StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The...

19
Invest in the future With proven performance Invest in StanLock

Transcript of StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The...

Page 1: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

Corporate Office 2625 NW Industrial Street, Portland, Oregon 97210 503-226-6971 or 1-800-321-9677 Fax 503-226-6976

StanLock Representative:

Invest in the future

With proven performance

Invest in StanLock

Page 2: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com

Introduction

The const ruct ion . . . i n d u s t r y , e c o n o m i c l a n d s c a p e s , a n d a rc h i t e c t u r a l

t a s t e s h a v e c h a n g e d a l o t i n t h e l a s t 5 0 y e a r s .

Technologies have come

and gone, as have entire

structures. To seal a

curtain wall against the

forces of nature, there is

only one product that has

stood these tests of time.

StanLock glazing gaskets

are preformed elastomeric

mechanical seals used to

attach glass to a supporting

framework of metal, concrete,

or other rigid construction

material. Since 1955,

StanLock has been one

of the most trusted and

reliable curtain wall glazing

systems in the industry.

Properly installed, it will keep

energy in, while keeping

the elements out.

Page 3: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

1griffithrubber.com

Curtain wall gasket systems provide much more than simple enclosure and protection; they must also function to control the environment within. The system must control solar radiation, temperature, and humidity in its functions as the outer envelope of a building. As a result of these factors, the glass is dynamic – it is always in motion. The very features that give the curtain wall its popularity – its sleek and thin profile combined with lightweight materials – have also contributed to the problems of providing for adequate weather seals. The seal must not only accommodate considerable movement between the panel or frame, but must also permit deflection under wind loads that would shatter a rigidly-held light of glass. StanLock Neoprene glazing gaskets offer an attractive, economical, and long lasting solution to the sealing problems of contemporary curtain wall design.

Benefits to StanLock glazing systems:

•StanLockisaZeroMaintenanceProduct: With over 50 years of in-field experience in all types of climates, StanLock is proven to last reliably.

•EnergyEfficient: StanLock provides a complete thermal break from the frame of the building and the glass, providing a highly efficient envelope.

•SupremeCondensationControl: No metal is exposed in a StanLock system, greatly reducing problems associated with condensation and drainage.

•NoFieldSplicingorWetSealant Joints: StanLock gaskets are precisely engineered and manufactured to your specifications from the factory, providing a seamless, custom-fit gasket that fits right every time.

•SuperiorVibrationandNoiseControl: StanLock’s gaskets dampen noise and vibration at a level that is far superior than a metal frame system. They absorb shocks, such as gale-force winds, high vibrations of jet planes, and earthquake racking, thus contributing to glass performance.

•OutstandingDeflectionPerformance: StanLock eliminates glass to metal contact during racking or movement. This allows the gasket sealing lip to stay in contact with the glass and assuring continuous sealing before, during and after movement.

•Exceptional,EnduringAppearance: StanLock gaskets provide a crisp, black design element. Made from neoprene, they are unaffected by ultraviolet light, salt, and other common environmental pollutants.

ConvertingABuilding

To convert a building to insulated glass is easier than ever. With simple aluminum adapters, a building that once used 1/4” glass can easily be transformed into an efficient, modern, and long lasting structure with the latest in insulated glass technologies. This can lead to lower energy costs, superior wind load performance, and possible energy related tax credits.

RequirementsforRetrofitting

StanLock is a zipper wall system, not unlike many older systems that are no longer manufactured. If your building was originally built using any zipper wall or lockstrip system, StanLock gaskets can easily and affordably provide you a retrofit solution when replacing broken glass, renovating or rehabilitating the building, or converting from a single pane system to insulated glass. Compatible brands and systems include: F.H. Maloney Gasket Systems, D.S. Brown, Chardon Rubber, Cadillac Rubber, Reed Rubber, Ball Brothers, and Wright Rubber. If you are unsure of compatibility, your StanLock representative can provide assistance to determine what profile will work for you.

Page 4: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com2 griffithrubber.com

* TiteLock–U.S. Patent Number 3,445,965

“H”TypeGasketsGlazing gaskets shaped like the letter “H” mount onto a flange (also called a “nib”) within a frame. The insertion of the locking strip effects a seal against both the frame and the glass (or panel).

This creates a precise balance of mechanical pressures and counter-pressures between the frame and the gasket, and also between the glass (or panel) and the gasket. For the corners of the gasket, Stanlock utilizes the exclusive TiteLock sealing lip to ensure maximum sealing pressure around the entire frame corner, while maintaining the conventional appearance of a molded gasket.

MetalNibRequirements

• Framedimensionsmaynotdeviate more than ± 1/16” from nominal.

• Thicknessoftheflangemustbewithin a tolerance of ± 1/32” at all points and height must provide a minimum of 1/8” from metal base.

• Thesurfaceofthemetalframesmust be in the same plane at all points.

• Metalmustbesmooth,burrandrust free, and be treated to resist oxidation.

• Cornersmustalsobesmooth,free of gaps, welds, and offsets.

• Metalcastinconcreteisacceptable as long as all tolerances are met.

ConcreteFrameRequirements

• Framedimensionsmaynotdeviate more than ± 1/8” from nominal.

• Minimumsizeofthenibis1”wideand 1” high.

• Contactsurfacemustbeplastersmooth, waterproofed, and on a plane.

• Nooffsettolerancesforcorners.• Someprecasttechniquesmay

require a draft on some surfaces, should be on top of nib and taper out.

• ConsultyourStanLockrepformore details about concrete nib tolerances and installation guidance.

Frame Requirements

SplineTypeGaskets Spline-type glazing gaskets are designed with a finned spline that fits into a preformed receiver groove. They are sometimes called “tongue-and-groove” gaskets. As with any other gasket design, spline-type gaskets seal by maintaining a precise balance of pressures between the frame and gasket and the glass (or panel) and gasket. The seal against the frame is effected by forcing the spline of the gasket into the groove so that

the side fins on the spline retain the gasket in the groove and thus hold it tightly against the frame surface. (Note that these side fins retain rather than seal.) The seal against the glass or panel in the spline-type of gasket is produced by inserting the lockstrip.

