CHECK LIST FOR DETECTING AIR INGRESS IN CONDENSER
Sl. No.
Description Location Remarks
1. Vacuum breaker Valve 17 M2. HPT glands 17 M3. LP Heater-2 emergency drip line ( LCR-0757B-HD4-
022)0 M
4. LP Heater-3 emergency drip line 0 M5. CEP – A/B/C glands (-Ve)M6. CEP – A/B/C suction strainers (-Ve)M7. CEP – A/B/C suction line drains (-Ve)M8. Condenser level transmitters. 0 M9. Condenser level Switches. 0 M10. TDBFP-A exhaust valve 8.5 M11. TDBFP-B exhaust valve 8.5 M12. TDBFP-A gland 17 M13. TDBFP-B gland 17 M14. LPT Diaphragm 17 M15. TDBFP-A Diaphragm 17 M16. TDBFP-B Diaphragm 17 M17. Hotwell drain (-Ve)M18. LPT Manholes ( both side ) 17 M19. CEP recirculation lines-A,B,C valve glands. 2 M20. LPH-1 normal drip to condenser valves. 2 M21. CEP suction and discharge line flanges (-Ve)M22. Vaccum pump-1,2 suction line manual and motorised
valve glands and flanges.0 M& 8.5M
23. LPH-2 shell side vent line flange 8.5 M24. LPH-3 shell side vent line flange 8.5 M25. LPH-1 Emergency drip to condenser( LCV-0700) 0 M26. Deaerator to condenser( CO-151 )line valve 0 M27. TFT-1 & TFT-2 and the drains headers connected to
the tanks.28. Condenser man hole at 8.5 mtr near LPBP valve.