2. InstallationRemove the Thermostat Face1.RemovethethermostatFrontModulefromthePowerModulebyopeningthedoorandlooseningthescrew.2. PulloutwardnearthebottomontheFrontModuleandliftoff.
Prepare the Wiring1.Findalocationforyourthermostat.Itissuitableforindooruseonly,oninsulatedoruninsulatedwalls.Locateitabout41⁄2feetto5feetabovetheflooronaninsidewall.Makesureitiswellventilatedandnotlocatedinaconfinedspacesuchasasmallclosetorcabinet.Avoidplacingitnearotherheatsourcessuchashot-waterpiping,heatduct,wall-mountlighting,anddirectsunlighttohelppreventadverselyaffectingthethermostat.2. Turnoffthepowertothefloorwarmingsystematthemaincircuitpanelbeforedoinganyelectricalwork.3. Aqualifiedelectricianshouldrunadedicatedcircuitfromthemaincircuitpaneltothethermostatlocation.4. Ifadedicatedcircuitisnotpossible,youmaytapfromanothercircuitintheroom.Makesurethereisenoughloadcapacity(amps)tohandletheadditionofyourfloorwarmingsystem,andthatitisNOTwiredinserieswithanyotherdevice,includingotherGFCIs.
Owner’s ManualYour new SunStat Pro thermostatisdesignedtocontrolthevoltagetoeithera120VACor240VACresistivefloorwarmingsystem.
Pleasefollowthismanualforcompleteinstallationandoperationinstructions.Ifyouhaveanyquestionsorcomments,trycallingTechnicalSupportat1-888-432-8932.
CAUTION:Makesureyouarequalifiedandarefamiliarwithhousewiring.Thisisalinevoltagedevicethatcouldcauseseriousinjuryordamageifimproperlyinstalled.
Connect Wires1.Matchandconnectthetwowiresmarked“LINE1”and“LINE2”tothepowersupplywiresusingthewirenutsprovided.2. Gentlytugonthewirestomakesuretheyaresecure,otherwiseawirecouldloosenandcausefailure.3. Overwrapthewirenutswithelectricaltapetobettersecurethemtothewires.4.Matchandconnectthetwowiresmarked“LOAD1”and“LOAD2”tothefloorwarmingsystemleadwiresandsecurethesewiresthesameway.5. Connectthehousegroundwiretothegreenorbareleadwire(s)ofyourfloorwarmingsystem.6. Inserttheendsofthefloorsensorwireintothe“SENSOR”terminals(1and2)andtightenthescrews.Thereisnopolarity,soitdoesnotmatterwhichwireendgoesintowhichterminal.
CAUTION:Beforecontinuing,makesureyourpowersupplyvoltagematchesthevoltageratingofyourfloorwarmingsystem.Connecting240Vtoa120Vfloorwarm-ingsystemwillcauseoverheatinganddamagetothesystemandmaydamagethecontrol,otherwiring,floorcoverings,etc.
Remote Control1. Ifyouwanttoconnectyourthermostattoaremotecontroldevice,suchasahomeautomationsystem,firstmakesurethattheremotedevicehasa“drycontact”output(anun-energizedswitch,suchasthecontactsonarelay).Manyhomeautomationsystemscomewithsuchanoutputthatopensorclosesatspecifiedtimes.2. Pull2-conductorwire,size18-to24-gage,throughthewallfromtheremotedevice,intothiselectricalbox.3. Connectthewireendsintothe“SETBACK”terminals(5and6)andtightenthescrews(nopolarity).SunStat Relays1. IfyouwanttouseyourthermostattodriveaSunStatRelay(s)(askyourdealeraboutthisconvenientwaytocontrollargersystemswithonethermostat),firstreadandfollowtheinstructionsfortheSunStatRelaythoroughly.2. Pull2-conductorwire,size18-to24-gage,throughthewallfromtheSunStatRelay,intothiselectricalbox.Thiswiremaybeupto100feet(30m)inlengthfromthethermostattothelastSunStatRelayinstalled.3. Connectthewireendsintothe“RELOUT”terminals(3and4)andtightenthescrews(ObservepolarityofthewireswhenconnectingtotheSunStatRelay).Mount the Thermostat1.Carefullyfoldandpressthewiresbackintotheelectricalbox.Donotusethethermostattopushthemin,asthismaycauseconnectionstoloosenandpossiblefailure.2. SecurethethermostatPowerModuleintotheboxwiththemountingscrewsprovided.3. CarefullysnaptheFrontModuleontothePowerModule.4. Tightenthescrew.5. Switchonthepoweratthemaincircuitpanel.NOTE to contractors:After installing the thermostat, be sure to: a. Do a Quick Setup (section 3), b. Temporarily override the setpoint
SunStatProProgrammableThermostat
Model500670
3. PresstheHOLD/RETURNbuttonorwait15secondsandthethermostatwillreturntothenormaloperatingmode,savingyourselection.ThethermostatwillnowdisplayaP1,P2,P3,orP4atthebottomright.
3. Quick SetupOn/Off SwitchYourthermostatshouldbeturnedoffwhenitisfirstinstalled.ThedisplaywillshowOFFandthetimeandday.1.Slidetheon/offswitchtotheupperposition,turningthethermostaton.Thedisplaywillshowthetimeandday,temperatures,andotherinformation.2. Toturnthethermostatoffanytime,slidetheon/offswitchtothelowerposition.Noheatingwilloccurandallprogrammingisretained.
Change Format Between °F / 12-hour and °C / 24-hourYourthermostatisfactorysettooperateineither°F/12hourformator°C/24hour(militarytime)format.Ifneeded,youmaychangethisatanytimeasfollows:1.PresstheOPTIONSbuttonandholdfor1second.An°Fand12hwillshowonthedisplay.2. Pressthedownorupbuttontotoggleto°Cand24h.3. PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
Set the Current Time and Day1.PresstheDAY/TIMEbuttonandholdfor1second.Thehourshouldbeblinking.2. Pressthedownorupbuttontoadjustthehour.3. PresstheDAY/TIMEbuttonbriefly.Theminutesshouldbeblinking.4. Pressthedownorupbuttontoadjusttheminutes.5. PresstheDAY/TIMEbuttonbriefly.Thedayshouldbeblinking.6. Pressthedownorupbuttontoadjusttheday.7. PresstheHOLD/RETURNbuttonorwait15secondsandthethermostatwillreturntothenormaloperatingmode,savingyoursettings.
MO
SET TEMP
FLOORCYCLE
MA
°F
1-4
Customized Program Schedule (User)Tocustomizetheprogramsheduletomeetyourneeds,followthesesteps:
1.PressthePROGRAMbuttonandholdfor1second.ProandU1, P1, P2, P3, or P4willshowonthedisplay.2.PressthedownorupbuttontoselectU1.3.PressthePROGRAMbuttonbriefly.CYCLE 1andMOthroughFRwillshowonthedisplay.Thehourshouldbeblinking.4.Pressthedownorupbuttontoadjustthehour.5.PressthePROGRAMbuttonbriefly.Theminutesshouldbeblinking.6.Pressthedownorupbuttontoadjusttheminutes.7.PressthePROGRAMbuttonbriefly.Thesetpointtemperatureshouldbeblinking.8.Pressthedownorupbuttontoadjustthesetpointtemperature. Note: A good rule of thumb is to adjust this about 5 to 8°F (3 to 5 °C) lower during cycles when you are away to help reduce energy use. If you set the “away” cycles too low, it will take much longer to raise the temperature again and may result in unsatisfying performance. Note: Some wood and laminate floor manufacturers recommend a maximum of 82 to 84°F (27° to 28°C). Check with manufacturer.9.PressthePROGRAMbuttonbrieflytomovetothenextcyclenumber.10. RepeatSteps3through7toadjusttheremainingcycletimesandsetpointtemperaturesMOthroughFR,andfortheotherdaysoftheweek.11.Whenyoufinish,oratanytimeduringtheseadjustments,presstheHOLD/RETURNbuttonorwait30secondsandthethermostatwillreturntothenormaloperatingmode.Youradjustmentswillbesaved.
Note: The display in normal operating mode will not show a “U1” indicating “User” schedule. Also, all schedule adjustments are saved in memory and will not be lost during power failure.
Note: If you only want to use two cycles during a day, clear the other cycles by reducing their temperature below 40°F (4.5°C) to show (---). To use these cycles again, adjust their time and temperature.
frompowersupply
on/off
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Use the Factory Programmed “User” ScheduleIfyouwanttobeginusingyourthermostatnowwithoutmakinganychangestothefactorysetprogrammingschedule,youmayskiptosection“5 Operation”.Itwilloperateinthe“User”Schedule(U1),pre-programmedasfollows,andcanbecustomizedlatertoyourneeds(seesection“4 Additional Setups”):
4. Additional SetupsLifestyle Program Schedules (Presets)Thereareconvenientschedulesalreadysetuptomeettypicallifestyles.IfyouseeascheduleP1throughP4youlike,selectoneasfollows:
1.PressthePROGRAMbuttonandholdfor1second.ProandU1, P1, P2, P3, or P4willshowonthedisplay.2. PressthedownorupbuttonbrieflytoselectP1,P2,P3,orP4.Theseschedulesarenotabletobemodified,andareasfollows:
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
tofloorwarmingsystem
1. Preparation1.Unpackyourthermostatandmakesureeverythingisingoodcondition:•Thermostat•Floor sensor•Small screwdriver•Mounting screws•Wire nuts for wiring connectionsIfanypartsaremissingordamaged,contactthestorewhereyoupurchasedthisthermostat.Donotinstalladamagedpart.
2. Gatherthefollowingtoolsandsupplies: •Phillipsscrewdriver,holesaw •Wirestrippers,“fishtape”,otherelectricaltools •Electricalboxforthermostat: a.Ifyouareconnectingtopowerleadsfromonly1or2floorwarming systems,youmayuseasingle-gang,31⁄2inchdeepbox. b.Ifyouareconnectingtopowerleadsfrom3floorwarmingsystems, usea4x4x21⁄8inchordeeperbox(nota2-gangbox)whenyourwallstuds arestillexposed.Installasingle-gang“mud-ring”coverontheboxbefore installingdrywallmaterials. c.Formorethan3floorwarmingsystemsorotherlayouts,youmayneed toinstallajunctionboxtoconnectthepowerleadstogether.Thenuse housewiretoconnectbetweenthejunctionboxandthethermostat electricalbox.Seetheinstallationinstructionsforyourfloorwarming systemformoreinformation.
ALWAYS:WireallcircuitsasClass1,ElectricLightandPowerCircuits. ALWAYS:Wireallcircuitswithinsulationrated600Vminimum. ALWAYS:Mountthiscontrolonlytoagroundedmetallicboxora nonmetallicbox. ALWAYS:Usepowersupplywiressuitableforatleast90°C. CAUTION:Highvoltage–disconnectpowersupplybeforeservicing. CAUTION:TheGFCIinthiscontroldoesnotprotectagainstshockifboth
bareconductorsaretouchedatthesametime.
5. Thecircuitbreakerinthemaincircuitpanelshouldbe15ampsmaximumforafloorwarmingsystemtotaling12ampsorless.Forlargersystemsupto15amps,usea20ampmaximumcircuitbreaker.Neverexceed15ampsonthisthermostat.Youmayconsiderusinganarc-fault(AFCI)typecircuitbreakerforadditionalprotection.6. Pullthepowersupplywiringintothisbox,leavingabout6inchesofwire.7. Pullthefloorsensorwireandthepowerleadwiresfromyourfloorwarmingsystemupthewall,intothisbox.Refertoyourfloorwarmingsysteminstallationinstructionsforplacementofthefloorsensortipintothefloorarea.Note: The sensor wires should not be run in the same conduit as line voltage wires to avoid possible interference. If the sensor lead wires are not long enough, they may be extended an additional 15 feet (4.5 m) using minimum 20-gage 2-conductor wire or up to 50 feet (15 m) using shielded wire. 8.Mounttheelectricalbox.
powermodule
frontmodule
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Cycle 1 2 3 4Mon-Fri 6:00 am 8:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 F Saturday 7:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 FSunday 7:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 F
U1 (User changeable)
82 F 82 F74 F 74 F
Note: Air Sensing mode default temperatures are 70F and 62F.
Cycle 1 2 3 4Mon-Fri 5:00 am 7:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 F Saturday 5:00 am 9:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 FSunday 5:00 am 9:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 F
P1 (Early Riser)
Note: Air Sensing mode default temperatures are 70F and 62F.
Cycle 1 2 3 4Mon-Fri 5:00 am 8:00 am 6:00 pm 11:00 pm
82 F 74 F 82 F 74 F Saturday 6:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 FSunday 6:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 F
P2 (Longer Day)
Note: Air Sensing mode default temperatures are 70F and 62F.
Cycle 1 2 3 4Mon-Fri 6:00 am 9:00 am 6:00 pm 10:00 pm
75 F 70 F 75 F 70 F Saturday 7:00 am 10:00 am 6:00 pm 10:00 pm
75 F 70 F 75 F 70 FSunday 7:00 am 10:00 am 6:00 pm 10:00 pm
75 F 70 F 75 F 70 F
P4 (Take the chill off)
Note: Air Sensing mode default temperatures are 65F and 60F.
Cycle 1 2 3 4Mon-Fri 6:00 am 8:00 am 6:00 pm 10:00 pm
82 F 79 F 82 F 75 F Saturday 6:00 am 9:00 am 6:00 pm 10:00 pm
82 F 79 F 82 F 75 FSunday 6:00 am 9:00 am 6:00 pm 10:00 pm
82 F 79 F 82 F 75 F
P3 (At home during the day)
Note: Air Sensing mode default temperatures are 70F, 67F, and 62F.
Example
Cycle 1 2 3 4Mon-Fri --:-- 7:30 am 6:00 pm --:--
-- F 72 F 80 F -- F 80 F 80 F
72 F
temperature to make sure it is heating for a few minutes (section 5), c. Test the GFCI (section 5).
5
sensor
2. InstallationRemove the Thermostat Face1.RemovethethermostatFrontModulefromthePowerModulebyopeningthedoorandlooseningthescrew.2. PulloutwardnearthebottomontheFrontModuleandliftoff.
Prepare the Wiring1.Findalocationforyourthermostat.Itissuitableforindooruseonly,oninsulatedoruninsulatedwalls.Locateitabout41⁄2feetto5feetabovetheflooronaninsidewall.Makesureitiswellventilatedandnotlocatedinaconfinedspacesuchasasmallclosetorcabinet.Avoidplacingitnearotherheatsourcessuchashot-waterpiping,heatduct,wall-mountlighting,anddirectsunlighttohelppreventadverselyaffectingthethermostat.2. Turnoffthepowertothefloorwarmingsystematthemaincircuitpanelbeforedoinganyelectricalwork.3. Aqualifiedelectricianshouldrunadedicatedcircuitfromthemaincircuitpaneltothethermostatlocation.4. Ifadedicatedcircuitisnotpossible,youmaytapfromanothercircuitintheroom.Makesurethereisenoughloadcapacity(amps)tohandletheadditionofyourfloorwarmingsystem,andthatitisNOTwiredinserieswithanyotherdevice,includingotherGFCIs.
Owner’s ManualYour new SunStat Pro thermostatisdesignedtocontrolthevoltagetoeithera120VACor240VACresistivefloorwarmingsystem.
Pleasefollowthismanualforcompleteinstallationandoperationinstructions.Ifyouhaveanyquestionsorcomments,trycallingTechnicalSupportat1-888-432-8932.
CAUTION:Makesureyouarequalifiedandarefamiliarwithhousewiring.Thisisalinevoltagedevicethatcouldcauseseriousinjuryordamageifimproperlyinstalled.
Connect Wires1.Matchandconnectthetwowiresmarked“LINE1”and“LINE2”tothepowersupplywiresusingthewirenutsprovided.2. Gentlytugonthewirestomakesuretheyaresecure,otherwiseawirecouldloosenandcausefailure.3. Overwrapthewirenutswithelectricaltapetobettersecurethemtothewires.4.Matchandconnectthetwowiresmarked“LOAD1”and“LOAD2”tothefloorwarmingsystemleadwiresandsecurethesewiresthesameway.5. Connectthehousegroundwiretothegreenorbareleadwire(s)ofyourfloorwarmingsystem.6. Inserttheendsofthefloorsensorwireintothe“SENSOR”terminals(1and2)andtightenthescrews.Thereisnopolarity,soitdoesnotmatterwhichwireendgoesintowhichterminal.
CAUTION:Beforecontinuing,makesureyourpowersupplyvoltagematchesthevoltageratingofyourfloorwarmingsystem.Connecting240Vtoa120Vfloorwarm-ingsystemwillcauseoverheatinganddamagetothesystemandmaydamagethecontrol,otherwiring,floorcoverings,etc.
Remote Control1. Ifyouwanttoconnectyourthermostattoaremotecontroldevice,suchasahomeautomationsystem,firstmakesurethattheremotedevicehasa“drycontact”output(anun-energizedswitch,suchasthecontactsonarelay).Manyhomeautomationsystemscomewithsuchanoutputthatopensorclosesatspecifiedtimes.2. Pull2-conductorwire,size18-to24-gage,throughthewallfromtheremotedevice,intothiselectricalbox.3. Connectthewireendsintothe“SETBACK”terminals(5and6)andtightenthescrews(nopolarity).SunStat Relays1. IfyouwanttouseyourthermostattodriveaSunStatRelay(s)(askyourdealeraboutthisconvenientwaytocontrollargersystemswithonethermostat),firstreadandfollowtheinstructionsfortheSunStatRelaythoroughly.2. Pull2-conductorwire,size18-to24-gage,throughthewallfromtheSunStatRelay,intothiselectricalbox.Thiswiremaybeupto100feet(30m)inlengthfromthethermostattothelastSunStatRelayinstalled.3. Connectthewireendsintothe“RELOUT”terminals(3and4)andtightenthescrews(ObservepolarityofthewireswhenconnectingtotheSunStatRelay).Mount the Thermostat1.Carefullyfoldandpressthewiresbackintotheelectricalbox.Donotusethethermostattopushthemin,asthismaycauseconnectionstoloosenandpossiblefailure.2. SecurethethermostatPowerModuleintotheboxwiththemountingscrewsprovided.3. CarefullysnaptheFrontModuleontothePowerModule.4. Tightenthescrew.5. Switchonthepoweratthemaincircuitpanel.NOTE to contractors:After installing the thermostat, be sure to: a. Do a Quick Setup (section 3), b. Temporarily override the setpoint
SunStatProProgrammableThermostat
Model500670
3. PresstheHOLD/RETURNbuttonorwait15secondsandthethermostatwillreturntothenormaloperatingmode,savingyourselection.ThethermostatwillnowdisplayaP1,P2,P3,orP4atthebottomright.
3. Quick SetupOn/Off SwitchYourthermostatshouldbeturnedoffwhenitisfirstinstalled.ThedisplaywillshowOFFandthetimeandday.1.Slidetheon/offswitchtotheupperposition,turningthethermostaton.Thedisplaywillshowthetimeandday,temperatures,andotherinformation.2. Toturnthethermostatoffanytime,slidetheon/offswitchtothelowerposition.Noheatingwilloccurandallprogrammingisretained.
Change Format Between °F / 12-hour and °C / 24-hourYourthermostatisfactorysettooperateineither°F/12hourformator°C/24hour(militarytime)format.Ifneeded,youmaychangethisatanytimeasfollows:1.PresstheOPTIONSbuttonandholdfor1second.An°Fand12hwillshowonthedisplay.2. Pressthedownorupbuttontotoggleto°Cand24h.3. PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
Set the Current Time and Day1.PresstheDAY/TIMEbuttonandholdfor1second.Thehourshouldbeblinking.2. Pressthedownorupbuttontoadjustthehour.3. PresstheDAY/TIMEbuttonbriefly.Theminutesshouldbeblinking.4. Pressthedownorupbuttontoadjusttheminutes.5. PresstheDAY/TIMEbuttonbriefly.Thedayshouldbeblinking.6. Pressthedownorupbuttontoadjusttheday.7. PresstheHOLD/RETURNbuttonorwait15secondsandthethermostatwillreturntothenormaloperatingmode,savingyoursettings.
