Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at...

9
GATE VALVES

Transcript of Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at...

Page 1: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

GATE VALVE

S

Page 2: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

Structure

A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate to control flow.

Can be controlled by a electric, pneumatic or hydraulic actuator.

Page 3: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

Operating Method

The closure element of a gate valve is a replaceable disk.

To open the valve, the disk is completely removed from the stream and offers virtually no resistance. Therefore, there is little pressure drop across the open gate valve.

A fully closed gate valve provides good sealing due to the 360° disk-to-seal ring contact surface. Proper mating of a disk to the seal ring ensures there is very little or no leakage across the disk when the gate valve is closed.

Page 4: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

Applications

Selection of the right gate valve for applications depends on the many factors that have to be taken into consideration:

The process fluid

Gas

Corrosive or dirty

The operating temperature & pressure

Working environment

Duty and shut off performance

Another factor to be considered for applications is the type of bonnets on the valve which provide leak proof closure.

Screw-in bonnets: this is the simplest, that offers a durable, pressure-tight seal.

Union bonnets: Suitable for applications which require frequent inspection and cleaning. Also provides added strength to the body

Bolted bonnets: Used for larger valves and higher pressure applications.

Page 5: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

Applications Oil or Gas

Process Isolation

Production manifolds surface & subsea

High Integrity Pipeline Protection systems

Pipeline end termination

Emergency shut down

Double block and bleed

Subsea & surface

Severe service

Abrasive flow

High temperatures & Pressures

Corrosive environments

Deep water

Hot tapping

Page 6: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

Advantages

Available in large sizes

Can be used with slurries and viscous liquids

Used as a shut off valve

Easy to maintain and disassemble

Inexpensive

Inherently fire-safe (when used with a metal sheet)

Bidirectional

Page 7: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

Disadvantages Low pressure limitations

Slow open and close time

Erosion of the seat and disk can occur

Poor throttling characteristics

Difficult to repair

Should not be used in sanitary applications

Page 8: Structure A gate valve has a movable "gate" that is raised and lowered by turning a hand wheel at the top to turn a screw which raises or lowers the gate.

Flow Route Often used when a straight-line flow of fluid and minimum restric tion is desired.

The gate faces can form a wedge shape or they can be parallel.

Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose.

Often used in the petroleum industry because of the ability to cut through fluids.

On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percentage of opening. Meaning that flow rate does not change evenly with stem travel.

Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow.

They designed to be fully opened or closed. When fully open, there is no obstruction in the flow path, resulting in very low friction loss. Partially open gates tend to vibrate from the fluid flow.