Tabel Calcul Termic STAS 1907

21
Setari generale ( pt. intregul imobil ) : Zona climatica II -15 Zona eoliana II in localitate 5.0 Adincimea pinzei de apa freatica 7.00 Coef. Etaj E 1.000 1.00 denumire / destinatie camera °C 20 Wh 0 Wh/mc 0.00 Wh/mp 0.00 L h Rc Wh H sol L h Rc Wh H sol l aprox. exact fer./us l aprox. exact fer./us perete 1 2.50 0.00 0.00 M -15 0.00 0.00 1.038 perete 2 2.50 0.00 0.00 M -15 0.00 0.00 1.038 fereastra 1 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 1 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 2 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 2 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 3 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 3 0.00 0.00 T. Slab -15 0.00 0.094 1.200 usa 0.00 0.00 T. Slab -15 0.00 0.094 1.200 usa 0.00 0.00 T. Slab -15 0.00 0.094 1.200 perete 3 2.50 0.00 0.00 M -15 0.00 0.00 1.038 perete 4 2.50 0.00 0.00 M -15 0.00 0.00 1.038 fereastra 1 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 1 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 2 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 2 0.00 0.00 T. Slab -15 0.00 0.094 1.200 usa 0.00 0.00 T. Slab -15 0.00 0.094 1.200 usa 0.00 0.00 T. Slab -15 0.00 0.094 1.200 perete 5 2.50 0.00 0.00 M -15 0.00 0.00 1.038 perete 6 2.50 0.00 0.00 M -15 0.00 0.00 1.038 fereastra 0.00 0.00 T. Slab -15 0.00 0.094 1.200 fereastra 0.00 0.00 T. Slab -15 0.00 0.094 1.200 usa 0.00 0.00 T. Slab -15 0.00 0.094 1.200 usa 0.00 0.00 T. Slab -15 0.00 0.094 1.200 perete 7 2.50 0.00 0.00 S 0.70 20 0.00 1.000 perete 8 2.50 0.00 0.00 S 0.70 20 0.00 1.000 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 perete 9 2.50 0.00 0.00 S 0.70 18 0.00 1.000 perete 10 2.50 0.00 0.00 S 0.70 20 0.00 1.000 usa 0.00 0.00 T. Slab 18 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 18 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 perete 11 2.50 0.00 0.00 S 0.70 20 0.00 1.000 perete 12 2.50 0.00 0.00 S 0.70 20 0.00 1.000 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 perete 13 2.50 0.00 0.00 S 0.70 20 0.00 1.000 perete 14 2.50 0.00 0.00 S 0.70 20 0.00 1.000 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 usa 0.00 0.00 T. Slab 20 0.00 0.094 1.200 podea 1 0.00 0.00 P1 20 0.00 0.00 1.000 tavan 1 0.00 0.00 0.00 0.00 T1 20 0.00 0.00 1.038 podea 2 0.00 P1 20 0.00 0.00 1.000 tavan 2 0.00 0.00 0.00 0.00 T1 20 0.00 1.038 podea 3 0.00 P1 20 0.00 0.00 1.000 tavan 3 0.00 0.00 0.00 0.00 T1 20 0.00 1.038 podea 4 0.00 P1 20 0.00 0.00 1.000 tavan 4 0.00 0.00 0.00 0.00 T1 20 0.00 1.038 podea 5 0.00 P1 20 0.00 0.00 1.000 tavan 5 0.00 0.00 0.00 0.00 T1 20 0.00 1.038 fereastra 1 0.00 0.00 T. Slab -15 0.00 0.094 1.200 1 fereastra 2 0.00 0.00 T. Slab -15 0.00 0.094 1.200 1 Punct Cardinal Est 0.00 1.20 0.00 0 V - volumul camerei 0.00 0.000 0.00 0.50 0 0.60 0.00 1.40 0 0.00 0.00 16.200 0.00 8.55 1.20 0 Adaosuri 1.162 0.000 destinatie camera 0.00022 1,011 0 0.000 camere de locuit 0 CM T inter. Necesar termic total denumire element construct ie Supra f Total a calcu l / ext. a peret . m elem. de constr. denumire element construct ie Supra f Total a calcu l / ext. a peret . m elem. de constr. Lvitral. Lvitral. Aveti mai jos o serie de marimi si valorile lor, conform SR 1907, asa cum le utilizeaza si acest program. O parte provin din pag. Culise, o parte sint rezultatul unor