ARMOR MINIATURE CIRCUIT BREAKER (MCB)
ARMOR ISOLATOR
ARMOR RESIDUAL CURRENT CIRCUIT BREAKER
ARMOR MINI CHANGEOVER SWITCH
NUEVO RE-WIREABLE SWITCH FUSE (SINGLE BREAK)
NUEVO CHANGEOVER SWITCH (OFF LOAD)
NUEVO RE-WIREABLEKIT KAT-KAT FUSE
NUEVO SHEET METAL CUT-OUT
NUEVO HRC FUSE HOLDER
NUEVO BUSBAR CHAMBER
NUEVO REVERSE FORWARDING SWITCH
SCION SPN DD DB's
SCION TPN DD DB's
SCION VERTICAL PHASE SELECTOR TPN DD DB's
SCION HORIZONTAL PHASE SELECTOR TPN DD DB's
INSPIRO SPN DB's
INSPIRO TPN DB's
MAGNA SPN DD DB’s (DL)
MAGNA TPN DD DB’s (DL)
MAGNA PHASE SELECTOR DB’s
MAGNA PLUG & SOCKET ENCLOSURE
MAGNA PLUG & SOCKET
MAGNA CAM OPERATED ROTARY SWITCH
NEX SPN SD DB’s
NEX SPN DD DB’s
NEX TPN DD DB’s
MODULAR METAL GANG BOX
MAGNA SPN SD DB’s (CH)
MAGNA SPN DD DB’s (CH)
MAGNA TPN DD DB’s (CH)
MAGNA PHASE SELECTOR DD DB’s (CH)
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
----------------------------
CONTENTS PAGE NO.
Technical Specification
1
Suitable for Reverse Feed Connections (Line and Load) & Rated Breaking Capacity 10 kA.
Silver Graphite contact tips assure Antiweld Property.
Snap-On-Back mounting for 35mm x 15mm symmetrical DIN rail.
Terminals suitable for Cable + Bus bar temination.
Do not tend to bulge or wrap, when high cross sectional cables are terminated.
F
E
D
A
CB
G
TYPE
SP
SPN
DP
TP
TPN
FP
VOLTS
240/415V
240/415V
240/415V
240/415V
240/415V
240/415V
A
50
50
50
50
50
50
B
82
82
82
82
82
82
C
45.5
45.5
45.5
45.5
45.5
45.5
D
44.4
44.4
44.4
44.4
44.4
44.4
E
66.3
66.3
66.3
66.3
66.3
66.3
F
71.9
71.9
71.9
71.9
71.9
71.9
G
17.50
35.00
35.00
52.50
70.00
70.00
RATING
6A-63A
6A-63A
6A-63A
6A-63A
6A-63A
6A-63A
KSG400201/02/03/04/05/06/300/401/402
KSG400601/02/03/04/05/06/700/801/802
KSG401001/02/03/04/05/06/1100/1201/1202
KSG401401/02/03/04/05/06/1500/1601/1602
KSG401801/02/03/04/05/06/1900/2001/2002
KSG402201/02/03/04/05/06/2300/2401/2402
MINIATURE CIRCUIT BREAKER (MCB)
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
MINIATURE C IRCUIT BREAKER
CAT No.
ISOLATOR
Silver Graphite contact tips for Long Last.
Knob Operatable.
Suitable for all switching and Isolation.
An isolator in a manual operated device used for disconnecting the supply.
Contact Position Indication.
TYPE
DP
TP
FP
VOLTS
240/415V
240/415V
240/415V
A
50
50
50
B
82
82
82
C
45.5
45.5
45.5
D
44.4
44.4
44.4
E
66.3
66.3
66.3
F
71.9
71.9
71.9
G
35.00
52.50
70.00
RATING
25A-100A
25A-100A
25A-100A
CAT. No.
