Standard Capacity Gas Turbine Meter Brochure Overview Definitions and Turbine Meter Parameters Accurate Measurement Explained Product Features Specifications Pulse Characteristics Spindown Times Meter Markings Catalog Numbers Sizing Requirements Four Ways of Meter Proving Overanging and Maintenance Oiling Instructions Flow Sizing Charts 4" 6" 8" 12" Dimensional Information Inches Millimeters Parts List and Drawing Preamplifiers and Transmitters Metertubes Length of Tubes Alignment of Tubes Recommended Piping Layouts Strainers Flow Computing Systems Gas Flow Instrumentation

Transcript of Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine...

Page 1: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Standard Capacity Gas Turbine Meter Brochure

OverviewDefinitions and Turbine Meter ParametersAccurate Measurement ExplainedProduct FeaturesSpecificationsPulse CharacteristicsSpindown TimesMeter MarkingsCatalog NumbersSizing RequirementsFour Ways of Meter ProvingOveranging and MaintenanceOiling Instructions

Flow Sizing Charts  4"  6"  8"  12"

Dimensional Information        Inches        Millimeters  

Parts List and DrawingPreamplifiers and Transmitters

Metertubes        Length of Tubes        Alignment of Tubes        Recommended Piping Layouts        Strainers

Flow Computing SystemsGas Flow Instrumentation

Page 2: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Product/System OverviewGAS TURBINE METERS4" THROUGH 12"CATALOG 2000

GENERAL INFORMATION

ForewordDaniel Industries, Inc. is a recognized leader in the field of flow measurement. The Flow Products Division hasas its goal the development and manufacture of the most accurate and reliable flow measurement equipment inthe industry. From entire packaged meter stations to specific components, the Daniel expertise is there.

Daniel's Gas Turbine Meter is an example of this expertise and leadership position in flow measurement. Themeter is unique in its design. It has fewer moving parts because of its patented electronic design. Incombination with Daniel's totalizing and computing equipment, the gas turbine meter becomes the heart of gasmeasurement systems for virtually any situation.

DANIEL GAS TURBINE METER SYSTEM

GAS TURBINE METER

Wide rangeability●

High accuracy reliability●

Two pulse outputs●

Lexan rotor, heavy duty bearings●

External lubrication system●

MRT 94

Continuous display flow rate and totalization●

Pulse out●

4-20 MA signal out (loop power)●

Battery power 2-year life (Lithium)●

Explosion proof housing●

10-Point linearization●

Page 3: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Gas Turbine Meter shown with Model MRT 94 Flow Totalizer

 

Page 4: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Turbine Meter ParametersAccuracy is a measure of how close to true or actual flow the instrument indication may be. It is generallyexpressed as a percent of true volume for a specific flow range. This is a "worst case" rating. Accuracy at aparticular flow rate may be an order of magnitude better than "rated flow range accuracy."

Resolution is a measure of the smallest increment of total flow that can be individually recognized. Highresolution is generally required only on meters handling the sale of products which must be periodically proved,or on meters for control purposes. Electro-magnetic turbine meters have an inherently high resolution.

Repeatability is a meter's ability to indicate the same reading each time the same flow conditions exist.Turbine meters exhibit excellent repeatability and, for many control applications, this parameter is moreimportant than accuracy or resolution.

Range is the ratio of maximum flow to minimum flow over which the specified accuracy will be maintained.

 

Page 5: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Accurate Measurement ExplainedAs the gas flow enters the meter inlet, it is guided through a flow area created by the inside diameter of themeter and the outside diameter of the flow deflector. The flow deflector or nose cone is used to increase thevelocity of the gas to prepare its entry to the meter rotor. The increase in velocity provides ample rotor drivingforce.

After the flowing gas has been accelerated, it flows through the meter rotor. The rotor is designed with aspecific number of blades positioned at a precise angle to the flow stream. The gas impinges on the rotorblades causing the rotor to rotate. The angular velocity of the rotor is directly proportional to the gas velocityand consequently to the volumetric flow rate.

Hence, by accurately measuring the rotor rotation, the volumetric flow can be determined.

The Daniel Gas Turbine Meter is furnished with two magnetic pick ups which sense the rotation of the rotorthrough accurately positioned magnets in the rotor hub. As the magnet passes the coil it produces a voltagepulse which represents a discrete unit of volume. The turbine meter output is rated in pulses per unit volume.

Daniel offers two independent, isolated pick ups which can be used with the Daniel local totalizer and/or flowinstrumentation capable of accepting inputs of pressure, temperature, and density transducers for calculationsof corrected flow or mass.

Page 6: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

...........................

Page 7: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Product FeaturesGAS TURBINE METERS4" , 6", 8" AND 12"

High resolution, repeatability and rangeability●

Pressure ratings through ANSI Class 900●

Only six major parts, only two moving parts●

 

 

 

 

 

Use with Daniel or other electronic rate-indicator/totalizer or computer

...........................

Page 8: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

SpecificationsTEMPERATURE LIMITSMeter:Operational 0 to 220ºFStorage -50 to 200ºF

Preamplifier:Operational 0 to 140ºF (above 150ºF, mount electronics remotely)Storage -50º to 140ºF

LINEARITYOver stated range ±1%; limited range ±0.5%(Repeatability at any point in stated range ±0.1%)

OVERRANGE25% over maximum flow for short periods only

MATERIALS

Part Material

Meter Body 4", 6", 8" carbon steel or aluminum; 12" carbon steel

Rotor AluminumBall Bearings Stainless Steel

Pickup Coil 1500-1700 ohms inductance, in S.S. housing

STANDARDModel 1816 Preamplifier, direct-feed oiler, dual coils

OPTIONSExternal oil tank, Model 2415B Preamplifier for Intrinsically Safe applications

...........................

Page 9: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Pulse CharacteristicsPULSE CHARACTERISTICS

METER SIZE PULSES/ACTUALCUBIC FEET

PULSES/ACTUALCUBIC METER

FREQUENCY ATMAX FLOW (Hz)

4" 115 4060 575

6" 32 1130 320

8" 20 706 333

12" 6 212 250

...........................

Page 10: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Typical Spin Down TimeLine Size Time in Seconds

4" (100 mm) 70

6" (150 mm) 100

8" (200 mm) 130

12" (300 mm) 150

...........................

Page 11: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Meter Markings

METER MARKINGS

Each meter has FLOW DIRECTION & FLANGE RATINGS.Meter should be installed in accordance with these markings:Upstream Inlet flange is stamped: INDownstream Inlet flange is stamped: OUT

 

Page 12: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Meter Numbering System/Ordering &Shipping InfoGENERAL INFORMATIONDANIEL GAS TURBINE METER NUMBER SYSTEM

4" -- 20 - 1 - 1Code Explanation/Example

4" Meter line size in inches

20 Gas Turbine Meter

1 0 Flat Face (125# Meter Only)1 Raised Face Flanges, both ends4 Ring Type Joint Flanges, both ends

1 Pressure Rating ANSI0 Class 125 ANSI1 Class 150 ANSI3 Class 300 ANSI5 Class 600 ANSI6 Class 900 ANSI

WHEN ORDERING, PLEASE SPECIFY:

Type of gas (dry, wet, sour, etc.)1. Maximum line pressure2. Maximum flow rate3. Minimum flow rate4. Quantity5. Type readout required6. Model number7.

METER PACKING AND SHIPPINGEach Daniel Gas Turbine Meter is individually crated to avoid damage during shipment. Meter flanges and boreare protected by covers.

 

Page 13: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Meter Sizing and ProgrammingThe following informatin is required for proper sizing and programming of the Daniel Gas Turbine Meter:

(1) Maximum Flow Rate SCFH or SCFD NCMH or NCMD

(2) Minimum Flow Rate SCFH or SCFD NCMH or NCMD

(3) Maximum Flowing Pressure PSIG kg/cm^2

(4) Minimum Flowing Pressure PSIG kg/cm^2

(5) Specific Gravity SG SG

(6) Flowing Temperature ºF ºC

(7) Base Pressure PSIA kg/cm^2

(8) Base Temperature ºF ºC

(9) Normal Line Pressure PSIG kg/cm^2

NOTE: (1) AND (2) should be given for a specific flowing pressure and temperature.

CAUTION: When sizing Daniel Gas Turbine Meters using maximum flow rate in SCFD, it is necessary to verifythat the instantaneous flow rate does not exceed the hourly rates stated in the Performance Data tables.

 

Page 14: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Four Ways of Meter ProvingSPIN TESTA spin test of the gas turbine meter rotor does not represent absolute proof over the entire range of the meter, but onlyan indication of its accuracy in the lower range. A spin test is conducted and recorded on the gas turbine meterspecification sheet by Daniel prior to shipment, but another test is advised before installation. Be sure to record the spintime of this test for future reference. Conduct the spin test in a relatively draft-free environment or by blocking off back ofinner housing.

PLOT OF PERCENT FLOW RATE vs. PULSES/ACTUAL CUBIC FEETAir Calibration ofDaniel Gas Turbine MeterSerial No.: 74-G-100Model No.: 2000-0Size: 4"

Curve No.: 74-111Customer: Natural Gas Co.

Customer P.O.: 123-456Daniel S.O.: 99999

Date: 1-15-74

 

 

 

 

 

 

 

 

 

These spin down times and their respective calibration curves represent an example of a typical 4" gas turbine meterand indicate the loss due to friction in bearings. If friction is indicated by unsuitable spin down time, the bearings shouldbe replaced.

CRITICAL FLOW PROVERS--ORIFICE/VENTURIA critical flow prover is a constriction type flow meter in which the phenomenon of critical flow occurs as the gas velocityin the throat of the meter is accelerated to equal the velocity of sound in the pipe at operating conditions. Critical flowprovers are of two types--the critical flow orifice prover and the critical flow venturi prover.

The critical flow prover test method has the advantage of the meter being tested under the same conditions andconfiguration that it normally operates.

Page 15: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

The critical flow orifice prover is used to test gas turbine meters at operating pressures of 15 psig or more. Flow ispassed through the meter and the orifice, then discharged into the atmosphere.

The critical flow venturi prover also is used to test gas turbine meters at 15 psig or more. The venturi is installed as an"in-line" device so that gas flows through the meter, through the venturi, then back into the pipeline. There is no loss ofgas due to venting, no high noise levels, and no hazardous conditions. The venturi outlet section is designed to recover90-95% of the critical pressure loss.

TRANSFER PROVERTransfer proving consists of meter calibration by means of a transfer or master meter. In transfer proving, the mastermeter and the test meter are piped in series. A selected volume of gas is simultaneously passed through both meters,and their registration is observed. The observations (registrations) are then corrected for any temperature and pressuredifferences between the two meters. A percentage error is determined for any flowing conditions by installing the mastermeter in the pipeline with the test meter or at atmospheric conditions by installing the test meter in series with the mastermeter and utilizing a portable blower to provide the volume through the two meters.

Two devices which can be used as master meters in transfer proving are the gas turbine meter and the orifice meter. Ofthe two devices, the master gas turbine meter provides a system that is simple, accurate, repeatable, fast, and requiresless additional instrumentation.

