Spectrum 50 & 100Spectrum 50 & 100FIC SystemsFIC Systems
Up to 64 Dispense PointsUp to 64 Dispense Points 1 to 4 Fluids1 to 4 Fluids Printed Dispense RecordsPrinted Dispense Records Tank Data & Low Level Tank Data & Low Level AlertAlert Simple Wiring ArchitectureSimple Wiring Architecture Built-in DiagnosticsBuilt-in Diagnostics
Spectrum 50 & 100Spectrum 50 & 100SpecificationsSpecifications
CapacityCapacity–3 or 4 fluids x 16 bays, 2 fluids x 32 bays, 1 fluid x 64 bays 3 or 4 fluids x 16 bays, 2 fluids x 32 bays, 1 fluid x 64 bays (100)(100)–2 fluids x 12 bays, 1 fluids x 24 bays (50)2 fluids x 12 bays, 1 fluids x 24 bays (50)
Meter AccuracyMeter Accuracy–1% or less error1% or less error–Custom calibration factorCustom calibration factor–Field calibration procedure Field calibration procedure
Job Queue and Concurrent DispensingJob Queue and Concurrent Dispensing–Concurrent dispense of unlike fluids onlyConcurrent dispense of unlike fluids only–Job queue of 4 jobs (plus active job) per fluidJob queue of 4 jobs (plus active job) per fluid
Spectrum 50 & 100Spectrum 50 & 100SpecificationsSpecifications
System Power and ControlSystem Power and Control–Single power input, 110 VACSingle power input, 110 VAC–Use UPS power conditioner rated 80 wattsUse UPS power conditioner rated 80 watts–Devices use 24 VDCDevices use 24 VDC–System wiring network may extend 1100 ft from the consoleSystem wiring network may extend 1100 ft from the console
Record HandlingRecord Handling–Optional Host PC interface (100): job history analysisOptional Host PC interface (100): job history analysis–Ticket PrinterTicket Printer–Internal Console storage of approx 250 job recordsInternal Console storage of approx 250 job records
Operating SecurityOperating Security–User PIN code systemUser PIN code system–4 levels of PIN security4 levels of PIN security–Start up, programming, dispense authorizationStart up, programming, dispense authorization
Spectrum 50 & 100Spectrum 50 & 100SpecificationsSpecifications
Tank Level InformationTank Level Information–Additions must be recordedAdditions must be recorded–Deletions are calculated from meter flowDeletions are calculated from meter flow–Low level prompt at consoleLow level prompt at console
Operating Pressure & Flow RangeOperating Pressure & Flow Range–Fluid valves 1500 psiFluid valves 1500 psi–Air valves 200 psiAir valves 200 psi–Impulse meters 1000 psiImpulse meters 1000 psi–Accurate flow range 0.25 to 6.0 gpmAccurate flow range 0.25 to 6.0 gpm
Ready LightsReady Lights–Installed in .500 dia sheet metal holeInstalled in .500 dia sheet metal hole
Spectrum 50 & 100Spectrum 50 & 100SpecificationsSpecifications
DiagnosticsDiagnostics–Self-test at start upSelf-test at start up–Communication self-checking during dispensesCommunication self-checking during dispenses–No-flow detection at metersNo-flow detection at meters–Coded error messages at the console displayCoded error messages at the console display
Compatible FluidsCompatible Fluids–Motor and Gear Oils, including SyntheticMotor and Gear Oils, including Synthetic–ATFATF–AntifreezeAntifreeze–WW fluid (requires special fluid solenoid valveWW fluid (requires special fluid solenoid valve
Spectrum 50 & 100Spectrum 50 & 100ComponentsComponents
ConsoleConsole– Activates jobsActivates jobs– System informationSystem information
Smart ControllerSmart Controller– 4 control ports4 control ports– Power and dispense commPower and dispense comm
Air Solenoid ValveAir Solenoid Valve– 3/8 NPT ports3/8 NPT ports– 24 VDC24 VDC
Fluid Solenoid ValveFluid Solenoid Valve– 1/2 NPT ports1/2 NPT ports– 24 VDC24 VDC
Spectrum 50 & 100Spectrum 50 & 100ComponentsComponents
Impulse MeterImpulse Meter– Use 1 per pumpUse 1 per pump– 1000 psi pressure rating1000 psi pressure rating– Calibration factor on meterCalibration factor on meter
Ready LightReady Light– Fits .500 holeFits .500 hole– Mount in reel or oil barMount in reel or oil bar
