Solar Water Heating Systems
Direct
Indirect
Active
Passive
![Page 2: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/2.jpg)
System Types
ActiveUses a pump, fan, or other powered device
PassiveDoes not use a pump or fan - relies on natural forces “Gravity & density”
![Page 3: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/3.jpg)
Major System Components
•Active System•Collector(s) •Storage tank•Controller•Pump or Circulator
•Passive System•Collector(s)•Storage tank
![Page 4: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/4.jpg)
System Types
DirectCity or potable water is circulated from the tank to the collector and back
IndirectFluid circulating through the collector never comes in contact with the city or potable water in the storage tankA heat exchanger is used to transfer heat from the circulating fluid to the potable water
![Page 5: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/5.jpg)
Solar Hot Water System Types
Direct Indirect
![Page 6: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/6.jpg)
System Components
Heat Collection and TransferHeat Storage - Vertical or HorizontalHeat Delivery - Pump or CirculatorFreeze Protection - If requiredControlsValves
![Page 7: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/7.jpg)
System Components
Collectors
![Page 8: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/8.jpg)
SOLAR COLLECTORS
Low- 70O F to 105O F21O C to 40.5O C
Medium- 105O F to 200O F40.5O C to 93O C
High- 180O F to 400O F80O C to 200O C
![Page 9: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/9.jpg)
System Components
CollectorCollects the Solar EnergyHeart of the SystemDominant types of collectors:
Flat Plate Solar CollectorIntegral Collector Storage (ICS)BatchConcentrating
![Page 10: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/10.jpg)
Low Temperature Collectors
![Page 11: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/11.jpg)
Low Temperature
Unglazed or metal absorbers
PlasticPolypropyleneEPDMABSPolyethylene
![Page 12: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/12.jpg)
Extruded Polyethylene Plastics
![Page 13: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/13.jpg)
PVC schedule 40 PipeUV inhibitors
![Page 14: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/14.jpg)
Mid-Temperature Collectors
![Page 15: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/15.jpg)
Flat Plate Copper Collector
![Page 16: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/16.jpg)
Collector Components
Absorber &Flow tubes
Enclosure
Glazing
Insulation
Inlet tube
Outlet tube
Flat Plate Collector
![Page 17: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/17.jpg)
Side view at header
Glass
Insulation
FintubeHeader
![Page 18: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/18.jpg)
Corner bracket
GlassAluminum Back-sheet
Rivets
Extruded Aluminum frame-wallSilicone grommets
Copper Header
Collector Components
![Page 19: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/19.jpg)
Heat Pipe Evacuated Tube
![Page 20: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/20.jpg)
Heat Pipe
![Page 21: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/21.jpg)
Heat Pipe
![Page 22: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/22.jpg)
![Page 23: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/23.jpg)
![Page 24: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/24.jpg)
![Page 25: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/25.jpg)
![Page 26: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/26.jpg)
CPCConcentrating Parabolic Collector
![Page 27: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/27.jpg)
Receiver Tube with Non-Imaging Optical ReflectorConcentrating Parabolic Collector
![Page 28: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/28.jpg)
CPC
Concentrating Parabolic Collector
![Page 29: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/29.jpg)
Simple
Controls And Circulation Systems
![Page 30: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/30.jpg)
10k Sensor
Differential Controllers Typically Have Ability To Set Differential:
ON: Between 8 and 30 degreesOFF: Between 3 to 5 degrees
Differential Controllers
![Page 31: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/31.jpg)
RTD
New Controls May IncludeAbility To Meter Performance
![Page 32: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/32.jpg)
Building Automation ControlsProtocols:
Turn On DifferentialTurn Off DifferentialTank Overheating (Glycol)
Turn Pump On ---Run Continuously Until Temperature In Tank Drops To Acceptable Level
Could Have Pressure Monitor And Alarm
![Page 33: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/33.jpg)
Solar Water Heating SystemsDirectIndirect
GlycolDrain BackThermosyphon
Combi-Systems (Space Heating)Forced AirRadiant
Packaged Systems
![Page 34: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/34.jpg)
Direct System
• Fluid in tank isheated in collector
• Most common systemtemperate climates
