SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

36
T E C H N I C A L CATALOGUE SWITCHGEARS

Transcript of SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

Page 1: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

T E C H N I C A L C A T A L O G U ESWITCHGEARS

Page 2: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros
Page 3: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

ARMOR MINIATURE CIRCUIT BREAKER (MCB)

ARMOR ISOLATOR

ARMOR RESIDUAL CURRENT CIRCUIT BREAKER

ARMOR MINI CHANGEOVER SWITCH

NUEVO RE-WIREABLE SWITCH FUSE (SINGLE BREAK)

NUEVO CHANGEOVER SWITCH (OFF LOAD)

NUEVO RE-WIREABLEKIT KAT-KAT FUSE

NUEVO SHEET METAL CUT-OUT

NUEVO HRC FUSE HOLDER

NUEVO BUSBAR CHAMBER

NUEVO REVERSE FORWARDING SWITCH

SCION SPN DD DB's

SCION TPN DD DB's

SCION VERTICAL PHASE SELECTOR TPN DD DB's

SCION HORIZONTAL PHASE SELECTOR TPN DD DB's

INSPIRO SPN DB's

INSPIRO TPN DB's

MAGNA SPN DD DB’s (DL)

MAGNA TPN DD DB’s (DL)

MAGNA PHASE SELECTOR DB’s

MAGNA PLUG & SOCKET ENCLOSURE

MAGNA PLUG & SOCKET

MAGNA CAM OPERATED ROTARY SWITCH

NEX SPN SD DB’s

NEX SPN DD DB’s

NEX TPN DD DB’s

MODULAR METAL GANG BOX

MAGNA SPN SD DB’s (CH)

MAGNA SPN DD DB’s (CH)

MAGNA TPN DD DB’s (CH)

MAGNA PHASE SELECTOR DD DB’s (CH)

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

----------------------------

CONTENTS PAGE NO.

Page 4: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

Technical Specification

1

Suitable for Reverse Feed Connections (Line and Load) & Rated Breaking Capacity 10 kA.

Silver Graphite contact tips assure Antiweld Property.

Snap-On-Back mounting for 35mm x 15mm symmetrical DIN rail.

Terminals suitable for Cable + Bus bar temination.

Do not tend to bulge or wrap, when high cross sectional cables are terminated.

F

E

D

A

CB

G

TYPE

SP

SPN

DP

TP

TPN

FP

VOLTS

240/415V

240/415V

240/415V

240/415V

240/415V

240/415V

A

50

50

50

50

50

50

B

82

82

82

82

82

82

C

45.5

45.5

45.5

45.5

45.5

45.5

D

44.4

44.4

44.4

44.4

44.4

44.4

E

66.3

66.3

66.3

66.3

66.3

66.3

F

71.9

71.9

71.9

71.9

71.9

71.9

G

17.50

35.00

35.00

52.50

70.00

70.00

RATING

6A-63A

6A-63A

6A-63A

6A-63A

6A-63A

6A-63A

KSG400201/02/03/04/05/06/300/401/402

KSG400601/02/03/04/05/06/700/801/802

KSG401001/02/03/04/05/06/1100/1201/1202

KSG401401/02/03/04/05/06/1500/1601/1602

KSG401801/02/03/04/05/06/1900/2001/2002

KSG402201/02/03/04/05/06/2300/2401/2402

MINIATURE CIRCUIT BREAKER (MCB)

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

MINIATURE C IRCUIT BREAKER

CAT No.

Page 5: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

ISOLATOR

Silver Graphite contact tips for Long Last.

Knob Operatable.

Suitable for all switching and Isolation.

An isolator in a manual operated device used for disconnecting the supply.

Contact Position Indication.

TYPE

DP

TP

FP

VOLTS

240/415V

240/415V

240/415V

A

50

50

50

B

82

82

82

C

45.5

45.5

45.5

D

44.4

44.4

44.4

E

66.3

66.3

66.3

F

71.9

71.9

71.9

G

35.00

52.50

70.00

RATING

25A-100A

25A-100A

25A-100A

CAT. No.