1/8"MIN.

+/- 1/32" TOLERANCE

MIN.HEIGHT

OF FLANGE

1/16"MAX.

1/4"MIN.

1" MIN. 1/16" MAX.1/16" MAX.

1/8" MAX.RADIUS

* "A

" D

IM. N

OM

. FR

AM

E SI

ZE

*

"B"

DIM

ENSI

ON

NO

MIN

AL

G

LASS

OR

PA

NEL

SIZ

E

“H” Type

* "

A"

DIM

. NO

M. F

RA

ME

SIZE

*

"B"

DIM

ENSI

ON

NO

MIN

AL

G

LASS

OR

PA

NEL

SIZ

E

Spline (groove) Type

Page 5: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com 3griffithrubber.com

1⁄4” to 1” Conversion Requirements

ConversiontoInsulatedGlass For many years it has been standard practice to install 1/4” single pane glass on most buildings. As glazing technology has improved and energy costs have risen, insulated glass has become more feasible and attractive for these existing structures. In order to take advantage of the many benefits of insulated glass in a cost effective manner, it is imperative to limit the impact on the building itself.

The installation of Stanlock to any existing curtain wall building will provide minimum disruption to the function of the building. The windows can be replaced, retrofitted, or installed without any significant work to the actual building itself.

Every conversion will be a bit unique to the building, but the premise is simple. With the modular nature of a StanLock system (it can be easily detached from the building), conversion is much easier than other systems. The key to this process is to install a simple aluminum adapter to support the additional weight of the insulated glass. As shown in Exhibit B. Your Stanlock representative can provide recommendations for aluminum manufacturers that specialize in these products and are familiar with the entire conversion process.

The graphic shown here is an example of the many conversion scenarios that are possible with our entire StanLock portfolio. Depending on the local climate of the building, this is one of the better investments that can be made to a building to not only increase its lifespan, but also immediately impact the daily costs of operations.

SL-2129GasketwithCF-787AluminumAdapter

Exihibit A, example of existing 1/4” glass system

Exihibit B, example of conversion to a 1” glass system with adapter.

Page 6: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com4 griffithrubber.com

FitandFunction

The purpose of a glazing gasket is to secure the glass to the structure while providing a sealed envelope of protection against the outside elements of nature. A zipper wall system provides the best of all worlds. It creates a complete thermal break, while allowing for easy installation and maintenance.

To attain the sealing pressures which are required to secure and seal panels to frames, StanLock gaskets are made in two parts: the gasket itself and a separate locking strip.

The lockstrip is harder in durometer than the gasket itself, allowing more pressure to be transmitted to the gasket’s sealing surfaces. To effect the seal, the locking strip is inserted progressively, with a special tool, into a groove that is manufactured into the gasket. This puts the entire gasket under sufficient compression to produce the required sealing pressure. Insertion of the locking strip resembles the action of a zipper, hence the term “zipper gasket” is sometimes used to describe this type of product.

StanLock systems can be set quickly and easily. The on-site cost of installing StanLock gaskets is especially low considering the low impact to the building during installation. Walls, ceilings, and other building systems can remain intact during installation, replacement, or retrofitting. This keeps an existing building in operation, or offers more timeline flexibility with new construction.

The greatest cost benefit, however, is a proven zero maintenance track record. No caulking, painting, or special cleaning is ever needed. If a glass or panel is broken, replacement is simply a matter of removing the lockstrip from the gasket, inserting the new glass or panel, and locking it back into place in the same gasket with a new lockstrip.

Field-testedforover60years

The exclusive Neoprene compound developed for StanLock gaskets has itself been proven by over a half century of use in building seals, and has been successfully used by architects in thousands of installations throughout the world.

StanLock gaskets seal against the elements - rain, snow, sleet and wind. They continue to function through wide temperature variations and compensate for thermal stresses. Most important of all, StanLock glazing gaskets withstand exposure to the elements with little or no deterioration.

Installation

ArchitecturalDesign

StanLock can be manufactured for any number of possible building elevations. Single punch out openings, simple cross members, and extensive ladder gaskets are all popular configurations. Gaskets may also be made for a radiused frame or in the shape of an arch, oval or circle.

Regardless of your needs, StanLock is a high-quality and custom manufactured product designed to your specifications.

SmallerApplicationsandRepairs

StanLock is also sold available in bulk footage for smaller applications and repairs. There are many advantages to this approach.

• Profilesandlockstriparemanufactured in 50 ft. rolls.

• Instockprofilesmeansyourordercan be shipped fast.

• Idealforsmallrepairs.• Buynowandusewhenneeded.• Gasketsaredesignedtohandle

most common glass and frame requirements.

• Excellentcostadvantageforsmall structures that can be engineered in the field.

Page 7: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com 5griffithrubber.com

Technical Information

WindLoad

A primary consideration in design of glazing gaskets is the maximum allowable size of frame opening that may be used. To establish this, StanLock has been rigorously subjected to wind load tests. Float glass was installed into openings of varying sizes, in a wind load test chamber with StanLock glaz-ing gaskets. Static pressures were applied to the point of failure. These test results form the basis for the wind load chart pictured below.

This chart is a modification of the familiar wind load charts for float glass as published by glass manufacturers. With respect to the thicknesses of float glass from 1/4” through 1” insulated glass with 1/4” lights, the blue lines in this chart are identical to those shown for conven-tional glazing in the glass manufac-turers’ charts. In these thicknesses, the test-to-failure established that the maximum allowable sizes for

Neoprene gasket glazing were significantly greater than indicated in the glass manufacturers’ charts. For 1/2” thick annealed float glass, the maximum allowable sizes of openings for gasket glazing are less than some industry charts. These smaller maximum sizes for these two thicknesses are as shown in the chart.

