Switch wiring for LynTec SS-2PL, SS-2DPL, SS-2LRP and SS-4LRP

2
+ + IN/OUT IN/OUT For use with LynTec systems T-568B only GREEN - On N/O BROWN - Keylock/ BLUE - PLT +/- ORANGE - Off N/O Common PILOT PILOT OFF ON OFF ON DEFAULT BYPASS KEYLOCK ON COM PILOT OFF IN/OUT IN/OUT IN/OUT IN/OUT For use with LynTec systems For use with LynTec systems T-568B only T-568B only GREEN - On N/O BROWN - Keylock/ BLUE - PLT +/- ORANGE - Off N/O GREEN - On N/O BROWN - Keylock/ BLUE - PLT +/- ORANGE - Off N/O Common PILOT PILOT OFF ON OFF ON DEFAULT BYPASS KEYLOCK PILOT PILOT OFF ON OFF ON DEFAULT BYPASS KEYLOCK ON COM PILOT OFF PILOT PILOT OFF ON OFF ON DEFAULT BYPASS KEYLOCK First Sequencer Board (Top) Power & Kill Connector (4 pin) NOT in PDS-10 See daisy-chain connections below for wiring between PDS-10s or multiple cabinets. OFF Busy Kill Carry Com 24v AC V– N/C Cascade Connector (4 pin) Hold Com Kill ON Pilot Borrow 24v AC N/C Last Sequencer Board (Bottom) Last Cascade Connector (4 pin) Power & Kill Connector (4 pin) Hold Com Carry Com Busy +5v Logic Kill Borrow Pilot Install Jumper in LAST sequencer board. V+ V– OFF Com Pilot ON OFF Test button Kill — Fire alarm shutdown External contact closure lights the red Kill LEDs and kills all sequenced power. Contact opening restarts the ON sequence. ON Hold Borrow Pilot Com Carry Com Busy +5v Logic Kill V+ V– OFF Com Pilot ON Test button PILOT LED (green) Press white levers back with small straight-blade screwdriver to insert stripped wires. For single sequencer board hookup connect OFF switch normally open to off Left Bus IN 24V OFF Digital I/O OFF I/O #1 reserved for EO function I/O #6 reserved for EL function SS-2LRP SS-2LRP SS-2PL & SS-2DPL RPC Controller Switch wiring for LynTec SS-2PL, SS-2DPL, SS-2LRP and SS-4LRP RPC & RPCR Wiring NPAC & XPC Wiring MS & PDS Wiring Common GREEN - On N/O BROWN - Keylock/ BLUE - PLT +/- ORANGE - Off N/O When daisy-chaining switch sets, make sure that the jumper settings are all the same Alternate 4-wire terminal ON COM PILOT OFF ON COM PILOT OFF 1 2 3 4 5 6 139-0698-00.2 SS-2 insert 9/20/19

Transcript of Switch wiring for LynTec SS-2PL, SS-2DPL, SS-2LRP and SS-4LRP

Page 1: Switch wiring for LynTec SS-2PL, SS-2DPL, SS-2LRP and SS-4LRP

+

+

IN/OUT IN/OUTFor use with

LynTec systems

T-568B only

GREEN - On N/OBROWN - Keylock/

BLUE - PLT +/-ORANGE - O� N/O

Common

PILO

TPI

LOT

OFF ON

OFF ON

DEFAULT

BYPASSKEYLOCK

ON

COM

PILOT

OFF

IN/OUT

IN/OUT

IN/OUT

IN/OUT

For use with LynTec systems

For use with LynTec systems

T-568B only

T-568B only

GREEN - On N/OBROWN - Keylock/

BLUE - PLT +/-ORANGE - O� N/O

GREEN - On N/OBROWN - Keylock/

BLUE - PLT +/-ORANGE - O� N/O

Common

PILO

TPI

LOT

OFF ON

OFF ON

DEFAULT

BYPASSKEYLOCK

PILO

TPI

LOT

OFF ON

OFF ON

DEFAULT

BYPASSKEYLOCK

ON

COM

PILOT

OFF

PILO

TPI

LOT

OFF ON

OFF ON

DEFAULT

BYPASSKEYLOCK

FirstSequencerBoard (Top)

Power & KillConnector

(4 pin)

NOT in PDS-10See daisy-chain

connections below for wiring between

PDS-10s or multiple cabinets.

OFFBusy

Kill CarryCom24vAC

V–N

/C

CascadeConnector

(4 pin)

HoldCom Kill ON

Pilot

Borrow

24vAC N

/C

LastSequencer

Board (Bottom)

Last

CascadeConnector

(4 pin)

Power & KillConnector

(4 pin)Hold Com CarryCom Busy+5v

Logic KillBorrow Pilot

Install Jumper in LAST sequencer board.

V+ V– OFFCom PilotON

OFFTest button

Kill — Fire alarm shutdownExternal contact closure lights the red Kill LEDs and kills all

sequenced power. Contact opening restarts the ON sequence.

ON

Hold Borrow Pilot Com CarryCom Busy+5v

Logic KillV+ V– OFFCom PilotON

Test button

PILOTLED

(green)

Press white levers back with

small straight-blade screwdriver to insert

stripped wires.