 

Page 16: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Overrange and Maintenance

OVERRANGEThe gas turbine meter is a velocity (rate) sensing device. Extreme gas velocity encountered duringpressurizing, venting, and purging of meter tube or system can cause severe damage due to sudden andsevere overranging. All such operations should be conducted under controlled conditions in order to maintainmeter accuracy and trouble free service.

NOTE: The Daniel Gas Turbine Meter is designed to accept gradual 25% overranging surges during normaloperation. It can withstand a gradual 100% overranging, but internals will suffer accelerated deterioration.

MAINTENANCEA maintenance manual is supplied with each Daniel Gas Turbine Meter.

APPLICATIONSDaniel Gas Turbine Meters are applicable to wide flow ranges, fluctuating flows, and to extend the range ofexisting meter stations. This versatility and its accuracy make the Daniel Gas Turbine Meter a popularmeasurement device for:

Peak Shaving●

Fuel Gas for Compressors of Boilers●

Town Border Stations●

Gas Production Operations●

Gas Transmission Lines●

 

Page 17: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Oiling InstructionsALL METERS SHOULD BE LUBRICATED PRIOR TO STARTUP

METER BEARING LUBRICATION

Close valve & remove cap slowly.1. Fill reservoir with recommended oil.2. Replace cap & tighten securely.3. Slowly open valve to allow drainage.4. Close valve.5.

RECOMMENDED OIL VISCOSITY

MeterSize

Viscosity(Centistokes)

4" 20 cs.

6" 50 cs.

8" 100 cs.

12" 50 cs.

Daniel recommends use of Dow Corning silicon 200 fluids in all gas turbine meters. For name ofdistributor, consult factory.

 

Page 18: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

4" (100mm) Gas Turbine MeterPRESSURE/FLOW CHARACTERISTICS, 4" GAS TURBINE METER

ALL PRESSURES IN PSIG, FLOW RATES IN SCFHAll tables based on standard conditions: 14.73 psia and 60ºF for 0.6 SG gas; supercompressibility not included.

Pressure Maximum Minimum Turndown Approx. MaximumPressure Drop

Psig Bars SCFH Nm^3/hr SCFH Nm^3/hr Ratio IWC millibars

0.00 1.02 18,000 510 1,200 34.0 15:1 1.2 2.9

0.25 1.03 18,305 518 1,210 34.3 15:1 1.2 3.0

1 1.08 19,222 544 1,240 34.1 16:1 1.3 3.1

10 1.71 30,220 856 1,555 44.0 19:1 2.0 4.9

25 2.74 48,550 1,375 1,971 55.8 25:1 3.2 7.9

50 4.46 79,100 2,240 2,515 71.2 31:1 5.2 12.9

75 6.19 109,650 3,105 2,962 83.9 37:1 7.2 17.9

100 7.91 140,200 3,970 3,349 94.8 42:1 9.2 22.8

125 9.64 170,749 4,835 3,696 104.7 46:1 11.2 27.8

200 14.81 262,399 7,430 4,582 129.7 57:1 17.2 42.7

300 21.71 384,599 10,891 5,547 157.1 69:1 25.1 62.6

400 28.60 506,798 14,351 6,367 180.3 80:1 33.1 82.5

500 35.50 628,998 17,811 7,093 200.9 89:1 41.1 102.4

600 42.40 751,198 21,272 7,752 219.5 97:1 49.1 122.3

700 49.29 873,397 24,732 8,359 236.7 104:1 57.1 142.2

800 56.19 995,597 28,192 8,924 252.7 112:1 65.1 162.1

900 63.08 1,117,796 31,652 9,456 267.8 118:1 73.1 182.0

1,000 69.98 1,239,996 35,113 9,960 282.0 125:1 81.1 201.9

1,100 76.88 1,362,196 38,573 10,439 295.6 130:1 89.0 221.8

1,200 83.77 1,484,395 42,033 10,897 308.6 136:1 97.0 241.7

1,300 90.67 1,606,595 45,494 11,337 321.0 142:1 105.0 261.6

1,400 97.57 1,728,794 48,954 11,760 333.0 147:1 113.0 281.5

The above table is based on standard conditions of 14.73 Psia and 60ºF for 0.60 specific gravity gas.Supercompressibility not included.

Page 19: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

6" (150mm) Gas Turbine MeterPRESSURE/FLOW CHARACTERISTICS, 6" GAS TURBINE METER

ALL PRESSURES IN PSIG, FLOW RATES IN SCFHAll tables based on standard conditions: 14.73 psia and 60ºF for 0.6 SG gas; supercompressibility not included.

Pressure Maximum Minimum Turndown Approx. MaximumPressure Drop

Psig Bars SCFH Nm^3/hr SCFH Nm^3/hr Ratio IWC millibars

0.00 1.02 36,000 1,019 2,291 64.9 16:1 1.5 3.7

0.25 1.03 36,611 1,037 2,310 65.4 16:1 1.5 3.7

1 1.08 38,444 1,089 2,367 67.0 16:1 1.6 3.9

10 1.71 60,440 1,711 2,968 84.0 20:1 2.5 6.1

25 2.74 97,100 2,750 3,762 106.5 26:1 4.0 9.9

50 4.46 158,200 4,480 4,802 136.0 33:1 6.5 16.1

75 6.19 219,299 6,210 5,654 160.1 39:1 8.9 22.3

100 7.91 280,399 7,940 6,393 181.0 44:1 11.4 28.5

125 9.64 341,499 9,670 7,055 199.8 48:1 13.9 34.7

200 14.81 524,798 14,861 8,746 247.7 60:1 21.4 53.3

300 21.71 769,198 21,781 10,589 299.8 73:1 31.4 78.1

400 28.60 1,013,597 28,702 12,155 344.2 83:1 41.3 103.0

500 35.50 1,257,996 35,622 13,542 383.5 93:1 51.3 127.8

600 42.40 1,502,395 42,543 14,799 419.1 102:1 61.3 152.6

700 49.29 1,746,794 49,464 15,947 451.9 109:1 71.2 177.4

800 56.19 1,991,193 56,384 17,037 482.4 117:1 81.2 202.3

900 63.08 2,235,593 63,305 18,052 511.2 124:1 91.2 227.1

1,000 69.98 2,479,992 70,226 19,013 538.4 130:1 101.1 251.9

1,100 76.88 2,724,391 77,146 19,928 564.3 137:1 111.1 276.7

1,200 83.77 2,968,790 84,067 20,803 589.1 143:1 121.1 301.6

1,300 90.67 3,213,189 90,987 21,642 612.8 148:1 131.0 326.4

1,400 97.57 3,457,589 97,908 22,450 635.7 154:1 141.0 351.2

The above table is based on standard conditions of 14.73 Psia and 60ºF for 0.60 specific gravity gas.Supercompressibility not included.

 

Page 20: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

8" (200mm) Gas Turbine MeterPRESSURE/FLOW CHARACTERISTICS, 8" GAS TURBINE METER

ALL PRESSURES IN PSIG, FLOW RATES IN SCFHAll tables based on standard conditions: 14.73 psia and 60ºF for 0.6 SG gas; supercompressibility not included.

Pressure Maximum Minimum Turndown Approx. MaximumPressure Drop

Psig Bars SCFH Nm^3/hr SCFH Nm^3/hr Ratio IWC millibars

0.00 1.02 60,000 1,699 3,000 84.9 20:1 1.9 4.6

0.25 1.03 61,018 1,728 3,025 85.7 20:1 1.9 4.7

1 1.08 64,073 1,814 3,100 87.8 21:1 2.0 4.9

10 1.71 100,733 2,852 3,887 110.1 26:1 3.1 7.8

25 2.74 161,833 4,583 4,927 139.5 33:1 5.0 12.5

50 4.46 263,666 7,466 6,289 178.1 42:1 8.1 20.3

75 6.19 365, 499 10,350 7,404 209.7 49:1 11.3 28.1

100 7.91 467,332 13,233 8,372 237.1 56:1 14.4 36.0

125 9.64 569,165 16,117 9,240 261.6 62:1 17.6 43.8

200 14.81 874,664 24,768 11,454 324.3 76:1 27.0 67.3

300 21.71 1,281,996 36,302 13,867 392.7 92:1 39.6 98.6

400 28.60 1,689,328 47,836 15,918 450.8 106:1 52.2 130.0

500 35.50 2,096,660 59,371 17,734 502.2 118:1 64.8 161.3

600 42.40 2,503,992 70,905 19.380 548.8 129:1 77.3 192.7

700 49.29 2,911,324 82,440 20,897 591.7 139:1 89.9 224.0

800 56.19 3,318,656 93,974 22,311 631.8 149:1 102.5 255.3

900 63.08 3,725,988 105,508 23,641 669.4 158:1 115.1 286.7

1,000 69.98 4,133,320 117,043 24,899 705.1 166:1 127.7 318.0

1,100 76.88 4,540,652 128,577 26,097 739.0 174:1 140.3 349.4

1,200 83.77 4,947,984 140,111 27,243 771.4 182:1 152.8 380.7

1,300 90.67 5,355,316 151,646 28,342 802.6 189:1 165.4 412.0

1,400 97.57 5,762,648 163,180 29,400 832.5 196:1 178.0 443.4

The above table is based on standard conditions of 14.73 Psia and 60ºF for 0.60 specific gravity gas.Supercompressibility not included.

 

Page 21: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

12" (300mm) Gas Turbine MeterPRESSURE/FLOW CHARACTERISTICS, 12" GAS TURBINE METER

ALL PRESSURES IN PSIG, FLOW RATES IN SCFHAll tables based on standard conditions: 14.73 psia and 60ºF for 0.6 SG gas; supercompressibility not included.

Pressure Maximum Minimum Turndown Approx. MaximumPressure Drop

Psig Bars SCFH Nm^3/hr SCFH Nm^3/hr Ratio IWC millibars

0.00 1.02 150,000 4,248 7,500 212.4 20:1 1.7 4.1

0.25 1.03 152,546 4,320 7,563 214.2 20:1 1.7 4.2

1 1.08 160,183 4,536 7,750 219.5 21:1 1.8 4.4

10 1.71 251,833 7,131 9,718 275.2 26:1 2.8 7.0

25 2.74 404,582 11,457 12,317 348.8 33:1 4.5 11.2

50 4.46 659,165 18,665 15,722 445.2 42:1 7.3 18.2

75 6.19 913,747 25,874 18,511 524.2 49:1 10.1 25.3

100 7.91 1,168,330 33.,083 20,931 592.7 56:1 13.0 32.3

125 9.64 1,422,912 40,292 23,099 654.1 62:1 15.8 39.4

200 14.81 2,186,660 61,919 28,635 810.9 76:1 24.3 60.5

300 21.71 3,204,990 90,755 34,668 981.7 92:1 35.6 88.7

400 28.60 4,223,320 119,591 39,796 1,126.9 106:1 46.9 116.8

500 35.50 5,241,650 148,427 44,335 1,255.4 118:1 58.2 145.0

600 42.40 6,259,980 177,263 48,451 1,372.0 129:1 69.5 173.2

700 49.29 7,278,310 206,099 52,243 1,479.4 139:1 80.8 201.3

800 56.19 8,296,640 234,935 55,778 1,579.5 149:1 92.1 229.5

900 63.08 9,314,969 263,771 59,102 1,673.6 158:1 103.5 257.7

1,000 69.98 10,333,299 292,606 62,249 1,762.7 166:1 114.8 285.9

1,100 76.88 11,351,629 321,442 65,244 1,847.5 174:1 126.1 314.0

1,200 83.77 12,369,959 350,278 68,108 1,928.6 182:1 137.4 342.2

1,300 90.67 13,388,289 379,114 70,856 2,006.4 189:1 148.7 370.4

1,400 97.57 14,406,619 407,950 73,501 2,081.3 196:1 160.0 398.5

The above table is based on standard conditions of 14.73 Psia and 60ºF for 0.60 specific gravity gas.Supercompressibility not included.

 

Page 22: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Standard Gas Turbine Meter Dimensional Information(inches)

Size ANSIClass

WorkPres.

A B C D Bolt CircleDiameter

Flange Bolt Holes Approx.Weight

    (PSIG)           No. Diameter (Lbs.)

  125 175 9 14 17 5/8 ? 7 1/2 8 1/2 38

  150 285 9 15 1/2 17 5/8 1/16 7 1/2 8 3/4 125

4" 300 740 10 15 1/2 17 5/8 1/16 7 7/8 8 7/8 130

  600 1480 10 3/4 15 1/2 17 5/8 1/4 8 1/2 8 1 160

  900 2220 11 1/2 17 1/2 18 3/8 1/4 9 1/4 8 1 1/4 260

 

Size ANSIClass

WorkPres.

A B C D Bolt CircleDiameter

Flange Bolt Holes Approx.Weight

    (PSIG)           No. Diameter (Lbs.)

  125 175 11 16 19 3/8 ? 9 1/2 8 5/8 76

  150 285 11 22 1/2 19 3/8 1/16 9 1/2 8 7/8 270

6" 300 740 12 1/2 22 1/2 19 3/8 1/16 10 5/8 12 7/8 280

  600 1480 14 22 1/2 19 3/8 1/4 11 1/2 12 1 1/8 365

  900 2220 15 24 20 1/4 1/4 12 1/2 12 1 1/4 450

 

Size ANSIClass

WorkPres.

A B C D Bolt CircleDiameter

Flange Bolt Holes Approx.Weight

    (PSIG)           No. Diameter (Lbs.)

  125 175 13 1/2 21 19 5/8 ? 12 3/8 8 3/4 137

  150 285 13 1/2 27 1/4 19 5/8 1/16 11 3/4 8 7/8 530

Page 23: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

8" 300 740 15 27 1/4 19 5/8 1/16 13 12 1 550

  600 1480 16 1/2 27 1/4 20 5/8 1/4 13 3/4 12 1 1/4 625

  900 2220 18 1/2 27 1/4 21 5/8 1/4 15 1/2 12 1 1/2 850

 

Size ANSIClass

WorkPres.

A B C D Bolt CircleDiameter

Flange Bolt Holes Approx.Weight

    (PSIG)           No. Diameter (Lbs.)

  150 285 19 36 23 7/8 1/16 17 12 1 605

12" 300 740 20 1/2 36 24 3/8 1/16 17 3/4 16 1 1/4 730

  600 1480 22 36 25 1/4 19 1/4 20 1 3/8 1100

 

Page 24: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Standard Gas Turbine Meter Dimensional Information(Millimeters)

Size ANSIClass

WorkPres.

A* B C D Bolt Circle*Diameter

Flange Bolt Holes* Approx.Weight

    (kPa.)           No. Diameter (kg.)

  125 1200 280 355 447 ? 190.5 8 M18 17

100mm 150 1900 280 394 447 1.59 190.5 8 M18 57

4" 300 5000 255 394 447 1.59 200.0 8 M20 59

  600 10,000 275 394 447 6.35 216.0 8 M24 73

  900 15,300 295 444 466 6.35 235 8 M30 118

 

Size ANSIClass

WorkPres.

A* B C D Bolt Circle*Diameter

Flange Bolt Holes* Approx.Weight

    (kPa.)           No. Diameter (kg.)

  125 1200 280 407 340 ? 241.5 8 M20 35

150mm 150 1900 280 572 340 1.59 241.5 8 M20 123

6" 300 5000 320 572 340 1.59 270.0 12 M20 127

  600 10,000 355 572 340 6.35 292.0 12 M27 166

  900 15,300 380 610 514 6.35 317.5 12 M30 204

 

Size ANSIClass

WorkPres.

A* B C D Bolt Circle*Diameter

Flange Bolt Holes* Approx.Weight

    (kPa.)           No. Diameter (kg.)

  125 1200 345 533 499 ? 298.5 8 M20 62

200mm 150 1900 345 692 499 1.59 298.5 8 M20 240

8" 300 5000 380 692 499 1.59 330.0 12 M24 250

Page 25: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

  600 10,000 420 692 514 6.35 349.0 12 M30 284

  900 15,300 470 692 549 6.35 393.5 12 M36 386

 

Size ANSIClass

WorkPres.

A* B C D Bolt Circle*Diameter

Flange Bolt Holes* Approx.Weight

    (kPa.)           No. Diameter (kg.)

300mm 150 1900 485 914 606 1.59 432 12 M24 274

12" 300 5000 520 914 619 1.59 451 16 M30 331

  600 10,000 560 914 635 6.35 489 20 M33 499

 

Page 26: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Parts List 

PARTS LISTA Housing BodyB Cover PlateC Internal HousingD External OilerE Pin Boss SpacerF Coil Tube FittingG Pressure Tap PlugH Rotor HubJ RotorK BearingsL Magnet Housing w/Magnets

Page 27: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

M Drain PlugN Shaft Coil HousingO Coil Cover Tube AssemblyP Spring PlungerQ Flow DeflectorR Swagelok Tube Fitting

 

Page 28: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Preamplifiers and TransmittersNote:  Detailed information and drawings can be found in the Preamplifier section

MODEL 1816 SIGNAL PREAMPLIFIERThe Daniel Model 1816 Preamplifier is a 3-wire device which transmits up to 5,000 feet. Connections are"Power +," "Power -" (supplied from the readout device) and "Signal." The Model 1816 has its own regulator,operates with any DC voltage greater than 19 volts and less than 40 volts, and is insensitive to pipelinevibrations and electrical "noise." All Daniel Gas Turbine Meters are equipped with a Model 1816 Preamplifierunless they are used in conjunction with the Model MRT-94 Flow Rate Totalizer, or the Model 1803Factoring/Readout Totalizer. The Model 2482 Solarflow Plus uses the Model 1882 listed below.

MODEL 1882 SIGNAL PREAMPLIFIERThe Daniel Model 1882 Preamplifier is identical in physical layout and hook up to the 1816 Preamplifier exceptthat it requires much lower pressure (5-9 volts). The Model 1882 is used exclusively with the Model 2482Solarflow Plus. (Remove capacitors C21 and C22.)

MODEL 2415 B PREAMPLIFIERCenelec approved, intrinsically safe preamplifiers.

MODEL 224 STATIC PRESSURE TRANSDUCERFour-wire transducer uses a bonded meter foil strain gage, intended to use with Solarflow instruments only.Available for pressure ranges from 0-25 psig to 0-500 psig. Accuracy to ±0.25%.

MODEL 1151 GP STATIC PRESSURE TRANSMITTERThis transmitter is compatible with 2-wire systems, has external span and zero adjustments, and featuresexplosion-proof, weatherproof construction. The unit ranges from 5 in. H20 to 2,500 psig and is impervious tovibration. It has an accuracy of ±0.25.

MODEL 415 TEMPERATURE TRANSMITTER2-wire transmitter uses a platinum element in a Wheatstone Bridge circuit. Unit has removable electronics andexplosion proof cap, accuracy of ±0.05% full scale.

MODEL 400 LP TEMPERATURE TRANSDUCERThis transducer uses a 500 ohm platinum element in a special low power consumption bridge circuit. The 400LP is intended for use with Solarflow and 2270 Series instruments only.

 

Page 29: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Preamplifiers

Standard Preamplifiers

Universal Preamplifier, Data Sheet, (pdf format, 76k)

Page 30: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Preamplifiers Brochure

Benefits of a Preamplifier

Model Numbers/Specifications

Wiring Diagrams

1815A Multiplying Preamplifier for Liquid

1816 for Gas Turbine Meters

1817X1 and 1817X2 for (LowTemp)Bi-Directional Liquid

1818A and 1818AX2 for (Low Temp) Liquid

1818MG for Mini Gas Turbine Meter

1819A for High Resolution Liquid

1882 for SolarFlow Plus Model 2482, GasTurbine Meter

Go directly to the Product Discussion forum forthis product.

 

Page 31: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Benefits of a PreamplifierA turbine metering system will usually consist of several elements--the turbine meter, the readout instrument,and the interconnecting cable (when the readout instrument is not directly mounted on the meter). Theinterconnecting cable may be as short as 2 of 3 feet (approx. 1 meter) or as long as 5,000 feet (approx. 1500meters), using Belden 8770 or 9460 Type Cable terminated into Daniel equipment. A turbine meter pickup coilwith the sensitivity to provide an accurate pickup of turbine rotor travel has the electrical characteristics of highimpedance and low voltage output. But, electrical noise-free pulse transmission requires the opposite lowimpedance and high voltage. This is the function of the signal preamplifier. Located only inches (millimeters)from the coil, it amplifies and strengthens the turbine meter output for reliable connection to various readoutinstruments.

Page 32: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model Numbers/SpecificationsMODEL NUMBERSAvailable with or without Explosion Proof Enclosure

Preamplifier Model No. 1815A* 1816 1817X11817X2

1818A1818AX2

1818MG 1819-4 1882

Measurement Service Hi ResolutionLiquid

Gas Bi-directionalLiquid

General PurposeLiquid

Mini Gas Meter Hi ResolutionLiquid

GasModel 2482 Only

Number of Inputs(pickup coils)

1 1 2 1 1 2 1

Pickup Coil Number PC-13-74G Part of Gas Meter PC-13-74G PC-13-74G Part of Gas Meter PC-13-74G Part of Gas Meter

Weight (Approximate) 12 oz.340 gm.

8 oz.230 gm.

8 oz.230 gm.

8 oz.230 gm.

8 oz.230 gm.

12 oz.340 gm.

8 oz.230 gm.