Pressure Relief Kit (not Pressure Relief Kit (not shown)shown)– Relief built in to most pumpsRelief built in to most pumps– Relief required for SpectrumRelief required for Spectrum
Y-StrainerY-Strainer– Use 1 per reelUse 1 per reel– Mount ahead of fluid valveMount ahead of fluid valve
Spectrum 50 & 100Spectrum 50 & 100ComponentsComponents
Ticket PrinterTicket Printer–Standard roll paperStandard roll paper–Reorder form for ink tapeReorder form for ink tape–6 ft from console6 ft from console
Host PC InterfaceHost PC Interface–For batch history onlyFor batch history only–1 per installation1 per installation–Cannot use with ticket Cannot use with ticket printerprinter–Complete array of reportsComplete array of reports
CablesCables–3 styles3 styles–Minimize cable runsMinimize cable runs–Available in popular lengthsAvailable in popular lengths
Spectrum 50 & 100Spectrum 50 & 100A Tour of the Service BulletinA Tour of the Service Bulletin
ContentsContents SpecificationsSpecifications Configuration PlanningConfiguration Planning InstallationInstallation OperationOperation Set Up & Diagnostic ProceduresSet Up & Diagnostic Procedures Diagnostic Message InterpretationDiagnostic Message Interpretation Repair and Upgrade ProceduresRepair and Upgrade Procedures Cable SpecsCable Specs PIN code record formPIN code record form
Spectrum 50 & 100Spectrum 50 & 100Configuration PlanningConfiguration Planning
Arrangement of InformationArrangement of Information Form Completion InstructionsForm Completion Instructions Generating the Equipment ListGenerating the Equipment List Verifying the Equipment OrderVerifying the Equipment Order Guide for InstallationGuide for Installation Guide for Repairs and UpgradesGuide for Repairs and Upgrades
Spectrum 50 & 100Spectrum 50 & 100Configuration PlanningConfiguration Planning
Working some ExamplesWorking some Examples
Spectrum 50 & 100Spectrum 50 & 100Factory ProgrammingFactory Programming
Using the Planning SheetUsing the Planning Sheet
InitializationInitialization Fluid IdentificationFluid Identification SC IdentificationSC Identification Comm Port SelectComm Port Select Set Time/DateSet Time/Date System ConfigurationSystem Configuration
Spectrum 50 & 100Spectrum 50 & 100Installation TipsInstallation Tips
Product component placementProduct component placement Wire end terminationsWire end terminations ResistorsResistors Use specified Spectrum componentsUse specified Spectrum components Lost PIN codesLost PIN codes Meter PPG valueMeter PPG value Place SC’s at a reachable heightPlace SC’s at a reachable height
Spectrum 50 & 100Spectrum 50 & 100Installation TipsInstallation Tips
Use the service manualUse the service manual Call for programming helpCall for programming help Respect distance limitsRespect distance limits Printer onPrinter on Console connectorConsole connector Power off when rewiringPower off when rewiring Train the user: operation, PIN codesTrain the user: operation, PIN codes Place SC’s at a reachable heightPlace SC’s at a reachable height
Spectrum 50 & 100Spectrum 50 & 100DiagnosticsDiagnostics
Write down complete error messageWrite down complete error message Get out the service manualGet out the service manual Get out the configuration planning sheetGet out the configuration planning sheet Call BalcrankCall Balcrank Don’t initialize the consoleDon’t initialize the console Restore by downloading backup configurationRestore by downloading backup configuration Isolate an error using zone programmingIsolate an error using zone programming
Spectrum 50 & 100Spectrum 50 & 100Diagnostics & WiringDiagnostics & Wiring
Problem Diagnostics DemoProblem Diagnostics Demo Wiring Prep Kit DemoWiring Prep Kit Demo
Spectrum 50 & 100Spectrum 50 & 100OperationOperation
Authorizing and Dispensing a JobAuthorizing and Dispensing a Job Deleting a JobDeleting a Job Jobs in QueueJobs in Queue Modifying the QueueModifying the Queue Inspecting Tank LevelsInspecting Tank Levels Recording a Tank RefillRecording a Tank Refill
Spectrum 50 & 100Spectrum 50 & 100OperationOperation
Dispense Operations DemoDispense Operations Demo