system that both provide comfortable environment and lower ...

12
BANPU Air Conditioner Control จิรายุ หาญวงษ 6130082121 ชตาทิพ มิตรเกื้อกูล 6130090121 ธนกฤต นามวงษ 6130208021 วริศรา กาญจนวีระโยธิน 6130484821 สรวิศ ตั้งถาวรสิริกุล 6131334521 Group 5.2 SEN_เล็กนํ้าใส

Transcript of system that both provide comfortable environment and lower ...

BANPU Air Conditioner Control

จิรายุ หาญวงษ 6130082121ชตาทิพ มิตรเกื้อกูล 6130090121ธนกฤต นามวงษ 6130208021วริศรา กาญจนวีระโยธิน 6130484821สรวิศ ตั้งถาวรสิริกุล 6131334521

Group 5.2 SEN_เล็กนํ้าใส

“ How do we create an air control system that both provide

comfortable environment and lower power usage?”

Use an IOT sensor to detect power usage. Use a set of questionnaires to estimate users satisfaction

Success indicating methods

Constraint

Controlled Area

Area of interest only include the reception room at the storeThe nature of air conditioners

We can only control 2 quantities through air conditioners, which are the temperature and air speed

Data of the Mean- radiant temperature cannot be retrieved

Unable to get a hold on to a black globe thermometer.

The location of air conditionersWe cannot change the location of air conditioners

The site is mostly off-limit

Due to Covid-19 circumstance, we can only go to the site to inspect once.

Fanger Comfort Eqaution

Heat loss from bodyMetabolism Heat storage of human body = -

● Evaporation loss● Respiratory heat loss● Heat loss from clothing

○ Radiation○ Convection○ Conduction(~0%)

Fanger Comfort Eqaution

● Air temperature● Mean radiant temperature● Air speed● Relative humidity

● Cloth index● Metabolic rate

Personal

Environmental

Predicted Mean Vote(PMV)

3

-1

1

-2

2

-3

Hot

Warm

Slightly warm

Neutral

Little cold

Chilly

Cold

0

Openstudio simulation

● Free program for heating ventilation and air conditioning calculation

● No need to install sensor● Simple way to calculate energy

consumption and thermal comfort

Self-calculation

● Need to install sensor to collect variables for calculation

● Self-calculated Fanger equation● Self-calculated energy

consumption

Concept Generation - Thermal Comfort and Energy Consumption Calculation

Concept Generation - Control system

Automatic System Special Remote Table and Manual Adjusting

● IOT system● Complicated● Simple for users

● Hand-operated● New device● Simple for users

● Hand-operated● Simple way to do

The longer you work on something, the better outcome you get. Given a limited period of time, is there a method that is timely appropriate?

Time

The best method can be very costly that we can not afford. Is there a method that gives us the best value for money?

Cost

Some method might work here but not there. Is there a method that is effective in this particular place?

Place

“We will construct a time machine”. Is our concept possible to do?

Feasibility

Concept Reduction

Fanger Thermal Comfort Calculation

Openstudio Simulation Self-calculationVS

Timely appropriated

Not effective with small space

Free

Very difficult to get right

Timely appropriated

Works well

Costly appropriated

High possibility

Air Controlling

Automatic system Special Remote Table and Manual Adjusting

Time consuming

Suits bigger space

Quite costly

Difficult yet possible

Time consuming

Suits bigger space

Bad value for money

Difficult yet possible

Timely appropraited

Good for tight space

Low cost

Easiest

collect datafrom sensors

Use data fit Heat transfer Eq.to find coefficient

Temperatureinside room

outside room

Relative humidity

inside room

Energyfrom

BANPU NEXTUse data and PMV value

Use data and Energy value

OptimisationPMV and energyvalueObtain Optimisation set for Temperature and humidity

Optimisation method

● Install sensor at B-Quick● Try optimisation algorithm● Plan other method if energy funcion does not fit

What’s Next?