Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings
description
Transcript of Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings
![Page 1: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/1.jpg)
Session 6KY Type 4A End Treatment
See “Shop Drawings” for TypesFLEAT-SP Slide 6 by Road
SystemsSRT-27 Slide 49 by Trinity
![Page 2: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/2.jpg)
Standard Drawing RBR-035 Guardrail End Treatment Type
4A MUST use App. Shop
Drawings
![Page 3: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/3.jpg)
RBR-035 -KYTC Pay Limits for the
Type 4A is 37'-6” even though the FLEAT Shop Drawing says
12’ 6”?
![Page 4: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/4.jpg)
Installation Instructions for Proprietary Guard Rail End
Terminals This Std Draw Note appears on each Proprietary End
Treatment used in KY - “The Manufacturer SHALL furnish two (2) sets of shop plans to the contractor with each installation”
Each Proprietary End Treatment “see shop drawings” Added to Sect 719.03 of 2012 Std Specs: “Proprietary
end treatments SHALL be installed according to the manufacturer’s assembly or installation instructions”
SHOULD NOT LET THE CONTRACTOR BEGIN INSTALLATION BEFORE SUPPLYING YOU WITH THESE SHOP PLANS & INSTALLATION INSTRUCTIONS – Both you and the contractor need these documents to properly do your jobs of installing and inspection propriety guardrail end terminals
![Page 5: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/5.jpg)
How do you know which version of a Proprietary Guardrail End
Treatment KY is Using?
Go to the KYTC Div of Design Home Page http://transportation.ky.gov/Highway-Design On the right click on Standard Drawings Brings up:
Standard Drawings Active Sepia List Approved Shop Drawings - Click
The drawings show the version 350, SP, 27 etc. Good general information on the Shop Drawing
![Page 6: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/6.jpg)
Approved Shop Drawings Type 4A
Click for Alternate 1 or 2
![Page 7: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/7.jpg)
Approved Shop DrawingType 4A Alternate - FLEAT-
SP
![Page 8: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/8.jpg)
Type 4A End TreatmentFLEAT-SP (Std Post) Installation
http://roadsystems.com/fleat.html
![Page 9: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/9.jpg)
FLEAT & SKT-SP Road Systems
http://roadsystems.com/pdf/fleat/SP-Installation-Manual.pdf
SKT-SP & FLEAT-SP
A very easy to follow“Assembly Instructions”
With Drawings and Photos
As I noted in the Type 1 Discussion we will cover both
the Type 1 SKT-SP and the Type 4A FLEAT-SP
Installation together with the Type 4A Discussion
![Page 10: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/10.jpg)
FLEAT FLared Energy Absorbing Terminal
Absorbs Energy by Kinking & Extruding the Rail Thru Impact
Head
![Page 11: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/11.jpg)
The FLEAT Extrudes the Rail Toward Traffic in a Tight Roll
Thru Impact Head and Feeded Chute
![Page 12: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/12.jpg)
Type 4A FLEAT-SP
http://roadsystems.com/fleat.html
FLEAT-SP (FLared Energy Absorbing
Terminal – Standard Post System) is an energy-absorbing flared terminal -NCHRP 350 APPROVED
Flare is straight and the offset is variable between 2'-6" and 4'-0” - KY only uses 4’
No strut, but does have a soil plate at Post 1
![Page 13: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/13.jpg)
FLEAT Variable Offset KY = 48”
2’-6” 4’-0”
Road Systems, Inc.
