Steel City - Kirby Risk Corporation · PDF file · 2010-08-07Steel City Octagon...

3
Steel City Octagon Boxes 54151-!^& 3 /4 54151-V-'^ "V" bracket recessed %" 4" Octagon Boxes Knockouts Cat. No. Clamps Ears Brkts. Ea. Side Ea. End Ea. End Bottom Std. Conduit Conduit Cable Conduit Ctn. VA" deep—with conduit KOs—15.8 cubic inch capacity 54151-!^ 541 51-% 54151- 1 /4& 3 /4 541 51 -V- 1 ^ 541 51 -L-'/ 54151-J-!4 V L With Bar Hanger 1—V 1—%" 1—# 1—// 1— W 1—<A" 1—# 1—V 1—r 1— %" 1—# 1—14" 5—%" 3— /?" 2— 3 /v 3— J*" 2—W 5— /2 1 ' 5—%" 4—W 50 50 50 25 25 25 50 Ib. max loading for fixtures. 54151 -J-l* Mounted on 6010-P bar adjustable 1ffA" to WA". Offset for V", */," or 7 A" plaster. Maximum horizontal positioning. %" fixture stud. 54151 -L-!4 "L" bracket flush mounted 54151-N 54151-ML "L" bracket flush mounted 54151-NE Adjustable ears recessed %" 54151-NV "V" bracket recessed %" 4" Octagon Boxes—Continued Cat. No. Bar Hanger Number Bar Lgth. (in.) Offset For Stud Std. Ctn. VA" deep—with nonmetallic sheathed cable clamps—15.8 cubic inch capacity 54151-N C-5 54151-NE C-5 54151-NL C-5 54151-NV C-5 L V 1— W 1— V-" 1— W ^ff 1—#' 1— W 1—!*' -\—W so: 50 50 50 VA" deep—for nonmetallic sheathed cable—15.8 cubic inch capacity 54151-NF 54151-NO 54151-NG 54151-NP 6010-DW 6010-ADW 6011-DW 6011-ADW 10^-18 1 / 14/2-26^ 10^-18^ 14/2-26/2 Fastener Fastener 25 25 25 25 VA" deep—for armored cable/metal clad—15.8 cubic inch capacity 54151-AF 6010-DW 10I4-18 1 / Drywall %" 25 54151-N octagon box mounted on adjustable bar hanger. 50 Ib. load max rating 54151-A octagon box mounted on adjustable bar hanger 50 Ib. load max rating ThomasiBetts D15

Transcript of Steel City - Kirby Risk Corporation · PDF file · 2010-08-07Steel City Octagon...

Page 1: Steel City - Kirby Risk Corporation · PDF file · 2010-08-07Steel City Octagon Boxes 54151-!^&3/4 54151-V-'^ "V" bracket ... — — With Bar Hanger 1 ... Bar Hanger Number Bar Lgth.

Steel CityOctagon Boxes

54151-!^&3/4 54151-V-'^"V" bracketrecessed %"

4" Octagon BoxesKnockouts

Cat.No. Clamps Ears Brkts.

Ea. Side Ea. End Ea. End Bottom Std.Conduit Conduit Cable Conduit Ctn.

VA" deep—with conduit KOs—15.8 cubic inch capacity54151-!̂541 51-%

54151-1/4&3/4

541 51 -V-1^541 51 -L-'/54151-J-!4

— — —— — —

— — —

— — V— — L— — With Bar

Hanger

1— V1—%"

1— #

1— //1— W1—<A"

1— # —1— V —

1— r —

1— %" —1— # —1—14" —

5—%"3— /?"2— 3/v3— J*"2—W5— /21'5—%"4—W

5050

50

252525

50 Ib. max loading for fixtures.

54151 -J-l*Mounted on 6010-P bar adjustable 1ffA" toWA". Offset for V", */," or 7A" plaster. Maximumhorizontal positioning. %" fixture stud.

54151 -L-!4"L" bracket flush

mounted

54151-N

54151-ML"L" bracket flush

mounted

54151-NEAdjustable ears

recessed %"

54151-NV"V" bracketrecessed %"

4" Octagon Boxes—Continued

Cat.No.

BarHangerNumber

BarLgth.(in.)

OffsetFor Stud

Std.Ctn.

VA" deep—with nonmetallic sheathed cable clamps—15.8 cubic inch capacity54151-N C-554151-NE C-554151-NL C-554151-NV C-5

LV

1— W1— V-"1— W^ff

1—#'1— W1—!*'-\—W

so:505050

VA" deep—for nonmetallic sheathed cable—15.8 cubic inch capacity54151-NF54151-NO54151-NG54151-NP

6010-DW6010-ADW6011-DW6011-ADW

10^-181/14/2-26^10^-18^14/2-26/2

FastenerFastener

25252525

VA" deep—for armored cable/metal clad—15.8 cubic inch capacity54151-AF 6010-DW 10I4-181/ Drywall %" 25

54151-N octagon box mounted onadjustable bar hanger.50 Ib. load max rating

54151-A octagon box mounted onadjustable bar hanger

50 Ib. load max rating

ThomasiBettsD15

Page 2: Steel City - Kirby Risk Corporation · PDF file · 2010-08-07Steel City Octagon Boxes 54151-!^&3/4 54151-V-'^ "V" bracket ... — — With Bar Hanger 1 ... Bar Hanger Number Bar Lgth.

