Our stationary fixed network system Z.RTU consists of a data logger (RTU1) with an embedded web-server for the collection resp. recording of the con-sumption data compatible with most popular water-, heating and cooling-meters and heat cost alloca-tors equipped with meters that communicate using the M-Bus and wireless M-Bus (868 MHz protocol, C1,T1, T2 or S1 mode).
In addition to the data logger, up to 23 mains-pow-ered, multihop capable wireless M-Bus repeaters are used in order to increase the radio range inside the building using a Mesh network and to ensure that all meters are accessible.
With this system, the data of up to 500 meters (shared between wired and wireless M-Bus devices)
can be collected and recorded for 10 years for each daily reading. The RTU can handle directly up to 20 wired M-Bus slaves but by using an additional level converter the number of wired M-Bus devices can be increased to 250 slaves.
The embedded webserver allows accessing data, re-ports generating, the setup of the M-Bus networks and the management of local inputs and outputs (I/O). The system configuration, accessing data and the overview via I/O status can be managed via a graphical display without the need of a PC.Automated email-sending of consumption data is possible. The transfer intervals can be selected from predefined cycles.
Data transfer to an FTP server is also possible.
M-Bus / wM-Bus-Datalogger with integrated
Webserver
for submetering applications,
Readout system for energy meters with M-Bus /
wM-Bus protocol
Stationary read-out-system Z.RTU
Data-management
Gateway RTUEthernet Interface, integrated webserver
wM-Bus repeater
wM-Bus converter (PDC)
meters with pulse output
wM-Bus meters
Customer ownedBilling- orMonitoring Portal
w M-Bus
ftp://
E-Mail-Ex-port
ftp- Export
ZENNER wireless M-BUS Fixed Network System
Data export
Smart Metering Functions: ■ Webserver-based data logger ■ Manages up to 500 devices (wireless and wired together), 20 wired M-Bus meters directly (up to 250 wired by using an additional level converter) ■ Data log file of daily synthetic data for up to 10 years ■ Data logging interval between 15 minutes and 1 month ■ Remote system management, meters reading, report sending, alarm management, event manage-ment, 3 digital inputs for logic control and remote control ■ 2 relay outputs for logic control and remote control ■ Graphic, bright, 16 grayscale, multilingual display for local consultation and configuration
Performance characteristics: ■ Operating temperature range: [-10 / +55 °C] ■ Storage temperature range: [-25 / +65 °C] ■ Protection Rating: IP20 (EN60529) ■ Fastening: 35mm DIN bar (EN60715) ■ Dimensions: 4 DIN modules (90x72x64.5) ■ Power Supply: 24Vdc +/- 10%, 24Vac (min 20Vac, max. 40Vac) ■ Power consumption: Max. 7,5W
wM-Bus-Repeater
Performance characteristics: ■ Easy to use - The user-friendly and intuitive entry forms allow an easy commissioning of the system. ■ Always updated –Through the Internet the data logger RTU1 will check for updates and notify the user who can decide to install them with a simple click in the web interface. ■ Smart - The user can start scanning the M-Bus network to allow the acquisition of devices connected via cable or via radio through a single button.
Sub
ject
to m
odifi
catio
ns a
nd e
rror
s ex
cept
ed. A
ny li
abili
ty fo
r mis
prin
ts e
xclu
ded.
SA
P15
3785
_160
309_
EN
ZENNER International GmbH & Co. KGRömerstadt 6 D-66121 Saarbrücken
Telephone +49 681 99 676-30Telefax +49 681 99 676-3100E-Mail [email protected] www.zenner.com