formule de calcul, iar o alta parte sint constante ce pot fi introduse de operator. Atentie sa nu stergeti din greseala vreo formula. Cei care au cunostinte in domeniu isi pot adapta si mai bine calculele la experienta si nevoile lor, ca si in pagina Culise. Iar cei care se pricep mai putin, aveti grija ce date introduceti aici ! Modificati DOAR daca : 1. sinteti sigur pe ceea ce faceti, sau 2. doriti doar sa vedeti cum afecteaza modificarea unei valori rezultatul final, dupa care dati un "UNDO" = Ctrl+Z. AT λ mediu A usi ext. Qi1 Ao Ap ms n-nr.desch. Qi2 Rm Rp ns Qu L rosturi QS Ac Abc V 3/4 ρ aer QT R bc pt. nao nao Cp QT*adaosuri Abcj QT*ad.+Qi

description

Tabel Calcul Termic STAS 1907.xls

Transcript of Tabel Calcul Termic STAS 1907

Radia3-PVK

CameraSetari generale ( pt. intregul imobil ) :Zona climaticaII-15Zona eolianaIIin localitate5.0Adincimea pinzei de apa freatica7.00Coef. Etaj E1.000CM1.00012/31/99denumire / destinatie cameraT inter.C20Necesar termic totalWh0Wh/mc0.00Wh/mp0.00denumire element constructieLhSupraf TotalaS de calcul / LRcTemp ext. a peret.WhH solm elem. de constr.denumire element constructieLhSupraf TotalaS de calcul / LRcTemp ext. a peret.WhH solm elem. de constr.lLvitral.aprox.exacti fer./usilLvitral.aprox.exacti fer./usiperete 12.500.000.00M-150.000.001.038perete 22.500.000.00M0.00-150.000.001.038VALIDARIZonafereastra 10.000.00T. Slab-150.000.0941.200fereastra 10.000.00T. Slab-150.000.0941.200Temp.IzolatiePunctIzolatieIzolatieIzolatieclimaticaAmplasarefereastra 20.000.00T. Slab-150.000.0941.200fereastra 20.000.00T. Slab-150.000.0941.200cam. Cpereti ext.cardinalGEAMPodeaTavaneolianacladirefereastra 30.000.00T. Slab-150.000.0941.200fereastra 30.000.00T. Slab-150.000.0941.2006FSNordG.SimpluP1T1Iin localitateusa0.000.00T. Slab-150.000.0941.200usa0.000.00T. Slab-150.000.0941.20010SN - EG.Dublu1P2T2IIinafara localit.12S-MN - VG.Dublu2P3T3IIIperete 32.500.000.00M-150.000.001.038perete 42.500.000.00M0.00-150.000.001.03815MEstT. SlabP4T4IVdestinatie camerafereastra 10.000.00T. Slab-150.000.0941.200fereastra 10.000.00T. Slab-150.000.0941.20018M-BVestT. BunP5T5camere de locuitfereastra 20.000.00T. Slab-150.000.0941.200fereastra 20.000.00T. Slab-150.000.0941.20020BS - ET.f. BunP6T6bucatariiusa0.000.00T. Slab-150.000.0941.200usa0.000.00T. Slab-150.000.0941.20022FBS - VP7T7bai24Sudperete 52.500.000.00M-150.000.001.038perete 62.500.000.00M0.00-150.000.001.038fereastra0.000.00T. Slab-150.000.0941.200fereastra0.000.00T. Slab-150.000.0941.200sumaGEAMA peretepentrusumaGEAMA peretepentruusa0.000.00T. Slab-150.000.0941.200usa0.000.00T. Slab-150.000.0941.200QTi * Lsub solAbcRper. solQTi * Lsub solAbcRper. solAbcjAbcjperete 72.500.000.00S0.70200.001.000perete 82.500.000.00S0.70200.001.000perete 10.0000.000.000.00perete 20.0000.000.000.00usa0.000.00T. Slab200.000.0941.200usa0.000.00T. Slab200.000.0941.200perete 30.0000.000.000.00perete 40.0000.000.000.00usa0.000.00T. Slab200.000.0941.200usa0.000.00T. Slab200.000.0941.200perete 50.0000.000.000.00perete 60.0000.000.000.00perete 70.000.000.00perete 80.000.000.00perete 92.500.000.00S0.70180.001.000perete 102.500.000.00S0.70200.001.000perete 90.000.00perete 100.000.00usa0.000.00T. Slab180.000.0941.200usa0.000.00T. Slab200.000.0941.200perete 110.000.00perete 120.000.00usa0.000.00T. Slab180.000.0941.200usa0.000.00T. Slab200.000.0941.200perete 