MaximumAllowableSizesforLadderGaskets

Wind velocity tests have shown that when a ladder-type gasket with unsupported muntins or mullions are mounted in a frame, the glazed unit has a resistance to blowout pressure substantially lower than the glass or panel when all in one piece instead of subdivided by muntins. Gasket designs, which have both vertical and horizontal muntins within the same frame opening, should have rigid structural backup support in at least one direction. Some muntins

have been developed with tieback supports that anchor the entire installation to structural members of the building. These increase the resistance to blowout pressure for the entire installation. Experience has shown that it is not practical to make, transport, or install a ladder type gasket that is more than 8’ x 20’. However, such units may be field joined into continuous walls of any length.

SizeLimitationsforOtherTypesofPanels

It should be emphasized that the maximum allowable sizes apply only to annealed glass (including heat absorbing types) used singly or in insulating glass units. • Insulatingglassunitsize

limitations are scaled from the chart by using a glass thickness 50% greater than the thickness of the individual glazed lights of the insulating unit. (Example: two 1/4” lights separated by 1/2” airspace. Find 1” insulated glass on W/L chart).

• Formaximumsizelimitationson other types of glass, and for various types of panels, consult your StanLock representative.

CalculatingDimensionsTo determine the nominal glass (or panel) size with rectangular openings for any perimeter gasket shown in this booklet, simply subtract the “W” factor indicated below the applicable section drawing from the “daylight” frame height and width. In any Neoprene gasket installation, there are two critical sets of dimensions. One set is for the frames; the other is for the glass (or panels) which are to be installed inside the frames.

Maximum glass area

recommended for glazing

with standard H-Type

lockstrip Gaskets without

reinforcement clips.

1" Insulated glass (with 1/4" lights)

1/2"

1/4"

Gla

ss A

rea

- sq.

ft

Load - lbs/sq. ft.

StanLock Wind Load Chart

Page 8: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com6 griffithrubber.com

Technical Information

FrameDimensionsFrame dimensions should be taken from the inner surfaces of the frame.

• For“H”-typegaskets,thismeasurement is taken from the top of the flange or nib.

• Forspline(orgroove)typegaskets, this measurement is taken from the surface (across the top) of the groove. This opening is shown as the “A” dimension in both diagrams on this page.

• Theseframedimensionsarecommonly called the “daylight” opening. The glass or panel dimension is referred to in the diagrams as the “B” dimension. It should be noted that the “A” and “B” dimensions are to be measured between two opposite sides of a frame as shown in the diagrams.

• Intheindividualgasketdrawingsin this catalog (pages 9 through 11) each gasket section is presented without showing the opposite side.

Glass(orpanel)Dimensions

The glass (or panel) that is to be set into a frame must be sufficiently smaller than the frame so that insertion will be possible. In order to compute any glass size for any corresponding frame size, a clearance factor (or “W” factor) must be used.

• Thisfactordependsonthegasketdesign and is listed in the catalog under every section drawing. To determine the required size of glass or panel for any given opening, subtract this “W”.

• Forcuttingglasstooddframeshapes (not rectangular) having straight sides, the “W” factor cannot be subtracted from one side but must be translated perpendicular to each side of the unit. The result is a reduction from frame to glass or panel of one-half of the “W” factor from each side.

AcceptableTolerances

• Accurateframedimensionsarealso the basis on which gaskets are produced properly to fit to the frames. Each gasket is made with a carefully computed oversize and is “crowded” when installed for proper functioning.

• Forthesereasons,anydeviationsfrom nominal dimensions must be held within the acceptable tolerances listed with every gasket section drawing in this catalog.

• Inaddition,itisimportanttocheck for any out of square condition, so as to cut the glass or panel to correspond with the frame. The measurements can be taken as shown in the diagram below. The maximum allowable differential is 1/8” between D1 and D2.

D 2

D 1

"A" DIM = NOM FRAME SIZE

GLASS OR PANEL SIZE"8" DIMENSION = NOMINAL

"X" d

imen

sion

"Y" d

imen

sion

"Z" d

imen

sion

NO

MIN

AL

GLA

SS

OR

PA

NE

L S

IZE

NO

MIN

AL

GLA

SS

OR

PA

NE

L S

IZE

NO

MIN

AL

GLA

SS

OR

PA

NE

L S

IZE

"A"

DIM

. = N

OM

. FR

AM

E S

IZE

. AC

CE

PTA

BLE

TO

L. =

1/1

6"

Dimensions

Requiredfor

Fabrication

ofGaskets

Page 9: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com 7griffithrubber.com

Gasket Profiles

SL-2043“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

5/8" MIN.

5/16"

5/16"

1/2"

1/4"±1/32"

13/16"

1/2" 3/8"

1/2"

3/8"

1/4"±1/32"

"A" D

IM.

(NO

M. F

R. S

IZE

+_

1/16

")"B

" DIM

.(N

OM

. GL.

* SIZ

E +

_ 1/

16")

5/16"

9/16"

5/16"

11/16" MIN

15/16"

1 3/8"

1/2"

1/4"

SL-2000“W” factor = 13/16”

1/4"±1/32"

5/16" 1/2"

"A" D

IM.

(NO

M. F

R. S

IZE

+_ 1

/16"

)

"B" D

IM.

(NO

M. G

L.* S

IZE

+_ 1

/16"

)

1 1/2"5/16"

9/16"

5/8"

3/8"

11/16"

1 3/16"

SL-2051“W” factor = 13/16”

1/4"±1/32"

"A" D

IM.

(NO

M. F

R. S

IZE

+_

1/16

")

"B" D

IM.

(NO

M. G

L.* S

IZE

+_

1/16

")

5/16"

9/16"

5/16" 3/8" 3/8"

11/16"MIN

1 1/16"

1 3/8"

1/2"

SL-2011“W” factor = 13/16”

SL-2127

15/16"

1/4"±1/32"

1/4"±1/32"

1/2"

1/2"

5/16" 3/8"

MUNTINOR MULLION

SL-2101“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16") 1/4"±1/32"

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

3/4" MIN.5/8"

5/16"

5/16"

9/16"

15/16"

1 3/8"

1/4" 3/8"

1/2"

SL-2064“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

5/8" MIN.

