Static Stray DC Current Interference Testing Intermediate Corrosion Course 2017 February 21-23, 2017 Mike Placzek – ARK Engineering 1 Period 6

Transcript of Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... ·...

Page 1: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Static Stray DC Current Interference Testing

Intermediate Corrosion Course 2017

February 21-23, 2017 Mike Placzek – ARK Engineering 1

Period 6

Page 2: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 2

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 3: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Agenda

• What is Stray current? • How do,

– we recognize stray current? – we test for stray current? – we remediate stray current?

February 21-23, 2017 Mike Placzek – ARK Engineering 3

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 4: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Definition of Stray Current

Stray current is defined as “current through paths other than the intended

circuit”.

February 21-23, 2017 Mike Placzek – ARK Engineering 4

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 5: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Types of Interference There are two types of stray current interference

• Static • Static interference is a steady, continuous stray current source: such

as an impressed cathodic protection rectifier • Normally can be found with a typical data logging method

• Dynamic

• Dynamic interference fluctuates in magnitude and direction, from sources such as, mines, subways, and light rail cars

• Normally requires recording charts to catch the stray current data due to the fluctuations

This class deals with static current. The following class will cover dynamic current

February 21-23, 2017 Mike Placzek – ARK Engineering 5

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 6: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

When Stray Current is Identified

• Time is of the essence

• Leakage can occur with in days or weeks

• This is because stray current can be large – many amps

February 21-23, 2017 Mike Placzek – ARK Engineering 6

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 7: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Rates of Metal Loss Fe (Iron) / STEEL 20Lbs /Amp/ Year

Al (Aluminum) 6.5 Lbs Cu (Copper) 45.7 Lbs Pb (Lead) 74.5 Lbs Mg (Magnesium) 8.8 Lbs Zn (Zinc) 23.6 Lbs

Basic Faradays’ Law

February 21-23, 2017 Mike Placzek – ARK Engineering 7

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 8: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Given: 1 amp of current discharging from a

pipeline for 1 year. Metal loss: Approximately 20 lbs.

EQUIVALENT METAL LOSS

Equivalent Length

Pipe Diameter/W.T. Pipe Weight/Foot of Pipe Loss

4” = 4.500” O.D. x 0.188 W.T 8.66 lbs/ft. 2.31 ft.

6” = 6.625” O.D. x 0.280 W.T. 18.97 lbs/ft. 1.05 ft.

10” = 10.750” O.D. x 0.188 W.T. 21.21 lbs/ft. 0.94ft.

16” = 16.000” O.D. x 0.250 W.T. 42.05 lbs/ft. 5.70 in.

20” = 20.000” O.D. x 0.250 W.T. 52.73 lbs/ft. 4.55 in.

February 21-23, 2017 Mike Placzek – ARK Engineering 8

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 9: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Identifying • Pipe to soil potentials indication of possible

interference situation • Structural effect of stray current pickup and

discharge • Foreign lines or other structures with CP being

applied nearby

February 21-23, 2017 Mike Placzek – ARK Engineering 9

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 10: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Identifying • Pipe to soil potentials indication of possible

interference situation – Area of monitoring or surveying, Pipe to soil

readings of high negative potentials and some with more positive potentials, may indicate pick up and discharge areas of stray current

February 21-23, 2017 Mike Placzek – ARK Engineering 10

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 11: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Identifying • Structural effect of stray current pickup and

discharge – Corrosion takes place very rapidly – Leakage occurs despite CP system – Coating disbondment – At pipeline crossings, signs of corrosion or pitting

(metal loss)

February 21-23, 2017 Mike Placzek – ARK Engineering 11

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 12: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Identifying • Foreign lines or other structures with CP

being applied nearby – Such as -

• other pipelines • buried tanks or petroleum facilities • New constructions • New rectified installation

– Local corrosion committees

February 21-23, 2017 Mike Placzek – ARK Engineering 12

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 13: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Conventional Current Flow