KSG402500/2600/2700/2800/2900/3000
KSG403100/3200/3300/3400/3500/3600
KSG403700/3800/3900/4000/4100/4200
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
2
F
E
D
A
CB
G
40 A
I S O L A T O R
Technical Specification
3
TYPE
DP
DP
DP
FP
FP
FP
VOLTS
240/415V
240/415V
240/415V
240/415V
240/415V
240/415V
A
50
50
50
50
50
50
B
102
102
102
102
102
102
C
45
45
45
45
45
45
D
84.4
84.4
84.4
84.4
84.4
84.4
E
35.7
35.7
35.7
35.7
35.7
35.7
F
81
81
81
81
81
81
G
35.40
35.40
35.40
71.00
71.00
71.00
RATING
16A-100A
16A-100A
16A-100A
16A-100A
16A-100A
16A-100A
KSG404901/02/5000/5100/5200/5300
KSG405401A/402A/5501A/5601A/5701A/5801A
KSG405401B/02B/5501B/5601B/5701B/5801B
KSG405901/02/6000/6100/6200/6300
KSG406401A/02A/6501A/6601A/6701A/6801A
KSG406401B/02B/6501B/6601B/6701B/6801B
RESIDUAL CURRENT CIRCUIT BREAKER
mA
30mA
100mA
300mA
30mA
100mA
300mA
H
66.80
66.80
66.80
66.80
66.80
66.80
I
77.00
77.00
77.00
77.00
77.00
77.00
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
RESIDUAL CURRENT CIRCUIT BREAKER
I
H
A
CB D E
F
G
In: 40 AI n:0.10AUn:415~50 HzIm:500 A
10000 ~
RCCB
Technical Specification
Model
Residual Current Characteristics
Rated Making and Breaking Capacity
Dielectric Strength
Rated Current (A)
Rated Voltage
Rated Frequency
Rated Residual Operating Current I n(A)
Rated Residual Non Operating Current I n
Tripping Duration
Residual Tripping Current Range
Electro-Mechanical Endurance
Connection Capacity
Installation
Range
No. of Pole
CAT No.
4
No. of Amp.
25/40/63 Amp.
25/40/63 Amp.
CAT. No.
KSG404300/4400/4500
KSG404600/4700/4800
A
45.5
45.5
B
83.5
83.5
C
45.5
45.5
MINI CHANGEOVER SWITCH
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
MINI CHANGEOVER SWITCH
OU
T
4 108
1 5
2
139
12 14 16
240/415V
40 A
F
E
D
A
CB
G
TYPE
DP
FP
D
45.5
45.5
E
50.0
50.0
F
72.0
72.0
G
35.5
71.0
Technical Specification
TYPE
SPN & DP
SPN & DP
TPN
TPN
TPN
TPN
TPN
FP
VOLTS
240
240
415
415
415
415
415
415
A
144
220
222
261
347
447
495
264
B
94
135
176
208
293
330
381
261
C
55
72
72
77
102
157
157
85
D
45
85
87
121
228
195
246
184
E
113
170
174
205
283
374
425
212
F
135
168
213
247
358
390
440
292
G
69
113
130
133
204
150
170
145
RATING
16A
32A
16A
32A
63A
100A
200A
32A
KSG2051/53
KSG2052/54
KSG2055
KSG2056
KSG2057
KSG2058
KSG2059
KSG2060
H
65
315
320
370
485
570
610
370
RE-WIREABLE SWITCH FUSE UNIT K'OUT
TOP/BOTTOM
Ø26, 1 / 1 Nos.
Ø26, 1 / 1 Nos.
Ø26, 3 / 3 Nos.
Ø26, 3 / 3 Nos.
Ø37, 3 / 3 Nos.
Ø37, 3 / 3 Nos.
Ø37, 3 / 3 Nos.
Ø26, 4 / 4 Nos.
THICKNESS
0.9 MM
1.0 MM
1.0 MM
1.0 MM
1.2 MM
1.5 MM
1.5 MM
1.0 MM
5
B
A E
D
C
H
Technical Specification
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
F G
REWIRABLE SWITCH FUSE UNIT
CAT. No.
F
BG
C
H
D
A E
6
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
CHANGEOVER SWITCH FUSE UNIT
A
359
359
496
496
B
332
332
429
429
C
180
180
235
235
D
264
264
356
356
E
290
290
416
416
F
420
420
520
520
G
260
260
285
285
H
271
271
435
435
KNIFE TYPE
ø37, 4 / 4 Nos.
ø37, 4 / 4 Nos.
ø38, 4 / 4 Nos.
ø38, 4 / 4 Nos.