MO
SET TEMP
FLOORCYCLE
MA
°F
1-4
Customized Program Schedule (User)Tocustomizetheprogramsheduletomeetyourneeds,followthesesteps:
1.PressthePROGRAMbuttonandholdfor1second.ProandU1, P1, P2, P3, or P4willshowonthedisplay.2.PressthedownorupbuttontoselectU1.3.PressthePROGRAMbuttonbriefly.CYCLE 1andMOthroughFRwillshowonthedisplay.Thehourshouldbeblinking.4.Pressthedownorupbuttontoadjustthehour.5.PressthePROGRAMbuttonbriefly.Theminutesshouldbeblinking.6.Pressthedownorupbuttontoadjusttheminutes.7.PressthePROGRAMbuttonbriefly.Thesetpointtemperatureshouldbeblinking.8.Pressthedownorupbuttontoadjustthesetpointtemperature. Note: A good rule of thumb is to adjust this about 5 to 8°F (3 to 5 °C) lower during cycles when you are away to help reduce energy use. If you set the “away” cycles too low, it will take much longer to raise the temperature again and may result in unsatisfying performance. Note: Some wood and laminate floor manufacturers recommend a maximum of 82 to 84°F (27° to 28°C). Check with manufacturer.9.PressthePROGRAMbuttonbrieflytomovetothenextcyclenumber.10. RepeatSteps3through7toadjusttheremainingcycletimesandsetpointtemperaturesMOthroughFR,andfortheotherdaysoftheweek.11.Whenyoufinish,oratanytimeduringtheseadjustments,presstheHOLD/RETURNbuttonorwait30secondsandthethermostatwillreturntothenormaloperatingmode.Youradjustmentswillbesaved.
Note: The display in normal operating mode will not show a “U1” indicating “User” schedule. Also, all schedule adjustments are saved in memory and will not be lost during power failure.
Note: If you only want to use two cycles during a day, clear the other cycles by reducing their temperature below 40°F (4.5°C) to show (---). To use these cycles again, adjust their time and temperature.
frompowersupply
on/off
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Use the Factory Programmed “User” ScheduleIfyouwanttobeginusingyourthermostatnowwithoutmakinganychangestothefactorysetprogrammingschedule,youmayskiptosection“5 Operation”.Itwilloperateinthe“User”Schedule(U1),pre-programmedasfollows,andcanbecustomizedlatertoyourneeds(seesection“4 Additional Setups”):
4. Additional SetupsLifestyle Program Schedules (Presets)Thereareconvenientschedulesalreadysetuptomeettypicallifestyles.IfyouseeascheduleP1throughP4youlike,selectoneasfollows:
1.PressthePROGRAMbuttonandholdfor1second.ProandU1, P1, P2, P3, or P4willshowonthedisplay.2. PressthedownorupbuttonbrieflytoselectP1,P2,P3,orP4.Theseschedulesarenotabletobemodified,andareasfollows:
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
tofloorwarmingsystem
1. Preparation1.Unpackyourthermostatandmakesureeverythingisingoodcondition:•Thermostat•Floor sensor•Small screwdriver•Mounting screws•Wire nuts for wiring connectionsIfanypartsaremissingordamaged,contactthestorewhereyoupurchasedthisthermostat.Donotinstalladamagedpart.
2. Gatherthefollowingtoolsandsupplies: •Phillipsscrewdriver,holesaw •Wirestrippers,“fishtape”,otherelectricaltools •Electricalboxforthermostat: a.Ifyouareconnectingtopowerleadsfromonly1or2floorwarming systems,youmayuseasingle-gang,31⁄2inchdeepbox. b.Ifyouareconnectingtopowerleadsfrom3floorwarmingsystems, usea4x4x21⁄8inchordeeperbox(nota2-gangbox)whenyourwallstuds arestillexposed.Installasingle-gang“mud-ring”coverontheboxbefore installingdrywallmaterials. c.Formorethan3floorwarmingsystemsorotherlayouts,youmayneed toinstallajunctionboxtoconnectthepowerleadstogether.Thenuse housewiretoconnectbetweenthejunctionboxandthethermostat electricalbox.Seetheinstallationinstructionsforyourfloorwarming systemformoreinformation.
ALWAYS:WireallcircuitsasClass1,ElectricLightandPowerCircuits. ALWAYS:Wireallcircuitswithinsulationrated600Vminimum. ALWAYS:Mountthiscontrolonlytoagroundedmetallicboxora nonmetallicbox. ALWAYS:Usepowersupplywiressuitableforatleast90°C. CAUTION:Highvoltage–disconnectpowersupplybeforeservicing. CAUTION:TheGFCIinthiscontroldoesnotprotectagainstshockifboth
bareconductorsaretouchedatthesametime.
5. Thecircuitbreakerinthemaincircuitpanelshouldbe15ampsmaximumforafloorwarmingsystemtotaling12ampsorless.Forlargersystemsupto15amps,usea20ampmaximumcircuitbreaker.Neverexceed15ampsonthisthermostat.Youmayconsiderusinganarc-fault(AFCI)typecircuitbreakerforadditionalprotection.6. Pullthepowersupplywiringintothisbox,leavingabout6inchesofwire.7. Pullthefloorsensorwireandthepowerleadwiresfromyourfloorwarmingsystemupthewall,intothisbox.Refertoyourfloorwarmingsysteminstallationinstructionsforplacementofthefloorsensortipintothefloorarea.Note: The sensor wires should not be run in the same conduit as line voltage wires to avoid possible interference. If the sensor lead wires are not long enough, they may be extended an additional 15 feet (4.5 m) using minimum 20-gage 2-conductor wire or up to 50 feet (15 m) using shielded wire. 8.Mounttheelectricalbox.
powermodule
frontmodule
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Cycle 1 2 3 4Mon-Fri 6:00 am 8:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 F Saturday 7:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 FSunday 7:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 F
U1 (User changeable)
82 F 82 F74 F 74 F
Note: Air Sensing mode default temperatures are 70F and 62F.
Cycle 1 2 3 4Mon-Fri 5:00 am 7:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 F Saturday 5:00 am 9:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 FSunday 5:00 am 9:00 am 5:00 pm 10:00 pm
82 F 74 F 82 F 74 F
P1 (Early Riser)
Note: Air Sensing mode default temperatures are 70F and 62F.
Cycle 1 2 3 4Mon-Fri 5:00 am 8:00 am 6:00 pm 11:00 pm
82 F 74 F 82 F 74 F Saturday 6:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 FSunday 6:00 am 9:00 am 5:00 pm 11:00 pm
82 F 74 F 82 F 74 F
P2 (Longer Day)
Note: Air Sensing mode default temperatures are 70F and 62F.
Cycle 1 2 3 4Mon-Fri 6:00 am 9:00 am 6:00 pm 10:00 pm
75 F 70 F 75 F 70 F Saturday 7:00 am 10:00 am 6:00 pm 10:00 pm
75 F 70 F 75 F 70 FSunday 7:00 am 10:00 am 6:00 pm 10:00 pm
75 F 70 F 75 F 70 F
P4 (Take the chill off)
Note: Air Sensing mode default temperatures are 65F and 60F.