![Page 14: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/14.jpg)
Type 4A FLEAT-SP http://roadsystems.com/fleat.html
FLEAT-SP Guardrail has SLOTS Toward
The Impact Head Cable Anchor Bracket has Special Bolts
with Widened Shoulders
![Page 15: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/15.jpg)
Type 4A FLEAT-SP 4 Foot Offset
![Page 16: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/16.jpg)
Installation Procedures for FLEAT-SP and SKT-SP
Install standard steel guardrail posts #3 - #6 (on a straight 48” flair Post 7 to Post 1 FLEAT)
Install breakaway steel end posts #1 and #2 Install guardrail. All posts are spaced at 6'-3" Install cable anchor bracket Install the SKT-SP or FLEAT-SP impact head Install cable assembly
![Page 17: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/17.jpg)
Install Post 3-6 Requires Standard Post
at 6’3” Post Spacing
![Page 18: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/18.jpg)
Energy Absorbing End TreatmenttsSTRAIGHT FLARE / NOT CURVED
NO C
URVES
![Page 19: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/19.jpg)
Post 1 and 2 are Hinged to Facilitate Bending of the Post
Upon ImpactPost 1 has a Soil Plate -
Downstream
![Page 20: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/20.jpg)
Post 1 and 2 are Hinged to Facilitate Bending of the Post
Upon ImpactPost 1& Post 2 are NOT the Same
Post 1 and 2 are NOT the same Post 1 and 2 are both two part Post
that Bend or Hinge on Impact Install the bottom of the Post
before connecting the Top portion of each Post
![Page 21: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/21.jpg)
Post 1 and 2 are HingedPost 1 has a Soil Plate -
Downstream
![Page 22: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/22.jpg)
IMPORTANT SKT-SP and FLEAT-SPAssure the 5/8” or 3/4” Hinge Bolts
are at the Proper Locations
![Page 23: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/23.jpg)
IMPORTANT SKT-SP and FLEAT-SPAssure the 5/8” or 3/4” Hinge Bolts
are at the Proper Locations Post 1 – 5/8” x 8 ½” bolt, nut & 2
washers are on UPSTREAM side of the post (toward Impact Head)
Post 2 - ¾” x 8 ½” bolt and nut (no washers) on DOWNSTREAM side of the post (away from Impact Head)
![Page 24: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/24.jpg)
Post 2 is Hinged so it will bend over upon impact, slot allows the post to release from the
guardrail bolt
Traffic
![Page 25: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/25.jpg)
Post 2 -Assure the Guardrail Connection Bolt Slot is Facing Post
#1 – Guardrail Connection Bolt slides out upon Impact
![Page 26: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/26.jpg)
Post 2 is Installed Incorrectly!! Top and Bottom are Installed Backward – Post
Cannot Hinge properly – GR Bolt Cannot Release Properly
Traffic
![Page 27: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/27.jpg)
Post 3-6 require Standard Post With 8” Offset Blocks
Post 1 & 2 no Offset BlocksTherefore Post 1&2 do not line
up with other Post
![Page 28: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/28.jpg)
Install the rail from Post 6-3 with 8” Offset Blocks and Post 1-2 No Offset Blocks Do
NOT Attach Guardrail to Post 1 or 3 (Type 4A FLEAT)
![Page 29: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/29.jpg)
Type 1 “SKT-SP” Guardrail Bolt is Connection to Post 3 - Correct Installation
Post 3
SKT-SP Connect the Guardrail
to Post 3 as shown
![Page 30: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/30.jpg)
Type 4A “FLEAT-SP”NO Guardrail Bolt Connection
to Post 3 - Incorrect Installation
Post 3
FLEAT-SPDo NOT Connect the Guardrail
to Post 3 just Connect the Block Out
![Page 31: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/31.jpg)
FLEAT-SP – Guardrail Correctly “NOT” Bolted to
Post 3 – just Connect Offset Block to Post 3
![Page 32: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/32.jpg)
Guardrail Post 1-3 has 10 slots to Facilitate Bending the Rail as it
Extrudes thru the Impact Head and 8 Bolt Holes
![Page 33: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/33.jpg)
Cable Anchor Bracket – Install Shoulder Bolts Washers, Nuts and
Bracket Bolts Heads on Inside of Rail NOT
Outside
Note: 2 washers on each bolt
![Page 34: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/34.jpg)
Cable Anchor Bracket – Designed to Release During an Impact
Bracket
Bolted to Rail(8 places)
Road Systems, Inc.
Bracket rest on Shoulders of Bolts
![Page 35: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/35.jpg)
Finger tighten Bolts & Washers – align slots on bracket with shoulder of bolts - tap into place with a hammer then
tighten bolts
![Page 36: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/36.jpg)
Note how the Cable Anchor Bracket rest Snugly on the
Shoulders of the Special Bolts
![Page 37: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/37.jpg)
Assure Anchor Bracket is fully seated on Shoulder Portion of the Cable Anchor Bolts - Openings on Cable Anchor Bracket toward
Post 1Bolts Installed Incorrectly – Nuts on Inside
Bolt head placed on Front Side of
Railwithout Washer
Bolts installed backwards with nuts on inside
![Page 38: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/38.jpg)
SKT & FLEAT - Post 1 is HingedArm on Impact Head Helps Bend
Post
![Page 39: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/39.jpg)
The Guardrailis NOT attached
to Post 1.The Impact Head is.
