M295 M295 M295 M295 EEEE 02.4.CF.2
T-RCP Remote Control Pad
Instructions
- 1 -
Contents
Introduction............................................................................................................................................................. 31 General Description........................................................................................................................... 32 Appearance of Remote Control Pad.................................................................................................. 43 Connection of Remote Control Pad and HUB Controller ................................................................... 54 Startup and Shutdown ....................................................................................................................... 65 Screen Configuration......................................................................................................................... 7
(1) Summary................................................................................................................................. 7(2) Layout of OPERATION Screen ............................................................................................... 7(3) Configuration of SETTING MENU Screens ............................................................................. 8(4) Configuration of MAINTENANCE MENU Screens................................................................. 11
I Preparations ................................................................................................................................................... 121 Connecting and Setting Electrical Components............................................................................... 12
(1) Connecting Electrical Components to HUB Controller ........................................................... 12(2) Turning ON the EXTERNAL Switch of Dia-Illumination Lamp Power Supply......................... 13(3) Placing Uniblitz Shutter Controller into N.C. Mode ................................................................ 13
2 Setting Attachment Information ....................................................................................................... 14(1) Objective ............................................................................................................................... 14(2) Condenser Module ................................................................................................................ 15(3) Filter Block ............................................................................................................................ 16(4) Excitation Filter...................................................................................................................... 17(5) Barrier Filter .......................................................................................................................... 18
3 Setting Uniblitz Shutter Controller Connection................................................................................. 194 Setting Shutter Key Function ........................................................................................................... 205 Setting Foot Switch Function ........................................................................................................... 216 Indicating Z-Axis Position ................................................................................................................ 22
II Basic Operation .............................................................................................................................................. 231 Selecting Objective Lens ................................................................................................................. 232 Selecting Filter Block ....................................................................................................................... 243 Selecting Optical Path ..................................................................................................................... 254 Selecting Condenser Module........................................................................................................... 255 Selecting Excitation Filter ................................................................................................................ 266 Selecting Barrier Filter ..................................................................................................................... 267 Inserting/Removing Analyzer........................................................................................................... 278 Opening/Closing Shutter ................................................................................................................. 279 Operating Dia-Illumination Lamp (12V100W lamp only) .................................................................. 27
(1) Turning Remote Control Operation ON/OFF ......................................................................... 27(2) Turning Lamp ON/OFF.......................................................................................................... 28(3) Adjusting Lamp Voltage......................................................................................................... 28
10 Resetting Z-Axis Position to Zero .................................................................................................... 2911 Outputting External Trigger.............................................................................................................. 29
III Additional Functions ....................................................................................................................................... 301 Interlocking Objective and Condenser Module Selection................................................................. 302 Interlock Filter Block and Excitation/Barrier Filters Selection ........................................................... 313 Restricting Rotation of Revolving Nosepiece ................................................................................... 32
(1) Set Rotation Restriction......................................................................................................... 32(2) Cancel Rotation Restriction ................................................................................................... 33
IV Other Operations ............................................................................................................................................ 341 Operating LCD Backlight ................................................................................................................. 34
(1) Turning Backlight ON/OFF .................................................................................................... 34(2) Adjusting Brightness of Backlight .......................................................................................... 34
- 2 -
2 Adjusting LCD Contrast ................................................................................................................... 35V Operation and Indication Functions ................................................................................................................ 36
1 Changing Operation Mode of Fine Focus Knob............................................................................... 362 Setting Indication on Operation Screen ........................................................................................... 373 Setting Buzzer ON/OFF................................................................................................................... 384 Setting Remote Control ON/OFF..................................................................................................... 395 Turning ON/OFF LED with LCD ON/OFF Key ................................................................................. 406 Setting Communications Delimiter of External Device ..................................................................... 417 Registering Data for Optical Members............................................................................................. 42
(1) Objective ............................................................................................................................... 42(2) Condenser Module ................................................................................................................ 44(3) Filter Block ............................................................................................................................ 45(4) Dichroic Mirror ....................................................................................................................... 47(5) Excitation Filter...................................................................................................................... 48(6) Barrier Filter .......................................................................................................................... 49
VI Maintenance Menu ......................................................................................................................................... 501 Indicating Program Version and Checksum..................................................................................... 502 Testing Electrical Component Operations ....................................................................................... 51
(1) All-Test Mode ........................................................................................................................ 51(2) Individual Test Mode ............................................................................................................. 53
3 Testing Hardware of Remote Control Pad ....................................................................................... 54(1) Key Input Test ....................................................................................................................... 54(2) LED ON/OFF Test................................................................................................................. 55(3) LCD Indication Test............................................................................................................... 55
4 Initializing Focus Motion Potentiometer ........................................................................................... 565 Resetting Remote Control Pad Settings to Default Values .............................................................. 576 Resetting HUB Controller Settings to Default Values....................................................................... 587 Reset Control Data to Default Values .............................................................................................. 59
(1) All Components ..................................................................................................................... 59(2) Revolving Nosepiece............................................................................................................. 60(3) Condenser Module ................................................................................................................ 61(4) Optical Path........................................................................................................................... 62(5) Filter Block ............................................................................................................................ 63(6) Excitation Filter...................................................................................................................... 64(7) Barrier Filter .......................................................................................................................... 65(8) Auxiliary Filter........................................................................................................................ 66
VII Troubleshooting .............................................................................................................................................. 671 Remote control pad doesn’t start up. (TITLE screen appears, and the screen freezes.).................. 672 Electrical component doesn’t operate.............................................................................................. 673 Revolving nosepiece doesn’t rotate at a certain position of the fine focus knob............................... 674 Dia-illumination lamp cannot be turned ON or OFF. ........................................................................ 675 Voltage of dia-illumination lamp cannot be adjusted. ....................................................................... 686 Opening/closing status of Uniblitz shutter doesn’t coincide with LED indication. ............................. 687 Objective information is not indicated. ............................................................................................. 688 Condenser module information is not indicated. .............................................................................. 689 Filter block information is not indicated............................................................................................ 6810 Excitation filter information is not indicated. ..................................................................................... 6911 Barrier filter information is not indicated........................................................................................... 6912 Dia-illumination lamp voltage is not indicated. ................................................................................. 6913 Z-axis coordinates are not indicated. ............................................................................................... 6914 Buzzer doesn’t sound when a key is pressed. ................................................................................. 69
Introduction
1 General Description
- 3 -
Introduction
1 General Description
The remote control pad is connected to the HUB controller and used for remote control of the accessory electricalcomponents of the ECLIPSE TE2000 series.
The remote control pad enables control of the electrical components with key operations on the pad. The remotecontrol pad also indicates a variety of information using the LED and displays on the LCD, such as electricalcomponent positions and information on the attached optical members.
Introduction
2 Appearance of Remote Control Pad
- 4 -
2 Appearance of Remote Control Pad
1
2
34
56
7
8 9
1011
12
1314
15
16
17
18
No. Parts Function whenOPERATION screen is indicated
Functions when settingmenu/maintenance menu is indicated
1 Liquid crystal display (LCD)
OPERATION screen: Indicateselectrical component positions andinformation on the attached opticalmembers
Setting menu: Allows setting ofvarious functions/parameters of theelectrical components.
2 OBJECTIVE key Selects an objective lens
3 SHUTTER A key Opens/closes the shutter allocated toShutter A key
4 SHUTTER B key Opens/closes the shutter allocated toShutter B key
5 EXCITER key Selects an excitation filter6 BARRIER key Selects a barrier filter
Enters alphanumeric characters.
7 EPI-FILTER key Selects a filter block8 Z-AXI. RESET key Resets the z-axis position to zero9 CAMERA EXP. key Outputs an external trigger
10 LCD MODE key Changes to another screen Changes to another screen.11 LCD ON/OFF key Turns ON/OFF the LCD backlight
12 LCD Bright/Dark key Adjusts the brightness of the LCDbacklight
13 DIA LAMP REMOTE key Turns ON/OFF the remote controloperation of the dia-illumination lamp
14 DIA LAMP ON/OFF key Turns ON/OFF the dia-illuminationlamp
15 DIA LAMP ADJ. key Adjusts the voltage of the dia-illumination lamp PREV/NEXT keys (Change selection.)
16 CONDENSER key Selects a condenser module BS key (Deletes entered letters), CLRkey (All clear)
17 ANALYZER IN/OUT key Inserts/removes the analyzer
18 LIGHT PATH key Selects an optical pathCursor key (Selects an item.)Return key (Confirms selection.)
Introduction
3 Connection of Remote Control Pad and HUB Controller
- 5 -
3 Connection of Remote Control Pad and HUB Controller
Connect the HUB connection cable fixed to the remote control pad to REMOTE connector of the HUB controller asshown below.
Hub connection cable
[Rear panel of remote control pad]
REMOTE connector
[Connector panel of HUB controller]
Introduction
4 Startup and Shutdown
- 6 -
4 Startup and Shutdown
1 Startup1) Turn ON power for the dia-illumination lamp. When
using Uniblitz shutter, also turn ON power for theUniblitz shutter controller.
2) Turn ON the power to the HUB controller.
3) Power is supplied to the remote control pad from theHUB controller.
AC
[Side panel of HUB controller]
The TITLE screen appears on the LCD of the remote control pad and changes to the OPERATION screen in 2 or 3seconds.
T-RCP REMOTE CONTROL PAD
V1.00
[TITLE screen] [OPERATION screen]
Note:When you use the remote control pad for the first time, all the optical members, such as the objectives, willbe set by default to “Not attached” and the Operation screen will appear as shown below.
“---------” indicates that the opticalmember is “not attached.”
