SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2...

12
17092 / 2617s Sport England Type 1 MUGA Test Report TEST REPORT Facility Address: Facility Reference Clovenfords Primary School Muscat Brae Clovenfords Primary School Galashiels TD1 3LD SPORT ENGLAND TYPE 1 MUGA Report Status: FINAL Issue Date: 17/05/2016 Report Number: Client: Scottish Borders Council Council Headquarters Newtown St Boswells TD6 0SA

Transcript of SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2...

Page 1: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

17092 / 2617s

Sport England Type 1 MUGA Test Report

TEST REPORTFacility Address:

Facility Reference Clovenfords Primary School

Muscat BraeClovenfords Primary SchoolGalashielsTD1 3LD

SPORT ENGLANDTYPE 1 MUGA

Report Status: FINAL

Issue Date: 17/05/2016

Report Number:

Client: Scottish Borders CouncilCouncil HeadquartersNewtown St BoswellsTD6 0SA

Page 2: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 2/12

Clovenfords Primary School 17092 / 2617s

Sport England Type 1 MUGA Test Report

Laboratory Details

Name Sports Labs Ltd

Address 12 Nasmyth Court, Livingston, Scotland

Phone 0845 602 6354

Email [email protected]

Laboratory Director Richard Nixon

Engineer on site Neale Lees

Addtional Engineers (if any) N/A

Field Testing Manager Keith Macpherson

Prepared by

Field Testing ManagerSigned

Date 17/05/2016

Checked By

Laboratory DirectorSigned

Date 17/05/2016

Page 3: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 3/12

Clovenfords Primary School 17092 / 2617s

Test Summary

Summary of testing Pass/Fail FAIL

*Not all tests carried out are within our scope of ISO 17025 Accreditation.

Construction Requirements

Sport England Type 1 MUGA Test Report

Test Programme

Player/Surface Interaction Slip Resistance

Surface Regularity BS EN 13036-7: 2003

ITF CS/02/01: 1997

Dimensions* Laser Distancemeter

Permeability BS EN 12616: 2013

Slope* Using Surveyors Level

Page 4: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 4/12

Clovenfords Primary School 17092 / 2617s

Surface Type: MUGA

Sport England Type 1 MUGA Test Report

Test Conditions

Substrate Type: Engineered Base

Surface Name Tarmac

Surface Condition Dry

AM

SunnyWeather Conditions:

Surface Temperature (ºC) N/A

AM

Ambient Temperature (ºC) N/A

AM

Wind Speed (m/s) N/A

58

PM

Humidity (% RH) N/A

0.3

PM

PM

20

PM

20

AM

Page 5: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 5/12

Clovenfords Primary School 17092 / 2617s

1 2 White Yellow Red

1 2 White Yellow Red

Sport England Type 1 MUGA Test Report

Test Results

Positions

≥60 PTV

None

94

3

94 94 9692

Positions

1

87

3

Deviaitons ≥ ± 8mm

3 None

74 69 66 58 56

Surface Regularity- Total Playing Area

(See diagram Page 7)

Surface Regularity- Principal Playing Area

(See diagram Page 7)

8 Permitted

4 Permitted

Player/Surface Interaction

Wet Slip Resistance (PTV)

≥60 PTV

Dry Slip Resistance (PTV)

Values in RED denote failure of client’s specified limits

>100mm/hrPermeability

(mm/hr) 89

2

88

3

Width 18.0

Construction Requirements

Dimensions (m)

Parameter

Length 36.0

Distance (m)

0

Page 6: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 6/12

Clovenfords Primary School /

10

10

10

10

-9

-9

-9

-9

Irregularites ≥12 - ≤14mm

ENTRANCE

2617s17092

Sport England Type 1 MUGA Test Report

Plan showing surface irregularites > ± 8mm

Irregularites ≥15mm Irregularites ≥9 - ≤11mm

Page 7: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 7/12

Clovenfords Primary School 17092 / 2617s

Visual Inspection

Property Condition

Sport England Type 1 MUGA Test Report

AestheticsVisual Inspection

Line markings are broken and cracked. Re application required

Housekeeping (Litter etc)

Litter and organic detritus scattered around edges of surface

Fencing In good condition

Goals, Equipment

Equipment in good condition. Goals in good condition and no damage visible. Backboards beginning to show signs of wear

Damage Small cracks in areas.

Colour None present

Line Markings

Page 8: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 8/12

Clovenfords Primary School 17092 / 2617s

Sport England Type 1 MUGA Test Report

Line Markings

Sport Line Colour Number Present

Netball Yellow Not Present

Badminton Not Present Not Present

Line Markings

Hockey Not Present Not Present

Other Not Present Not Present

Tennis Not Present Not Present

5-a -Side Football White 1

Basketball Yellow 1

Page 9: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 9/12

Clovenfords Primary School /

00 0 0 0 0 00

1

32

3

0 0 0 0

0 0

0 0

0 0

0 0

ENTRANCE

0

0 0

0 0

0 0 0 0 0 0

0 0

0 0

2617s

Sport England Type 1 MUGA Test Report

Plan showing Test Locations

0 0 0 0

17092

0 0

Page 10: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 10/12

Clovenfords Primary School 17092 / 2617s

Site Photographs - Overview

Sport England Type 1 MUGA Test Report

Page 11: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 11/12

Clovenfords Primary School 17092 / 2617s

None FoundNone Found

uneven surfacePermebility

Sport England Type 1 MUGA Test Report

Site Photographs - Example Defects (If Any)

Broken Lines

None Found None Found

Cracking of surface

Page 12: SPORT ENGLAND TYPE 1 MUGA TEST REPORT - Civica · 2016-08-30 · Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance. Permeability: The 3 areas

TYPE 1 MUGA Field Test Report 12/12

17092 / 2617s

Wet Slip Resistance: In total 2 areas were below the required limit for slip resistance.

Permeability: The 3 areas examined were out with the requirements of permeability. The surface may have been designed to be no permeable

END OF REPORT

Clovenfords Primary School

Sport England Type 1 MUGA Test Report

Discussion And Conclusions

The results obtained from testing showed that the surface failed to comply with the contract specification. Details of the failures have been given below along with comments.

The surface specifically failed to meet the requirements of: