Suction Filter Hydac
-
Upload
mauricio-deleon -
Category
Documents
-
view
222 -
download
2
description
Transcript of Suction Filter Hydac
-
Suction FilterElement
E 7.
402.
7/02
.04
-
2E 7.
402.
7/02
.04
1. DESCRIPTIONSuction filter elements aredesigned to be fitted into thesuction lines of pumps.It is important to ensure thatthe suction filter elements arealways fitted well below theminimum oil level. The standardfiltration rating is 125 micron.In order to avoid suctionproblems caused bycontaminated elements or coldstarts, the suction filter elementscan also be supplied with bypassvalves.The cracking pressure of thebypass valve is 0.2 bar.
Materials:Filter mesh: stainless steelEnd caps: polyamideSupport tube: sheet steel,
zinc-plated
with bypass valve
without bypass valve
3. MODEL CODE 0050 S 125 W / -B0.2(also order example)
Size00150025005001000180
Type of elementS suction filter element
Filtration rating075125
Filter materialW wire mesh
Supplementary detailsno details = without bypass valve (standard)B0.2 = bypass valve with a cracking pressure of 0.2 bar
2. HYDRAULIC SYMBOLS 4. HYDRAULIC DETAILSp-Q curves to ISO 3968, p at 30 mm/s
p in
bar
Q in l/min
-
3E 7.
402.
7/02
.04
5. DIMENSIONS 6. NOTEThe information in this brochurerelates to the operating conditionsand applications described.For applications or operatingconditions not described, pleasecontact the relevant technicaldepartment.Subject to technical modifications.
Type A B C D E SW Flow rate Filtration(ISO 228) l/min area cm
0015 S 44 104 G 1/2 24 10.5 30 15 3000025 S 63 127 G 3/4 36 13.5 46 25 5500050 S 63 159 G 1 36 13.5 46 50 7200100 S 86 210 G 1 1/2 46 13.5 69 100 13700180 S 86.5 311 G 2 46 13.5 69 180 2110
bypass valve