130.000.00perete 140.000.000.000.0000.000.00m. ponder.0.000.000.000.00m. ponder.perete 112.500.000.00S0.70200.001.000perete 122.500.000.00S0.70200.001.0000.0000.000.00usa0.000.00T. Slab200.000.0941.200usa0.000.00T. Slab200.000.0941.2000.00perete 132.500.000.00S0.70200.001.000perete 142.500.000.00S0.70200.001.000usa0.000.00T. Slab200.000.0941.200usa0.000.00T. Slab200.000.0941.200radical din Appt. A pRp solRbc solS O L !podea 10.000.00P1200.000.001.000tavan 10.000.000.000.00T1200.000.001.038podea 10.000.000.000.00001 Qs0.00podea 20.00P1200.000.001.000tavan 20.000.000.000.00T1200.001.038podea 20.000.000.000.00002 Qs0.00podea 30.00P1200.000.001.000tavan 30.000.000.000.00T1200.001.038podea 30.000.000.000.00003 Qs0.00podea 40.00P1200.000.001.000tavan 40.000.000.000.00T1200.001.038podea 40.000.000.000.0000podea 50.00P1200.000.001.000tavan 50.000.000.000.00T1200.001.038podea 50.000.000.000.0000Temp ej18fereastra 10.000.00T. Slab-150.000.0941.20010.000.000.000.000pt. Rm0.00fereastra 20.000.00T. Slab-150.000.0941.20012.95media ponderatadupa suprafeteAveti mai jos o serie de marimi si valorile lor, conform SR 1907, asa cum le utilizeaza si acest program. O parte provin din pag. Culise, o parte sint rezultatul unor formule de calcul, iar o alta parte sint constante ce pot fi introduse de operator. Atentie sa nu stergeti din greseala vreo formula. Cei care au cunostinte in domeniu isi pot adapta si mai bine calculele la experienta si nevoile lor, ca si in pagina Culise. Iar cei care se pricep mai putin, aveti grija ce date introduceti aici ! Modificati DOAR daca : 1. sinteti sigur pe ceea ce faceti, sau 2. doriti doar sa vedeti cum afecteaza modificarea unei valori rezultatul final, dupa care dati un "UNDO" = Ctrl+Z.Punct CardinalEstAT0.00 mediu1.20A usi ext.0.00Qi10V - volumul camerei0.00Ao0.000Ap0.00ms0.50n-nr.desch.Qi20Rm0.60Rp0.00ns1.40Qu0L rosturi0.00QS0.00Ac16.200Abc0.00V 3/48.55 aer1.20QT0Adaosuri1.162R bc0.000pt. naodestinatie cameranao0.00022Cp1,011QT*adaosuri0Abcj0.000camere de locuitQT*ad.+Qi0

&LNume Client : . . . . . . . . . . . . . . . . . . . . . .&C&14TOTAL&R&DAurel : In celula din dreapta ( G2 ) se alege zona climatica in care este amplasat imobilul, conform hartii cu zonarea climatica a Romaniei. O astfel de harta poate fi gasita pe blog sau chiar in acest fisier, in pagina Culise. Astfel se alege temperatura exterioara ( de afara ) cu care se fac calculele.Aurel : Aici se alege zona climatica in care este amplasat imobilul. Se alege una dintre cele 4 zone de temperaturi medii pe timp de iarna, in care este impartita Romania. O harta a impartirii Romaniei pe zone climatice poate fi gasita pe blog sau in acest fisier, in pag. Culise.Aurel:Se afiseaza temperatura de afara, exterioara, conform zonei climatice alese.Zona 1 = - 12 grade C.Zona 2 = - 15 grade C.Zona 3 = - 18 grade C.Zona 4 = - 21 grade C.Aurel : In celula din dreapta ( J1 ) se alege zona eoliana in care se incadreaza locatia imobilului, conform hartii cu zonarea eoliana a Romaniei. Astfel se alege viteza conventionala de calcul a vintului, cu care se fac calculele ( vezi si celula de dedesubt ).O astfel de harta gasiti pe blog sau in acest fisier, in pag. Culise.Aurel : Aici se alege zona eoliana in care este amplasat imobilul. Se poate opta pt. una dintre cele 4 zone eoliene in care este impartita Romania.Aurel:Se