Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance...

7

Transcript of Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance...

Page 1: Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance Milli-ohms Female Terminal Type Battery Weight Outline Dimensions Battery Model 10hour
Page 2: Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance Milli-ohms Female Terminal Type Battery Weight Outline Dimensions Battery Model 10hour

Quality manufacturing processes for the front access T Range batteries incorporate the industry’s most advanced technologies including: an automated sealing detection system, a computer controlled “fill by weight” acid filler, and a temperature controlled water bath formation process. Each and every unit is capacity tested.

Thick positive plate design for maximum service float

life -12 year design life @ 20˚C(68˚F).

UL Recognized component . Valve regulated lead acid battery (VRLA). High-Compression Absorbed Glass Mat technology

(AGM) for greater than 99% recombination efficiency. Operates at a low internal pressure. Heavy duty threaded copper alloy terminals for ease of

assembly, reduced maintenance and increased safety. Advanced lead tin calcium alloy, reduces grid corrosion

and promotes long battery life. Standard: Reinforced ABS (UL 94HB) container and cover Optional: Flame-retardant reinforced ABS case and cover compliant with U.L.94 V-0 with an Oxygen Limiting Index of greater than 28%.

Over-sized, through the partition inter-cell welds provide low resistance connections, with minimal power loss.

Flame arresting, low pressure safety release venting system for individual cells, recognized per U.L. 924.

Multi-cell design for ease of installation and maintenance.

Horizontal or vertical operation.

Front access T range batteries Incorporate EverExceed’s advanced VRLA technology designed for long life and high performance in: Telecommunications Electric Utility

Distributed Power Wireless \ PCS Cellular Radio Microwave Broadband Switchgear Control Power

Communications

Surface transport. Classified as non-hazardous material

as related to DOT-CFR Title 49 parts 171-189.

aterial

Marine transport. Classified as non-hazardous mas per IMDG amendment 27.

Air transport. Complies with IATA/ICAO, Special

UL Compliant TESTED IN ACCORDANCE WITH NEBS Compliant BS 6290 PART 4 EUROBAT,10 year Bellcore, TR-NWT-000766

ANSI, TI: 330 plus classification

provision A67.

Page 3: Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance Milli-ohms Female Terminal Type Battery Weight Outline Dimensions Battery Model 10hour

CONSTRUCTION - EverExceed’s front access T Range AGM battery construction is as shown in the diagram below. The positive and negative grids are cast from a calcium / tin lead alloy to reduce grid growth and corrosion. The active material is manufactured from high purity lead (99.9999%) to minimize the negative effects of impurities. Separator is mat of random woven acid resistant glass fibres, which acts as sponge - soaking up and immobilizing the electrolyte whilst maintaining good acid to plate contact and availability during discharge. “U wrapping” is employed to eliminate the risk of short circuits due to mossing and debris at the bottom of the cell. The purpose of the separator is to maintain a constant distance between the positive and negative plates, thus removing the possibility of short circuits whilst allowing the active material to fully react with the electrolyte. The random weaving also results in an open structure, which offers minimal resistance to the flow of electrolyte during filling.

Plates: calcium / tin lead alloy, optimized for high corrosion resistance

Separator: Highly porous glass micro-fibre separator, optimized for low internal resistance, for maximum Absorption of the electrolyte and for electrical separation

Standard Housing: Reinforced ABS (UL 94HB) container and cover

Optional Housing: Flame-retardant reinforced ABS container and cover compliant with U.L.94 V-0 with an Oxygen limiting Index of greater than 28%.

Terminals: Silver plated Copper female insert for easy and safe assembly and maintenance free connection with excellent conductivity

Valves: Release gas in case of excess pressure and protects the cell against atmospher

ELECTROLYTE FILLING - Special production and stringent QC systems are utilized to ensure the electrolyte saturation is optimized for each cell. Measured high vacuum acid fill, reduces electrical variability between cells. The battery design and construction negates the need for electrolyte addition and the battery remains maintenance free throughout its design life.