Mounting 2 Screws4-40 x 1 1/4

BHMS

2 Screws4-40 x 1 1/4

BHMS

2 Screws4-40 x 1 1/4

BHMS

2 Screws4-40 x 1 1/4

BHMS

2 Screws4-40 x 1 1/4

BHMS

2 Screws4-40 x 1 1/4

BHMS

2 Screws4-40 x 1 1/4

BHMS

Input Voltage 15V to 30V dc 12V to 15V dc or19V to 40V dc

12V to 15V dc 15V to 30V dc 15V to 30V dc 15V to 30V dc 5-9 VDC

Input Current 10 mA dc 20 mA dc 30 mA dc 10 mA dc 10 mA dc 10 mA dc 2 mA dc

Temperature RangeºF (ºC)

0 to 160(-17 to 71)

0 to 140(-17 to 60)

1817X1:0 to 160

(-17 to 71)1817X2

-40 to 160(-40 to 71)

1818A:0 to 160

(-17 to 71)1818AX2-40 to 160(-40 to 71)

0 to 160(-17 to 71)

0 to 160(-17 to 71)

-20 to 160(-30 to 71)

Frequency Response 10 Hz to 1500 Hz 1 Hz to 1500 Hz 10 Hz to 1500 Hz 10 Hz to 1600 Hz 10 Hz to 510 Hz 30 Hz to 1200 Hz 1 Hz to 5000 Hz

Output Impedance 300 ohms 330 ohms 50 ohms 330 ohms 330 ohms 300 ohms 100 ohms

Output VoltageFdc referenced

to common

Square Wave12V

Square Wave1.5V to 13.5V

Square Wave11V to 14V

Square Wave12V

Square Wave12V

Square Wave12V

Square Wave 6V

Input SensitivitymV rms

27 mV 1.25 mVminimum

27 mV 27 mV 4 mV minimum 27 mV 5 mV

*Not to be used with 24" or 4" rim type PT meters.

Page 33: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model 1815A Multiplying PreamplifierDIMENSIONS AND WIRING

Page 34: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model 1816 Gas Turbine Meter PreamplifierModel 1816 Gas Turbine Meter Preamplifier

This unit is used with Daniel Gas Turbine Meters which require electrical output. Aunique integrated circuit converts rotor velocity to rotor position so that the electricaloutput is immune to pipleline vibration and mechanical noise. The preamplifier has abroad dynamic range to match the wide flow range a gas turbine meter can measure.

DIMENSIONS AND WIRING

Page 35: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model 1817X1 & 1817X2 (Low Temp)Bi-Directional Preamplifier

Model 1817X1 &1817X2 (Low Temp) Bi-Directional Preamplifier.

This preamplifier is used with bi-directional liquid flow turbine meters and requires twopickup coils mounted on the meter 90 electrical degrees apart. The preamplifier hasthree outputs: output pin D pulses only when flow is from one direction; output pin Epulses only when flow is from the opposite direction; convenience pin F outputs asteady dc voltage, + 12v dc or OV dc, depending upon the direction of flow.

DIMENSIONS AND WIRING

Page 36: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model 1818A & 1818AX2 (Low Temp)Liquid Turbine Meter Preamplifier

Model 1818A & 1818AX2 (Low Temp) Liquid Turbine Meter Preamplifier.

This unit is suitable for general purpose liquid measurement, using Daniel "PT" or "CR"Meters. It will function with any turbine meter whose pickup coil meets the electricalinput requirements. The preamplifier will accept input power from 15 to 30 volts anddeliver a signal swing of 12 volts. It has dc isolation from the pickup coil, making itsuitable for use with cathodic protection systems.

DIMENSIONS AND WIRING

Page 37: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model 1818MG Mini Gas Meter PreamplifierDIMENSIONS AND WIRING

Page 38: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model 1819-A Hi-Resolution PreamplifierModel 1819-4 Hi-Resolution Preamplifier.

This unit is used with Daniel "PT" Meters and requires two pickup coils mounted 90electrical degrees apart. The preamplifier has two outputs, XI and X2. XI operates atthe pulse rate of the primary pickup coil A. X2 is the sum of the A coil and the B coil. Aninternal circuit detects a coil open circuit and shuts down the X2 output. The Model1819-4 has dc isolation from the pickup coils, making it suitable for use on cathodicallyprotected systems. When used as a signal comparator, a failure of either coil, opencircuited or shorted, can be detected and alarmed.

DIMENSIONS AND WIRING

Page 39: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Model 1882 Gas Turbine Meter Preamplifierfor Solarflow-Plus Model 2482Model 1882 Gas Turbine Meter Preamplifier for Solarflow-Plus Model 2482This preamplifier is used with Daniel Gas Turbine Meters that are supplied with Model 2482 Solarflow-PlusBattery Powered RTU's. The Model 1882 is an ultra low power preamplifier that is powered by the Model 2482.The Model 1882 is identical in physical appearance and hook up to the Model 1816 and is for use only withDaniel Gas Turbine Meter Model 2480 Measurement Systems.

DIMENSIONS AND WIRING

For dimensions and wiring, see Model 1816 Gas Turbine Meter Preamplifier

Page 40: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

UNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1

March 31, 1998

Daniel Measurement and ControlP.O.Box 19097

Houston, TX 77224(713) 467-6000

Page 41: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 2 of 13

1. INTRODUCTIONThe Weston Technology Universal Preamplifier (Preamp) converts the low level signalfrom a turbine meter inductive pickup to high level pulses. It is distinguished by thefollowing features:

• Tailored Frequency Response

The sensitivity of the Preamp rolls off as frequency increases, matching thecharacteristic output of a turbine meter with inductive pickup. High sensitivity at lowfrequencies allows the turbine meter to operate at its lowest possible flow rates.Reduced sensitivity at high frequencies prevents spurious counting due to RFI andtransients.

• Common Mode Rejection

The Preamp employs a differential amplifier, which responds only to differencesbetween the COIL+ and COIL- wires. Spurious signals such as 60Hz, RFI, or transientstypically appear on both wires as “common mode” signals. The Preamp is hundreds oftimes less sensitive to common mode signals than to the “normal mode” signalsproduced by the meter.

• Dual Outputs

With its dual outputs, the Preamp works with virtually any end device. One outputswings from 0V to 5V regardless of the power supply voltage, and is suited for mostinputs with thresholds of 4V or less. An open collector output swings from 0V to anyavailable power supply voltage up to 36V, sinking up to 50mA.

• Wide Power Supply Range, Low Power Operation

The Preamp operates with any power supply voltage from 5.4 to 36V and requires lessthan 1mA. It can be added to virtually any system without special power conditioning,and typically with no impact on power system requirements.

• Bullet-Proof I/O

The Preamp tolerates continuous short circuits to ground or up to ±36V on any fieldwiring terminal without damage. All field wiring terminals are protected against ESD(electrostatic discharge) and transients.

• Rugged and Convenient Packaging

The Preamp is fully encapsulated in a compact package suitable for mounting on apanel or in a standard 3” ID explosion-proof housing. Pluggable cage-clamp typeconnectors allow convenient, reliable connections without the need for lugs. Terminalsare labeled with signal names to simplify installation.

Page 42: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 3 of 13

2. FIELD WIRINGThe Preamp has six field wiring terminals, designated as follows:

J1 SIGNAL DESCRIPTION1 PWR Power supply input (5.4 to 36VDC)2 COMMON Power supply and signal return3 0-5V OUT Signal output which swings from 0V to 5V4 OC OUT Open collector output which swings from 0V to a pullup voltage5 COIL+ Connects to one side of the pickup coil6 COIL- Connects to the other side of the pickup coil. If polarity is not

indicated for the coil, COIL+ and COIL- are interchangeable.

Field wiring connects to a pluggable cage-clamp type connector. The connectoraccepts wire sizes from 24AWG to 14AWG, with a recommended strip length of ¼”.

The Preamp conditions the low-level output of the meter/pickup coil and produces acorresponding high-level output for an end device (the end device is a readout, flowcomputer, PLC, or other device which acquires the meter output). Where possible, thePreamp should be located close to the meter. Use twisted-pair wiring if the cablebetween the pickup coil and Preamp is longer than a few feet. Do not run the pickupcoil wiring together with other wiring which may cause interference, such as 120VAC orsignals which switch high voltage or current levels. Refer to section 3 of this documentfor installations where high levels of EMI (electromagnetic interference) may be present.

There are two basic wiring configurations used between the Preamp and the enddevice. Figure 1 below shows the preferred configuration, using the Preamp 0-5Voutput. In this configuration, the end device receives a signal which swings nominallyfrom 0V to 5VDC. Use this configuration if the end device has a threshold of 4.2V orless and input current of 0.5mA or less. The 0-5V output is preferred because it issimpler to use and dissipates less power.

Page 43: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 4 of 13

POWER ( 5.4 TO 36VDC)

PICKUPCOIL

T W I S T E DPAIR

W I R I N G

MAX 5000 FEET (1524 METERS)

MAX 100 FEET(30 METERS)

3 -CONDUCTOR SHIELDED CABLE,2 4 A W G O R L A R G E R

C O M M O N

SIGNAL INPUT(0 TO 5V)

CONNECT SHIELD ONLY AT END DEVICE

P W R

GND

0-5 OUT

OC OUT

COIL+

COIL-

PREAMPLIFIER

END DEVICE

0-5 OUT MAX 0 .5mA

Figure 1: 0-5V Output Wiring

The 0-5V output is not suitable if the end device has a threshold greater than 4.2Vand/or its input current exceeds 0.5mA. Figure 2 below shows an alternate field wiringconfiguration, using the Preamp OC (open-collector) output. This output is actuallydriven by a FET (Field Effect Transistor), and is properly called an open-drainconfiguration. Because the Preamp output works the same as an open collector output,the more familiar term is used. This output swings between 0V and a pullup voltage.

POWER ( 5.4 TO 36VDC)

PICKUPCOIL

2 4 A W G O RL A R G E R

TWISTED PA IR

MAX 1000 FEET (305 METERS)

MAX 100 FEET(30 METERS)

3 -CONDUCTOR SHIELDED CABLE,2 4 A W G O R L A R G E R

C O M M O N

SIGNAL INPUT(OPEN COLLECTOR)

CONNECT SHIELD ONLY AT END DEVICE

P U L L U PRESISTOR

OC OUT MAX 50mA

END DEVICE

PREAMPLIFIER

P W R

GND

0-5 OUT

OC OUT

COIL+

COIL-

Figure 2: OC Output

The OC OUT FET is turned on when the 0-5V output is at the 5V level. When the FETis turned on, OC OUT is connected to COMMON through a resistance of less than 10ohms. When the FET is turned off (0-5V output at the 0V level), OC OUT is essentiallyan open circuit. A single power supply can provide both power and the pullup voltage.Note that while the pullup voltage has the same range as the power supply voltage, thetwo do not have to be the same. For example, the power supply may be 12V and thepullup voltage 24V, or vice-versa.

Page 44: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 5 of 13

2.1 Choosing a Pullup ResistorA pullup resistor is required when using the OC output. A 2K ohm, 3W resistor willserve most applications. Some rudimentary analysis is necessary to identify theoptimum resistor for a given application. A qualified engineer or technician shouldreview the selection to ensure compliance with Preamp and end device specifications.

The OC output is conservatively rated to sink a maximum of 50mA. This sets a lowerlimit on the pullup resistor value versus the power supply voltage, as illustrated in Figure3 below.

0

100

200

300

400

500

600

700

800

Maximum Pullup Voltage (V)

Min

imum

Pul

lup

Res

isto

r V

alue

(oh

ms)

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

Pul

lup

Res

isto

r P

ower

D

issi

patio

n (W

)

6 9 12 15 18 21 24 27 30 33 36

Figure 3: Pullup Resistor Parameters

The right axis in Figure 3 shows the power dissipation through the pullup resistor.Locate the resistance value on the left axis then find the corresponding powerdissipation directly across from the resistance value. For example, at 24V the minimumpullup resistor value is 480 ohms and the power dissipation is 1.2W. The pullupresistor should be rated for at least 2-3 times this value. Normal power dissipationaverages half the indicated value when the output is switching, but if the meter stopsturning or is disconnected, the OC output may remain in a state where dissipation iscontinuous.

