Status of the Muon Alignment System Muon Alignment Group Muon IB December 11th, 2012.
Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs
description
Transcript of Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs
![Page 1: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/1.jpg)
Study of the Spatial Resolution and Muon Tomographic Imaging Properties of
Glass RPCs
Qite Li
Peking University
![Page 2: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/2.jpg)
Knowledge is PowerSir Francis Bacon (1561-1626)
![Page 3: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/3.jpg)
Nuclear Knowledge can be the Power of
• Peace• Happiness
• Fear• Frustration
![Page 4: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/4.jpg)
●Uranium 90% (HEU)●Pu-239 93% (WGPu)
●26 kg HEU / 5kg WGPu ●11 cm / 6 cm box
![Page 5: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/5.jpg)
![Page 6: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/6.jpg)
Muon Tomography(MT)
2.3mrad 10mrad 20mrad ~1.1°
~GeV Muon 1/cm2/min
water Fe W10cm
![Page 7: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/7.jpg)
MT Station Examples
Los Alamos (2003): Drift Tubes
Science and Global Security 16 (2008)37–53
INFN : CMS Muon Barrel Chambers
Nucl. Inst. and Meth. A 604 (2009) 738-746.
FIT : Triple GEMs
Nucl. Inst. and Meth. A 652 (2012) 16-20
![Page 8: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/8.jpg)
Requirements of Detectors for MT
• Large Area (~1m2)• High Detction Efficiency (>90%)• High Spatial Resolution (<1mm)
• Cost-effective
![Page 9: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/9.jpg)
RPC
• Resistive Plate Chamber– R. Santonico(in 1980s)
• Large Area• Good Time Solution~1ns
• Acceptable Spatial Resolution– ~1cm
CMS Muon Trigger RPCs by PKU (200
2)
![Page 10: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/10.jpg)
-HV
HV Graphite
Resistive Plate
Working Gas
Resistive Plate
Gruand GraphiteReadout Strips
RPC Brief View
![Page 11: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/11.jpg)
Combination of RPC & Delay-line Readout
90% F134a+9% C4H10+1% SF6
50ml/Min
![Page 12: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/12.jpg)
• Avalenche Signal
General Properties: Signals
• Avalenche +Streamer Signal
![Page 13: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/13.jpg)
General Properties: Detection Efficiency
![Page 14: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/14.jpg)
-HV
![Page 15: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/15.jpg)
Streamer ProfileSigma 7.4±0.2mm
Avalanche ProfileSigma 2.2±0.1mm
Simulation ProfileSigma 2.40mm
![Page 16: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/16.jpg)
Spatial Resolution Measurement
• Residual Method
• ΔX=X2-(X1+X3)/2
![Page 17: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/17.jpg)
Spatial Resolution of Glass RPCs
mmFWHM
mmmm
XXXf
xx
x
xxxx
90.035.2
384.0470.0816.03
2
2
3)2
1()
2
1(
2/)(
223
221
222
2
312
![Page 18: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/18.jpg)
Uniformity
-50mm~-25mm
Res=0.99 mm
-25mm~0mm
Res=0.89 mm
0mm~25mm
Res=0.82 mm
25mm~50mm
Res=0.94 mm
![Page 19: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/19.jpg)
X Y and T readout in ONE RPC
![Page 20: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/20.jpg)
X axis
0.79 mm (FWHM)
for one RPC
Y axis
1.97 mm (FWHM)
for one RPC
Preliminary
Preliminary
![Page 21: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/21.jpg)
MT Station with three 2D-Glass RPCs12+2 channels
1P
2P
RPC 1
RPC 2
RPC 33P
Material
![Page 22: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/22.jpg)
Imaging Result: Empty target
• Empty target
• Mean angle ~15 mrad– Position/Alignment err
or • ~8 mrad
– RPC box, framework• ~10 mrad
Preliminary
![Page 23: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/23.jpg)
Imaging Result: Pb brick 1
• Pb brick 1• 15cm*5.5cm*3.5cm
Preliminary
![Page 24: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/24.jpg)
Imaging Result: Pb brick 2
• Pb brick 2• 24cm*7cm*6cm
Preliminary
![Page 25: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/25.jpg)
Conclusions
• Glass RPCs with LC Delay-line Readout– Simple structrue, stable performance– Efficiency 95~98%– Charge profile measurement
• <1mm(FWHM) in avalenche mode
– Ideal detectors for MT
• MT Station using three 2D-Glass RPCs– Preliminary Test (detection area: 20cm*20cm)– Sensitive to ~cm Pb
![Page 26: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/26.jpg)
MT station with 4 RPCs 3D ImagingComing Soon
![Page 27: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs](https://reader035.fdocuments.us/reader035/viewer/2022062520/56815971550346895dc6b47c/html5/thumbnails/27.jpg)
Thank You!
Email: [email protected] Gmail: [email protected]
Supervisor: Prof. Yanlin YeEmail: [email protected]
Peking University, China