KSG402500/2600/2700/2800/2900/3000

KSG403100/3200/3300/3400/3500/3600

KSG403700/3800/3900/4000/4100/4200

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

2

F

E

D

A

CB

G

40 A

I S O L A T O R

Technical Specification

Page 6: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

3

TYPE

DP

DP

DP

FP

FP

FP

VOLTS

240/415V

240/415V

240/415V

240/415V

240/415V

240/415V

A

50

50

50

50

50

50

B

102

102

102

102

102

102

C

45

45

45

45

45

45

D

84.4

84.4

84.4

84.4

84.4

84.4

E

35.7

35.7

35.7

35.7

35.7

35.7

F

81

81

81

81

81

81

G

35.40

35.40

35.40

71.00

71.00

71.00

RATING

16A-100A

16A-100A

16A-100A

16A-100A

16A-100A

16A-100A

KSG404901/02/5000/5100/5200/5300

KSG405401A/402A/5501A/5601A/5701A/5801A

KSG405401B/02B/5501B/5601B/5701B/5801B

KSG405901/02/6000/6100/6200/6300

KSG406401A/02A/6501A/6601A/6701A/6801A

KSG406401B/02B/6501B/6601B/6701B/6801B

RESIDUAL CURRENT CIRCUIT BREAKER

mA

30mA

100mA

300mA

30mA

100mA

300mA

H

66.80

66.80

66.80

66.80

66.80

66.80

I

77.00

77.00

77.00

77.00

77.00

77.00

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

RESIDUAL CURRENT CIRCUIT BREAKER

I

H

A

CB D E

F

G

In: 40 AI n:0.10AUn:415~50 HzIm:500 A

10000 ~

RCCB

Technical Specification

Model

Residual Current Characteristics

Rated Making and Breaking Capacity

Dielectric Strength

Rated Current (A)

Rated Voltage

Rated Frequency

Rated Residual Operating Current I n(A)

Rated Residual Non Operating Current I n

Tripping Duration

Residual Tripping Current Range

Electro-Mechanical Endurance

Connection Capacity

Installation

Range

No. of Pole

CAT No.

Page 7: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

4

No. of Amp.

25/40/63 Amp.

25/40/63 Amp.

CAT. No.

KSG404300/4400/4500

KSG404600/4700/4800

A

45.5

45.5

B

83.5

83.5

C

45.5

45.5

MINI CHANGEOVER SWITCH

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

MINI CHANGEOVER SWITCH

OU

T

4 108

1 5

2

139

12 14 16

240/415V

40 A

F

E

D

A

CB

G

TYPE

DP

FP

D

45.5

45.5

E

50.0

50.0

F

72.0

72.0

G

35.5

71.0

Technical Specification

Page 8: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

TYPE

SPN & DP

SPN & DP

TPN

TPN

TPN

TPN

TPN

FP

VOLTS

240

240

415

415

415

415

415

415

A

144

220

222

261

347

447

495

264

B

94

135

176

208

293

330

381

261

C

55

72

72

77

102

157

157

85

D

45

85

87

121

228

195

246

184

E

113

170

174

205

283

374

425

212

F

135

168

213

247

358

390

440

292

G

69

113

130

133

204

150

170

145

RATING

16A

32A

16A

32A

63A

100A

200A

32A

KSG2051/53

KSG2052/54

KSG2055

KSG2056

KSG2057

KSG2058

KSG2059

KSG2060

H

65

315

320

370

485

570

610

370

RE-WIREABLE SWITCH FUSE UNIT K'OUT

TOP/BOTTOM

Ø26, 1 / 1 Nos.

Ø26, 1 / 1 Nos.

Ø26, 3 / 3 Nos.

Ø26, 3 / 3 Nos.

Ø37, 3 / 3 Nos.

Ø37, 3 / 3 Nos.

Ø37, 3 / 3 Nos.

Ø26, 4 / 4 Nos.

THICKNESS

0.9 MM

1.0 MM

1.0 MM

1.0 MM

1.2 MM

1.5 MM

1.5 MM

1.0 MM

5

B

A E

D

C

H

Technical Specification

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

F G

REWIRABLE SWITCH FUSE UNIT

CAT. No.

Page 9: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

F

BG

C

H

D

A E

6

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

CHANGEOVER SWITCH FUSE UNIT

A

359

359

496

496

B

332

332

429

429

C

180

180

235

235

D

264

264

356

356

E

290

290

416

416

F

420

420

520

520

G

260

260

285

285

H

271

271

435

435

KNIFE TYPE

ø37, 4 / 4 Nos.

ø37, 4 / 4 Nos.

ø38, 4 / 4 Nos.

ø38, 4 / 4 Nos.