5/16"

1/2"

1/4"±1/32"

5/8" 3/8"

1/2"

5/16"

13/16"

SL-2071“W” factor = 13/16”

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/8"

)

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

3/4" MIN.

5/16"

5/16"

9/16"

1/4"±1/32"

17/16"

3/4"

17/16"

3/8"

9/16"

SL-2026“W” factor = 13/16”

5/16"

5/16"

1/2"13/16"

7/16"

1/2"

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/8"

)

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

3/4" MIN.

1/4"± 1/32"

1"± 1/32"

13/4"

1/4"±1/32"

1/8"1/2"

"A" D

IM.

(NO

M. F

R. S

IZE

+_

1/16

")

"B" D

IM.

(NO

M. G

L.* S

IZE

+_

1/16

")

1 5/16"5/16"

1/2"

1/2"

5/16"

5/8" MIN

15/16"

SL-2008“W” factor = 13/16”

1/4"±1/32"

3/16"7/16"

"A" D

IM.

(NO

M. F

R. S

IZE

+_ 1

/16"

)

"B" D

IM.

(NO

M. G

L.* S

IZE

+_ 1

/16"

)

1 5/16"

5/16"

1/2"

1/2"

5/16"

5/8" MIN

15/16"

SL-2036“W” factor = 13/16”

SL-2082

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

8")

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

3/8" 5/8" 1/2"

5/16"5/16"

5/8"

1/2"

1/4"± 1/32"

SL-2086

15/16"

1/4"±1/32"

1/4"±1/32"

1/2"

1/2"

5/16" 5/16"

5/16"

1/2"

1/2"

3/8" 1/8"

1 5/16"

1/4"

SL-2085RECOMMENDED FOR VERTICAL USE ONLY

1/4”GlassorPanelGasketProfiles

9/16 "

5/16 "1/4 "

3/8 "

1/2 "5/16 "

1/2 "

Stanlock 2055SL-2055

Page 10: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com8 griffithrubber.com

Gasket Profiles

3/8”GlassorPanelGasketProfiles

SL-2250“W” factor = 13/16”

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/16

") 3/8"±1/32"

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

11/16"MIN

5/16"

5/16"

1/2"

1 1/16"

1 3/8"

3/8" 3/8"

9/16"

SL-2252“W” factor = 13/16”

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/16

") 3/8"±1/32"

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

5/8"MIN

5/16"

5/16"

1/2"

1 1/16"

1 5/16"

1/4" 1/2"

1/2"

SL-2272

15/16 "

3/8"±1/32"

3/8"±1/32"

1/2"

1/2"

5/16" 3/8"

5/16"

SL-2300"W" factor = 13/4"

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

8")

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

3/8" 5/8" 1/2"

5/16"3/8"

5/8"

1 3/16"

9/16"

3/8"

15/16"

3/8"

1/2"

1/2"

5/16" 3/8"

SL-2272

5/16"

1/2"

1/2"

3/8" 1/8"

1 5/16"

3/8"

SL-2298RECOMMENDED FOR VERTICAL USE ONLY

1/2”GlassorPanelGasketProfiles

SL-2376“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

1/2"±1/32"

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

11/16"MIN

5/16"

5/16"

1/2"

1 1/16"

1 3/8"

1/2" 3/8"

9/16"

SL-2391RECOMMENDED FOR VERTICAL USE ONLY

1/2"±1/16"

5/16"3/4" 3/4"

13/32"

13/32"

SL-2392RECOMMENDED FOR VERTICAL USE ONLY

5/16"1/2" 1/2"

3/8"

5/16"

1/2" ± 1/32"

1/2"±1/32"

SL-2380“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

1/2"±1/32"

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16"±

3/1

6")

5/8"

5/16"

1 1/8"

9/16"

1/2 ± 1/32" 3/8"

5/16"

5/8”GlassorPanelGasketProfiles 3/4”GlassorPanelGasketProfile

SL-2580

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

3/4"±1/16"

"B" D

IM.

(NO

M. G

L. S

IZE

3/1

6± o

r -1/

16")

11/16"MIN

7/16" 7/16"

5/16"

13/16"

1 9/16"

1 11/16"

3/4"

9/16"weephole

Neoprenesetting blockSL-1017

W factor = 15/16" for width and 1 1/16" for heightSL-2480

W factor = 15/16" for width and 1 1/16" for height

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

5/8"±1/16"

"B" D

IM.

(NO

M. G

L. S

IZE

3/1

6± o

r -1/

16")

11/16"MIN

7/16"

5/16"

13/16"

1 7/16"

1 11/16"

5/8" 3/8"

9/16"weephole

Neoprenesetting blockSL-1014

SL-2481RECOMMENDED FOR VERTICAL USE ONLY

5/8"±1/16" 5/8"±1/16"

5/16"3/4"

1 13/16"

3/4"

13/32"

13/32"

SL-2580

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

3/4"±1/16"

"B" D

IM.

(NO

M. G

L. S

IZE

3/1

6± o

r -1/

16")

11/16"MIN

7/16" 7/16"

5/16"

13/16"

1 9/16"

1 11/16"

3/4"

9/16"weephole

Neoprenesetting blockSL-1017

W factor = 15/16" for width and 1 1/16" for heightSL-2480

W factor = 15/16" for width and 1 1/16" for height

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

5/8"±1/16"

"B" D

IM.

(NO

M. G

L. S

IZE

3/1

6± o

r -1/

16")

11/16"MIN

7/16"

5/16"

13/16"

1 7/16"

1 11/16"

5/8" 3/8"

9/16"weephole

Neoprenesetting blockSL-1014

SL-2481RECOMMENDED FOR VERTICAL USE ONLY

5/8"±1/16" 5/8"±1/16"

5/16"3/4"

1 13/16"

3/4"

13/32"

13/32"

SL-2580

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

3/4"±1/16"

"B" D

IM.