A practical upper limit on the pullup resistor value is dictated by output rise time. Whenthe FET turns off, the pullup resistor causes OC OUT to rise toward the pullup voltage.Rise time is how long it takes for OC OUT to go from 10% to 90% of the pullup voltageafter the FET turns off. The corresponding value, fall time, measures the time for OCOUT to go from 90% to 10% of the pullup voltage when the FET turns on. Fall time isalways much less than rise time, and is not affected by the pullup resistor value.

For most applications, rise time depends on the pullup resistor value, cable length, andend device input capacitance. An end device input designed to accept “high-speed”

Page 45: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 6 of 13

signals (up to 5KHz for the Preamp) typically has negligible input capacitance. Figure 4predicts the approximate rise time versus cable length with a 2K ohm pullup resistor,excluding end device input capacitance.

0

25

50

75

100

125

150

175

200

225

250

100 200 300 400 500 600 700 800 900 1000

Cable Length (ft)

Ris

e T

ime

(uS

)

Figure 4: Rise Time vs. Cable Length (2K Pullup)

Every 6nF of end device input capacitance is equivalent to 100 feet of additional cablelength when using Figure 4. For pullup resistor values other than 2K ohms, or for cablelengths not shown in the chart, use the following formula:

tR = 0.12 * R * L where

tR is the predicted rise time in uSR is the pullup resistor value in K ohmsL is the cable length in feet

The maximum acceptable rise time depends on the end device input characteristicsand the highest expected signal frequency. Consult the end device documentation todetermine if a maximum rise time is specified for the input used with OC OUT.

The maximum rise time allowed should be the lesser of 1) the end device rating, and 2)the value given by the following calculation:

Page 46: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 7 of 13

tMAX = 0.3 / f where

tMAX is the maximum acceptable rise time in Sf is the maximum turbine meter output frequency in Hz

For example, if the maximum frequency expected from the meter is 4KHz, the rise timeshould not exceed 0.3 / 4000 = 75uS. Referring to Figure 4, we see that the maximumcable length for 75uS rise time with a 2K pullup is about 300 feet. If we need to use1000 feet of cable, we can calculate the required pullup resistance using the followingformula:

RP = 2 * L1 / L2 where

RP is the new pullup value in K ohmsL1 is the length from Figure 4L2 the desired length

From the above formula, we determine that RP = 2 * 300 feet / 1000 feet = 0.6K or 600ohms. We refer to Figure 3 and determine that the maximum allowable pullup voltagewith a 600 ohm resistor is 30V. If our application uses a pullup voltage of 12V, thepower dissipation of the pullup resistor is E2 / R = 122 / 600 = 0.24W. A 600 ohm 1Wpullup resistor is a conservative choice. Average power dissipation of the pullupresistor during operation will be 0.24W / 2, or 0.12W.

Page 47: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 8 of 13

3. INSTALLATIONMount the Preamp inside a building or enclosure where it is not directly exposed toweather, as close as practical to the meter. If the Preamp will be exposed to significantsources of EMI, such as high-powered mobile radios or other nearby transmitters, thePreamp should be installed in a junction box which is mounted directly on the turbinemeter as shown in Figure 5 below.

Figure 5: Recommended Mounting

All wiring to the end device (PWR, GND, and 0-5 OUT or OC OUT) should be routedthrough conduit in environments where high levels of EMI are expected.

Page 48: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 9 of 13

Figure 6 below shows front and top views of the Preamp, approximately actual size.

2.50

Ø 0.12 ID

1.90

0.75

1.50

2 PLCS

0.50

1.4

PW

R

GN

D

0-5 OU

T

OC

OU

T

CO

IL-

CO

IL+

UNIVERSAL PREAMPLIFIER

Figure 6: Dimensions

The Preamp is designed to fit in a standard 3” ID explosion-proof housing, with orwithout a mounting bracket.

Page 49: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 10 of 13

4. ELECTRICAL CHARACTERISTICSAll specifications apply over the operating temperature range unless otherwiseindicated.

4.1 Power SupplyThe Preamp requires a DC power source to operate. The power supply positive outputconnects to the PWR terminal on the Preamp. The power supply return connects to thePreamp COMMON terminal. The COMMON terminal serves as a return path for power,0-5 OUT, and OC OUT.

Power Supply Voltage (DC, operating) 5.4V min36V max

Power Supply Current 0.7mA typ1mA max

4.2 Coil InputThe two pickup coil leads connect to the Preamp COIL+ and COIL- terminals. The coilmay have a third lead, typically connected to the coil housing. Do not connect this leadto the Preamp. The coil leads are interchangeable. Each coil input tolerates up to ±36V relative to COMMON. The total voltage between COIL+ and COIL- should notexceed 36V.

Refer to Section 4.5 for a discussion of the coil input frequency response.

4.3 0 to 5V OutputThe 0-5 OUT terminal swings between 0V and 5V nominally, at the same rate as thesignal from the pickup coil. If no signal is present at the coil input, the output is stableat either 0V or 5V.

0-5 OUT Voltage (low) 0V min0.5V max

0-5 OUT Voltage (high) 5.0V typ (no load)4.8V typ (0.5mA load)4.2V min5.5V max

0-5 OUT Current (low) 0.5mA max0-5 OUT Current (high) -0.5mA max

If 0-5 OUT is connected to a power source due to a wiring error, the output may sinkseveral amps for a few milliseconds before the protection circuit activates. After a fewmilliseconds, if the fault is still present, 0-5 OUT will stabilize at about 20mA. Theoutput returns to normal operation within seconds after the fault is removed.

Page 50: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 11 of 13

4.4 Open Collector OutputThe OC OUT terminal actually uses an open-drain configured FET (Field EffectTransistor). When 0-5 OUT is high, the FET is turned on, and when 0-5V is low, theFET is turned off.

OC OUT Leakage < 10uA typ0.1mA max

OC OUT Resistance (on) 5 ohms typ (25° C)10 ohms max

OC OUT Pullup Voltage 36V maxOC OUT Pullup Current 50mA max

OC OUT should connect to a power source through a pullup resistor. The resistorvalue must be selected to limit pullup current to 50mA or less. Refer to Section 2.1 forinformation about choosing a pullup resistor. If OC OUT is connected directly to apower source due to a wiring error, the output may sink several amps for a fewmilliseconds before the protection circuit activates. After the protection circuit activates,if the fault is still present, OC OUT will stabilize at about 20mA. The output returns tonormal operation within seconds after the fault is removed.

4.5 Frequency ResponseThe output of the turbine meter pickup coil is approximately a sine wave. For a givenfrequency, the turbine meter output must reach a minimum amplitude in order for thePreamp to respond accurately. If the signal is below this minimum amplitude, thePreamp may not respond at all, or it may drop pulses on its output. If the signal equalsor exceeds this minimum amplitude, the Preamp output will correspond to the inputsignal.

Figure 7 shows the minimum input amplitude versus frequency for the Preamp. Thecurve is produced by a simple formula: Amplitude = (0.06 * Frequency) + 1. Amplitudeis expressed in mVrms, and frequency is expressed in Hertz.

Page 51: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 12 of 13

1.0

10.0

100.0

1000.0

1 10 100 1000 10000

Frequency (Hz)

Min

imum

Am

plitu

de (

mV

rm

s)

Figure 7: Frequency Response

5. ENVIRONMENTOperating temperaturerange

-40 to +70° C

Operating humidity range 5% to 95% RH non condensing

Transient susceptibility All field connected circuits are designed to meetthe requirements of ANSI/IEEE C37.90.1-1989(formerly IEEE 472) for surge withstand capability.

Vibration Effect 10 to 500 Hz at 1 g on any axis per SAMA PMC-31-1 without damage or impairment.

ESD susceptibility Field connected circuits are designed to meet therequirements of IEC 801-2 for ESD withstandcapability up to 10KV.

EMI compatibility Designed to meet the susceptibility requirementsof IEC 801-3 level 2 (3V/M) from 500KHz to500MHz when installed per section 3 of thisdocument.

Designed to meet FCC Rules Part J, Subpart 15,Class A for radiated emissions.

Page 52: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and ControlUNIVERSAL PREAMPLIFIER DATA SHEET

REVISION 1.1 3/31/98 Page 13 of 13

Hazardous locations Designed to meet NFPA and UL requirements forinstallation in Class I, Divisions 1 and 2, Groups C& D hazardous locations.

Designed to fit in commonly available explosion-proof junction boxes.

While the Preamp itself is designed to meet the requirements for both nonincendiveand intrinsically safe installations, it is the responsibility of the user to ensure that thecombination of pickup coil, Preamp, end device, power supply, and wiring is suitable forthe location.

The total Preamp capacitance is 70uF. It has no inductive components and no internalpower sources. There is no significant temperature rise during normal operation.

Page 53: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Length of Meter TubesLENGTH OF METER TUBESGas turbine meter tubes can be supplied with any type of line connection, in special materials, and in anyspecified length. Illustrated are a two-section meter tube with a line model straightening vane and one with aflange model vane. The flange model vane is recommended as it can be easily removed for inspection; and, byusing the flanged tube with the spacer and jackscrews, the meter also can be easily removed from the line.Beveled outer ends are standard but other connections can be supplied.

NOTE: Daniel recommends installation of strainers upstream of the meter.

NominalLine Size

ANSIClass

DimensionU

DimensionA

DimensionD

DimensionOA

  125 3'-10" 1'-2" 2'-0" 7'-0"

  150 3'-8 1/2" 1'-3 1/2" 2'-0" 7'-0"

4" 300 3'-8 1/2" 1'-3 1/2" 2'-0" 7'-0"

  600 3'-8 1/2" 1'-3 1/2" 2'-0" 7'-0"

  900 3'-6 1/2" 1'-5 1/2" 2'-0" 7'-0"

  125 5'-8" 1'-4" 3'-0" 10'-0"

  150 5'-1 1/2" 1'-10 1/2" 3'-0" 10'-0"

6" 300 5'-1 1/2" 1'-10 1/2" 3'-0" 10'-0"

  600 5'-1 1/2" 1'-10 1/2" 3'-0" 10'-0"

  900 5'-0" 2'-0" 3'-0" 10'-0"

  125 7'-1/4" 1'-9" 4'-0" 13'-0"

  150 6'-8 3/4" 2'-3 1/4" 4'-0" 13'-0"

8" 300 6'-8 3/4" 2'-3 1/4" 4'-0" 13'-0"

  600 6'-8 3/4" 2'-3 1/4" 4'-0" 13'-0"

  900 6'-8 3/4" 2'-3 1/4" 4'-0" 13'-0"

  150 10'-0" 3'-0" 5'-0" 18'-0"

12" 300 10'-0" 3'-0" 5'-0" 18'-0"

  600 10'-0" 3'-0" 5'-0" 18'-0"

Page 54: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel
Page 55: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Alignment of Meter TubesTHE DANIEL METHOD OF ALIGNING METER TUBESAccurate measurement demands proper alignment of turbine meter flanges with meter tube flanges. Properalignment throughout the metering section will prevent offsets, steps, and gasket protrusion into the bore, all ofwhich could disturb the flow pattern.

