Surge Protection Module · Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Optical...

4
© 2018 Wenzhou Arrester Electric Co., Ltd. Specifications are subject to change without notice. Revised: 10/16/18 Description Features Build-in LED Indication, saves maintenance time by identifying replacement need Thermally Protected Suitable for use in luminaire with Class I or Class II insulation 10kA Maximum Discharge Current (Imax), 8/20µs SurgeProtectionModule LED Lighting Surge Protection Module > SLP10GI SLP10GI Module Series LSP’s SLP10GI thermally protected Surge Protective Device is a self-protected device specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It has been developed with LSP’s thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under extreme circumstances of varistor end-of-life or sustaining over voltage conditions. The SLP10GI features a built-in LED indicator that notifies when replacement of the module is needed. Applications • Outdoor and Commercial LED Lighting • Roadway lighting • Traffic lighting • Digital signage • Wall wash lighting • Parking garage lighting • Flood lighting • Tunnel lighting • Street lighting High line-to-earth/ground resistance IP66: Dust-tight and water resistant Parallel or Series connected options IEC 61643-11/EN 61643-11 recognizedSee ‘ Part Numbering System’ for exact details of voltages available for Class I and Class II installations, and ‘Device Ratings and Specifications’ table for voltage specific approvals. CAUTION: Stresses above those listed in ‘Absolute Maximum Ratings’ may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Absolute Maximum Ratings • For ratings of individual members of a series, see Device Ratings and Specifications chart SLP10GI Series Units Continuous: Steady State Applied Voltage: Max AC Voltage Range (VM(AC)RMS) 150 to 510 V Continuous Current 3.5 A Transient: Maximum Discharge Current, 8/20μs Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20µs Waveform (In) 5,000 A Operating Ambient Temperature Range (TA) -40 to +85 °C Storage Temperature Range (TSTG) -40 to +85 °C Isolation Voltage Capability (When the thermal disconnect opens) 600 V Insulation Resistance >1,000 1 www.lsp-international.com

Transcript of Surge Protection Module · Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Optical...

Page 1: Surge Protection Module · Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Optical Light ON: SPD is functional Light OFF: SPD has reached end-of-life Max earth leakage

© 2018 Wenzhou Arrester Electric Co., Ltd.Specifications are subject to change without notice.

Revised: 10/16/18

Description

Features

• Build-in LED Indication, saves maintenance time by identifying replacement need • Thermally Protected• Suitable for use in luminaire with Class I or ∗Class II insulation • 10kA Maximum Discharge Current (Imax), 8/20µs

Surge�Protection�ModuleLED Lighting Surge Protection Module > SLP10GI

SLP10GI Module Series

LSP’s SLP10GI thermally protected Surge Protective Device is a self-protected device specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It has been developed with LSP’s thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under extreme circumstances of varistor end-of-life or sustaining over voltage conditions.

The SLP10GI features a built-in LED indicator that notifies when replacement of the module is needed.

Applications

• Outdoor and Commercial LED Lighting• Roadway lighting• Traffic lighting• Digital signage• Wall wash lighting• Parking garage lighting• Flood lighting• Tunnel lighting• Street lighting

• High line-to-earth/ground resistance• IP66: Dust-tight and water resistant• Parallel or Series connected options• IEC 61643-11/EN 61643-11 recognized∗

∗ See ‘Part Numbering System’ for exact details of voltages available for Class I and Class II installations, and ‘Device Ratings and Specifications’ table for voltage specific approvals.

CAUTION: Stresses above those listed in ‘Absolute Maximum Ratings’ may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.

Absolute Maximum Ratings

• For ratings of individual members of a series, see Device Ratings and Specifications chart

SLP10GI Series Units

Continuous:Steady State Applied Voltage: Max AC Voltage Range (VM(AC)RMS) 150 to 510 V Continuous Current 3.5 ATransient: Maximum Discharge Current, 8/20μs Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20µs Waveform (In) 5,000 AOperating Ambient Temperature Range (TA) -40 to +85 °CStorage Temperature Range (TSTG) -40 to +85 °CIsolation Voltage Capability (When the thermal disconnect opens) 600 VInsulation Resistance >1,000 MΩ

1 www.lsp-international.com

Page 2: Surge Protection Module · Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Optical Light ON: SPD is functional Light OFF: SPD has reached end-of-life Max earth leakage

Surge�Protection�ModuleLED Lighting Surge Protection Module > SLP10GI

SLP10GI Module Series

© 2018 Wenzhou Arrester Electric Co., Ltd.Specifications are subject to change without notice.

Revised: 10/16/18

Glossary:

1. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD.

2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs

current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect.

3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20µs current waveform.

