17092 / 2617s
Sport England Type 1 MUGA Test Report
TEST REPORTFacility Address:
Facility Reference Clovenfords Primary School
Muscat BraeClovenfords Primary SchoolGalashielsTD1 3LD
SPORT ENGLANDTYPE 1 MUGA
Report Status: FINAL
Issue Date: 17/05/2016
Report Number:
Client: Scottish Borders CouncilCouncil HeadquartersNewtown St BoswellsTD6 0SA
![Page 2: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/2.jpg)
TYPE 1 MUGA Field Test Report 2/12
Clovenfords Primary School 17092 / 2617s
Sport England Type 1 MUGA Test Report
Laboratory Details
Name Sports Labs Ltd
Address 12 Nasmyth Court, Livingston, Scotland
Phone 0845 602 6354
Email [email protected]
Laboratory Director Richard Nixon
Engineer on site Neale Lees
Addtional Engineers (if any) N/A
Field Testing Manager Keith Macpherson
Prepared by
Field Testing ManagerSigned
Date 17/05/2016
Checked By
Laboratory DirectorSigned
Date 17/05/2016
![Page 3: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/3.jpg)
TYPE 1 MUGA Field Test Report 3/12
Clovenfords Primary School 17092 / 2617s
Test Summary
Summary of testing Pass/Fail FAIL
*Not all tests carried out are within our scope of ISO 17025 Accreditation.
Construction Requirements
Sport England Type 1 MUGA Test Report
Test Programme
Player/Surface Interaction Slip Resistance
Surface Regularity BS EN 13036-7: 2003
ITF CS/02/01: 1997
Dimensions* Laser Distancemeter
Permeability BS EN 12616: 2013
Slope* Using Surveyors Level
![Page 4: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/4.jpg)
TYPE 1 MUGA Field Test Report 4/12
Clovenfords Primary School 17092 / 2617s
Surface Type: MUGA
Sport England Type 1 MUGA Test Report
Test Conditions
Substrate Type: Engineered Base
Surface Name Tarmac
Surface Condition Dry
AM
SunnyWeather Conditions:
Surface Temperature (ºC) N/A
AM
Ambient Temperature (ºC) N/A
AM
Wind Speed (m/s) N/A
58
PM
Humidity (% RH) N/A
0.3
PM
PM
20
PM
20
AM
![Page 5: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/5.jpg)
TYPE 1 MUGA Field Test Report 5/12
Clovenfords Primary School 17092 / 2617s
1 2 White Yellow Red
1 2 White Yellow Red
Sport England Type 1 MUGA Test Report
Test Results
Positions
≥60 PTV
None
94
3
94 94 9692
Positions
1
87
3
Deviaitons ≥ ± 8mm
3 None
74 69 66 58 56
Surface Regularity- Total Playing Area
(See diagram Page 7)
Surface Regularity- Principal Playing Area
(See diagram Page 7)
8 Permitted
4 Permitted
Player/Surface Interaction
Wet Slip Resistance (PTV)
≥60 PTV
Dry Slip Resistance (PTV)
Values in RED denote failure of client’s specified limits
>100mm/hrPermeability
(mm/hr) 89
2
88
3
Width 18.0
Construction Requirements
Dimensions (m)
Parameter
Length 36.0
Distance (m)
0
![Page 6: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/6.jpg)
TYPE 1 MUGA Field Test Report 6/12
Clovenfords Primary School /
10
10
10
10
-9
-9
-9
-9
Irregularites ≥12 - ≤14mm
ENTRANCE
2617s17092
Sport England Type 1 MUGA Test Report
Plan showing surface irregularites > ± 8mm
Irregularites ≥15mm Irregularites ≥9 - ≤11mm
![Page 7: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/7.jpg)
TYPE 1 MUGA Field Test Report 7/12
Clovenfords Primary School 17092 / 2617s
Visual Inspection
Property Condition
Sport England Type 1 MUGA Test Report
AestheticsVisual Inspection
Line markings are broken and cracked. Re application required
Housekeeping (Litter etc)
Litter and organic detritus scattered around edges of surface
Fencing In good condition
Goals, Equipment
Equipment in good condition. Goals in good condition and no damage visible. Backboards beginning to show signs of wear
Damage Small cracks in areas.
Colour None present
Line Markings
![Page 8: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/8.jpg)
TYPE 1 MUGA Field Test Report 8/12
Clovenfords Primary School 17092 / 2617s
Sport England Type 1 MUGA Test Report
Line Markings
Sport Line Colour Number Present
Netball Yellow Not Present
Badminton Not Present Not Present
Line Markings
Hockey Not Present Not Present
Other Not Present Not Present
Tennis Not Present Not Present
5-a -Side Football White 1
Basketball Yellow 1
![Page 9: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/9.jpg)
TYPE 1 MUGA Field Test Report 9/12
Clovenfords Primary School /
00 0 0 0 0 00
1
32
3
0 0 0 0
0 0
0 0
0 0
0 0
ENTRANCE
0
0 0
0 0
0 0 0 0 0 0
0 0
0 0
2617s
Sport England Type 1 MUGA Test Report
Plan showing Test Locations
0 0 0 0
17092
0 0
![Page 10: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/10.jpg)
TYPE 1 MUGA Field Test Report 10/12
Clovenfords Primary School 17092 / 2617s
Site Photographs - Overview
Sport England Type 1 MUGA Test Report
![Page 11: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/11.jpg)
TYPE 1 MUGA Field Test Report 11/12
Clovenfords Primary School 17092 / 2617s
None FoundNone Found
uneven surfacePermebility
Sport England Type 1 MUGA Test Report
Site Photographs - Example Defects (If Any)
Broken Lines
None Found None Found
Cracking of surface
![Page 12: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas](https://reader034.fdocuments.us/reader034/viewer/2022050523/5fa64610bcc3056d9e5e8aa2/html5/thumbnails/12.jpg)
TYPE 1 MUGA Field Test Report 12/12
17092 / 2617s
Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance.
Permeability: The 3 areas examined were out with the requirements of permeability. The surface may have been designed to be no permeable
END OF REPORT
Clovenfords Primary School
Sport England Type 1 MUGA Test Report
Discussion And Conclusions
The results obtained from testing showed that the surface failed to comply with the contract specification. Details of the failures have been given below along with comments.
The surface specifically failed to meet the requirements of: