PDA (high strain) and STN (statnamic), both method are the ...
Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN...
-
Upload
phungtuong -
Category
Documents
-
view
219 -
download
2
Transcript of Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN...
![Page 1: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/1.jpg)
www.fugro.com www.fugro.frDate
Statnamic Pile Load Testing
Flip Hoefsloot, Fugro The NetherlandsJanuary 2010
![Page 2: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/2.jpg)
www.fugro.com www.fugro.frDate
Contents Menu
Load Testing Methods
Description Statnamic
Video of TestApplication
Interpretation
GuidelinesConclusion
![Page 3: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/3.jpg)
www.fugro.com www.fugro.frDate
Load Testing Methods
STATIC
100 %
Load
Displacement
DYNAMIC
1-2 %
STATNAMIC
5-10%
High pressure gas
High pressure gas
Strain
Acceleration
Load
Displacement
![Page 4: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/4.jpg)
www.fugro.com www.fugro.frDate
Description Stanamic
1 2
3 4
A = Pile B = Load cellC = Cylinder D = Piston with chamberE = PlatformF = SilencerG = Reaction massH = Gravel ContainerI = GravelJ = LaserK = Laser beamL = Laser sensor
![Page 5: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/5.jpg)
www.fugro.com www.fugro.frDate
Fugro Profound
Knowledge and experienceStatnamic(Peter Middendorp)
ClientsWord wide
Description Stanamic
![Page 6: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/6.jpg)
www.fugro.com www.fugro.frDate
Hydraulic Catching Mechanism
Containers filled with local material (gravel or equivalent)
4 test a day
Simple inspection ignition system
Transport on one trailer
Description Stanamic
![Page 7: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/7.jpg)
www.fugro.com www.fugro.frDate
Equipment:
80 tons reaction mass
7 trailers for transport2 to 3 days a test
one cycle of testing
Description Stanamic
![Page 8: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/8.jpg)
www.fugro.com www.fugro.frDate
Video of Test
![Page 9: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/9.jpg)
www.fugro.com www.fugro.frDate
Application, Static Load Test
Advantages:
•Static behaviour
•Separation of:
•End Bearing
•Shaft Friction
Disadvantages:
•Cost
•Selection of Test Piles
![Page 10: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/10.jpg)
www.fugro.com www.fugro.frDate
Application, Dynamic Load Test
Advantages:
•Low Cost
•Test on all Piles
Disadvantages:
•Dynamic Pile-Soil behaviour
•High stresses in Pile
•Requires advanced analyzingTechniques
•Applicable only for Steel PipePiles
![Page 11: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/11.jpg)
www.fugro.com www.fugro.frDate
Application, Statnamic Load Test
Advantages: Relatively low Cost
Free selection of test Piles
Disadvantages: Difficult to determine Bearing Capacity
Difficult to distinguish between End Bearing and Shaft Friction
Application: Re-use of existing Piles
Load-Settlement behaviour
Condition: Tf Duration of rapid loadL pile lengthcp stress wave velocity test pile
1000/
10 ≤≤p
f
cL
T
![Page 12: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/12.jpg)
www.fugro.com www.fugro.frDate
Interpretation
Fstn = statnamic force, measuredFst = static resistanceu = displacement, measuredv = du/dta = d2u/dt2
m = pile massC = damping coefficient
)()()()( tvCtamtFtF ststn ⋅+⋅+=
M
Fstn
u F stn
k C
m
![Page 13: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/13.jpg)
www.fugro.com www.fugro.frDate
Interpretation
Load Cell
Laser Sensor
Accelerometer
0
5
10
15
200 50 100 150 200 250 300
Time [ms]Lo
ad [M
N]
0
10
20
30
40
50
60
0 50 100 150 200 250 300
Time [ms]
Dis
plac
emen
t [m
m]
![Page 14: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/14.jpg)
www.fugro.com www.fugro.frDate
Interpretation
Estimated damping parameter C (hyperbolic curve)
0
10
20
30
40
50
60
0 5 10 15 20
Load [MN]D
ispl
acem
ent [
mm
] .
Fstn(t)
Fstatic(t)
UP
)()()()( tvCtamtFtF stnst ⋅−⋅−=
![Page 15: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/15.jpg)
www.fugro.com www.fugro.frDate
Interpretation
Simplified input ofdynamics boundary conditions withMicrosoft notepad
Dynamic Analysis, PLAXIS
![Page 16: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/16.jpg)
www.fugro.com www.fugro.frDate
Interpretation
Dynamic Analysis, PLAXIS
Calibration model with static behaviourAverage damping parameter selected based on hyperbolic curve
Statnamic Test Numerical Simulation PLAXIS
![Page 17: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/17.jpg)
www.fugro.com www.fugro.frDate
Interpretation
Extrapolation according toMiddendorp and Bakker
Correction for “rate effects”:
Undrained behaviour
0
20
40
60
80
100
120
140
160
180
200
0 5 10 15 20 25
Load [MN]
Dis
plac
emen
t [m
m]
.
Fstn(t)
Fu(t)
Hyperbolic F=u/(p+q.u)
Hyperbolic F=Fref(u/uref)^0.5 0 0,05 0,10 0,15 0,20
-5000
-4000
-3000
-2000
-1000
0
|U| [m]
Fy [kN/rad]
Drained analysis
Undrained analysis
“Rate effect”
![Page 18: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/18.jpg)
www.fugro.com www.fugro.frDate
30
25
20
15
10
5
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Bochum, Pfahl 57STN Cyclic Load Displacement Diagram
Dis
plac
emen
t [m
m]
Load [MN]
Cycle 1 Cycle 2 Cycle 3
30
25
20
15
10
5
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Bochum, Pfahl 57STN Static Cyclic Load Displacement Diagram
Dis
plac
emen
t [m
m]
Load [MN]
Cycle 1 Cycle 2 Cycle 3 Hyp. Appr. Static QuickHyp. Appr. Static Long Term
Interpretation
![Page 19: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/19.jpg)
www.fugro.com www.fugro.frDate
Guidelines
The Netherlands
� CUR-comittee H410 “Rapid load tests”� goal: preparation European Codes� Fugro is member (Maarten Profittlich)
European Codes
� Draft standard Rapid Load Testing procedure� Working group 4 of TC 341� (Testing of geotechnical structures; Testing of piles: rapid load testing (reference
EN-ISO 22477-# version: 3.3, 23 April 2008)
� Guideline on the interpretation of Rapid Load test on piles� 7 November 2008
![Page 20: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/20.jpg)
www.fugro.com www.fugro.frDate
Conclusion
Statnamic provides alternative in case
� Static load tests are not feasible
� Re-use of existing Piles
� Determine Load-Settlement behaviour
![Page 21: Statnamic Pile Load Testing - Accueil | CFMS · · 2012-01-19Disadvantages: Difficult to ... STN Cyclic Load Displacement Diagram Displacement [mm] Load ... preparation European](https://reader031.fdocuments.us/reader031/viewer/2022022507/5ac3e0eb7f8b9a333d8cae17/html5/thumbnails/21.jpg)
www.fugro.com www.fugro.frDate
Thank You