On all meters and tubes with raised face flanges, Daniel drills three knock-out dowel pin holes in each flange toaid in alignment.

After bolt-up, dowel pins should be removed and the holes packed with grease.

Page 56: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Recommended Piping LayoutsRECOMMENDED PIPING LAYOUTS

Maximum accuracy of a turbine meter requires that the fluid stream be free of rotational components. For best results, it isrecommended that the meter be equipped with adequate upstream fluid straightening devices. Flow control valves should belocated downstream of the meter.

Test results have shown that the normal installation ("A" above) is suitable for most installations encountered in meter stationdesigns. The use of straightening vanes is recommended and they should be installed at a minimum of five pipe diametersupstream of the turbine meter inlet.

For maximum accuracy in uncertain installations ("B" above), meter tube lengths as recommended in the AGA GasMeasurement Committee Report No. 7 for turbine meters will provide a safe standard.

Both installations recommend the use of a critical flow control orifice. This orifice provides a controlling restriction for the gasturbine meter, limiting its possible overrange to approximately 25% over maximum rating.

NOTE: A critical flow control orifice creates a high differential pressure resulting in 50% permanent pressure loss at 25% overmaximum operating range of the turbine meter.

Page 57: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Page 58: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Strainers (Cone and Basket)

STRAINERS (Cone and Basket)Daniel offers Cone-type Strainers which are installed in the spool section upstream of the meter tube. Thesestrainers are designed to catch heavy particles in the flow line and have 1/8" diameter perforations on 3/16"centers. Daniel also offers a Basket-type Strainer which allows ease of access during maintenance. Thesestrainers are installed adjacent to the spool section upstream of the meter tube and are available in all ratings.

 

Page 59: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Flow Computing Systems

Page 60: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel
Page 61: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

MULTIPLE TUBES WITH FLOW CORRECTED FOR P, T OR P1 AND Fpv

...........................

Page 62: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Gas Flow InstrumentationTHE 2500 SERIES RTU

The 2500 Series RTU is a line powered instrument for measuring status and control.The 2500 is user configurable to perform the functions required for flowmeasurement applications in addition to a variety of process applications.

Check out our NEW 2500 Turbo Upgrade-486/100Mhz

The 2500 Series is compatible with most process flow-meter and transmitter inputsand provides for configuring, reporting, and host computer communications.

The 2500 can provide AGA 3 (API 2530), ISO 5167, AGA 5, AGA 7, API 1101, andAPI 2534 flow and totalizer functions. It also has an extensive set of compensationand signal processing subroutines to linearize, compensate, integrate, totalize,control, batch, and log.

The CONFIG 25 program--which runs on an IBM PC or IBM-compatiblecomputer--allows an engineer or technician who understands an application and isfamiliar with programming techniques to define the configuration of the 2500 Series.

Additionally, the instrument can be used independently or combined with otherintelligent Daniel instruments in systems applications.

RATE AND TOTAL FLOW

The Model 2235 FLOWMASTER computer is designed for natural gasmeasurement. It features single-chip microprocessor design and uses digitaltechniques for gas measurement.

The Model 2235 features alphanumeric display, nonvolatile memory, power-upmemory check, and watchdog timer. The operator uses front panel switches to enterkey operational parameters in a conversational mode. During operation, the operatorcan display any variable with no interruption to the computer.

During the calibration of transducers, measurement still continues. Before calibrationof the transducer, the operator reads its output and enters this value into thecomputer via the front panel keyboard. The Model 2235 uses this fixed value in themeasurement process until the transducer is calibrated and returned on line.

BATTERY POWERED INSTRUMENTS

Page 63: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Flow Totalization. The MRT-94 provides flow rate and totalization. Batterypowered, operator configurable, pulse output, 4-20 MA output, security lock outcode, 10 point linearization, explosion proof housing. Ideal for demanding locations.

Model 2480 Solarflow Plus. The Solarflow Plus is a battery powered solar chargedsingle tube RTU for the measurement of natural gas, via one impulse type meter.The Model 2480 uses AGA 7 and NX 19 calculations, along with 1/2 secondtransmitter sampling, and flow extension calculations to provide the highestmeasurement accuracy available. Up to 35 days of data can be stored or transmittedfor reporting, via the hand held data terminal, telephone, radio, satellite, or fiber opticlinks. Audit trail, data editing, and as frequent as five minute data averaging isavailable.

...........................

Page 64: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Flow Computers Brochures

Series 3000

SolarFlow Plus Computer

2500 Turbo Flow Computer

Page 65: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Series 3000 Flow Computer and RTU Communication System

© 1998 Daniel Measurement and Control

The Series 3000 system is designed tohandle a multitude of applications. FromOrifice to Ultrasonics, this RTU has noequal. Perfect for Solar Power:

Compressor Monitoring●

Pipeline Leak Detection●

Storage Fields (Bidirectional using a singleSmart P/DP)

Single Tube AGA3 - Expandable to 3 Tubes●

Single Tube AGA7 - Expandable to 3 Tubes●

Ultrasonic Digital Interface

AGA 9 Gas Ultrasonics (Full Digital or Pulse Interface)●

Liquid Measurement (Ethylene)●

RTU Configurations

The 3000 can used for orifice or pulse type applications, while the 3405 has beenemphasized to handle gas ultrasonic meters. Each model retains the same circuit boards,only the flash program memory is unique.

Custom Applications are exactly what this RTU was designed for!

Communications are available with :

Licensed Radio●

Spread Spectrum Radio●

LEO (Low Earth Orbit Satellite Radio)●

Cellular Radio●

Dial-Up Land Line Modems●

Cellular Telephone●

CDPD Radio●

and more........●

Page 66: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Compressor Monitoring Package ...Just Specify your Application...

From Onshore to Offshore environments, Just askfor a custom program or do it yourself with ourspreadsheet style programming tool.Communications are easily configured with a frontentry universal mounting panel. The field I/O wiringcan be left untouched in the event of a com. problemor upgrade to a different system.

Solar Systems are available from 10 to 120 watts ofcharging power. All hardware needed for a completeinstallation is included.

 

 

Dual 100 AH Battery Enclosure for AdverseEnvironments

Series 3405

Ultrasonic Meter Interface

This Ultrasonic Interface Series includes the different types of ultrasonic measurementconfigurations:

3401 - Single Path Bi-directional Ultrasonic Application

3402 - Two Path Bi-directional Ultrasonic Application

3404 - Four Path Bi-directional Ultrasonic Application

The Series 3405 supports a local parallel interface port to perform initial unit configuration,periodic transmitter calibration, flow parameter changes, alarm settings and historical dataretrieval. Once configured, ultrasonic meter configuration, alarms, diagnostics and flowparameters may be retrieved from a host or local computer. All instantaneous and historicaldata items are available for retrieval by the host or local computer. Two RS-232 ports areavailable; one port connects to the ultrasonic meter, while the other can be used for remotedata acquisition or to another RTU/flow computer device. An I/O card provides optical isolatedfield wiring termination for the frequency and status outputs. Eight analog, four digital and twoRTD inputs are available for user defined functions. Additional I/O cards can be added for moreRTU type functions or to provide "mirror" signals to another flow computer/data acquisitionsystem.

Page 67: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

An Optional Graphics LCD display, viewable through a window on the front of the unit, provideslocal display of instantaneous and previous day data.

A Class I, Division 1 hazardous location approval for the Series 3405 is available (StandardConfiguration is for General Purpose Use Only). This U.L./C SA listing includes both systemsand entity approvals. Remote communications (radio, dial-up, cellular, etc.) with a Series 3405in a Division 1 area is accomplished through the Modem interface Module which mounts in anadjacent non-hazardous area and provides intrinsically safe power and an optically isolatedRS-232 interface to the Series 3405.

The Series 3405 Provides an RS-232 Modbus link to the Ultrasonic which polls specific dataregisters for giving a frequency output to other end devices. The frequency output comes fromthe TYPE 2 IOU card. The frequency is scaled for a maximum of one KHZ with the voltageoutput being an open collector opto isolated type (max.12mA at 24VDC). The 3405 polls theaccumulated volume registers as they become available from the Ultrasonic meter( 4 to 5seconds). This volume block is broken up as to provide a continuos frequency stream based ona maximum output of 1 Khz. This method is basically a "frequency continuous volume totalizer".Each pulse represents a single uncorrected cubic foot of volume. The capability for applying anoutput "K factor" will multiply this value to the current output frequency. Volumes can becalculated using AGA7/AGA8 1992 when connected to a pressure and temperature transmitter.

Series 3000

The Series 3000 flow computer is designed to measure and control the flow of natural gas orliquids. Thismeasurement can be from a PD, turbine, or an orifice meter. Current applicationscan provide single, dual, and triple meter tube configurations. Any 3000 RTU's can beexpanded from a single IOU card (I/O termination's)tomultiple cards for much largerinstallations. The basic single IOU card configuration has two RS-232 serial portsand oneparallel port. These communication ports can be configured to bring in data from a gaschromatograph, remote data retrieval, and local operator (technician) use. The Series 3000 iscertified by U.L. for use in a Class I, Division 1, Group D hazardous location. Data retrieval,when configured for remote access, can be accomplished by cellular radio, UHF & VHF radio,and Dial-Up land line modems. The 3000 has extremely low power requirements and canoperate using solar or AC/DC charging systems. When sizing a communication power system,the 3000 can be connected to the 12VDC battery with only a 40mA drain. This techniquereduces initial cost, eliminates a second power system, and simplifies installation andmaintenance. Daniel has Series 3000 systems installed from Michigan to Argentina. Most ofthese systems are solar powered with radio communications.

