System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x...

34
1 (June / 2000) Notes ----------------------------------------------------------------------P2 teamserver HS900 -----------------------------------------------------P10 PRIMERGY MS610---------------------------------------------------P12 PRIMERGY MS380---------------------------------------------------P16 PRIMERGY ES280----------------------------------------------------P18 PRIMERGY ES210----------------------------------------------------P20 PRIMERGY ES200----------------------------------------------------P22 External Disk Array ---------------------------------------------------P23 External Devices -------------------------------------------------------P24 Rackmount -------------------------------------------------------------P25 Hardware----------------------------------------------------------------P27 System Configuration Guide ( V.2 ) CPU slot RAM module slot 3.5 inch HDD Bay 5 inch Bay RS-232C PCI slot ISA slot Redundant PSU Others Index The numbers on the left hand side of each page correspond to the various options available with teamservers as follows : Key to Or And

Transcript of System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x...

Page 1: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

1

(June / 2000)

Notes ----------------------------------------------------------------------P2teamserver HS900 -----------------------------------------------------P10PRIMERGY MS610---------------------------------------------------P12PRIMERGY MS380---------------------------------------------------P16PRIMERGY ES280----------------------------------------------------P18PRIMERGY ES210----------------------------------------------------P20PRIMERGY ES200----------------------------------------------------P22External Disk Array ---------------------------------------------------P23External Devices -------------------------------------------------------P24Rackmount -------------------------------------------------------------P25Hardware----------------------------------------------------------------P27

System Configuration Guide (V.2)

CPU slotRAM module slot3.5 inch HDD Bay5 inch BayRS-232CPCI slotISA slotRedundant PSUOthers

Index

The numbers on the left hand side of each page correspond to the various options available with teamservers as follows :

Key to

Or And

Page 2: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

2

NOTES

Disk array configuration

● Physical pack ● ● ● Physical pack. A collection of physical HDDs comprising a RAID. ● Logical drive ● ● ● Logical drive. The logical drive (eg. D: ) as seen by the Operating System.● Partition ● ● ● Partition. One of the logical access units into which a logical drive is divided.

Physical pack

Logical drive A

Logical drive B * Drives can be divided into partitions.

Logical drive C

<Restrictions>

(1) Each physical pack must contain the same type(size) of HDDs. (2) Maximum logical drive size is 2TB (GP5U141 / U142 / -143 / -144 / -146).(3) The number of HDDs comprising a physical pack is as shown below.

RAID Level Description HDDs Capacity of logical drives

RAID 0 The data is broken down into blocks, 2~8 The capacity of logical drive is sameeach on a separate disk drive as the capacity of connected HDD.

RAID 1 Duplicates the disk and writes 2 The capacity of the logical drive isthe same data onto two disks. half the capacity of connected HDD.

RAID 5 The data is broken down into blocks 3~8 The capacity of each logical drive isand each blocks is written together the number of connected HDDs - 1). with parity bits on a separate disk drive.

RAID 6 Duplicates the disk and broken down 3~8 The capacity of each logical driveinto blocks, each on a is the half the capacity of connectedon a separate disk. (RAID0+1) HDD. (GP5-143 / 144 / 146)

* GP5U141 / 142: RAID6 is available with Firmware 4.04-F-56 or greater

(4) The same RAID level must be use when dividing a physical pack into a number of logical drives.(5) A physical pack must contain only HDDs which are connected by the same RAID card.(6) A RAID card can support more than one physical pack. ( even if different RAID levels)(7) Same capacity HDDs connected to the same RAID Card, must also have the same r.p.m speed.

RAID

This must be 9GBwith 7200rpm HDD!9GB

7200rpm

9GB7200rpm

9GB10000rpm

Partition 1Partition 2

HDD HDD HDD HDD

Page 3: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

3

NOTES

Hard disk cabinet / RAID card / SCSI card

● GP5MS623A/GP5UR1DC5:

Note: The operating System must be installed on an internal hard disk.

● RAID card (GP5U141 / GP5-144 / GP5-146)1.Up to two Hard disk cabinets can be connected to one RAID card.

(Up to three can be connected with one GP5-144 card)2.When using GP5U141 in ES280/MS380, it cannot be used for both

external disk array (GP5UR1DC5 / GP5MS623A) and internal disk array. 3.Internal and external array devices cannot be connected to the same channel.4.GP5-144 / 146 can only be used with GP5-144 / 146, they cannot be mixed with GP5U141 / 142 / -143)5.Up to two 146 can be used for internal array configuration in MS3806.When installing three RAID cards in MS380, the internal HDD must be connected using GP5-144

● RAID card (GP5U142 / GP5-143)Only for use with internal devices.Only one of these RAID cards can be used per server.

● SCSI card (GP5-125 / GP5-126 / GP5-127)1.Internal and external devices cannot be connected to the same SCSI card.2.Only one Hard disk cabinet can be connected. (Daisy chain connection is not available)

Number of connectable Hard Disk Cabinets

Product ES200 ES210 ES280 MS380 MS610 HS900Hard Disk Node

Hard Disk Cabinet GP5MS623A 2 2 4 4 4 -

Storage System GP5UR1DC5 - - 4 4 4 12

Mounting internal devices in HS900

In HS900, there are two internal HDD bays (9GB / 18GB / 36GB disks are available)Storage System (GP5UR1DC5) is required for data storage.Boot disk can be an external disk.HS900 has no internal 5" bay in chasis, so Backup cabinet (GP5UR1BC1) is required to mount backup devices.

Mounting internal device (HDD / Backup device) in MS610

The following figure indicates the right adapters (Onboard SCSI channel, SCSI Card, etc.) used to mount devicesin MS610

● Drive Cage Conversion Kit (GP5BBU1) Applicable products ● ● ● MS610

- Standard Drive CageSCSI Channel ● ● ● 1ch

Number of mountable HDD ● ● ● 1inch height Hard Disk Drive x 8 (8HDDs per 1ch)

- Drive Cage Conversion Kit (GP5BBU1)SCSI Channel ● ● ● 2ch

Number of mountable HDD ● ● ● 1inch height Hard Disk Drive x 12 (6HDDs per 1ch x 2)

Page 4: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

4

NOTES

The following figure indicates the correct adapters (Onboard SCSI channel, SCSI Card, etc.) to use to mount devices in MS610

PRIMERGY MS610Connection of internal HDD and internal backup devices

Internal HDD Internal backup device

Connection Pattern One device is connected Two devices are connected

Configuration Drive Cage SCSI Host Cable Internal HDD Narrow Wide Narrow Wide Narrow device

Interface connect connect device x 2 device x 2 and

device*2 device*3 Wide device

Cable(X1) 1) 9GB, 7,200rpm

Standard Ultra 160 Onboard SCSI (Standard 2) 18GB, 7,200rpm

(8Bays) (Ultra160 A) equipment) 3) 9GB, 10,000rpm

4) 18GB, 10,000rpm

5) 36GB, 10,000rpm Wide-1 Onboard Narrow:

SCSI When Drive Cable(X2) 1) 9GB, 7,200rpm Onboard Onboard Narrow-1,2 SCSI(Wide) Onboard SCSI (Narrow)

Configuration Cage Ultra 160 Onboard SCSI (Standard 2) 18GB, 7,200rpm SCSI SCSI(Wide ) Onboard

Conversion (Ultra160 A/B) equipment) 3) 9GB, 10,000rpm (Narrow) SCSI (Narrow) Wide-2 SCSI Card Wide:

4) 18GB, 10,000rpm Daisy chain (GP5-127) SCSI Card (GP5-127)

(12Bays)*1 5) 36GB, 10,000rpm

Cable(X1) 1) 9GB, 7,200rpm

Standard Ultra2 Wide RAID Card (Standard 2) 18GB, 7,200rpm

(8Bays) GP5-144/146 equipment) 3) 9GB, 10,000rpm

(Ch0) 4) 18GB, 10,000rpm

Array 5) 36GB, 10,000rpm

Configuration When Drive RAID Card Cable(X2) 1) 9GB, 7,200rpm

Cage Ultra2 Wide GP5-144/146 (Standard 2) 18GB, 7,200rpm

Conversion (Ch0/1) equipment) 3) 9GB, 10,000rpm

4) 18GB, 10,000rpm

(12Bays)*1 5) 36GB, 10,000rpm

*1 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501

*2 Wide connect devices: GP5-DT401/GP5-ML301/GP5-DL351(SCSI Cable is standard equipment with all Wide connect devices)

*3 Daisy chain is not available for connection of a Wide SCSI connection device to Onboard SCSI (Wide)

MS380 has eight HDD bays and 18.2GB/9GB HDD (1"height) can be mounted. Up to six HDDs with 10000rpm (GP5-HDH9A/GP5-HDH87) can be mounted.(10000rpm HDD cannot be used with 7200rpm HDD)SCSI Card (GP5-127) is required if DLT unit (GP5-DL351), DAT unit (GP5-DT401) or Tape unit (GP5-ML301) is installedOnly one DDS-4 (GP5-DT401) can be mounted in the lowest 5inch bay.

PRIMERGY MS380Connection of internal HDD and internal backup devices

Internal HDD Internal backup device (Max.2)

Connection Pattern One device is connected Two devices are connected

Connection SCSI Host Cable Internal HDD Narrow Wide Narrow device Wide device Narrow device and

Interface connect connect x 2 x 2 Wide device

device*1 device*2

1)9GB,7,200rpm

Cable(X1) 2)18GB,7,200rpm Wide-1 Narrow device:

Ultra2 Wide Onboard SCSI (Standard 3)9GB,10,000rpm Narrow-1,2 SCSI Card Onboard

SCSI Configuration equipment) 4)18GB,10,000rpm Onboard SCSI Card (GP5-127) SCSI(Narrow)

SCSI(Narrow) (GP5-127) Onboard

connection SCSI(Narrow) Wide-2 Wide device:

RAID Card Cable(X1) 1)9GB,7,200rpm Daisy chain SCSI Card SCSI Card(GP5-127)

Array Configuration Ultra2 Wide GP5U142/-144/-146(Standard 2)18GB,7,200rpm connection (GP5-127)*3

(Ch0) equipment) 3)9GB,10,000rpm

4)18GB,10,000rpm

*1 Narrow connect devices: GP5UDL201/GP5UDT301/GP5USL501

*2 Wide connect devices: GP5-DT401/GP5-ML301/GP5-DL351(SCSI Cable is standard equipment with all Wide connect devices)

*3 Daisy chain is not available for connection of a Wide SCSI connection device to SCSI Card (GP5-127)

Narrow

Wide A

Wide B

OnboardSCSI

For backup device (Narrow)

For HDD

For HDD

Narrow

Ultra160 A

Ultra160 B

OnboardSCSI

For backup device (Wide)

For HDD

For HDD

Mounting internal SCSI devices (HDD/Backup device) in MS380

Wide

For backup device (Narrow)

Select either of the SCSI channel

Page 5: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

5

NOTES

ES280 have four HDD bays (3hotplug and 1non hotplug) 9GB/18.2GB HDD (1"height) can be mounted. SCSI Card (GP5-125) is required if DAT unit (GP5-DT401), Tape unit (GP5-ML301) is installed

PRIMERGY ES280Connection of internal HDD and internal backup devices

Internal HDD Internal backup device (Max:2)

Connection Pattern One device is connected Two devices are connected

Connection Interface Narrow connect Wide connect Narrow device and

Host Internal HDD device *1 device *2 Narrow device x 2 Wide device x 2 Wide device

SCSI Ultra Wide Onboard SCSI (Wide) 1)9GB,7,200rpm Narrow device:

Configuration SCSI SCSI Cable (GP5-843) 2)18GB,7,200rpm Onboard SCSI Onboard SCSI

(Narrow) SCSI Card (Narrow)

Onboard SCSI (Narrow) SCSI Card SCSI Cable (Std.) (GP5-125 *3) SCSI Cable(Std.)

SCSI Cable (Std.) (GP5-125 *3) Daisy chain

with primary (SCSI Card is Wide device:

Array Ultra2 Wide RAID Card 1)9GB,7,200rpm connected device required per device) SCSI Card

Configuration SCSI (GP5-143) 2)18GB,7,200rpm (GP5-125)

SCSI Cable(GP5-843)

*1 Narrow connect devices: GP5UDT301/GP5USL501

*2 Wide connect devices: GP5-DT401/GP5-ML301(SCSI Cable is standard equipment with all Wide connect devices)

*3 Daisy chain is not available for connection of a Wide SCSI device to SCSI Card(GP5-127)

ES210/200 have four HDD bays (three HDD bays and one 5inch bay) 9GB/18.2GB HDD (1"height) can be mounted.

ES210: HDD can be connected to Onboard UltraWide SCSI. (SCSI Cable is required)SCSI Card (GP5-127) is required for Ultra2 Wide configuration. SCSI Card (GP5-127) is required to mount DDS4 backup device.