If an electric component is not connected to the HUB controller, the indication of the component will be blank.If the electrical component is not connected to the HUB controller correctly, the HUB controller cannot detectthe component and the indication of the component will also be blank.If no electrical component is connected to the HUB controller, the screen will appear as shown below.
2 Shutdown1) Turn OFF the power to the HUB controller.
2) Turn OFF power for the dia-illumination lamp and theUniblitz shutter controller.
Power switch
Connect the specified AC adapter
Introduction
5 Screen Configuration
- 7 -
5 Screen Configuration
(1) Summary
Power ON
MODE key
MODE key
Is MODE keypressed?
MODE keyNo
Yes
T-RCP REMOTE CONTROL PAD
V1.00
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
Note:If power is turned ON while the MODE key is held down, the MAINTENANCE MENU screen will appear.
(2) Layout of OPERATION Screen
Objective lensinformation
P. 14
Condenser moduleinformationP. 15
Excitation filterinformationP. 17
Barrier filterinformationP. 18
Filter block informationP. 16
Z-axis positionP. 21
Dia-Illuminationlamp voltage
P. 28
Note:If the electric components are not connected to the HUB controller, information for the unconnectedcomponents will not appear.
Introduction
5 Screen Configuration
- 8 -
(3) Configuration of SETTING MENU Screens
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
OBJECTIVESeries Mag.
1[P Fluor ][DL 4x ]
2[P Fluor ][DL 10x ]
3[P Fluor ][ELWD DM 20x ]
4[P Fluor ][ELWD DM 40x ]
5[P Fluor ][ELWD DLL 60x ]
6[P Fluor ][DLL 100x ]
Edit Type N.A. W.D. Dry 0.13 17.10
CONDENSERName
1[BF ]
2[PhL ]
3[Ph1 ]
4[Ph2 ]
5[Ph3 ]
Edit
FILTERName
1[UV-1A ] EX : EX365/10
2[V-1A ] DM : DM400
3[BV-1A ] BA : BA400
4[B-1A ]
5[G-1A ]
6[DIA ]
Edit
EXCITER
Name1[EX465-495 ]5[――――――――――]
2[EX460-500 ]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
BARRIER
Name1[BA515-555 ]5[――――――――――]
2[BA510 ]6[――――――――――]
3[BA510-560 ]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
COMBINATION(OBJ.>CONDENSER)
Objective Condenser1.P Fluor DL 4x [2]:PhL
2.P Fluor DL 10x [3]:Ph1
3.P Fluor ELWD DM 20x [3]:Ph1
4.P Fluor ELWD DM 40x [4]:Ph2
5.P Fluor ELWD DLL 60x [4]:Ph2
6.P Fluor DLL 100x[5]:Ph3
COMBINATION(FILTER>EX/BA)
Filter EX BA1.UV-1A [-]:―――――――[-]:―――――――
2.V-1A [-]:―――――――[-]:―――――――
3.BV-1A [-]:―――――――[-]:―――――――
4.B-1A [1]:465-495[1]:515-555
5.G-1A [-]:―――――――[-]:―――――――
6.DIA [8]:DIA [8]:DIA
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
*1
*3
*4
*5
*6
*2
MODE key
[ ] key
Introduction
5 Screen Configuration
- 9 -
OBJECTIVESeries Mag.
1[P Fluor ][DL 4x ]
2[P Fluor ][DL 10x ]
3[P Fluor ][ELWD DM 20x ]
4[P Fluor ][ELWD DM 40x ]
5[P Fluor ][ELWD DLL 60x ]
6[P Fluor ][DLL 100x ]
Edit Type N.A. W.D. Dry 0.13 17.10
CONDENSERName
1[BF ]
2[PhL ]
3[Ph1 ]
4[Ph2 ]
5[Ph3 ]
Edit
FILTERName
1[UV-1A ] EX : EX365/10
2[V-1A ] DM : DM400
3[BV-1A ] BA : BA400
4[B-1A ]
5[G-1A ]
6[DIA ]
Edit
EXCITER
Name1[EX465-495 ]5[――――――――――]
2[EX460-500 ]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
BARRIER
Name1[BA515-555 ]5[――――――――――]
2[BA510 ]6[――――――――――]
3[BA510-560 ]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[――――――――――]
Mag. :[0 ]x
N.A. :[0 ]
W.D. :[0 ]
Type :[――――――――――]
EDIT CONDENSER DATA
Location:[Other1]
Name :[ ]
EDIT FILTER DATA
Location:[Other1]
Name :[ ]
EX :[――――――――――]Edit
DM :[――――――――――]Edit
BA :[――――――――――]Edit
EDIT DM DATA
Location:[Other1]
Name :[ ]
EDIT EX DATA
Location:[Other1]
Name :[ ]
EDIT BA DATA
Location:[Other1]
Name :[ ]
EDIT BA DATA
Location:[Other1]
Name :[ ]
EDIT EX DATA
Location:[Other1]
Name :[ ]
*1
*2
*3
*4
*5
Introduction
5 Screen Configuration
- 10 -
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
ROTATION STOPPER
Current setting:OFF
ON OFF
FINE FOCUS KNOB
[100]μm/rot.
OTHER UNIT
UNIBlitze Shutter :[OFF]
REMOTE CONTROL PAD
DisplayObjective :[ON ]Condenser :[ON ]Filter :[ON ]Exciter :[ON ]Barrier :[ON ]
DIA Lamp :[ON ]Z-Position :[OFF]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
SHUTTER KEY
Shutter A Shutter B[ ][ ]
FOOT SWITCH
Unused
Revolving nosepiece
Condenser cassette
Filter block
Exciter filter
Barrier filter
AUX filter
COMMUNICATION DELIMITERFOR EXTERNAL UNIT
CR LF
MODE key
*6
[ ] key
Introduction
5 Screen Configuration
- 11 -
(4) Configuration of MAINTENANCE MENU Screens
PAD DATA
Initialize PAD data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes
and press ENTER to start.
HUB DATA
Initialize HUB data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start.
TEST1 1/5→ ALL TEST
OBJECTIVE 1 [ ] 2 [ ] 3 [ ] 4 [ ] 5 [ ] 6 [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select item and press enter to start.
VERSION
T-RCP REMOTE CONTROL PADV1.00 Sum=1234
T-HUBC HUB CONTROLLERMAIN-cpu: V1.00 Sum=5678SUB-cpu : V1.00 Sum=ABCD
CONTROL DATA
Initialize all control data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX filter
Control Data
Initialize Control data for AUX filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start.
・・・・・・
[ ] key
MODE key
I Preparations
1 Connecting and Setting Electrical Components
- 12 -
IPreparations
1 Connecting and Setting Electrical Components
(1) Connecting Electrical Components to HUB Controller
Make sure that the power switches for the microscope and the HUB controller are OFF.
Connect the electrical components to be used to the HUB controller.
Revolving nosepiece(Motorized nosepiece)
Analyzer(Motorized analyzer)
Excitation filter changeover(Ex filter wheel)
Episcopic illuminationshutter(Motorized Epi-fl attachment)
Barrier filter changeover(BA filter wheel)
Filter block changeover(Motorized cassetteholder)
Condenser modulechangeover (Motorizedcondenser turret)
Reserve connector(not used)
PCExternal device(XY stage, etc.)
Uniblitz shuttercontroller
Remote control pad
Dia-Illumination lamp power supply(TS2-PS100W power supply)* TE-PS30 and TE-PSE30 powersupplies cannot be connected.
Foot switch, etc.
[Connector panel of HUB controller]
I Preparations
1 Connecting and Setting Electrical Components
- 13 -
I
(2) Turning ON the EXTERNAL Switch of Dia-Illumination Lamp Power Supply
EXTERNAL switch
[Rear panel of dia-illumination lamp power supply]
Note:When the EXTERNAL switch is OFF, you cannot operate the dia-illumination lamp on the remote control pad.
A 30-W power supply cannot be connected to the HUB controller.
(3) Placing Uniblitz Shutter Controller into N.C. Mode
Be sure to set the controller to the N.C. mode when using the Uniblitz shutter.
Turn the switch of the channel used to N.C.
UNIBLITZ
[Front panel of Uniblitz shutter controller]
Note:N.C. stands for Normal Close.
If the Uniblitz shutter controller is set to the N.C. mode, when power is turned on, the controller starts up with theshutter closed.
I Preparations
2 Setting Attachment Information
- 14 -
2 Setting Attachment Information
Start up the remote control pad and set the optical members attached to the electrical components in use.
The LCD indicates information for the set optical members.
(1) Objective
Set the information on objectives attached to the revolving nosepiece (motorized nosepiece).
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Objective” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Series” for the objective using the PREV or NEXTkey.
Note:The numbers at the left of the screen represent theaddresses of the revolving nosepiece.
OBJECTIVESeries Mag.
1[P Fluor ][―――――――――――――――――]
2[――――――――――][―――――――――――――――――]
3[――――――――――][―――――――――――――――――]
4[――――――――――][―――――――――――――――――]
5[――――――――――][―――――――――――――――――]
6[――――――――――][―――――――――――――――――]
Edit Type N.A. W.D. Dry 0.13 17.10
3 Move the cursor using the key or the key.
Select “Mag.” for the objective using the PREV or NEXTkey.
OBJECTIVESeries Mag.
1[P Fluor ][DL 4x ]
2[――――――――――][―――――――――――――――――]
3[――――――――――][―――――――――――――――――]
4[――――――――――][―――――――――――――――――]
5[――――――――――][―――――――――――――――――]
6[――――――――――][―――――――――――――――――]
Edit Type N.A. W.D. Dry 0.13 17.10
4 Move to the next address of the revolving nosepiece usingthe key or the key. Repeat steps 2 and 3 above.
OBJECTIVESeries Mag.