RATING
63A
100A
200A
320A
THICKNESS
1.5 MM
1.5 MM
1.5 MM
1.5 MM
TYPE
DP
TP
FP
FP
DP
FP
DP
FP
VOLTS
240
415
415
415
240
415
240
415
A
220
174
208
174
311
315
397
394
B
134
222
261
222
198
345
248
430
C
81
81
81
81
134
134
164
164
D
85
184
211
184
128
272
182
360
E
171
134
155
134
146
245
335
335
F
174
273
305
273
258
405
330
330
G
63
48
75
48
73
75
65
65
RATING
32A
32A
32A
16A
63A
63A
100A
100A
CAT. No.
KSG2061
KSG2064
KSG2066
KSG2065
KSG2062
KSG2067
KSG2063
KSG2068
H
113
96
125
96
166
166
212
212
CHANGEOVER SWITCH (OFF LOAD)
ø26, 1 / 1 Nos.
ø26, 3 / 3 Nos.
ø26, 4 / 4 Nos.
ø26, 4 / 4 Nos.
ø37, 2 / 2 Nos.
ø37, 4 / 4 Nos.
ø37, 2 / 2 Nos.
ø37, 4 / 4 Nos.
K'OUT
TOP/BOTTOMTHICKNESS
1 MM
1 MM
1 MM
1 MM
1.5 MM
1.5 MM
1.5 MM
1.5 MM
CAT NO.
KSG2069
KSG2070
KSG2071
KSG2072
7
J
C
B G
H
FI A E
VOLTS
63A/415V
100A/415V
200A/415V
200A/415V
A
104
163
188
188
B
42
68
63
63
C
43
64
68
68
D
67
110
117
117
E
27
57
67
67
F
104
160
175
175
G
24
64
49
49
H
47
86
20
20
KIT KAT TURBO SERIES
I
246
J
18
26
31
31
CAT No.
KSG2031
KSG2032
KSG2033
KSG2034
VOLTS
16/240V
16/415V
32/415V H
63/415V H
100/415V
200/415V
300/415V
500/415V
A
63
74
110
133
169
193
208
208
B
29
30
37.50
49
61
63
90
90
C
38
34
43
59
65
67
90
90
D
45
50
84
98
117
117
141
141
E
32.50
37
44
45.50
60
64
59
59
F
62
74
108
134
160
183
198
198
G
14
18
32
43
56
49
47
47
H
31
37
57
77
91
92
86
86
REWIREABLE KIT KAT FUSE UNIT
J
9
10.50
10.50
17
22
22
43
43
CAT NO.
KSG2023
KSG2024
KSG2025
KSG2026
KSG2027
KSG2028
KSG2029
KSG2030
I
285
285
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Technical Specification
REWIRABLE KIT KAT FUSE UNIT
8
B
D
A
FC
E
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
SHEET METAL CUT OUT
No. of Amp.
16 Amp.
32 Amp.
63 Amp.
100 Amp.
A
88.5
123.50
204
230
B
48.5
65
83
100
C
58
63
114
122
D
87
44
44
63
E
78
100
160
186
F
73
89
97
117
SHEET METAL CUT-OUT (ENCLOSURE) K'OUT
TOP/BOTTOM
ø12.5 1 / 1
ø20 1 / 1
ø26 1 / 1
ø26 1 / 1
CAT No.
KSG2035
KSG2036
KSG2037
KSG2038
THICKNESS
0.9 MM
0.9 MM
1.2 MM
1.2 MM
Surface Mounting
Light Grey Texture Finish
CRCA Sheet Steel
4 kA
2.5 kV
240 - 415V AC
IP23
690V AC
50 Hz
-5º C to 40º C
16, 32, 63 & 100 Amp.
9
Technical Specification
No. of Amp.
20 Amp.
32 Amp.
63 Amp.
125 Amp.
A
67.50
97
103.50
128.50
B
27
32.50
36.70
47.50
C
31
38
43
58.50
D
42
57
64
85
E
14
13.50
14
23
F
79
103
109
136
HRC FUSE HOLDER K'OUT
TOP/BOTTOM
ø9 1 X 1
ø20 1 X 1
ø20 1 X 1
ø20 1 X 1
G
29
44
47.50
68
H
15
19
21.50
26
I
6.50
8.70
10.50
15
CAT No.