![Page 40: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/40.jpg)
Impact Head Attachment @ Post 1, 5/16” Grade 5 bolts need 2 washers each (1
under nut & 1 under bolt head) and they need tightening
![Page 41: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/41.jpg)
Improper Installation - Extruder Head not Pushed all the way on
![Page 42: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/42.jpg)
SKT-SP Cable feed inside/thru the Feeder Chute FLEAT-SP cable does NOT
![Page 43: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/43.jpg)
8”x8” Bearing Plate oriented Properly with Washer (5” up) - need restraining tie to keep Bearing Plate from Twisting
![Page 44: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/44.jpg)
Orientation of Bearing Plate Which Bearing Plate is almost Correct? Road Systems recommends a Restraining
Tie
![Page 45: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/45.jpg)
Tighten AnchorCable – Using Vice Grips, on Shank not on the Cable, to
prevent twisting of the Cable
![Page 46: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/46.jpg)
FLEAT-SP Checklist Rail height is 27 ¾” Minimum No Curved Rail SKT-SP 50’ FLEAT-SP
37’ 6” Guardrail is NOT attached at Post 1 & 3 End Rail Panel has Special Slots Hinge Bolt @ Post 2 is Downstream Hinge Bolt @ Post 1 is Upstream Bolt Slots in Post 2 Face Upstream
![Page 47: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/47.jpg)
FLEAT-SP ChecklistContinued
Stubs of Post 1&2 do not stick up 4” Straight 4’ Flare Bolts Holding Impact Head are Properly
Installed and Secure (2 washers each) 8”x8” bearing Plate Oriented with 5” up Cable Anchor Brackets Properly Installed
Such that Bracket is Fully Seated on the Bolt Shoulders
Cable Taught
![Page 48: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/48.jpg)
Road Systems Assembly Instructions for
SKT-SP and FLEAT-SP This is a very useful and well done
document http://roadsystems.com/pdf/fleat/S
P-Installation-Manual.pdf
![Page 49: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/49.jpg)
Type 4A AlternateSRT-27
![Page 50: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/50.jpg)
Type 4A – SRT-27 Trinity Highway products
http://www.highwayguardrail.com/products/cb.html
![Page 51: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/51.jpg)
One of the first KY Field Installations of the SRT-27
Length of Need???
![Page 52: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/52.jpg)
Type 4AInstallation Manual
For the SRT-27 this is on line at: http://www.highwayguardrail.com/produc
ts/et-srt350.html which has a link to the SRT-27 Installation Instructions & Shop Drawings in the right hand column near the bottom
http://www.highwayguardrail.com/products/pdfs/SRT-27%20%20SRT-31%20Flip%20Manual.pdf
Shop Drawing on KYTC Design Web Page
![Page 53: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/53.jpg)
SRT-27 Installation Instructions
![Page 54: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/54.jpg)
SRT-27Slotted Rail Terminal – 27
Inch
Need PHOTOS OF Crashed SRT-27
![Page 55: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/55.jpg)
Shop Drawing SRT-27
![Page 56: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/56.jpg)
SRT-27Title Block and Parts List
SRT-27 ERECTION DETAILS( 3 PANELS and
CR and SYT POST)
![Page 57: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/57.jpg)
SRT-27: Slotted Rail Terminal – 27 Inchhttp://www.highwayguardrail.com/products/et-srt350.html
Gating Flared End Terminal Straight Flare Pay Limits 37’ 6” The SRT-27 is not an Energy
Absorbing End Treatment
![Page 58: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/58.jpg)
Slide of schematic from installations instructions
SRT-27
![Page 59: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/59.jpg)
IInstallation Procedures for
Type 4A – SRT-27 Post 1 – CR (Controlled Release)Post Strut Between Post 1&2 Post 2-6 SYTP Post (Steel Yielding Terminal