1[P Fluor ][DL 4x ]
2[――――――――――][―――――――――――――――――]
3[――――――――――][―――――――――――――――――]
4[――――――――――][―――――――――――――――――]
5[――――――――――][―――――――――――――――――]
6[――――――――――][―――――――――――――――――]
Edit Type N.A. W.D. ―――――――――― ――――― ―――――
5 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:If the revolving nosepiece is not connected, you cannot set the information on objectives.
“---------” indicates that no objective is attached or registered at the address.
If an attached objective is not listed among the presets, register it to the list of optional objectives.
For details, see V-7 (2) Objective in section V-7 (Registering Data for Optical Members).
I Preparations
2 Setting Attachment Information
- 15 -
I
(2) Condenser Module
Set the information on condenser modules attached to the condenser module changeover (motorized condenserturret).
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Condenser” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Name” for the condenser module using the PREVor NEXT key.
If the condenser module is marked “A,” select “BF.”Note:
The numbers at the left of the screen represent theaddresses of the condenser module changeover.
CONDENSERName
1[BF ]
2[――――――――――]
3[――――――――――]
4[――――――――――]
5[――――――――――]
Edit
3 Move to the next address of the condenser modulechangeover using the key or the key. Repeat step 2above.
CONDENSERName
1[BF ]
2[――――――――――]
3[――――――――――]
4[――――――――――]
5[――――――――――]
Edit
4 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:If the condenser module changeover is not connected, you cannot set the information on condenser modules.
“---------” indicates that no condenser module is attached or registered at the address.
If an attached condenser module is not listed in the presets, register it to the list of optional condenser modules.
For details, see V-7 (2) Condenser Module in section V-7 (Registering Data for Optical Members).
I Preparations
2 Setting Attachment Information
- 16 -
(3) Filter Block
Set the information on filter blocks attached to the filter block changeover (motorized cassette holder).
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Filter” using the key or the key and then pressthe [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Name” for the filter block using the PREV or NEXTkey.
Note:The numbers at the left of the screen represent theaddresses of the filter block changeover.
FILTERName
1[UV-1A ] EX : EX365/10
2[――――――――――] DM : DM400
3[――――――――――] BA : BA400
4[――――――――――]
5[――――――――――]
6[――――――――――]
Edit
3 Move to the next address of the filter block changeoverusing the key or the key. Repeat step 2 above.
FILTERName
1[UV-1A ] EX : ――――――――――
2[――――――――――] DM : ――――――――――
3[――――――――――] BA : ――――――――――
4[――――――――――]
5[――――――――――]
6[――――――――――]
Edit
4 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:If the filter block changeover is not connected, you cannot set the information on filter blocks.
“---------” indicates that no filter block is attached or registered at the address.
If a filter block attached is not in the presets, register it to the list of optional filter blocks. For details, see V-7 (3)Filter Block in section V-7 (Registering Data for Optical Members).
I Preparations
2 Setting Attachment Information
- 17 -
I
(4) Excitation Filter
Set the information on excitation filters attached to the excitation filter changeover (EX filter wheel).
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Exciter” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Name” for the excitation filter using the PREV orNEXT key.
Note:The numbers at the left of the screen represent theaddresses of the excitation filter changeover.
EXCITER
Name1[EX465-495 ]5[――――――――――]
2[――――――――――]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[――――――――――]
Edit
3 Move to the next address of the excitation filter changeoverusing the key or the key. Repeat step 2 above.
EXCITER
Name1[EX465-495 ]5[――――――――――]
2[――――――――――]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[――――――――――]
Edit
4 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:If the excitation filter changeover is not connected, you cannot set the information on excitation filters.
“---------” indicates that no excitation filter is attached or registered at the address.
If an attached excitation filter is not listed in the presets, register it to the list of optional excitation filters. For details,see V-7 (5) Excitation Filter in section V-7 (Registering Data for Optical Members).
If any of the openings in the changeover is empty (i.e., in the DIA position) when switching from one excitation filterto another, a bright light may enter the observation side, depending on the layout of the optical members,temporarily affecting your vision. To prevent this, we recommend that you attach excitation filters to thechangeover, as shown below.
Sample layout of excitation filters
12
3
45
6
7
8
Set Address 8 to DIA (empty). Attach excitation filters from Address 1 forward,leaving no empty openings in-between.
Put a light shielding plate on the openingswith no filter attached.
Excitation filter changeover(EX filter wheel)
[Excitation filter attaching side]
I Preparations
2 Setting Attachment Information
- 18 -
(5) Barrier Filter
Set the information on barrier filters attached to the barrier filter changeover (BA filter wheel).
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Barrier” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Name” for the barrier filter using the PREV or NEXTkey.
Note:The numbers at the left of the screen represent theaddresses of the barrier filter changeover.
BARRIER
Name1[BA515-555 ]5[――――――――――]
2[――――――――――]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[――――――――――]
Edit
3 Move to the next address of the barrier filter changeoverusing the key or the key. Repeat step 2 above.
BARRIER
Name1[BA515-555 ]5[――――――――――]
2[――――――――――]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[――――――――――]
Edit
4 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:If the barrier filter changeover is not connected, you cannot set the information on barrier filters.
“---------” indicates that no barrier filter is attached or registered at the address.
If a barrier filter attached is not in the presets, register it to the list of optional barrier filters. For details, see V-7 (6)Barrier Filter in section V-7 (Registering Data for Optical Members).
I Preparations
3 Setting Uniblitz Shutter Controller Connection
- 19 -
I
3 Setting Uniblitz Shutter Controller Connection
The HUB controller doesn’t automatically detect the Uniblitz shutter controller, unlike other electrical components.Be sure to set the connection of the Uniblitz shutter controller when using the Uniblitz shutter.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and then pressthe [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Other Unit” using the key or the key and thenpress the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Select “ON” using the PREV or NEXT key. OTHER UNIT
UNIBlitze Shutter :[ON ]
4 Press the MODE key to end the setting and to return to theOPERATION screen.
I Preparations
4 Setting Shutter Key Function
- 20 -
4 Setting Shutter Key Function
Allocate the shutters to the Shutter A and Shutter B keys.
1 Press the MODE key, and the SETTING MENU screen willappear on
Select “More” using the key or the key and then pressthe [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Shutter Key” using the key or the key andthen press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Select a shutter to be operated by the SHUTTER A keyusing the PREV or NEXT key.
SHUTTER KEY
Shutter A Shutter B[Epi shutter] [OFF ]
4 Move the cursor using the key or the key.
Select a shutter to be operated by the SHUTTER B keyusing the PREV or NEXT key.
SHUTTER KEY
Shutter A Shutter B[Epi shutter] [UNI CH.#1 ]
5 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:If the Nikon motorized Epi-Fl attachment is not connected and the Uniblitz shutter controller connection is set to“OFF,” you cannot set the shutter key function.For details on the Uniblitz shutter controller connection setting, see section I-3 (Setting Uniblitz Shutter ControllerConnection).
You can’t allocate the same shutter to both the Shutter A and the Shutter B keys.
I Preparations
5 Setting Foot Switch Function
- 21 -
I
5 Setting Foot Switch Function
Allocate an electrical component to the foot switch.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and then pressthe [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Foot Switch” using the key or the key andthen press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Move the cursor using the key or the key and selectan electrical component.
FOOT SWITCH
Unused
Revolving nosepiece
Condenser cassette
Filter block
Exciter filter
Barrier filter
AUX filter
4 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:If a component is not connected, you cannot select the component.
If the selected electrical component is disconnected while the OPERATION screen is displayed on the LCD, thecomponent is automatically set to “Unused.”
I Preparations
6 Indicating Z-Axis Position
- 22 -
6 Indicating Z-Axis Position
Indication of the z-axis position is set to “OFF” by default.
To indicate the z-axis position, edit the setting using the following procedure. (If TE2000-U or TE2000-S is used,the Z-Axis Position cannot be indicated.)
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and then pressthe [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Remote Control Pad” using the key or the keyand then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Select “Z-Position” using the key or the key andselect “ON” using the PREV or NEXT key.
REMOTE CONTROL PAD
DisplayObjective :[ON ]Condenser :[ON ]Filter :[ON ]Exciter :[ON ]Barrier :[ON ]
DIA Lamp :[ON ]Z-Position :[ON ]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
4 Press the MODE key to end the setting and to return to theOPERATION screen.
II Basic Operation
1 Selecting Objective
- 23 -
II
IIBasic Operation
1 Selecting Objective
Press the OBJECTIVE key to select an objective.
Each OBJECTIVE key corresponds to one of theobjectives; you can select an objective by simply pressingthe key corresponding to the objective.
(3)
Screen indication:
(1) The series name of the objective in the optical path isindicated.
(2) The magnification of the objective in the optical pathis highlighted.
LED INDICATION:
(3) The LED of the OBJECTIVE key corresponding tothe objective in the optical path is lit green.
(2) (1)
Note:If the revolving nosepiece is not connected, the objective information will not be indicated on the LCD and the LED ofOBJECTIVE key will not light up.
II Basic Operation
2 Selecting Filter Block
- 24 -
2 Selecting Filter Block
Press the FILTER key to select a filter block.
Each FILTER key corresponds to one of the filter blocks;you can select a filter block by simply pressing the keycorresponding to the block.
(4)
Screen indication:
(1) The name of the filter block in the optical path isindicated.
(2) The excitation method of the filter block is indicated.If the filter block is in the optical path, the excitationmethod is highlighted.