KSG2073
KSG2074
KSG2075
KSG2076
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
H R C F U S E H O L D E R
H
G
I
C
B
E FA
D
E
B C
A F
D
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Surface Mounting
Light Grey Texture Finish
CRCA Sheet Steel
10kA for 1 second
2.5 kV
240 - 415V AC
690V AC
50 Hz
-5º C to 40º C
IP40
32, 63, 100 & 200 Amp. (4 Way)
B U S B A R C H A M B E R
No. of Amp.
32 Amp.
63 Amp.
100 Amp.
200 Amp.
A
203
224
318
384
B
256
310
379
460
C
108
117
138
138
D
103
114
135
133
E
200
244
305
378
F
136
158
250
316
BUSBAR CHAMBER K'OUT
TOP/BOTTOM
ø26, 4 / 4
ø30, 4 / 4
ø30, 4 / 4
ø30, 4 / 4
K'OUT
LH/RH SIDE
ø26, 4 / 4
ø26, 4 / 4
ø30, 4 / 4
ø30, 4 / 4
THICKNESS
1 MM
1 MM
1 MM
1 MM
CAT No.
KSG2046
KSG2047
KSG2048
KSG2049
10
Technical Specification
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
PPI System - push and pull interlocking system.
99.99% ETP (Electrolytic Tough Pitch) copper used in static and moving parts.
Manufacturing of Bakelite block through CNC moulding.
Alignment of mechanism are fixed for long durability.
Metal handle for more strength.
Aesthetic new housing made from high quality steel.
Amp.
16 Amp.
25 Amp.
32 Amp.
CAT. No.
KSG2039
KSG2040
KSG2041
A
88
118
118
B
73
93.5
93.5
C
65
79
79
2 Nos.
2 Nos.
2 Nos.
REVERSE FORWARDING SWITCH ø 20, K'OUT
BOTTOMD
53.5
76
76
E
60.5
95.5
95.5
F
121
153.5
153.5
A
REVERSE FORWARDING SWITCH
F
C
B
D
E
12
No. of Ways
4
6
8
12
16
CAT. No.
KDB3001
KDB3002
KDB3003
KDB3004
KDB3005
A
173
173
248
318
390
B
96
96
170
244
315
C
189
189
261
334
406
3 / 3 Nos.
3 / 3 Nos.
4 / 4 Nos.
6 / 6 Nos.
6 / 6 Nos.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
0.9 MM
0.9 MM
0.9 MM
0.9 MM
0.9 MM
SPN DISTRIBUTION BOARD ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDETHICKNESS
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
D I S T R I B U T I O N B O A R D
Type of Installation
Colour / Finish
Distribution Technique
Material
Busbar Rating
Dielectric Strength
Rated Short Time with Stand (Icw)
Rated Conditional Short Circuit (Ics)
Voltage Rating
Neutral Bar Terminal Capacity
Earthing Bar Terminal Capacity
Degree of Protection (IP)
Insulation Voltage (Ui)
Frequency
Ambient Temperature
Reference Standard
Incoming:
Outgoing
Range
Type
Surface & Flush Mounting
Light Grey Texture Finish
Insulated Busbar
CRCA Sheet Steel
100A
2.5 kV
5 kA for 0.1 second
10 kA
240V AC 1 Phase
16 mm2
16 mm2
IP43
690V AC
50 Hz
-5º C to 40º C
IS 8623; IS 13032; IEC 61439-3
Two pole MCBs / RCCB / Isolator
SP MCBs
4, 6, 8, 12 & 16 Ways
Double Door
Technical Specification
24
0
C
84.5
BA
14
1
22
2
81
13
380
446
48
1
C101
No. of Ways
4 (4+12)
6 (4+18)
4 (8+12)
6 (8+18)
8 (8+24)
CAT. No.
KDB3006
KDB3007
KDB3008
KDB3009
KDB3010
A
251
320
320
396
396
B
180
242
242
330
330
C
260
334
334
405
405
4 / 4 Nos.
6 / 6 Nos.
6 / 6 Nos.
8 / 8 Nos.
8 / 8 Nos.
2 / 2 No.
2 / 2 No.
2 / 2 No.
2 / 2 No.
2 / 2 No.
ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
0.9 MM
0.9 MM
0.9 MM
0.9 MM
0.9 MM
THICKNESS
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
TPN DISTRIBUTION BOARD
D I S T R I B U T I O N B O A R D
Technical Specification
107
BA
14
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
No. of Ways
4
6
8
CAT. No.
KDB3011/12/13
KDB3014/15/16
KBD3017/18/19
A
320
320
398
B
233
233
316
C
334
334
407
6 / 6 Nos.
6 / 6 Nos.
8 / 8 Nos.
2 / 2 No.
2 / 2 No.
2 / 2 No.
VERTICAL PHASE SELECTOR TPN DB ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
1 MM
1MM
1 MM
ø 26, K'OUT
LH/RH SIDE
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
D I S T R I B U T I O N B O A R D
Technical Specification
138
52
0
59
7
63
5
C
BA
136
15
No. of Ways
4 (4+12)
CAT. No.
KDB3020/21/22
A
372
B
271
C
391 3 / 3 Nos. 1 / 1 No.
HORIZONTAL PHASE SELECTOR TPN DB ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
1 MM
THICKNESS
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
Technical Specification
Surface & Flush Mounting
Light Grey Texture Finish
Insulated Busbar
CRCA Sheet Steel
100A
2.5 kV
5 kA for 0.1 second
10 kA
240-415V AC, 3 Phase / 4 Wire
16 mm2
16 mm2
IP43
690V AC
50 Hz
-5º C to 40º C
IS 8623 : IS 13032, IEC 61439-3
Four Pole MCBs/RCCB/Isolator
SP MCBs
4 Way (4+12)
(with or without Rotary Wiring)
Double Door
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
D I S T R I B U T I O N B O A R D
28
5
36
1
388
C
14
8
BA
141
16
14
2
21
5
24
0
C
88
BA
76
No. of Ways
4
6
8
12
16
CAT. No.
KDB3211
KDB3212
KDB3213
KDB3214
KDB3215
A
162
201
224
307
377
B
109
145
142
253
322
C
185
220
255
326
399
2 / 2 Nos.
3 / 3 Nos.
4 / 4 Nos.
6 / 6 Nos.
8 / 8 Nos.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
SPN DISTRIBUTION BOARD ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
0.9 MM
0.9 MM
0.9 MM
0.9 MM
0.9 MM
ø 26, K'OUT
LH/RH SIDE
Type of Installation
Colour / Finish
Distribution Technique
Material
Busbar Rating
Dielectric Strength
Rated Short Time with Stand (Icw)
Rated Conditional Short Circuit Current (Ics)
Voltage Rating
Neutral Bar Terminal Capacity
Earthing Bar Terminal Capacity
Index of Protection (IP)
Insulation Voltage (Ui)
Frequency
Ambient Temperature
Reference Standard
Incoming:
Outgoing
Range
Available in
Surface & Flush Mounting
Ivory Texture Finish
Insulated Busbar
Base Box made by CRCA Sheet Steel /
Cover made by Polycarbonate Material
100A
2.5 kV
5 kA for 0.1 second
10 kA
240V AC, 1 Phase
16 mm2
16 mm2
IP43
690V AC
50 Hz
-5º C to 40º C
IS 8623; IS 13032; IEC 61439-3
Two Pole MCBs / RCCB / Isolator
SP MCBs
4, 6, 8, 12 & 16 Ways
Metal & Plastic Base
Technical Specification
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
D I S T R I B U T I O N B OA R D
17
DESCRIPTION
No. of Ways
4
CAT. No.
KDB3216
A
223
B
162
C
248 4 / 4 Nos. 2 / 2 No.
ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
1.2 MM
THICKNESS
Technical Specification
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
D I S T R I B U T I O N B OA R D
TPN DISTRIBUTION BOARD
322
390
102
41
0
C
112
BA
18
79
A B
96
146
222
241
C
No. of Ways
4
6
8
12
16
CAT. No.
KDB3310
KDB3311
KDB3312
KDB3313
KDB3314
C
209
245
281
353
425
A
175
211
247
319
391
B
125
151
187
269
341
SPN DD DISTRIBUTION BOARD (DL) ø 26+32, K'OUT
TOP/BOTTOM
3 / 3 Nos.
3 / 3 Nos.
4 / 4 Nos.
6 / 6 Nos.
6 / 6 Nos.
