StoTherm Parapet with Cornice Feature - Sto Corp....StoTherm® ci Parapet with Cornice Feature...

1
StoTherm ® ci Parapet with Cornice Feature Detail No.: 52s.61 Date: November 2015 IMPORTANT: Components not identified as Sto are furnished by other manufacturers and are not necessarily installed by trades who install Sto products. Refer to project specific contract documents. ATTENTION Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional, general contractor or builder. They should be installed in accordance with those specifications and Sto’s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections, for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building components or assemblies, of for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or building may result in serious damage to Sto products, and to the structure of the building or its components. S T O C O R P . D I S C L A I M S A L L W A R R A N T I E S E X P R E S S E D O R I M P L I E D E X C E P T F O R E X P L I C I T L I M I T E D W R I T T E N W A R R A N T I E S I S S U E D T O A N D A C C E P T E D B Y B U I L D I N G O W N E R S I N A C C O R D A N C E W I T H S T O S W A R R A N T Y P R O G R A M S W H I C H A R E S U B J E C T T O C H A N G E F R O M T I M E T O T I M E. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers, please refer to the Sto Corp. website, www.stocorp.com. www.stocorp.com ® N o t e s : 1. Cornice feature limited to 12" (30.5 cm) maximum thickness for noncombustible type construction. Special analysis with regard to fire propagation may enable thicker sections. Thicker sections permitted within practical limits for combustible construction. 2. Cornice feature attached with Sto TurboStick Adhesive; also used as filler and rasped smooth at any gaps between feature band and base layer of insulation board. 3. Cornice feature may also be attached directly to StoGuard where applicable. 4. Supplemental mechanical attachment of feature band maybe necessary in some cases. Verify installation method for adequate attachment before commencing work. - Refer to StoTherm ci System Bulletins and Specifications, Sto Product Bulletins, Tech Hotlines, and Sto Installation and Maintenance Guides for complete information. - Refer to applicable ICC or CCMC Evaluation Reports for building code compliance information. Property of Sto Corp. All Rights Reserved . V i e w o f P r e - W r a p p e d C o r n i c e V i e w o f M e s h O v e r l a p Sto Mesh Embedded in Base Coat Laps Sto Mesh on Cornice 2 1/2 in. (64 mm) min. Sto EPS Insulation Cornice Feature Cornice Feature Pre- Wrapped with Sto Base Coat (with Sto Mesh Embedded) StoGuard ® Transition Membrane Embedded in StoGuard ® Air and Moisture Barrier (or Compatible Roofing Membrane) Wood Construction as Required StoGuard ® Air and Moisture Barrier Sheathing Joint Treatment Extends 2 in. (51 mm) min. at Vertical and Horizontal Surfaces Sto EPS Insulation Board, Back- Wrapped or Pre- Wrapped at Termination Sto Base Coat (with Sto Mesh Embedded) Metal Coping Sto Primer (Optional) Sto Finish Sheathing Backer Rod and Sealant Sto Mesh Light Gauge Steel Stud Framing StoGuard ® Air and Moisture Barrier 1/2 in. (13 mm) min. Gap Between Top Surface of Cornice Feature and Underside of Wood Construction Pre-Wrapped Cornice

Transcript of StoTherm Parapet with Cornice Feature - Sto Corp....StoTherm® ci Parapet with Cornice Feature...

StoTherm® ciParapet with Cornice Feature

Detail No.: 52s.61Date: November 2015

IMPORTANT: Components not identified as Sto are furnished by other manufacturers and are not necessarily installed by trades who install Sto products. Refer to project specific contract documents.

ATTENTION

Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional, general contractor or builder. They should be installed in accordance with those specifications and Sto’s instructions. Sto Corp. disclaims all, and assumes no, liability for on-site inspections, for its products applied improperly, or by unqualified persons or entities, or as part of an improperly designed or constructed building, for the nonperformance of adjacent building components or assemblies, of for other construction activities beyond Sto’s control. Improper use of Sto products or use as part of an improperly designed or constructed larger assembly or building may result in serious damage to Sto products, and to the structure of the building or its components.

STO CORP. DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED EXCEPT FOR EXPLICIT LIMITED WRITTEN WARRANTIES ISSUED TO AND ACCEPTED BY BUILDING OWNERS IN ACCORDANCE WITH STO’S WARRANTY PROGRAMS WHICH ARE SUBJECT TO CHANGE FROM TIME TO TIME. For the fullest, most current information on proper application, clean-up, mixing and other specifications and warranties, cautions and disclaimers, please refer to the Sto Corp. website, www.stocorp.com.

www.stocorp.com

®

Notes:

1. Cornice feature limited to 12" (30.5 cm) maximum thickness for noncombustible type construction. Special analysis with regard to fire propagation may enable thicker sections. Thicker sections permitted within practical limits for combustible construction.

2. Cornice feature attached with Sto TurboStick Adhesive; also used as filler and rasped smooth at any gaps between feature band and base layer of insulation board.

3. Cornice feature may also be attached directly to StoGuard where applicable.

4. Supplemental mechanical attachment of feature band maybe necessary in some cases. Verify installation method for adequate attachment before commencing work.

- Refer to StoTherm ci System Bulletins and Specifications, Sto Product Bulletins, Tech Hotlines, and Sto Installation and Maintenance Guides for complete information.

- Refer to applicable ICC or CCMC Evaluation Reports for building code compliance information.

Property of Sto Corp. All Rights Reserved.

View of Pre-Wrapped CorniceView of Mesh Overlap

Sto Mesh Embedded in Base Coat Laps Sto Mesh on Cornice 2 1/2 in. (64 mm) min.

Sto EPS Insulation Cornice Feature

Cornice Feature Pre-Wrapped with Sto Base Coat (with Sto Mesh Embedded)

StoGuard® Transition Membrane Embedded in StoGuard® Air and Moisture Barrier (or Compatible Roofing Membrane)

Wood Construction as Required StoGuard® Air and Moisture Barrier Sheathing Joint Treatment Extends 2 in. (51 mm) min. at Vertical and Horizontal Surfaces

Sto EPS Insulation Board, Back-Wrapped or Pre-Wrapped at Termination

Sto Base Coat (with Sto Mesh Embedded)

Metal Coping

Sto Primer (Optional)

Sto Finish

Sheathing

Backer Rod and Sealant

Sto Mesh

Light Gauge Steel Stud Framing

StoGuard® Air and Moisture Barrier

1/2 in. (13 mm) min. Gap Between Top Surface of Cornice Feature and Underside of Wood ConstructionPre-Wrapped

Cornice