If no filter block is attached, “---------“ is indicated. Ifa registered filter block is attached, “O” (= Other) isindicated.
(3) The wavelengths of the excitation filter, dichroicmirror, and barrier filter, which make up the filterblock, are indicated.
LED INDICATION:
(4) The LED of the FILTER key corresponding to thefilter block in the optical path is lit green.
(1)(2) (3)
Note:If the filter block changeover is not connected, the filter block information will not be indicated on the LCD and theLED of FILTER key will not light up.
II Basic Operation
3 Selecting Optical Path
- 25 -
II
3 Selecting Optical Path
Press the LIGHT PATH key to select an optical path.
Each LIGHT PATH key corresponds to one of the opticalpaths; you can select an optical path by simply pressingthe key corresponding to the path.
LED INDICATION:
(1) The LED of the LIGHT PATH key corresponding tothe currently selected optical path is lit green.
(1)
Note:If TE2000-U or TE2000-S is used, you cannot use the LIGHT PATH keys to select an optical path. Use optical pathswitchover dial on the microscope instead.
4 Selecting Condenser Module
Press the CONDENSER key to turn the condenser modulechangeover clockwise or counterclockwise to select acondenser module.
Screen indication:
(1) The currently selected address in the condensermodule changeover is indicated.
(2) The name of the condenser module in the opticalpath is indicated.
(1) (2)
Note:If the condenser module changeover is not connected, the condenser module information will not be indicated onthe LCD.
II Basic Operation
5 Selecting Excitation Filter
- 26 -
5 Selecting Excitation Filter
Press the EXCITER key to turn the excitation filterchangeover clockwise or counterclockwise to select anexcitation filter.
Screen indication:
(1) The currently selected address in the excitation filterchangeover is indicated.
(2) The wavelength of the excitation filter in the opticalpath is indicated. (1) (2)
Note:If the excitation filter changeover is not connected, the excitation filter information will not be indicated on the LCD.
If any of the openings in the changeover is empty (i.e., in the DIA position) when switching over one excitation filterto another, a bright light may enter the observation side, depending on the layout of the optical members. The lightmay temporarily impair your vision or the object may be unnecessarily exposed to light.
To prevent this, we recommend that you close the episcopic illumination shutter when switching over excitationfilters.
6 Selecting Barrier Filter
Press the BARRIER key to turn the barrier filterchangeover clockwise or counterclockwise to select abarrier filter.
Screen indication:
(1) The currently selected address in the barrier filterchangeover is indicated.
(2) The wavelength of the barrier filter in the optical pathis indicated.
(1) (2)
Note:If the barrier filter changeover is not connected, the barrier filter information will not be indicated on the LCD.
II Basic Operation
7 Inserting/Removing Analyzer
- 27 -
II
7 Inserting/Removing Analyzer
Press the ANALYZER IN/OUT key to insert and removethe analyzer.
LED INDICATION:
IN OUTGreen Orange
Note:If the analyzer is not connected, the LED will not light up.
8 Opening/Closing Shutter
Press the SHUTTER A key to open and close the shutterallocated to SHUTTER A.
Press the SHUTTER B key to open and close the shutterallocated to SHUTTER B.
LED INDICATION:
OPEN CLOSEGreen Orange
Note:If the allocation for the SHUTTER A key and the SHUTTER B key is set to “OFF,” the LED will not light up.
For details on shutter allocation, see section I-4 (Setting Shutter Key Function).
9 Operating Dia-Illumination Lamp (12V100W lamp only)
(1) Turning Remote Control Operation ON/OFF
Remote control operation refers to operating the dia-illumination lamp of the microscope from the remote controlpad.
Press the DIA LAMP REMOTE key to turn remote controloperation ON or OFF.
LED INDICATION:
Operation ON Operation OFFGreen Orange
Note:When EXTERNAL switch of the dia-illumination lamp power supply is OFF, you cannot operate the lamp on theremote control pad nor turn the remote control operation ON or OFF. The LED will not light up.
II Basic Operation
9 Operating Dia-Illumination Lamp (12V100W lamp only)
- 28 -
(2) Turning Lamp ON/OFF
You can turn the lamp ON or OFF as long as the LED ofthe REMOTE key is green.
Press the DIA LAMP ON/OFF key to turn the lamp ON orOFF.
LED INDICATION:
Lamp ON Lamp OFFGreen Orange
Note:When the LED of the DIA LAMP REMOTE key is orange or is unlit, the LED of the DIA LAMP ON/OFF key will notlight up.
(3) Adjusting Lamp Voltage
You can adjust the lamp voltage as long as the LED of theREMOTE key is green.
Press the DIA LAMP ADJ. key to adjust the lamp voltage.
Screen indication:
(1) The lamp voltage is indicated with a resolution of0.5 v.
For example, if the voltage is 9 v or more and below9.5 v, it will be indicated as 9 v.
Indication examples:
0 v
Below 3 v
3 vbelow 3.5 v
12 v or more
(1)
Note:When the LED of the DIA LAMP REMOTE key is orange or is unlit, the lamp voltage will not be indicated.
Adjusting the lamp voltage will also alter the color cast of the light. When color fidelity is important - for example,when taking a color photo, - use an ND filter to adjust brightness.
II Basic Operation
10 Resetting Z-Axis Position to Zero
- 29 -
II
10 Resetting Z-Axis Position to Zero
The current z-axis position can be indicated as 0.00 µm.
Press the Z-AXI. RESET key to set the indication of the z-axis position to zero.
Screen indication:
(1) The z-axis position is indicated.
(1)
Note:When the indication of the z-axis position is OFF, you cannot reset the indication to zero.
If TE2000-U or TE2000-S is used, the Z-axis position cannot be indicated.
11 Outputting External Trigger
You can click the shutter of the 35-mm camera connectedto the HUB controller.
Press the CAMERA EXP. key to output an external trigger.
Note:For information about connection to a camera, refer to 22, “Connection to the EXP Connector,” in “VI. Assembly” inthe “Motorized Units for ECLIPSE TE2000-E/TE2000-U/TE2000-S”manual.
III Additional Functions
1 Interlocking Objective and Condenser Module Selection
- 30 -
IIIAdditional Functions
1 Interlocking Objective and Condenser Module Selection
If combinations of objectives and condenser modules are set, then when an objective is selected, the condensermodule corresponding to the objective is automatically selected.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Combination (OBJ>Condenser)” using the keyor the key and then press the [ ] key .
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select the address in the condenser module changeover tointerlock with Address 1 of the revolving nosepiece usingthe PREV or NEXT key.
COMBINATION(OBJ.>CONDENSER)
Objective Condenser1.P Fluor DL 4x [2]:PhL
2.P Fluor DL 10x [-]:―――――
3.P Fluor ELWD DM 20x [-]:―――――
4.P Fluor ELWD DM 40x [-]:―――――
5.P Fluor ELWD DLL 60x [-]:―――――
6.P Fluor DLL 100x[-]:―――――
3 Move to the next address of the revolving nosepiece usingthe key or the key and repeat step 2 above.
COMBINATION(OBJ.>CONDENSER)
Objective Condenser1.P Fluor DL 4x [2]:PhL
2.P Fluor DL 10x [-]:―――――
3.P Fluor ELWD DM 20x [-]:―――――
4.P Fluor ELWD DM 40x [-]:―――――
5.P Fluor ELWD DLL 60x [-]:―――――
6.P Fluor DLL 100x[-]:―――――
4 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:“-” indicates that the address is not interlocked.
Unless both the revolving nosepiece and the condenser module changeover are connected, you cannot set thecombinations.
III Additional Functions
2 Interlock Filter Block and Excitation/Barrier Filters Selection
- 31 -
III
2 Interlock Filter Block and Excitation/Barrier Filters Selection
If combinations of filter block and excitation/barrier filters are set, then when a filter block is selected, theexcitation/barrier filters corresponding to the block are automatically selected.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Combination (FILTER>EX/BA)” using the key orthe key and then press the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select the address in the excitation filter changeover tointerlock with Address 1 of the filter block changeover usingthe PREV or NEXT key.
COMBINATION(FILTER>EX/BA)
Filter EX BA1.UV-1A [8]:DIA [-]:―――――――
2.V-1A [-]:―――――――[-]:―――――――
3.BV-1A [-]:―――――――[-]:―――――――
4.B-1A [-]:―――――――[-]:―――――――
5.G-1A [-]:―――――――[-]:―――――――
6.DIA [-]:―――――――[-]:―――――――
3 Move the cursor using the key or the key.
Select the address in the barrier filter changeover tointerlock with Address 1 of the filter block changeover usingthe PREV or NEXT key.
COMBINATION(FILTER>EX/BA)
Filter EX BA1.UV-1A [8]:DIA [-]:―――――――
2.V-1A [-]:―――――――[-]:―――――――
3.BV-1A [-]:―――――――[-]:―――――――
4.B-1A [-]:―――――――[-]:―――――――
5.G-1A [-]:―――――――[-]:―――――――
6.DIA [-]:―――――――[-]:―――――――
4 Move to the next address of the filter block changeoverusing the key or the key and repeat steps 2 and 3above.
COMBINATION(FILTER>EX/BA)
Filter EX BA1.UV-1A [8]:DIA [8]:DIA
2.V-1A [-]:―――――――[-]:―――――――
3.BV-1A [-]:―――――――[-]:―――――――
4.B-1A [-]:―――――――[-]:―――――――
5.G-1A [-]:―――――――[-]:―――――――
6.DIA [-]:―――――――[-]:―――――――
5 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:“-” indicates that the address is not interlocked.