Cycle 1 2 3 4Mon-Fri 6:00 am 8:00 am 6:00 pm 10:00 pm
82 F 79 F 82 F 75 F Saturday 6:00 am 9:00 am 6:00 pm 10:00 pm
82 F 79 F 82 F 75 FSunday 6:00 am 9:00 am 6:00 pm 10:00 pm
82 F 79 F 82 F 75 F
P3 (At home during the day)
Note: Air Sensing mode default temperatures are 70F, 67F, and 62F.
Example
Cycle 1 2 3 4Mon-Fri --:-- 7:30 am 6:00 pm --:--
-- F 72 F 80 F -- F 80 F 80 F
72 F
temperature to make sure it is heating for a few minutes (section 5), c. Test the GFCI (section 5).
Lockout FeatureYourthermostathastheabilitytolockoutadjustmentbyotherusers.Thismaybeusefulinpubliclocations.Onlytheon/offswitchandtheGFCItestbuttonwillthenoperate.
1.Pressthedownandupbuttonatthesametimeandholdfor1second.LOCKwillshowonthedisplay.2. Tocancelthislockout,thedownandupbuttonmustbepressedandheldfor1second.Thethermostatwillreturntothenormaloperatingmode.
Test the GFCIThereisaGFCI(GroundFaultCircuitInterrupter)insidethethermostat.Itisdesignedtohelpprotectpeoplefrompossibleelectricalshockifthefloorwarmingsystemhasbeendamaged.
TomakesuretheGFCIisoperating,testitafteritisinstalledandonceeachmonth:
1.MakesurethethermostatisHEATING.Youmayneedtoincreasethesetpointtemporarily.2. PresstheGFCITestbuttononthesideofthethermostat.GFCI TRIPshouldshowonthedisplayandaredlightwillshownexttotheGFCITestbutton.Youshouldalsohearaclick,indicatingpowerhasbeenremovedfromthefloorwarmingsystem.Ifanyoftheseindicatorsfail,turnoffthethermostatandreplaceit.Donotcontinuetouse.3. ToresettheGFCI,slidetheOn/Offswitchoffandbackon.IftheGFCIdoesnotreset,turnthethermostatoffandgotosection6 “Troubleshooting” forhelp.
Limited WarrantyWattsRadiant,Inc.warrantsthisthermostatcontrolandsensor(theproduct)tobefreefromdefectsinmaterialandworkmanshipforaperiodoftwo(2)yearsfromthedateoforiginalpurchasefromauthorizeddealers.Duringthisperiod,WattsRadiant,Inc.willreplacetheproductorrefundtheoriginalcostoftheproductatWattsRadiant’soption,withoutcharge,iftheproductisprovendefectiveinnormaluse.Pleasereturnthethermostattoyourdistributortobeginthewarrantyprocess.Thislimitedwarrantydoesnotcovershippingcosts.Nordoesitcoveraproductsubjectedtomisuseoraccidentaldamage.Thiswarrantydoesnotcoverthecostofinstallation,diagnosis,removalorreinstallation,oranymaterialcostsorlossofuse.Thislimitedwarrantyisinlieuofallotherwarranties,obligations,orliabilitiesexpressedorimpliedbythecompany.InnoeventshallWattsRadiant,Inc.beliableforconsequentialorincidentaldamagesresultingfrominstallationofthisproduct.Somestatesorprovincesdonotallowlimitationsonhowlonganimpliedwarrantylasts,ortheexclusionorlimitationofincidentalorconsequentialdamages,sotheaboveexclusionsorlimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrightsandyoumayalsohaveotherrightsthatvaryfromstatetostate.
5. OperationControlling the TemperatureYourthermostathasseveralwaystocontrolyourfloorwarmingsystem.Itisfactorysettooperateintheprogramscheduleselectedbutthiscanbeoverriddentomeetyourneeds.
Program ScheduleThethermostatwilloperatenormallyintheprogramscheduleselected.
Whenheatiscalledfor,HEATINGwillshowonthedisplayandfullpowerissuppliedtothefloorwarmingsystem.ThisalsosignalstoturnonanySunStatRelaysthatmaybeconnectedtoyourthermostat.
7. Specifications PowerSupply 120/240VAC,50/60Hz MaximumLoad 15amps,resistive MaximumPower 1800wattsat120VAC 3600wattsat240VAC GFCI ClassA(5milliamptrip) DisplayRange 32°Fto140°F(0°Cto60°C) SettingRange 40°Fto99°F(4°Cto37°C) Accuracy ±0.9°F(0.5°C) StorageTemp 0°Fto120°F(0°Cto49°C) Sensor Thermistor,10kNTC,double-insulated Memory Programmingretainedindefinitely Currenttimeanddaywillneedre-set ifpowerislostmorethan30minutes. ETLListing ControlNo.3037530 ConformstoUL873,UL943,CSAC22.2No.
24,andCAN/CSAC22.2No.144
6. TroubleshootingProblem Solution
Thermostatworksbutnoheatfromthesystem.
1.Checkwiringconnections.2.IfGFCIistripped,resetthermostatwithon/offswitch.3.Checkresistancesonfloorwarmingsystem.Seemanualforsystem.
Nodisplay.1.Checkwiringconnections.2.Checkcircuitbreakerorotherprotection“upstream”ofthermostat.
GFCIistripped.1.Checkwiringconnections.2.Resetthermostatbyswitchingoff/on.3.Checkresistancesonfloorwarmingsystem.Seemanualforsystem.
Heatingoccursatwrongtimes.
1.CheckthatthecurrenttimeandscheduletimesareproperlysettoAMorPM.2.OnuninsulatedconcreteSmartStartmaystartheatingveryearly.Youmayturnthisfeatureoffifnotdesired.
Er1(onlyatstartup) Floorsensornotcorrecttypeoroutofrange.Checkfloorsensorresistance.
Er2 Floorsensorshort-circuited.Turnoffpoweratbreakerandreplacesensor.OrResetFactoryDefaults(section4).
Er3Floorsensornotattachedandthermostatinfloorsensemode.Turnoffpoweratbreakerandattachsensor.OrResetFactoryDefaults(section4).
Er4orEr5 Internalairsensorisfaulty.Replacethermostatoroperateinfloorsensemode.
Er6Internaltemperatureoverlimit.Makesuresunlightisnotdirectedatthethermostatorotherheatsourceinproximity.Otherwise,Turnoffpoweratbreakerandcontactfactory.
Er7“End-of-life”indication.GFCIwillnolongerfunctioncorrectlyorsafely.Resetthecircuitbreakerorreplacethermostat.
Temporarily Overriding the Temperature
Youcantemporarilyadjustthetemperaturesetpointasfollows.Thiswillholduntilthenextscheduledprogramtime:
1.Pressthedownoruparrowbuttonandholdfor1secondtoadjustthesetpointtemperature.2.Wait5secondsandthethermostatwillreturntothenormaloperatingmode,savingyouradjustment.3. Tocancelthistemporaryoverrideandreturntothenormalscheduletemperature,presstheHOLD/RETURNbuttonbriefly.
