SS5 Linear / Rotary
Output position transmitter (4 - 20 mA)2 x alarm limit or micro switch (SPDT)Explosion proof type (IECEx / ATEX / KC Ex ia IIC T6/T5)HART communicationProfibus communicationFieldbus Foundation communication (in progress)
Perfect combination with reliable fail freeze function and smart performance with innovative durable coil drive
“Fail Freeze” function to help the valve stay at the last position on the electrical power supply or the pneumatic supply air by accidentEasy and quick auto-calibration Detecting RA (reverse acting) or DA (direct acting) automatically regardless of wrong air connectionsAvailable to use for single or double acting without any special adjustments Compact design allowing to be installed on small actuatorsProviding error messages against performance failuresPossible to test the actuator with any fixed signal under a test modeProgrammable characteristic curve with 17 pointsWide operating temperature range -30 ~ +80℃Improved control of high-friction globe and ball valves by eliminating an overshoot and a huntingLow air consumptionProviding a mounting bracket to meet IEC 60534-6-1 for linear valvesSupporting a NAMUR mounting pattern VDI/VDE 3845 (IEC 60534-6-2)and providing a multi-size mounting bracket for rotary valves
- SS5R (Rotary Type)
- SS5L (Linear Type)
B19
Input signal
Alarm limits 1, 2
Output signal
LR
I
K
W
ABCD
FN
012
NO
LSMQ
NHPF
345
NLR
01
::
:
:
:
::::
::
:::
Actuator Operation :
Protection Class :
Feedback Lever : - Linear Type
- Rotary Type
Pressure Gauge Block :
SS5 Linear / Rotary
SS5 ActuatorOperation
ProtectionClass
FeedbackLever
Pressure Gauges
Position Feedback
Communi-cation
ConnectionThreads
MountingBracket
Feedback PinGuide Lever
Set
B21
1 : Air supply2 : OUT 13 : OUT 24 : Display LCD5 : Up key6 : Mode key7 : Enter key8 : Down key
9 : Input signal (+, -)10 : Frame ground11 : Output signal (+, -)12 : Alarm limit 113 : Alarm limit 214 : Electrical connections15 : Ground16 : Feedback lever
SS5 Front Cover Removed
Micro switches 1, 2
Linear typeRotary type
Intrinsically safe (IECEx Ex ia IIC T6/T5, ATEX Ex ia IIC T/6T5)Intrinsically safe (KC Ex ia IIC T6/T5)Weatherproof to IP66
Stroke (5 ~ 30mm)Stroke (5 ~ 65mm)Stroke (5 ~ 130mm)Stroke (80 ~ 200mm)
Fork lever Namur shaft (direct mounting)
Not mounted6 bar (90 psi) 10 bar (150 psi)
Position Feedback :
Communication :
Connection Threads :(pneumatic - electrical)
Mounting Bracket :
Feedback Pin GuideLever Set :(only for linear type SS5L)
NonePosition transmitter(4 ~ 20mA output signal)2 x alarm limit2 x micro switch (SPDT)O+LO+S
NoneHARTProfibusFieldbus (in progress)
Rc 1/4 – G1/2 (standard)NPT 1/4 – NPT 1/2Rc 1/4 – M20 x 1.5
NoneIEC 60534-6-1 (for SS5L)VDI/VDE 3845 /IEC 60534-6-2 (for SS5R)
Not includedIncluded
::
::::
::::
:::
:::
::