ES200: SCSI Card (GP5-126) is required to mount HDD. The SCSI Card (GP5-126) is also used for connection to Narrow connect backup device (GP5UDT301/GP5USL501) with SCSI Cable (.GP5-841)SCSI Card (GP5-127) is required to mount Wide connect backup device (GP5-DT401/GP5-ML301).

There are two SCSI channels and two EIDE channels on the Motherboard

PRIMERGY ES210Connection of internal HDD and internal backup devices

Internal HDD Internal backup device (Max:2)

Connection Pattern One device is connected Two devices are connected

Connection Interface Narrow connect Wide connect Narrow device and

Host Internal HDD device *1 device *2 Narrow device x 2 Wide device x 2 Wide device

SCSI Ultra Wide Onboard SCSI (Wide) 1)9GB,7,200rpm Narrow device:

Configuration SCSI SCSI Cable (GP5-843) 2)18GB,7,200rpm Onboard SCSI Onboard SCSI

SCSI Ultra2 Wide SCSI Card(GP5-127) 1)9GB,7,200rpm (Narrow) SCSI Card (Narrow)

Configuration SCSI SCSI Cable(GP5-843) 2)18GB,7,200rpm Onboard SCSI (Narrow) SCSI Card SCSI Cable (Std.) (GP5-127 *3) SCSI Cable(Std.)

IDE IDE Onboard Primary IDE 1)20.4GB, 5400rpm SCSI Cable (Std.) (GP5-127 *3) Daisy chain

Configuration UltraDMA/33 with primary (SCSI Card is Wide device:

Array Ultra2 Wide RAID Card 1)9GB,7,200rpm connected device required per device) SCSI Card

Configuration SCSI (GP5-143) 2)18GB,7,200rpm (GP5-127)

SCSI Cable(GP5-843)

*1 Narrow connect devices: GP5UDT301

*2 Wide connect devices: GP5-DT401(SCSI Cable is standard equipment with all Wide connect devices)

*3 Daisy chain is not available for connection of a Wide SCSI device to SCSI Card(GP5-127)

Mounting internal SCSI devices (HDD/Backup device) in ES280

Narrow

Wide B

OnboardSCSI

For backup device (Narrow)

For HDD

Secondary EIDE

Primary

Narrow

OnboardIDE Controler

For CD-ROM

For HDD

For backup devide (Narrow)

For HDDWide

OnboardSCSI Controler

Mounting internal SCSI devices (HDD/Backup device) in ES210/ES200

Page 6: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

6

NOTES

There are two EIDE channels on Motherboard

PRIMERGY ES200Connection of internal HDD and internal backup devices

Internal HDD Internal backup device (Max:2)

Connection Pattern One device is connected Two devices are connected

Internal HDD Interface Narrow connect Wide connect Narrow device and

Host Internal HDD device *1 device *2 Narrow device x 2 Wide device x 2 Wide device

SCSI Card(GP5-126) SCSI Card(GP5-126) Narrow device:

SCSI Ultra2 Wide SCSI Card(GP5-126) 1)9GB,7,200rpm SCSI Cable(GP5-841) SCSI Card SCSI Cable(GP5-841) SCSI Card SCSI Card(GP5-126)

Configuration SCSI SCSI Cable(GP5-843) 2)18GB,7,200rpm (SCSI Card can be used (GP5-127 *3) Daisy chain with primary (GP5-127 *3) SCSI Cable(GP5-841)

for both HDD and backup connected device connection (SCSI Card can be used

backup device) (SCSI Card is required per for both HDD and backup

IDE IDE Onboard Primary IDE 1)20.4GB, 5400rpm SCSI Card(GP5-127 ) SCSI Card(GP5-127) device) device)

Configuration UltraDMA/33 SCSI Cable(GP5-840) SCSI Cable(GP5-841) Wide device:

Daisy chain with primary SCSI Card

Array Ultra2 Wide RAID Card 1)9GB,7,200rpm connected device (GP5-127 *3)connection

Configuration SCSI (GP5-143) 2)18GB,7,200rpm (SCSI Card is required per

SCSI Cable(GP5-843) device)

*1 Narrow connect devices: GP5UDT301/GP5USL501

*2 Wide connect devices: GP5-DT401/GP5-ML301(SCSI Cable is standard equipment with all Wide connect devices)

*3 Daisy chain is not available for connection of a Wide SCSI device to SCSI Card(GP5-127)

Main unit Product Succesor HDD Interface Height Revolution RemarksProduct ID

ES200 Hard disk drive-9GB GP5-HD9G3 Ultra2Wide 1" 7200rpmGP5-HD9G3C Ultra2Wide 1" 7200rpm For mounting in 5" bay

Hard disk drive-18GB GP5-HD8G1 Ultra2Wide 1" 7200rpmGP5-HD8G1C Ultra2Wide 1" 7200rpm For mounting in 5" bay

Hard disk drive-20GB GP5-HD2E1 UltraDMA/33 1" 5400rpm IDE HDDES210 Hard disk drive-9GB GP5-HD9G3 Ultra2Wide 1" 7200rpm

GP5-HD9G3C Ultra2Wide 1" 7200rpm For mounting in 5" bayHard disk drive-18GB GP5-HD8G1 Ultra2Wide 1" 7200rpm

GP5-HD8G1C Ultra2Wide 1" 7200rpm For mounting in 5" bayHard disk drive-20GB GP5-HD2E1 UltraDMA/33 1" 5400rpm IDE HDD

ES280 Hard disk drive-9GB GP5-HD9G3 Ultra Wide 1" 7200rpm Non hotplugHard disk drive-9GB GP5-HDH96 Ultra Wide 1" 7200rpmHard disk drive-18GB GP5-HD8G1 Ultra Wide 1" 7200rpm Non hotplugHard disk drive-18GB GP5-HDH83 Ultra Wide 1" 7200rpm

MS380 Hard disk drive-9GB GP5-HDH96 Ultra2Wide 1" 7200rpmHard disk drive-18GB GP5-HDH83 Ultra2Wide 1" 7200rpmHard disk drive-9GB GP5-HDH9A Ultra2Wide 1" 10000rpm Up to six can be mountedHard disk drive-18GB GP5-HDH87 Ultra2Wide 1" 10000rpm Up to six can be mounted

MS610 Hard disk drive-9GB GP5-HDH9B Ultra160 1" 7200rpm Available as of August 20thHard disk drive-9GB GP5-HDH9A Ultra 160 1" 10000rpmHard disk drive-18GB GP5-HDH88 Ultra160 1" 7200rpm Available as of August 20thHard disk drive-18GB GP5-HDH87 Ultra 160 1" 10000rpmHard disk drive-36GB GP5-HDH63 Ultra 160 1" 10000rpm Available as of August 20th

HS900 Hard disk drive-9GB GP5-HDH98T Ultra2Wide 1" 10000rpmHard disk drive-18GB GP5-HDH85T Ultra2Wide 1" 10000rpmHard disk drive-36GB GP5-HDH61T Ultra2Wide 1.6" 10000rpm

* GP5-HDH62 is continued for additional or spair HDD in MS600 and Storage System (GP5UR1DC4)

S.M.A.R.T. function is available in the combinations shown below:■ :Corresponds , x:Does not correspond , -:N/A

Internal Hard disk units Hard disk cabinetStandard SCSI Hard disks GP5UR1DC5/GP5MS623A

Models equipment SCSI card RAID card SCSI card RAID cardIDE SCSI GP5-126 GP5-127 GP5U141 GP5-143 GP5-144 GP5-146 GP5-125 GP5-127 GP5U141 GP5-144 GP5-146

ES200 ■ - ■ - - ■ - ■ - ■ - - ■ES210 ■ ■ - ■ - ■ - ■ - ■ - - ■ES280 - ■ - - x ■ - - ■ - x - -MS380 - ■ - - - - ■ ■ - ■ - ■ ■MS610 - ■ - - - - ■ ■ - ■ - ■ ■HS900 - ■ - - - - ■ ■ - ■ - ■ ■Caution: Intel LANDesk Server Manager or Fujitsu Servervisor is required for SMART function

S.M.A.R.T function

Mountable Hard Disk Drives for each model

Secondary EIDE

Primary

OnboardIDE Controler

For CD-ROM

For HDD

Page 7: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

7

NOTES

(HS900)A memory board with 16slots is standard equipment and up to 16GB memory can be mounted. When you add more than 16GB, an additional Memory Board (GP5-RB201) is required.When using two memory boards in HS900, the same memory size must be mounted on each board.

(MS610)Mount the same capacity DIMM's in units of four.(Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (A1 to A4) to bank D (D1 to D4)

Caution

Address area of 3.5GB ~4.0GB is assigned for PCI resource, cannot be used.

(MS380/ES280/ES210/ES200)The mother board has four slots for RAM modules (including base memory), install RAM modules in slot number order.(ES200 has three slots)

Configuration To Order (CTO) is available with PRIMERGY MS610/MS380/ES280/ES210/ES200.Products are delivered with options (HDD, Memory, Backup device, etc.) already mounted as per customer requirements.

1. How shipped

2. Applicable products for CTO

(1)Main unitMS610 / MS380 / ES280 / ES210 / ES200Storage System (GP5UR1DC5)/Hard Disk Cabinet (GP5MS623A)

(2) Option (GP5BXXX)All options which are connectable with the servers above.

CPU Field Upgrade Kit GP5BFG20H / GP5BFG20GGP5BFG20C / GP5BFG20B / GP5BFG205 / GP5BFG12Y

Additional Memory GP5BRM4N / GP5BRM2N / GP5BRM1N / GP5BRM51N /GP5BRM25NGP5BRM51F / GP5BRM25F / GP5BRM12F / GP5BRM64FGP5BRM25H / GP5BRM12H / GP5BRM64H

Standard Memory Conversion Kit GP5BRU4GA / GP5BRU2GC / GP5BRU1GF / GP5BRU51KGP5BRU25E / GP5BRU51F / GP5BRU25D

Hard Disk Drive GP5BHDH63 / GP5BHDH87 / GP5BHDH9A / GP5BHDH84 / GP5BHDH97 / GP5BHD8G1 / GP5BHD9G3 / GP5BHD8G1C / GP5BHD9G3C / GP5BHD2E1

Drive Cage Conversion Kit GP5BBU1Backup Device GP5BDT401 / GP5BDT301 / GP5BSL501 / GP5BDL201 / GP5BDL351 / GP5BML301Redundant PSU GP5BUPU131 / GP5BUPU151 / GP5BUPU161 / GP5BUR1PU1SCSI Card / RAID Card GP5B125 / GP5B126 / GP5B127 / GP5B128 / GP5BU141 / GP5B143 / GP5B144 / GP5B146SCSI Cable GP5B831 / GP5B840 / GP5B841 / GP5B842 / GP5B843LAN Card GP5B183 / GP5B185 / GP5B186 / GP5B187Others GP5BUSM103

Mounting additional memory

Configuration To Order

[CTO option]

(1) CPU+Chassis+Memory+ Shipment

[Main unit]

(2) Mount option in free slots

(3) Standard Memory / Drive Cage conversion

Standard Memory

128MB

128MB

128MB

128MB

256MB

256MB

512MB

512MB#1 #2 #3

#5 #6 #7 #8 #9 #10 #11 #12

#13 #14 #15 #16

128MB

128MB

128MB

128MB

256MB

256MB

512MB

512MB#1 #2 #3

#5 #6 #7 #8 #9 #10 #11 #12

#13 #14 #15 #16

Additional Memory Board (GP5-RB201)

Memory BoardD1B1C1A1D3B3C3A3

D2B2C2A2D4B4C4A4

Page 8: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

8

NOTES

HS900 MS610Maximum Maximum

number number

Cards Product ID Bus of cards Total REMARKS Cards Product ID Bus of cards Total REMARKS

mounted mounted

SCSI card GP5-123 PCI32 2 8 10 For external disk array SCSI card GP5-123 PCI64 2 For external disk array

(Ultra Wide Diff) (Ultra Wide Diff) 4 8

SCSI card GP5-127 PCI32 6 SCSI card GP5-127 PCI64 3 3

(Ultra2 Wide LVD) (Ultra2 Wide LVD)

RAID card GP5-144 PCI64 8 RAID card GP5-144 PCI64 3

(Ultra2 Wide LVD) (Ultra2 Wide LVD)

RAID card GP5-146 PCI64 8 RAID card GP5-146 PCI64 2

(Ultra2 Wide LVD) (Ultra2 Wide LVD)

LAN card GP5-183 PCI64 1 4 Giga LAN LAN card GP5-183 PCI64 1 3 Giga LAN

(1000Base-SX) (1000Base-SX)

LAN card GP5-185 PCI32 3 LAN card GP5-185 PCI32 3

(100Base-TX) (100Base-TX)

