Step 2: Click on the stream which you wish to size the pipe. Select Sizing from the menu, then select Pipes
![Page 3: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/3.jpg)
Step 3: Click on Select streams from flowsheet.
![Page 4: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/4.jpg)
Step 4: Click on Typical sizing for single phase. Then enter the Pipe Schedule. Schedule 40 is used for pipes less than 150 psig.
![Page 5: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/5.jpg)
Step 5: Note the Nominal Dia. If it is in feet, you can change the units to inches under the Engineering Units menu
![Page 6: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/6.jpg)
Step 6: Select the stream, then click on Sizing, then Control Valve
![Page 7: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/7.jpg)
Step 7: Enter the downstream pressure. Assume that it will be 10 psi less than the stream pressure
![Page 8: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/8.jpg)
Note the Capacity Coefficient, Cv
![Page 9: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/9.jpg)
Insert a control valve in the stream, then enter the Valve flow coefficient (Cv), select Fix valve position, adjust flow rate in the Operating mode, and then enter 50 for the Valve position %. Enter the downstream pressure even if it is not known.
![Page 10: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/10.jpg)
Run the program. You can change the valve position to give the desired flow rate.
![Page 11: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/11.jpg)
Insert a node before and after the control valve
![Page 12: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/12.jpg)
![Page 13: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/13.jpg)
For the upstream node, set the Mode to Fixed Pressure, and enter the pressure at the node. Select Free inlet stream for the inlet and Flow set by UnitOp for the outlet
![Page 14: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/14.jpg)
Enter the outlet pressure for the outlet node, and Flow set by UnitOP for the inlet and Free Outlet stream for the outlet.
![Page 15: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/15.jpg)
Open up the control valve menu and delete the Downstream pressure. Then enter the node number for the Destination ID and Node Pressure for the variable
![Page 16: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/16.jpg)
Insert a Pipe Simulator and another node.
![Page 17: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/17.jpg)
Click on the pipe, and enter the Method, the Sizing option, the Pipe diameter, Pipe Schedule, Pipe Length, and Pipe Material
![Page 18: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/18.jpg)
Reset the Node settings for the node before the pipe.
![Page 19: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/19.jpg)
For the last node, use the following parameters:
![Page 20: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/20.jpg)
Insert a PID Controller at the outlet of the last node
![Page 21: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/21.jpg)
Activate the controller, enter the desired set point, the sensor min and max, the proportional band, the control valve ID number, select Reverse for the controller action, and select what is to be measured. Make sure the Engineering Units are set for the units that you desire for the set point.
![Page 22: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/22.jpg)
Open up the control valve dialog box and enter the Controller ID
![Page 23: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/23.jpg)
Click on the Run menu and select Convergence.
![Page 24: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/24.jpg)
Select Dynamics under the Steady State/Dynamics menu
![Page 25: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/25.jpg)
Select Dynamics under the Run menu.
![Page 26: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/26.jpg)
Click on Set run time.
![Page 27: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/27.jpg)
Enter the Run Time and Step size in the Step 1 menue
![Page 28: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/28.jpg)
Click on Record Streams and enter the streams which you wish to plot
![Page 29: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/29.jpg)
Select the frequency you wish to plot and then click on Plot Stream Properties
![Page 30: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/30.jpg)
Check the properties you wish to plot. After clicking OK, click on Run from Initial State
![Page 31: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/31.jpg)
![Page 32: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/32.jpg)
Continue to decrease the Proportional Band until your plot looks similar to the above
![Page 33: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/33.jpg)
Start off with a large Integral time for the PID controller and decrease it until a stable value is obtained as quickly as possible.
![Page 34: Step 1: Set the desired flow rate for each pipe](https://reader035.fdocuments.us/reader035/viewer/2022062314/568134cf550346895d9bf59c/html5/thumbnails/34.jpg)
Assignment: Set up a piping network that can deliver 20 gpm of water at 75 F to each of three floors of a building. One floor is at a 50 ft elevation, the second is at 30 ft, and the third is at 15 ft. Water is available at 60 psia. The outlet pressure at each floor will be at 14.7 psia. Size the piping and control valves under steady state conditions without using the nodes. Once the pipes and valves are sized, begin to optimize the PID tuning one valve at a time. If you try to do it all at once, you will be guaranteed to have problems.