RATING

63A

100A

200A

320A

THICKNESS

1.5 MM

1.5 MM

1.5 MM

1.5 MM

TYPE

DP

TP

FP

FP

DP

FP

DP

FP

VOLTS

240

415

415

415

240

415

240

415

A

220

174

208

174

311

315

397

394

B

134

222

261

222

198

345

248

430

C

81

81

81

81

134

134

164

164

D

85

184

211

184

128

272

182

360

E

171

134

155

134

146

245

335

335

F

174

273

305

273

258

405

330

330

G

63

48

75

48

73

75

65

65

RATING

32A

32A

32A

16A

63A

63A

100A

100A

CAT. No.

KSG2061

KSG2064

KSG2066

KSG2065

KSG2062

KSG2067

KSG2063

KSG2068

H

113

96

125

96

166

166

212

212

CHANGEOVER SWITCH (OFF LOAD)

ø26, 1 / 1 Nos.

ø26, 3 / 3 Nos.

ø26, 4 / 4 Nos.

ø26, 4 / 4 Nos.

ø37, 2 / 2 Nos.

ø37, 4 / 4 Nos.

ø37, 2 / 2 Nos.

ø37, 4 / 4 Nos.

K'OUT

TOP/BOTTOMTHICKNESS

1 MM

1 MM

1 MM

1 MM

1.5 MM

1.5 MM

1.5 MM

1.5 MM

CAT NO.

KSG2069

KSG2070

KSG2071

KSG2072

Page 10: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

7

J

C

B G

H

FI A E

VOLTS

63A/415V

100A/415V

200A/415V

200A/415V

A

104

163

188

188

B

42

68

63

63

C

43

64

68

68

D

67

110

117

117

E

27

57

67

67

F

104

160

175

175

G

24

64

49

49

H

47

86

20

20

KIT KAT TURBO SERIES

I

246

J

18

26

31

31

CAT No.

KSG2031

KSG2032

KSG2033

KSG2034

VOLTS

16/240V

16/415V

32/415V H

63/415V H

100/415V

200/415V

300/415V

500/415V

A

63

74

110

133

169

193

208

208

B

29

30

37.50

49

61

63

90

90

C

38

34

43

59

65

67

90

90

D

45

50

84

98

117

117

141

141

E

32.50

37

44

45.50

60

64

59

59

F

62

74

108

134

160

183

198

198

G

14

18

32

43

56

49

47

47

H

31

37

57

77

91

92

86

86

REWIREABLE KIT KAT FUSE UNIT

J

9

10.50

10.50

17

22

22

43

43

CAT NO.

KSG2023

KSG2024

KSG2025

KSG2026

KSG2027

KSG2028

KSG2029

KSG2030

I

285

285

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Technical Specification

REWIRABLE KIT KAT FUSE UNIT

Page 11: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

8

B

D

A

FC

E

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

SHEET METAL CUT OUT

No. of Amp.

16 Amp.

32 Amp.

63 Amp.

100 Amp.

A

88.5

123.50

204

230

B

48.5

65

83

100

C

58

63

114

122

D

87

44

44

63

E

78

100

160

186

F

73

89

97

117

SHEET METAL CUT-OUT (ENCLOSURE) K'OUT

TOP/BOTTOM

ø12.5 1 / 1

ø20 1 / 1

ø26 1 / 1

ø26 1 / 1

CAT No.

KSG2035

KSG2036

KSG2037

KSG2038

THICKNESS

0.9 MM

0.9 MM

1.2 MM

1.2 MM

Surface Mounting

Light Grey Texture Finish

CRCA Sheet Steel

4 kA

2.5 kV

240 - 415V AC

IP23

690V AC

50 Hz

-5º C to 40º C

16, 32, 63 & 100 Amp.

Page 12: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

9

Technical Specification

No. of Amp.

20 Amp.

32 Amp.

63 Amp.

125 Amp.

A

67.50

97

103.50

128.50

B

27

32.50

36.70

47.50

C

31

38

43

58.50

D

42

57

64

85

E

14

13.50

14

23

F

79

103

109

136

HRC FUSE HOLDER K'OUT

TOP/BOTTOM

ø9 1 X 1

ø20 1 X 1

ø20 1 X 1

ø20 1 X 1

G

29

44

47.50

68

H

15

19

21.50

26

I

6.50

8.70

10.50

15

CAT No.

KSG2073

KSG2074

KSG2075

KSG2076

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

H R C F U S E H O L D E R

H

G

I

C

B

E FA

D

Page 13: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

E

B C

A F

D

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Surface Mounting

Light Grey Texture Finish

CRCA Sheet Steel

10kA for 1 second

2.5 kV

240 - 415V AC

690V AC

50 Hz

-5º C to 40º C

IP40

32, 63, 100 & 200 Amp. (4 Way)

B U S B A R C H A M B E R

No. of Amp.

32 Amp.

63 Amp.

100 Amp.

200 Amp.

A

203

224

318

384

B

256

310

379

460

C

108

117

138

138

D

103

114

135

133

E

200

244

305

378

F

136

158

250

316

BUSBAR CHAMBER K'OUT

TOP/BOTTOM

ø26, 4 / 4

ø30, 4 / 4

ø30, 4 / 4

ø30, 4 / 4

K'OUT

LH/RH SIDE

ø26, 4 / 4

ø26, 4 / 4

ø30, 4 / 4

ø30, 4 / 4

THICKNESS

1 MM

1 MM

1 MM

1 MM

CAT No.

KSG2046

KSG2047

KSG2048

KSG2049

10

Page 14: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

Technical Specification

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

PPI System - push and pull interlocking system.

99.99% ETP (Electrolytic Tough Pitch) copper used in static and moving parts.

Manufacturing of Bakelite block through CNC moulding.

Alignment of mechanism are fixed for long durability.

Metal handle for more strength.

Aesthetic new housing made from high quality steel.

Amp.

16 Amp.

25 Amp.

32 Amp.

CAT. No.

KSG2039

KSG2040

KSG2041

A

88

118

118

B

73

93.5

93.5

C

65

79

79

2 Nos.

2 Nos.

2 Nos.

REVERSE FORWARDING SWITCH ø 20, K'OUT

BOTTOMD

53.5

76

76

E

60.5

95.5

95.5

F

121

153.5

153.5

A

REVERSE FORWARDING SWITCH

F

C

B

D

E

Page 15: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

12

No. of Ways

4

6

8

12

16

CAT. No.

KDB3001

KDB3002

KDB3003

KDB3004

KDB3005

A

173

173

248

318

390

B

96

96

170

244

315

C

189

189

261

334

406

3 / 3 Nos.

3 / 3 Nos.

4 / 4 Nos.

6 / 6 Nos.

6 / 6 Nos.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

0.9 MM

0.9 MM

0.9 MM

0.9 MM

0.9 MM

SPN DISTRIBUTION BOARD ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDETHICKNESS

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

D I S T R I B U T I O N B O A R D

Type of Installation

Colour / Finish

Distribution Technique

Material

Busbar Rating

Dielectric Strength

Rated Short Time with Stand (Icw)

Rated Conditional Short Circuit (Ics)

Voltage Rating

Neutral Bar Terminal Capacity

Earthing Bar Terminal Capacity

Degree of Protection (IP)

Insulation Voltage (Ui)

Frequency

Ambient Temperature

Reference Standard

Incoming:

Outgoing

Range

Type

Surface & Flush Mounting

Light Grey Texture Finish

Insulated Busbar

CRCA Sheet Steel

100A

2.5 kV

5 kA for 0.1 second

10 kA

240V AC 1 Phase

16 mm2

16 mm2

IP43

690V AC

50 Hz

-5º C to 40º C

IS 8623; IS 13032; IEC 61439-3

Two pole MCBs / RCCB / Isolator

SP MCBs

4, 6, 8, 12 & 16 Ways

Double Door

Technical Specification

24

0

C

84.5

BA

14

1

22

2

81

Page 16: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

13

380

446

48

1

C101

No. of Ways

4 (4+12)

6 (4+18)

4 (8+12)

6 (8+18)

8 (8+24)

CAT. No.

KDB3006

KDB3007

KDB3008

KDB3009

KDB3010

A

251

320

320

396

396

B

180

242

242

330

330

C

260

334

334

405

405

4 / 4 Nos.

6 / 6 Nos.

6 / 6 Nos.

8 / 8 Nos.

8 / 8 Nos.

2 / 2 No.

2 / 2 No.

2 / 2 No.

2 / 2 No.

2 / 2 No.

ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

0.9 MM

0.9 MM

0.9 MM

0.9 MM

0.9 MM

THICKNESS

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

TPN DISTRIBUTION BOARD

D I S T R I B U T I O N B O A R D

Technical Specification

107

BA

Page 17: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

14

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

No. of Ways

4

6

8

CAT. No.