LAN card GP5-187 PCI32 3 IPsec LAN LAN card GP5-186 PCI32 1 Dual Port LAN

(100Base-TX) (100Base-TX)

LAN card Standard PCI32 1 LAN card GP5-187 PCI32 3 IPsec LAN

(100Base-TX) equipment (100Base-TX)

Server Monitor Module GP5USM103 PCI32 1 1 Server Monitor Module GP5USM103 PCI32 1 1

MS380 ES280Maximum Maximum

number number

Cards Product ID Bus of cards Total REMARKS Cards Product ID Bus of cards Total REMARKS

mounted mounted

SCSI card GP5-123 PCI32 2 3 5 External disk array SCSI card GP5-125 PCI32 3 3 3 Only for external

(Ultra Wide Diff) (Ultra Wide) SCSI devices

SCSI card GP5-127 PCI32 3 External HDD RAID card GP5U141 PCI32 2 Internal/External

(Ultra2 Wide LVD) (Ultra Wide) 2 array configuration

RAID card GP5-144 PCI64 3 Internal/External array RAID card GP5-143 PCI32 1 Only for internal array

(Ultra2 Wide LVD) configuration Cannot be (Ultra Wide) configuration

used with GP5U141/142 LAN card GP5-183 PCI32 1 3 Giga LAN

RAID card GP5-146 PCI64 2 Internal/External array (1000Base-SX)

(Ultra2 Wide LVD) configuration Cannot be LAN card GP5-185 PCI32 3

used with GP5U141/142 (100Base-TX)

LAN card GP5-183 PCI64 1 3 Giga LAN LAN card GP5-187 PCI32 3 IP sec LAN

(1000Base-SX) (100Base-TX)

LAN card GP5-185 PCI32 3 Server Monitor Module GP5USM103 PCI32 1 1

(100Base-TX)

LAN card GP5-187 PCI32 3

(100Base-TX)

Server Monitor Module GP5USM103 PCI32 1 1

ES210 ES200Maximum Maximum

number number

Cards Product ID Bus of cards Total REMARKS Cards Product ID Bus of cards Total REMARKS

mounted mounted

SCSI card GP5-127 PCI32 3 Internal HDD/Backup device SCSI card GP5-126 PCI32 1 3 Internal HDD/Backup

(Ultra 2Wide LVD) /External device (Ultra 2Wide LVD) 3 device/External device

RAID card GP5-143 PCI32 1 3 Internal array configuration SCSI card GP5-127 PCI32 3 Internal Backup device

(Ultra2 Wide LVD) 2 (Ultra 2Wide LVD) /External device

RAID card GP5-146 PCI64 1 External array configuration RAID card GP5-143 PCI32 1 Internal array

(Ultra2 Wide LVD) (Ultra2 Wide LVD) 2 configuration

LAN card GP5-183 PCI64 1 3 Giga LAN RAID card GP5-146 PCI64 1 4 External array

(1000Base-SX) 3 (Ultra2 Wide LVD) configuration

LAN card GP5-185 PCI32 3 LAN card GP5-183 PCI64 1 3 Giga LAN

(100Base-TX) (1000Base-SX)

LAN card GP5-187 PCI32 3 IPsec LAN LAN card GP5-185 PCI32 3

(100Base-TX) (100Base-TX)

Server Monitor Module GP5USM103 PCI32 1 1 LAN card GP5-187 PCI32 3 IPsec LAN

(100Base-TX)

Server Monitor Module GP5USM103 PCI32 1 1

Server monitoring software (Servervisor V1.0 and Intel LANDesk Server Manager V6.0) is bundled with all teamservers

Mountable Card options

Page 9: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

9

NOTES

Differences in function between Servervisor and Intel LANDesk Server Manager are indicated below:

Items Servervisor V1.0 Intel LANDesk Server Manager V6.0

Product ES200/ES210/ES280/MS380 All products

MS610/HS900

Main function Server status monitoring Server status monitoring

Error notification Error message

Remote control

WindowsNT performance monitoring

(e.g. CPU/Memory utilization)

Alert function Internet mail transmission Internet mail transmission

SNMP Trap transmission SNMP Trap transmission

Message box Message box (*On the monitored server)

(*On the monitored server) Pager

Activation by program

Broadcast to connected clients

SMM support No Yes

Required memory capacity 6~10MB 32~64MB

Advantage Servervisor provides the minimum functions LDSM is suitable for systems employing

required for server management to reduce remote central monitoring or

the amount of resources used, SMM based monitoring to provide

making it convenient for a small-scale system a more powerful server management function.

without a dedicated manager. - Powerful functions

- Simplified operation, light-weight

- Easy to use

*1 Remote monitoring is provided by System Walker plus LiveHelp. Remote control and WindowsNT performance

monitor are provided by System Walker.

*2 If the message box is to be displayed for server error detection, the message box must be logged on to the server.

Errors that occur while the message box is not logged on can be reported using Internet mail and SNMP Trap.

The event log also can be used to check whether such errors have occurred.

Differentiation between Servervisor and Intel LANDesk Server Manager

Page 10: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

10

NOTES

teamserver HS900

CPU: Pentium(R) lllXeon (550MHz) x 2(~8) , Cache (L1+L2) : 32KB+2MB/1MB, Internal Hard disk bay:(Hot-plug) 2bays,

2 x Ultra2 Wide SCSI Onboard, 2ch RAID Card, CD-ROM, LAN Card (Std.), Redundant Power Supply (Std.)/FAN (Std.),

Intel LANDesk Server Manager/Servervisor, ServerWizard

GP5T9A32R Rackmount Type 2 x Pentium(R) lll Xeon 550MHz(2MB), Memory:1GB(ECC), HDD:Option

Rackmount Type GP5T9A22R Rackmount Type 2 x Pentium(R) lll Xeon 550MHz(1MB), Memory:1GB(ECC), HDD:Option

Standard : 2CPUs Max : 8CPUs

1 CPU Field Upgrade Kit (Pentium III Xeon -550MHz (2MB) x1)

GP5-FG203T

CPU Field Upgrade Kit (Pentium III Xeon-550MHz (1MB) x1)

GP5-FG202T

Max. memory: 32GB

2 Additional Memory - 256MB (128MB-DIMMx2)

Standard memory : 1GB (128MB-DIMMx8) GP5-RM25J

2 Additiond Memory Board Additional Memory - 512MB (256MB-DIMMx2)

GP5-RB201 GP5-RM51J

Additional Memory - 1GB (512MB-DIMMx2)

GP5-RM1J

Up to two HDDs can be mounted in the main unit Additional Memory - 2GB (1GB-DIMMx2)

GP5-RM2J

SCSI on board Max : 2 Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)

3 (Hot Plug)

GP5-HDH98T

6

RAID Card (GP5-146 : std.) Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)

(Hot Plug)

GP5-HDH85T

Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)

(Hot Plug)

GP5-HDH61T

Max : 8 Hard Disk Drive - 36GB (Ultra160.10,000rpm)

6 (Hot Plug GP5-HDH63/GP5BHDH63

Available as of August 20th

SCSI Card (Ultra2 Wide) SCSI Cable(3m) Max : 1

GP5-127 GP5MU823A Storage System Hard Disk Drive - 9GB (Ultra160.10,000rpm)

GP5UR1DC5 (Hot Plug GP5-HDH9A/GP5BHDH9A

SCSI Cable(5m) Hard Disk Drive - 18GB (Ultra160.10,000rpm)

GP5S-833 (Hot Plug GP5-HDH87/GP5BHDH87

Hard Disk Drive - 18GB (Ultra160.7,200rpm)

SCSI Cable(10m) (Hot Plug GP5-HDH88/GP5BHDH88

GP5S-834 Available as of August 20th

Hard Disk Drive - 9GB (Ultra160.7,200rpm)

(Hot Plug GP5-HDH9B/GP5BHDH9B

Available as of August 20th

Redundant Power Supply Unit

GP5UR1PU1/GP5BUR1PU1

Memory

Connect with Storage System

CPU

Internal Hard Disk

teamserver HS900

Page 11: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

11

System Configuration

Max:8 Hard Disk Drive - 36GB (Ultra160.10,000rpm)

6 (Hot Plug)

RAID card Available as of August 20th

cache:32MB SCSI Cable Max:1

Ultra2 Wide SCSI GP5S-832 Storage System Hard Disk Drive - 9GB (Ultra160.10,000rpm)

GP5-144 GP5UR1DC5 (Hot Plug)

RAID card SCSI Cable Hard Disk Drive - 18GB (Ultra160.10,000rpm)

cache:16MB GP5S-835 (Hot Plug)

Ultra2 Wide SCSI

GP5-146

Hard Disk Drive - 18GB (Ultra160.7,200rpm)

SCSI Cable (Hot Plug)

GP5S-836 Available as of August 20th

Hard Disk Drive - 9GB (Ultra160.7,200rpm)

(Hot Plug)

Available as of August 20th

Redundant Power Supply Unit

GP5UR1PU1/GP5BUR1PU1

Up to four Tape units can be mounted

9 SCSI Cable Backup Cabinet DLT unit (DLT7000)

GP5S-832 GP5UR1BC1 GP5-DL351

Occupied two 5" bay slots

DAT unit (DDS4)

GP5-DT401

Tape unit (MLR3)

GP5-ML301

DLT unit (DLT4000)

GP5UDL201

Occupied two 5" bay slots

DAT unit (DDS3)

GP5UDT301

Tape unit (SLR5)

GP5USL501

Redundant Power Supply Unit

GP5UPU151

6 LAN Card

GP5-183

6 LAN Card

GP5-185

6 LAN Card

GP5-187

6 Server Monitor Module

GP5USM103

Others

Page 12: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

12

System Configuration

CPU:Pentium(R)lll(700MHz)x1(~4)/Cache(L1+L2):(32KB+2MB/1MB)/Onboard SCSI(Ultra160x2, UltraWide/Narrowx1)

CD-ROM/LAN (Onboard)/Internal Hard Disk Drive Bay:8~12(Opt.) (Hotplug)

Bundled SW:Servervisor/Intel LANDesk(R) Server Manager/ServerWizard

GP5T6BH1A 1CPU(Pentium(R)lllXeon700MHz/2MB)/Pedestal Type

GP5T6BH1R 1CPU(Pentium(R)lllXeon700MHz/2MB)/Rackmount Type

GP5T6BG1A 1CPU(Pentium(R)lllXeon700MHz/1MB)/Pedestal Type

GP5T6BG1R 1CPU(Pentium(R)lllXeon700MHz/1MB)/Rackmount Type

<Items>

CPU Field upgrade : Go to A

Memory addition : Go to B

Standard memory conversion : Go to C

Pedestal Type Connect HDD (Standard Drive Cage)

1.SCSI configuration Go to D

2. Array configuration Go to E

3. Internal backup device Go to F

Connect HDD (Drive Cage Conversion Kit)

1.SCSI configuration Go to G

2. Array configuration Go to H

3. Internal backup device Go to I

Others (NIC, PSU, etc.) : Go to J

Rackmount Type

A:

1 CPU Field Upgrade Kit (Pentiumlll Xeon 700MHz (2MB) x1)

GP5-FG20H/GP5BFG20H

CPU Field Upgrade Kit (Pentiumlll Xeon 700MHz (1MB) x1)

GP5-FG20G/GP5BFG20G

B:

Max.16GB (1GB DIMM x 16)

2 Additional Memory-4GB (1GB SDRAM-DIMMx4)

Standard : 256MB (64MB-DIMMx4) GP5-RM4N/GP5BRM4N

Additional Memory-2GB(512MB SDRAM-DIMMx4)

GP5-RM2N/GP5BRM2N

Additional Memory-1GB(256MB SDRAM-DIMMx4)

GP5-RM1N/GP5BRM1N

Additional Memory-512MB(128MB SDRAM-DIMMx4)

GP5-RM51N/GP5BRM51N

Additional Memory-256MB(64MB SDRAM-DIMMx4)

GP5-RM25N/GP5BRM25N

C:

2 Standard Memory Conversion Kit-4GB (1GB SDRAM-DIMMx4)

GP5BRU4GA

Standard Memory Conversion Kit-2GB (512GB SDRAM-DIMMx4)

GP5BRU2GC

Standard Memory Conversion Kit-1GB (256GB SDRAM-DIMMx4)

GP5BRU1GF

Standard Memory Conversion Kit-512MB(64MB SDRAM-DIMMx4)

GP5BRU51K

Memory

CPU

PRIMERGY MS610

Standard Memory conversion

Page 13: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

13

System Configuration

(Standard Drive Cage)

Standard Drive Cage

1inch height HDD x 8

D:

Hard Disk Drive-9GB(Ultra160, 7,200rpm)

3 1"height/Hotplug GP5-HDH9B/GP5BHDH9B

Available as of August 20th

Hard Disk Drive-18GB(Ultra160, 7,200rpm)

1"height/Hotplug GP5-HDH88/GP5BHDH88

Available as of August 20th

Hard Disk Drive-9GB(Ultra160,10,000rpm)

1"height/Hotplug

GP5-HDH9A/GP5BHDH9A

Hard Disk Drive-18GB(Ultra160,10,000rpm)

1"height/Hotplug

GP5-HDH87/GP5BHDH87

Hard Disk Drive-36GB(Ultra160,10,000rpm)

1"height/Hotplug GP5-HDH63/GP5BHDH63

Available as of August 20th

E:

6 Go to SCSI Hard Disk Drive as above

RAID Card

(32MB Cache/Ultra2 Wide SCSI)

GP5-144/GP5B144

RAID Card

(16MB Cache/Ultra2 Wide SCSI)

GP5-146/GP5B146

F:

Connect one backup device (Wide)

4 DLT unit (DLT7000)

GP5-DL351/GP5BDL351

Connect secondary backup device (Wide) * Two 5"bays are occupied

6

DAT unit (DDS4)

SCSI Card GP5-DT401/GP5BDT401

GP5-127/GP5B127

If mounting two backup devices (Narrow/Wide), SCSI Card (GP5-127) Tape unit (MLR3)

is required for wide connect device. GP5-ML301/GP5BML301

If mounting two backup devices (Wide/Wide), SCSI Card (GP5-127)

is required for secondary wide connect device.