SAFETY RELEAST VALVE - The battery will operate above atmospheric pressure under normal operating conditions, however the maximum pressure is governed by the safety one-way release valve. Open is activated by pressures in excess of approx. 2 PSI (14 Kpa), resealing at approx 1.2 PSI (8.4Kpa). GAS RECOMBINATION - The gasses generated during normal operation of the battery are internally recombined. In fact more than 99% of the gas achieves recombination. TERMINAL CONSTRUCTION -The contact quality between the insert terminal and the lead post is of vital importance during short duration /

high Amp discharges. Elevated terminal temperatures are the result of poor contact, eventually causing seal degradation and electrolyte leaks. EverExceed’s design and assembly technique for terminal casting ensures trouble free operation for the design life of the batt

Page 4: Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance Milli-ohms Female Terminal Type Battery Weight Outline Dimensions Battery Model 10hour

T-Range Electrical Specifications & Dimensions

12 year Grid plate Monobloc battery Nominal capacity design life 55 - 155Ah

Deep discharge Maintenance free Recyclable Valve regulated recovery lead - acid

Float Voltage & charging Constant Voltage charging is recommended

Recommended float voltage: 2.27VPC @ 20ºC(68ºF) Float Voltage Range: 2.25VPC to 2.30 VPC @ 20ºC(68ºF)

Equalize voltage: 2.35VPC for 24 Hours

Max.

Capacity (Ah) @20ºC dis. current IEC896-2 (A)

Internal Resistance Milli-ohms

Female Terminal Type

Battery Weight Outline Dimensions

Battery Model

10hour 8hour 1hour Length Width Height 1.80VPC 1.75VPC

1.67VPC Kg Lbs mm inch mm inch mm inch

T12V55 56.1 55.3 32.7 1050 4.5 F-M6 18.0 39.6 280 11.02 105 4.13 225 8.86

T12V80 81.5 80.4 47.5 1500 3.7 F-M6 26.0 57.2 560 22.05 113 4.45 190 7.48

T12V100 102 100 59.3 1600 3.2 F-M6 34.0 74.8 395 15.55 110 4.33 285 11.2

T12V110 111 110 64.7 1750 3.2 F-M6 36.0 74.8 395 15.55 110 4.33 285 11.2

T12V125 131 130 76.6 1900 2.9 F-M8 41.0 90.2 550 21.65 110 4.33 285 11.2

T12V155 157 155 91.4 2350 2.6 F-M8 48.0 106 550 21.65 110 4.33 285 11.2

Page 5: Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance Milli-ohms Female Terminal Type Battery Weight Outline Dimensions Battery Model 10hour

EverExceed AGM Front Access T Range VRLA Discharge Ampere Hour Data @ 20ºC (68ºF)

Actual battery performance data may be±5% of figures shown above

EverExceed AGM Front Access T Range VRLA Discharge Amperes Data @ 20ºC (68ºF)

Actual battery performance data may be±5% of figures shown above

Discharge Data Ampere Hours @ 20ºC Battery Model

End VPC

Discharge Data Amps @ 20ºC Discharge Time In Minutes End

VPC Discharge Time In Hours 5 10 15 30 45 60 1.5 2 3 4 5 8 10 12 20 24 1.80 136 101 80.5 51.3 38.3 31.7 1.85 37.6 40.3 43.0 45.0 46.6 50.9 53.0 54.1 58.9 59.8 T12V55 1.75 157 114 87.0 53.1 39.5 32.5 1.80 39.9 42.7 45.6 47.8 49.5 53.9 56.1 57.2 62.2 63.1 1.67 169 124 91.4 54.3 39.7 32.7 1.75 40.9 43.8 46.8 49.0 50.7 55.3 57.6 58.8 64.0 65.0 1.80 198 147 116 74.6 55.7 46.0 1.85 54.7 58.5 62.5 65.5 67.8 73.9 77.0 78.5 85.6 86.8 T12V80 1.75 228 165 126 77.2 57.4 47.2 1.80 58.0 62.1 66.3 69.4 71.9 78.3 81.5 83.1 90.4 91.7 1.67 245 180 133 78.9 57.7 47.5 1.75 59.4 63.6 68.0 71.1 73.7 80.4 83.7 85.4 93.0 94.4 1.80 247 184 145 93.0 69.5 57.4 1.85 68.2 73.0 78.0 81.6 84.5 92.2 96.0 98.0 107 108 T12V100 1.75 284 206 158 96.3 71.6 58.9 1.80 72.3 77.4 82.7 86.6 89.7 97.7 102 104 113 114 1.67 306 224 166 98.4 71.9 59.3 1.75 74.1 79.3 84.8 88.7 91.9 100 104 106 116 118 1.80 270 201 159 102 76.0 62.8 1.85 74.5 79.7 85.3 89.3 92.4 101 105 107 116 118 T12V110 1.75 310 225 172 105 78.3 64.3 1.80 79.1 84.6 90.4 94.6 98.0 107 111 113 124 125 1.67 334 245 181 108 78.6 64.7 1.75 81.0 86.7 92.6 97.0 100 110 114 116 127 129 1.80 319 238 188 120 89.8 74.3 1.85 88.2 94.4 101 106 109 119 124 127 138 140 T12V125 1.75 367 266 204 124 92.6 76.1 1.80 93.5 100 107 112 116 126 131 134 146 148 1.67 396 290 214 127 93.0 76.6 1.75 95.9 103 110 115 119 130 135 138 150 152 1.80 381 284 224 144 107 88.6 1.85 105 113 120 126 130 142 148 151 165 167