For single sequencer board hookup connect OFF switch normally open

to o�

Left Bus

IN24VOFF

Digital I/O

OFF

I/O #1 reserved for EO function

I/O #6 reserved for EL function

SS-2LRP

SS-2LRP

SS-2PL & SS-2DPL

RPC Controller

Switch wiring for LynTec SS-2PL, SS-2DPL, SS-2LRP and SS-4LRP

RPC & RPCR Wiring

NPAC & XPC Wiring

MS & PDS Wiring

Common

GREEN - On N/OBROWN - Keylock/

BLUE - PLT +/-ORANGE - O� N/O

When daisy-chaining switch sets, make sure

that the jumper settings are all the same

Alternate 4-wire terminal

ON

COM

PILOT

OFF

ON

COM

PILOT

OFF

1

2

3

4

5

6

139-0698-00.2 SS-2 insert 9/20/19

Page 2: Switch wiring for LynTec SS-2PL, SS-2DPL, SS-2LRP and SS-4LRP

LOCKED

LOC

KE

D

ON

OFF

OFF

ON

OFF

ON

OFF

ON

ON

OFF

.770

" x

.535

"

PO

WER

AM

PS

OU

TSID

EO

NLY

OU

TSID

EO

NLY

VID

EO

SYSTE

MA

.C.

PO

WER

Pow

er A

mplif

iers

ON

LY

ON

LY

ON

LY

PR

OJE

CTO

RA

.C.

PO

WER

AU

TOM

IX

AU

TOM

IX

LOW

ER

BO

WL

LOW

ER

BO

WL

ON

LY

LynTec.com LynTec.com LynTec.com LynTec.com LynTec.com

LynTec.com LynTec.com LynTec.com LynTec.com LynTec.com

A p

arti

al s

ampl

e of

cus

tom

film

lege

nds

Cus

tom

sw

itch

lege

nds

you

can

prin

t on

your

lase

r pr

inte

rS

ee h

ttp://

ww

w.ly

ntec

.com

/139

-030

9_C

SLF

-1_F

ilm.p

df

SO

UN

D S

YSTE

MA

.C.

PO

WER

FLAS

HES D

URIN

G SE

QUEN

CING

ON

LynTec.com

SO

UN

D S

YSTE

MA

.C.

PO

WER

OFF

LynTec.com

Op

tio

nal

Key

-Lo

ck S

wit

chS

S-2

PL

Seq

uenc

er S

witc

h is

a c

ombi

natio

n of

a

SS

-2 S

witc

h S

et w

ith a

KS

-2L

Loc

king

Sw

itch,

mou

nted

on

a si

ngle

gan

g st

ainl

ess

stee

l wal

l pla

te.

Mec

hani

cal l

ayou

t on

reve

rse

side

.

LynT

ecA

.C. S

eque

ncin

g S

yste

ms

Wir

e re

qu

irem

ents

Sw

itch

set t

o se

quen

cer:

4 c

ondu

ctor

s.B

etw

een

dais

y ch

aine

d se

quen

cers

: 9

cond

ucto

rs, 1

1 if

Pow

er V

ouch

ers

are

used

.U

p to

250

0 ft.

run

: 24

ga.

2,50

0 to

3,7

50 ft

. run

: 22

ga.

To

LynT

ecP

DS

, MR

TS

, MS

LC

, S

LC

, MS

P o

r S

P

serie

s se

quen

cer

CO

M

OF

F

PIL

OT

LE

D +

ON

To

FIR

ST

seq

uenc

er if

dai

sy c

hain

ed.

Rea

r vi

ew w

iring

dia

gram

1.25

" m

in.

LynTec

oneSS-2 Sequencer Switch Set

Up to 5 additional remote control locations may be added to the system with

additional switch sets or with other momentary switches.

139-0698-00.1 SS-2 insert 9/20/19

NC NO C

NC NO C+

Rubb

eran

ti-ro

tation

gask

et

Max

imum

Pan

el

Thi

ckne

ss: .

25"

See

rev

erse

sid

e fo

r m

ultip

le s

witc

h se

t wiri

ng.

To

FIR

ST

seq

uenc

er if

dai

sy c

hain

ed.

To

LA

ST

seq

uenc

er if

dai

sy c

hain

ed.

Rock cap

while

pullin

gou

twar

dto

remo

ve.

idec AL6

–M12v L

EDid

ec AB

6–M

show

nun

lock

ed(a

ctiv

e)

Sw

itch

Spe

cific

atio

ns:

SP

DT

mom

enta

ryC

onta

cts:

24v

@0.

7ALE

D: 1

2v A

C/D

C@

10m

a.

Ver

tical

mou

ntin

g

Hor

izon

tal m

ount

ing

1.00

"

1.00

"

1.00

"

1.00

"

1.50

"1.

50"

.625

" di

a. h

ole.

(5/

8")

Max

imum

pan

elth

ickn

ess:

.250

" (1

/4")

If m

ount

ed v

ertic

ally

, lea

ve th

is m

uch

spac

e fo

r ea

sy le

ns c

ap r

emov

al.

Act

ual s

ize

drill

tem

plat

es

SS

-2 S

witc

h S

etop

tiona

l KS

-2L

Loc

king

Sw

itch

with

tum

bler

pos

ition

labe

l..7

50"

x .6

40"

doub

le-D

or

.750

" di

a. h

ole.

SS

-2 S

witc

h S

et

ON

OFF

0.71

0"

1.00

"

0.93

0"

13

8