KDB3011/12/13

KDB3014/15/16

KBD3017/18/19

A

320

320

398

B

233

233

316

C

334

334

407

6 / 6 Nos.

6 / 6 Nos.

8 / 8 Nos.

2 / 2 No.

2 / 2 No.

2 / 2 No.

VERTICAL PHASE SELECTOR TPN DB ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

1 MM

1MM

1 MM

ø 26, K'OUT

LH/RH SIDE

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

D I S T R I B U T I O N B O A R D

Technical Specification

138

52

0

59

7

63

5

C

BA

136

Page 18: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

15

No. of Ways

4 (4+12)

CAT. No.

KDB3020/21/22

A

372

B

271

C

391 3 / 3 Nos. 1 / 1 No.

HORIZONTAL PHASE SELECTOR TPN DB ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

1 MM

THICKNESS

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

Technical Specification

Surface & Flush Mounting

Light Grey Texture Finish

Insulated Busbar

CRCA Sheet Steel

100A

2.5 kV

5 kA for 0.1 second

10 kA

240-415V AC, 3 Phase / 4 Wire

16 mm2

16 mm2

IP43

690V AC

50 Hz

-5º C to 40º C

IS 8623 : IS 13032, IEC 61439-3

Four Pole MCBs/RCCB/Isolator

SP MCBs

4 Way (4+12)

(with or without Rotary Wiring)

Double Door

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

D I S T R I B U T I O N B O A R D

28

5

36

1

388

C

14

8

BA

141

Page 19: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

16

14

2

21

5

24

0

C

88

BA

76

No. of Ways

4

6

8

12

16

CAT. No.

KDB3211

KDB3212

KDB3213

KDB3214

KDB3215

A

162

201

224

307

377

B

109

145

142

253

322

C

185

220

255

326

399

2 / 2 Nos.

3 / 3 Nos.

4 / 4 Nos.

6 / 6 Nos.

8 / 8 Nos.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

SPN DISTRIBUTION BOARD ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

0.9 MM

0.9 MM

0.9 MM

0.9 MM

0.9 MM

ø 26, K'OUT

LH/RH SIDE

Type of Installation

Colour / Finish

Distribution Technique

Material

Busbar Rating

Dielectric Strength

Rated Short Time with Stand (Icw)

Rated Conditional Short Circuit Current (Ics)

Voltage Rating

Neutral Bar Terminal Capacity

Earthing Bar Terminal Capacity

Index of Protection (IP)

Insulation Voltage (Ui)

Frequency

Ambient Temperature

Reference Standard

Incoming:

Outgoing

Range

Available in

Surface & Flush Mounting

Ivory Texture Finish

Insulated Busbar

Base Box made by CRCA Sheet Steel /

Cover made by Polycarbonate Material

100A

2.5 kV

5 kA for 0.1 second

10 kA

240V AC, 1 Phase

16 mm2

16 mm2

IP43

690V AC

50 Hz

-5º C to 40º C

IS 8623; IS 13032; IEC 61439-3

Two Pole MCBs / RCCB / Isolator

SP MCBs

4, 6, 8, 12 & 16 Ways

Metal & Plastic Base

Technical Specification

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

D I S T R I B U T I O N B OA R D

Page 20: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

17

DESCRIPTION

No. of Ways

4

CAT. No.

KDB3216

A

223

B

162

C

248 4 / 4 Nos. 2 / 2 No.

ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

1.2 MM

THICKNESS

Technical Specification

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

D I S T R I B U T I O N B OA R D

TPN DISTRIBUTION BOARD

322

390

102

41

0

C

112

BA

Page 21: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

18

79

A B

96

146

222

241

C

No. of Ways

4

6

8

12

16

CAT. No.

KDB3310

KDB3311

KDB3312

KDB3313

KDB3314

C

209

245

281

353

425

A

175

211

247

319

391

B

125

151

187

269

341

SPN DD DISTRIBUTION BOARD (DL) ø 26+32, K'OUT

TOP/BOTTOM

3 / 3 Nos.

3 / 3 Nos.

4 / 4 Nos.

6 / 6 Nos.

6 / 6 Nos.

1 MM

1 MM

1 MM

1 MM

1 MM

THICKNESS

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

ø 32, K'OUT

LH/RH SIDE

Technical Specification

Page 22: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

No. of Ways

4

6

8

12

CAT. No.