Typically not used in cold or freezing climates
![Page 35: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/35.jpg)
Direct System
Circulates water from tank to collectorWater heated by collector and returned to tank
Stratification of warm water in tankDifferential controller regulates pump operationValvesFREEZE PROTECTION (may be required)
Freeze valve/manual DRAINDOWN
![Page 36: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/36.jpg)
Direct System
![Page 37: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/37.jpg)
Indirect System
•Non-potable fluid (usually glycol) circulates through collector and heat exchanger
•Freeze protection
•Reduced Scale
![Page 38: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/38.jpg)
Two Types of Indirect Systems
Difference Is Collector Loop
• Circulating Glycol – Pressurized Heat Transfer Fluid is Antifreeze Solution
• Drainback – Not Pressurized, Heat Transfer Fluid is Water
![Page 39: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/39.jpg)
Active Indirect Glycol System
Used where freezing or water quality is problem Anti-freeze is heat transfer solutionHeat exchanger
Internal or external to tankExpansion tank - for fluid thermal expansionFill and drain access valvesDifferential controller - ac pumpPhotovoltaic controller - dc pumpSimilar valves
Requires relief valves/ air vents
![Page 40: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/40.jpg)
Indirect Pressurized Glycol
Pros:Excellent freeze protectionCan be PV driven
Cons:Must inspect/replace glycol periodicallyCan be problems when used for space heating
![Page 41: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/41.jpg)
2KW 80-Gallon External Heat Exchanger with PV Pump and Control
Gas/LPG
Hot Water Heater
Solar Storage Tank
Cold In
Hot Out
Air vent
Expansion tank
Temperature & Pressure Gauge
Temperature Gauge
Pressure Relief Valve
Temperature & Pressure Relief
Valve
Check Valve
Ball Valve
Drain Valve
12 VDC Circulator
Tempering Valve
Coin Vent
Sensor
Differential Controller
Two tanks required for
Gas/LPG only
Electric element in 80-gallon
storage tank for systems with
electric back-up
![Page 42: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/42.jpg)
Indirect Advantage
Pressurized Glycol System
Freeze protection provided by antifreeze fluid. Collector loop remains full and pressurized.
Don’t have to overcome head losses, etc.Careful sloping of pipe not important.PV can be used to power pump.
![Page 43: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/43.jpg)
Indirect Disadvantages
Heat transfer properties of antifreeze fluids inferior to water - reduced performance –higher costsPeriodic maintenance required to ensure fluid properties have not deterioratedCollectors and antifreeze have to withstand stagnation when summer load is satisfied early in day
![Page 44: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/44.jpg)
Indirect Disadvantages
Venting through pressure/temperature relief valve under stagnation conditions
if excessive - will require refilling of system to proper operating pressure
Code requirements may require using a double wall heat exchanger and nontoxic freeze solution
![Page 45: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/45.jpg)
Indirect Pressurized Glycol
Demand Gas Heater
![Page 46: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/46.jpg)
Active IndirectIndirect Pressurized Glycol
External Heat Exchanger
![Page 47: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/47.jpg)
Pressurized GlycolBoiler with Indirect Water Heater
![Page 48: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/48.jpg)
Packaged Systems
![Page 49: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/49.jpg)
Packaged Systems
![Page 50: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/50.jpg)
Inside views
Heat Exchanger Module
Front View
![Page 51: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/51.jpg)
Heat Exchangers
•Internal•External•Thermosyphon•Single Wall•Double Wall
Leak Detection•Size - Heat transfer capability•Material- compatible to system & temperatures •Can it be disassembled to clean?
![Page 52: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/52.jpg)
![Page 53: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/53.jpg)
Counter Flow Through The Heat Exchanger
![Page 54: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/54.jpg)
Tube-in-Tube Rod
![Page 55: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/55.jpg)
Tube-in-Tube and Plate
![Page 56: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/56.jpg)
Tube-in Shell
![Page 57: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/57.jpg)
Double Wall Heat Exchanger and Air Separator
![Page 58: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/58.jpg)
THERMOSYPHONHEAT EXCHANGER
![Page 59: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/59.jpg)
Expansion Tank
Sized for the total expansion coefficient of the volume of fluid in the heat transfer loop at the highest operating temperature.
