Spectra Implant System
description
Transcript of Spectra Implant System
ScrewIndirect®Screw-Receiving
Spectra-SystemSpectra-System®®CatalogCatalog
ScrewPlant®
ScrewPlus®Internal Hex
ScrewPlant®Internal Hex
ScrewRedirect®Angled Contoured
ScrewDirect®Straight Snap-on
One- and Two-Piece Implants
Bone Level 2-Stage
Tissue Level 1-Stage
GoDirect™OverDenture
Surgical Tray
4-5 ScrewPlant Implants
Table of Contents
1
2
3
6-7
8-9
10-11
16-17
14-15
22
23-25
26-28
32-33
Page #
Product Labeling:Definitions & Descriptions
ScrewPlus Implants
ScrewRedirect Implants
ScrewIndirect Implants& Components
Components for Screw-Receiving,Ball & GPS™ Abutments
ScrewDirect Implants
GoDirect Implants
FMT Packaging & Procedures forContoured Abutments
Cover Screws, Healing Collars, Transfers & Analogs
18-19
Instruments, Surgical Drills& Surgical Sequence
20-21 Selection Chart for ScrewPlant & ScrewPlus Systems
Implant Design & Surface
Application-Specific Guide
3.
7
Straight Abutment
Includes: Fixation Screw, Transfer and
Comfort Cap
1037-21 1037-21
Length: 1mm
Platform: 3.7mm Diam Straig
ht Ab
utment
# 103
7-21
xxxxxxxxxxxx
xxxxxxxxxxxx
Straig
ht Ab
utment
# 103
7-21
3.7
mmPla
tform
mmPla
tform
12-13
29-31
Prosthetic Procedures forScrewIndirect & GoDirect Implants
Zirconia,Titanium, Gold & Plastic,Engaging & Non-Engaging
Abutments
1
SBM and HA Coated Surface Options
1.2mm 0.6mm
0.6mm
1.0mm
Double Lead Threads
Quadruple Lead
Threads
The body of all Spectra-System implants are tapered evenly down from the top to facilitate insertion in an undersized socket (stopat intermediate drill) for expansion in soft bone. This increases initial stability (G. Niznick: Clinical Oral Health 2000 “Achieving Successin Soft Bone”). The SBM textured surface extends over the entire endosseous portion of the Spectra-System implants. Mini-threadsstart 1mm below the crest of the bone and extend for 2-2.5mm before transitioning into double-lead threads to the apex of theimplant. The mini-threads are half the depth and half the distance between adjacent peaks compared to the double-lead threadsthat extend to the apex of the implant. Mini-threads reduce stress in the critical crestal bone region while double-lead threads reduce the number of turns required to seat the implant. Vertical cutting grooves extend halfway up the implant from the apex forself-tapping insertion.
1.2mm 0.3mm
0.6mm
Mini-threads with Double-lead Threads for Faster Insertion
Implant Design & Surface
1.2mm
SBM surface is created by using a Soluble Blast Media of Hydroxylapatite (HA) crystals to create a medium-rough texture. We usethe same vendor for our SBM and HA coated surface treatments as was used by Paragon Implant Company from 1992-2000 when these studies were conducted.
Animal Studies Bone Response to SBM SurfaceSEMs of SurfacesMini-threads textured by blasting with SBM™: Blasted with Soluble HA ParticlesHA Coating: High Crystalline 40u layer
SBM Surface 50X
HA Surface 50X
SBM Surface 20X
HA Surface 20X
Crest of the Ridge
Application-Specific Selection Guide
2-Stage Implant 1-Stage Implant 1-Piece Implant 1-Piece Implant 1-Piece ImplantScrewPlant ScrewPlus ScrewDirect ScrewIndirect ScrewRedirect
2
1-Piece ImplantGoDirect
Application-Specific Implant System
Product Labeling: Definitions & Descriptions
3.
7 3.
7
3.7mm Diam
ScrewPlant™ Implant103713 103713
13mm 3.7mm Diam Scr
ewPla
nt# 1
0371
3xxxxxxxxxxxx
SBM™
3
.7 3.7
Screw
Plant
# 103
713
xxxxxxxxxxxx
TM TM
mm mmBo
dyPla
tform
mm mmBo
dyPla
tform
ScrewPlant Implant Vial and Cap Label
1) Our products carry the CE mark and fulfill the requirementsof the Medical Device Directive 93/42/EEC
2) Manufacturer Symbol3) Product code or reference number4) Product description5) Use before expiration date (XXXX-XX)6) Gamma sterilization symbol7) Single-use only symbol8) Caution: US law restricts the sale of these devices
by or on the order of a dentist or physician9) Tamper proof symbol
10) Refer to Instructions For Use (IFU)11) Lot number (XXXXXXXXXX)12) Implant body diameter color reference on surgical tray13) Implant prosthetic platform diameter (written and color-coded)14) Non-sterile symbol
3
1
4
5
6
7 11
12
13
8 10
10 = ScrewPlant SBM37 = 3.7mmD body diameter13 = 13mmL body length
3.
7
Straight Abutment
Includes: Fixation Screw, Transfer and
Comfort Cap
1037-21 1037-21
Length: 1mm
Platform: 3.7mm Diam Straig
ht Ab
utment
# 103
7-21
xxxxxxxxxxxx
xxxxxxxxxxxx
Straig
ht Ab
utment
# 103
7-21
3.7
mmPla
tform
mmPla
tform
ScrewPlant Prosthetic Vial and Cap Label
1mmL1037-21
3
1
4
7
8
14 11
13
13
109
10 = ScrewPlant prosthetics37 = 3.7mmD platform diameter-21= prosthetic specific code
9
2
2
3
4
ScrewPlant Two-Stage Implant System featuring:
• Internal connection with 2mm long hex & external bevel • Color-coded fixture-mount usable as a transfer & shortened for use as a straight abutment with snap-on comfort cap• 2mm extender retained by cover screw for use as a healing collar or for one-stage surgery• Surface options: SBM (Soluble Blast Media) or HA-coated• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
3.7mmDPlatform
5.7mmDPlatform
4.7mmDPlatform
Cover Screw
3.7mmDImplant
4.7mmDImplant
5.7mmDImplant
Extender
Carrier/Transfer
step 1 step 2 step 3 step 4
Fixture-Mount Transfer: Shortened for final abutment with Snap-On Comfort Cap and Transfer
Snap-OnComfort Cap
ScrewPlant
ScrewPlant Packaging
3.7mmD
SBM Code HA Code Diameter Length Platform105708 115708 5.7mmD 8mmL 5.7mmD105710 115710 5.7mmD 10mmL 5.7mmD105711 115711 5.7mmD 11.5mmL 5.7mmD105713 115713 5.7mmD 13mmL 5.7mmD105716 115716 5.7mmD 16mmL 5.7mmD