Max.2 backup devices can be mounted

Backup device (Narrow)

4 DLT unit (DLT4000)

GP5UDL201/GP5BDL201

* Two 5"bays are occupied

DAT unit (DDS3)

GP5UDT301/GP5BDT301

Tape unit

GP5USL501/GP5BSL501

Internal HDD / Internal backup device

SCSI Configuration

Array Configuration

Internal backup device

Page 14: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

14

System Configuration

(When Drive Cage Conversion Kit is used)

Drive Cage Conversion Kit (for CTO only)

(HDD Bay: 8bays to 12bays)

GP5BBU1

G:

3 Hard Disk Drive-9GB(Ultra160, 7,200rpm)

1"height/Hotplug GP5-HDH9B/GP5BHDH9B

Available as of August 20th.

Hard Disk Drive-18GB(Ultra160, 7,200rpm)

1"height/Hotplug GP5-HDH88/GP5BHDH88

Available as of August 20th.

Hard Disk Drive-9GB(Ultra160,10,000rpm)

1"height/Hotplug

GP5-HDH9A/GP5BHDH9A

Hard Disk Drive-18GB(Ultra160,10,000rpm)

1"height/Hotplug

GP5-HDH87/GP5BHDH87

Hard Disk Drive-36GB(Ultra160,10,000rpm)

1"height/Hotplug GP5-HDH63/GP5BHDH63

Available as of August 20th.

H:

6 Go to SCSI Hard Disk Drive as above

RAID Card

(32MB Cache/Ultra2 Wide SCSI/3ch)

GP5-144/GP5B144

RAID Card

(16MB Cache/Ultra2 Wide SCSI/2ch) GP5-146/GP5B146

GP5-143/GP5B143 cannot be used with Drive Cage Conversion Kit (GP5BBU1).

I:

Backup device (Wide)

4 DLT unit (DLT7000)

GP5-DL351/GP5BDL351

SCSI Card * Two 5"bays are occupied

GP5-127/GP5B127

DAT unit (DDS4)

If mounting two backup devices (Narrow/Wide), SCSI Card (GP5-127) GP5-DT401/GP5BDT401

is required for wide connect device.

If mounting two backup devices (Wide/Wide), SCSI Card (GP5-127)

is required for secondary wide connect device. Tape unit (MLR3)

GP5-ML301/GP5BML301

Backup device (Narrow)

4 DLT unit (DLT4000)

GP5UDL201/GP5BDL201

* Two 5"bays are occupied

DAT unit (DDS3)

GP5UDT301/GP5BDT301

Tape unit

GP5USL501/GP5BSL501

Max.2 backup devices can be mounted

SCSI Configuration

Array Configuration

Internal backup device

Page 15: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

15

System Configuration

J:

6 LAN Card

GP5-183/GP5B183

6 LAN Card

GP5-185/GP5B185

6 LAN Card

GP5-186/GP5B186

6 LAN Card

GP5-187/GP5B187

One PSU can be added

6 Redundant Power Supply Unit

GP5UPU161/GP5BUPU161

6 Server Monitor Module

GP5USM103/GP5BUSM103

Others

Page 16: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

16

System Configuration

CPU: Pentium(R) lll (850/800/700/600EMHz) x1(~2) , Cache (L1+L2) : 32KB+256KB, On board SCSI,

CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 8bays (Hot-plug), Servervisor/ Intel LANDesk Server Manager, Server Wizard

PRMIERGY MS380 GP5G804L 1CPU/Pedestal Type 1CPU (Pentium(R)lll 850MHz), Memory:256MB(ECC), HDD:Option

GP5G804LR 1CPU/Rackmount Type 1CPU (Pentium(R)lll 850MHz), Memory:256MB(ECC), HDD:Option

GP5G803L 1CPU/Pedestal Type 1CPU (Pentium(R)lll 800EMHz), Memory:256MB(ECC), HDD:Option

GP5G803LR 1CPU/Rackmount Type 1CPU(Pentium(R)lll 800EMHz), Memory:256MB(ECC), HDD:Option

(Pedestal type ) GP5G802L 1CPU/Pedestal Type 1CPU(Pentium(R)lll 700MHz), Memory:256MB(ECC), HDD:Option

GP5G802LR 1CPU/Rackmount Type 1CPU(Pentium(R)lll 700MHz), Memory:256MB(ECC), HDD:Option

GP5G801L 1CPU/Pedestal Type 1CPU(Pentium(R)lll 600EMHz), Memory:256MB(ECC), HDD:Option

(Rackmount type)

GP5G801LR 1CPU/Rackmount Type 1CPU(Pentium(R)lll 600EMHz), Memory:256MB(ECC), HDD:Option

Max : 2CPUs CPU Field Upgrade Kit-63 (Pentium III-850MHz (256KB) x1)

1 GP5-FG20C/GP5BFG20C

CPU Field Upgrade Kit-62 (Pentium III-800MHz (256KB) x1)

GP5-FG20B/GP5BFG20B

CPU Field Upgrade Kit-56 (Pentium III-700MHz (256KB) x1)

GP5-FG205/GP5BFG205

CPU Field Upgrade Kit-57 (Pentium III-600EMHz (256KB) x1)

GP5-FG12Y/GP5BFG12Y

Max.2GB

2 Additional Memory - 64MB (64MB SDRAM-DIMM x1)

Standard memory : 256MB (256MB SDRAM-DIMM x1) GP5-RM64F/GP5BRM64F

Additional Memory -128MB (128MB SDRAM-DIMM x1)

GP5-RM12F/GP5BRM12F

Additional Memory - 256MB (256MB SDRAM-DIMM x1)

GP5-RM25F/GP5BRM25F

Additional Memory - 512 MB( 512MB SDRAM-DIMMx1)

GP5-RM51F/GP5BRM51F

2 Standard Memory Conversion Kit-512MB ( 512MB SDRAM-DIMMx1)

GP5BRU51F

(1)Disk Addition / Duplexing Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) : max 6

3 (Hot Plug)

Up to 8 disks GP5-HDH9A/GP5BHDH9A

Hard Disk Drive -18GB (Ultra2 Wide.10,000rpm) : max 6

(Hot Plug)

GP5-HDH87/GP5BHDH87

Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)

(Hot Plug)

GP5-HDH96/GP5BHDH96

Hard Disk Drive -18GB (Ultra2 Wide.7,200rpm)

(Hot Plug)

GP5-HDH83/GP5BHDH83

Memory

CPU

Internal Hard Disk

PRIMERGY MS380

Standard Memory Conversion Option

Page 17: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

17

System Configuration

(2)Internal Disk Array

Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm) : max 6

6 RAID Card (Cache : 32MB, Ultra2 Wide SCSI, BBU) (Hot Plug)

GP5-144/GP5B144 GP5-HDH9A/GP5BHDH9A

RAID Card (Cache :16MB, Ultra2 Wide SCSI, BBU) Hard Disk Drive -18GB (Ultra2 Wide.10,000rpm) : max 6

GP5-146/GP5B146 (Hot Plug)

GP5-HDH87/GP5BHDH87

Hard Disk Drive - 9GB (Ultra2 Wide.7,200rpm)

(Hot Plug)

GP5-HDH96/GP5BHDH96

Hard Disk Drive -18GB (Ultra2 Wide.7,200rpm)

(Hot Plug)

GP5-HDH83/GP5BHDH83

6 DLT unit (DLT7000)*(Occupied two 5" bay slots)

GP5-DL351/GP5BDL351

SCSI Card

GP5-127/GP5B127

Tape unit (MLR3)

GP5-ML301/GP5BML301

*NOTE : 2 PSUs are required as standard if GP5-DL351 is installed

Maximum 3PSUs can be installed in MS380.

DAT unit (DDS4)

GP5-DT401/GP5BDT401

4 DLT unit (DLT4000)(Occupied two 5" bay slots)

GP5UDL201/GP5BDL201

DAT unit (DDS3)

GP5UDT301/GP5BDT301

Tape unit (SLR5)

GP5USL501/GP5BSL501

6 LAN Card

GP5-183/GP5B183

6 LAN Card

GP5-185/GP5B185

6 LAN Card

GP5-187/GP5B187

8 Redundant Power Supply Unit

GP5UPU131/GP5BUPU131

6 Server Monitor Module

GP5USM103/GP5BUSM103 *NOTE : 2 PSUs are required as standard if GP5-DL351 is installed

Maximum 3PSUs can be installed in MS380.

Internal Devices

Others

Page 18: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

18

System Configuration

CPU: Pentium (R)lll (800/700/600EMHz)x1(~2) ,Cache (L1+L2) : 32KB+256KB,

On board SCSI, CD-ROM, Onboard LAN (Std.), Internal Hard disk bay: 4bays (3xHot-plug),

PRIMERGY ES280 Bundled SW : Servervisor/ Intel LANDesk Server Manager, ServerWizard

GP5C803 1CPU/Pedestal Type 1CPU (Pentium(R)lll 800MHz), Memory:128MB(ECC), HDD:Option

GP5C803R 1CPU/Rackmount Type 1CPU (Pentium(R)lll 800MHz), Memory:128MB(ECC), HDD:Option

GP5C802 1CPU/Pedestal Type 1CPU (Pentium(R)lll 700MHz), Memory:128MB(ECC), HDD:Option

(Pedestal type ) GP5C802R 1CPU/Rackmount Type 1CPU (Pentium(R)lll 700MHz), Memory:128MB(ECC), HDD:Option

GP5C801 1CPU/Pedestal Type 1CPU (Pentium(R)lll 600EMHz), Memory:128MB(ECC), HDD:Option

GP5C801R 1CPU/Rackmount Type 1CPU (Pentium(R)lll 600EMHz), Memory:128MB(ECC), HDD:Option

(Rackmount type)

Max : 2CPUs

1 CPU Field Upgrade Kit-62 (Pentium III-800MHz (256KB) x1)

GP5-FG20B/GP5BFG20B

CPU Field Upgrade Kit-56 (Pentium III-700MHz (256KB) x1)

GP5-FG205/GP5BFG205

CPU Field Upgrade Kit-57 (Pentium III-600EMHz (256KB) x1)

GP5-FG12Y/GP5BFG12Y

Max.1GB

2 Additional Memory - 64MB (64MB SDRAM-DIMMx1)

Standard : 128MB (128MB SDRAM-DIMMx1) GP5-RM64F/GP5BRM64F

Additional Memory - 128MB (128MB SDRAM-DIMMx1)

GP5-RM12F/GP5BRM12F

Additional Memory - 256MB (256MB SDRAM-DIMMx1)

GP5-RM25F/GP5BRM25F

Standard Memory Conversion Kit-256MB

2 (256MB SDRAM-DIMMx1)

GP5BRU25E

Total 4 disks(3Hot Plug and1non-Hot Plug)Can be installed.