• Conventional current will flow - from positive to negative, – From the foreign ground bed system to the

company pipeline pickup area – Through the pipeline to the discharge area – From the discharge area (company pipe surface)

to the foreign structure through the electrolyte

February 21-23, 2017 Mike Placzek – ARK Engineering 13

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 14: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Conventional Current Flow – Rectified System

Positive (+)

Negative (-)

Current Flow

Current Flow

Anode bed

Structure - Pipeline

Rectifier Unit

(+)

February 21-23, 2017 Mike Placzek – ARK Engineering 14

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 15: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Conventional Current Flow – Rectified System

Positive (+)

Negative (-)

Current Flow

Current Flow

Anode bed

Structure - Pipeline

Rectifier Unit

(+)

Discharge

Pick Up

February 21-23, 2017 Mike Placzek – ARK Engineering 15

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 16: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Ion Flow

• If adequate polarization exists, the current discharge will lead to an Ionic exchange and no metal loss

• No corrosion occurs • Reduces the level of cathodic polarization • So long as potential of interfered line remains

at or above the criterion, no corrosion will occur

February 21-23, 2017 Mike Placzek – ARK Engineering 16

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 17: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Ion Flow

• If inadequate polarization exists, the discharge of current will cause metal loss

February 21-23, 2017 Mike Placzek – ARK Engineering 17

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 18: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 18

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

-

+

e- e- e- e- e- e- e- e-

H2O

H2O

H2O

H2O

Area approaches positive state – considered discharge area

Area approaches negative state – considered pick up area

- Rectifier

Company

Pipeline e- e- e- e- e- e- e-

H++ H++ H++ H++

H++

Fe+

Fe+

Fe+ Fe+ HO-

HO-

HO-

+

Fe+

Fe+

Fe+

HO-

HO-

HO-

H++ H++

H++ H++

H++ H++

H++ H++

Page 19: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Foreign Stray Current Affect on Polarization

• Stray current pickup increases polarization, this is represented by the higher,more negative, pipe-to-soil readings

• Stray current discharge decreases polarization, this is represented by a more positive or less negative pipe-to-soil readings

February 21-23, 2017 Mike Placzek – ARK Engineering 19

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 20: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Pick Up and Discharge Areas

• Need to identify areas of Pick up and Discharge – Pick up area,

• More negative

– Discharge area, • More Positive

• Determine locations by CIS or other pipe to soil potential survey – Interrupting foreign structure – Data logger is the best tool to use

February 21-23, 2017 Mike Placzek – ARK Engineering 20

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 21: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Interference Consideration

• Separation and routing of facilities

• The location of the interfering current source

• Magnitude of the current

• No external coating on the structures involved

• Presence and location of mechanical joints of high electrical resistance and/or isolators

February 21-23, 2017 Mike Placzek – ARK Engineering 21

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 22: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Static interference caused by a cathodic protection system

Conventional Current Flow

+

-

Current returns through the soil

Current Discharge –

Corrosion

Current Discharge –

Corrosion February 21-23, 2017 Mike Placzek – ARK Engineering 22

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 23: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Foreign Line Crossing and Stray Current Pickup and Discharge

Conventional Current Flow

Current Discharge –

Corrosion

February 21-23, 2017 Mike Placzek – ARK Engineering 23

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 24: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Discharge Area

• Indicated in CIS as the most positive potential reading

• The area considered anodic • The area that will corrode

– Faraday's law = 1amp = 20lbs per yr

• Most likely found at the point of crossing or the maximum exposure to the foreign line

• The location for the bond to be established

February 21-23, 2017 Mike Placzek – ARK Engineering 24

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 25: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 25

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Connect Interrupter in series with the structure or ground cable. In this case, we used the structure cable.

Page 26: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 26

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Interrupter MCM used to find peak and valleys of reads.

