System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document...

21
Buildsafe Scaffold Inspecon Handbook© All Rights Reserved - Document not current once printed 1 System Scaffold Inspecon Handbook Version 1.1

Transcript of System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document...

Page 1: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 1 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

System Scaffold Inspection HandbookVersion 1.1

Page 2: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 2 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

BUILDSAFECONTENTS

INSTALLATION CHECKLIST 4INSTALLATION CHECKLIST 5

SYSTEM SCAFFOLD - CONNECTION/STRUCTURE 6SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED 7SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED 8SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED 9SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED 10SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED 11

SYSTEM SCAFFOLD - PLATFORMS 12SYSTEM SCAFFOLD - PLATFORMS CONTINUED 13SYSTEM SCAFFOLD - PLATFORMS CONTINUED 14SYSTEM SCAFFOLD - PLATFORMS CONTINUED 15SYSTEM SCAFFOLD - PLATFORMS CONTINUED 16

SYSTEM SCAFFOLD - ACCESS AND EGRESS 17

SYSTEM SCAFFOLD - SIGNAGE 18

SYSTEM SCAFFOLD - SIGNAGE CONTINUED 19

SUMMARY 20

Page 3: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

Introduction

Buildsafe’s System Scaffold is a temporary working platform which provides protection for a person installing trusses, cladding, fascia, gutter, plasterboard as well as general construction work for both commercial or residential buildings. The Scaffold can also provide a safe means of access to different working heights.

Ladder access is provided within the system, allowing for easy access to and from the Work-ing Platform.

Page 4: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 4 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

INSTALLATION CHECKLIST

Use the Installation checklist provided below to conduct installation audits, make sure that you reference the content in the handbook for further information. If further information is required please contact Buildsafe. Questions which are not applicable put N/A in Yes field.

Page 5: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 5 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

INSTALLATION CHECKLIST

Page 6: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 6 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - CONNECTION/STRUCTURE

NO GO / EXCLUSION ZONESVICTORIADomestic/low voltage power lines – Less than 4.6mhorizontally and 5m verticallyIndustrial/high voltage power lines – Less than 8m all round

QUEENSLANDDomestic/low voltage power – Less than 3m all roundIndustrial/high voltage power lines – Less than 6m all round

NSWAny work within 4m of ALL power lines need referral to thenetwork operator for any special conditions which need to becomplied with.

If you are required to work within these distances ensure the client has sort advice from the power supply company (e.g. Energex - QLD) and has acted on advice given prior to beginning the installation/dismantle.

1. Has the system been erected within the electrical “No Go Zones/Exclusion Zones”?

2 x a

a = Depthof Trench

2. Is the Scaffold erected a safe distance away from trenches or excavations?

Scaffold must not be installed within a distance of 2 x the depth of a trench. Installing a Scaffold within this distance could cause the side of the trench to corrode and the Scaffold to collapse.

Page 7: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 7 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

Edge Protection by Scaffolding fitted with Platforms accessible from the struc-ture

(a)The minimum width of the Scaffold Platforms must not be less than 450mm.(b) The Scaffold Platform Edge must not be greater than 225mm horizontally distant

from the building Platform or Slab Edge.(c) The Scaffold Platform Edge must not be greater than 300mm vertically above or

below the building Platform or Slab Edge.

SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED

3. Is the scaffold platform at the correct height for its intended use?

4. Are the clearances between the Scaffold Platform and adjacent structure 225mm or less?

Platform

225mm maximum gap measured from floor edge

300mm maximum gap measured vertically from floor surface to Scaffold Platform up or down

Hop Up Platform

Scaffold

Page 8: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 8 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED

Check the following:• there should be a Sole Board where ever a Screw Jack does not land on concrete/solid

ground.• the Screw Jack needs to be placed in the centre of the Sole Board.• the Sole Boards needs to be on a flat and even surface.

5. Are all Jacks centered on Sole Boards?

Page 9: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 9 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

All Ledger and Transom pins need to be secured, the pins are secured and locked when the pin is wedged as shown below.

Unsecured Secured

6. Are Standards plumb throughout the installation?

7. Are Ledgers level throughout the installation?

All Standards need to be plumb throughout the entire Scaffold install. The Ledgers need to be level throughout the entire install.

SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED

Page 10: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 10 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED

When installing Decks to a height greater than 4m for the next Working Platform ensure that the Scaf-fold has been Braced correctly and the Scaffold has been Tied In, Buttress Bays or Outriggers have been installed. Do not allow a Scaffold to free stand more than 4m above the ground without Tying in, Buttress Bays or Outriggers being installed.

8. Are the Ties correctly positioned and correctly fixed?

9. If the Scaffold is to be utilised for “Fall Protection” extra support will be required such as Ties to the structure, Buttress Bays or Outriggers. Has this been done?

10. If the Bay width is 1200mm the max Platform height is 4000mm (2 Lifts) after this the Scaffold will require Ties to the structure, Buttress Bays or Outriggers. Has this been done?

Page 11: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 11 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - CONNECTION/STRUCTURE CONTINUED

11. If Scaffold runs onto roof, are 1200mm or 1500mm Sole Boards being utilised to span trusses?

When Scaffold runs onto roof 1200mm or 1500mm Sole Boards must be utilised to span the trusses allowing the wheight to be disrtibuted evenly into the main structure.

Page 12: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 12 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

No greater than 10mm

SYSTEM SCAFFOLD - PLATFORMS

Decks are supported by Ledger Transom, the feet hook over the Transom. The space be-tween individual decks must not be greater than 10mm.

Deck feet hookingover Transom

The Deck to the left is sitting in place correctly.