SBM Code HA Code Diameter Length Platform104708 114708 4.7mmD 8mmL 4.7mmD104710 114710 4.7mmD 10mmL 4.7mmD104711 114711 4.7mmD 11.5mmL 4.7mmD104713 114713 4.7mmD 13mmL 4.7mmD104716 114716 4.7mmD 16mmL 4.7mmD
SBM Code HA Code Diameter Length Platform103708 113708 3.7mmD 8mmL 3.7mmD103710 113710 3.7mmD 10mmL 3.7mmD103711 113711 3.7mmD 11.5mmL 3.7mmD103713 113713 3.7mmD 13mmL 3.7mmD103716 113716 3.7mmD 16mmL 3.7mmD
5.7mmD
4.7mmD
ScrewPlant: Two-Piece Implant for Two-Stage SurgeryScrewPlant
SBM and HA Surface Implants Includes Cover Screw, Fixture Mount,Extender & Comfort Cap
103708 103710 103713 103716
104708 104710 104713 104716
105708 105710 105713 105716
103711113708 113710 113713 113716113711
105711
104711114708 114710 114713 114716114711
115708 115710 115713 115716115711
5
6
ScrewPlus One-Stage Implant System featuring:
3.7mmDPlatform
5.7mmDPlatform
4.7mmDPlatform
6.5mmDPlatform
• Internal connection with 2mm long hex & external bevel • Color-coded fixture-mount usable as a transfer & shortened for use as a straight abutment with snap-on comfort cap• 2mm extender retained by cover screw for use as a healing collar • Surface options: SBM (Soluble Blast Media) or HA-coated • Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
3.7mmDImplant
4.7mmDImplant
3.7mmDImplant
5.7mmDImplant
Extender
step 1 step 2 step 3 step 4
Fixture-Mount Transfer: Shortened for final abutment with Snap-on Comfort Cap and Transfer
Carrier/Transfer
Snap-OnComfort Cap Cover Screw
ScrewPlus Packaging
ScrewPlus
7
3.7mmD
SBM Code HA Code Diameter Length Platform205708 215708 5.7mmD 8mmL 6.5mmD205710 215710 5.7mmD 10mmL 6.5mmD205711 215711 5.7mmD 11.5mmL 6.5mmD205713 215713 5.7mmD 13mmL 6.5mmD205716 215716 5.7mmD 16mmL 6.5mmD
SBM Code HA Code Diameter Length Platform203708 213708 3.7mmD 8mmL 4.7mmD203710 213710 3.7mmD 10mmL 4.7mmD203711 213711 3.7mmD 11.5mmL 4.7mmD203713 213713 3.7mmD 13mmL 4.7mmD203716 213716 3.7mmD 16mmL 4.7mmD
SBM Code HA Code Diameter Length Platform204708 214708 4.7mmD 8mmL 5.7mmD204710 214710 4.7mmD 10mmL 5.7mmD204711 214711 4.7mmD 11.5mmL 5.7mmD204713 214713 4.7mmD 13mmL 5.7mmD204716 214716 4.7mmD 16mmL 5.7mmD
SBM Code HA Code Diameter Length Platform203008 213008 3.7mmD 8mmL 3.7mmD203010 213010 3.7mmD 10mmL 3.7mmD203011 213011 3.7mmD 11.5mmL 3.7mmD203013 213013 3.7mmD 13mmL 3.7mmD203016 213016 3.7mmD 16mmL 3.7mmD
5.7mmD
4.7mmD
3.7mmD
203008213008
203010213010
203013213013
203016213016
203708213708
203710213710
203713213713
203716213716
203711213711
203011213011
ScrewPlus: Two-Piece Implant for One-Stage Surgery
205708215708
205710215710
205713215713
205716215716
205711215711
ScrewPlus
SBM and HA Surface Implants
204708214708
204710214710
204713214713
204716214716
204711214711
Includes Cover Screw, Fixture Mount,Extender & Comfort Cap
8
4.7mmDPlatform
6.5mmDPlatform
5.7mmDPlatform
3.7mmDPlatform
3.7mmDImplant
5.7mmDImplant
4.7mmDImplant
Snap-OnComfort Cap
3.0mmDImplant
• Straight abutment head with retentive groove & beveled shoulder 1.5mm above crest of bone• Double-lead threads for 2X faster insertion & quadruple-lead threads near top• Color coded plastic fixture mount usable as a snap-on transfer• Snap-on plastic comfort cap usable as coping for temporary crown• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
ScrewDirect One-PieceImplant System Featuring:
Carrier/Transfer
Snap-On Comfort Cap
Seat retentive snap-on comfort cap
Comfort cap maintains tissue opening
Seat retentive snap-on transfer
Make transfer impression forabutment analog
Snap-On Transfer
ScrewDirect Packaging
ScrewDirect
Includes Castable Coping
Code Diameter Length Platform305710 5.7mmD 10mmL 6.5mmD305713 5.7mmD 13mmL 6.5mmD305716 5.7mmD 16mmL 6.5mmD
Code Diameter Length Platform304710 4.7mmD 10mmL 5.7mmD304713 4.7mmD 13mmL 5.7mmD304716 4.7mmD 16mmL 5.7mmD
Code Diameter Length Platform303710 3.7mmD 10mmL 4.7mmD303713 3.7mmD 13mmL 4.7mmD303716 3.7mmD 16mmL 4.7mmD
Code Diameter Length Platform303010 3.0mmD 10mmL 3.7mmD303013 3.0mmD 13mmL 3.7mmD303016 3.0mmD 16mmL 3.7mmD
Straight Abutment Analog
9
5.7mmD
4.7mmD
3.7mmD
3.0mmDSBM Surface Implants
ScrewDirect: One-Piece Implant for One-Stage Surgery
303010 303013 303016
303710 303713 303716
304710 304713 304716
305710 305713 305716
Includes Carrier/Transfer & Comfort Cap
Code Platform3037 3.7mmD3047 4.7mmD3057 5.7mmD3065 6.5mmD 3047 3057 30653037
ScrewDirect
10
Snap-OnComfort CapExtender
ScrewIndirect One-PieceImplant System Featuring:
• Screw-Receiving head with retentive groove & beveled shoulder 2.5mm above bone• Double-lead threads for faster insertion, with quadruple-lead mini-threads for reduced stress concentration near crest of bone• Color-coded plastic fixture mount usable as a snap-on transfer• Snap-on plastic comfort cap• Common prosthetic platform across all four diameters of implants• Includes 2mm implant extender• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
ExtenderTransfer
Snap-On Comfort Cap and Transfer
Screw-Retained Bar Overdenture
Fixed-Detachable Restoration
Clinical Applications
Carrier/Transfer
Seat retentive snap-on comfort caps
Seat retentive snap-on transfers
5.0mmDPlatform
5.0mmDPlatform
3.7mmDImplant
5.7mmDImplant
4.7mmDImplant
3.0mmDImplant
5.0mmDPlatform
5.0mmDPlatform
ScrewIndirect Packaging
ScrewIndi rect
Code Platform Description4000-64 5.0mmD Gold Coping 4000-65 5.0mmD Titanium Coping 4000-66 5.0mmD Plastic Coping 4000-67 5.0mmD Gold & Plastic Coping 4000-69 5.0mmD Titanium Temporary Coping (includes 1000-05) 1000-01 - Replacement Fixation Screw - 2ea1000-05 - Replacement Extender Fixation Screw - 2ea
11
3.7mmD
5.7mmD
Code Diameter Length Platform403008 3.0mmD 8mmL 5.0mmD403010 3.0mmD 10mmL 5.0mmD403013 3.0mmD 13mmL 5.0mmD403016 3.0mmD 16mmL 5.0mmD