Standard Configuration

NEMA-4X Painted Aluminum Enclosure for 2 inch Pole Mount●

(1) PARALLEL & (2) RS-232C Communication Ports●

512 KB Non-volatile RAM & 512 KB Program Memory●

Page 68: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

One TYPE 2 I/O Card●

8 Analog Inputs (1-5VDC)●

4 Status Inputs●

2 RTD Inputs●

2 Frequency Inputs (0-10Khz)●

2 Analog Outputs (1-5VDC)●

2 Frequency Outputs (DC to 1Khz)●

2 Status Outputs ( Open Collector )●

Class I, Division 1 & 2, Group D -- U.L. & CSA Entity Approvals●

Specifications

MAIN CPU CARD

Processor: 12 MHZ 80C186 (3 VOLT INTEL)Non-Volatile RAM: 500K expandable to 8 Megabytes (Battery Backed)Program Memory: 500K expandable to 2 Megabytes (FLASH)Back Up Battery: Replaceable Lithium (1Year Continuous/10 Year Shelf)I/O Bus Architecture: I Square C BusCommunication Ports: Modbus ASCII or RTU Protocol1- Parallel Port for Local Access1- Remote(Host) RS-232 Serial Port; 19.2K bd Supported1- Modbus Master RS-232 Serial Port; 9600 bd Supported

TYPE 2 I/O CARD

Inputs - Analog:

8 High Level 1 to 5 Vdc ( Transformer Isolated)●

2 RTD inputs; 3 wire 500 Platinum Element●

16 Bit A/D Accuracy●

Inputs - Digital:

4 High Level Status or Contact Closure Type Inputs (Optical Isolated)●

(IE., Compressor Oil Pressure Alarm)●

Inputs - Frequency:

2 High or Low Level (PreAmp Daughter Board) Type; DC to 10 Khz●

Outputs - Analog:

2 High Level 1 to 5 Vdc●

Page 69: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Outputs - Digital:

4 Open Collector (Opto-Isolated)●

Frequency proportional to uncorrected Rate/Volume or●

User Definable; Maximum Frequency Update is 1 Khz

12 mA @ 35 V●

Transient and Surge Suppression:

Meets or Exceeds IEC 801-2●

Meets or Exceeds ANSI/IEEE C37.90.1●

Input Power:

@ 6 to 12 VDC●

@ 24 VDC --SAFE AREA USE ONLY --●

Power ( Typical):

65 mA @ 6 VDC

41 mA @ 12 VDC

25 mA @ 24 VDC

Optional

Graphics Display:

120 x 64 pixel

8 lines x 20 Characters

Size; 6"W x 3.5"H

Environmental:

-22 to +158 deg.F (-30 to +70 deg. C)●

5 to 95 % Relative Humidity; Non-Condensing●

Mechanical:

NEMA 4X Enclosure●

12"W x 12"H x 9.5"D●

13 Gauge Aluminum with Powder Coat Paint●

Stainless Steel Latches with Lock Hasp●

less than 5 lbs empty●

Hazardous Classifications:

Class 1 Division 1 Groups C & D, CSA & U.L., ENTITY●

Page 70: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Class 1 Division 2 Groups C & D, CSA & U.L.●

Power Supply Options:

* 6 Vdc Gell Cell Rechargeable, Solar 10 watt Division 1

* 12 Vdc Gell Cell Rechargeable, Solar 24 watt Division 2

* 12 Vdc/110 Vac Float Charging System, Non-Hazardous

Communications Options:

Low Power 212A Modem; 2400 bd. Dial - Up Communications; Division 2

for Installation inside the Standard Enclosure

Optional TYPE 1 I/O CARD

Inputs - Analog:

2 High Level 1 to 5 Vdc ( Transformer Isolated)●

1 RTD inputs; 3 wire 500 Platinum Element●

16 Bit A/D Accuracy●

1 Smart P/DP Transmitter Interface●

Inputs - Digital:

4 High Level Status or Contact Closure Type Inputs (Optical Isolated)●

(IE., Valve Open/Close Status)

Outputs - Analog:

1High Level 1 to 5 Vdc●

Outputs - Digital:

4 Open Collector (Opto-Isolated)●

Frequency proportional to Rate/Volume or●

User Definable; Maximum Frequency Update is 1 Khz

12 mA @ 35 V●

Digital Flow Measurement

Page 71: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Daniel Measurement and Control

Houston, Texas, Telephone: (713) 467-6000, Fax: (713) 827-3880

Larbert, Scotland, Telephone: +44-1324-556111, Fax: +44-1324-562290

OFFICES AND REPRESENTATIVES WORLDWIDE

www.danielind.com

All specifications subject to change without notice as part of a continuing program of productimprovement

 

Page 72: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Solar Flow Computers

Overview

Specifications

Reports

2480 Overview

2480 Specs

Go directly to the Product Discussion Forum for this product

Page 73: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Product Overview

SOLARFLOW PLUSTHE BATTERY POWERED RTU

Solarflow-Plus: A Battery Powered RTU (Remote Terminal Unit) With Flexible Calculation and AdvancedCommunication Capabilities

When power is unavailable or unreliable, consider a Solarflow-Plus RTU for your flow-measurement system.Replace mechanical circular charts with this versatile microprocessor. Eliminate maintenance costs andcalibration problems of mechanical charts. Speed the collection of more accurate data for faster operationalcontrol and billing with its flexible capability for interfacing via telephone, cellular telephone, radio, satellite, fiberoptics, or other communications media.

Built for typical outdoor, remote installations and environmentally tested at the factory, Solarflow-Plus unitsprovide maximum measurement and communications versatility in a cost-effective package. We invite you toexamine the additional details in the rest of this brochure about the battery powered RTU for your remote flowmeasurement and data communication needs.

COMMUNICATIONS

Solarflow-Plus RTU capabilities match any existing or new communication links. Including speech!

Auto-dial alarm callout activates speech synthesizing circuits for verbal reports to the operator via telephone,digitally to a remote printer, or to a central computer. The RTU can also be queried directly from a touch-tonetelephone keypad to produce "verbal" response for immediate and easy-to-understand third-party reports.Third-party reports can also be displayed by a "dumb" terminal or printer.

Our Daniel specialists can tailor communication protocols to integrate with your existing or planned SCADAsystems. Or we can help you design completely new networks. Our optional protocol is Gould Modbus; otherscan be quickly implemented. The Solarflow-Plus RTU can be integrated into telephone, cellular telephone,radio, satellite, or fiber-optics communication systems.

Longitudinal Redundancy Check (LRC-16) techniques assure data integrity to or from a Solarflow-Plus unit.

INPUTS

One of the important benefits you can enjoy with a Solarflow-Plus system is measurement flexibility to meetyour current and future needs. Standard input configurations include:

stacked or single DP for orifice●

parallel orifice●

triple-run single DP●

parallel or single turbine or PD meters●

Page 74: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

with temperature, pressure and specific gravity correction if desired. Nine status inputs are available formonitoring on-site conditions.

CALCULATIONS/OUTPUTS

AGA 7, AGA 3 and full NX19 calculations are made on-site based on transmitter samples every 1/2 second.Each factor is calculated directly from the AGA equations from every ten seconds to once a minute, dependingon the application. These calculations are at a much faster rate than the less accurate hourly updates currentlyavailable.

The Solarflow-Plus memory stores up to 35 days of hourly data on volume, differential pressure or meterpulses, flowing temperature and alarms. Parameters logged are operator programmable. Solarflow-Plus unitscan produce a new log every time a critical parameter changes. For example, if an orifice plate is changed,measurements immediately after the change will be accurate rather than having to wait for the next loggingperiod before the new plate diameter is used in calculations.

Time, pressure and temperature indices, formerly derived from charts, can be produced thus providing asmooth transition from charts to electronic flow measurement. Solarflow-Plus systems offer complete audittrails plus a wide range of data logging intervals including 5, 15, or 30 minutes and 1, 4, and 24 hours as wellas monthly.

All data can be quickly, accurately, and reliably transmitted to your central computer via virtually any fieldcommunication technique. Similarly, parameter logging intervals and alarms/reports configurations can bequickly downloaded from a host to the Solarflow-Plus RTU.

Data transmission is most rapid with a direct link from filed to office. However, you can let a Hand-Held DataTerminal (HHDT) "dump" to a printer or host computer direct or via telephone modem when this format isadvantageous for you.

Each HHDT can collect up to 35 days of hourly data from up to 7 Solarflow-Plus units, up to 30 with expandedHHDT memory. Even more units can be downloaded if less than 35 days information is required or timeintervals are longer than hourly.

Page 75: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

SpecificationsSOLARFLOW PLUS

OPERATING TEMPERATURES-20º to 160ºF

SAFETY CLASSIFICATIONClass I, Groups C & D, Division 1Intrinsically safe--solar chargedGeneral purpose--115 V charged

WEIGHT100 lbs.

INPUTS8 analog (1-5 DC)9 status2 pulse (turbine/PD meter)

OUTPUTS9 control, two of which activate relays (10 VA Form A for pulsing samplers)

SERIAL OUTPUTSHand-Held Data Terminal for local data collections, set-up, and calibrationRS- 232C for direct, radio, or satellite link to a host

TELEPHONE OUTPUTDirect wired with Daniel interface module

PROTOCOLGould ModbusOther protocols available

INTEGRAL TRANSIENT/SURGE PROTECTIONAll inputs and outputs protected

ENVIRONMENTDesigned and built for outdoor use.Each unit dynamically tested in our environmental chambers with temperature cycled between -20º and+160ºF.

HAND-HELD DATA TERMINAL

OPERATING TEMPERATURES

Page 76: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

-20º to +160º

WEIGHT1 lb.

SAFETY CLASSIFICATIONClass 1, Group D, Division 1Intrinsically safe

INPUTSData received from Solarflow-Plus Operator inputs to set up, calibrate, collect, and print data locally or transmitto a central computer via modem

OUTPUTSRS 232C to modem for telephone, or to printer for local report

CAPACITYUp to 35 days or hourly records from 7 sites, up to 30 sites with expanded memory--even more if fewer daysand/or longer intervals

Communication flexibility complements calculation capability for Solarflow-Plus systems. A Hand-Held DataTerminal allows local data collection. Telephone and radio interfaces allow bidirectional communication. Or usethe latest cellular, fiber optics, and satellite communication techniques. Enjoy maximum uptime, data integrity,message security--and complete downloading flexibility.

Our staff of communications and software engineers is ready to work with you to select the bestcommunications systems for your needs--whether interfacing with existing systems or designing from "scratch."

When reliable data transmission counts, count on Daniel.

Page 77: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Reports

CURRENT MEASUREMENT

This report is operator programmable for any combination of up to ten fixed-parameters or line processvariables. Alarms currently present will be given first. Reports are also available via synthesized speech over aphone line for operator and/or third-party monitoring. If programmed limits are exceeded, an auto-dial modemcalls designated telephone numbers and the Solarflow-Plus speech synthesizer provides verbal alarmmessages along with the current measurement data.

AUDIT TRAIL

An Event Log provides the date/time of any alarm, log-on, or parameter change--plate size, for example.Log-on includes operator password to identify who made the change. Values before and after the change arealso provided. The Event Log gives you a complete audit trail.

AVERAGE DATA FOR TIME INTERVAL

A Data Log Lists provides you with date, time, average pressure, differential pressure, flow rate, total volumesand flowing temperatures, and other programmable parameters. A Solarflow-Plus system can log data every 5,15, or 30 minutes, every 1, 4, or 24 hours, or monthly. You select the interval best suited to your needs witheach Solarflow-Plus unit.

Page 78: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Product Overview

SINGLE-TUBE SOLARFLOW-PLUS RTUMODEL 2480

SOLARFLOW-PLUS RTU's are the most widelyused, proven, battery-operated family of RTU/FlowComputers in the field worldwide. The Model 2480 isdesigned for single-tube orifice or turbine/PD meterswith mechanical instrument drives and pulsers. Itperforms custody transfer flow measurementaccording to the latest AGA 3 and AGA 7requirements and performs full NX19 calculations.The Model 2480 is packaged in the new "easyclamp"design to simplify installation. In summary, the Model2480 provides complete flow measurement and datacalculation/storage for single tube gas applications.AGA 3 and AGA 7/NX19 calculations are available inboth imperial and metric units. Also, the model 2481Pis available for premium billing applications. The2481P provides for operator entry of asupercompressibility matrix.