1 MM
1 MM
1 MM
1 MM
1 MM
THICKNESS
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
ø 32, K'OUT
LH/RH SIDE
Technical Specification
No. of Ways
4
6
8
12
CAT. No.
KDB3315
KDB3316
KDB3317
KDB3318
A
261
320
395
534
B
196
254
330
468
C
285
360
429
568
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
TPN DD DB (DL) ø 26+32, K'OUT
TOP/BOTTOM
ø 32, K'OUT
LH/RH SIDE
4 / 4 Nos.
6 / 6 Nos.
6 / 6 Nos.
8 / 8 Nos.
1 MM
1 MM
1 MM
1 MM
THICKNESS
OF BASE
THICKNESS
OF COVER
1.2 MM
1.2 MM
1.2 MM
1.2 MM
19
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Type of Installation
Colour / Finish
Distribution Technique
Material
Busbar Rating
Dielectric Strength
Rated Short Time with Stand (Icw)
Rated conditional short circuit current (Ics)
Voltage Rating
Neutral Bar Terminal Capacity
Earthing Bar Terminal Capacity
Degree of Protection (IP)
Insulation Voltage (Ui)
Frequency
Ambient Temperature
Reference Standard
Incoming:
Outgoing
Range
Type
107
BA
345
400
94
419
C
20
C D
90
96
EF
A
B
No. of Ways
25 / 32A
40 / 63A
CAT. No.
KDB3332/34
KDB3335/36
A
198
198
B
300
300
C
139
139
5 / 5 Nos.
5 / 5 Nos.
1/1 Nos.
1/1 Nos.
PHASE SELECTOR DB ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDED
190
190
E
250
250
F
305
305
THICKNESS
1 MM
1 MM
Technical Specification
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
21
16
9
C
BA
15
7
59
98
63
CAT. No.
KDB3337
A
123
B
78
C
138 1 / 1 Nos. 1 / 1 No.
PLUG & SOCKET ENCLOSURE (DL) ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Technical Specification
P L U G & S O C K E T E N C LO S U R E
Technical Specification
Amp.
20 Amp. (Plugs)
20 Amp. (Sockets)
CAT. No.
KDB3343
KDB3346
A
87
39
B
46
68.5
C
43
45
PLUG & SOCKET
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
P L U G & S O C K E T
B
A
C
Made of aluminium which provide highly heat absorbing capacity
as well as durability features.
Ease use.
Rust proof.
22
ABC
23
Amp.
25 Amp.
32 Amp.
40 Amp.
63 Amp.
CAT. No.
KDB3349
KDB3350
KDB3351
KDB3352
A
64.5
64.5
87.5
87.5
B
64.5
64.5
87.5
87.5
C
66.5
66.5
87.5
87.5
CAM OPERATED ROTARY SWITCH
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Technical Specification
C A M O P E R AT E D R OTA R Y S W I TC H
D
48
48
68.5
68.5
E
48
48
68.5
68.5
F
100
100
125
125
OFF
13A
B
C
E
D
F
No. of Ways
4
6
8
10
12
16
CAT. No.
KDB3083
KDB3084
KDB3085
KDB3086
KDB3087
KDB3088
A
121
187
224
224
262
338
B
68
134
170
170
207
284
C
131
195
235
236
274
352
2 / 2 Nos.
4 / 4 Nos.
5 / 5 Nos.
5 / 5 Nos.
6 / 6 Nos.
8 / 8 Nos.
SPN SINGLE DOOR DB
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper busbar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Distribution Boards
Technical Specification
ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
1 / 1 Nos.
1 / 1 Nos.
1 / 1 Nos.
1 / 1 Nos
1 / 1 Nos.
1 / 1 Nos.
C
19
5 10
1
18
5
60
62
B
A
24
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper busbar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Distribution Boards
Technical Specification
C
10
1
18
6
208
84
BA
81
No. of Ways
4
6
8
10
12
16
CAT. No.
KDB3089
KDB3090
KDB3091
KDB3092
KDB3093
KDB3094
A
137
166
205
241
281
356
B
90
119
158
195
234
310
C
159
191
227
267
302
377
2/2 Nos.
3/3 Nos.
4/4 Nos.
5/5 Nos.
6/6 Nos.
8/8 Nos.
SPN DOUBLE DOOR DB
1/1 Nos.