Hold a Selected Temperature
Youcanholdthecurrentsetpointtemperatureindefinitely,especiallyusefulwhenyouareonvacation.
1.PresstheHOLD/RETURNbuttonandholdfor1second.HOLDwillshowonthedisplayandthesetpointtemperatureshownwillbemaintaineduntilyoucancelthishold.2. Tocancelthishold,presstheHOLD/RETURNbuttonandholdfor1second.HOLDwilldisappearfromthedisplay.3. PressHold/Returnbrieflyandthethermostatwillreturntothenormalscheduletemperature.
Setback
YoucanusetheSetbackbuttontooverridethecurrentsetpointtemperature.Thisisespeciallyusefulifyouhaveanalternatetemperatureyourepeatedlyselectwhenyouareaway.
1.PresstheSETBACKbuttonbriefly.SETBACKwillshowonthedisplayanditstemperature.Thissetpointwillholduntilthenextscheduledprogramtime.2. ToholdthisSetbacktemperatureindefinitely,presstheHOLD/RETURNbuttonandholdfor1second.Tocancelthishold,presstheHOLD/RETURNbuttonagainandholdfor1second.3. TocancelthisSetbacktemperatureandreturntothenormalscheduletemperature,presstheSETBACKbuttonbriefly.
To change the temperature stored in the SETBACK button:
1.PresstheSETBACKbuttonandholdfor1second.SETBACKwillshowonthedisplayanditstemperatureshouldbeblinking.2. Pressthedownorupbuttontoadjustthetemperature.3. PresstheHOLD/RETURNbuttonorwait5secondsandthethermostatwillreturntothenormaloperatingmode,savingyouradjustment.
Remote Control Override
IfyourthermostatwasinstalledwithRemoteControlinputfromahomeautomationsystem(seesection2 “Installation”),thiswilloverridethethermostatwhentheremotecontrolsystemclosesitsoutputswitchorrelay.SETBACKandHOLDwillshowonthedisplayanditwilloperateintheSetbacktemperatureindefinitely.Tocancelthis,theRemoteControlswitchorrelaymustbeopened.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
UsageYourthermostatstoresinmemorythenumberofhoursitisheating.Thisinformationmaybeusefulincalculatingtheenergyusedbyyourfloorwarmingsystem.
1.PresstheOPTIONSbuttonandholdfor1second.2. PresstheOPTIONSbuttonagainuntilUSAGEand1 dshowsonthedisplay.3. Thetimeshownonthedisplayisthenumberofhoursitwasheatingtoday.4. Pressthedownorupbuttontotogglebetweentheprevious1-day,7-day,and30-dayusages.5. PresstheHOLD/RETURNbuttonorwait15secondsandthethermostatwillreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Air Sensing and Regulator ModesYourthermostatisfactorysettooperatebasedonthefloorsensortemperature.Thisistherecommendedmethodtoproperlycontrolyourfloorwarmingsystem.
However,itisalsopossibletoalsooperateyourthermostatineithertheairsensingmodeorregulatormodetemporarilyifthefloorsensorwasdamagedornotinstalled.AnewfloorsensorshouldbeinstalledtoenableoperationinFloorSenseModeassoonaspossible.Thesemodesmustbeusedwithcautiontoavoidoverheatingthefloor.•AirSensingMode–Thismodeoperatesbyanairsensorinsidethethermostat.Ifyourfloorsensorisconnected,youmustsetaFloorLimittemperaturetoavoidoverheatingthefloorcoverings(seeFloor Limitbelow).Note:the internal heating in the thermostat may affect the sensor temperature.•RegulatorMode–Inthismodetheuserselectstheamountoftimethefloorwarmingsystemheatsduringa15-minuterepeatingcycle.Thereisnotemperaturesensinginthismode.(seesection5 “Operation”)
Ifyouwantittooperateintheairsensingmodeorregulatormode,youmaychangethisasfollows:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilSENSshowsonthedisplay.3.PressthedownorupbuttontotogglethistoAirorrEGu.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
Floor LimitIfyousetyourthermostattooperateinAirSenseMode,thedisplaywillshowtheairtemperaturebutwillalsomonitorthefloorsensorifitisconnected.
Toavoidpossiblyoverheatingyourfloor,youmustsetaFloorLimittemperaturesoitturnsoffthesystemifthefloorsensortemperatureexceedsthisFloorLimit.Somewoodandlaminatefloormanufacturersrecommendamaximumof82to84°F(27°to28°C).Checkwithmanufacturer.Itisfactorysetto99F(37C)andcanbeadjustedasfollows:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilSET TEMPandFLOOR LIMITshowsonthedisplaywiththecurrentFloorLimittemperature.3.Pressthedownorupbuttontoadjustthis.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
CalibrationYourthermostatallowstheabilitytoslightlyadjustthedisplaytemperature.Normallythisisnotrecommendednorrequired.However,inspecialcircumstancesthismaybenecessary,andcanbedoneasfollows:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilCALshowsonthedisplaywiththecurrentsensortemperatureandthecurrentoffsetvalue.Theoffsetvalueisfactorysettozero.3.Pressthedownorupbuttontoadjustthis.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Resetting Factory DefaultsYourthermostathastheabilitytoresetallprogramming,settings,andusagetimestothefactorydefaults.Ifyouarecertainyouwanttodothis:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilthesoftwareversionSoft 1.4orsimilarshowsonthedisplay.3.Pressthedownandupbuttonsatthesametimeandholdfor1second.Doneandrstwillshowonthedisplay.Thethermostatwillgothroughastartupmodeandreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
SmartStartYourthermostatisfactorysetwiththe“SmartStart”featureturnedon.Thethermostatautomaticallydeterminesthebesttimetobeginheatingsoitreachesyoursetpointtemperatureatthescheduledtime.
Ifthisfeatureisnotdesired,youmayturnitoff:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilSStshowsonthedisplay.3.PressthedownorupbuttontotogglethisOnorOff.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Regulator Mode
Ifyousetyourthermostattooperateintheregulatormode,itwilloperatelikeatimer.Youmayadjusttheamountoftimethefloorwarmingsystemheatsduringa15-minuterepeatingcycleasfollows:
1.Withthethermostatintheregulatormode,itwillshowtheheatingtimeandthecurrentcycletime.2. Pressthedownorupbuttontoadjusttheheatingtimefrom0through15.•Example:Avalueof6willcauseittoheatfor6minutesof the15minutecycle,andthennotheatfor9minutesofthe15 minutecycle.•Zerowillcauseittoneverheat.•15willcauseittoheatcontinuously.3. Thecycletimeshownatthebottomofthedisplayisthecurrenttimeinthe15-minutecycle.Itrepeatsfrom0:00through14:59(min:sec).