KDB3315

KDB3316

KDB3317

KDB3318

A

261

320

395

534

B

196

254

330

468

C

285

360

429

568

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

TPN DD DB (DL) ø 26+32, K'OUT

TOP/BOTTOM

ø 32, K'OUT

LH/RH SIDE

4 / 4 Nos.

6 / 6 Nos.

6 / 6 Nos.

8 / 8 Nos.

1 MM

1 MM

1 MM

1 MM

THICKNESS

OF BASE

THICKNESS

OF COVER

1.2 MM

1.2 MM

1.2 MM

1.2 MM

19

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Type of Installation

Colour / Finish

Distribution Technique

Material

Busbar Rating

Dielectric Strength

Rated Short Time with Stand (Icw)

Rated conditional short circuit current (Ics)

Voltage Rating

Neutral Bar Terminal Capacity

Earthing Bar Terminal Capacity

Degree of Protection (IP)

Insulation Voltage (Ui)

Frequency

Ambient Temperature

Reference Standard

Incoming:

Outgoing

Range

Type

107

BA

345

400

94

419

C

Page 23: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

20

C D

90

96

EF

A

B

No. of Ways

25 / 32A

40 / 63A

CAT. No.

KDB3332/34

KDB3335/36

A

198

198

B

300

300

C

139

139

5 / 5 Nos.

5 / 5 Nos.

1/1 Nos.

1/1 Nos.

PHASE SELECTOR DB ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDED

190

190

E

250

250

F

305

305

THICKNESS

1 MM

1 MM

Technical Specification

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Page 24: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

21

16

9

C

BA

15

7

59

98

63

CAT. No.

KDB3337

A

123

B

78

C

138 1 / 1 Nos. 1 / 1 No.

PLUG & SOCKET ENCLOSURE (DL) ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Technical Specification

P L U G & S O C K E T E N C LO S U R E

Page 25: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

Technical Specification

Amp.

20 Amp. (Plugs)

20 Amp. (Sockets)

CAT. No.

KDB3343

KDB3346

A

87

39

B

46

68.5

C

43

45

PLUG & SOCKET

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

P L U G & S O C K E T

B

A

C

Made of aluminium which provide highly heat absorbing capacity

as well as durability features.

Ease use.

Rust proof.

22

ABC

Page 26: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

23

Amp.

25 Amp.

32 Amp.

40 Amp.

63 Amp.

CAT. No.

KDB3349

KDB3350

KDB3351

KDB3352

A

64.5

64.5

87.5

87.5

B

64.5

64.5

87.5

87.5

C

66.5

66.5

87.5

87.5

CAM OPERATED ROTARY SWITCH

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Technical Specification

C A M O P E R AT E D R OTA R Y S W I TC H

D

48

48

68.5

68.5

E

48

48

68.5

68.5

F

100

100

125

125

OFF

13A

B

C

E

D

F

Page 27: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

No. of Ways

4

6

8

10

12

16

CAT. No.

KDB3083

KDB3084

KDB3085

KDB3086

KDB3087

KDB3088

A

121

187

224

224

262

338

B

68

134

170

170

207

284

C

131

195

235

236

274

352

2 / 2 Nos.

4 / 4 Nos.

5 / 5 Nos.

5 / 5 Nos.

6 / 6 Nos.

8 / 8 Nos.

SPN SINGLE DOOR DB

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper busbar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Distribution Boards

Technical Specification

ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

1 / 1 Nos.

1 / 1 Nos.

1 / 1 Nos.

1 / 1 Nos

1 / 1 Nos.

1 / 1 Nos.

C

19

5 10

1

18

5

60

62

B

A

24

Page 28: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper busbar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Distribution Boards

Technical Specification

C

10

1

18

6

208

84

BA

81

No. of Ways

4

6

8

10

12

16

CAT. No.

KDB3089

KDB3090

KDB3091

KDB3092

KDB3093

KDB3094

A

137

166

205

241

281

356

B

90

119

158

195

234

310

C

159

191

227

267

302

377

2/2 Nos.

3/3 Nos.

4/4 Nos.

5/5 Nos.

6/6 Nos.

8/8 Nos.

SPN DOUBLE DOOR DB

1/1 Nos.

1/1 Nos.

1/1 Nos.

1/1 Nos.

1/1 Nos.

1/1 Nos.

ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

25

Page 29: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

26

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper busbar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Distribution Boards

No. of Ways

4

6

8

12

CAT. No.

KDB3098

KDB3099

KDB3100

KDB3103

A

261

328

406

556

B

187

254

330

480

C

299

362

436

578

2 / 2 Nos.

2 / 2 Nos.

2 / 2 Nos.

2 / 2 Nos.

5 / 5 No.

7 / 7 No.

7 / 7 No.

9 / 9 No.

ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

TPN DOUBLE DOOR DB

C

31

7

38

4

41

9

98

BA

96

Technical Specification

Type of Installation

Colour / Finish

Distribution Technique

Material

Busbar Rating

Dielectric Strength

Rated Short Time withstand (Icw)

Rated Conditional Short Circuit Current (Ics)

Voltage Rating

Neutral Bar Terminal Capacity

Earthing Bar Terminal Capacity

Degree of Protection (IP)

Insulation Voltage (Ui)

Frequency

Ambient Temperature

Reference Standard

Incoming:

Outgoing

Range

Type

Page 30: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

MODULAR METAL GANG BOX

27A

BC

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

MODULE

2

3

4

6

8 (H)

8 (V)

12

16

18

CAT. No.

V5001

V5002

V5003

V5004

V5005

V5006

V5007

V5008

V5009

METAL GANG BOX ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDEA

73 MM

73 MM

73 MM

73 MM

77 MM

131 MM

130 MM

144 MM

200 MM

2 / 2 Nos.

2 / 2 Nos.

3 / 3 Nos.

5 / 5 Nos.

5 / 5 Nos.

3 / 3 Nos.

5 / 5 Nos.

5 / 5 Nos.

5 / 5 Nos.

2 / 2 Nos.

2 / 2 Nos.

2 / 2 Nos.

2 / 2 Nos.

2 / 2 Nos.

3 / 3 Nos.

3 / 3 Nos.

3 / 3 Nos.

5 / 5 Nos.

B

75 MM

105 MM

139 MM

210 MM

230 MM

135 MM

209 MM

231 MM

212 MM

C

52 MM

52 MM

52 MM

52 MM

54 MM

60 MM

60 MM

60 MM

60 MM

Technical Specification

Brass earth.

GPSP Sheet for long lasting.

Ample space for wiring.

Cap an hinges thread to prevent cement / dust at time of constructions.

Page 31: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

28

No. of Ways

1/2

3/4

6

8

12

16

KDB3301/02

KDB3303/04

KDB3306

KDB3307

KDB3308

KDB3309

A

76

96

154

190

261

333

B

46

66

124

160

231

303

C

83

103

161

197

268

340

1 / 1 Nos.

1 / 1 Nos.

2 / 2 Nos.

3 / 3 Nos.

4 / 4 Nos.

5 / 5 Nos.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

SPN SD DISTRIBUTION BOARD (CH) ø 26, K'OUT

TOP/BOTTOM

ø 26, K'OUT

LH/RH SIDE

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

Surface & Flush Mounting

Light Grey Texture Finish

Insulated Busbar

CRCA Sheet Steel

100A

2.5 kV

5 kA for 0.1 second

10 kA

240V AC, 1 Phase

16 mm2

16 mm2

IP40

690V AC

50 Hz

-5º C to 40º C

IS:8623, IS:13032, IEC:61439-3

Two Pole MCBs/RCCB/Isolator

SP MCBs

4 Way to 16 Way

Single Door

Technical Specification

C

CAT. No.

Page 32: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

29

Technical Specification

No. of Ways

4

6

8

12

16

CAT. No.

KDB3310

KDB3311

KDB3312

KDB3313

KDB3314

A

149

172

249

321

393

B

89

112

189

261

333

C

179

202

279

351

423

(2+1) / (2+1) Nos.

(2+1) / (2+1) Nos

(2+1) / (2+1) Nos

(4+1) / (4+1) Nos

(4+1) / (4+1) Nos

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

1 / 1 No.

SPN DISTRIBUTION BOARD (CH) ø 26+32, K'OUT

TOP/BOTTOM

ø 32, K'OUT

LH/RH SIDE

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

162

222

78

84

BA

90

C

Page 33: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

30

84

BA

385

445

78

No. of Ways

4

6

CAT. No.

KDB3315

KDB3316

A

324

360

B

264

300

C

331

368

(4+1) / (4+1) Nos.

(4+1) / (4+1) Nos.

1 / 1 No.