Unless the filter block changeover is connected and either the excitation filter changeover and barrier filterchangeover is connected (or both are connected), you cannot set the combinations.
III Additional Functions
3 Restricting Rotation of Revolving Nosepiece
- 32 -
3 Restricting Rotation of Revolving Nosepiece
You can restrict the rotation of the revolving nosepiece with the OBJECTIVE key, so that the revolving nosepiecewill not turn from the set z-axis position and upward. The upper limit setting is effective for all the addresses of therevolving nosepiece.
(1) Set Rotation Restriction
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Rotation Stopper” using the key or the keyand then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Move the z-axis position to the position to restrict therevolving nosepiece rotation (the position at which youwant the revolving nosepiece to stop turning).
4 Move the cursor to “ON” using the key or the key andthen press the [ ] key.
ROTATION STOPPER
Current setting:OFF
ON OFF
5 A confirmation message appears.
Press the [ ] key.
To cancel, move the cursor to “NO” using the key or the key and then press the [ ] key.
ROTATION STOPPER
Current setting:ON
ON OFF
Rotation stopper ON ?
Yes No
6 When the setting is accepted, the “Complete!” messageappears and remains displayed for about one second.
ROTATION STOPPER
Current setting:ON
ON OFF
Complete!
7 Press the MODE key to end the setting and to return to theOPERATION screen.
III Additional Functions
3 Restricting Rotation of Revolving Nosepiece
- 33 -
III
(2) Cancel Rotation Restriction
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Rotation Stopper” using the key or the keyand then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Move the cursor to “OFF” using the key or the keyand then press the [ ] key.
ROTATION STOPPER
Current setting:ON
ON OFF
4 A confirmation message appears.
Press the [ ] key.
To cancel, move the cursor to “NO” using the key or the key and then press the [ ] key.
ROTATION STOPPER
Current setting:ON
ON OFF
Rotation stopper OFF ?
Yes No
5 When the cancellation is accepted, a “Complete!” messageappears and remains displayed for about one second.
ROTATION STOPPER
Current setting:OFF
ON OFF
Complete!
6 Press the MODE key to end the setting and to return to theOPERATION screen.
IV Other Operations
1 Operating LCD Backlight
- 34 -
IVOther Operations
1 Operating LCD Backlight
(1) Turning Backlight ON/OFF
Press the LCD ON/OFF key to turn the backlight ON orOFF.
LED INDICATION:
ON OFFGreen Orange
(2) Adjusting Brightness of Backlight
Press the DIA Bright/Dark key to adjust the brightness ofthe backlight.
IV Other Operations
2 Adjusting LCD Contrast
- 35 -
IV
2 Adjusting LCD Contrast
1 To adjust the contrast of the LCD, first remove the rearpanel of the remote control pad, then set DIP switch No. 9to ON.
2 Press the DIA Bright/Dark key to adjust the contrast, justlike adjusting backlight brightness.
3 After completing the adjustment, set DIP switch No. 9 toOFF and reattach the rear panel to the remote control pad.
V Operation and Indication Functions
1 Changing Operation Mode of Fine Focus Knob
- 36 -
VOperation and Indication Functions
1 Changing Operation Mode of Fine Focus Knob
Change the operation mode of the fine focus knob used for up/down focus motion.
[Operation Mode and the travel distance]
Coarse = 100 µm/rot. Middle = 50 µm/rot. Fine = 25 µm/rot.
The fine focus knob is set to the coarse mode by default.
Note:
The travel distance per rotation of the fine focus knob in each operation mode is a rough guide; precise accuracy isnot guaranteed. The travel distance will vary, depending on the speed at which the fine focus knob is turned.When the TE2000-U or the TE2000-S is used, the up/down focus motion cannot be controlled electrically and youcannot change the operation mode.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Fine Focus Knob” using the key or the keyand then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Select a travel distance (operation mode) using the PREVor NEXT key.
FINE FOCUS KNOB
[ 25]μm/rot.
4 Press the MODE key to end the setting and to return to theOPERATION screen.
V Operation and Indication Functions
2 Setting Indication on Operation Screen
- 37 -
V
2 Setting Indication on Operation Screen
The OPERATION screen indicates a variety of information, such as the current electrical component positions andinformation on the currently attached optical members.
This function turns indication of such information ON or OFF.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Remote Control Pad” using the key or the key and then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Turn indication of the information for the objective ON orOFF using the PREV or NEXT key.
REMOTE CONTROL PAD
DisplayObjective :[ON ]Condenser :[ON ]Filter :[ON ]Exciter :[ON ]Barrier :[ON ]
DIA Lamp :[ON ]Z-Position :[ON ]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
4 Select an item using the key or the key and turnindication ON or OFF using the PREV or NEXT key.Repeat this step to set all of the items for which you wantto edit settings.
REMOTE CONTROL PAD
DisplayObjective :[OFF]Condenser :[ON ]Filter :[ON ]Exciter :[ON ]Barrier :[ON ]
DIA Lamp :[ON ]Z-Position :[ON ]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
5 Press the MODE key to end settings and to return to theOPERATION screen.
V Operation and Indication Functions
3 Setting Buzzer ON/OFF
- 38 -
3 Setting Buzzer ON/OFF
Turn ON or OFF the buzzer confirmation that sounds when a key is pressed.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Remote Control Pad” using the key or the key and then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Move the cursor to “Buzzer” using the key or the key.
Turn the buzzer ON or OFF using the PREV or NEXT key.
REMOTE CONTROL PAD
DisplayObjective :[ON ]Condenser :[ON ]Filter :[ON ]Exciter :[ON ]Barrier :[ON ]
DIA Lamp :[ON ]Z-Position :[ON ]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
4 Press the MODE key to end the setting and to return to theOPERATION screen.
Note:Even if the buzzer is set to “ON.”, when the remote control is set to “OFF”, the buzzer won’t sound when a key ispressed on the OPERATION screen.
V Operation and Indication Functions
4 Setting Remote Control ON/OFF
- 39 -
V
4 Setting Remote Control ON/OFF
Turn remote-control operation of the electrical components using the remote control pad ON or OFF.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Remote Control Pad” using the key or the key and then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Move the cursor to “Remote Control” using the key orthe key.
Turn remote-control operation ON or OFF using the PREVor NEXT key.
REMOTE CONTROL PAD
DisplayObjective :[ON ]Condenser :[ON ]Filter :[ON ]Exciter :[ON ]Barrier :[ON ]
DIA Lamp :[ON ]Z-Position :[ON ]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
4 Press the MODE key to end the setting and to return to theOPERATION screen.
V Operation and Indication Functions
5 Turning ON/OFF LED with LCD ON/OFF Key
- 40 -
5 Turning ON/OFF LED with LCD ON/OFF Key
Enable the LCD ON/OFF key to turn the LED ON or OFF.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Remote Control Pad” using the key or the key and then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Move the cursor to “LCD” using the key or the key.
Select “OFF” using the PREV or NEXT key.
If “OFF” is selected, when the LCD backlight is turned offwith LCD ON/OFF key, the LED is also turned OFF. The“LCD” is set to “ON” by default.
REMOTE CONTROL PAD
DisplayObjective :[ON ]Condenser :[ON ]Filter :[ON ]Exciter :[ON ]Barrier :[ON ]
DIA Lamp :[ON ]Z-Position :[ON ]
Buzzer :[ON ]
Remote Control:[ON ]
LCD :[OFF]
4 Press the MODE key to end the setting and to return to theOPERATION screen.
V Operation and Indication Functions
6 Setting Communications Delimiter of External Device
- 41 -
V
6 Setting Communications Delimiter of External Device
Set the delimiter for communications between the HUB controller and an external device.
[Delimiter]
CR LF
CR is selected by default.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “More” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Communication Delimiter” using the key or the key and then press the [ ] key.
MORERotation Stopper
Fine Focus Knob
Other Unit
Remote Control Pad
Shutter Key
Foot Switch
Communication Delimiter
3 Move the cursor using the key or the key to select“CR” or “LF.”
Note:Check the communications delimiter with the instructionmanual of the external device.
COMMUNICATION DELIMITERFOR EXTERNAL UNIT
CR LF
4 Press the MODE key to end the setting and to return to theOPERATION screen.
V Operation and Indication Functions
7 Registering Data for Optical Members
- 42 -
7 Registering Data for Optical Members
(1) Objective
You can register optional data for up to nine objectives.
If an attached objective is not listed in the presets, register the objective.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Objective” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Edit” using the key or the key and then pressthe [ ] key.
OBJECTIVESeries Mag.
1[P Fluor ][DL 4x ]
2[P Fluor ][DL 10x ]
3[P Fluor ][ELWD DM 20x ]
4[P Fluor ][ELWD DM 40x ]
5[P Fluor ][ELWD DLL 60x ]
6[P Fluor ][DLL 100x ]
Edit
3 Select one location out of nine locations to register theoptional data using the PREV or NEXT key.
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[――――――――――]
Mag. :[0 ]x
N.A. :[0 ]
W.D. :[0 ]
Type :[――――――――――]
4 Move the cursor to “Series” using the key or the key.
Select the series of the objective using the PREV or NEXTkey.
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[Other ]
Mag. :[1 ]x
N.A. :[0。001]
W.D. :[0。01 ]
Type :[dry ]
5 Move the cursor to “Mag.” using the key or the key.
Select the magnification of the objective using the PREVor NEXT key.
If no entry is made in “Series” (indicated as “--------”), thecursor will not move to “Mag.”
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[Other ]
Mag. :[10 ]x
N.A. :[0。001]
W.D. :[0。01 ]
Type :[dry ]
6 Move the cursor to “N.A.” using the key or the key.
Enter the numerical aperture using the numerical keys andthe key or the key within the range between 0.001and 2.000.