Code Diameter Length Platform403708 3.7mmD 8mmL 5.0mmD403710 3.7mmD 10mmL 5.0mmD403713 3.7mmD 13mmL 5.0mmD403716 3.7mmD 16mmL 5.0mmD
Code Diameter Length Platform405708 5.7mmD 8mmL 5.0mmD405710 5.7mmD 10mmL 5.0mmD405713 5.7mmD 13mmL 5.0mmD405716 5.7mmD 16mmL 5.0mmD
4.7mmD
Code Diameter Length Platform404708 4.7mmD 8mmL 5.0mmD404710 4.7mmD 10mmL 5.0mmD404713 4.7mmD 13mmL 5.0mmD404716 4.7mmD 16mmL 5.0mmD
404708 404710 404713 404716
405708 405710 405716
ScrewIndirect Implant Copings Includes Fixation Screw [1000-01]
405713
3.0mmDSBM Surface Implants Includes Carrier/Transfer (orange), Extender, Transfer &
Comfort Cap [Requires 2.5mmD Hex Tool]
403008 403010 403013 403016
ScrewIndirect: One-Piece Implant for One-Stage Surgery
ScrewIndi rect
Code Platform Description4000-13 5.0mmD Plastic Comfort Cap - 2ea4000-02 5.0mmD Plastic Implant Transfer - 2ea4000-62 5.0mmD Open-Tray Transfer plus Fixation Screw4000-63 5.0mmD Closed-Tray Transfer plus Fixation Screw4000-06 5.0mmD Aluminum Implant Analog1000-10 - Replacement Open-Tray Fixation Screw - 2ea1000-06 - Replacement Closed-Tray Fixation Screw - 2ea
Components for use with 2mmL ScrewIndirect Extender on pg 28
4000-62 4000-634000-02 4000-064000-13
Gold Titanium Plastic
4000-674000-654000-64 4000-66 4000-69
TitaniumGold/Plastic
403708 403710 403713 403716
ScrewIndirect Comfort Cap, Transfers & Analog
12
Snap-OnComfort Cap
GoDirect One-PieceImplant System Featuring:
• One-piece implant with GPS™ & Zest LOCATOR® compatible platform• Tapered, self-tapping body for increased stability in soft bone• 3.0mm narrow diameter implant with 1.8mm apical end allowing insertion with 2.3mmD drill• Double-lead threads for faster insertion plus quadruple-lead mini-threads for reduced stress concentration near crest of bone• Internal threads, capped off with cover screw allows for conversion to multi-unit abutment or fixed- detachable bars or bridges• All-in-1 Packaging includes snap-on transfer & comfort cap
Snap-On Comfort Cap and Transfer
Attach implant carrier as impression transfer
Attach housing for chairside pickup
Clinical Applications
Carrier/Transfer
Use plastic carrier to carry implant
Attach comfort cap to implant
3.7mmDImplant
4.7mmDImplant
3.0mmDImplant
Locator® is a registered trademark of Zest Anchors Company. The GoDirect™ and GPS™ Systems are neither authorized, endorsed nor sponsored by Zest Anchors Company
GoDirect Packaging
GoDirect
13
3.0mmD
3.7mmD
Code Diameter Length Shoulder Height423010 3.0mmD 10mmL 1.5mmL423011 3.0mmD 11.5mmL 1.5mmL423013 3.0mmD 13mmL 1.5mmL433010 3.0mmD 10mmL 3.0mmL433011 3.0mmD 11.5mmL 3.0mmL433013 3.0mmD 13mmL 3.0mmL
4.7mmD
SBM Surface Implants Includes Carrier/Transfer & Comfort Cap
423010 423013 433011423011 433010 433013
423710 423713 433711423711 433710 433713
Code Diameter Length Shoulder Height423710 3.7mmD 10mmL 1.5mmL423711 3.7mmD 11.5mmL 1.5mmL423713 3.7mmD 13mmL 1.5mmL433710 3.7mmD 10mmL 3.0mmL433711 3.7mmD 11.5mmL 3.0mmL433713 3.7mmD 13mmL 3.0mmL
Code Diameter Length Shoulder Height424708 4.7mmD 8mmL 1.5mmL424710 4.7mmD 10mmL 1.5mmL424713 4.7mmD 13mmL 1.5mmL
Code Description 1000-10 Guide Screw for GoDirect Implant - 2ea 4500-06 GoDirect Implant Analog - 1ea 4500-02 GoDirect Implant Transfer - 2ea 4500-26 GoDirect Implant Comfort Cap- 2ea 1000-97 Parallel Post - 4ea 1000-99 Plastic Abutment Angle Measure Guide
Comfort Cap, Transfer, Analog and Alignment Tools
1000-10 4500-02 4500-26 1000-97 4500-06
Code DescriptionGDT GoDirect Implant Driver Tool - (Square connection for use with Ratchet or Torque Wrench)
GDD GoDirect Implant Driver Drill - (Latch connection for use with Surgical Motor)
GDIT GoDirect Implant Tool - (Used with 4.7mmD implant)
1000-96 Core Tool - Male Removal & Seating Tool
GoDirect/GPS Instrumentation
GDT GDITGDD
1000-96
GoDirect: One-Piece Implant for One-Stage SurgeryGoDirect
424708 424713424710
1000-99
In dense bone, use CBD3.2 as final drill
In dense bone, use CBD3.7 as final drill
In dense bone, use CBD4.7 as final drill
Components for GoDirect Implants on pg 28
Overdenture, Ball & GPS Abutment for GoDirect Implant Includes Transfer & Comfort Cap[Requires 1.25mmD Hex Tool]
Code Platform Collar Heights4500-61 5.0mmD 1mm4500-71 5.0mmD 1mm4500-91 5.0mmD 1mm
4500-914500-61 4500-71
• 12° angled abutment head with contoured margins 1mm above crest of ridge• Single-lead threaded body is 0.3mm shorter than drill length to allow insertion of implant with desired direction of angled head• Double-lead mini-threads near top• Tapered body allows insertion using Zimmer Dental’s Tapered Screw-Vent® drills
ScrewRedirect PackagingScrewRedirect One-Piece Implant System featuring:
ScrewRedirect Implant Placement
Carrier
No interference if1mm clearance
Screw in using 2mm carrier/hex tool
Single lead threadsfor rotation control
Align angle & contour
Prepare as required Cement temporaryout of occlusion
3.7mmDImplant
4.7mmImplant
5.7mmDImplant
14
4.7mmDPlatform
5.7mmDPlatform
6.5mmDPlatform
ScrewRedirect
Code Description5037-07 Guide Pin for 3.7mmD Implant5047-07 Guide Pin for 4.7mmD Implant5057-07 Guide Pin for 57mmD Implant
3.7mmD
4.7mmD
5.7mmD
SBM Surface Implants
Code Diameter Length Platform503713 3.7mmD 13mmL 4.7mmD503716 3.7mmD 16mmL 4.7mmD
Code Diameter Length Platform504713 4.7mmD 13mmL 5.7mmD504716 4.7mmD 16mmL 5.7mmD
Code Diameter Length Platform505713 5.7mmD 13mmL 6.5mmD505716 5.7mmD 16mmL 6.5mmD
DoubleLead Threads
SingleLeadThreads
12o AngledAbutment Head
12o angled head of Redirect implant requires minimumof 1mm clearance on either side of implant body toallow for free rotation during implant placement.
