Squeezing with long (100 m scale) filter cavities

24
Squeezing with long (100 m scale) filter cavities 23-28 May 2016, Isola d’ Elba Eleonora Capocasa, Matteo Barsuglia, Raffaele Flaminio APC - Université Paris Diderot

Transcript of Squeezing with long (100 m scale) filter cavities

Page 1: Squeezing with long (100 m scale) filter cavities

Squeezing with long (100 m scale) filter cavities

23-28 May 2016, Isola d’ Elba

Eleonora Capocasa, Matteo Barsuglia, Raffaele Flaminio

APC - Université Paris Diderot

Page 2: Squeezing with long (100 m scale) filter cavities

• Why using long filter cavities in enhanced interferometers ?

• What performances are required?

• What is the state of the art?

• Which are the experimental challenges and the improvements needed to achieve optimal performances?

2

Page 3: Squeezing with long (100 m scale) filter cavities

Why using filter cavities in enhanced interferometer?

3

• Filter cavities impress a frequency dependent rotation on the squeezing ellipse

• Reduced noise quadrature always aligned with the signal

• First implementation: only one filter cavity (broadband ITF)

Page 4: Squeezing with long (100 m scale) filter cavities

4

Why using (long) filter cavities in enhanced interferometer?

PHY. REV. D 90, 062006 (2014) Decoherence and degradation of squeezed states in quantum filter cavities

P. Kwee et al.

• First implementation of frequency dependent squeezing in Advanced LIGO: 16 m filter cavity with losses target 1 ppm/m

• Squeezing is deteriorated by cavity losses at low frequency but thermal noise is relevant in that region (little room for improvements)

• Goal : avoid to spoil sensitivity at low frequency

Advanced LIGO sensitivity, 16 m filter cavity with loss of 1 ppm/m

Page 5: Squeezing with long (100 m scale) filter cavities

5

Why using long filter cavities in enhanced interferometer?

KAGRA sensitivity, 300 m filter cavity with loss of 0.25 ppm/m

• Effect of the cavity losses is reduced since the cavity is longer • Thermal noise is lower due to cryogenic operation • Sensitivity can be improved also at low frequency

Page 6: Squeezing with long (100 m scale) filter cavities

6

• The use of a long filter cavity will improve of 20% the BNS range with respect to a short filter cavity in an upgrade version of Advanced LIGO

Why using long filter cavities in enhanced interferometer?

Page 7: Squeezing with long (100 m scale) filter cavities

• The target frequency ΩSQL at which the squeezing rotation should take place is about 2π x 70 Hz (depending on the power)

• The storage time need to achieve it is more than 2.5 ms (among the highest storage time ever achieved)

What performances do we need for achieving an optimal rotation?

The realistic target: 6 dB of measured squeezing at high frequency

7

Page 8: Squeezing with long (100 m scale) filter cavities

What has been done so far?

• Rotation of the squeezing angle already demonstrated

@ MHz

8

Page 9: Squeezing with long (100 m scale) filter cavities

What has been done so far?

• Rotation of the squeezing angle already demonstrated

@ KHz

9

Page 10: Squeezing with long (100 m scale) filter cavities

Ongoing activities

• 16 m filter cavity and full scale prototype of in-vacuum squeezed source for aLIGO at MIT in the LASTI facility. Assembly is starting now.

• 50 m filter cavity prototype (CALVA) in Orsay. Optical design ongoing. 10

credit: Lisa Barsotti

Page 11: Squeezing with long (100 m scale) filter cavities

Ongoing activities

• 300 m filter cavity prototype is being installed at NAOJ in TAMA infrastructure

11

Page 12: Squeezing with long (100 m scale) filter cavities

Planning

• End 2016 filter cavity characterization and losses measurements

• 2017 frequency independent squeezing production

• 2018 frequency dependent squeezing measurement

12

Page 13: Squeezing with long (100 m scale) filter cavities

Experimental issues with long filter cavities

13

• Relax the requirement on the finesse

• Reduce the impact of cavity losses

�fc

=1

⌧storage

=⇡c

2Lfc

F ' 2⇡ · 50Hz

L = 16m ! F ' 90000 L = 300m ! F ' 5000

• More complex infrastructure

• Cost

PROS

CONS

Page 14: Squeezing with long (100 m scale) filter cavities

Effect of the filter cavity losses

14

• Losses are more influent at low frequency where the squeezing experiences the rotation

• The cavity performance depends on the loss per unit length

�fc = ct2in + ⇤2

rt

4Lfc

Page 15: Squeezing with long (100 m scale) filter cavities

How to minimise the effect of the losses?

15

Improve the mirrors quality (which are the limits?)

Increasing cavity length

The loss per unit length are observed to decrease with cavity length

Page 16: Squeezing with long (100 m scale) filter cavities

Intracavity losses mechanisms

16

The main losses mechanism is the scattering from the mirrors originated by:

• flatness (up to 1000 m-1) • roughness • point defects

VirgoAdVirgo

We can neglect cavity losses (<1 ppm) caused by

• absorption • end mirror transmission • clippling losses (in case of perfect spherical mirrors)

Page 17: Squeezing with long (100 m scale) filter cavities

Simulated losses for different mirror qualities

0.05 0.01

1.23 0.81

1.36 0.53

0.27 0.18

diameter[m]

RMS [nm]

RMS [nm]

42 ppm RMS [nm]

6 ppm

82 ppm

17

Simulation performed for a 300 m filter cavity using Virgo and AdVirgo mirror maps

10 ppm to be added from roughness and point defects contribution

Page 18: Squeezing with long (100 m scale) filter cavities

Estimated losses for the 300 m filter cavity

18

Virgo mirror quality => 70 ppm + 10 ppm = 80 ppm => 0.25 ppm/m

AdVirgo mirror quality => 6 ppm + 10 ppm = 16 ppm => 0.05 ppm/m

Page 19: Squeezing with long (100 m scale) filter cavities

Squeezing degradation mechanisms

• Filter cavity losses

• Injection/readout losses

• Mode mismatch

• Frequency-dependent phase noise

• Frequency-independent phase noise

19

• Some degradation mechanisms that can be reduced by increasing cavity length

Page 20: Squeezing with long (100 m scale) filter cavities

Squeezing degradation budget

for a 300 m filter cavity with losses of 80 ppm (0.25 ppm/m)

20

injection losses 5 %

readout losses 5 %

mismatch squeezer-filter

cavity2 %

mismatch squeezer-

local oscillator5 %

δL (rms) 0.3 pm

Page 21: Squeezing with long (100 m scale) filter cavities

Squeezing degradation budget

cavity losses in a 16 m cavity (1ppm/m)

21

Page 22: Squeezing with long (100 m scale) filter cavities

Squeezing degradation budget

22

cavity losses with AdVirgo mirror quality (0.05 ppm/m)

Page 23: Squeezing with long (100 m scale) filter cavities

Effect of the losses inside the interferometer

23

Arm cavity losses

SEC losses

• The SR mirror increase the interferometer bandwidth suppressing the effects of arm cavity losses

• SEC losses has a greater impact on squeezing degradation

Page 24: Squeezing with long (100 m scale) filter cavities

Conclusions

24

• The use of long filter cavity will improve the sensitivity of enhanced detectors in the whole bandwidth, in the scenario where quantum noise is dominating also at low frequencies

• Using >100 m filter cavity and best mirror quality available the effects of cavity losses become negligible with respect to the other loss sources

• Further improvement in the squeezing level will require to improve the mode matching and injection/readout losses

• Longer term future: long filter cavity (km scale) necessary for ellipse rotation at few Hz as planned in ET design