1/1 Nos.
1/1 Nos.
1/1 Nos.
1/1 Nos.
1/1 Nos.
ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
25
26
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper busbar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Distribution Boards
No. of Ways
4
6
8
12
CAT. No.
KDB3098
KDB3099
KDB3100
KDB3103
A
261
328
406
556
B
187
254
330
480
C
299
362
436
578
2 / 2 Nos.
2 / 2 Nos.
2 / 2 Nos.
2 / 2 Nos.
5 / 5 No.
7 / 7 No.
7 / 7 No.
9 / 9 No.
ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
TPN DOUBLE DOOR DB
C
31
7
38
4
41
9
98
BA
96
Technical Specification
Type of Installation
Colour / Finish
Distribution Technique
Material
Busbar Rating
Dielectric Strength
Rated Short Time withstand (Icw)
Rated Conditional Short Circuit Current (Ics)
Voltage Rating
Neutral Bar Terminal Capacity
Earthing Bar Terminal Capacity
Degree of Protection (IP)
Insulation Voltage (Ui)
Frequency
Ambient Temperature
Reference Standard
Incoming:
Outgoing
Range
Type
MODULAR METAL GANG BOX
27A
BC
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
MODULE
2
3
4
6
8 (H)
8 (V)
12
16
18
CAT. No.
V5001
V5002
V5003
V5004
V5005
V5006
V5007
V5008
V5009
METAL GANG BOX ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDEA
73 MM
73 MM
73 MM
73 MM
77 MM
131 MM
130 MM
144 MM
200 MM
2 / 2 Nos.
2 / 2 Nos.
3 / 3 Nos.
5 / 5 Nos.
5 / 5 Nos.
3 / 3 Nos.
5 / 5 Nos.
5 / 5 Nos.
5 / 5 Nos.
2 / 2 Nos.
2 / 2 Nos.
2 / 2 Nos.
2 / 2 Nos.
2 / 2 Nos.
3 / 3 Nos.
3 / 3 Nos.
3 / 3 Nos.
5 / 5 Nos.
B
75 MM
105 MM
139 MM
210 MM
230 MM
135 MM
209 MM
231 MM
212 MM
C
52 MM
52 MM
52 MM
52 MM
54 MM
60 MM
60 MM
60 MM
60 MM
Technical Specification
Brass earth.
GPSP Sheet for long lasting.
Ample space for wiring.
Cap an hinges thread to prevent cement / dust at time of constructions.
28
No. of Ways
1/2
3/4
6
8
12
16
KDB3301/02
KDB3303/04
KDB3306
KDB3307
KDB3308
KDB3309
A
76
96
154
190
261
333
B
46
66
124
160
231
303
C
83
103
161
197
268
340
1 / 1 Nos.
1 / 1 Nos.
2 / 2 Nos.
3 / 3 Nos.
4 / 4 Nos.
5 / 5 Nos.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
SPN SD DISTRIBUTION BOARD (CH) ø 26, K'OUT
TOP/BOTTOM
ø 26, K'OUT
LH/RH SIDE
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
Surface & Flush Mounting
Light Grey Texture Finish
Insulated Busbar
CRCA Sheet Steel
100A
2.5 kV
5 kA for 0.1 second
10 kA
240V AC, 1 Phase
16 mm2
16 mm2
IP40
690V AC
50 Hz
-5º C to 40º C
IS:8623, IS:13032, IEC:61439-3
Two Pole MCBs/RCCB/Isolator
SP MCBs
4 Way to 16 Way
Single Door
Technical Specification
C
CAT. No.
29
Technical Specification
No. of Ways
4
6
8
12
16
CAT. No.
KDB3310
KDB3311
KDB3312
KDB3313
KDB3314
A
149
172
249
321
393
B
89
112
189
261
333
C
179
202
279
351
423
(2+1) / (2+1) Nos.
(2+1) / (2+1) Nos
(2+1) / (2+1) Nos
(4+1) / (4+1) Nos
(4+1) / (4+1) Nos
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
1 / 1 No.
SPN DISTRIBUTION BOARD (CH) ø 26+32, K'OUT
TOP/BOTTOM
ø 32, K'OUT
LH/RH SIDE
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
162
222
78
84
BA
90
C
30
84
BA
385
445
78
No. of Ways
4
6
CAT. No.