Post) Post 3-6 have 8” Offset Blocks Guardrail is not connected at Post 2, 3, 4 or 5 Standard Guardrail begins @ Post 7 37’ 6” long on a straight flare
![Page 60: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/60.jpg)
SRT-27 Post Installation Begin @ Post 9 to establish the
Guardrail Tangent Line @ T7 – extend to T1
Measure from T1 an offset of 4’0” perpendicular to roadway – Estb. backside of guardrail for Post 1
Measure offsets of Post 7-8 Estb. Straight line between Point 1 &
Point 7 (represents back side of rail)
![Page 61: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/61.jpg)
SRT-27 Post InstallationBegin @ Post 9 to establish the Guardrail
Tangent Line @ T7 – extend to T1
![Page 62: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/62.jpg)
SRT-27 Post Installation Continued
Establish Points 2-6 @ 6’3” intervals Installing the SYT (Steel Yielding
Terminal) Post 2-6 The Center of the Yielding Holes in
the Post is Approx. @ Finished Grade Careful – do not mix SYT and SP
(Standard Post) in the Type 4A Guardrail End Treatment – except for 4 holes @ ground line – very similar
![Page 63: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/63.jpg)
Drive SYT Post at Post 2-6. Careful SYT Post and SP (Std
Post) look very similar – DO NOT INTERMIX
SYT Post have4 holes nearGround Line
DO NOT INTERMIX
SYT Post and SP Post
![Page 64: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/64.jpg)
Center of the Yielding Holes in the Post is Approx. @
Finished Grade
![Page 65: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/65.jpg)
SRT - 27 Post 1 CR (Controlled Release) Post
Installation CR Bottom Post Installation
Orient lower portion of CR Post so the ¾” Strut Attachment Hole is closer to the nose of the system
Place where the Strut Hole is Approx. @ Finished Grade
See Manufactures Instructions if Rock is Encountered
![Page 66: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/66.jpg)
Orient lower portion of CR Post so the ¾” Strut Attachment Hole is closer to the nose of the system
![Page 67: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/67.jpg)
SRT-27 Post 1 CR Post Installation
CR Top Post Installation Align the ears of the top and bottom –
top plate goes in front of the bottom (shop drawing)
Insert a 5/16” x 1 ¾” Hex head Bolt in each of the 3/8” holes in bottom and top post plates – use a 5/16” washer under the hex nut
Tighten the nut (no torque requirements)
![Page 68: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/68.jpg)
Post 1 CR Top Portion Installation
Align the ears of the top and bottom
Front View Back View
Slight Angle
![Page 69: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/69.jpg)
Insert a 5/16” x 1 ¾” Hex head Bolt in each of the 3/8” holes in bottom and top post plates – use a 5/16” washer under the
hex nut
5/16” Hex Bolt Washer & Nut each side
![Page 70: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/70.jpg)
Insert a 5/16” x 1 ¾” Hex head Bolt in each of the 3/8” holes in bottom and top post
plates – use a 5/16” washer under the hex nut
5/16” Hex Bolt Washer & Nut
each side
![Page 71: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/71.jpg)
Post 1 Incorrect Align the ears of the top and bottom – top plate goes in front of
the bottom (shop drawing). Cable Anchor Bracket flush
Bottom Post 1 driven backwards. Bottom Post 1 only has 1 hole and it is to be toward front.
Cable Anchor Bracket NOT Flush & Gap Between Top Bottom Ears & does not Align properly.
![Page 72: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/72.jpg)
SRT-27 – Installing the Strut between Post 1 & 2
Part of the Angle Strut is below grade – installer must provide a shallow valley
Place the Angle Strut outside the Post Ear of Post 1 and backside of the SYT Post @ Post 2
Place a 5/8” x 1 ¾” High Strength Hex Bolt thru ¾” hole in Post Plate and thru Slot in Strut @ Post 1 – place 5/8” Washer Under Bolt Head and Hex Nut
![Page 73: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/73.jpg)
SRT-27 – Installing the Strut at Post 1