Page 27: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Graph of Stray Current Pickup and Discharge on Bare Pipeline

February 21-23, 2017 Mike Placzek – ARK Engineering 27

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 28: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Graph of Stray Current Pickup and Discharge on Coated Pipeline

February 21-23, 2017 Mike Placzek – ARK Engineering 28

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 29: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Pipe-to-Soil Readings Through Foreign Influence and Resultant Depression in Potentials

February 21-23, 2017 Mike Placzek – ARK Engineering 29

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 30: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Rules of Thumb - Interference Testing

1. Current must always return to its source.

2. Get the “big picture” of all metallic structures and possible stray current sources

February 21-23, 2017 Mike Placzek – ARK Engineering 30

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 31: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Interference Testing Rules of Thumb

4. Follow the data if practical by finding the corresponding stray current discharge point when a stray current pickup is found.

5. Simplest test is to measure the metallic voltage shifts.

February 21-23, 2017 Mike Placzek – ARK Engineering 31

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 32: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

The greatest voltage shift

February 21-23, 2017 Mike Placzek – ARK Engineering 32

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 33: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Beware of Interference Testing Difficulties

• Limited access to the pipelines due to blacktop or concrete requires drilling to obtain measurements

• Testing is complex and time consuming

• Testing may require substantial number of

current interrupters that are synchronizable

February 21-23, 2017 Mike Placzek – ARK Engineering 33

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 34: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Beware of Interference Testing Difficulties

If you have more then one rectifier, you need to have synchronizable current interrupters.

Time programmable Master – Slave GPS

February 21-23, 2017 Mike Placzek – ARK Engineering 34

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 35: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Testing Criterion

• It is necessary prior to conducting any field-testing to gain agreement on what criterion will be utilized to test, evaluate, interpret, and mitigate any stray current problems that may be identified.

• Prior to conducting field tests all parties should agree to the standard remediation requirements.

February 21-23, 2017 Mike Placzek – ARK Engineering 35

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 36: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Interference Testing Outline Summary

Why an ON/OFF Survey? • An ON survey alone does not give insight into the actual

condition of pipe regarding its actual cathodic protection

• “ON” potentials have included in the measurement – IR through the soil – IR in the pipe – Chemical activity representing polarization – Native potential of the steel

February 21-23, 2017 Mike Placzek – ARK Engineering 36

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 37: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Interference Testing Outline Summary

Why an ON/OFF Survey? Continued

• Instant “OFF” potentials include only the static potential of the steel and the chemical polarization. By simultaneously shutting off the current, the IR through the soil and steel of the pipe is eliminated

• The actual (chemical) polarization of the pipeline is determined after static potentials are obtained

Instant OFF – Static = chemical Polarization

February 21-23, 2017 Mike Placzek – ARK Engineering 37

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 38: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Interference Testing Outline Summary

Determine the Acceptable Amount of Interference:

• If the potentials of the pipeline is above the .850- V CSE criteria with the foreign line CP operating, this indicates adequate polarization on the Company’s pipeline to prevent corrosion

• However, you must consider the IR drops

February 21-23, 2017 Mike Placzek – ARK Engineering 38

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 39: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

• Interrupt the foreign structure • Perform CIS over the Company’s structure • Set interrupter • Log survey on data logger • Identify Low points & High points on the “ON” cycle • Identify & measure Voltage shift to the most positive

direction (maximum exposure area) • Mark locations

Interference Testing Outline Best Practice

February 21-23, 2017 Mike Placzek – ARK Engineering 39

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 40: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Mitigation

February 21-23, 2017 Mike Placzek – ARK Engineering 40

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 41: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Mitigation of Stray Current 1. Design and install electrical bonds of proper

resistance between the affected structures. 2. Cathodic protection current can be applied to the

affected structure at those locations where the interfering current is being discharged. The source of cathodic protection may be galvanic or impressed current anodes.

3. Adjustment of the current output from the interfering cathodic protection rectifiers may resolve interference problems.

February 21-23, 2017 Mike Placzek – ARK Engineering 41

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 42: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Mitigation of Stray Current 4. Relocation of the groundbeds of cathodic

protection rectifiers can reduce or eliminate the pickup of interference currents on nearby structures.