1.75 438 318 243 149 111 90.8 1.80 112 119 128 134 138 151 157 160 174 176 T12V155

1.67 472 346 256 152 111 91.4 1.75 114 122 131 137 142 155 161 164 179 182

Discharge Data Amps @ 20ºC Battery Model

End VPC

Discharge Data Amps @ 20ºC Discharge Time In Minutes

End VPC Discharge Time In Hours

5 10 15 30 45 60 1.5 2 3 4 5 8 10 12 20 24 1.80 136 101 80.5 51.3 38.3 31.7 1.85 25.1 20.1 14.3 11.3 9.33 6.36 5.30 4.50 2.94 2.49 T12V55 1.75 157 114 87.0 53.1 39.5 32.5 1.80 26.6 21.4 15.2 11.9 9.89 6.74 5.61 4.76 3.11 2.63 1.67 169 124 91.4 54.3 39.7 32.7 1.75 27.3 21.9 15.6 12.2 10.1 6.91 5.76 4.90 3.20 2.71 1.80 198 147 116 74.6 55.7 46.0 1.85 36.4 29.3 20.8 16.4 13.6 9.24 7.70 6.55 4.28 3.62 T12V80 1. 75 228 165 126 77.2 57.4 47.2 1.80 38.7 31.0 22.1 17.4 14.4 9.79 8.15 6.92 4.52 3.82 1.67 245 180 133 78.9 57.7 47.5 1.75 39.6 31.8 22.7 17.8 14.7 10.0 8.37 7.11 4.65 3.93 1.80 247 184 145 93.0 69.5 57.4 1.85 45.5 36.5 26.0 20.4 16.9 11.5 9.60 8.16 5.34 4.51 T12V100 1.75 284 206 158 96.3 71.6 58.9 1.80 48.2 38.7 27.6 21.7 17.9 12.2 10.2 8.63 5.64 4.76 1.67 306 224 166 98.4 71.9 59.3 1.75 49.4 39.7 28.3 22.2 18.4 12.5 10.4 8.87 5.80 4.91 1.80 270 201 159 102 76.0 62.8 1.85 49.7 39.9 28.4 22.3 18.4 12.6 10.5 8.93 5.84 4.93 T12V110 1.75 310 225 172 105 78.3 64.3 1.80 52.7 42.3 30.2 23.7 19.6 13.3 11.1 9.44 6.16 5.21 1.67 334 245 181 108 78.6 64.7 1.75 54.0 43.4 30.9 24.2 20.1 13.7 11.4 9.70 6.34 5.36 1.80 319 238 188 120 89.8 74.3 1.85 58.8 47.2 33.6 26.4 21.9 14.9 12.4 10.6 6.90 5.84 T12V125 1.75 367 266 204 124 92.6 76.1 1.80 62.4 50.1 35.7 28.0 23.2 15.8 13.1 11.2 7.29 6.16 1.67 396 290 214 127 93.0 76.6 1.75 63.9 51.3 36.5 28.7 23.8 16.2 13.5 11.5 7.50 6.34 1.80 381 284 224 144 107 88.6 1.85 70.2 56.3 40.1 31.5 26.1 17.8 14.8 12.6 8.23 6.96

1.75 438 318 243 149 111 90.8 1.80 74.4 59.7 42.6 33.4 27.7 18.8 15.7 13.3 8.70 7.35 T12V155 1.67 472 346 256 152 111 91.4 1.75 76.3 61.2 43.6 34.2 28.4 19.3 16.1 13.7 8.95 7.57

Page 6: Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance Milli-ohms Female Terminal Type Battery Weight Outline Dimensions Battery Model 10hour

EverExceed AGM Front Access T Range VRLA Discharge Watts Per Cell (WPC) Data @ 20ºC (68ºF)

Actual battery performance data may be±5% of figures shown above

Rugged Battery Construction

The EverExceed front access T Range batteries are constructed using heavy duty flat pasted plates and “U” fold wrapped using a non woven absorbent glass mat (AGM) separator. This rugged construction ensures that the batteries can be used in UBC seismic zone 4 racks where the battery has to withstand the worst possible earthquake conditions and still continue to deliver reliable standby DC power.