(1)Disk Addition to Hot Plug bays (Max . 3 disks)

6 Hard Disk Drive - 9GB (Ultra Wide.7,200rpm)(Hot Plug)

GP5-HDH96/GP5BHDH96

Hard Disk Drive -18GB (Ultra Wide.7,200rpm)(Hot Plug)

GP5-HDH83/GP5BHDH83

(2)Internal Disk Array (Maximum 3Hot Plug disksCan be installed)

6 Hard Disk Drive - 9GB (Ultra Wide.7,200rpm)(Hot Plug)

RAIDCard (Cache :16MB) GP5-HDH96/GP5BHDH96

GP5U141/GP5BU141

GP5U831/GP5B831

SCSICable (Intl.) Hard Disk Drive -18GB (Ultra Wide.7,200rpm)(Hot Plug)

RAIDCard (Cache : 8MB Internal Hard disk only) GP5-HDH83/GP5BHDH83

GP5-143/GP5B143

Memory

CPU

Internal Hard Disk

PRIMERGY ES280

Standard Memory Conversion Option

Page 19: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

19

System Configuration

(3)Disk Addition to a non-Hot Plug bay only one diskCan be installed

3 Hard Disk Drive - 9GB (7,200rpm) (non-Hot Plug)

GP5-HD9G3/GP5BHD9G3

Hard Disk Drive -18GB (7,200rpm) (non-Hot Plug)

GP5-HD8G1/GP5BHD8G1

6 Tape unit (MLR3)

GP5-ML301/GP5BML301

SCSI Card

GP5-125/GP5B125

DAT unit (DDS4)

GP5-DT401/GP5BDT401

4 DAT unit (DDS3)

GP5UDT301/GP5BDT301

s Tape unit (SLR5)

GP5USL501/GP5BSL501

6 LAN Card

GP5-183/GP5B183

6 LAN Card

GP5-185/GP5B185

6 LAN Card

GP5-187/GP5B187

6 Server Monitor Module

GP5USM103/GP5BUSM103

Internal Devices

Others

Page 20: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

20

System Configuration

CPU:Pentium(R)lll(850/700/600EMHz)x1(~2),Cache(L1+L2):32KB+256KBx2/Onboard SCSI(1xUltra Wide, 1xFast Narrow)

3PCI(32bit33MHz)/CD-ROM/Onboard LAN(Std.)/Internal Hard Disk Drive Bay:4 (Non Hotplug)

Bundled S/W: Servervisor/Intel LANDesk(R) Server Manager/ServerWizard

GP5T2BC1A: 1CPU(Pentium(R)lll850MHz)/Pedestal Type

GP5T2B51A: 1CPU(Pentium(R)lll700MHz)/Pedestal Type

GP5T2BY1A: 1CPU(Pentium(R)lll600EMHz)/Pedestal Type

<Items>

CPU Field Upgrade : Go to A

Memory addition : Go to B

Standard memory conversion : Go to C

SCSI configuration

Internal Hard Disk Drive (Ultra Wide) : Go to D

Internal Hard Disk Drive (Ultra2 Wide) : Go to E

Internal backup device : Go to F

IDE/Array configuration

Internal Hard Disk Drive (IDE) : Go to G

Internal Hard Disk Drive (Array) : Go to H

Internal backup device : Go to I

Others (NIC, PSU, etc.) : Go to J

A:

1 CPU Field Upgrade Kit-63(Pentiumlll 850MHz(256KB)x1)

GP5-FG20C/GP5BFG20C

CPU Field Upgrade Kit-56 (Pentiumlll 700MHz(256KB)x1)

GP5-FG205/GP5BFG205

CPU Field Upgrade Kit-57(Pentiumlll 600EMHz(256KB)x1)

GP5-FG12Y/GP5BFG12Y

B:

Max:1GB(256MB SDRAM-DIMM x 4)

2 Additional Memory-64MB (64MB SDRAM-DIMMx1)

Standard:128MB (128MB SDRAM-DIMMx1) GP5-RM64H/GP5BRM64H

Additional Memory-128MB (128MB SDRAM-DIMMx1)

GP5-RM12H/GP5BRM12H

Additional Memory-256MB (256MB SDRAM-DIMMx1)

C: GP5-RM25H/GP5BRM25H

Standard Memory conversion option

2 Standard Memory Conversion Kit-256MB (256MB SDRAM-DIMMx1)

GP5BRU25D

(SCSI Configuration)

D:

Ultra Wide Max: 4 HDDs

Hard Disk Drive-9GB(Ultra2 Wide SCSI,7,200rpm)

Onboard SCSI GP5-HD9G3/GP5BHD9G3 (For HDD bay:Up to 3HDDs can be mounted)

SCSI Cable GP5-HD9G3C /GP5BHD9G3C (For 5"bay:Only one can be mounted)

E: GP5-843/GP5B843

Ultra2 Wide

6 Hard Disk Drive-18GB(Ultra2 Wide SCSI,7,200rpm)

GP5-HD8G1/GP5BHD8G1 (For HDD bay:Up to 3HDDs can be mounted)

SCSI Card GP5-HD8G1C/GP5BHD8G1C(For 5"bay:Only one can be mounted)

GP5-127/GP5B127

Memory

Internal HDD / Internal backup device

CPU

PRIMERGY ES210

Page 21: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

21

System Configuration

F:

DAT unit(DDS3)

GP5UDT301/GP5BDT301

Max.2 backup devices can be mounted

6 DAT unit(DDS4)

GP5-DT401/GP5BDT401

SCSI Card

GP5-127/GP5B127 SCSI Cable is supplied with wide backup devices.

G:

(IDE configuration) Max:2 IDE Disk can be mounted

3 Hard Disk Drive-20GB(Ultra33/DMA,5,400rpm)

GP5-HD2E1/GP5BHD2E1

H:

(Array configuration)

6 Go to SCSI Hard Disk Drive as above

RAID Card

(8MB Cache, Ultra2 Wide SCSI, SCSI Cable

Only for internal HDD connection) GP5-843/GP5B843

I: GP5-143/GP5B143

6 DAT unit (DDS3)

GP5UDT301/GP5BDT301

SCSI Card (GP5-127/GP5B127) is required for mounting

Wide connect backup device.

6 DAT unit (DDS4)

GP5-DT401/GP5BDT401

SCSI Card SCSI Cable is a standard equipment of backup device

GP5-127/GP5B127

J:

6 LAN Card

GP5-183/GP5B183

6 LAN Card

GP5-185/GP5B185

6 LAN Card

GP5-187/GP5B187

6 Server Monitor Module

GP5USM103/GP5BUSM103

Max.2 backup devices can be mounted

Others

Page 22: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

22

System Configuration

CPU:Pentium(R)lll(600EMHz),Cache(L1+L2):32KB+256KB/Celeron(500MHz)x1,Cache(L1+L2):32KB+128KB

4PCI(32bit33MHz)/CD-ROM/Onboard LAN(Std.)/Internal Hard Disk Drive Bay:4 (Non Hotplug)

Bundled S/W: Servervisor/Intel LANDesk(R) Server Manager/ServerWizard

GP5T2AY1A 1CPU(Pentium(R)lll600EMHz)/Pedestal Type

GP5T2AF1A 1CPU(Celeron(R)500MHz)/Pedestal Type

<Items>

Memory addition : GoTo A

Standard memory conversion : GoTo B

SCSI configuration

Internal Hard Disk Drive (Ultra Wide) : GoTo C

Internal backup device : GoTo D

IDE/Array configuration

Internal Hard Disk Drive (IDE) : GoTo E

Internal Hard Disk Drive (Array) : GoTo F

Internal backup device : GoTo G

Others (NIC, PSU, etc.) : GoTo H

A:

Max:768MB (256MB SDRAM-DIMM x3)

2 Additional Memory-64MB (64MB SDRAM-DIMMx1)

Standard:128MB (128MB SDRAM-DIMMx1) GP5-RM64H/GP5BRM64H

Additional Memory-128MB (128MB SDRAM-DIMMx1)

GP5-RM12H/GP5BRM12H

Additional Memory-256MB (256MB SDRAM-DIMMx1)

B: GP5-RM25H/GP5BRM25H

Standard Memory conversion option

2 Standard Memory Conversion Kit-256MB (256MB SDRAM-DIMMx1)

GP5BRU25D

C: (SCSI Configuration)

Max:Four HDDs

6 Hard Disk Drive-9GB(Ultra2 Wide SCSI,7,200rpm)

GP5-HD9G3/GP5BHD9G3 (For HDD bay:Up to 3HDDs can be mounted)

SCSI Card SCSI Cable GP5-HD9G3C/GP5BHD9G3C (For 5"bay:Only one can be mounted)

GP5-126/GP5B126 GP5-843/GP5B843

Hard Disk Drive-18GB(Ultra2 Wide SCSI,7,200rpm)

GP5-HD8G1/GP5BHD8G1 (For HDD bay:Up to 3HDDs can be mounted)

GP5-HD8G1C/GP5BHD8G1C(For 5"bay:Only one can be mounted)

DAT unit (DDS3)

GP5UDT301/GP5BDT301

SCSI Cable Only one DDS3 can be mounted in "bay2"

GP5-841/GP5B841

Tape unit

GP5USL501/GP5BSL501

D:

6 DAT unit (DDS4)

GP5-DT401/GP5BDT401

SCSI Card SCSI Cable

GP5-127/GP5B127 GP5-840/GP5B840 Tape unit (MLR3)

GP5-ML301/GP5BML301

E:

(IDE configuration) Max:2 IDE Disk can be mounted

3 Hard Disk Drive-20GB(Ultra33/DMA,5,400rpm)

GP5-HD2E1/GP5BHD2E1

Memory

Internal HDD / Internal backup device

Max.2 backup devices can be mounted

PRIMERGY ES200

Page 23: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

23

System Configuration

F:

(Array configuration)

6 Go to SCSI Hard Disk Drive as above

RAID Card

(8MB Cache, Ultra2 Wide SCSI, SCSI Cable

Only for internal HDD connection) GP5-843/GP5B843

GP5-143/GP5B143

SCSI Card (GP5-127/GP5B127) is required for mounting backup devices as shown below.

G:

6 DAT unit (DDS3)

SCSI Card GP5UDT301/GP5BDT301

GP5-127/GP5B127 SCSI Cable

GP5-840/GP5B840

Tape unit

GP5USL501/GP5BSL501

DAT unit (DDS4)

GP5-DT401/GP5BDT401

SCSI Cable is supplied as standard equipment with wide backup devices. Tape unit (MLR3)

GP5-ML301/GP5BML301

H:

6 LAN Card

GP5-183/GP5B183

6 LAN Card

GP5-185/GP5B185

6 LAN Card

GP5-187/GP5B187

6 Server Monitor Module

GP5USM103/GP5BUSM103

PRIMERGY HS900 / MS610 / MS380

11 SCSI Card SCSI Cable

GP5-123 (Procured locally)

Max.2 backup devices can be mounted

Others

External Disk Array

Page 24: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

24

System Configuration

(Pedestal only)

Disk addition

6 SCSI card SCSI cable

GP5-125/GP5B125 GP5MU823A

Disk array

6 RAID card(cache:16MB) SCSI cable

GP5U141/GP5BU141 GP5MU829A

Disk addition

6 6 6 SCSI card SCSI cable Hard disk cabinet

GP5-127/GP5B127 GP5MU823A GP5MS623A

Disk array

6 6 RAID card(cache:32MB) SCSI cable

GP5-144/GP5B144 GP5S-832

Disk array

6 6 6 RAID card(cache:16MB) SCSI cable

GP5-146/GP5B146 GP5S-832

Configuration of the inside Hard disk cabinet

Hard Disk Drive-9GB Hard Disk Drive-18GB

(7,200rpm) (10,000rpm)

GP5-HDH9B/GP5BHDH9B GP5-HDH87/GP5BHDH87

Available as of August 20th

Hard Disk Drive-36GB

Hard Disk Drive-9GB (10,000rpm)

(10,000rpm) GP5-HDH63/GP5BHDH63

GP5-HDH9A/GP5BHDH9A Available as of August 20th

Hard Disk Drive-18GB

(7,200rpm) Power Supply Unit

GP5-HDH88/GP5BHDH88 GP5URIPU1/GP5BUR1PU1

Available as of August 20th

External Devices

Hard disk cabinetES210

ES200

MS380

ES280

MS380 only

MS380 only

MS380 only

ES280 only

HS900

MS610

ES280 only

Page 25: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

25

System Configuration

Rack Mount Pattern 40U Rack 40U Rack & Rack Coupling Kit

GP5-RMP GP5-R1RC4 GP5-R1RC5

CPU or DISK node

24U Rack 24U Rack & Rack Coupling Kit

GP5-R2RC1 GP5-R2RC2

Component Shelf GP5-R1TB4

Keyboard/Monitor Shelf Kit

GP5-R1TB5 (For GP5-R2RC1/GP5-R1RC4)

(Up to 8 servers connection)

Keyboard/Monitor Cable Keyboard/Monitor Enhanced Switch Flat Display

GP5-418(5.0m) GP5-SB102 GP5UR1DP1

(Up to 4 servers connection)

Keyboard/Monitor Cable Keyboard/Monitor Enhanced Switch Enhanced Keyboard

GP5-411 (3.0m) GP5-SB101 GP5-R1KB2

Power Distribution Unit

Up to eight servers can be connected to one GP5-SB102, and up to GP5UPDU1

64 servers can be connected with nine GP5-SB102 in cascade connection

(Keyboard Monitor Cable: GP5-414 is required)

GP5-SB102 GP5-SB102

GP5-414

6 Storage System

SCSI card SCSI Cable GP5UR1DC5

GP5-125/GP5B125 GP5MU823A

6

RAID card* SCSI Cable

GP5U141/GP5BU141 GP5MU829A

6 6

SCSI card SCSI Cable

GP5-127/GP5B127 GP5MU823A/GP5S-833/834

6 6

RAID card SCSI Cable

GP5-144/GP5B144 GP5S-832/835/836

6 6

RAID card SCSI Cable

GP5-146/GP5B146 GP5S-832/835/836

Rackmount

HS900MS610

MS380 only

MS380 only

MS380 only

ES280 only

MS380ES280

ES280 only

Rack Option

Page 26: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

26

System Configuration

Inside of Storage SystemHard Disk Drive-9GB Hard Disk Drive-18GB

(7,200rpm) (10,000rpm)

GP5-HDH9B/GP5BHDH9B GP5-HDH87/GP5BHDH87

Available as of August 20th

Hard Disk Drive-36GB

Hard Disk Drive-9GB (10,000rpm)

(10,000rpm) GP5-HDH63/GP5BHDH63

GP5-HDH9A/GP5BHDH9A Available as of August 20th

Hard Disk Drive-18GB

(7,200rpm) Power Supply Unit

GP5-HDH88/GP5BHDH88 GP5URIPU1/GP5BUR1PU1

Available as of August 20th

NOTE A maximum of eight Hard Disk Drives can be installed in a Storage System.

In a RAID configuration, a physical pack must be comprised

of the same type of Hard disks.

Page 27: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

27

Hardware

Product Product ID Remarks

teamserver HS900 GP5T9A32R Pentium lll Xeon 550MHz with 2MB Cache (x2, up to 8CPUs) , 1GB SDRAM-DIMM(128MBx8) with ECC ( 32GB maximum )

(Rackmount) # of HDD Bay: 2(Hotplug) [Up to twelve Storage System(GP5UR1DC4) can be mounted as external storage]/32Xspeed CD-ROM /LAN Card(Std.)

Onboard SCSI:Ultra2 Widex2/ 10PCI(4x64bit66MHz, 6x64bit/33MHz) Redundant&Hotplug PSU(Std.), Redundant&Hotplug&Proactive Fan(Std.)

Rackmount7U, Servervisor/LANDesk Server Manager/Server Wizard

teamserver HS900 GP5T9A22R Pentium lll Xeon 550MHz with 1MB Cache (x2, up to 8CPUs) , 1GB SDRAM-DIMM(128MBx8) with ECC ( 32GB maximum )

(Rackmount) # of HDD Bay: 2(Hotplug) [Up to twelve Storage System(GP5UR1DC4) can be mounted as external storage]/32Xspeed CD-ROM /LAN Card(Std.)

Onboard SCSI:Ultra2 Widex2/ 10PCI(4x64bit66MHz, 6x64bit/33MHz) Redundant&Hotplug PSU(Std.), Redundant&Hotplug&Proactive Fan(Std.)

Rackmount7U, Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS610 GP5T6BH1A Pentium lll Xeon 700MHz with 2MB Cache (x1, up to 4CPUs) , 256MB SDRAM-DIMM(64MBx4) with ECC, ( 16GB maximum )

(Pedestal) # of HDD Bay: 8(Hotplug) [12(Hotplug): When drive cage conversion (GP5BBU1)]/40Xspeed CD-ROM /LAN Card(Onboard)/

(End July 2000) Onboard SCSI:Ultra160x2, Wide or Narrowx1/8PCI(2x64bit66MHz, 4x64bit/33MHz, 2x32bit/33MHz)

Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS610 GP5T6BH1R Pentium lll Xeon 700MHz with 2MB Cache (x1, up to 4CPUs) , 256MB SDRAM-DIMM(64MBx4) with ECC, ( 16GB maximum )

(Rackmount) # of HDD Bay: 8(Hotplug) [12(Hotplug): When drive cage conversion (GP5BBU1)]/40Xspeed CD-ROM /LAN Card(Onboard)/

(End July 2000) Onboard SCSI:Ultra160x2, Wide or Narrowx1/8PCI(2x64bit66MHz, 4x64bit/33MHz, 2x32bit/33MHz)

Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS610 GP5T6BG1A Pentium lll Xeon 700MHz with 1MB Cache (x1, up to 4CPUs) , 256MB SDRAM-DIMM(64MBx4) with ECC, ( 16GB maximum )

(Pedestal) # of HDD Bay: 8(Hotplug) [12(Hotplug): When drive cage conversion (GP5BBU1)]/40Xspeed CD-ROM /LAN Card(Onboard)/

(End July 2000) Onboard SCSI:Ultra160x2, Wide or Narrowx1/8PCI(2x64bit66MHz, 4x64bit/33MHz, 2x32bit/33MHz)

Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS610 GP5T6BG1R Pentium lll Xeon 700MHz with 1MB Cache (x1, up to 4CPUs) , 256MB SDRAM-DIMM(64MBx4) with ECC, ( 16GB maximum )

(Rackmount) # of HDD Bay: 8(Hotplug) [12(Hotplug): When drive cage conversion (GP5BBU1)]/40Xspeed CD-ROM /LAN Card(Onboard)/

(End July 2000) Onboard SCSI:Ultra160x2, Wide or Narrowx1/8PCI(2x64bit66MHz, 4x64bit/33MHz, 2x32bit/33MHz)

Redundant&Hotplug PSU(Opt.)/Redundant&Hotplug&Proactive Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS380 GP5G804L Pentium lll850MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Pedestal) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS380 GP5G804LR Pentium lll850MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS380 GP5G803L Pentium lll800MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Pedestal) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS380 GP5G803LR Pentium lll800MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS380 GP5G802L Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Pedestal) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS380 GP5G802LR Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

Page 28: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

28

Hardware

Product Product ID Remarks

PRIMERGY MS380 GP5G801L Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Pedestal) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY MS380 GP5G801LR Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 256MB SDRAM (256MB x1) with ECC (2GB maximum)

(Rackmount) # of HDD Bay: 8(Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:Ultra2Widex2, Narrowx1

(End July 2000) 32bit/33MHzPCIx4, PCI/ISAx1, ISAx1/Redundant&Hotplug PSU(Opt.), Redundant&Hotplug Fan(Std.)

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES280 GP5C803 Pentium lll800MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MB x1) with ECC (1GB maximum)

(Pedestal) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

(End July 2000) 32bit/33MHzPCIx3, ISAx2

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES280 GP5C803R Pentium lll800MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MB x1) with ECC (1GB maximum)

(Rackmount) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

(End July 2000) 32bit/33MHzPCIx3, ISAx2

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES280 GP5C802 Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MB x1) with ECC (1GB maximum)

(Pedestal) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

(End July 2000) 32bit/33MHzPCIx3, ISAx2

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES280 GP5C802R Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MB x1) with ECC (1GB maximum)

(Rackmount) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

(End July 2000) 32bit/33MHzPCIx3, ISAx2

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES280 GP5C801 Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MB x1) with ECC (1GB maximum)

(Pedestal) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

(End July 2000) 32bit/33MHzPCIx3, ISAx2

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES280 GP5C801R Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MB x1) with ECC (1GB maximum)

(Rackmount) # of HDD Bay: 4(3Hotplug)/32Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

(End July 2000) 32bit/33MHzPCIx3, ISAx2

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES210 GP5T2BC1A Pentium lll850MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC (1GB maximum )

(Pedestal) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay + 2xSCSI bay(SCSI/EIDE HDD both can be mounted)

(End Jun 2000) 40Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES210 GP5T2B51A Pentium lll700MHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC (1GB maximum )

(Pedestal) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay + 2xSCSI bay(SCSI/EIDE HDD both can be mounted)

(End Jun 2000) 40Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES210 GP5T2BY1A Pentium lll600EMHz with 256KB Cache (x1, up to 2CPUs) , 128MB SDRAM (128MBx1) with ECC (1GB maximum )

(Pedestal) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay + 2xSCSI bay(SCSI/EIDE HDD both can be mounted)

(End Jun 2000) 40Xspeed CD-ROM /Onboard LAN/Onboard SCSI:UltraWidex1, Narrowx1

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES200 GP5T2AY1A2 Pentium lll600EMHz with 256KB Cache (x1) , 128MB SDRAM (128MBx1) with ECC (768MB maximum )

(Pedestal) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay(Use one 5"Bay) + 2xSCSI bay(SCSI/EIDE HDD both can be mounted)

(End Jun 2000) 40Xspeed CD-ROM /Onboard LAN

Servervisor/LANDesk Server Manager/Server Wizard

PRIMERGY ES200 GP5T2AF1A2 Celeron500MHz with 128KB Cache (x1) , 128MB SDRAM (128MBx1) with ECC (768MB maximum )

(Pedestal) # of HDD Bay: 4(Non hotplug)[2xSCSI Bay(Use one 5"Bay) + 2xSCSI bay(SCSI/EIDE HDD both can be mounted)

(End Jun 2000) 40Xspeed CD-ROM /Onboard LAN

Servervisor/LANDesk Server Manager/Server Wizard

Page 29: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

29

Hardware

Hardware List

HS900 MS610 MS380 ES280 ES210 ES200

ProductProduct ID(Overseasinc.Korea)

GP

5T9A

32R

GP

5T9A

22R

GP

5T6B

H1A

(R)

GP

5T6B

G1A

(R)

GP

5G80

4L(R

)

GP

5G80

3L(R

)

GP

5G80

2L(R

)

GP

5G80

1L(R

)

GP

5C80

3(R

)

GP

5C80

2(R

)

GP

5C80

1(R

)

GP

5T2B

C1A

GP

5T2B

51A

GP

5T2B

Y1A

GP

5T2A

Y1A

2

GP

5T2A

F1A

2

Remarks

CPU Field Upgrade Kit GP5-FG203T ■ Pentiumlll Xeon(550MHz)/32KB+2MBcachex1,Placed on motherboard

Includes one CPU, For HS900

CPU Field Upgrade Kit GP5-FG202T ■ Pentiumlll Xeon(550MHz)/32KB+1MBcachex1,Placed on motherboard

Includes one CPU, For HS900

CPU Field Upgrade Kit-68 GP5-FG20H ■ Pentiumlll Xeon(700MHz)/32KB+2MBcachex1,Placed on motherboard

GP5BFG20H Includes one CPU, For MS610

[CTO option]

CPU Field Upgrade Kit-67 GP5-FG20G ■ Pentiumlll Xeon(700MHz)/32KB+1MBcachex1,Placed on motherboard

GP5BFG20G Includes one CPU, For MS610

[CTO option]

CPU Field Upgrade Kit-63 GP5-FG20C ■ ■ Pentiumlll(850MHz)/32KB+256KB x1, for ES210/MS380

GP5BFG20C Cannot be used with other frequency and L2cache processor

[CTO option]

CPU Field Upgrade Kit-62 GP5-FG20B ■ ■ Pentiumlll(800MHz)/32KB+256KB x1, for ES280/MS380

GP5BFG20B Cannot be used with other frequency and L2cache processor

[CTO option]

CPU Field Upgrade Kit-56 GP5-FG205 ■ ■ ■ Pentiumlll(700MHz)/32KB+256KB x1, for ES210/ES280/MS380

GP5BFG205 Cannot be used with other frequency and L2cache processor

[CTO option]

CPU Field Upgrade Kit-57 GP5-FG12Y ■ ■ ■ Pentiumlll(600EMHz)/32KB+256KB x1, for ES210/ES280/MS380

GP5BFG12Y Cannot be used with other frequency and L2cache processor

[CTO option]

Additional Memory 2GB GP5-RM2J ■ ■ SDRAM-DIMM (100MHz) 1024MBx2 (Buffered CL/2)

Additional Memory 1GB GP5-RM1J ■ ■ SDRAM-DIMM (100MHz) 512MBx2 (Buffered CL/2)

Additional Memory 512MB GP5-RM51J ■ ■ SDRAM-DIMM (100MHz) 256MBx2 (Buffered CL/2)

Additional Memory 256MB GP5-RM25J ■ ■ SDRAM-DIMM (100MHz) 128MBx2 (Buffered CL/2)

Additional Memory Board GP5-RB201 ■ ■ Additional memory board for mounting more than 16 DIMMs

Additional Memory 4GB GP5-RM4N ■ ■ SDRAM-DIMM (100MHz) 1GBx4 (Buffered CL/2)

GP5BRM4N Available as of beginning Sep.