PPLIMP08001 IND © 2007-2010
WR_SunStat_Manual_Programmable EN 20100209 Effective: 02/09/2010
Lockout FeatureYourthermostathastheabilitytolockoutadjustmentbyotherusers.Thismaybeusefulinpubliclocations.Onlytheon/offswitchandtheGFCItestbuttonwillthenoperate.
1.Pressthedownandupbuttonatthesametimeandholdfor1second.LOCKwillshowonthedisplay.2. Tocancelthislockout,thedownandupbuttonmustbepressedandheldfor1second.Thethermostatwillreturntothenormaloperatingmode.
Test the GFCIThereisaGFCI(GroundFaultCircuitInterrupter)insidethethermostat.Itisdesignedtohelpprotectpeoplefrompossibleelectricalshockifthefloorwarmingsystemhasbeendamaged.
TomakesuretheGFCIisoperating,testitafteritisinstalledandonceeachmonth:
1.MakesurethethermostatisHEATING.Youmayneedtoincreasethesetpointtemporarily.2. PresstheGFCITestbuttononthesideofthethermostat.GFCI TRIPshouldshowonthedisplayandaredlightwillshownexttotheGFCITestbutton.Youshouldalsohearaclick,indicatingpowerhasbeenremovedfromthefloorwarmingsystem.Ifanyoftheseindicatorsfail,turnoffthethermostatandreplaceit.Donotcontinuetouse.3. ToresettheGFCI,slidetheOn/Offswitchoffandbackon.IftheGFCIdoesnotreset,turnthethermostatoffandgotosection6 “Troubleshooting” forhelp.
Limited WarrantyWattsRadiant,Inc.warrantsthisthermostatcontrolandsensor(theproduct)tobefreefromdefectsinmaterialandworkmanshipforaperiodoftwo(2)yearsfromthedateoforiginalpurchasefromauthorizeddealers.Duringthisperiod,WattsRadiant,Inc.willreplacetheproductorrefundtheoriginalcostoftheproductatWattsRadiant’soption,withoutcharge,iftheproductisprovendefectiveinnormaluse.Pleasereturnthethermostattoyourdistributortobeginthewarrantyprocess.Thislimitedwarrantydoesnotcovershippingcosts.Nordoesitcoveraproductsubjectedtomisuseoraccidentaldamage.Thiswarrantydoesnotcoverthecostofinstallation,diagnosis,removalorreinstallation,oranymaterialcostsorlossofuse.Thislimitedwarrantyisinlieuofallotherwarranties,obligations,orliabilitiesexpressedorimpliedbythecompany.InnoeventshallWattsRadiant,Inc.beliableforconsequentialorincidentaldamagesresultingfrominstallationofthisproduct.Somestatesorprovincesdonotallowlimitationsonhowlonganimpliedwarrantylasts,ortheexclusionorlimitationofincidentalorconsequentialdamages,sotheaboveexclusionsorlimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrightsandyoumayalsohaveotherrightsthatvaryfromstatetostate.
5. OperationControlling the TemperatureYourthermostathasseveralwaystocontrolyourfloorwarmingsystem.Itisfactorysettooperateintheprogramscheduleselectedbutthiscanbeoverriddentomeetyourneeds.
Program ScheduleThethermostatwilloperatenormallyintheprogramscheduleselected.
Whenheatiscalledfor,HEATINGwillshowonthedisplayandfullpowerissuppliedtothefloorwarmingsystem.ThisalsosignalstoturnonanySunStatRelaysthatmaybeconnectedtoyourthermostat.
7. Specifications PowerSupply 120/240VAC,50/60Hz MaximumLoad 15amps,resistive MaximumPower 1800wattsat120VAC 3600wattsat240VAC GFCI ClassA(5milliamptrip) DisplayRange 32°Fto140°F(0°Cto60°C) SettingRange 40°Fto99°F(4°Cto37°C) Accuracy ±0.9°F(0.5°C) StorageTemp 0°Fto120°F(0°Cto49°C) Sensor Thermistor,10kNTC,double-insulated Memory Programmingretainedindefinitely Currenttimeanddaywillneedre-set ifpowerislostmorethan30minutes. ETLListing ControlNo.3037530 ConformstoUL873,UL943,CSAC22.2No.
24,andCAN/CSAC22.2No.144
6. TroubleshootingProblem Solution
Thermostatworksbutnoheatfromthesystem.
1.Checkwiringconnections.2.IfGFCIistripped,resetthermostatwithon/offswitch.3.Checkresistancesonfloorwarmingsystem.Seemanualforsystem.
Nodisplay.1.Checkwiringconnections.2.Checkcircuitbreakerorotherprotection“upstream”ofthermostat.
GFCIistripped.1.Checkwiringconnections.2.Resetthermostatbyswitchingoff/on.3.Checkresistancesonfloorwarmingsystem.Seemanualforsystem.
Heatingoccursatwrongtimes.
1.CheckthatthecurrenttimeandscheduletimesareproperlysettoAMorPM.2.OnuninsulatedconcreteSmartStartmaystartheatingveryearly.Youmayturnthisfeatureoffifnotdesired.
Er1(onlyatstartup) Floorsensornotcorrecttypeoroutofrange.Checkfloorsensorresistance.
Er2 Floorsensorshort-circuited.Turnoffpoweratbreakerandreplacesensor.OrResetFactoryDefaults(section4).
Er3Floorsensornotattachedandthermostatinfloorsensemode.Turnoffpoweratbreakerandattachsensor.OrResetFactoryDefaults(section4).
Er4orEr5 Internalairsensorisfaulty.Replacethermostatoroperateinfloorsensemode.
Er6Internaltemperatureoverlimit.Makesuresunlightisnotdirectedatthethermostatorotherheatsourceinproximity.Otherwise,Turnoffpoweratbreakerandcontactfactory.
Er7“End-of-life”indication.GFCIwillnolongerfunctioncorrectlyorsafely.Resetthecircuitbreakerorreplacethermostat.
Temporarily Overriding the Temperature
Youcantemporarilyadjustthetemperaturesetpointasfollows.Thiswillholduntilthenextscheduledprogramtime:
1.Pressthedownoruparrowbuttonandholdfor1secondtoadjustthesetpointtemperature.2.Wait5secondsandthethermostatwillreturntothenormaloperatingmode,savingyouradjustment.3. Tocancelthistemporaryoverrideandreturntothenormalscheduletemperature,presstheHOLD/RETURNbuttonbriefly.
Hold a Selected Temperature
Youcanholdthecurrentsetpointtemperatureindefinitely,especiallyusefulwhenyouareonvacation.
1.PresstheHOLD/RETURNbuttonandholdfor1second.HOLDwillshowonthedisplayandthesetpointtemperatureshownwillbemaintaineduntilyoucancelthishold.2. Tocancelthishold,presstheHOLD/RETURNbuttonandholdfor1second.HOLDwilldisappearfromthedisplay.3. PressHold/Returnbrieflyandthethermostatwillreturntothenormalscheduletemperature.