(NO

M. G

L. S

IZE

3/1

6± o

r -1/

16")

11/16"MIN

7/16" 7/16"

5/16"

13/16"

1 9/16"

1 11/16"

3/4"

9/16"weephole

Neoprenesetting blockSL-1017

W factor = 15/16" for width and 1 1/16" for heightSL-2480

W factor = 15/16" for width and 1 1/16" for height

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

5/8"±1/16"

"B" D

IM.

(NO

M. G

L. S

IZE

3/1

6± o

r -1/

16")

11/16"MIN

7/16"

5/16"

13/16"

1 7/16"

1 11/16"

5/8" 3/8"

9/16"weephole

Neoprenesetting blockSL-1014

SL-2481RECOMMENDED FOR VERTICAL USE ONLY

5/8"±1/16" 5/8"±1/16"

5/16"3/4"

1 13/16"

3/4"

13/32"

13/32"

SL-2250“W” factor = 13/16”

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/16

") 3/8"±1/32"

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

11/16"MIN

5/16"

5/16"

1/2"

1 1/16"

1 3/8"

3/8" 3/8"

9/16"

SL-2252“W” factor = 13/16”

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/16

") 3/8"±1/32"

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

5/8"MIN

5/16"

5/16"

1/2"

1 1/16"

1 5/16"

1/4" 1/2"

1/2"

SL-2272

15/16 "

3/8"±1/32"

3/8"±1/32"

1/2"

1/2"

5/16" 3/8"

5/16"

SL-2300"W" factor = 13/4"

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

8")

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

3/8" 5/8" 1/2"

5/16"3/8"

5/8"

1 3/16"

9/16"

3/8"

15/16"

3/8"

1/2"

1/2"

5/16" 3/8"

SL-2272

5/16"

1/2"

1/2"

3/8" 1/8"

1 5/16"

3/8"

SL-2298RECOMMENDED FOR VERTICAL USE ONLY

SL-2250“W” factor = 13/16”

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/16

") 3/8"±1/32"

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

11/16"MIN

5/16"

5/16"

1/2"

1 1/16"

1 3/8"

3/8" 3/8"

9/16"

SL-2252“W” factor = 13/16”

"A"

DIM

.(N

OM

. FR

. SIZ

E ±

1/16

") 3/8"±1/32"

"B"

DIM

.(N

OM

. GL.

SIZ

E ±

1/16

")

5/8"MIN

5/16"

5/16"

1/2"

1 1/16"

1 5/16"

1/4" 1/2"

1/2"

SL-2272

15/16 "

3/8"±1/32"

3/8"±1/32"

1/2"

1/2"

5/16" 3/8"

5/16"

SL-2300"W" factor = 13/4"

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

8")

"B" D

IM.

(NO

M. G

L. S

IZE

± 1/

16")

3/8" 5/8" 1/2"

5/16"3/8"

5/8"

1 3/16"

9/16"

3/8"

15/16"

3/8"

1/2"

1/2"

5/16" 3/8"

SL-2272

5/16"

1/2"

1/2"

3/8" 1/8"

1 5/16"

3/8"

SL-2298RECOMMENDED FOR VERTICAL USE ONLY

Page 11: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com 9griffithrubber.com

Gasket Profiles

1”GlassorPanelGasketProfiles

SL-2793“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

Neoprene settingblock SL-1000

1"± 1/16"

15/8"

7/8"

3/8"

5/16"

1/2"

1/2"

5/8"2"

SL-2791*U.S. Patent Number 3,866,374

1"±1/16"

2 3/4"

3/4"

3/4"

3/8"

3/8"

1/2"

7/16" 7/16"

SL-2778RECOMMENDED FOR VERTICAL USE ONLY

1"±

1/16

"

5/16"3/4"

1 13/16"

3/4"

1 13

/16"

7/16"

7/16"

SL-2752W factor = 15/16" for width and 1 1/16" for height

1"±1/16"

1 13/16"

"B" D

IM.

(NO

M. G

L. S

IZE

= +3

/16

or -1

/16"

)

"A" D

IM.

(NO

M. F

R. S

IZE

= ±

1/16

)

1"

9/16"

7/16"7/16"

1 11/16"

5/16"

13/16"

11/16" MIN

weephole

Neoprenesetting blockSL-1000

SL-2799W factor = 15/16" for width and 1 1/16" for height

5/8"±1/16"

"B" D

IM. =

NO

MIN

AL G

LASS

SIZ

E(A

CC

EPTA

BLE

TOL.

ON

"B" D

IM. =

3/

16±

or -1

/16"

)

"A" D

IM. =

NO

MIN

AL F

RAM

E SI

ZE(A

CC

EPTA

BLE

TOL.

ON

"A" D

IM. =

1/1

6±)

1" ± 1/32"

9/16"

1 1/8"

5/16"

13/16"

3/16"

3/4"

7/16"

weephole

Neoprenesetting blockSL-1000

SL-2787RECOMMENDED FOR VERTICAL USE ONLY

1"±

1/16

"

5/16"3/4"

1 13/16"

3/4"

3/8"

7/16"

SL-2782"W" factor = 1 3/4" for width and 13/4" for height

WEEP TO EXTERIOR

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

8")

7/8" 5/8" 1"

19/32"

3/8"

1 13/32"

1"± 7/16"7/16"

13/16"

"B" D

IM.

(NO

M. G

L. S

IZE

+ 3/

16" ±

1/1

6")

WEEP HOLE

Neoprene settingblock SL-1000

The gaskets shown to the right are intended to provide the full support required in applications

of vertically stacked insulating glass units.

SL-2793“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

Neoprene settingblock SL-1000

1"± 1/16"

15/8"

7/8"

3/8"

5/16"

1/2"

1/2"

5/8"2"

SL-2791*U.S. Patent Number 3,866,374

1"±1/16"

2 3/4"

3/4"

3/4"

3/8"

3/8"

1/2"

7/16" 7/16"

SL-2778RECOMMENDED FOR VERTICAL USE ONLY

1"±

1/16

"

5/16"3/4"

1 13/16"

3/4"

1 13

/16"

7/16"

7/16"

SL-2752W factor = 15/16" for width and 1 1/16" for height

1"±1/16"

1 13/16"

"B" D

IM.

