SQ-1 ROOF TRUSS

WEG-IT TABLE

BR-SQ-TA-1710

Page 2: SQ 1 ROOF TRUSS WEG IT TABLE

• Since truss layouts vary widely, the WEG-IT table provides open access to the entire table for 2” Steel Pucks or WEG-IT Splice & Table Jigs

• Pick and place any jig any place on the ta-ble, it’s never a re-quirement to slide a jig

• The WEG-IT solid steel top table offers

lifetime durability providing rapid, un-

encumbered use of manual jigging

• Designed to embrace the addition of

automated jigging in the table.

• The table also minimize installation,

relocation and transport challenges in-

cluding international cargo containers

• Designed to meet a variety of plant

layouts & building configurations

• The Clutter Free View: provides under

table access. No hose nor pipe shall

contact the ground in a effort to main-

tain a clean and productive work envi-

ronment

866-647-7771 [email protected] www.Square1Design.com

PURPOSE

PROCEDURE

Page 3: SQ 1 ROOF TRUSS WEG IT TABLE

Mechanical Specifications

• Laser cut structural steel tubing

• Operators Required: 1+

• Radio Transmitter: Available

• Support: Phone

Onsite ($)

• Weight per 7’x24’: up to 8,000 lbs.

• Comfortable 26-32” working height with

leveling feet on each leg

• 7’ x 24’ continuous table sections

• Compressed air storage capacity

• 3/4” steel top

• 1” WEG-IT Jigging

slots

866-647-7771 [email protected] www.Square1Design.com

SPECIFICATIONS

The Clutter Free View

PROCEDURE • The WEG-IT jigging utiliz-

es grade 5 hex head or

socket head cap screws

with hardened nuts. A

quick turn locks them in

position.

• Ejectors are operated

from the gantry’s 12”

touchscreen HMI or from

a foot valve located on

the floor.

Electrical Specifications

• Table Mounted Enclosed Conductor Rail for Gantry:

• Voltage: Amps

35...690 60 HZ 100

• Radio Transmitter

• Solenoid 24VDC or 120VAC

• Visitronics Touchscreen PLC providing:

• Magnetek radio frequency transmitter

capabilities

• Infinite pneumatic ejector selections

• Operator defined ejector area

• Wireless remote operation, eliminating

cabling

Page 4: SQ 1 ROOF TRUSS WEG IT TABLE

866-647-7771 [email protected] www.Square1Design.com

Mechanical Specifications

• 2” Sloping Ejector pockets eliminate the

need for bridge plates

• Every table can be prepared for any brand

of automated jigging, whether it is added

now to two years from today, Square 1

Design will work with any automated jig-

ging manufacturer of your choice

• The integration of the Spida Profile Auto-

mated Jigging is seamless for the custom-

er. Our staff will prepare the table, install

the mechanical features & electronic fea-

tures; then train your staff.

• The End Eject System uses a ramped in-

cline to lift the gantry above the truss

while it is being ejected. This area re-

quires a parking area of approximately 13’

from the end of the table

• The Side Eject System comes complete

with two 7’ parking areas at opposite

ends of the table

SPECIFICATIONS

Electrical Specifications

• Production metrics*

• Records number of trusses completed

per shift/day/week

• Records lineal footage completed per

shift/day/week

• Visual and audible alerts when gantry

idles past preset time (preset 15

minutes)

• ~Optional SMS/email messaging

Pneumatic Specifications

• Air requirements: 80-120 PSI

• Ejector consumption: 1.18 cubic feet / cycle

• Compressed Air Capacity: (patent pending)

112 gallons compressed air storage per 24’ of table

• 336 gallons compressed air storage

per 96’ of table

• Integration of nail, staple or air guns

connections into the table

Side Eject Specifications

• Flat ejectors raise the truss up to 7” to

transfer to a choice of transfer rollers

or receiving arms via manual labor

• Sloped ejectors raise the truss to

transfer to a choice of transfer rollers

or receiving arms via gravity

Page 5: SQ 1 ROOF TRUSS WEG IT TABLE

866-647-7771 [email protected] www.Square1Design.com

SPECIFICATIONS

Bolt

Washer

Puck

Puck Base

Puck Nut

Assembly

WEG-IT PUCKS

Closed Dimension Opened Dimension

1.1348" 0.9323"

.7908".6250"

Pneumatic Specifications

Side Eject Specifications

• Sloped ejectors raise the truss to trans-

fer to a choice of transfer rollers or re-

ceiving arms via gravity

• Pocket width is 2 1/2”

• Anti-collision safety devices are built

into the table controls to prevent the

gantry from moving when the ejectors

are in the up position

End Eject Specifications

• Flat ejectors raise the truss up to 5” to

immediately enter into the finish roller

via manual labor or powered rollers

• Pocket width will not exceed 2 1/2”

• Anti-collision safety devices are built

into the table controls to prevent the

gantry from moving when the ejectors

are in the up position

Table Mounted Conductor Rail & Trolley

Page 6: SQ 1 ROOF TRUSS WEG IT TABLE

OPTIONS

• Side Eject

• Flat ejectors or sloped ejectors

• Transfer rollers

• Receiving arms

• End Eject

• Powered or idler (std) rollers

• Compressed air under table connection

points

• Additional 3 phase voltage connection

points

• Manual hand valves

• Each table is build in 7’ x 24’ sections

and can be broken down into 8’ incre-

ments

866-647-7771 [email protected] www.Square1Design.com

Page 7: SQ 1 ROOF TRUSS WEG IT TABLE

End Eject Roof Truss Table

866-647-7771 [email protected] www.Square1Design.com

OPTIONS

Page 8: SQ 1 ROOF TRUSS WEG IT TABLE

LAYOUT

866-647-7771 [email protected] www.Square1Design.com

Page 9: SQ 1 ROOF TRUSS WEG IT TABLE

866-647-7771 [email protected] www.Square1Design.com

ADDITIONAL REASONS

TO PURCHASE

Side Eject with Transfer Roller

Sloping Ejectors

Page 10: SQ 1 ROOF TRUSS WEG IT TABLE

866-647-7771 [email protected] www.Square1Design.com

ADDITIONAL REASONS

TO PURCHASE

WEG-IT Jigging