Compatible with Zimmer’s TaperedScrew-Vent® drills
503713 503716
504713 504716
505713 505716
ScrewRedirect: One-Piece Implant for One-Stage Surgery
ScrewRedirect
15
Use after 2.3mmD Pilot Drill as a guide to ensureclearance & correct implant positioning
Guide Pin
Includes Carrier [Requires 2.0mmD Hex Tool]
5037-07 5057-075047-07
16
The implant is mounted on a color-coded fixture-mount designed for use as a transfer & shortened for use as a straight abutment. A snap-on comfort cap is provided for the modified abutment. A cover screw is included in each vial. The ScrewPlant & ScrewPlus alsoinclude a 2mm extender retained by the cover screw for use as a healing collar.
ScrewPlant & ScrewPlus Fixture-Mount Packaging
Each cap is color-coded byplatform diameter of implant
All of Implant Direct’s implantscome in a sterile vial
Each label is color-coded withtwo tear-off labels
Drop implant assembly out ofvial onto a sterile surface
Remove implant assembly witha fixture-mount drill or ratchet
Remove the holder containingthe cover screw & comfort cap
Align the flat of the fixture-mountto the buccal
Snap-on comfort cap is locatedin the top portion of holder
Prepare surgical site with doublecutting drill
Insert implant into osteotomy Index fixture-mount flat to labial
Remove fixture-mount
Remove colored section from fixture-mount through groove creating afinal straight abutment
Attach fixture-mount to corresponding color-coded implant analog
Flat of hex indexedto buccal
To attach abutment, use 30Ncmin hard bone. In soft bone, useonly finger pressure
Check for occlusal clearanceprior to attaching comfort cap
Test retention & rotate ifnecessary to increase retention
Suture soft tissue aroundcomfort cap
17
During implantplacement, indexthe flat of thefixture-mount
Pour the working castin dental stone withsoft tissue replicationmaterial
Option 2 : Stage-One transfer followed by laboratory procedures for abutment preparation & provisionalization
Attach the angledabutment to the implant analog in theworking cast with a1.25mmD hex tool
Block out the top ofthe fixture-mount& make a transfer impression
Attach the coverscrew & submergeimplant
Attach the fixture-mount to the implantanalog & seat into thenegative of the impression
Remove the fixture-mount from the working cast with the1.25mmD hex tool
Modify angle ofabutment & refine margins asrequired
Fabricate the temporary crown
Occlude screw access hole & confirm contour of restoration
Cement theprovisional restoration
At stage-2 surgery,attach the preparedabutment & tightento 30 Ncm with atorque wrench
Orienting the 15º Angled AbutmentThe flat side of the Fixture-Mount/Transfer [Fig. 1] & the angle of the 15° abutment
[Fig. 2] are manufactured to align with the flat of the implant’s internal hexagon.
Option 1 : Attaching an Angled Abutment & chairside procedures for preparation
Common procedures for abutment placement, margin finessing, impressing & placement of restoration
Remove thehealing collar with a1.25mmDhex tool
Attach provisionalrestoration & cementonto thepreparedabutment
Attach the abutmentwith the1.25mmDhex tool
Tighten to 30 Ncm witha torquewrench
Make animpressionfollowingstandardclinicalprocedures
Mark therequiredmodificationsto achieveappropriateclearance
Finesse themargins witha high-speedbur &copious irrigationprior to finalimpressing
Attach the abutment to the correspondingimplant analog& reduce theabutmentto achieveappropriateclearance
Followstandard laboratory procedures to fabricatethe finalrestoration &cement ontothe preparedabutment
Fig. 2 The two-piece, 15º AngledAbutment consists of an angled
body and a Fixation Screw
Fig. 1Fixture Mount/Transfer
Detach the abutmentwith the1.25mmDhex tool
Clinical & Laboratory Procedures for Contoured Abutments
To establish the optimum angle of the abutment,index the flat surface of the Fixture-Mount/Transfereither toward or away from the desired direction ofabutment angle at the time of implant placement.
7. Seat denture over Titanium Temporary Copings to confirm passive placement.Mark copings to indicate required verticalreduction prior to luting to denture base.
1. Use a forceps to remove the comfort caps exposing the tops of the implants.
10a & b. Attach implant replicas to copings and tighten using 1.25mmD Hex Tool. Pour aworking cast using a soft tissue replication material if required due to anatomical undercuts.
6. Confirm markings on under surface ofdenture. Use acrylic trimmer to drill holesthrough denture corresponding to markedpositions.
3. Place the fixation screw through the coping & tighten using the 1.25mmD Hex Tool. Standard torque value for fixation screws is30Ncm.
12. Attach prosthesis to implants & tighten inplace using the appropriate tooling. Occludescrew access holes with material of choice.
2. Select the Titanium Temporary Coping matching the prosthetic platform. Titanium Coping [4000-69] is supplied with fixationscrews [1000-01] and [1000-05]. An optionallonger screw [1000-10] is also available.
11. Remove prosthesis from working cast and trim to allow access for patient cleaning. The prosthesis is now a fixed restoration, removable by clinician only.
5. Mark top of Titanium Temporary Copings withindelible marker. Place denture on top of copingsto transfer their position to under surface of denture.
4. Confirm there is less than 40 degrees of relative divergence between copings to besplinted together.
8. Occlude screw access hole with cottonpellet. Use autopolymerizing acrylic or similarlight cure material to attach prosthesis toTitanium Temporary Copings. Allow to set priorto removal from mouth.
9. Remove prosthesis from the mouth and flipover to expose tissue side. Use additionalautopolymerizing resin to fill in any voidsaround the processed copings.
ScrewIndirect Implant Prosthetic Technique
4000-69 1000-101000-01
18
1000-05
6a. Transfer Process: Place the Impression Coping [4500-02] onto the implant. Injectimpression material around the coping & recorda full-arch impression.
1. Use the black plastic component to carry theGoDirect implant to site. Initiate self-tapping ofimplant into osteotomy by rotating black carrier.Remove black plastic carrier once implant is stabilized.
8. Pull on the Black Processing Male at an angle& remove it from the metal cap. If needed,wedge a tool against the bottom inside of theblack plastic to aid in removal.
5b. Chairside Process: Mark location of components on under surface of prosthesis.Relieve the areas within the prosthesis so it canbe fully seated over the metal cap without interference. Process the cap into denture following standard procedures.
10. Insert the finished prosthesis. Instruct patient on standard cleaning instructions.
2. Use either the [GDT] or [GDIT for 4.7mmD] insertion tool or [GDD] insertion drill to rotatethe GoDirect implant into the osteotomy. Stabilize the assembly with downward fingerpressure.
05a. Chairside Process: Place the White Block-Out Spacer over the head of the implant. Attachthe metal cap with Black Processing Male fromProcessing Cap/Kit [1000-98S] or [1000-98SI].
9. Use the Male Seating Tool to firmly push theReplacement Male of choice into the emptymetal cap located within the denture.
4. Attach the Parallel Posts [1000-97] to the implants to determine the divergence If the relative divergence between two assemblies isless than 20° use the white, red, orange or greenGPS Male.
7. Place the white Block-Out Spacer over thehead of the Implant Analog. Attach the metalcap with Black Processing Male. Process the denture following standard procedures.
6b. Laboratory Procedure: Insert the ImplantAnalogs [4500-06] into the Impression Copings[4500-02]. The laboratory fabricates the workingcast.
GoDirect Implant GPS Attachment Prosthetic Technique
3. The gold colored section of the implant shouldextend a minimum of 1.5mm above the soft tissue.
Bone height
Tissue height
Bone height
Tissue height
19
ScrewPlant/ScrewPlusSelection Chart
1047-93
1047-46
1047-051047-05N
1037-01 1037-131037-13N
1037-151037-15N
30371037-21 1037-22 1037-23
3037-26
3037-02
1047-40
1037-511037-52
1037-461037-40 1037-47 1037-49
1037-051037-05N
1037-081037-08N
1037-06 1047-01 1047-131047-13N
1047-151047-15N
Fixture MountScrewPlant
20
4.7mmD
1037-30L
1037-61 1037-62 1037-64
1037-91 1037-93 1037-941037-92
1037-71 1037-73 1037-741037-72
1047-61 1047-62
1047-91 1047-92
1047-71 1047-72
1037-21N1037-22N
Fixture MountScrewPlus
Fixture MountScrewPlant
3.7mmD Platform
3047
3047-26
3047-021047-21N1047-22N
2047-20
1037-95
1047-511047-52
Cover Screws, Healing Collars,
Implant Transfers& Analogs
Straight Abutments,Comfort Caps, Transfers
& Analogs
Engaging &Non-Engaging
Abutments
Ball, Screw-Receiving& GPS Abutments
Straight & AngledContoured &LaboratoryAbutments 1047-51-15C
1047-52-15C1047-311047-32
1047-31C1047-32C
1037-51-08C1037-52-08C
1037-51-15C1037-52-15C
1037-31C1037-32C
1037-311037-32
5.7mmD Platform 6.5mmD Platform
Fixture MountScrewPlus
30571057-21 1057-22 1057-23
3057-26
3057-02 3065-02 30652065-20
3065-26
1057-31 1057-32 1057-51 1057-52 1057-30L
1057-40 1057-46 1057-47 1057-49 2065-40 2065-46 2065-47 2065-49
1057-93 1057-941057-92 1057-95
Fixture MountScrewPlus
Fixture MountScrewPlant
21
1047-47 1047-49
1047-081047-08N
1047-06 1057-01 1057-13 1057-15 1057-05 1057-08 1057-06 2065-01 2065-13 2065-15 2065-05 2065-08 2065-06
Fixture MountScrewPlus
1047-64 1057-61 1057-62 1057-64
1057-71 1057-73 1057-741057-72
1047-21 1047-22 1047-23 2057-20
1047-73 1047-74
1047-94 1047-95
Platform
1047-30L1047-51-08C1047-52-08C
22
Code Platform1037-06 3.7mmD1047-06 4.7mmD1057-06 5.7mmD2065-06 6.5mmD
Code Platform1037-01 3.7mmD1047-01 4.7mmD1057-01 5.7mmD2065-01 6.5mmD
Replacement Surgical Cover Screws
1037-01 1047-01 1057-01 2065-01
Implant Analogs
2065-061057-061037-06 1047-06
Code Platform Width Length1037-13N 3.7mmD 3.8mmD 3mmL1037-13 3.7mmD 4.8mmD 3mmL1037-15N 3.7mmD 3.8mmD 5mmL1037-15 3.7mmD 4.8mmD 5mmL1047-13N 4.7mmD 4.8mmD 3mmL1047-13 4.7mmD 5.8mmD 3mmL1047-15N 4.7mmD 4.8mmD 5mmL1047-15 4.7mmD 5.8mmD 5mmL1057-13 5.7mmD 6.6mmD 3mmL1057-15 5.7mmD 6.6mmD 5mmL2065-13 6.5mmD 7.4mmD 3mmL2065-15 6.5mmD 7.4mmD 5mmL
Healing Collars Requires 1.25mmD Hex Tool
Requires 1.25mmD Hex Tool
Cover Screws, Healing Collars, Transfers & Analogs
Closed-Tray Implant Transfers
Code Platform Replacement Screw1037-05N 3.7mmD 1000-061037-05 3.7mmD 1000-061047-05N 4.7mmD 1000-061047-05 4.7mmD 1000-061057-05 5.7mmD 1000-062065-05 6.5mmD 1000-06
1047-05N
1037-05 1057-05
2065-05
1000-06
Includes Fixation Screw
1047-05
Open-Tray Implant Transfers
Code Platform Replacement Screw1037-08N 3.7mmD 1000-101037-08 3.7mmD 1000-101047-08N 4.7mmD 1000-101047-08 4.7mmD 1000-101057-08 5.7mmD 1000-102065-08 6.5mmD 1000-10
1047-08N
1037-08
2065-08
1000-10
Includes Fixation Screw
1047-08
1037-08N
1047-13N
1047-13 1057-13 2065-13
1037-15 1047-15 1057-15 2065-15
1037-13N
1037-13
1037-15N 1047-15N
1037-05N
1057-08
Straight Abutments
Straight Abutment Transfers
Straight Abutment Comfort Caps
Straight Abutment Castable Copings
Straight Abutment Analogs
Code Platform3037-26 3.7mmD3047-26 4.7mmD3057-26 5.7mmD3065-26 6.5mmD
Code Abutment Width3037-02 3.7mmD3047-02 4.7mmD3057-02 5.7mmD3065-02 6.5mmD
3037-02
Code Platform3037 3.7mmD3047 4.7mmD3057 5.7mmD3065 6.5mmD
3047 3057 30653037
Code Platform3037-28 3.7mmD3047-28 4.7mmD3057-28 5.7mmD3065-28 6.5mmD
Includes Castable Coping
3047-28 3057-28 3065-283037-28
3047-02 3057-02 3065-02
3047-26 3057-26 3065-263037-26
Code Platform Collar Heights Use Analog1037-21N 3.7mmD 1mm 30371037-22N 3.7mmD 2mm 30371037-21 3.7mmD 1mm 30471037-22 3.7mmD 2mm 30471037-23 3.7mmD 3mm 30472047-20 4.7mmD 0mm 3047
1047-21N 4.7mmD 1mm 30471047-22N 4.7mmD 2mm 30471047-21 4.7mmD 1mm 30571047-22 4.7mmD 2mm 30571047-23 4.7mmD 3mm 30572057-20 5.7mmD 0mm 30571057-21 5.7mmD 1mm 30651057-22 5.7mmD 2mm 30651057-23 5.7mmD 3mm 30652065-20 6.5mmD 0mm 3065
1037-21
1037-22
1037-23
1047-21
1047-22
1047-23
2047-201057-21
1057-22
1057-23
2057-20
2065-20
Includes Transfer, Comfort Cap & Fixation Screw [1000-01]
Straight Abutments, Snap-on Transfers and Lab Analogs
23
1037-22N 1047-22N
1047-21N1037-21N
Includes two pieces
Includes two pieces
Includes two pieces
Includes Fixation Screw [1000-01]
Includes Fixation Screw [1000-01]
Includes Fixation Screw [1000-01]
Includes Fixation Screw [1000-01]
Straight & Angled Contoured, Titanium & Zirconia Abutments
Angled Titanium Contoured Abutments
Code Platform Angulation Collar Heights1037-51 3.7mmD 15° 1mm1037-52 3.7mmD 15° 2mm1047-51 4.7mmD 15° 1mm1047-52 4.7mmD 15° 2mm1057-51 5.7mmD 15° 1mm1057-52 5.7mmD 15° 2mm 1037-52 1047-52 1057-52
Straight Titanium Contoured Abutments
Code Platform Collar Heights1037-31 3.7mmD 1mm1037-32 3.7mmD 2mm1047-31 4.7mmD 1mm1047-32 4.7mmD 2mm1057-31 5.7mmD 1mm1057-32 5.7mmD 2mm
24
Straight Zirconia Contoured Abutments
Code Platform Collar Heights1037-30CB 3.7mmD .5mm1037-31C 3.7mmD 1.5mm1037-32C 3.7mmD 2.5mm1047-30CB 4.7mmD .5mm1047-31C 4.7mmD 1.5mm1047-32C 4.7mmD 2.5mm
Code Platform Angulation Collar Heights1037-51-08C 3.7mmD 8° 1.5mm1037-51-15C 3.7mmD 15° 1.5mm1037-52-08C 3.7mmD 8° 2.5mm1037-52-15C 3.7mmD 15° 2.5mm1047-51-08C 4.7mmD 8° 1.5mm1047-51-15C 4.7mmD 15° 1.5mm1047-52-08C 4.7mmD 8° 2.5mm1047-52-15C 4.7mmD 15° 2.5mm
1047-51-15C 1047-52-08C1047-51-08C
1037-51-15C 1037-52-08C1037-51-08C
1047-52-15C
1037-52-15C
1037-31 1047-31 1057-31
1037-32 1047-32 1057-32
1037-30CB 1037-31C 1037-32C
1047-30CB 1047-31C 1047-32C
1037-51 1047-51 1057-51
8° & 15° Zirconia Contoured Abutments
Code Description1000-01 Short Fixation Screw1000-06 Fixation Screw1000-10 Long Fixation Screw
Code Platform Collar Heights1037-30L 3.7mmD 1mm1047-30L 4.7mmD 1mm1057-30L 5.7mmD 1mm
25
Replacement Fixation Screws
1000-01 1000-06 1000-10
Abutments
Open-TrayTransfer &
Waxing Screw
Includes Fixation Screw [1000-01]
1037-30L 1047-30L 1057-30L
Lab, Engaging & Non-Engaging Abutments
Plastic Non-Engaging Castable Abutments
Code Platform Collar Heights1037-46 3.7mmD 0mm1047-46 4.7mmD 0mm1057-46 5.7mmD 0mm2065-46 6.5mmD 0mm4500-46 GoDirect Implant only 0mm
Includes Fixation Screw [1000-01]
Includes Fixation Screw [1000-01]Gold Engaging Cast-to Abutments
Code Platform Collar Heights1037-40 3.7mmD 1mm1047-40 4.7mmD 1mm1057-40 5.7mmD 1mm2065-40 6.5mmD 1mm
1037-40 1047-40 1057-40 2065-40
1037-46 1047-46 1057-46
2065-46 4500-46
Includes Fixation Screw [1000-06]Plastic Engaging Temporary Abutments
Code Platform Collar Heights1037-47 3.7mmD 0mm1047-47 4.7mmD 0mm1057-47 5.7mmD 0mm2065-47 6.5mmD 0mm 1037-47 1047-47 1057-47 2065-47
Includes Fixation Screw [1000-01]
Code Platform Collar Heights1037-49 3.7mmD 0mm1047-49 4.7mmD 0mm1057-49 5.7mmD 0mm2065-49 6.5mmD 0mm 1037-49 1047-49 1057-49 2065-49
Closed-Tray Transfer &Temporary Abutment
Full Contour Platform Switching Abutments
Titanium Non-Engaging Temporary Abutments
Includes two pieces
**1000-84**1000-87 1000-85 1000-81 1000-82 1000-88 1000-83 1000-86
*1000-68*4000-13
Open-Tray Transfer Closed-Tray Transfer
Gold Titanium Plastic Gold/Plastic Titanium
1000-61 1000-62 1000-63
1000-64 1000-65 1000-66 1000-67 1000-69
26
6.5mmDPlatform
3.7mmDPlatform
4.7mmDPlatform
5.7mmDPlatform
Selection Chart: Overdenture & Screw-Retained Restorations
BallAbutment
Components
Ball Abutments
OverdentureAbutments
Overdenture Screw-Retained Copings
OverdentureAbutment
Components
1037-611037-621037-64
1047-611047-621047-64
1057-611057-621057-64
Screw-Receiving Overdenture Abutment Transfers, Analog & Comfort Cap
Ball Abutments (**Includes Transfer and Comfort Cap)
Ball Attachments
GPSAbutment
Components
GPSAbutments
GPS Abutments (***Includes Transfer, Abutment Housing Kit and Comfort Cap)
GPS Attachments
OD AbutmentComfort Cap
Transfers & Analog
1037-711037-721037-731037-74
1047-711047-721047-731047-74
1057-711057-721057-731057-74
1047-911047-921047-931047-94
1057-921057-931057-94
1037-911037-921037-931037-941037-95 1047-95 1057-95
***1000-94
1000-92C
1000-95
1000-92E
1000-98S1000-93 1000-96***4500-26
1000-92R1000-92G ***1000-91
1000-92B1000-92P 1000-92W 1000-98SI
Screw-Receiving Overdenture Abutments (*Includes Transfer and Comfort Cap)
Screw-Receiving Overdenture Abutments Includes Transfer & Comfort Cap[Requires 1.25mmD Hex Tool]
Code Platform Collar Heights1037-61 3.7mmD 1mm1037-62 3.7mmD 2mm1037-64 3.7mmD 4mm1047-61 4.7mmD 1mm1047-62 4.7mmD 2mm1047-64 4.7mmD 4mm1057-61 5.7mmD 1mm1057-62 5.7mmD 2mm1057-64 5.7mmD 4mm
1037-61
1057-61 1057-62
1047-61
Ball Abutments Includes Transfer & Comfort Cap[Requires 1.25mmD Hex Tool]
Code Platform Collar Heights1037-71 3.7mmD 1mm1037-72 3.7mmD 2mm1037-73 3.7mmD 3mm1037-74 3.7mmD 4mm1047-71 4.7mmD 1mm1047-72 4.7mmD 2mm1047-73 4.7mmD 3mm1047-74 4.7mmD 4mm1057-71 5.7mmD 1mm1057-72 5.7mmD 2mm1057-73 5.7mmD 3mm1057-74 5.7mmD 4mm 1057-73 1057-741057-721057-71
GPS Abutments Includes Transfer, Comfort Cap, GPS Abutment Housing Kit, & Clear Male Liner[Requires 1.25mmD Hex Tool] *Abutment only