(NO

M. G

L. S

IZE

= +3

/16

or -1

/16"

)

"A" D

IM.

(NO

M. F

R. S

IZE

= ±

1/16

)

1"

9/16"

7/16"7/16"

1 11/16"

5/16"

13/16"

11/16" MIN

weephole

Neoprenesetting blockSL-1000

SL-2799W factor = 15/16" for width and 1 1/16" for height

5/8"±1/16"

"B" D

IM. =

NO

MIN

AL G

LASS

SIZ

E(A

CC

EPTA

BLE

TOL.

ON

"B" D

IM. =

3/

16±

or -1

/16"

)

"A" D

IM. =

NO

MIN

AL F

RAM

E SI

ZE(A

CC

EPTA

BLE

TOL.

ON

"A" D

IM. =

1/1

6±)

1" ± 1/32"

9/16"

1 1/8"

5/16"

13/16"

3/16"

3/4"

7/16"

weephole

Neoprenesetting blockSL-1000

SL-2787RECOMMENDED FOR VERTICAL USE ONLY

1"±

1/16

"

5/16"3/4"

1 13/16"

3/4"

3/8"

7/16"

SL-2782"W" factor = 1 3/4" for width and 13/4" for height

WEEP TO EXTERIOR

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

8")

7/8" 5/8" 1"

19/32"

3/8"

1 13/32"

1"± 7/16"7/16"

13/16"

"B" D

IM.

(NO

M. G

L. S

IZE

+ 3/

16" ±

1/1

6")

WEEP HOLE

Neoprene settingblock SL-1000

SL-2793“W” factor = 13/16”

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

16")

Neoprene settingblock SL-1000

1"± 1/16"

15/8"

7/8"

3/8"

5/16"

1/2"

1/2"

5/8"2"

SL-2791*U.S. Patent Number 3,866,374

1"±1/16"

2 3/4"

3/4"

3/4"

3/8"

3/8"

1/2"

7/16" 7/16"

SL-2778RECOMMENDED FOR VERTICAL USE ONLY

1"±

1/16

"

5/16"3/4"

1 13/16"

3/4"

1 13

/16"

7/16"

7/16"

SL-2752W factor = 15/16" for width and 1 1/16" for height

1"±1/16"

1 13/16"

"B" D

IM.

(NO

M. G

L. S

IZE

= +3

/16

or -1

/16"

)

"A" D

IM.

(NO

M. F

R. S

IZE

= ±

1/16

)

1"

9/16"

7/16"7/16"

1 11/16"

5/16"

13/16"

11/16" MIN

weephole

Neoprenesetting blockSL-1000

SL-2799W factor = 15/16" for width and 1 1/16" for height

5/8"±1/16"

"B" D

IM. =

NO

MIN

AL G

LASS

SIZ

E(A

CC

EPTA

BLE

TOL.

ON

"B" D

IM. =

3/

16±

or -1

/16"

)

"A" D

IM. =

NO

MIN

AL F

RAM

E SI

ZE(A

CC

EPTA

BLE

TOL.

ON

"A" D

IM. =

1/1

6±)

1" ± 1/32"

9/16"

1 1/8"

5/16"

13/16"

3/16"

3/4"

7/16"

weephole

Neoprenesetting blockSL-1000

SL-2787RECOMMENDED FOR VERTICAL USE ONLY

1"±

1/16

"

5/16"3/4"

1 13/16"

3/4"

3/8"

7/16"

SL-2782"W" factor = 1 3/4" for width and 13/4" for height

WEEP TO EXTERIOR

"A" D

IM.

(NO

M. F

R. S

IZE

± 1/

8")

7/8" 5/8" 1"

19/32"

3/8"

1 13/32"

1"± 7/16"7/16"

13/16"

"B" D

IM.

(NO

M. G

L. S

IZE

+ 3/

16" ±

1/1

6")

WEEP HOLE

Neoprene settingblock SL-1000

Page 12: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com10 griffithrubber.com

Curtain Wall

SL-2129

SL-2129SL-2129

For additional information on these systems contact your nearest StanLock Representative (See listing - back cover).

SL-2130SL-2128

SL-2822SL-2822

SL-2131

SL-2129

SL-2824

SL-2824

SL-2824

SL-2778

SL-2778

SL-2752

SL-2752

SL-2752

StanLock Hi-Rise System StanLock High PerformanceHi-Rise System(Not To Scale)1" vision

1" and / or 1/4" Spandrels

VISION VISION

SPANDREL SPANDREL

VISION VISION

VISION VISION

SL-2778

Page 13: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com 11griffithrubber.com

Setting & Spacer Strips

NeopreneSettingStrips(85± 5 Durometer) supplied only in 100ft continous rolls

NeopreneFillerandSpacerStrips(75± 5 Durometer) supplied only in 100ft continous rolls

SL-10021/4"

1/8"

SL-1019

1/8"

1/2"

SL-1005

1/8"

3/8"

SL-10241/4"

1/4"

SL-10255/16"

1/4"

SL-10063/8"

1/4"

SL-10081/2"

1/4"

SL-10139/16"

1/4"

SL-1023

3/8"

1/2"

SL-1020

13/32"

9/16"

SL-1116

9/16"

9/16"

SL-1118

5/8"

3/4"

SL-1114

3/4"

3/4"

SL-1115

3/4"

13/16"

SL-1021

3/16"

1/2"

SL-1014

3/16"

5/8"

SL-1017

3/16"

3/4"

SL-1003

3/16"

7/8"

SL-1000

3/16"

1"

SL-1010

1/4"

1"

SL-1028

3/8"

3/4"

SL-1027

1/4"

13/16"

SL-1001

3/8"

1"

SL-1117

3/4"

1 1/4"

SL-10111"

1/8"

SL-10151 11/16"

1/8"

SL-10291 1/4"

3/16"

SL-10161 1/4"

1/4"