If the entry exceeds the upper limit or falls below the lowerlimit, the N.A. is automatically set to the upper or lowerlimit.
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[Other ]
Mag. :[10 ]x
N.A. :[0.25 ]
W.D. :[0。01 ]
Type :[dry ]
V Operation and Indication Functions
7 Registering Data for Optical Members
- 43 -
V
7 Move the cursor to “W.D.” using the key or the key.
Using the numerical keys and the key or the key,enter the working distance within the range between 0.01and 40.00.
If the entry exceeds the upper limit or falls below the lowerlimit, the W.D. is automatically set to the upper or lowerlimit.
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[Other ]
Mag. :[10 ]x
N.A. :[0.25 ]
W.D. :[6.2 ]
Type :[dry ]
8 Move the cursor to “Type” using the key or the key.
Select the type of objective using the PREV or NEXT key.
EDIT OBJECTIVE DATA
Location:[Other1]
Series :[Other ]
Mag. :[10 ]x
N.A. :[0.25 ]
W.D. :[6.2 ]
Type :[dry ]
9 To continue registration of optional data, move the cursorto “Location” using the key or the key and repeatsteps 3 - 8 above.
EDIT OBJECTIVE DATA
Location:[Other2]
Series :[――――――――――]
Mag. :[0 ]x
N.A. :[0 ]
W.D. :[0 ]
Type :[――――――――――]
10 Press the MODE key to end the setting and to return to theOPERATION screen.
To delete registered data
1) Move the cursor to “Location” using the key or the key and select data to delete using PREV or NEXTkey.
2) Press CLR key.
V Operation and Indication Functions
7 Registering Data for Optical Members
- 44 -
(2) Condenser Module
You can register optional data for up to nine condenser modules.
If an attached condenser module is not listed in the presets, register the condenser module.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Condenser” using the key or the key andthen press the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Edit” using the key or the key and then pressthe [ ] key.
CONDENSERName
1[BF ]
2[PhL ]
3[Ph1 ]
4[Ph2 ]
5[Ph3 ]
Edit
3 Select one location out of nine locations to register theoptional data using the PREV or NEXT key.
EDIT CONDENSER DATA
Location:[Other1]
Name :[ ]
4 Move the cursor to “Name” using the key or the key.
Using the numerical/alphabetical keys and the key orthe key, type in the name of the condenser module.
You can type in up to 10 characters.
EDIT CONDENSER DATA
Location:[Other1]
Name :[ABC ]
5 To continue registration of optional data, move the cursorto “Location” using the key or the key and repeatsteps 3 and 4 above.
EDIT CONDENSER DATA
Location:[Other2]
Name :[ ]
6 Press the MODE key to end the setting and to return to theOPERATION screen.
To delete registered data
1) Move the cursor to “Location” using the key or the key and select data to delete using PREV or NEXTkey.
2) Press CLR key.
V Operation and Indication Functions
7 Registering Data for Optical Members
- 45 -
V
(3) Filter Block
You can register optional data for up to nine filter blocks.
If an attached filter block is not listed in the presets, register the filter block.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Filter” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Edit” using the key or the key and then pressthe [ ] key.
FILTERName
1[UV-1A ] EX : EX365/10
2[V-1A ] DM : DM400
3[BV-1A ] BA : BA400
4[B-1A ]
5[G-1A ]
6[DIA ]
Edit
3 Select one location out of nine locations to register theoptional data using the PREV or NEXT key.
EDIT FILTER DATA
Location:[Other1]
Name :[ ]
EX :[――――――――――]Edit
DM :[――――――――――]Edit
BA :[――――――――――]Edit
4 Move the cursor to “Name” using the key or the key.
Type in the name of the filter block using thenumerical/alphabetical keys and the key or the key.
You can type in up to 10 characters.
EDIT FILTER DATA
Location:[Other1]
Name :[ABC ]
EX :[――――――――――]Edit
DM :[――――――――――]Edit
BA :[――――――――――]Edit
5 Move the cursor to “EX” using the key or the key.
Select an excitation filter of the filter block using the PREVor NEXT key.
If the excitation filter is not listed in the presets, register theoptional data for the excitation filter.
To register the optional data, move to “Edit” using the key or the key and then press the key.
For details, see steps 3 forward for V-7 (5) ExcitationFilter.
EDIT FILTER DATA
Location:[Other1]
Name :[ABC ]
EX :[EX365/10 ]Edit
DM :[――――――――――]Edit
BA :[――――――――――]Edit
6 Move the cursor to “DM” using the key or the key.
Select a dichroic mirror for the filter block using the PREVor NEXT key. If the dichroic mirror is not listed in thepresets, register the optional data for the dichroic mirror.
To register the optional data, move to “Edit” using the key or the key and then press the key.
For details, see V-7 (4) Dichroic Mirror.
EDIT FILTER DATA
Location:[Other1]
Name :[ABC ]
EX :[EX365/10 ]Edit
DM :[DM400 ]Edit
BA :[――――――――――]Edit
V Operation and Indication Functions
7 Registering Data for Optical Members
- 46 -
7 Move the cursor to “BA” using the key or the key.
Select a barrier filter for the filter block using the PREV orNEXT key. If the barrier filter is not listed in the presets,register the optional data for the barrier filter.
To register the optional data, move to “Edit” using the key or the key and then press the key.
For details, see steps from 3 forward of V-7 (6) BarrierFilter.
EDIT FILTER DATA
Location:[Other1]
Name :[ABC ]
EX :[EX365/10 ]Edit
DM :[DM400 ]Edit
BA :[BA400 ]Edit
8 To continue registration of optional data, move the cursorto “Location” using the key or the key and repeatsteps 3 - 7 above.
EDIT FILTER DATA
Location:[Other2]
Name :[ ]
EX :[――――――――――]Edit
DM :[――――――――――]Edit
BA :[――――――――――]Edit
9 Press the MODE key to end the setting and to return to theOPERATION screen.
To delete registered data
1) Move the cursor to “Location” using the key or the key and select data to delete using PREV or NEXTkey.
2) Press CLR key.
V Operation and Indication Functions
7 Registering Data for Optical Members
- 47 -
V
(4) Dichroic Mirror
You can register optional data for up to nine dichroic mirrors.
If an attached dichroic mirror is not listed in the presets, register the dichroic mirror.
1 Select “Edit” using the key or the key and then pressthe [ ] key.
EDIT FILTER DATA
Location:[Other1]
Name :[ABC ]
EX :[EX365/10 ]Edit
DM :[DM400 ]Edit
BA :[――――――――――]Edit
2 Select one location out of nine locations to register theoptional data using the PREV or NEXT key.
EDIT DM DATA
Location:[Other1]
Name :[ ]
3 Move the cursor to “Name” using the key or the key .
Using the numerical/alphabetical keys and the key orthe key, type in the wavelength of the dichroic mirror.You can type in up to 10 characters.
EDIT DM DATA
Location:[Other1]
Name :[DM410 ]
4 To continue registration of optional data, move the cursorto “Location” using the key or the key and repeatsteps 2 and 3 above.
EDIT DM DATA
Location:[Other2]
Name :[ ]
5 Press the MODE key to end the setting and to return to theOPERATION screen.
To delete registered data
1) Move the cursor to “Location” using the key or the key and select data to delete using PREV or NEXTkey.
2) Press CLR key.
V Operation and Indication Functions
7 Registering Data for Optical Members
- 48 -
(5) Excitation Filter
You can register optional data for up to nine excitation filters.
If an attached excitation filter is not listed in the presets, register the excitation filter.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Exciter” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Edit” using the key or the key and then pressthe [ ] key.
EXCITER
Name1[EX465-495 ]5[――――――――――]
2[EX460-500 ]6[――――――――――]
3[――――――――――]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
3 Select a location to register the optional data using thePREV or NEXT key.
EDIT EX DATA
Location:[Other1]
Name :[ ]
4 Move the cursor to “Name” using the key or the key .
Using the numerical/alphabetical keys and the key orthe key, type in the wavelength of the excitation filter.You can type in up to 10 characters.
EDIT EX DATA
Location:[Other1]
Name :[EX350-380 ]
5 To continue registration of optional data, move the cursorto “Location” using the key or the key and repeatsteps 3 and 4 above.
EDIT EX DATA
Location:[Other2]
Name :[ ]
6 Press the MODE key to end the setting and to return to theOPERATION screen.
To delete registered data
1) Move the cursor to “Location” using the key or the key and select data to delete using PREV or NEXTkey.
2) Press CLR key.
V Operation and Indication Functions
7 Registering Data for Optical Members
- 49 -
V
(6) Barrier Filter
You can register optional data for up to nine barrier filters.
If an attached barrier filter is not listed in the presets, register the barrier filter.
1 Press the MODE key, and the SETTING MENU screen willappear on the LCD.
Select “Barrier” using the key or the key and thenpress the [ ] key.
SETTING MENUObjective
Condenser
Filter
Exciter
Barrier
Combination(Obj.>Condenser)
Combination(Filter>EX/BA)
More
2 Select “Edit” using the key or the key and then pressthe [ ] key.
BARRIER
Name1[BA515-555 ]5[――――――――――]
2[BA510 ]6[――――――――――]
3[BA510-560 ]7[――――――――――]
4[――――――――――]8[DIA ]
Edit
3 Select one location out of nine locations to register theoptional data using the PREV or NEXT key.
EDIT BA DATA
Location:[Other1]
Name :[ ]
4 Move the cursor to “Name” using the key or the key.
Using the numerical/alphabetical keys and the key orthe key, type in the wavelength of the barrier filter.You can type in up to 10 characters.
