switch

24x 15

E

110

110

F

55

F

110

110

55

55

C/L Tap selector

(2)1ZSC004163-ABANo. Shts.Document no.

116-35 PosA

Sheet no.OrderRevision

82 XXXX/450-600/C2012-04-02Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer VUCGRN2012-03-01Tomas Axelsson

Take over departmentModified by

PPCO/TK2011-11-29Tomas Axelsson

TitleResponsible departmentPrepared

INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650

750 750 1050

A 2151 a)2451 a)1931 a)2231 a)Dimen-sionsin mm

B 1192 a)1492 a)972 a) 1272 a)

C 119 a)c)119 a) 119 a)c)119 a)

D 240 c) 540 240 c) 540

Positions E F

16-27 18 37

28-35 56 56

14 (Diverter switch terminal)

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity.Please refer to Technical Guidec) Not applicable for 380 kV

Transformer flange650

Contact 5 at 16-23 pos.Contact 7 at 24-31 pos.Contact 9 at 32-35 pos.

H-2,4..18

V-1,3..17

V-1,3..17

H-2,4..18

H-2,4..18

20 21,22

V-1,3..17

Same potential as thediverter switch terminal

Shielding rings forinsulation levels 650,750 and 1050 only

Only for insulation level 1050 kV

21,22

21,22

20

20

Page 2: Tap-Changer VUCGRN · 2021. 2. 16. · 60 $ 60 $ 30 $ 86 41 100 45 $ 45 $22,5 45 $ 22 26 10 11 1ZSC004163-ABA (2) Document no. No. Shts. A 16-35 Pos 2 Revision Order Sheet no. Henrik

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

36�$

72�$

36�$

25,7�$

25,7�$

51,5�$

25,7�$

20�$

20�$

40�$

20�$

86

41

20�$

100

R200

232

41

86 84�$

48�$

R200

60�$

60�$

30�$

86

41

100

45�$

45�$ 22,5�$

45�$

22

26

10

11

(2)1ZSC004163-ABANo. Shts.Document no.

216-35 PosA

Sheet no.OrderRevision

82 XXXX/450-600/C2012-04-02Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer VUCGRN2012-03-01Tomas Axelsson

Take over departmentModified by

PPCO/TK2011-11-29Tomas Axelsson

TitleResponsible departmentPrepared

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL:54830001-1Motor Drive BUE:54830001-2 or -3External Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1

T=9

16-19 positions

P-P

836

1

49 2

7

5

Current collector

Current collector

2010

22

21

P-P

24-27 positions

81

103

294

11

613

125

7

2014

22

21

P-P

32-35 positions

123

145

167

211

413

615

101

817 9

2018

22

21

A

20-23 positions

P-P

611

81

103

2012

22

215

27

49

P-P

28-31 positions

101

815

613 4

11

29

721

22

201614

5

123

A