Strut in Shallow Valley
![Page 74: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/74.jpg)
Place a 5/8” x 1 ¾” High Strength Hex Bolt thru ¾” hole in Post Plate
and thru Slot in Strut @ Post 1 – place 5/8” Washer Under Bolt Head and
Hex NutWashers are
ImportantIncorrect
Loose Fit Without WasherCorrect
Tight Fit With Washer
![Page 75: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/75.jpg)
SRT-27 – Installing the Strut Post 2
Post 2 Insert 7/16” x 1 ¾” High Strength Hex Bolt with 7/16” washer thru each of the ½”ground holes of the SYT Post and thru the slots of the Strut – place 7/16 Lock Washer and Nut on end of bolt
Tighten all Bolts – no Torque Requirements
![Page 76: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/76.jpg)
SRT-27 – Installing the StrutPost 2
Washers are Important
IncorrectLoose Fit Without Washer
CorrectTight Fit With Washer
![Page 77: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/77.jpg)
SRT-27 Installing Rail Panels
The Guardrail from Post 7 to Post 5 does NOT have Slots
Layout the Guardrail so Slot Guard Attachment Holes @ the ends of the Slots (away from Post 1)
Position Guardrail with Long Slots between Post 1&2 Post 2&3
Position Guardrail with Short Slots between Post 3&4 and Post 4&5
Splice and Post Bolt the 12’ 6”rail panel at Post 7 to the run of rail
![Page 78: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/78.jpg)
SRT-27 Installing Rail Panels
ContinuedShort Slots Long SlotsNo Slots
Slot Guards Away From Post 1Connect to
Standard Rail @ Post 7
![Page 79: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/79.jpg)
Long Slots Between Post 2 & 3 and 1 & 2
Long Slots BetweenPost 2 & 3
Long Slots BetweenPost 1 & 2
![Page 80: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/80.jpg)
Short Slots Between Post 4 & 5 and 3 & 4
Short Slots BetweenPost 4 & 5
Short Slots BetweenPost 3 & 4
![Page 81: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/81.jpg)
No Slots Between Post 6 & 7 and 5 & 6
No Slots BetweenPost 6 & 7
No Slots BetweenPost 5 & 6
![Page 82: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/82.jpg)
SRT-27 Installing Rail Panels
Continued
Insert and tighten 5/8”x10” Post Bolt thru 8” Offset Blocks and attach 5/8” Hex Head HGR Nut at Post 5, 4, and 3 (rail Panels are NOT attached to Post 2, 3, 4, & 5)
Post 2 Insert and tighten 5/8”x2” HGR Post Bolts thru 2 holes in Flange Protector (6” Backup Plate) and the Post Shelf Angle with a 5/8’ HGR Hex Nuts
![Page 83: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/83.jpg)
No BOLT to Rail Connection
@ Post 2, 3, 4, & 5
Post 2 Post 3
![Page 84: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/84.jpg)
No BOLT to Rail Connection
@ Post 2, 3, 4, & 5
Post 4 Post 5
![Page 85: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/85.jpg)
Rail is Bolted @ Post 6
Post 6
![Page 86: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/86.jpg)
Flange Protector & Shelf Angle Post 2 two 5/8” HGR Bolts &
Nuts
![Page 87: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/87.jpg)
Flange Protector & Shelf Angle Post 2
![Page 88: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/88.jpg)
SRT-27 Installing Rail Panels
Continued Splice the Rail Panel to the second Rail
Panel at Post 5 with Splice Bolts and Nuts
Insert 5/8”x10” HGR Post Bolt thru the Rail Panel and Offset Block at Post 6 and secure with Hex Nut and Tighten
Splice the Rail Panel to the first Rail Panel at Post 3 with Splice Bolts and Nuts
![Page 89: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/89.jpg)
Rail Panel does get Bolted to Post @ Post
6
Post 6
![Page 90: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/90.jpg)
SRT-27 Installing Rail Panels
Continued Insert 5/8”x2” HGR Post Bolt thru the
Rail Panel at Post 1 and secure with Hex Nut and Tighten – Trinity has informed me that the bolt at Post 1 should be placed on the downstream side of the post (toward Post 2) – this is in response to reports of loose cables.