Page 79: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Specifications

FIVE ANALOG INPUTS

One dedicated input for a Daniel-supplied 500 ohm RTD for temperature measurement.1. One dedicated input for a Daniel Model 224-series static-pressure transducer.2. One dedicated input to monitor the battery's state-of-charge.3. One auxiliary 1-5 VDC input.4. One 1-5 VDC input for low-power differential pressure transmitter.5.

(A/D conversion resolution 12 bits " 1 bit, temperature coefficient 0.005% per degree F.)

STATIC-PRESSURE TRANSDUCER INPUT:

Maximum error--including combined effects of linearity, repeatability, and hysteresis--less than or equalto "0.25% of span.

A/D conversional resolution 12 bits " 1 bit.●

Temperature error including span and zero errors to be less than or equal to "1% of span per 100ºF.●

TEMPERATURE INPUT:

Designed to operate with a 500 ohm platinum RTD with a designed range of 0º to 150ºF.●

Maximum error--including combined effects of linearity, repeatability, and hysteresis--less than or equalto "0.25% of span.

A/D conversion resolution 12 bits " 1 bit.●

Temperature coefficient 0.007% per degree F.●

PULSE INPUTS:

To be used with a PD meter pulser or turbine with a mechanical instrument drive and pulser with dry,isolated contact closure. Maximum frequency 50 Hz.

STATUS INPUTS:

Four for sensing external signals. (Field input via voltage-free dry contact closure to common.)●

Max external loop impedance 500 ohms.●

Status inputs transient and RF protected.●

CONTROL OUTPUTS:

Four.●

Output low 4 mA.●

Page 80: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Output high 1mA.●

COMMUNICATIONS:

RS 232 serial port for Hand Held Data Terminal. Baud rate 1200. Full duplex. RTS/CTS handshaking.●

ENVIRONMENT

NEMA 4X enclosure.●

Relative humidity 0-95% noncondensing.●

Temperature: -20 to 160ºF operational, -40 to 160ºF storage.●

RFI/EMI:

Greater than 10 volts/meter, 1 KHz-1GHz tested using MIL STD 461 (RS03 method).●

MECHANICAL:

RTU: 12"H x 6"D x 12"W--add 2 1/4" W for mounting bracket. Weight approximately 5 lbs.●

Solar Panel: 16 1/2"W x 10 3/4"H x 5"D. Weight approximately 15 lbs.●

Page 81: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

2500 Turbo Flow Computer Brochure

Features and Advantages

Overview

Hardware

Input/Output Capabilities

Software

Specifications

Enclosures and Other Options

Page 82: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Features & Advantages486/100Mhz/4 Meg...Full 32 bit microprocessors●

PC/104 (Compact ISA) expandable Bus..... Upgrade path for future microprocessors●

Future plug-in module support.....ethernet, fax modem cards●

Solid State Disk Technology, not EPROMs●

Compatible with existing RTU enclosures●

Save on labor costs●

Use existing transmitters and wiring●

Minimal downtime for upgrading●

Operational familiarity●

No new panel cutouts●

Future processor, I/O, memory, communication upgrade path●

Faster application cycle times●

Higher serial port baud rates●

Existing application compatibility●

16 bit analog conversions using software filtering for smoother updates●

 

Page 83: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

OverviewThe Daniel 2500 Turbo Flow Computer Upgrade Can Turbocharge Your Existing 2500 for PerformanceSecond to None.

Legendary Performance- With thousands in use the world over, the Daniel 2500 Flow Computer is thereliable, accurate workhorse of the flow measurement industry. 

And now, a simple retrofit or upgrade is all it takes to turn your existing 2500's into the Daniel TURBO 2500high performance tools you'll need to help you better meet tomorrow's need for power, speed, versatility andease of use.

Upgrading is easy as 1,2,3-

   1) Replace the existing 2500 CPU with a new, PC-based TURBO Card Set and its built-in high-performance Quad Power Supply.

    2) Compile your existing applications with ease via our new Config 25 program and download them to thenew TURBO computer.

    3) Go back on-line with turbocharged speed and PC convenience.

Expandable PC/104 Architecture- The 2500 TURBO Flow Computer incorporates a full-function PC/104 card,a compact PC-standard format for implementing the PC ISA bus.  This versatile, flexible architectureaccommodates plug-in modules to help maximize upgrade paths for future applications.  Best of all, this simpleupgrade swaps proprietary microprocessor designs for PC convenience to make the 2500 TURBO even easierto adapt to virtually any flow measurement programming challenge.

Upgrade Path- The 2500 TURBO's CPU board houses the PC/104 microprocessor card.  This card alsomaintains the I/O circuitry for outstanding "plug-in" compatibility with existing wiring configurations.

No Need to Change Application Programs- Whether upgrading an existing 2500 or installing a new 2500TURBO, all of your application programs can be used.

A new Config 25 program helps you recompile or create a new application and this application is easilydownloaded into the TURBO card set.

Beefed-Up Power Supply-  The new power supply uses Industry Standard modules that provide a higherpower output and a wide (18 to 36Vdc) input voltage range.

Measurement and Control- Process measurement and flow control require fast cycle timing.  The 2500TURBO can handle the toughest metering requirements.

The 2500 TURBO can provide these calculation methods, and more: AGA3 (API 12530), ISO  5167, AGA 5,AGA 7, AGA 8,(Gross and Detail methods). API 1101, API 2534 and API 2540. Other calculation methods areavailable.

Applications

Single and Multiple Tube Metering for Gas, Liquids and Steam●

Page 84: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Gas Orifice Metering, Gas Ultrasonic Metering●

Gas & Liquid Turbine Metering●

Venturi, PD and Nozzles●

Page 85: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

HardwareThere are two types of 2500 TURBO Series computers: The basic Model 2521 is configured to handle themajority of instrument applications.  When additional measurement points are required, an internal expansionboard is added to the Model 2521 to make a Model 2522.  The front panel contains three status LED's, asixteen key keypad, and a two line backlit LCD screen.  The three status lights are used to give quickindication of the unit's operational status.

Page 86: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Input/Output CapabilitiesThe basic 2500 TURBO Series has two communications ports.  One is an RS-232C compatible port.  The otheris factory configured as an RS-232C, RS-422 or RS-485 port.  The expansion board adds a second RS-232Cserial port.  These ports may be used for printer output, networking, or host computer communications viamodem, direct wire, radio, or satellite link.

I/O Capabilities By Model

2521 2522  

6 18 analog inputs (12 bit resolution)

2 6 frequency inputs for turbine meters (0-4000 Hz)

1 2 frequency inputs for densitometers (0-10,000 Hz)

6 24 contact closure status inputs

6 24 transistor switch outputs(latched or pulsed, 100ma @ 30 VDC)

2 4 analog outputs 4-20mA (maximum 800 ohm load)

1 2 RS-232C serial ports with modem controls

1 1 RS-232C or RS-422/485 serial port

1 1 alarm contact closure (form C relay)

1 1 prover switch

The 2500 TURBO has these configurations along with the expansion capabilities of the PC/104bus.

Page 87: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

SoftwareMODBUS ASCII or MODBUS RTU Protocol-

The areas that can be configured are:

    Hardware inputs and outputs1.     Alarm messages2.    Operator entry messages3.     Report formats4.     Tables of data used by 25005.     Calculations to be performed6.     Communications7.

Simple Configuration- Configuration is made simple by the use of menu driven screens.  The general menuallows selection of the major task, and subsequent screens guide the user through the configuration procedure.

Configurations for standard calculations, such as AGA3/API 2530, ISO 5167, AGA 5, AGA 7, AGA 8, API 1101,API 2534, Meter Proving, Steam and CO2Flow are available from Daniel.  But the flexibility of Config 25 allowsthe user to modify standard calculations to meet special applications or to configure special calculations, suchas energy balance.

The 2500 TURBO Microcomputer uses two set of software in its real time multi-tasking operating system. BASE25 is installed in FLASHRAM and performs the basic calculations required for flow measurement.  Config25 provides a means to tailor the operation of the unit to perform specific functions.  The configuration is doneon a PC compatible computer and downloaded to RAM in the Series 2500.  Model 2521 and 2522 have up to 4megabytes of memory.

BASE25 performs arithmetic functions and also contains the table and equations used in the AGA and APIcalculations.  Config 25 is a menu-driven program that enables the user to configure the Series 2500 for thedesired application.

 

 

 

Page 88: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

2500 TURBO SpecificationsMain CPU Card

Microprocessor Options:

486 DX4, 100 Mhz, 32 Bit

V20, 4.77Mhz, 16 Bit (non-turbo)

Solid State Disk:

486 Card Set- 4 Megabytes

RAM:

486 Card Set- 4 Megabytes

Back Up Battery:

Replacement Lithium (1 Year Continuous/10 Year Shelf)

I/O Bus Architecture:

PC/104 Compact ISA

Input/Output

Analog Inputs:

    Up to 18 channels...

Current/Voltage (4-20mA or 1-5 Vdc)

Input impedance 250 Ohms ± 0.05% for current loop

Resolution 12 bits (16 bit Internal Conversation)

Frequency/Pulse Inputs:

    Up to 8 channels...

6 Turbine inputs 0-4,000 Hz range

2 Densitometer inputs 0-10, 000 Hz

10vPP nominal

Status Inputs:

    Up to 24 digital inputs...

Page 89: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Input signal levels 14.8 Volt nominal pull up voltage

Field input via voltage free "dry contact" closures to common

Input voltage protection circuit

1 Prover Input-Can use uni-directional, bi-directional or double chronometry

Analog Outputs:

    Up to 4 analogs...

4-20mA

Maximum load 800 Ohms

12 bit resolution

On-off, pulsed and individual alarms...up to 24 provided   via open collector transistors

Communications:

Three Communication Ports-provides flexibility to user allowing RS-232C or RS-422/485

Self Diagnostics

The 2500 incorporates a set of self diagnostics

Precision Analog Reference- This feature allows the 2500 to automatically re-calibrate itself before eachcalculation cycle.

Built-in Check Sum- Upon power up/utilization the 2500 memory is interrogated and validated both in RAMand ROM and their associated hardware- instantaneously.

Watchdog Timer- Fail-safe alarm on any malfunction

Electrical

Operating Voltage:

20-28 V.C. or 115/230 VAC, 47-63 Hz

Power Consumption:

50 watts maximum including power for all transmitters

Environmental

NEMA 13 box with integral front panel- operational temperature is 0 degrees F to 140 degrees F

NEMA 4X box without front panel- -20 degrees F to 160 degrees F

Humidity

0-95% non-condensing

Approvals

CSA, CCA; pending

Page 90: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

 

Page 91: Standard Capacity Gas Turbine Meter Brochure - Emerson Daniel... · Standard Capacity Gas Turbine Meter Brochure ... A spin test of the gas turbine meter rotor does not ... Daniel

Model 2500 TURBO  Enclosures and Other Options-

Retrofit kit●

Standard rack mount●

NEMA 13 painted stell 20" x 20"●

NEMA 12 stainless steel 24" x 30"●

NEMA 4X stainless steel 24" x 30"●

Canada box●

Power Supply Options:

110 vac supply●

24VDC input●