SL-10021/4"

1/8"

SL-1019

1/8"

1/2"

SL-1005

1/8"

3/8"

SL-10241/4"

1/4"

SL-10255/16"

1/4"

SL-10063/8"

1/4"

SL-10081/2"

1/4"

SL-10139/16"

1/4"

SL-1023

3/8"

1/2"

SL-1020

13/32"

9/16"

SL-1116

9/16"

9/16"

SL-1118

5/8"

3/4"

SL-1114

3/4"

3/4"

SL-1115

3/4"

13/16"

SL-1021

3/16"

1/2"

SL-1014

3/16"

5/8"

SL-1017

3/16"

3/4"

SL-1003

3/16"

7/8"

SL-1000

3/16"

1"

SL-1010

1/4"

1"

SL-1028

3/8"

3/4"

SL-1027

1/4"

13/16"

SL-1001

3/8"

1"

SL-1117

3/4"

1 1/4"

SL-10111"

1/8"

SL-10151 11/16"

1/8"

SL-10291 1/4"

3/16"

SL-10161 1/4"

1/4"

SL-10021/4"

1/8"

SL-1019

1/8"

1/2"

SL-1005

1/8"

3/8"

SL-10241/4"

1/4"

SL-10255/16"

1/4"

SL-10063/8"

1/4"

SL-10081/2"

1/4"

SL-10139/16"

1/4"

SL-1023

3/8"

1/2"

SL-1020

13/32"

9/16"

SL-1116

9/16"

9/16"

SL-1118

5/8"

3/4"

SL-1114

3/4"

3/4"

SL-1115

3/4"

13/16"

SL-1021

3/16"

1/2"

SL-1014

3/16"

5/8"

SL-1017

3/16"

3/4"

SL-1003

3/16"

7/8"

SL-1000

3/16"

1"

SL-1010

1/4"

1"

SL-1028

3/8"

3/4"

SL-1027

1/4"

13/16"

SL-1001

3/8"

1"

SL-1117

3/4"

1 1/4"

SL-10111"

1/8"

SL-10151 11/16"

1/8"

SL-10291 1/4"

3/16"

SL-10161 1/4"

1/4"

SL-10021/4"

1/8"

SL-1019

1/8"

1/2"

SL-1005

1/8"

3/8"

SL-10241/4"

1/4"

SL-10255/16"

1/4"

SL-10063/8"

1/4"

SL-10081/2"

1/4"

SL-10139/16"

1/4"

SL-1023

3/8"

1/2"

SL-1020

13/32"

9/16"

SL-1116

9/16"

9/16"

SL-1118

5/8"

3/4"

SL-1114

3/4"

3/4"

SL-1115

3/4"

13/16"

SL-1021

3/16"

1/2"

SL-1014

3/16"

5/8"

SL-1017

3/16"

3/4"

SL-1003

3/16"

7/8"

SL-1000

3/16"

1"

SL-1010

1/4"

1"

SL-1028

3/8"

3/4"

SL-1027

1/4"

13/16"

SL-1001

3/8"

1"

SL-1117

3/4"

1 1/4"

SL-10111"

1/8"

SL-10151 11/16"

1/8"

SL-10291 1/4"

3/16"

SL-10161 1/4"

1/4"

Page 14: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com12 griffithrubber.com

SL-2813RECOMMENDED FOR VERTICAL USE ONLY

.687

.375

.687

SL-2123

.375

.250

.562

.562

SL-2124

.375

.562

.562

.405.375

SL-2814

.750

.500

.375

.750

.375

SL-2812

.405

.688

.375

.750

1.00 .378 DesignedSpecificallyforSmallBuildings

•Offtheshelfdelivery

•Easylockstripgasketinstallation

•Lowerinstalledcost

•Manycrosssectionsavailable

This StanLock system consists of lockstrip glazing gaskets

designed to handle most common glass and frame

requirements. This solid glazing system seals better and

requires practically no maintenance. It installs easier and

at a lower cost than traditional fluid glazing. The lockstrip

gaskets are conveniently packaged 50 feet/carton.

Field Fabrication

Page 15: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com 13griffithrubber.com

Muntin or Mullion

DimensionsforMuntinorMullionApplications

Perimeter SectionPart Number

SL-2000SL-2000SL-2018SL-2101SL-2011SL-2082SL-2082SL-2026SL-2068SL-2252SL-2250SL-2300SL-2300SL-2376SL-2380SL-2480SL-2782SL-2782SL-2752SL-2752SL-2752SL-2128SL-2752SL-2803

Muntin Sections

SL-2055SL-2085SL-2055SL-2055SL-2085SL-2086SL-2085SL-2086SL-2092SL-2272SL-2272SL-2272SL-2298SL-2392SL-2391SL-2481SL-2787SL-2800SL-2778SL-2800SL-2129SL-2130SL-2791SL-2803

Factor“X”

5/8”5/8”5/8”5/8”

9/16”15/16”15/16”9/16”5/8”5/8”5/8”

15/16”15/16”5/8”3/4”3/4”

1-1/8”1-1/8”7/8”7/8”7/8”5/8”

1-1/4”N/A

Factor“Y”

7/16”7/16”7/16”7/16”3/8”

7/16”7/16”3/8”

7/16”7/16”7/16”7/16”7/16”7/16”5/8”5/8”5/8”5/8”5/8”5/8”5/8”

7/16”1-9/16”

2-13/16”

These factors are based upon frame and glass tolerances as specified with each gasket section illustrated. When the specified tolerances are not maintained, the factors shown may not apply.

These factors do not allow for the use of setting blocks. When setting blocks are used, the appropriate height dimensions should be reduced by an amount equal to the setting block thickness.

Insulating glass should not be stacked vertically without proper structural support under each glass unit.

Factor“Z”

5/8”5/8”5/8”5/8”

9/16”15/16”15/16”9/16”5/8”5/8”5/8”

15/16”15/16”

5/8”3/4”3/4”

1-1/8”1-1/8”7/8”7/8”7/8”5/8”

1-1/4”N/A

Mockup installation desirableExperience has indicated that a glazed mockup of a typical frame opening is highly desirable in order to confirm proper glass sizes and eliminate any potential complication. This simple check can be accomplished by using any rigid panel such as plywood of the proper thickness.