Code Platform Collar Heights1037-91 3.7mmD 1mm1037-92 3.7mmD 2mm1037-93 3.7mmD 3mm1037-94 3.7mmD 4mm1037-95 3.7mmD 5mm1047-91 4.7mmD 1mm1047-92 4.7mmD 2mm1047-93 4.7mmD 3mm1047-94 4.7mmD 4mm1047-95 4.7mmD 5mm1057-92 5.7mmD 2mm1057-93 5.7mmD 3mm1057-94 5.7mmD 4mm1057-95 5.7mmD 5mm4000-92 ScrewIndirect GPS Abutment 2mm2000-92 GPS Bar Abutment with M2 thread—2 ea*
Screw-Receiving, Ball & GPS Abutments
27
1057-93 1057-941057-92 1057-95
1037-64
1047-62 1047-64
1057-64
1037-62
1037-72 1037-731037-71 1037-74
1047-72 1047-731047-71 1047-74
1047-921047-91 1047-94 1047-951047-93
1037-931037-921037-91 1037-94 1037-95
4000-92 2000-92
Overdenture Abutment Components
GPS Instrumentation
Ball Abutment Components
Includes Fixation Screw [1000-05]
Code Platform Description1000-61 5.0mmD Aluminum Analog1000-62 5.0mmD Open-Tray Transfer plus Fixation Screw1000-63 5.0mmD Closed-Tray Transfer plus Fixation Screw1000-68 5.0mmD Plastic Abutment Transfer - 2ea4000-13 5.0mmD Plastic Comfort Cap - 2ea1000-14 - Replacement Open-Tray Fixation Screw - 2ea1000-15 - Replacement Closed-Tray Fixation Screw - 2ea
Code Description 1000-94 Impression Coping - 2ea 1000-95 Abutment Analog 4mmD - 2ea 1000-97 Abutment Parallel Post - 4ea 1000-10 Guide Screw for ScrewPlant/ScrewPlus - 2ea 4500-26 Comfort Cap - 2ea 1000-99 Plastic Abutment Angle Measure Guide
Code Description1000-81 Ball Abutment Housing - 2ea1000-82 Nylon Liner - 2ea1000-83 Nylon Liner Transfer - 2ea1000-84 Ball Abutment Transfer - 2ea1000-85 Ball Abutment Analog1000-86 Ball Abutment Tools1000-87 Ball Abutment Comfort Cap - 2ea1000-88 Ball Abutment Housing & Nylon Liner
28
GPS Abutment Transfer, Analogs & Alignment Tools
Ancillary Components for Overdenture & Screw-Retained Restorations
Screws require 1.25mmD Hex ToolOverdenture Abutment Comfort Cap, Transfers & Analog
Code Platform Description1000-64 5.0mmD Gold Coping1000-65 5.0mmD Titanium Coping1000-66 5.0mmD Plastic Coping1000-67 5.0mmD Gold & Plastic Coping1000-69 5.0mmD Titanium Temporary Coping 1000-05 - Coping Fixation Screw - 2ea
Code Description1000-96 Core Tool - Male Removal & Seating Tool
Code Retention Force Description 1000-92W 5.0lbs Internal Replacement Male White - 4ea 1000-92P 3.0lbs Internal Replacement Male Pink - 4ea 1000-92B 1.5lbs Internal Replacement Male Blue - 4ea 1000-92C 4.5lbs External Replacement Male Clear - 4ea 1000-92G 3.0lbs External Replacement Male Green - 4ea 1000-92E 2.0lbs External Replacement Male Orange - 4ea 1000-92R 1.0lb External Replacement Male Red - 4ea 1000-91 - GPS Abutment Housing Kit - 1ea 1000-93 - Black Processing Male - 4ea 1000-98SI Assorted Internal Processing Cap/Male Kit - 1ea 1000-98S Assorted External Processing Cap/Male Kit - 1ea
GoDirect & GPS Abutment Components
1000-82
1000-84
1000-861000-85 1000-87 1000-88
1000-831000-81
1000-681000-61 1000-62 1000-63 4000-13
1000-99
1000-97
1000-95
4500-26
1000-94
1000-93
1000-92B
1000-92E
1000-92P
1000-92C
1000-98S
1000-661000-65 1000-671000-05 1000-64 1000-69
1000-92R
1000-92G
1000-92W
1000-98SI
1000-91
1000-96
1000-10
Code DescriptionHT1.25L 1.25mmD Straight Hex Tool Extra Long (For use with Torque Wrench)
HT1.25 1.25mmD Straight Hex Tool Long (For use with Torque Wrench)
HT1.25S 1.25mmD Straight Hex Tool Short (For use with Torque Wrench)
HT2.0 2.0mmD Straight Hex Tool LongHT2.0S 2.0mmD Straight Hex Tool ShortHT2.5 2.5mmD Straight Hex Tool Long (with retentive O-ring)
HT2.5S 2.5mmD Straight Hex Tool Short (with retentive O-ring)
HT3.0 3.0mmD Straight Hex Tool LongHT3.0S 3.0mmD Straight Hex Tool-Short
Square connection for use with Ratchet or Torque Wrench
Code DescriptionST Empty Surgical Kit for Spectra System Implants
BST Basic Surgical Kit for Spectra System ImplantsCST Complete Surgical Kit for Spectra System Implants
Surgical & Prosthetic Instruments
29
Tapered Hex Tools
Code DescriptionTHT1.25 1.25mmD Tapered Hex Tool-Long
THT1.25S 1.25mmD Tapered Hex Tool-Short
Code DescriptionHD1.25 1.25mmD Hex DrillHD2.0 2.0mmD Hex DrillHD2.5 2.5mmD Hex Drill (with retentive O-ring)HD3.0 3.0mmD Hex Drill
Latch head connection for use with Surgical Motor
Code DescriptionR Ratchet
TW30 30Ncm Torque WrenchTW35 35Ncm Torque Wrench
SSH2.5 2.5mmD Stainless Steel Handle (with retentive O-ring)
FMD Fixture Mount Drill (with retentive O-ring)
PAR Paralleling Tool 2.8/2.3LDRILL Locator Drill (2.3mmD)
DE Drill ExtenderTWM Multi-Setting Torque Wrench (15, 20, 25, 30, 35, 40, 45, 50 & 60Ncm)
ABH Analog Holder
Straight Hex Tools
Hex Drills
Surgical Trays
Ancillary Instruments
HT3.0HT2.5HT2.0HT1.25
HT2.5S HT3.0SHT2.0SHT1.25S
THT1.25STHT1.25
HD1.25 HD3.0HD2.0 HD2.5
R TW30
PARFMD DELDRILL
ABH
TWM
ST CSTBST
HT1.25L
TW35 SSH2.5
30
3.0mmD Implants
Code DescriptionSD2.3 2.3/2.0mmD Step Drill with 6-16 markings
SD2.3S 2.3/2.0mmD Step Drill with 6-10 markingsSD2.8 2.8/2.3mmD Step Drill with 6-16 markings
SD2.8S 2.8/2.3mmD Step Drill with 6-10 markingsCBD3.2 Cortical Bone Drill for 3.0 and 3.2mmD Implants
Surgical Drills
3.7mmD Implants