4. MLV: Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20μs nominal discharge current (In);

Specification Value Condition

240V 277V

Temporary Overvoltage (V) TOV U @ tT T = 5 s 337 403 LV System Fault for TN Power Grid

Temporary Overvoltage (V) TOV U @ tT T = 120 min 442 529 LV System Fault for TN Power Grid

Power grids TN TN

Backup fuse (A) 16 20 Maximum gG Fuse

End of life indicationOptical

Light ON: SPD is functional Light OFF: SPD has reached end-of-life

Max earth leakage current at U ( A)C μ 50 50

IEC 61643-11 Test Classification Class II and III Class II and III

EN 61643-11 Type Classification Type 2 and 3 Type 2 and 3

YesYes

2 www.lsp-international.com

5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In);

a rounding voltage value of maximum measurement.

an average voltage value of 15 impulses

SLP10GI Series Device Ratings and Specifications

SLP10GI150S --120 150 10,000 5,000L-N:650L-G:1280N-G:1230

--

SLP10GI275S X240 275 10,000 5,000L-N:1080L-G:1230N-G:1340

L-N: 1300L-G/PE: 2400N-G/PE: 2200

SLP10GI320S X277 320 10,000 5,000L-N: 1260L-G: 1260N-G:1300

L-N: 1400L-G/PE: 2400N-G/PE: 2200

SLP10GI510S 480 510 10,000 5,000L-N: 1800L-G: 1900N-G: 1410

--

SLP10GI510P 480 510 10,000 5,000L-N: 1800L-G: 1900N-G: 1410

--

SLP10GI420S 347 420 10,000 5,000L-N: 1530L-G: 1550N-G: 1410

--

--

--

SLP10GI420P 347 420 10,000 5,000L-N: 1530L-G: 1550N-G: 1410

--

--

--

SLP10GI320P X277 320 10,000 5,000L-N: 1260L-G: 1260N-G:1300

L-N: 1400L-G/PE: 2400N-G/PE: 2200

SLP10GI275P X240 275 10,000 5,000L-N:1080L-G:1230N-G:1340

L-N: 1300L-G/PE: 2400N-G/PE: 2200

SLP10GI150P --120 150 10,000 5,000L-N:650L-G:1280N-G:1230

--

IEC/EN 61643-11

Operating Voltage(VAC)

C 1MCOV/U

(VAC)

Maximum Discharge Current 2 Imax (A)

Nominal Discharge Current 3

In (A)

MLV (V)

Up 5

(V)Type Parallel/

Series

P

S

P

S

P

S

P

S

P

S

4

Page 3: Surge Protection Module · Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Optical Light ON: SPD is functional Light OFF: SPD has reached end-of-life Max earth leakage

Surge�Protection�ModuleLED Lighting Surge Protection Module > SLP10GI

SLP10GI Module Series

Repetitive Surge Capability

Pulse Rating(8x20µSec)

Strikes Surge

1 10,000A

2 7,000A

15 5,000A

100 1,500A

1,000 700A

10000

1000

100

10

110 100 1000 10000

IMPULSE DURATION (μs)

SU

RG

E C

UR

RE

NT

(A

)

MODEL SIZE = 20MMoT = -55 C A TO o 85 C

100000

104105

106

1

2

102

103

15

130

to 625VM(AC RA) TING

28.6±1.5

100.0±20.0

46.0

±1.

5

37.0

±1.

5

Ø4.8±0.5

Red

Blue

Green withYellow stripe

10.0±2.0

Ø4.8±0.5

46.6±1.5

26.0

±1.

5

Dimensions are in millimeters (mm)4.

Notes:

22. Wire Gauge: 1.5mm , wire length: 100mm±20mm, wire stripping length:10±2mm.

3. Caution: Line/neutral wires must be correctly connected to AC power grid. Wiring error on line/neutral polarity may cause module failure.

100.0±20.0

100.0±20.0

46.0

±1.

5

37.0

±1.

5

Red Red

Blue

Blue

Input Output

Green withYellow stripe

10.0±2.010.0±2.0

Ø4.8±0.5

Dimensions

46.6±1.5

26.0

±1.

5

28.6±1.5

Series Version

Parallel Version

1. Red: Line; Blue: Neutral; Green-Yellow Stripe: Earth/Ground.

3 www.lsp-international.com

Ø4.8±0.5

10.0±0.5

7.0±

0.5 Ø2.8±0.5

10.0±0.5

7.0±

0.5

Ø2.8±0.5

© 2018 Wenzhou Arrester Electric Co., Ltd.Specifications are subject to change without notice.

Revised: 10/16/18

L

N

PE

L

N

PE

L'

N'

Series VersionParallel Version

LED Light MOV GDTThermal Fuse

Basic circuit diagram

Page 4: Surge Protection Module · Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Optical Light ON: SPD is functional Light OFF: SPD has reached end-of-life Max earth leakage

Part Numbering System Part Numbering System

SLP 10G I 275 P

Surge Protection Module

Built-in LED indication

P: Parallel connection S: Series connection

10kA (Maximum Discharge Current)

Maximum Continuous Operating Voltage

Application/Installation Schematic

Note: Green LED light on: SPD is goodGreen LED light off: SPD needs replacement

L

N

G/PE

Series Connection

G/PE

SPD

SLP10GI

N

+

-

AC/DC

Power

Supply LED Module

L

Parallel Connection

L

N

G/PE

G/PE

N

+

-

AC/DC

Power

Supply LED Module

L

SPD

SLP10GI

Surge�Protection�ModuleLED Lighting Surge Protection Module > SLP10GI

SLP10GI Module Series

© 2018 Wenzhou Arrester Electric Co., Ltd.Specifications are subject to change without notice.

Revised: 10/16/18

4 www.lsp-international.com