5. Rerouting of proposed pipelines may avoid sources of interference current.

6. Properly located isolating fittings in the affected structures may reduce interference problems.

7. Application of external coating to current pickup area(s) may reduce or resolve interference problems.

February 21-23, 2017 Mike Placzek – ARK Engineering 42

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 43: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Resolution of Interference Problems

Indications that interference or stray current problems have been resolved:

• Interrupt system (Foreign structure) • Perform CIS with data logger • Indication that “interferred line is returned to its

“natural potential” • Indication of no voltage shift or very little (“no

swing” method. Requires more drain current than “natural potential)

February 21-23, 2017 Mike Placzek – ARK Engineering 43

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 44: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Bond at foreign pipeline crossing February 21-23, 2017 Mike Placzek – ARK Engineering 44

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 45: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Reverse Switch or Diodes Used

• Diodes are used to prevent back flow of

current through the bond – from protected line to the interferred line

February 21-23, 2017 Mike Placzek – ARK Engineering 45

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 46: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Setting a Resistant Bond – Best Practice

• Attach two no. 8 and no. 12 wires onto both structures (Company and foreign structure)

• Wire sizes may change due to design of higher expected ampere output greater than 60 amps of current

• Mark the foreign structure wires for easy identification (normally with white or red tape)

• Connect an high impedance volt meter to the company no. 12 wire and place the CSE over the maximum exposure area

• Document wire configuration

February 21-23, 2017 Mike Placzek – ARK Engineering 46

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 47: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Setting a Resistant Bond – Best Practice

• Connect an amp meter in series with the Company and the foreign structure to achieve the maximum current drain reading – Set meter at it’s highest setting to prevent blowing fuses – Conventional current flow – correct polarity

• Connect a temporary bond rated for the ampere measured • Normal practice for most static stray current locations– set up

a one ohm slide resister, with the setting half way (= .5 ohms) • Measure potentials @ maximum exposure area before and

after temporary connected

February 21-23, 2017 Mike Placzek – ARK Engineering 47

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 48: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Setting a Resistant Bond – Best Practice

• If potential shift over structure goes from a depressed state to an impressed state, resistance is too low

• If potential shift over structure is still in a depressed state, resistance is too high

• Keep adjusting slide resistance till desired criterion is met by checking maximum exposure area

• Interrupt the foreign line during the measuring the potentials to visualise the shift change and determined the depression or impression state

February 21-23, 2017 Mike Placzek – ARK Engineering 48

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 49: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

NiCad Wire used

Slide resister

Different Types of Resistant Interference Bonds

February 21-23, 2017 Mike Placzek – ARK Engineering 49

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 50: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 50

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Resister Wire Application

The amount of Resistance is made by the Length of the Wire.

Page 51: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 51

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Slide Resister Application

Page 52: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 52

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Disconnect Bond Wire for Amp Drain Reading

Page 53: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

February 21-23, 2017 Mike Placzek – ARK Engineering 53

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Shunt Resister

Page 54: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Installation of Anodes • Method is not preferred

– Due to large amount of current discharge normally consumes anode in rapid time frame, requiring regular replacement

– Must connect the anode bed into the test station box for amp drain measurements

– Decrease in amp drain measurements, may indicate depletion of anodes

– Galvanic anodes used (Magnesium) -∆E from anodes must be > + ∆E from

interference February 21-23, 2017 Mike Placzek – ARK Engineering 54

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 55: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Galvanic anodes used to drain current February 21-23, 2017 Mike Placzek – ARK Engineering 55

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 56: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Hydrogen Embrittlement

• Pick area needs to be lowered below –1.20 V CSE (polarized) due to possible coating disbondment from hydrogen build up and possible hydrogen embrittlement that can cause pipe failure

• Normal resolution to problem, after bond is set, high potentials exist, rehabilitate coating to increase resistance – Bond may need readjusting after completion of tasks

February 21-23, 2017 Mike Placzek – ARK Engineering 56

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 57: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Example 1

• With our rectifier “on” the pipe-to-soil potential for our line is -0.990

• Foreign pipeline has a pipe-to-soil potential of

-0.960 • Rectifier switched “off” • Our potential becomes more positive (-0.850) • Foreign pipeline becomes more negative (-0.980)