alege intre cele 2 situatii : imobilul se afla in localitate sau inafara localitatii.Aurel:Se afiseaza automat viteza conventionala de calcul a vintului, in functie de zona eoliana si de amplasamentul cladirii in localitate sau inafara ei.Aurel: Adincimea pinzei de apa freatica ( in metri ).E necesara pt. calculul Qs = caldura pierduta prin sol. Nu se ia in calcul decit daca in cel. I9 am ales valoarea P6 sau P7, respectiv daca podeaua incaperii este asezata pe sol sau sub nivelul solului. Daca nu o cunoasteti, pt. cazul dvs. concret, alegeti valoarea 7.Aurel: Aici introducem valoarea lui CM = coeficientul de corectie al necesarului de caldura de calcul, in functie de masa specifica a elementelor de constructie interioare ale constructiei. Poate avea valorile de 1 sau 0,94.Aurel:Coeficient pt. Abc, la radicalul din Ap-uri.Aurel:Aici se alege temperatura de calcul dorita IN incapere.Se poate scrie orice valoare.Influenteaza in mare masura pierderile de caldura.Aurel:Wh = Watt - ora.Aceasta este de fapt unitatea de masura a energiei termice = caldurii furnizate intr-o incapere sau pierdute de o incapere. De cele mai multe ori, se omite h-ul (ora) si se asimileaza cu Watt.Aurel:Aici se afiseaza automat suma totala a pierderilor si aporturilor de caldura prin toate elementele de constructie care delimiteaza camera, in watt-ora. Aceasta valoare reprezinta necesarul de caldura al camerei, sau necesarul termic. Orice modalitate de producere a caldurii in locuinta vom alege, ea ar trebui sa ne ofere, pt. aceasta camera, CEL PUTIN aceasta valoare.Suma acestor valori, pt. toate camerele din intreaga locuinta, ne ofera un MINIM de energie pe care centrala termica, indiferent de care va fi ea, va trebui sa il poata oferi in sezonul rece.Aurel:Aici se afiseaza automat necesarul termic al camerei ( Wh ) raportat la volumul camerei ( mc ).Aurel:Aici se afiseaza automat necesarul termic al camerei ( Wh ) raportat la supra- fata camerei ( mp ).Aurel:In aceasta coloana vom nota lungimea elementului de constructie luat in calcul, in METRI. Adica marimea laturii de pe orizontala, ca sa zic asa, atit la pereti, cit si la ferestre si usi. In cazul podelei, notam oricare dintre laturile ei.In cazul peretilor interiori, acestia se noteaza chiar daca dincolo de ei avem aceeasi temperatura ca si cea interioara camerei pt. care facem calculele, si deci nu are loc schimb termic prin acesti pereti interiori. Pt. calculul AT.Aurel:In aceasta coloana am introdus o serie de elemente de constructie posibile pt. o incapere. Le puteti redenumi, daca doriti. Folositi doar cite aveti nevoie. Primele 3, de pe fiecare parte (perete 1-3-5 si 2-4-6), sint destinate peretilor exteriori (6 in total), iar urmatoarele 4 de pe fiecare parte sint pt. notarea peretilor interiori (8 in total).Atentie: se va nota separat un perete, interior sau exterior ...~~A. ...orice perete, intreg ca atare, cu sau fara ferestre/usi, sau ~~B. ...orice "zona" dintr-un perete, cu sau fara ferestre/usi, DACA indeplineste cel putin una dintre conditiile urmatoare :1. are o structura, respectiv o rezistenta termica, diferita de cea a restului de perete din care face parte, si2. are de partea cealalta a lui o temperatura de calcul diferita de cea a restului de perete din care face parte.Asta este valabil atit in cazul podelei, cit si a tavanului.