Code DescriptionSD3.4 3.4/2.8mmD Step Drill with 6-16 markings
SD3.4S 3.4/2.8mmD Step Drill with 6-10 markingsCBD3.7 Cortical Bone Drill for 3.7mmD Implants
4.7mmD Implants
Code DescriptionSD4.4 4.4/3.8mmD Step Drill with 6-16 markings
SD4.4S 4.4/3.8mmD Step Drill with 6-10 markingsCBD4.7 Cortical Bone Drill for 4.7mmD Implants
Optional Drills
Code DescriptionSD3.8 3.8/3.4mmD Step Drill with 6-16 markings
SD3.8S 3.8/3.4mmD Step Drill with 6-10 markingsCBD4.2 Cortical Bone Drill for 4.2mmD Implants
5.7mmD Implants
Code DescriptionD5.1 5.1mmD Straight Drill with 6-16 markings
D5.1S 5.1mmD Straight Drill with 6-10 markingsSD5.4 5.4/4.8mmD Step Drill with 6-16 markings
SD5.4S 5.4/4.8mmD Step Drill with 6-10 markingsCBD5.7 Cortical Bone Drill for 5.7mmD Implants
Optional Drills
Code DescriptionSD4.8 4.8/4.4mmD Step Drill with 6-16 markings
SD4.8S 4.8/4.4mmD Step Drill with 6-10 markingsCBD5.2 Cortical Bone Drill for 5.2mmD Implants
SD2.3 SD2.3S SD2.8 SD2.8S CBD3.2
SD3.4 SD3.4S CBD3.7
SD4.4 SD4.4S
SD3.8 SD3.8S
D5.1 D5.1S SD5.4 SD5.4S
SD4.8 SD4.8S
CBD4.2
CBD4.7
CBD5.2
CBD5.7
SD4.44.4/3.8mmD
CBD4.7SD3.83.8/3.4mmD
SD3.43.4/2.8mmD
SD2.82.8/2.3mmD
Optional
SD2.32.3/2.0mmD
Dense Bone FinalSoft Bone Final OptionalBone Contour
SD2.82.8/2.3mmD
CBD3.2SD2.32.3/2.0mmD
Dense Bone FinalSoft Bone Final OptionalBone Contour
SD4.44.4/3.8mmD
SD4.84.8/4.4mmD
SD3.83.8/3.4mmD
SD5.45.4/4.8mmD
CBD5.7D5.1 5.1mmD
SD3.43.4/2.8mmD
SD2.82.8/2.3mmD
Optional OptionalOptional
SD2.32.3/2.0mmD
Dense Bone FinalSoft Bone Final OptionalBone Contour
SD3.43.4/2.8mmD
CBD3.7SD2.82.8/2.3mmD
SD2.32.3/2.0mmD
Dense Bone FinalSoft Bone Final OptionalBone Contour
31
Spectra System Drill Sequence
3.0mmD Tapered Implant Body
3.7mmD Tapered Implant Body
4.7mmD Tapered Implant Body
5.7mmD Tapered Implant Body
32
THT1
.25S
HT1
.25S
HT2
.0S
HT2
.5S
HT3
.0S
THT1
.25
PAR
(4)
LDRI
LLD
E
R
SSH
2.5
HT1
.25
HT2
.0H
T2.5
HT3
.0
Complete Surgical Tray Contents
HD
2.0
HD
1.25
FMD
HD
3.0
HD
2.5
SD3.
4SD
3.4S
SD2.
8SD
2.8S
SD3.
8SD
3.8S
SD4.
4SD
4.4S
SD4.
8SD
4.8S
D5.
1D
5.1S
SD2.
3SD
2.3S
SD5.
4SD
5.4S
Low
er le
vel o
f sur
gica
l tra
y
CBD
5.2
CBD
4.7
CBD
4.2
CBD
3.7
CBD
3.2
CBD
5.7
33
Surgical Tray
Inside EmptyTray
Lid
Surgical Tray Contents Complete Kit Basic Kit Conversion KitCode Description
ST Empty Surgical Tray X X XSD2.3 2.3/2.0mmD Step Drill-Long X X
SD2.3S 2.3/2.0mmD Step Drill-Short XSD2.8 2.8/2.3mmD Step Drill-Long X X
SD2.8S 2.8/2.3mmD Step Drill-Short XCBD3.2 3.2mmD Cortical Drill X XSD3.4 3.4/2.8mmD Step Drill-Long X X
SD3.4S 3.4/2.8mmD Step Drill-Short XCBD3.7 3.7mmD Cortical Drill X XSD3.8 3.8/3.4mmD Step Drill-Long X X X
SD3.8S 3.8/3.4mmD Step Drill-Short X XCBD4.2 4.2mmD Cortical Drill X XSD4.4 4.4/3.8mmD Step Drill-Long X X
SD4.4S 4.4/3.8mmD Step Drill-Short XCBD4.7 4.7mmD Cortical Drill X XSD4.8 4.8/4.4mmD Step Drill-Long X X X
SD4.8S 4.8/4.4mmD Step Drill-Short X XCBD5.2 5.2mmD Cortical Drill X X
D5.1 5.1mmD Straight Drill-Long X XD5.1S 5.1mmD Straight Drill-Short XSD5.4 5.4/4.8mmD Step Drill-Long X X
SD5.4S 5.4/4.8mmD Step Drill-Short XCBD5.7 5.7mmD Cortical Drill X X
Hex ToolsTHT1.25 1.25mmD Tapered Hex Tool-Long X X
THT1.25S 1.25mmD Tapered Hex Tool-Short XHT1.25 1.25mmD Straight Hex Tool-Long X X
HT1.25S 1.25mmD Straight Hex Tool-Short XHT2.0 2.0mmD Straight Hex Tool-Long X X
HT2.0S 2.0mmD Straight Hex Tool-Short XHT2.5 2.5mmD Straight Hex Tool-Long X X
HT2.5S 2.5mmD Straight Hex Tool-Short XHT3.0 3.0mmD Straight Hex Tool-Long X X
HT3.0S 3.0mmD Straight Hex Tool-Short XHD1.25 1.25mmD Hex Drill X XHD2.0 2.0mmD Hex Drill X XHD2.5 2.5mmD Hex Drill X XHD3.0 3.0mmD Hex Drill X X
Ancillary InstrumentationFMD Fixture Mount Drill X
LDRILL Locator Drill X XDE Drill Extender X XR Ratchet X X
PAR (x4) Paralleling Tool 2.8/2.3 X XSSH2.5 2.5mmD Stainless Steel Handle X
All trademarks are property of their respective companies.
www.implantdirect.com | 888-649-6425
Designed For Success,Packaged For Value
ScrewPlant and ScrewPlus Implant Advantages:
All-in-1 Packaging includes implant, abutment,transfer, cover screw, healing collar & comfort cap
ScrewPlant® and ScrewPlus® Implants
ScrewPlantBone Level
2-Stage
ScrewPlusTissue Level
1-Stage Internal Hex with External BevelInternal Hex connection prevents rotation of prosthetic componentsExternal Bevel for added support
Surgical Compatibility with Tapered Screw-Vent®No need to change surgical protocol or tools
Micro-ThreadsReduce crestal stress for improved initial stability
Double-Lead ThreadsFor faster insertion with Standard “V” threads matching Screw-Vent®
Tapered BodyFacilitates soft bone expansion
Reality Check
Zimmer Customers
Cover ScrewComfort Cap Healing Collar
Customer Service &
Technical Support
online, over thephone, or in your office
*5-01-12-0045* 5K-01-12-0045i Printed in the U.S.A. Copyright © 2011 Implant Direct Sybron International. All Rights Reserved