Ensure the gap between the Scaffold Decks is not greater than 10mm.

Page 13: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 13 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - PLATFORMS CONTINUED

Ensure Toeboards are installed the entire way around the Working Platform. ToeBoards must be installed to all Working Platforms that are over 2 meters.

12. If the Working Platform is above 2 meters have Toe Boards been installed?

Page 14: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 14 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - PLATFORMS CONTINUED

• Face and End Braces are installed no greater than 500mm apart in a zig zag formation starting in the bottom outside edge of the Scaffold continuing all the way up to the top Working Platform.

• Face Braces are only required on one end of the Scaffold because the Scaffold is only two Bays wide. Ensure the Face Braces are installed to the same Bay as the End Braces.

• Face Braces are required at each end of the Scaffold and on every fourth Bay.• End Braces are required on the end of the scaffold

Face Brace End Brace

13. Are the Face and End Braces evident?

Page 15: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 15 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - PLATFORMS CONTINUED

14. Are all Step Ups 500mm or less? If not, has a Stop End been installed to eliminate the fall hazard?

Platforms that are stepped greater than 500mm will require a Guardrail to be to installedor intermediated Steps installed.

Less than 500mm

Stop End

Page 16: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 16 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

• Outriggers or Ties are not required if the System Scaffold height does not exceed three times the least Base dimension.

• If System Scaffold height is greater than three times the least Base dimension, Outriggers, Ties or an extension of the least base width will be required.

• Ensure the tops of the Outriggers are attached to Standards greater than half the height of the working measured from the ground to the Working Platform height.

• Only two Outriggers can be used when the System Scaffold has been installed up next to a structure as shown in the illustration .

• In this situation both the Outriggers and the structure would prevent the System Scaffold from falling over.

SYSTEM SCAFFOLD - PLATFORMS CONTINUED

15. If the bay width is 700mm the max Platform height is 2000mm (1 Lift) after this the Scaf-fold will require Ties to the structure, Buttress Bays or Outriggers. Has this been done?

Page 17: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 17 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - ACCESS AND EGRESS

16. Is there a safe Access and Egress Point to the System Scaffold?

17. Is the Access Platform height less than 500mm maximum allowable step up?

18. If utilised, is the Access Ladder positioned at an angle between 70° - 80° (4:1 ratio)?

There must always be a safe Access and Egress Point to the System Scaffold. The Access and Egress Plat-form must not be greater than a hieght of 500mm maximum step up. All ladders utilised at the Access and Egress Points must be positioned at an angle between 70° - 80° (4:1 ratio).

Page 18: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 18 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - SIGNAGE

• The System Scaffold must have a Handover Certificate at the Scaffold Access Point. • Handover Certificate must be completed and fixed in a pouch next to the Access Point. • If the System Scaffold has been altered or re-installed a new Handover Certificate must

be issued.

19. Has the “Handover Certificate” been positioned at the access point on the Scaffold Sys-tem?20. Does the “Handover Certificate” outline the load capacity of the Scaffold System?

21. Is there a Scaffold build plan inside the Handover Pouch? (Qld only)

Page 19: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 19 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

SYSTEM SCAFFOLD - SIGNAGE CONTINUED

The System Scaffold install requires Signage to be considered compliant and also for marketing purposes. Buildsafe takes great pride in the products we offer which is why all installations must have a Buildsafe sign installed.

“We want the world to know who we are and what we do.”

Scaffold Incomplete Sign must be attached at the Access Point when Scaffolding is deemed incomplete and dangerous to use.

The Large Buildsafe Sign is to be attached to Ledgers or Transoms in the most visible location.

Page 20: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 20 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed

Use the following summary point as a guide when conducting the inspection:

• The “Handover Certificate” is been positioned at the Access Point on the Scaffold System.• The “Handover Certificate” outlines the load capacity of the Scaffold System.• There is a Scaffold Build Plan inside the Handover Pouch. (Qld only)• The Scaffold System has not been erected within the electrical “No Go Zones/Exclusion

Zones”?• The scaffold is erected a safe distance away from trenches or excavations.• All Jacks are centered on Sole Boards.• Standards are plumb throughout the installation.• Ledgers are level throughout the installation.• The Face Braces are evident.• If the bay width is 1200mm the max platform height is 4000mm (2 Lifts) after this the

Scaffold will require ties to the structure, Buttress Bays or Outriggers. Has this been done.• If the Bay width is 700mm the max Platform height is 2000mm (1 Lift) after this the

Scaffold will require Ties to the structure, Buttress Bays or Outriggers. Has this been done.

• If the Scaffold is to be utilised for “Fall Protection” extra support will be required such as Ties to the structure, Buttress Bays or Outriggers. Has this been done?

• The Ties are correctly positioned and correctly fixed.• If Scaffold runs onto roof, are 1200mm or 1500mm Sole Boards being utilised to span

trusses?• The Scaffold Platform is at the correct height for its intended use.• The clearances between the Scaffold Platform and adjacent structure is 225mm or less.• All Step Ups are 500mm or less? If not, has a Stop End been installed to eliminate the fall

hazard?• The Working Platform that are above 2 meters have Toe Boards installed.• There is a safe Access and Egress Point to the System Scaffold.• The Access Platform height is less than 500mm maximum allowable step up.

SUMMARY

Page 21: System Scaffold - Buildsafe · Buildsafe Scaffold Inspection Handbook All ights eserved - Document not current once printed 3 Buildsafe Scaffold Inspection Handbook All ights eserved

Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed 21 Buildsafe Scaffold Inspection Handbook© All Rights Reserved - Document not current once printed www.buildsafe.net.au