Steel CitySwitch Boxes

Table 370-16(b). Volume Required per Conductor

Size ofConductor

Free SpaceWithin Box

For EachConductor

No. 18...No. 16...No. 14...,No. 12...No. 10...No. 8.....No. 6.....

1.501.752.002.252.503.005.00

cu. in.cu. in.cu. in.cu. in.cu. in.cu. in.cu. in.

Reprinted with permission from National Fire Protection Association 70-1987. NationalElectrical Code, Copyright© 1986, National Fire Protection Association, Quincy, MA 02269.This reprinted material is not the complete and official position of the NFPA on the referencedsubject which is represented only by the standard in its entirety.NEC" is a registered trademark of the National Fire Protection Association, Inc., Quincy, MA02269.Underwriters Laboratories inc. File Number: £2969 (U.L 514A)Canadian Standards Association File Number: LR 12798Federal Manufacture Number: 78229Products Designed To Meet Federal Specification Number: W-J-800Verification of file numbers and compliance with federal specifications for individual itemsavailable upon request.Box and Cover Material and Plating Specification; .062" minimum thickness, Hot Rolled, Pregalvanized steel, minimum spangle.ASTM G-90-U, AISI C-1008Bracket Material: All brackets except MS style; 16 gauge (.060") Hot Rolled, Pre galvanizedSteel AISI C-1008, G-90-U. MS Style bracket; 20 gauge (. 036") Cold Rolled Spring Steel AISIC-1055, Heat Treated to R. 35 Zinc Plated .0005 thick.Patent Number 5,031,789 - Standoff for Outlet Boxes - SS-1 Patent Number 5,004,199 - MetalStud Bracket - Type MS - Eccentric Knockouts - Type Eko

Metallic Boxes—Fire Resistance Rating________Wall PenetrationsListed single and double gang metallic outlet and switch boxes and octagonceiling boxes with metallic or nonmetallic cover plates may be used in bearing andnonbearing wood stud and steel stud walls with ratings not exceeding 2 hr. Thesewalls shall have gypsum wallboard facings similar to those shown in Design Nos.U301, U411, and U425. 4 in. square boxes may be used in 2 hr. fire rated ceilings.

The surface area of individual metallic outlet or switch boxes shall not exceed 16 sq. in. Theaggregate surface area of the boxes shall not exceed 100 sq. inches . Boxes located onopposite sides of walls or partitions shall be separated by a horizontal distance of 24 in.The metallic outlet or switch boxes shall be securely fastened to the studs and the opening inthe wallboard facing shall be cut so that the clearance between the box and the wallboarddoes not exceed 'A in.

ThomasiBettsD4

Page 3: Steel City - Kirby Risk Corporation · PDF file · 2010-08-07Steel City Octagon Boxes 54151-!^&3/4 54151-V-'^ "V" bracket ... — — With Bar Hanger 1 ... Bar Hanger Number Bar Lgth.

Steel CitySwitch Boxes

w

wESS^m

Guide to Steel City Brackets and ClampsBrackets

"S" or "B" TypeMounts to face of stud. Used onswitch, handy or square boxes.2" long -2H" wide

"T' TypePositions handy box against thelace and side of stud. 5!^" long •'A" wide

SV" TypeMounts box to side of stud withpositioning spikes. TWIong-1" wide -'A"offset

"CV" Type (Outlet Boxes)Mounts to flat side of metal studsor wood studs. 7W long -1" wide -W off set

"DV" TypeMounts box offset from stud TA".6^1" long • T'wide - W offset

Clamps

f~^~<\ /"~~N-Vl__<

C-1

"MS" Type (For Metal Studs)Mounts to any depth of metal stud,open or closed side. Patentedbracket. 2!flong - 7%" wide -%" offset

"L" TypeUsed to toe mount octagon boxes.?A" long - W wide - W offset

"V" TypeMounts to flat side of stud.T/T long -1" wide • W offset

For armored cable

C-8 C-10(Loom only)

For nonmetallic sheathed cable andnonmetallic tubing (loom)

UNDERWRITERS LABORATORIESINC. and CANADIAN STANDARDSASSOCIATION file numbers forindividual items available uponrequest. "Products listed in thiscatalog are subject to alteration ordiscontinuation without prior notice."

C-5 C-3

Listing Information for Armored Cable Clamp—Type C-3Armored Cable (BX) - SteelArmored Cable (BX) - AluminumMC Interlocked (MCI) - SteelMC Interlocked (MCI) - AluminumMC Corrugated (MCC) - AluminumFlex Metal Conduit - SteelFlex Metal Conduit - AluminumC-3 Clamp Acceptable for Grounding

Sizes 14-2 through 10-3Sizes 14-2 through 10-3.449 - .570 diameter.476 - .606 diameter.375 - .515 diameter3A" trade size3A° trade size

ThomasiBettsD6