Standard Rung
30mm
385mm
350mm
10mm
111mm
2mm 47mm 77mm 107mm 147mm 177mm 207mm 236mm 272mm 302mm 332mm 355mm 378mm
![Page 2: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/2.jpg)
Top Rung Down
140mm
154mm 54mm
68mm
135mm
We need 8 or 9 of these made from standard rungs
![Page 3: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/3.jpg)
Second Rung
194mm10mm
2mm
We need 16 of these made from standard rungs
![Page 4: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/4.jpg)
Half Rung Up
154mm 54mm
We will have to machine these from the current half up types if they have been made in sufficient numbers we need 8 or 9
![Page 5: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/5.jpg)
Half Rung Down These may well have been made already we need 8 or 9
![Page 6: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/6.jpg)
data
30mm 36mm 215mm 394mm 573mm 752mm 931mm 1110mm 1289mm
Down Type Column
6mm52mm
HRD 2ndStd TRD
![Page 7: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/7.jpg)
data
30mm
Up Type Column
52mm 7mm
82mm 261mm 440mm 619mm 798mm 977mm 1156mm 1335mm
2ndStd HRU
![Page 8: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/8.jpg)
End Pieces
![Page 9: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/9.jpg)
Card Layout
30mm
20mm
100mm
3mm
24mm
3mm
90mm
90mm
10mm
23mm
30mm
423mm
HPDs
Level-0
Fibre Channel
Low Voltage
High Voltage
![Page 10: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/10.jpg)
Voltage solution
HV power out of column with minimum of bending
Other Cables can make S bend reasonably easily
For columns close to top of crate
HPDs
![Page 11: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/11.jpg)
End Pieces Voltage solution
HV powerLV power
HV mon
LV monSi Bias
![Page 12: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/12.jpg)
Voltage solution
All cables can exit form the back of the column if there is the space available
For columns far from the top of crate
This also allows the voltage patch panel to be in line with the cable port in the shield
![Page 13: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/13.jpg)
Low Voltage Power
![Page 14: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/14.jpg)
Low Voltage Sense
Two 2 pin lemo cables – with approximately cat5 thickness and stiffness
![Page 15: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/15.jpg)
High Voltage Power
Have to redesign end piece to allow these very thick cables to exit column satisfactorily. Can unbolt from patch panel and feed through so not too much compliance required.
![Page 16: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/16.jpg)
HV monitoring
Goes to one 15pin sub D – may be a problem with different lengths of cables
![Page 17: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/17.jpg)
Silicon Bias
A single lemo cable – Can it come from the C board?
![Page 18: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/18.jpg)
SPECS/ECS
Single RJ45 Network Cable
![Page 19: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/19.jpg)
Temperature Monitoring
Flat cable going to 37pin Sub-D
![Page 20: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/20.jpg)
Data Fibres
24 Fibres going to 2 break out boxes. Need to be careful of bending just after boxes. Need to be very careful of loop. Spare fibres go down front U channel by HPDs.
Concerned about space for loop before patch panel.
Doesn't show looping round the Lo boards to use uip fibre length
![Page 21: Standard Rung 30mm 385mm 350mm 10mm 111mm 2mm47mm77mm107mm 147mm177mm207mm 236mm272mm302mm332mm355mm 378mm.](https://reader036.fdocuments.us/reader036/viewer/2022062714/56649d5d5503460f94a3ce82/html5/thumbnails/21.jpg)
TTC Fibres