    responds to changes in these conditions. Thecurves can then be programmed into yourperformance monitoring system, and used todetermine the corrected performance of your

    unit: the current operating data for your gasturbine (and/or plant) corrected to referenceambient conditions.

    You can then compare your corrected per-formance values (normally output andheat rate) to your design (or baseline) val-ues, and you can also trend them to see howthe unit is degrading over time.

    Because corrected performance values nolonger include the expected changes in per-formance due to ambient conditions, anyvariances observed are due to other

    (potentially controllable) influences. Some ofthe differences could be normal wear & tear(degradation), but changes could also meansomething significant has occurred in the op-eration - either software/controls or hard-ware.

    When trends show large step changes in cor-rected performance, an investigation shouldbe initiated ASAP to determine the cause ofthe change. Step changes in corrected per-formance normally indicate somethingneeds attention whether thats just an in-strument failure, a plug in a fuel filter, or for-eign object damage (FOD) needs to be deter-mined.

    The cause of the change needs to be identi-fied to verify that continuing to run in thecurrent state will not cause additional damage.

    By monitoring your corrected perform-ance, you are on your way to finding theclues to a more reliable and more efficientplant.

    Previous newsletters have dealt with planning andmaintaining your performance monitoring system,but one thing which has not yet been discussed indetail is Corrected Performance.

    Once you have your raw data selected, your sen-sors all calibrated and the data being read, ana-lyzed and archived without a hitch, youre ready tolook at trends. But, the first thing you may notice,is that trends for maximum capacity and heatrate will vary depending on the current ambi-ent conditions (especially for gas turbine basedplants).

    Operators are quick to identify the deficiencies oftheir plants noting that on hot days, the gas tur-bine is output limited. But is this MW limit due tothe ambient conditions alone, or is there some-

    thing else going on? The only way to know, is tohave a baseline set of expectations for the unit asambient conditions change. These expectationsare most often presented to the user as a set ofperformance correction curves, such as the fol-lowing:

    Gas turbine output and heat rate vary with thedensity of the air entering the compressor or,more directly, with compressor inlet temperature,humidity and pressure. The OEM normally pro-vides performance curves for how the gas turbine

    Products & Services

    Analysis Tools

    Excel Workbooks,

    Macros andAdd-Ins:

    Corrected Performance Compressor Efficiency

    Steam & Water Flow

    Moist Air Properties

    Training Seminars

    Compressor Efficiency

    Tracking Software

    Performance Monitor-

    ing Program Design,

    Support and Evaluation

    Read & Comment

    at Tinas Blog:

    www.t2e3.com/blog

    Next LM6000 Seminar

    Scheduled for Septem-

    ber 2009 - see details

    on page 2

    Spring is Here

    BY TINA L. TOBUREN P.E.

    EfficiencyExtraEdition

    T2E3 Newsletter

    May 2009

    Monitoring Corrected PerformanceAnnouncements

  • 7/28/2019 T2E3-2009-1

    2/2

    performance due to ambient condi-

    tions and operating constraints.

    These tools can also lead to a

    greater understanding of the long-

    term economic outlook for your

    facility.

    Unlock the potential of your opera-

    tion. Call for more information on

    how we can work together, today!

    Analysis Tools & Software fromcustomized spreadsheets to add-ins

    for Excel or complete compiled pro-

    grams, T2E3 can develop software

    tools and analyses to support all your

    performance monitoring needs, in-

    cluding integrating your existing

    tools with available site data systems,

    to create online systems providing

    data and results in real-time.

    Training both public seminars andcustomized options are available.

    Highly interactive sessions increase

    attendees knowledge and under-

    standing of the thermodynamic cy-

    cles, instrumentation and analyses

    needed to improve equipment per-

    formance and reliability.

    Performance Test Support if yoursite is required to perform annual

    capacity or PPA performance tests,

    having Tina Toburen from T2E3 on

    site to direct the testing can lead to a

    smoother test execution with more

    consistent performance results. Pro-

    fessional reports can also be pro-

    duced to communicate the results to

    all required parties.

    Site Marketing and Dispatch Sup-

    port Do your marketers and/or dis-patchers understand the operation of

    your facility? Do they constantly dis-

    patch the plant at loads which are

    difficult or impossible to maintain?

    T2E3 can help you build tools and

    training programs to help all parties

    understand the expected changes in

    T2E3 Performance Analysis Services for Power PlantsIncluding:

    T2E3 Add-ins for MS ExcelStreamline your analysis spreadsheets by using functions fromthe T2E3 Automation Add-ins. Available functions include ASMEsteam tables, ASHRAE air properties, orifice flow meter calcula-tions and select performance functions, including: compressorefficiency and evaporative cooler effectiveness.

    For a complete function listing, available options or a trial

    version of an add-in contact T2E3 at 425-821-6036

    14260 120th PL NE

    Kirkland, WA 98034

    Phone: 425-821-6036

    Fax: 253-550-6992

    E-mail: [email protected]

    T2E3Tina ToburensEnergy Efficiency Enterprises

    To receive a copy of this newsletter,along with other announcements for

    T2E3 products and services, send anemail to:

    [email protected]

    and mention this newsletter in the subjector body of the message.

    Your email address will be held in strictconfidence and not be shared with anyother parties.

    To view this or other T2E3 newslettersonline, visit:

    http://www.t2e3.com/news.php

    Seminar: LM6000 Performance Characteristics,

    Testing and Long-Term Condition Monitoring

    The next LM6000 Performance Seminar is currently scheduledfor September 2009, to be convenient for attendees to the AeroUsers Group Annual Conference (http://lm6000.users-groups.com/Events/2009/Info/).

    I am currently looking at holding the seminar on either Mon-

    day & Tuesday before the conference (September 7 & 8) orthe Monday & Tuesday after the conference (September 14 &15). If you would like to attend, and have a preference for thedates, please let me know by sending an email [email protected].

    Additional information on the seminar, including an agenda, canbe found on atwww.t2e3.com/LM6000.php.