EDIT BA DATA
Location:[Other1]
Name :[BA410 ]
5 To continue registration of optional data, move the cursorto “Location” using the key or the key and repeatsteps 3 and 4 above.
EDIT BA DATA
Location:[Other2]
Name :[ ]
6 Press the MODE key to end the setting and to return to theOPERATION screen.
To delete registered data
1) Move the cursor to “Location” using the key or the key and select data to delete using PREV or NEXTkey.
2) Press CLR key.
VI Maintenance Menu
1 Indicating Program Version and Checksum
- 50 -
VIMaintenance Menu
1 Indicating Program Version and Checksum
Indicate the program version of the remote control pad and the HUB controller and the checksum on the LCD.
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
2 Press the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
3 The program versions and the checksum appear on theLCD.
VERSION
T-RCP REMOTE CONTROL PADV1.00 Sum1234h
T-HUBC HUB CONTROLLERMAIN-cpu: V1.00 Sum5678hSUB-cpu : V1.00 SumABCDh
4 Press the MODE key to return to the OPERATION screen.
VI Maintenance Menu
2 Testing Electrical Component Operations
- 51 -
VI
2 Testing Electrical Component Operations
Test the operations of the electrical components connected to the HUB controller.
There are two test modes.
All-test mode: Test all the electrical components connected.
Individual test mode: Select a component and test the component.
(1) All-Test Mode
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, pressthe MODE key.
Select “TEST 1” using the key or the key and releasethe [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 On the TEST 1 screen, the arrow “→” is pointed at “All-Test.” Press the [ ] key.
“→” moves to “OBJECTIVE” and the test will begin.
TEST1 1/5→ ALL TEST
OBJECTIVE 1 [ ] 2 [ ] 3 [ ] 4 [ ] 5 [ ] 6 [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select item and press enter to start.
3 The test results are indicated in [ ] as “OK” or “NG.” TEST1 1/5 ALL TEST
→ OBJECTIVE 1 [OK ] 2 [ ] 3 [ ] 4 [ ] 5 [ ] 6 [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
VI Maintenance Menu
2 Testing Electrical Component Operations
- 52 -
4 After the test of one component is completed, “→” movesto the next component and the test of the component willbegin.The components not connected to the HUB controller willbe skipped.
TEST1 2/5
EPI-FILTER 1 [OK] 2 [OK] 3 [OK] 4 [OK] 5 [OK] 6 [OK]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
TEST1 3/5
LIGHT PATH 1 [OK] 2 [OK] 3 [OK] 4 [OK] 5 [OK] CONDENSER Right [OK] Left [OK]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
TEST1 4/5
EXCITER Right [ ] Left [ ] BARRIER Right [ ] Left [ ]
ANALYZER [OK]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
5 When all the components have been tested, “Complete!”appears and remains displayed for about one second.
TEST1 5/5
DIA LAMP REMOTE [OK] ON/OFF [OK] ADJ-up [OK] ADJ-down [OK]→ Shutter A [OK] B [OK]
CAMERA EXP. [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
6 Press the MODE key to return to the OPERATION screen.
How to interrupt the all-test
Press the [ ] key to interrupt the test.
When the test is interrupted, the following message appears after the test of the currently tested component iscompleted.
Press enter to restart.
To resume the test, press the [ ] key again.
How to end the all-test midway
Press the [ ] key to interrupt the test.
Press the MODE key.
How to check test results again
Move “→” using the key or the key to change screens.
This operation is also available while the test is interrupted.
VI Maintenance Menu
2 Testing Electrical Component Operations
- 53 -
VI
(2) Individual Test Mode
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “TEST 1” using the key or the key and pressthe [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 Move “→” using the key or the key to select anelectrical component to test.
Press the [ ] key.
The test of the selected component begins.If a component is not connected to the HUB controller, youcannot select the component.
TEST1 1/5 ALL TEST
→ OBJECTIVE 1 [ ] 2 [ ] 3 [ ] 4 [ ] 5 [ ] 6 [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
TEST1 2/5
EPI-FILTER 1 [ ] 2 [ ] 3 [ ] 4 [ ] 5 [ ] 6 [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
TEST1 3/5
LIGHT PATH 1 [ ] 2 [ ] 3 [ ] 4 [ ] 5 [ ] CONDENSER Right [ ] Left [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
TEST1 4/5
EXCITER Right [ ] Left [ ] BARRIER Right [ ] Left [ ]
ANALYZER [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
TEST1 5/5
DIA LAMP REMOTE [ ] ON/OFF [ ] ADJ-up [ ] ADJ-down [ ] Shutter
A [ ] B [ ]
CAMERA EXP. [ ]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running ALL TEST... Press enter to pause.
3 When the test is completed, “Complete!” appears andremains displayed for about one second.
TEST1 1/5 ALL TEST
→ OBJECTIVE 1 [OK] 2 [OK] 3 [OK] 4 [OK] 5 [OK] 6 [OK]
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
4 Press the MODE key to return to the OPERATION screen.
How to check test results again
Move “→” using the key or the key to change screens.
VI Maintenance Menu
3 Testing Hardware of Remote Control Pad
- 54 -
3 Testing Hardware of Remote Control Pad
The following tests are available to evaluate the hardware of the remote control pad.
Key input test Checks to see if the input of each key is read correctlyLED ON/OFF test Checks to see if all the LEDs are controlled correctlyLCD indication test Checks to see if the LCD indication is controlled correctly and tests the quality of the LCD
(1) Key Input Test
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “TEST 2” using the key or the key and pressthe [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 Move “→” using the key or the key to select “KEY.”
Press the [ ] key.
3 Press the keys (except the [ ] key) one by one.
When the input for a key is read correctly, the key positionin the key layout on the screen will be indicated in black.
4 Press the [ ] key to end the key input test.
5 Press the MODE key to return to OPERATION screen.
VI Maintenance Menu
3 Testing Hardware of Remote Control Pad
- 55 -
VI
(2) LED ON/OFF Test
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “TEST 2” using the key or the key and pressthe [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 Move “→” using the key or the key to select “LED.”
Press the [ ] key. The LED ON/OFF test will begin.
All the LEDs light green and then go out one by one inintervals of about 0.5 seconds, except that the ANALYZERIN/OUT key and LCD ON/OFF key light green, turn toorange, and then go out.
3 Press the [ ] key to end the LED ON/OFF test.
4 Press the MODE key to return to OPERATION screen.
(3) LCD Indication Test
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “TEST 2” using the key or the key and pressthe [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 Move “→” using the key or the key to select “LCD.”
Press the [ ] key. The LCD indication test will begin.
The whole screen turns black and then white repeatedly atintervals of about 3 seconds.
3 Press the [ ] key to end the LCD indication test.
4 Press the MODE key to return to OPERATION screen.
VI Maintenance Menu
4 Initializing Focus Motion Potentiometer
- 56 -
4 Initializing Focus Motion Potentiometer
The potentiometer can be initialized at each reference point to detect absolute position of the focusing mechanism.
Use this function after changing the combination of the microscope and HUB controller.
Initialization takes about 3 minutes to be completed. During initialization, never touch the coarse or fine focusknobs.
1 Remove the rear panel of the remote control pad and setDIP switch No.8 to ON.
2 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “TEST 2” using the key or the key and pressthe [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
3 After the TEST 2 screen appears, press the Z-AXI. RESETkey.
Initialization of the focus motion potentiometer begins.
The initialization takes about 3 minutes at maximum.
4 When the initialization is completed, a “Complete!”message appears and remains displayed for about onesecond.Also, the HUB controller sounds the buzzer.
Note:The buzzer sounds as follows:
Upon normal completion: a peepUpon failure of normal completion: four peepings
5 Turn off the power to the HUB controller.
Set DIP switch No.8 to OFF and reattach the rear panel tothe remote control pad.
Use the coarse focus knob to lower the focusingmechanism 2 to 3 mm, then turn on the HUB controller.
Turning the coarse focus knob halfway lowers the focusingmechanism about 2.5 mm.
Note:After initialization, the focusing mechanism islocated at the highest position.
VI Maintenance Menu
5 Resetting Remote Control Pad Settings to Default Values
- 57 -
VI
5 Resetting Remote Control Pad Settings to Default Values
Use this function to reset the settings stored in the memory of the remote control pad back to the default values(See Table 1).
The settings of the LCD brightness and contrast are also reset to their default values.
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “PAD Data” using the key or the key andpress the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the[ ] key.
If you select “No” and press the [ ] key, the display willreturn to the MAINTENANCE MENU screen.
PAD DATA
Initialize PAD data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press enter to start.
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
PAD DATA
Initialize PAD data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
[Table 1] Settings Stored in Remote Control Pad Memory and Default Settings
Menu option Default settingSETTING MENU → More → Remote Control PadDisplay Objective ON
Condenser ONFilter ONExciter ONBarrier ONDIA Lamp ON
LCD ON
VI Maintenance Menu
6 Resetting HUB Controller Settings to Default Values
- 58 -
6 Resetting HUB Controller Settings to Default Values
Use this function to reset the data stored in the memory of the HUB controller back to the default values. Forexample, the memory stores information on the attached objectives, registered optional data of optical members,and information on the interlocking of the revolving nosepiece and the condenser module changeover (See Table2).
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “HUB Data” using the key or the key andpress the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
HUB DATA
Initialize HUB data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press enter to start.
3 When the following message appears, turn on the poweragain.
“Please re-switch on a power supply.”
HUB DATA
Initialize HUB data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Running...