1 / 1 No.

TPN DISTRIBUTION BOARD (CH) ø 26+32, K'OUT

TOP/BOTTOM

ø 32, K'OUT

LH/RH SIDE

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Technical Specification

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

P L U G & S O C K E T E N C LO S U R E

C

460

Page 34: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

31

146

EF

C D

140

No. of Ways

4

6

8

12

KDB3319/20/21

KDB3325/26/27

KDB3328/29

KDB3330/31

A

364

419

454

523

B

418

523

523

523

C

297

322

358

431

2 / 2 Nos.

2 / 2 Nos.

2 / 2 Nos.

2 / 2 Nos.

5 / 5 No.

7 / 7 No.

7 / 7 No.

9 / 9 No.

TPN PHASE SELECTOR DB (CH) ø 32, K'OUT

TOP/BOTTOM

ø 32, K'OUT

LH/RH SIDED

357

382

418

491

E

270

431

431

431

F

330

491

491

491

*All dimensions in millimeter.*Dimension may very ± 0.5 mm.

Aesthetic look of Plastic & Metal Combination.

Complete Shock Proof by base box earthing.

Equipped with insulated copper bus bar rating up to 100Ampere that prevents short circuit current.

Ample wiring Space is provided to ensure proper distribution of Neutral and Earth Wires.

Masking Sheet (Dust Guard) offers added safely by prevent cement from entering.

Technical Specification

B

A

CAT No.

Page 35: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

32

First Aid in case of Electric Shock

Call an ambulance

- �Merely turning the switch off will not necessarily stop the flow of current�

head are the most dangerous routes�

What can happen if you get an electric shock�

Heart Failure �cardiac arrest� Burns

Voltage Type of current

Length of exposure time Path it takes through the body �heart or

Nerve, Muscle, and Organ Damage

When excessive electrical currents pass through the human body, the nervous

� mA - A tingling sensation is felt

��-�� mA - The heart may fibrillate; severe shock is felt

Contact with live wires is often fatal. The intensity of a shock depends on

>�� mA - Lethal. Fibrillation of the heart occurs

To treat a person who has sustained electrical injury:

system is thrown out of gear. This causes the body to react to the passage of current

Do�s in case of electrical shock :

Human body�s reaction to electric shock

through it as follows :

Which factors cause an electric shock�

��-�� mA - Muscle spasm and tightening occurs

Unplug the appliance and�or turn off the MCB �at the fuse box�

If the victim is not breathing, immediately begin mouth-to-mouth resuscitation

To prevent shock:

- Place the victim�s feet higher than the head by about a foot

- Cold, Moist Skin - Fast Heartbeat

- Cover person with a blanket or coat if available

Check for indications of shock:

- Paleness - Feeling Faint

- Skin touching against metal accessories like jewellery or a belt buckle

Take off any clothing over the burn-but only if it comes away without pulling skin along

with it

As long as the skin is unbroken, you can rinse the burn in cool, running water to ease pain

Cover any surface burns with a sterile dressing or clean cloth

Separate burnt fingers or toes with the dressing

Take the victim to the emergency room-even if the person is breathing, is conscious, and

insists that he is all right

Don�ts in case of electrical shock :

Do not touch the person with your bare hands before you are certain there is no live

electricity

Do not bandage with a towel, blanket, or cotton dressing that will stick to the wound.

�Instead, use a sheet for large area�

Take care not to break any blisters that have formed

Shield the burned area from chafing

from an explosion or fall associated with the accident.

Do not remove clothing that is stuck to the wound

If turning off the electricity is impossible or you can�t tell whether it is off �unless it is

high-voltage current�, then to approach the victim:

Stand on a mat �preferably rubber, but piled up newspapers�magazines could be used if

necessary�, and

Extend a wooden or cloth object, such as a

- The fingers and toes

- Broom handle - Chair - Piece of clothing - Rope

of high voltage. Under such circumstances keep a distance of at least �� feet

The above precautions are for your own safety.

CAUTION: For the safety of the victim, do not move him�her if spinal injury is possible

- Never put ice on a burn

- Do not apply ointments or grease to burned skin �as with burns from flames�

Sites to inspect in particular are:

What should you do if not sure if the power is off�

WARNING: Never move the person if they are touching a power line or other source

Check for burns, which may not be visible from the outside.

Page 36: SWITCHGEARS TECHNIC AL CATALOGUE - Fybros

1800-270-6334