Your Rail Panels are now attached
![Page 91: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/91.jpg)
SRT-27 Installing Slot Guards on Downstream
End of Slots Place 4 Slot Guards against backside of
the Guardrail Panels with Deflector Angle Gap Opening toward the Elongated Slots and connect with six 5/8”x1 1/4” Splice Bolts and Nuts – bolts inserted from front of rail
Traffic
![Page 92: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/92.jpg)
SRT-27 Installing Slot Guards
TRAFFIC
![Page 93: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/93.jpg)
2nd Rail Panel Installed Backwards
Thus Slot Guards on Incorrect End of Slots
Traffic
![Page 94: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/94.jpg)
SRT-27 Installing Cable Anchor Assembly
Place 5/8” Washer on each of the eight 5/8” Hex Head Bolts
Insert the Bolts thru the Traffic Side of the Rail Panel and the Cable Anchor Bracket (on the backside of the Rail Panel) & Secure with Hex HGR Nuts
![Page 95: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/95.jpg)
Front and Back of Cable Anchor Assembly Bolts & Washers (front) and Nuts
(Back)Back of Rail
TrafficFront of Rail
Traffic
![Page 96: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/96.jpg)
SRT-27 Installing Cable Anchor Assembly
Continued Slide one end of Cable into Cable Anchor
Bracket Place 1” washer and Hex Nut on End of the
Cable extending thru the Cable Anchor Bracket
![Page 97: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/97.jpg)
SRT-27 Installing Cable Anchor Assembly @ Post 1
Slide the other end of Cable thru the Hole Between the Top and Bottom CR Post 1
At Post 1 Place the Cable Anchor Bracket on the Cable
Place the Short Bent Leg of the Cable Anchor Bracket over the Top Edge of the Post Plate
Secure with a 1” Washer and Hex Nut
![Page 98: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/98.jpg)
SRT-27 Installing Cable Anchor Assembly @ Post 1
![Page 99: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/99.jpg)
View of Cable Anchor Assembly in Front of Post
1
![Page 100: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/100.jpg)
View of Cable Anchor Assembly from Top Post 1
![Page 101: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/101.jpg)
View of Cable Anchor Assembly From Behind
Post 1
![Page 102: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/102.jpg)
SRT-27 Installing Cable Anchor Assembly
Continued Restrain the cable with a Vice Grip
at the End being Tightened to avoid Twisting the Cable
Tighten until Taught Cable Anchor Assembly is now
complete
![Page 103: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/103.jpg)
SRT-27 Installing End Section
Connect the End Section to the End of the Guardrail with four 5/8”x1 ¼” HGR Splice Bolts and Hex HGR Nuts
Install High Intensity Reflective Sheeting
![Page 104: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/104.jpg)
SRT-27 Installing End Section
![Page 105: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/105.jpg)
SRT-27 Installation Checklist
Rail Height 27 ¾” Minimum Site grading such that Ears on bottom of
CR Post 1 do not exceed 4” above ground Anchor Cable Taught Guardrail is NOT attached @ Post 2, 3, 4
& 5 Slot Guards in place and Deflector Angle
Gap Opening oriented toward Elongated Slots
![Page 106: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/106.jpg)
SRT-27 Installation ChecklistContinued
Guardrail panels Oriented correctly and Lapped in direction of Traffic
Backfill around Post if necessary and properly compacted
SYT Post 2-6 Center of Yielding Holes are approx. at the Finished Grade
![Page 107: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/107.jpg)
Completed Trinity SRT-27 Assembly
@ Roadway Products – Mid-ParkClarkson KY
![Page 108: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/108.jpg)
SRT-27 and FLEAT-SP Installation manuals
SRT-27 SKT-SP & FLEAT-SP
![Page 109: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/109.jpg)
Manufactures Installation Info
FLEAT-SP Road Systems http://roadsystems.com/fleat.html http://roadsystems.com/pdf/fleat/SP-Installation-Manual.pdf
SRT-27 Trinity Highway Products http://www.highwayguardrail.com/products/et-srt350.html which has a link to the SRT-27 Installation Instructions lower right column
Note: SRT-27 Shop Drawing only available on KYTC Design web page - Standard Drawings
![Page 110: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/110.jpg)
1. Q & A TimePost 2 FLEAT OK??
Post 2 Installed Backwards
Cannot hingeor releasefrom rail
![Page 111: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/111.jpg)
2. Q & A TimeWhat is Incorrect here??
Bearing Plate Rotated5” to be up
Cable extremely loose
![Page 112: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/112.jpg)
3. Q & A Time FLEAT-SP Third Post
Guardrail @Post 3 of FLEATIs NOT Attached
Offset Block is Attached
![Page 113: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/113.jpg)
4. Q & A TimeFLEAT-SP Cable Anchor Bracket
Frontof Rail
Back of Rail
Bolts Installed Backwards
![Page 114: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/114.jpg)
5. Q & A TimePost 1 FLEAT-SP
Anything Missing??
Washers Missing Under Nut & Bolt Head on Top Bolts
![Page 115: Standard Drawing RBR-035 Guardrail End Treatment Type 4A MUST use App. Shop Drawings](https://reader035.fdocuments.us/reader035/viewer/2022062305/56815a83550346895dc7f169/html5/thumbnails/115.jpg)
6. Q & A TimeSKT-27
The SKT-27 - is Unique because the Guardrail is NOT attached @ Post???
Guardrail is NOT attached @ Post 2, 3, 4 & 5