Larger vessels allow for more expansion at higher temperatures or stagnation of the system.
Water make-upPressure gauge
Back flow preventionWater meter
![Page 60: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/60.jpg)
Active Indirect Drain Back System
Hot
Cold
Circulator
Drain & Fill Valves
Drain back vessel is large enough to hold all the water in the loop.
![Page 61: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/61.jpg)
Active Indirect Drainback System
Water coil in the reservoir
Two pumps:
• Solar Pump
• Water Pump
![Page 62: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/62.jpg)
Reservoir with Sight Glass
![Page 63: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/63.jpg)
Reservoir With Dip Tube
![Page 64: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/64.jpg)
Reservoir with Heat Exchanger
![Page 65: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/65.jpg)
Indirect Drain Back System
Pump Options
1. High Head pump to provide lift and flow.
2. Two small circulatorsin Series to provide the required head.
After collectors fill, one shuts off to provide necessary circulation flow.
![Page 66: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/66.jpg)
Drain
Back Systems
Two Types:• Heat Exchanger on Storage Tank
• Heat Exchanger in Reservoir
Heat exchanger in the reservoir
Heat exchanger around the tank
![Page 67: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/67.jpg)
![Page 68: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/68.jpg)
![Page 69: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/69.jpg)
Drainback AdvantagesPositive Freeze Protection - Not dependent on electrical power or valve operationUses water
excellent thermal propertiesgood chemical stability, low cost
Thermal energy from collector is conserved in drainback tanks - not lost in exposed collectorsFluid stagnation not a problem in hot weather.Good for space heating.
![Page 70: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/70.jpg)
Drainback Disadvantages
Collectors have to withstand dry stagnationRequired elevation differences between collectors and drainback tanksHigher collector loop pump head (pressure) required.Piping must be carefully installed to provide positive drain.
![Page 71: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/71.jpg)
Combined
Hot Water and
Space Heating Systems
![Page 72: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/72.jpg)
Indirect Pressurized Glycol System
![Page 73: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/73.jpg)
Add a Heat Exchanger for the Heating Loop
![Page 74: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/74.jpg)
Solar Assisted AHU Fan Coil Heater
![Page 75: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/75.jpg)
2 Coil Storage with Boiler for Radiant Heating System
![Page 76: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/76.jpg)
Density and Gravity
Cold water has more density than hot water.
Cold water is heavier than hot water - gravity pulls the cold to the bottom of the storage tank - pushing hot water up to the top
![Page 77: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/77.jpg)
Passive System
ThermosyphonDirect - Vertical tank
![Page 78: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/78.jpg)
Thermosiphon
System
Passive SystemNo Pump Or Controller
Thermosiphon ActionDirect And Indirect SystemsSimple, Reliable SystemSimilar Valves Used
![Page 79: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/79.jpg)
Passive Indirect System
Thermosiphon systemInclude an antifreeze solution and a heat exchanger in the roof mounted tankRoof mounted tanks can also incorporate a heating element
![Page 80: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/80.jpg)
Indirect Thermosyphon
![Page 81: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/81.jpg)
Storage
Simplified graphic of a solar storage tank.
Collector feed
Collector return
Element&Thermostat
Hot out
ColdInlet
Anode rod
![Page 82: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/82.jpg)
Indirect Stone/Cement Lined Tank
![Page 83: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/83.jpg)
Wrap AroundOr
InternalHeat Exchanger
![Page 84: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/84.jpg)
Stainless Steel Tank
Internal Coil Heat Exchanger
![Page 85: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/85.jpg)
Duel Coil Solar Hot Water Storage Tank
![Page 86: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/86.jpg)
Heat Exchanger and
Solar Pump
![Page 87: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/87.jpg)
Water pump is considerably smaller than the solar pump.
Air separator in the solar loop
![Page 88: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/88.jpg)
VALVES
Necessity In Solar Water Heating SystemsExpel AirLimit Excessive Temperatures And PressuresPrevent Vacuum LocksIsolate System SectionsPrevent Thermosiphon Losses
![Page 89: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/89.jpg)
AIR VENT
Allows Air That Has Entered System To EscapeAir In System Would Restrict Fluid Flow
Located At The Highest Point Of The SystemMounted In Vertical PositionDust Cap On Valve Must Be Left Open Approx. 1/4 - 1/2 Turn
![Page 90: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/90.jpg)
Air Vent / Float Vent
Brass housing-high temp float
•Allows air out of system
•Prevents air lock
•Installed in highest point in plumbing system
![Page 91: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/91.jpg)
Air Vent with Ball Valve
Removes Air From System And Shut Off
![Page 92: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/92.jpg)
Pressure & Temperature Relief Valve
Protects System And Components From Excessive Pressures And TemperaturesStorage TankCollector Loop (Isolation)
Usually At Collector Outlet AreaP&T Valves Installed In Building Must Be Drained To Safe Location
![Page 93: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/93.jpg)
![Page 94: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/94.jpg)
Pressure Relief Valve
Protect From Excessive PressuresPressure Rating Less Than Pressure Ratings Of Other System Components Preferred Over Pressure-temperature Valves At The Collector
![Page 95: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/95.jpg)
Pressure Relief Valves
Protect components from excessive temperatures and/or pressuresLowest pressure rating in systemAre installed inside or outside the building and must drain to a safe location (the vent water is hot!)Pressure-only relief valve at collectorPressure & temperature relief needed at storage tank
![Page 96: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/96.jpg)
Pressure Relief Valve
No temperature probe
![Page 97: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/97.jpg)
Isolation Valves
Isolates Sections Of Solar SystemCollector Loop From TankCold Service
Ball ValveMost Efficient/Flow BarrierAlso Comes In Three-way Isolation/Drain
Gate ValveLess Effective Than Ball Separates Components Of The System For Maintenance Or Replacement
![Page 98: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/98.jpg)
Gate valves will fail
Ball valves are preferred
![Page 99: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/99.jpg)
Drain Valves
Used To Drain Collector Loop, Storage TankFill the System
![Page 100: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/100.jpg)
Check Valves
Critical In Solar System Prevents Loss Of Hot Tank Water At Night
ThermosiphoningCold Water Is Heavier Than WarmCold Pushes Hot WaterCold From Collector At Night Would Force Hot Water In Storage Tank Back Up To Collector
Freeze Prevention Valve
![Page 101: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/101.jpg)
Check Valves
Vertical Check ValvesMost CommonSpring CheckModified In Relation To Type Of System
Horizontal Check ValveMount In Horizontal Position
Motorized Check ValvePlumbed Near Storage Tank In Collector Loop Piping
![Page 102: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/102.jpg)
Spring & Swing Check Valves
![Page 103: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/103.jpg)
Anti-Scalding ValvesSafety Feature To Prevent Scalding Water From Reaching Fixtures
Solar water heating systems can create temperatures high enough to scald users.Adjustable between 105-140 degrees CMore accurate than mixing valve
![Page 104: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/104.jpg)
Tempering Valve
Mixes cold and hot waterDelivery temperature set by the user.
Used between the solar storage tank and the gas heater to prevent overheating burner control element
![Page 105: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/105.jpg)
CommercialMixing Valve
![Page 106: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/106.jpg)
Flow Balancing Valve
Set flow rate of each bank of collectors in a
commercial solar system
![Page 107: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/107.jpg)
Pulse Flow Meter
Determines Flow Rate For Calculating The Energy Production.
![Page 108: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/108.jpg)
UltrasonicFlow Meter
![Page 109: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/109.jpg)
BTU MeterCalculator
![Page 110: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/110.jpg)
Copper / Brass
Pipe and Fittings
![Page 111: System Types](https://reader034.fdocuments.us/reader034/viewer/2022050809/568bd5c11a28ab203499a0b7/html5/thumbnails/111.jpg)
End of Systems and Components