Where muntin (or mullion) gaskets are specified, the frame dimensions are computed from the inside of the frame (as in a single frame) to the centerline of each muntin (or mullion) gasket.

• Inplaceofthe“W”factorgivenwitheachsection,special muntin (or mullion) factors have been computed. These are referred to as “X”, “Y” and “Z” factors. These factors for the sections having muntins (or mullions) appear in table below.

• Todeterminetheglassorpanelsizeforeachsection,the only step required is to subtract the “X”, “Y” or “Z” factors from the respective “X”, “Y” or “Z” dimensions.

• Forthesidehavingnomuntin(ormullion)computeglass or panel size by subtracting the “W” factor from the frame size or “A” dimension. (See bottom portion of diagram at right.) from the frame size or “A” dimension. (See bottom portion of diagram at right.)

Page 16: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com14 griffithrubber.com

Heavy Duty Installation Tool (12224SL)

A newly designed installation tool makes the lock strip easier to install than any other installation tool tested by StanLock engineers. Comparative time studies made with the new StanLock tool have established an average saving in labor time of up to 20%, as compared to previous StanLock tools.

Adapter Handle (12228SL)

StanLock offers an adapter handle which doubles the manual “zipping” power by turning the new tool into a two-handed operation. The adapter is affixed to the tool at any angle or position required for maximum push pressure.

Spatulas (12229SL)

StanLock also supplies an exclusive spatula. These are used in pairs to open the gasket lips to insert glass.

Installation Tools & Lubrication Products

StanLock Lubricant12219SL (one gallon)12219BSL (5-gallon pail)

StanLock lubricant, applied to the locking channel, greatly improves the ease of inserting lock strips. Being a clear-amber heavy liquid, it will not flow out from the channel at the top and sides when applied.

It also greatly facilitates the installation of glass or a panel into the gasket.

All the components of StanLock lubricant are readily water soluble and will wash off in the rain. If inside glazed, the gasket can be wiped clean with a cloth, either wet or dry.

StanLock lubricant contains no solvent which could deteriorate the gaskets or cause staining of concrete, aluminum or other light-colored surfaces.

Page 17: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

griffithrubber.com 15griffithrubber.com

The Neoprene compound used in StanLock gaskets possesses the necessary physical properties to provide resilience in the sealing lips of the gaskets and, at the same time, to offer resistance to sunlight, ozone, and fire. This compound meets and exceeds test requirements established for glazing gaskets by The American Society for Testing and Materials (ASTM). (See

table below.) For example, The StanLock Compound substantially exceeds ASTM C-542 test requirements for tensile strength, elongation at rupture and compression set. These properties indicate characteristics that are most desirable in glazing gaskets and which produce the optimum amount of resilience and resistance to even the

harshest of environments.

Neoprene Compound

(a) If a separate stock is used for the locking strip, it may have a hardness of 80 ± 5 durometer points and a minimum tensile strength of 1800 psi (12.5 MPa). In all other respects, it must meet these specifications.

Physical properties of StanLock Neoprene gaskets

Property Requirements Test Method

Tensile strength, mina 2000 psi (14MPa) D412

Elongation at rupture, min, percent 175 D412

Tear resistance, min 120 lb/linear in. D624 (Die C) (214 N/linear cm)

Hardness, durometer Aa 75 ± 5 D676

Compression set, max, percent, 22 h at 35 D395 (Method B) 212 F (100 C)

Brittleness temperature, min -40 F (-40 C) D746

Ozone resistance, 1 ppm

100 h at 100 F (37.7 C), 20 percent elongation no cracks D1149

Heat aging, 70 h at 212 F (100 C) +10-0 durometer D573 Change in hardness, max points

Loss in tensile strength, max, percent 15 Loss in elongation, max, percent 40

Flame resistance gaskets must not C-542 propagate flame

Page 18: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

STANLOCK GASKET PRODUCTLIMITED WARRANTY

Seller warrants, to the original purchaser only, that all products manufactured by seller (“Product”) are free from defects in material and workmanship under normal use and when properly installed for a period five (5) years from the date of delivery to the original purchaser. Any defective product shall be returned to seller’s factory, with transportation charges or duties to be paid by purchaser. Seller shall examine the product and determine to its satisfaction that the product is indeed defective. Upon such determination, Seller’s liability shall be limited to replacement of the defective product, and under no circumstances shall seller be liable for special, indirect or consequential damages. This limited warranty shall be the exclusive remedy for such defects in material or workmanship. Purchaser hereby waives all other remedies arising by law or otherwise. Seller does not warrant the product to meet the requirements of the safety code of any state, municipality or other jurisdiction, and purchaser assumes all risk and liability whatsoever resulting from the use thereof, whether used singularly or in combination with other product, equipment, machines or apparatus. This Limited Warranty shall not apply to any product which shall have been altered outside of seller’s factory or which has been subject to misuse, negligence or accident, or which has not been fitted and/or installed in compliance with seller’s written instructions. Seller neither assumes nor authorizes any person to assume for it any other liability in connection with its product. This warranty is the only warranty applicable to seller’s product. There are no warranties which extend beyond the description on the face hereof.

All other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose are hereby disclaimed.

Purchaser acknowledges that it is not relying on seller’s skill or judgement to select or furnish goods suitable for any particular purpose and that there are not warranties which extend beyond the description included herein.

griffithrubber.com16

Page 19: StanLock Representative - Griffith Rubber Mills Catalog 2010.pdf · Introduction The construction... ... contemporary curtain wall design. Benefits to StanLock ... Stanlock representative

Corporate Office 2625 NW Industrial Street, Portland, Oregon 97210 503-226-6971 or 1-800-321-9677 Fax 503-226-6976

StanLock Representative:

Invest in the future

With proven performance

Invest in StanLock