12 year Grid plate Monobloc battery Nominal capacity design life 55 - 155Ah

Deep discharge Maintenance free Recyclable Valve regulated recovery lead - acid

Discharge Data WPC @ 20ºC Discharge Data Watts Per Cell @ 20ºC

Battery Model

End VPC Discharge Time In Minutes

End VPC

Discharge Time In Hours

5 10 15 30 45 60 1.5 2 3 4 5 8 10 12 20 24 1.80 232 177 147 96.0 72.8 60.8 1.85 48.3 38.9 28.0 22.1 18.4 12.6 10.6 9.00 5.90 5.00

T12V55 1.75 255 190 160 99.3 75.1 62.3 1.80 50.8 41.0 29.5 23.3 19.4 13.3 11.1 9.48 6.20 5.26 1.67 278 204 168 102 74.4 63.0 1.75 51.8 42.0 30.1 23.7 19.8 13.5 11.3 9.65 6.33 5.36 1.80 337 258 214 139 106 88.4 1.85 70.1 56.6 40.6 32.1 26.7 18.4 15.4 13.1 8.57 7.26

T12V80 1.75 370 276 233 144 109 90.6 1.80 73.8 59.6 42.8 33.9 28.2 19.4 16.1 13.8 9.01 7.64 1.67 404 296 244 148 110 91.5 1.75 75.3 61.1 43.7 34.5 28.7 19.7 16.4 14.0 9.20 7.79 1.80 420 322 267 174 132 110 1.85 87.5 70.6 50.7 40.0 33.3 22.9 19.2 16.3 10.7 9.06

T12V100 1.75 462 344 290 180 136 113 1.80 92.1 74.3 53.4 42.2 35.1 24.1 20.0 17.2 11.2 9.53 1.67 504 370 305 184 137 114 1.75 93.9 76.2 54.5 43.0 35.8 24.6 20.5 17.5 11.5 9.71 1.80 459 351 292 190 145 120 1.85 95.5 77.1 55.4 43.8 36.4 25.0 21.0 17.8 11.7 9.90

T12V110 1.75 505 376 317 197 149 124 1.80 101 81.2 58.4 46.1 38.3 26.4 21.9 18.8 12.3 10.4 1.67 550 404 333 201 150 125 1.75 103 83.3 59.6 47.0 39.2 26.8 22.3 19.1 12.6 10.6 1.80 543 416 346 225 171 143 1.85 113 91.2 65.5 51.8 43.1 29.6 24.8 21.1 13.8 11.7

T12V125 1.75 597 445 375 233 176 146 1.80 119 96.1 69.1 54.6 45.4 31.2 25.9 22.2 14.5 12.3 1.67 651 478 394 238 177 148 1.75 121 98.5 70.5 55.7 46.3 31.8 26.5 22.6 14.8 12.6 1.80 655 496 412 268 204 170 1.85 135 109 78.2 61.8 51.4 35.3 29.6 25.2 16.5 14.0

1.75 712 531 448 278 210 174 1.80 142 115 82.4 65.2 54.2 37.3 30.9 26.5 17.3 14.7 T12V155

1.67 777 571 470 284 211 176 1.75 145 118 84.2 66.4 55.3 37.9 31.6 27.0 17.7 15.0

Page 7: Standard - Power-all Energia Segura, Proteccion Continua · IEC896-2 (A) Internal Resistance Milli-ohms Female Terminal Type Battery Weight Outline Dimensions Battery Model 10hour

Float Voltage & charging

Constant Voltage charging is recommended Temperature compensation:

Recommended float voltage: 2.27VPC @ 20ºC(68ºF) Apply for temperature range of 0ºC / 32ºF to 40ºC / 104ºF. Float Voltage Range: 2.25VPC to 2.30 VPC @ 20ºC(68ºF) Subtract 3 mV / ºC / cell or 1.7 mV / ºF / cell, above 25ºC / 77ºF. Equalize voltage: 2.35VPC for 12 Hours Add 3mV / ºC / cell or 1.7 mV / ºF / cell, below 25ºC / 77ºF.

For charging 2.27 V/cell is recommended. Recharging time in dependence of charging current The charging voltage must be compensated according to the (guide values) for up to 50, 70 and 90% of capacity at 20°C curve for continuously different battery ambient temperature. and with a charging voltage of 2.27 V/cell.