February 21-23, 2017 Mike Placzek – ARK Engineering 57

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 58: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

OUR GROUNDBED

OUR RECTIFIER

+

_

OUR LINE

FOREIGNLINE

STATION

Foreign Line Our Line

ON -0.960 V ON -0.990 V

OFF -0.980 V OFF -0.850 V

V + 0.020 V V -0.140 V February 21-23, 2017 Mike Placzek – ARK Engineering 58

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 59: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Conclusion

• Based on the recorded test data, our line is considered to be protected

• The potential on the foreign line decreased (became more positive) when are rectifier was

switched on • There is a possibility a holiday exists near the point of

crossing • The reduction is not sufficient to indicate loss of

protection, no corrective measures required

February 21-23, 2017 Mike Placzek – ARK Engineering 59

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 60: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Example 2

• With our rectifier “on” the pipe-to-soil potential for our line is –1.150

• Foreign pipeline has a pipe-to-soil potential of

-0.580 • Rectifier switched “off” • Our potential becomes more positive (-1.040) • Foreign pipeline becomes more negative (-0.880)

February 21-23, 2017 Mike Placzek – ARK Engineering 60

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 61: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

OUR GROUNDBED

OUR RECTIFIER

+

_

OUR LINE

FOREIGNLINE

STATION

Foreign LineON - 0.580OFF - 0.880 V + 0.300∆

Our LineON - 1.150OFF - 1.040 V - 0.110∆

February 21-23, 2017 Mike Placzek – ARK Engineering 61

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 62: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Conclusion

• Based on the recorded test data, our line is considered to be protected

• The potential on the foreign line decreased (became more positive) when our rectifier

was switched on • Need to set a resistance bond to bring the

foreign pipeline “ON” potential back to the “OFF” potential

February 21-23, 2017 Mike Placzek – ARK Engineering 62

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 63: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Negative Bond

A negative bond occurs when the interfering pipeline has a pipe to soil potential less negative than the desired potential of the interfered line. In this case, the interference cannot be solved with a bond

February 21-23, 2017 Mike Placzek – ARK Engineering 63

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 64: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

DOT • P/P - • DOT Part 192.465 (c) Critical Bonds

6 times each calendar year, not to exceed 2 ½ months Non-Critical Bonds once each calendar year, not to exceed 15

months

February 21-23, 2017 Mike Placzek – ARK Engineering 64

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 65: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

DOT

• DOT Part 192.473 (a). Each operator whose pipeline system is

subjected to stray currents shall have in effect a continuing program to minimize the detrimental effects of such currents.

February 21-23, 2017 Mike Placzek – ARK Engineering 65

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 66: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

What Defines a Critical Bond?

• Definition of Critical bond - where the pipeline is conducting current through the bond and the measured potentials with the bond disconnected create a difference below the operators chosen criterion

• DOT allows the operator to chose the CP criteria and what criteria's are considered a critical bond

• If potentials of the company pipeline is below the CP criteria (determined by the operator) due to interference of a foreign structure, then this should be considered as critical

February 21-23, 2017 Mike Placzek – ARK Engineering 66

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 67: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Annual Monitoring Best Practice

• Monitoring Bonds utilizing a diode or reverse current

switch: A pipe-to-soil potential reading Bond current measurement Test to ensure the blocking device is

operative

February 21-23, 2017 Mike Placzek – ARK Engineering 67

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 68: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

Annual Monitoring Best Practice

• Monitoring All other bonds: Pipe-to-soil potential of all structures

with the bond connected Pipe-to-soil potential of all structures

with the bond disconnected Measurement of the bond current Typically five readings obtained

February 21-23, 2017 Mike Placzek – ARK Engineering 68

2017 Underground Corrosion Short Course Intermediate Corrosion Course – Period 6

Page 69: Static Stray DC Current Interference Testingcorrosionshortcourse.com/2017 slides/2017 UCSC... · • Conventional current will flow - from positive to negative, – From the foreign

THE END!

February 21-23, 2017 Mike Placzek – ARK Engineering 69