KDB3315
KDB3316
A
324
360
B
264
300
C
331
368
(4+1) / (4+1) Nos.
(4+1) / (4+1) Nos.
1 / 1 No.
1 / 1 No.
TPN DISTRIBUTION BOARD (CH) ø 26+32, K'OUT
TOP/BOTTOM
ø 32, K'OUT
LH/RH SIDE
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Technical Specification
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
P L U G & S O C K E T E N C LO S U R E
C
460
31
146
EF
C D
140
No. of Ways
4
6
8
12
KDB3319/20/21
KDB3325/26/27
KDB3328/29
KDB3330/31
A
364
419
454
523
B
418
523
523
523
C
297
322
358
431
2 / 2 Nos.
2 / 2 Nos.
2 / 2 Nos.
2 / 2 Nos.
5 / 5 No.
7 / 7 No.
7 / 7 No.
9 / 9 No.
TPN PHASE SELECTOR DB (CH) ø 32, K'OUT
TOP/BOTTOM
ø 32, K'OUT
LH/RH SIDED
357
382
418
491
E
270
431
431
431
F
330
491
491
491
*All dimensions in millimeter.*Dimension may very ± 0.5 mm.
Aesthetic look of Plastic & Metal Combination.
Complete Shock Proof by base box earthing.
Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.
Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.
Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.
Technical Specification
B
A
CAT No.
32
First Aid in case of Electric Shock
Call an ambulance
- �Merely turning the switch off will not necessarily stop the flow of current�
head are the most dangerous routes�
What can happen if you get an electric shock�
Heart Failure �cardiac arrest� Burns
Voltage Type of current
Length of exposure time Path it takes through the body �heart or
Nerve, Muscle, and Organ Damage
When excessive electrical currents pass through the human body, the nervous
� mA - A tingling sensation is felt
��-�� mA - The heart may fibrillate; severe shock is felt
Contact with live wires is often fatal. The intensity of a shock depends on
>�� mA - Lethal. Fibrillation of the heart occurs
To treat a person who has sustained electrical injury:
system is thrown out of gear. This causes the body to react to the passage of current
Do�s in case of electrical shock :
Human body�s reaction to electric shock
through it as follows :
Which factors cause an electric shock�
��-�� mA - Muscle spasm and tightening occurs
Unplug the appliance and�or turn off the MCB �at the fuse box�
If the victim is not breathing, immediately begin mouth-to-mouth resuscitation
To prevent shock:
- Place the victim�s feet higher than the head by about a foot
- Cold, Moist Skin - Fast Heartbeat
- Cover person with a blanket or coat if available
Check for indications of shock:
- Paleness - Feeling Faint
- Skin touching against metal accessories like jewellery or a belt buckle
Take off any clothing over the burn-but only if it comes away without pulling skin along
with it
As long as the skin is unbroken, you can rinse the burn in cool, running water to ease pain
Cover any surface burns with a sterile dressing or clean cloth
Separate burnt fingers or toes with the dressing
Take the victim to the emergency room-even if the person is breathing, is conscious, and
insists that he is all right
Don�ts in case of electrical shock :
Do not touch the person with your bare hands before you are certain there is no live
electricity
Do not bandage with a towel, blanket, or cotton dressing that will stick to the wound.
�Instead, use a sheet for large area�
Take care not to break any blisters that have formed
Shield the burned area from chafing
from an explosion or fall associated with the accident.
Do not remove clothing that is stuck to the wound
If turning off the electricity is impossible or you can�t tell whether it is off �unless it is
high-voltage current�, then to approach the victim:
Stand on a mat �preferably rubber, but piled up newspapers�magazines could be used if
necessary�, and
Extend a wooden or cloth object, such as a
- The fingers and toes
- Broom handle - Chair - Piece of clothing - Rope
of high voltage. Under such circumstances keep a distance of at least �� feet
The above precautions are for your own safety.
CAUTION: For the safety of the victim, do not move him�her if spinal injury is possible
- Never put ice on a burn
- Do not apply ointments or grease to burned skin �as with burns from flames�
Sites to inspect in particular are:
What should you do if not sure if the power is off�
WARNING: Never move the person if they are touching a power line or other source
Check for burns, which may not be visible from the outside.