[CTO option]

Additional Memory 2GB GP5-RM2N ■ ■ SDRAM-DIMM (100MHz) 512MBx4 (Buffered CL/2)

GP5BRM2N

[CTO option]

Additional Memory 1GB GP5-RM1N ■ ■ SDRAM-DIMM (100MHz) 256MBx4 (Buffered CL/2)

GP5BRM1N

[CTO option]

Additional Memory 512MB GP5-RM51N ■ ■ SDRAM-DIMM (100MHz) 128MBx4 (Buffered CL/2)

GP5BRM51N

[CTO option]

Additional Memory 256MB GP5-RM25N ■ ■ SDRAM-DIMM (100MHz) 64MBx4 (Buffered CL/2)

GP5BRM25N

[CTO option]

Standard Memory Conversion Kit-4GB GP5BRU4GA ■ ■ Standard Memory conversion 256MB to 4GB

[CTO option]

Standard Memory Conversion Kit-2GB GP5BRU2GC ■ ■ Standard Memory conversion 256MB to 2GB

[CTO option]

Standard Memory Conversion Kit-1GB GP5BRU1GF ■ ■ Standard Memory conversion 256MB to 1GB

[CTO option]

Standard Memory Conversion Kit-512MB GP5BRU51K ■ ■ Standard Memory conversion 256MB to 512MB

[CTO option]

Additional Memory 512MB GP5-RM51F ■ ■ ■ ■ SDRAM-DIMM (100MHz) 512MBx1 (Buffered CL/3)

GP5BRM51F

[CTO option]

Additional Memory 256MB GP5-RM25F ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM (100MHz) 256MBx1 (Buffered CL/3)

GP5BRM25F

[CTO option]

Additional Memory 128MB GP5-RM12F ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM (100MHz) 128MBx1 (Buffered CL/3)

GP5BRM12F

[CTO option]

Additional Memory 64MB GP5-RM64F ■ ■ ■ ■ ■ ■ ■ SDRAM-DIMM (100MHz) 64MBx1 (Buffered CL/3)

GP5BRM64F

[CTO option]

Standard Memory Conversion Kit-512MB GP5BRU51F ■ ■ ■ ■ Standard Memory conversion 256MB to 512MB

[CTO option]

Standard Memory Conversion Kit-256MB GP5BRU25E ■ ■ ■ Standard Memory conversion 128MB to 256MB

[CTO option]

Page 30: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

Hardware

HS900 MS610 MS380 ES280 ES210 ES200

ProductProduct ID(Overseasinc.Korea)

GP

5T9A

32R

GP

5T9A

22R

GP

5T6B

H1A

(R)

GP

5T6B

G1A

(R)

GP

5G80

4L(R

)

GP

5G80

3L(R

)

GP

5G80

2L(R

)

GP

5G80

1L(R

)

GP

5C80

3(R

)

GP

5C80

2(R

)

GP

5C80

1(R

)

GP

5T2B

C1A

GP

5T2B

51A

GP

5T2B

Y1A

GP

5T2A

Y1A

2

GP

5T2A

F1A

2

Remarks

Additional Memory 256MB GP5-RM25H ■ ■ ■ ■ ■ SDRAM-DIMM (100MHz) 256MBx1 (Unbuffered CL/3)

GP5BRM25H

[CTO option]

Additional Memory 128MB GP5-RM12H ■ ■ ■ ■ ■ SDRAM-DIMM (100MHz) 128MBx1 (Unbuffered CL/3)

GP5BRM12H

[CTO option]

Additional Memory 64MB GP5-RM64H ■ ■ ■ ■ ■ SDRAM-DIMM (100MHz) 64MBx1 (Unbuffered CL/3)

GP5BRM64H

[CTO option]

Standard Memory GP5BRU25D ■ ■ ■ ■ ■ Standard Memory conversion 128MB to 256MB

Conversion Kit-256MB [CTO option]

Hard Disk Drive-36GB GP5-HDH61T ■ ■ 1.6"height/36.4GB/Ultra2wide SCSI/10000rpm/SCA2 80pin/Hotplug/SMART

Hard Disk Drive-18GB GP5-HDH85T ■ ■ 1"height/18.2GB/Ultra2wide SCSI/10000rpm/SCA2 80pin/Hotplug/SMART

Hard Disk Drive-9GB GP5-HDH98T ■ ■ 1"height/9.1GB/Ultra2wide SCSI/10000rpm/SCA2 80pin/Hotplug/SMART

Hard Disk Drive-36GB GP5-HDH63 ■ ■ 1"height/36.4GB/Ultra160/10000rpm/SCA2/80pin/Hotplug/SMART

GP5BHDH63 For MS610, Storage System (GP5UR1DC5), Hard Disk Cabinet(GP5MS623A)

[CTO option] Available as of August 20th

Hard Disk Drive-18GB GP5-HDH87 ■ ■ ■ ■ ■ ■ 1"height/18.2GB/Ultra160/10000rpm/SCA2/80pin/Hotplug/SMART

GP5BHDH87 For MS610, Storage System (GP5UR1DC5), Hard Disk Cabinet(GP5MS623A)

[CTO option]

Hard Disk Drive-9GB GP5-HDH9A ■ ■ ■ ■ ■ ■ 1"height/9.1GB/Ultra160/10000rpm/SCA2/80pin/Hotplug/SMART

GP5BHDH9A For MS610, Storage System (GP5UR1DC5), Hard Disk Cabinet(GP5MS623A)

[CTO option]

Hard Disk Drive-18GB GP5-HDH88 ■ ■ 1"height/18.2GB/Ultra160/7200rpm/SCA2/80pin/Hotplug/SMART

GP5BHDH88 For MS610, Storage System (GP5UR1DC5), Hard Disk Cabinet(GP5MS623A)

[CTO option] Available as of August 20th

Hard Disk Drive-9GB GP5-HDH9B ■ ■ 1"height/9.1GB/Ultra160/7200rpm/SCA2/80pin/Hotplug/SMART

GP5BHDH9B For MS610, Storage System (GP5UR1DC5), Hard Disk Cabinet(GP5MS623A)

[CTO option] Available as of August 20th

Hard Disk Drive-18GB GP5-HDH83 ■ ■ ■ ■ ■ ■ ■ 1"height/18.2GB/Ultra2wide SCSI/7200rpm/SCA2

80pin/Hotplug/SMART/ For MS380/ES280

Hard Disk Drive-9GB GP5-HDH96 ■ ■ ■ ■ ■ ■ ■ 1"height/9.1GB/Ultra2wide SCSI/7200rpm/SCA2

80pin/Hotplug/SMART/For MS380/ES280

Hard Disk Drive-18GB GP5-HD8G1 ■ ■ ■ ■ ■ ■ ■ ■ 1"height/18.2GB/Ultra2 Wide SCSI/7200rpm/68pin/Non

GP5BHD8G1 Hotplug/SMART/ For ES210, ES200 (Mounted in HDD Bay), ES280

[CTO option]

Hard Disk Drive-9GB GP5-HD9G3 ■ ■ ■ ■ ■ ■ ■ ■ 1"height/9.1GB/Ultra2 Wide SCSI/7200rpm/68pin/Non

GP5BHD9G3 Hotplug/SMART/ For ES210, ES200 (Mounted in HDD Bay), ES280

[CTO option]

Hard Disk Drive-18GB GP5-HD8G1C ■ ■ ■ ■ ■ 1"height/18.2GB/Ultra2 Wide SCSI/7200rpm/68pin/Non

GP5BHD8G1C Hotplug/SMART/ For ES210/ES200 (Mounted in 5"Bay)

[CTO option]

Hard Disk Drive-9GB GP5-HD9G3C ■ ■ ■ ■ ■ 1"height/9.1GB/Ultra2 Wide SCSI/7200rpm/68pin/Non

GP5BHD9G3C Hotplug/SMART/ For ES210/ES200 (Mounted in 5"Bay)

[CTO option]

Hard Disk Drive-20GB GP5-HD2E1 ■ ■ ■ ■ ■ EIDE,5400rpm, 20.4GB, for ES210/ES200

GP5BHD2E1

[CTO option]

Drive Cage Conversion Kit GP5BBU1 ■ ■ Standard Drive Cage conversion 1ch 1"/1.6"HDDx8 to 2ch 1"HDDx12

[CTO option]

Storage System GP5UR1DC5 ■ ■ R R R R R R R R R Hard Disk Node LVD/SE (Ultra2 Wide/Ultra Wide)for Rack (4U) 8 Hot

plug HDD Bays (up to 291.2GB: 36.4GBx8)/Ultra2 Wide/Ultra Wide

SCSI/Redundant&Hotplug FAN(Std.)/PSU(A GP5UR1PU1is standard

equipment, up to two)

<Required Components>

1. GP5-127/GP5B127-GP5MU823A/GP5S-833/GP5S-834 (HS900/MS610/MS380)

2. GP5-125/GP5B125-GP5MU823A(ES280)

3. GP5-144(146)/GP5B144(146)-GP5S-832/GP5S-835/GP5S-836 (HS900/MS610/MS380)

4. GP5U141/GP5BU141-GP5MU829A (ES280)

<Available HDD>

GP5-HDH63/GP5-HDH87/GP5-HDH9A/GP5-HDH88/GP5-HDH9B

CTO is available

30

Page 31: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

Hardware

HS900 MS10 MS380 ES280 ES210 ES200

ProductProduct ID(Overseasinc.Korea)

GP

5T9A

32R

GP

5T9A

22R

GP

5T6B

H1A

(R)

GP

5T6B

G1A

(R)

GP

5G80

4L(R

)

GP

5G80

3L(R

)

GP

5G80

2L(R

)

GP

5G80

1L(R

)

GP

5C80

3(R

)

GP

5C80

2(R

)

GP

5C80

1(R

)

GP

5T2B

C1A

GP

5T2B

51A

GP

5T2B

Y1A

GP

5T2A

Y1A

2

GP

5T2A

F1A

2

Remarks

Hard Disk Cabinet GP5MS623A P P P P P P P P P ■ ■ ■ ■ ■ Hard Disk Node LVD/SE (Ultra2 Wide/Ultra Wide)for Pedestal 8 Hot

plug HDD Bays (up to 291.2GB: 36.4GBx8)/Ultra2 Wide/Ultra Wide

SCSI/Redundant&Hotplug FAN(Std.)/PSU(A GP5UR1PU1is standard

equipment, up to two)

<Required Components>

1. GP5-127/GP5B127-GP5MU823A(MS610/MS380)

2. GP5-125/GP5B125-GP5MU823A(ES280)

3. GP5-144(146)/GP5B144(146)-GP5S-832 (MS610/MS380)

4. GP5U141/GP5BU141-GP5MU829A (ES280)

<Available HDD>

GP5-HDH63/GP5-HDH87/GP5-HDH9A/GP5-HDH88/GP5-HDH9B

CTO is available

DAT unit (DDS-4) GP5-DT401 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal DAT unit (DDS-4:20GB-40GB)/SCSI Card (GP5-127

GP5BDT401 /GP5B127 or GP5-125/GP5B125) is required (Exclude HS900)

[CTO option] Cable is included.

DAT unit (DDS-3) GP5UDT301 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal DAT unit (DDS-3:12-24GB)

GP5BDT301

[CTO option]

Tape unit (SLR5) GP5USL501 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal SLR unit (SLR-5: 4-8GB)

GP5BSL501

[CTO option]

DLT unit GP5UDL201 ■ ■ ■ ■ ■ ■ ■ ■ Internal DLT unit (DLT4000: 20GB-40GB) Two 5" bays are occupied to mount

GP5BDL201

[CTO option]

DLT unit GP5-DL351 ■ ■ ■ ■ ■ ■ ■ ■ Internal DLT unit(DLT7000: 35-70GB) Two 5"bays are required and occupied

GP5BDL351 An additional PSU is required when DLT7000 is installed in MS380.

[CTO option]

Tape unit (MLR-3) GP5-ML301 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Internal MLR unit (MLR-3: 25-50GB) SCSI Card (GP5-127/GP5B127 or GP5-125

GP5BML301 GP5B125) is required (Exclude HS900)

[CTO option]

Backup Cabinet GP5UR1BC1 ■ ■ Rackmount 3U 5" bay node for HS900 Up to four Tape units

can be mounted, GP5UDL351(two bays are occupied),GP5-ML301,

GP5-DT401, GP5UDT301,GP5USL501,GP5UDL201 are

available/Power management (RCI)/Redundant PSU (Opt.)