[Table 2] Settings Stored in HUB Controller Memory and Default Settings
Menu option Default settingSETTING MENU
Addresses 16 Not attachedObjectiveOptional data Not registeredAddresses 15 Not attachedCondenserOptional data Not registeredAddresses 16 Not attachedOptional data (filter block) Not registered
Filter
Optional data (dichroic mirror) Not registeredAddresses 18 Not attachedExciterOptional data (excitation filter) Not registeredAddresses 18 Not attachedBarrierOptional data (barrier filter) Not registered
Combination(OBJ.>... Addresses 16 Not interlockedCombination(Filter. Addresses 16 Not interlocked
VI Maintenance Menu
7 Reset Control Data to Default Values
- 59 -
VI
7 Reset Control Data to Default Values
Use this function to reset the control data stored in the memory of the HUB controller to their default values. Usethis function when an electrical component doesn’t work properly or has been replaced with a new component.
The control data of the electrical components are initialized either in batches or individually. After replacing anelectrical component, initialize the control data of the replaced component only.
(1) All Components
When the control data of all the electrical components are initialized in batches, the settings in the table below willalso be initialized.
[Table 3]
Menu option Default settingSETTING MENU → MoreRotation Stopper OFFFine Focus Knob Coarse = 100 µmOther Unit OFF
Display Z-Position OFFBuzzer ON
Remote Control Pad
Remote Control ONShutter A OFFShutter KeyShutter B OFF
Foot Switch UnusedCommunication... CR
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “All Control Data” using the key or the key andpress the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the[ ] key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize all control data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
VI Maintenance Menu
7 Reset Control Data to Default Values
- 60 -
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize all control data ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
(2) Revolving Nosepiece
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “Revolving Nosepiece” using the key or the key and press the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the[ ] key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize control data for revolving nosepiece ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize control data for revolving nosepiece ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
VI Maintenance Menu
7 Reset Control Data to Default Values
- 61 -
VI
(3) Condenser Module
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “Condenser Module (Cassette)” using the key orthe key and press the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the[ ] key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize control data for condenser cassette ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize control data for condenser cassette ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
VI Maintenance Menu
7 Reset Control Data to Default Values
- 62 -
(4) Optical Path
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “Light Path” using the key or the key andpress the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the[ ] key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize control data for light path ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize control data for light path ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
VI Maintenance Menu
7 Reset Control Data to Default Values
- 63 -
VI
(5) Filter Block
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “Filter Block” using the key or the key andpress the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the [ ]key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize control data for filter block ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize control data for filter block ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
VI Maintenance Menu
7 Reset Control Data to Default Values
- 64 -
(6) Excitation Filter
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “Exciter Filter” using the key or the key andpress the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize control data for exciter filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize control data for exciter filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
VI Maintenance Menu
7 Reset Control Data to Default Values
- 65 -
VI
(7) Barrier Filter
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “Barrier Filter” using the key or the key andpress the [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize control data for barrier filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize control data for barrier filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
VI Maintenance Menu
7 Reset Control Data to Default Values
- 66 -
(8) Auxiliary Filter
1 Turn on the power to the HUB controller while holdingdown the MODE key.
After the MAINTENANCE MENU screen appears, releasethe MODE key.
Select “AUX Filter” using the key or the key and pressthe [ ] key.
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
2 A confirmation message appears.
Select “Yes” using the key or the key and press the key.
If you select “No” and press the key, the display willreturn to the MAINTENANCE MENU screen.
CONTROL DATA
Initialize control data for AUX filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Select Yes and press ENTER to start。
3 When the initialization is completed, “Complete!” appearsand remains displayed for about one second. TheMAINTENANCE MENU screen then appears.
CONTROL DATA
Initialize control data for AUX filter ?
Yes No
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Complete!
MAINTENANCE MENU
1.Version2.TEST13.TEST24.PAD Data5.HUB Data6.Control Data
a.All Control Datab.Revoiving Nosepiecec.Condenser Cassetted.Light Pathe.Filter Blockf.Exciter Filterg.Barrier Filterh.AUX Filter
VII Troubleshooting
1 Remote control pad doesn’t start up. (Title screen appears, and the screen freezes.)
- 67 -
VII
VIITroubleshooting
1 Remote control pad doesn’t start up. (TITLE screen appears,and the screen freezes.)
Cause Action
The remote control pad is not connected to theHUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the remotecontrol pad from the HUB controller and connect it again.See “Introduction-3 Connection of Remote Control Pad and HUBController.”
2 Electrical component doesn’t operate.
Cause Action
The electrical component is not connected to theHUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the electricalcomponent from the HUB controller and connect it again.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
The remote control operation is set to “OFF.”Set the remote control operation to “ON.”See “V-4 Setting Remote Control ON/OFF.”
3 Revolving nosepiece doesn’t rotate at a certain position ofthe fine focus knob.
Cause Action
The revolving nosepiece rotation is restricted.Cancel the rotation restriction.See “III-3 Restricting Rotation of Revolving nosepiece.”
4 Dia-illumination lamp cannot be turned ON or OFF.
Cause Action
The dia-illumination lamp power supply is notconnected to the HUB controller correctly.
Turn OFF the power of the HUB controller. Disconnect the dia-illuminationlamp power supply from the HUB controller and connect it again.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
EXTERNAL switch of the dia-illumination lamppower supply is OFF.
Turn ON the EXTERNAL switch of the dia-illumination lamp power supply.See “I-1 (2) Turning ON EXTERNAL Switch of Dia-Illumination LampPower Supply.”
The remote control operation is set to “OFF.”Set the remote control operation to “ON.”See “V-4 Setting Remote Control ON/OFF.”
VII Troubleshooting
5 Voltage of dia-illumination lamp cannot be adjusted.
- 68 -
5 Voltage of dia-illumination lamp cannot be adjusted.
Cause Action
The dia-illumination lamp power supply is notconnected to the HUB controller correctly.
Turn OFF the power of the HUB controller. Disconnect the dia-illumination lamp power supply from the HUB controller and connect itagain.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
EXTERNAL switch of the dia-illumination lamppower supply is OFF.
Turn ON the EXTERNAL switch of the dia-illumination lamp power supply.See “I-1 (2) Turning ON EXTERNAL Switch of Dia-Illumination LampPower Supply.”
The remote control operation is set to “OFF.”Set the remote control operation to “ON.”See “V-4 Setting Remote Control ON/OFF.”
The dia-illumination lamp is OFF.Turn ON the dia-illumination lamp.See “II-9 (1) Turning Lamp ON/OFF.”
6 Opening/closing status of Uniblitz shutter doesn’t coincidewith LED indication.
Cause ActionThe Uniblitz shutter controller is not in the N.C.mode.
Place the Uniblitz shutter controller into N.C. mode.See “I-1 (3) Placing Uniblitz Shutter Controller into N.C. Mode.”
7 Objective information is not indicated.
Cause Action
The revolving nosepiece is not connected to theHUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the revolvingnosepiece from the HUB controller and connect it again.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
Indication of information for the objective is OFF.Turn ON the indication function for the information on the objective.See “V-2 Setting Indication on Operation Screen.”
8 Condenser module information is not indicated.
Cause Action
The condenser module changeover is notconnected to the HUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the condensermodule changeover from the HUB controller and connect it again.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
Indication of the information for the condensermodule is OFF.
Turn ON the indication function for the information on the condensermodule.See “V-2 Setting Indication on Operation Screen.”
9 Filter block information is not indicated.
Cause Action
The filter block changeover is not connected to theHUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the filter blockchangeover from the HUB controller and connect it again.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
Indication of the information for the filter block isOFF.
Turn ON the indication function for the information for the filter block.See “V-2 Setting Indication on Operation Screen.”
VII Troubleshooting
10 Excitation filter information is not indicated.
- 69 -
VII
10 Excitation filter information is not indicated.
Cause Action
The excitation filter changeover is not connected tothe HUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the excitationfilter changeover from the HUB controller and connect it again.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
Indication of the information for the excitation filteris OFF.
Turn ON the indication function for the information on the excitation filter.See “V-2 Setting Indication on Operation Screen.”
11 Barrier filter information is not indicated.
Cause Action
The barrier filter changeover is not connected to theHUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the barrier filterchangeover from the HUB controller and connect it again.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
Indication of the information for the barrier filter isOFF.
Turn ON the indication function for the information on the barrier filter.See “V-2 Setting Indication on Operation Screen.”
12 Dia-illumination lamp voltage is not indicated.
Cause Action
The dia-illumination lamp power supply is notconnected to the HUB controller correctly.
Turn OFF the power to the HUB controller. Disconnect the dia-illumination lamp power supply from the HUB controller and connect itagain.See “I-1 (1) Connecting Electrical Components to HUB Controller.”
The EXTERNAL switch of the dia-illumination lamppower supply is OFF.
Turn ON the EXTERNAL switch of the dia-illumination lamp power supply.See “I-1 (2) Turning ON EXTERNAL Switch of Dia-Illumination LampPower Supply.”
The remote control operation is set to “OFF.”Set the remote control operation to “ON.”See “V-4 Setting Remote Control ON/OFF.”
13 Z-axis coordinates are not indicated.
Cause ActionThe HUB controller is not connected to themicroscope correctly.
Turn OFF the power to the HUB controller.Check that the HUB controller is correctly connected to the microscope.
Indication of z-axis coordinates is OFF.Turn ON the indication function for z-axis coordinates.See “V-2 Setting Indication on Operation Screen.”
14 Buzzer doesn’t sound when a key is pressed.
Cause Action
The buzzer is OFF.Turn the buzzer ON.See “V-3 Setting Buzzer ON/OFF.”