Dimensiunea peretilor se calculeaza la interiorul camerei. Se noteaza dimensiunea peretilor CU TOT CU ferestre sau usi, caci programul stie sa scada din suprafata totala a peretelui suprafetele ferestrelor / usilor, pe care le veti introduce tot in coloana din dreapta. Dimensiunile ferestrelor / usilor se masoara din perete in perete.Aurel:Aici vom introduce, in cazul peretilor, ferestrelor si usilor, INALTIMEA lor (h), adica dimensiunea lor pe verticala, tot in METRI.In cazul podelei si tavanului, orice latura a lor sau a unei "zone" din ele (evident, nu pe cea notata alaturi in stinga!).Aurel:Pt. podea si tavan, aici introdu- cem cealalta latura (l) a lor.Daca podeaua sau tavanul au o forma neregulata, compusa din mai multe poligoane sau zone, le puteti nota pe fiecare in parte, iar programul va sti sa le insumeze suprafetele.De asemenea, la fel ca in cazul peretilor, daca anumite zone ale podelei au structuri diferite, SAU sub ele se afla altceva, cu alte temperaturi, decit ceea ce se afla sub restul podelei, atunci va trebui sa le notam separat dimensiunile acestor zone. Sper ca 5 rinduri ajung ...Aurel:Valoarea introdusa aici, pt. inaltimea peretelui, se va copia automat la toti ceilalti pereti, atit exteriori cit si interiori. Asta pt. economie la scris, in cazurile majoritare in care toti peretii unei camere au aceeasi inaltime. Daca in cazul dvs. nu este asa, se poate modifica separat si independent inaltimea fiecarui perete notat in parte.Aurel:In aceasta coloana se vor afisa automat suprafetele elementelor de constructie notate in stinga. In prima celula, se va afisa suprafata toatala, cu tot cu geamuri si/sau usi, a peretelui, iar in celelalte celule suprafetele ferestrelor si / sau usilor notate. Deci, pur si simplu, coloana C inmultit cu coloana D.La fel in cazul podelei si tavanului.Aurel:Aici, in prima celula, in dreptul fiecarui perete, se va afisa automat suprafata de calcul pt. peretele respectiv, adica suprafata zidariei. Adica diferenta dintre suprafata totala a peretelui, cu tot cu ferestre/usi, si suprafata acestor ferestre si/sau usi de pe acel perete.In cazul podelei si tavanului, reprezinta suma suprafatelor tuturor zonelor notate.Aurel:Aici, in dreptul ferestrelor/usilor, se afiseaza automat valoarea totala aproximativa (!!!) a lungimii rosturilor ferestrelor / usilor, pt. cazul in care va este lene sa vi-o calculati exact si sa o scrieti dvs. in celulele respective.Lungimea rosturilor unei ferestre / usi reprezinta suma lungimii laturilor elementelor mobile, care se deschid, luate o singura data.Aceasta valoare este necesara pt. calculul Qi2= caldura necesara incalzirii, de la temp. de afara la cea interioara, a aerului infiltrat prin neetanseitatile usilor si ferestrelor, si a aerului patruns la deschiderea acestora, tinind cont de viteza conventionala a vintului.Aurel:Rc = R' = rezistenta termica corectata = rezistenta termica teoretica ( conform specificatiilor tehnice ale materialelor componente ) a elementului de constructie INMULTITA cu un coeficient de corectie, de obicei subunitar (