Redundant Power GP5UPU131 ■ ■ ■ ■ Redundant PSU (450W), For MS380

Supply Unit GP5BUPU131

[CTO option]

Redundant Power GP5UPU151 ■ ■ Redundant PSU (305W) for Backup Cabinet (GP5UR1BC1)

Supply Unit GP5BUPU151

[CTO option]

Redundant Power GP5UPU161 ■ ■ Redundant PSU (350W), For MS610

Supply Unit GP5BUPU161

[CTO option]

Redundant Power GP5UR1PU1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Redundant PSU for GP5UR1DC5/GP5MS623A (350W)

Supply Unit GP5BUR1PU1

[CTO option]

Rackmount Pattern GP5RMP ■ R R R R R R R R R R Rackmount pattern instruction

40U Rack GP5-R1RC4 ■ ■ R R R R R R R R R 19'' 40U Locker , Front door,rear door,side panel,earthquake proof

board ,blank panel is attached. Size(WxDxH)mm:600x900x2000

<Number of units required for installation>

ES280:6U/MS380,MS610:7U,HS900:7U/

GP5UR1DC5: 4U Keyboard/Monitor Shelf: 9U(for

installation 15''CRT),1U(for installation Keyboard) /Component shelf:

5U CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)

40U Rack&Rack GP5-R1RC5 ■ ■ R R R R R R R R R 19''40U Locker + connection metal fittings Front door,rear

Coupling Kit door,concatenation frame,blank panel is attached.

24U Rack GP5-R2RC1 ■ ■ R R R R R R R R R 19'' 24U Locker , Front door,rear door,side panel,earthquake proof

board, blank panel is attached. Size(WxDxH)mm:600x900x1200

<Number of units required for installation>

ES280:6U/MS380,MS610:7U,HS900:7U/

GP5UR1DC5: 4U Keyboard/Monitor Shelf: 9U(for

installation 15''CRT),1U(for installation Keyboard)/Component shelf:

5U CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)

24U Rack&Rack GP5-R2RC2 ■ ■ R R R R R R R R R 19''24U Locker + connection metal fittings Front door,rear

Coupling Kit door,concatenation frame,blank panel is attached.

Component Shelf GP5-R1TB4 ■ ■ R R R R R R R R R Shelf to fit peripheral device into 40U Rack, Table size:400(W)x500(D)

31

Page 32: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

32

Hardware

HS900 MS610 MS380 ES280 ES210 ES200

ProductProduct ID(Overseasinc.Korea)

GP

5T9A

32R

GP

5T9A

22R

GP

5T6B

H1A

(R)

GP

5T6B

G1A

(R)

GP

5G80

4L(R

)

GP

5G80

3L(R

)

GP

5G80

2L(R

)

GP

5G80

1L(R

)

GP

5C80

3(R

)

GP

5C80

2(R

)

GP

5C80

1(R

)

GP

5T2B

C1A

GP

5T2B

51A

GP

5T2B

Y1A

GP

5T2A

Y1A

2

GP

5T2A

F1A

2

Remarks

Keyboard/Monitor Shelf Kit GP5-R1TB5 ■ ■ R R R R R R R R R Used to store display unit (CRT), a keyboard (KB), and a mouse on a rack.

Keyboard/Monitor GP5-SB101 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Switch enables sharing of a set of CRT,keyboard,and mouse by two

Enhanced Switch or more servers (up to four servers).

Keyboard/Monitor GP5-SB102 ■ ■ R R R R R R R R R Switch enables sharing of a set of CRT,keyboard,and mouse by two

Enhanced Switch or more servers (up to eight servers). Shared up to 64 servers in

cascade connection.* AC adapter is required for cascade connection

(Procured locally)

Keyboard/Monitor Cable GP5-418 ■ ■ R R R R R R R R R For connection with switch (For connection GP5-SB102) (5.0m)

Keyboard/Monitor Cable GP5-414 ■ ■ R R R R R R R R R For cascade connection between GP5-SB102 (1.8m)

Keyboard/Monitor Extension Cables GP5-411 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ CRT/KB cable for connection Server with SB-101,

CRT cablex1,KB/Mouse cablex1 is attached

Enhanced Keyboard GP5-R1KB2 ■ ■ R R R R R R R R R 87Key keyboard for Rackmountable type

Flat Display GP5UR1DP1 ■ ■ R R R R R R R R R Rackmountable LCD display with Keyboard, 2U height

Power Distribution Unit GP5UPDU1 ■ ■ R R R R R R R R R Power Distribution Unit (8sockets), Power cables (0.4m)x8 are included

SCSI Card GP5-123 ■ ■ ■ ■ ■ ■ ■ ■ Ultrawide (HVD:High Voltage Differential)1ch//SMART HDD is not

supported/ Up to 40MB/s of syncronous transfer support/For

connection with Disk Array devices -68-pin connector for external

SCSI device (Ultra Wide)x1 -68-pin connector for internal SCSI device

(Ultra Wide )x1-50-pin connector for internal SCSI device (Narrow)x1

* SCSI cable is required.

SCSI Card GP5-125 ■ ■ ■ Ultra Wide(SE)/1ch/SMART HDD/Transfer speed: up to 40MB/s-68-

GP5B125 pin connector for external SCSI device (Ultra Wide)x1 -68-pin

[CTO option] connector for internal SCSI device (Ultra Wide SE)x1-50-pin

connector for internal SCSI device (Narrow)x1(Either external or

internal connector is used)*SCSI cable is required

SCSI Card GP5-126 ■ ■ Ultra2wide(LVD)/1ch/SMART HDD/Transfer speed: up to 80MB/s-68-

GP5B126 pin connector for external SCSI device (Ultra2 Wide)x1-68-pin

[CTO option] connector for internal SCSI device (Ultra2 Wide)x1 -68-pin connector

for internal SCSI device (Ultra Wide SE)x1-50-pin connector for

internal SCSI device (Narrow)x1(Internal Ultra2 Wide and Narrow

SCSI can be used in teamserver) *SCSI cable is required

SCSI Card GP5-127 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ultra2wide(LVD)/1ch/SMART HDD/Up to 80MB/s of syncronous

GP5B127 transfer-68-pin connector for external device (Ultra2 Wide)x1-68

[CTO option] pin connector for internal device (Ultra2 Wide)x1(Either external or

internal connector is used)

RAID Card GP5U141 ■ ■ ■ RAID Card, Ultra Wide SCSI(SE)/2ch/16MB cache/RAID level 0,1,5,6

GP5BU141 are supported For internal/external array configuration *SCSI

[CTO option] cable(for array configuration use) is required.

RAID Card GP5-143 ■ ■ ■ ■ ■ ■ ■ ■ RAID Card, Ultra2 wide(LVD)/1ch/8MB cache/RAID level 0,1,5,6 are

GP5B143 supported/For internal array configuration/One GP5-143/GP5B143

[CTO option] can be used in one server*SCSI cable(for array configuration use) is

required

RAID Card GP5-144 ■ ■ ■ ■ ■ ■ ■ ■ RAID Card, Ultra2wide (LVD)/3ch/32MB cache/Battery Backup/RAID

GP5B144 level 0,1,5,6 are supported For internal/external array configuration

[CTO option] *SCSI cable(for array configuration use) is required

RAID Card GP5-146 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ RAID Card, Ultra2wide (LVD)/2ch/16MB cache/Battery Backup/RAID

GP5B146 level 0,1,5,6 are supported For internal/external array configuration

[CTO option] *SCSI cable(for array configuration use) is required

SCSI Cable GP5S-832 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ For connection: -GP5-144/GP5B144 or GP5-146/GP5B146 to

GP5UR1DC5/GP5MS623A-Backup Cabinet (GP5UR1BC1) to

HS900 (3m)

SCSI Cable GP5S-833 ■ ■ ■ ■ ■ ■ ■ ■ For connection GP5-127/GP5B127 to GP5UR1DC5 (5m), Only for

Rackmount

SCSI Cable GP5S-834 ■ ■ ■ ■ ■ ■ ■ ■ For connection GP5-127/GP5B127 to GP5UR1DC5(10m), Only for

Rackmount

SCSI Cable GP5S-835 ■ ■ ■ ■ ■ ■ ■ ■ For connection GP5-144/GP5B144 or GP5-146/GP5B146 to

GP5UR1DC5(5m), Only for Rackmount

SCSI Cable GP5S-836 ■ ■ ■ ■ ■ ■ ■ ■ For connection GP5-144/GP5B144 or GP5-146/GP5B146 to

GP5UR1DC5 (10m), Only for Rackmount

SCSI Cable GP5-840 ■ ■ Internal narrow SCSI cable(68pin-50pin) for 5'' Bay of ES200/Connect

GP5B840 with GP5-127/GP5B127

[CTO option]

SCSI Cable GP5-841 ■ ■ Internal narrow SCSI cable(50pin-50pin) for 5'' Bay of ES200/Connect

GP5B841 with GP5-126/GP5B126

[CTO option]

Page 33: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

33

Hardware

HS900 MS610 MS380 ES280 ES210 ES200

ProductProduct ID(Overseasinc.Korea)

GP

5T9A

32R

GP

5T9A

22R

GP

5T6B

H1A

(R)

GP

5T6B

G1A

(R)

GP

5G80

4L(R

)

GP

5G80

3L(R

)

GP

5G80

2L(R

)

GP

5G80

1L(R

)

GP

5C80

3(R

)

GP

5C80

2(R

)

GP

5C80

1(R

)

GP

5T2B

C1A

GP

5T2B

51A

GP

5T2B

Y1A

GP

5T2A

Y1A

2

GP

5T2A

F1A

2

Remarks

SCSI Cable GP5-843 ■ ■ ■ ■ ■ Internal Wide SCSI cable(68pin-68pin) for ES210/ES200

GP5B843 ES210: Connect GP5-127/GP5B127/GP5-143/GP5B143 with Hard Disk Drive

[CTO option] ES200: Connect GP5-126/GP5B126/GP5-143/GP5B143 with Hard Disk Drive

SCSI Cable GP5MU823A ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5-125 or GP5-

127/GP5B127 to GP5MS623A,GP5UR1DC5 (3.0m)

SCSI Cable GP5MU829A ■ ■ ■ ■ ■ ■ ■ SCSI-3(68pin)-SCSI-4(68pin), For connecting GP5U141to

GP5MS623A,GP5UR1DC5 (2.0m)

SCSI Cable GP5U831 ■ ■ ■ Connenction internal Hard Disk Drive in ES280

GP5B831

[CTO option]

SCSI Cable GP5U832 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI Cable half68pin-Full50pin (1.0m)/For connect external SCSI

device

SCSI Cable GP5U833 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI Cable half68pin-half50pin (1.0m)/For connect external SCSI

device

SCSI Cable GP5U834 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ SCSI Cable half50pin-full50pin (1.0m)/For connect external SCSI

device

Fibre Channel Cable GP5-311 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Fibre Channel Cable (2m) : For Giga LAN Card (GP5-183)

Fibre Channel Cable GP5-312 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Fibre Channel Cable (5m) : For Giga LAN Card (GP5-183)

Fibre Channel Cable GP5-313 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Fibre Channel Cable (15m) : For Giga LAN Card (GP5-183)

LAN Card (1000Base-SX) GP5-183 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 1000BASE-SX/PCI64bit/driver is included Fibre Channel cable is

GP5B183 required : GP5-311/2m, GP5-312/5m, GP5-313/15m

[CTO option]

LAN Card GP5-185 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 100BASE-TX/10BASE-T/PCI64bit/driver is includedAFT(Adapter Fault

GP5B185 Tolerance)/ALB(Adaptive Load Balance)Twisted pair cable (category

[CTO option] 5:100BASE-TX/category 3:10BASE-T) is required

LAN Card GP5-186 ■ ■ Dual Port/100BASE-TX/10BASE-T/PCI64bit/driver is includedTwisted

GP5B186 pair cable (category 5:100BASE-TX/category 3:10BASE-T) is required

[CTO option]

LAN Card GP5-187 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ IP security transaction NIC (3DES standard), 100BASE-TX/10BASE-T/

GP5B187 PCI64bit/driver is includedTwisted pair cable (category 5:100BASE-TX/

[CTO option] category 3:10BASE-T) is required

Server Monitor Module GP5USM103 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Server Monitor Module has its own CPU,LAN,and power supply (AC

GP5BUSM103 adapter: option-procured locally)/External Interface:10BASE-T

[CTO option] RJ45/RS232C D-sub 9pin/AC adapter:16V(DC) * Modem-only

operation is impossible.

Page 34: System Configuration Guide (V.2) - Fujitsu Global · Interface connect connect device x 2 device x 2 and device*2 device*3 Wide device Cable ... Configuration When Drive RAID Card

Specifications are subject to change without notice. For the latest detailed information, contact your local representative. All brand names and product names are trademarks and registered trademarks of their respective holders.C2000 Fujitsu Limited. All rights reserved. Printed in Japan.

Eleventh Edition June 2000

FUJITSU LIMITEDGlobal MarketingBusiness Development & Marketing DivisionComputer System GroupPhone: +81-44-754-3210 Fax: +81-44-754-3321URL http://www.fujitsu.co.jp/en/servers/primergy/

BK0065-11NS