Setback
YoucanusetheSetbackbuttontooverridethecurrentsetpointtemperature.Thisisespeciallyusefulifyouhaveanalternatetemperatureyourepeatedlyselectwhenyouareaway.
1.PresstheSETBACKbuttonbriefly.SETBACKwillshowonthedisplayanditstemperature.Thissetpointwillholduntilthenextscheduledprogramtime.2. ToholdthisSetbacktemperatureindefinitely,presstheHOLD/RETURNbuttonandholdfor1second.Tocancelthishold,presstheHOLD/RETURNbuttonagainandholdfor1second.3. TocancelthisSetbacktemperatureandreturntothenormalscheduletemperature,presstheSETBACKbuttonbriefly.
To change the temperature stored in the SETBACK button:
1.PresstheSETBACKbuttonandholdfor1second.SETBACKwillshowonthedisplayanditstemperatureshouldbeblinking.2. Pressthedownorupbuttontoadjustthetemperature.3. PresstheHOLD/RETURNbuttonorwait5secondsandthethermostatwillreturntothenormaloperatingmode,savingyouradjustment.
Remote Control Override
IfyourthermostatwasinstalledwithRemoteControlinputfromahomeautomationsystem(seesection2 “Installation”),thiswilloverridethethermostatwhentheremotecontrolsystemclosesitsoutputswitchorrelay.SETBACKandHOLDwillshowonthedisplayanditwilloperateintheSetbacktemperatureindefinitely.Tocancelthis,theRemoteControlswitchorrelaymustbeopened.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
UsageYourthermostatstoresinmemorythenumberofhoursitisheating.Thisinformationmaybeusefulincalculatingtheenergyusedbyyourfloorwarmingsystem.
1.PresstheOPTIONSbuttonandholdfor1second.2. PresstheOPTIONSbuttonagainuntilUSAGEand1 dshowsonthedisplay.3. Thetimeshownonthedisplayisthenumberofhoursitwasheatingtoday.4. Pressthedownorupbuttontotogglebetweentheprevious1-day,7-day,and30-dayusages.5. PresstheHOLD/RETURNbuttonorwait15secondsandthethermostatwillreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Air Sensing and Regulator ModesYourthermostatisfactorysettooperatebasedonthefloorsensortemperature.Thisistherecommendedmethodtoproperlycontrolyourfloorwarmingsystem.
However,itisalsopossibletoalsooperateyourthermostatineithertheairsensingmodeorregulatormodetemporarilyifthefloorsensorwasdamagedornotinstalled.AnewfloorsensorshouldbeinstalledtoenableoperationinFloorSenseModeassoonaspossible.Thesemodesmustbeusedwithcautiontoavoidoverheatingthefloor.•AirSensingMode–Thismodeoperatesbyanairsensorinsidethethermostat.Ifyourfloorsensorisconnected,youmustsetaFloorLimittemperaturetoavoidoverheatingthefloorcoverings(seeFloor Limitbelow).Note:the internal heating in the thermostat may affect the sensor temperature.•RegulatorMode–Inthismodetheuserselectstheamountoftimethefloorwarmingsystemheatsduringa15-minuterepeatingcycle.Thereisnotemperaturesensinginthismode.(seesection5 “Operation”)
Ifyouwantittooperateintheairsensingmodeorregulatormode,youmaychangethisasfollows:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilSENSshowsonthedisplay.3.PressthedownorupbuttontotogglethistoAirorrEGu.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
Floor LimitIfyousetyourthermostattooperateinAirSenseMode,thedisplaywillshowtheairtemperaturebutwillalsomonitorthefloorsensorifitisconnected.
Toavoidpossiblyoverheatingyourfloor,youmustsetaFloorLimittemperaturesoitturnsoffthesystemifthefloorsensortemperatureexceedsthisFloorLimit.Somewoodandlaminatefloormanufacturersrecommendamaximumof82to84°F(27°to28°C).Checkwithmanufacturer.Itisfactorysetto99F(37C)andcanbeadjustedasfollows:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilSET TEMPandFLOOR LIMITshowsonthedisplaywiththecurrentFloorLimittemperature.3.Pressthedownorupbuttontoadjustthis.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
CalibrationYourthermostatallowstheabilitytoslightlyadjustthedisplaytemperature.Normallythisisnotrecommendednorrequired.However,inspecialcircumstancesthismaybenecessary,andcanbedoneasfollows:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilCALshowsonthedisplaywiththecurrentsensortemperatureandthecurrentoffsetvalue.Theoffsetvalueisfactorysettozero.3.Pressthedownorupbuttontoadjustthis.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Resetting Factory DefaultsYourthermostathastheabilitytoresetallprogramming,settings,andusagetimestothefactorydefaults.Ifyouarecertainyouwanttodothis:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilthesoftwareversionSoft 1.4orsimilarshowsonthedisplay.3.Pressthedownandupbuttonsatthesametimeandholdfor1second.Doneandrstwillshowonthedisplay.Thethermostatwillgothroughastartupmodeandreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
SmartStartYourthermostatisfactorysetwiththe“SmartStart”featureturnedon.Thethermostatautomaticallydeterminesthebesttimetobeginheatingsoitreachesyoursetpointtemperatureatthescheduledtime.
Ifthisfeatureisnotdesired,youmayturnitoff:
1.PresstheOPTIONSbuttonandholdfor1second.2.PresstheOPTIONSbuttonagainuntilSStshowsonthedisplay.3.PressthedownorupbuttontotogglethisOnorOff.4.PresstheHOLD/RETURNbuttontoreturntothenormaloperatingmode.
MO
MA
SET TEMP
LIMITFLOOR
°F
MO
°C
AIR
SET TEMP
SET BACK
LIMITFLOOR
USAGE
CYCLE
MAMP
MAMP
°C
°F
°C
°F
TU WE TH FR SA SU
HOLD
GFCITRIP
HEATING
°F
P1P2P3P4
LOCK
MO
MA
HEATING
MO
SET TEMP
CYCLE
MA
°F
HOLD
USAGE
MO
CYCLE
MA
°F
TU WE TH FR MO
CYCLE
MA
°F
SET BACK
FLOOR
FLOOR
MO
CYCLE
MA
°F
FLOOR
Regulator Mode
Ifyousetyourthermostattooperateintheregulatormode,itwilloperatelikeatimer.Youmayadjusttheamountoftimethefloorwarmingsystemheatsduringa15-minuterepeatingcycleasfollows:
1.Withthethermostatintheregulatormode,itwillshowtheheatingtimeandthecurrentcycletime.2. Pressthedownorupbuttontoadjusttheheatingtimefrom0through15.•Example:Avalueof6willcauseittoheatfor6minutesof the15minutecycle,andthennotheatfor9minutesofthe15 minutecycle.•Zerowillcauseittoneverheat.•15willcauseittoheatcontinuously.3. Thecycletimeshownatthebottomofthedisplayisthecurrenttimeinthe15-minutecycle.Itrepeatsfrom0:00through14:59(min:sec).