Special Medical Technology · 2016-02-08 · •Adenomyosis uteri (uterine endometriosis)...
Transcript of Special Medical Technology · 2016-02-08 · •Adenomyosis uteri (uterine endometriosis)...
Special Medical Technology
www.smt-praha.com
Content
Introduction
Electrosurgery
Cryosurgery
Thermosurgery
Certification
Contacts
Specialization
www.smt-praha.com
About us
www.smt-praha.com
• Company name: Speciální Medicínská Technologie Special Medical Technology
• SMT was founded in 1990
• We are manufacturer and seller of Electrosurgical and
Cryosurgical devices and accessory
• Certifications: Quality System ISO 13485:2003 CE MARK 1014 Free Sales Certificate (FSC)
• Located in Prague, Czech Republic, Europe
We have exported to 52 countries:
www.smt-praha.com
About us
What we do
Surgery
Dermatology
Gynecology
Dentistry
Ophthalmology
ENT
Endoscopy
Veterinary
Cosmetics
www.smt-praha.com
The company's orientation and main operational areas include the development, design, manufacture, sales and service of the ELECTROSURGICAL and CRYOSURGICAL systems, instruments, tools and accessories for various human medical specializations.
Cryosurgical and Electrosurgical devices designed for:
www.smt-praha.com
General information
High frequency / Radio Frequency
Electrosurgery / electrocautery / diathermy
Monopolar and bipolar
Cut, coagulate or fulgurate tissue
Electrosurgery
www.smt-praha.com
General information: Electrosurgery is the application of a high-frequency electric current to biological tissue as a means to cut, coagulate or fulgurate tissue. Its benefits include the ability to make precise cuts with limited blood loss
HF /RF Electrosurgery systems
Electrosection
Electrocoagulation
Electrodessication
Electrofulguration
Epilation
Electrosurgery
Electrosurgery
www.smt-praha.com
The electric current never comes into contact with the patient.
Dielectric heating, produced by rotation of molecular dipoles in high frequency alternating electric field. This effect is most widely used in microwave ovens which operate at gigahertz frequencies.
Electrocautery
Diathermy
Electrosurgery
www.smt-praha.com
In Electrosurgery the electricity used is not ordinary domestic electric power, but something nearer to radio waves. Always alternating current, the frequency involved is typically around 200,000 cycles per second (200KiloHertz)
The reason for use of high frequency is that such a form of electric current can pass through the body without causing Electric Shock
In 95% cases we can say that Electrosurgical device = Electrocautery or Diathermy device
Electrosurgery
Electrosurgery
www.smt-praha.com
• Radio frequency (RF) is a rate of oscillation in the range of around 200 kHz to 4MHz, which corresponds to the frequency of radio waves, and the alternating currents which carry radio signals.
• SMT devices work at 460 kHZ!
Radio frequency (RF)/ High Frequency (HF)
Electrosurgery
www.smt-praha.com
Monopolar
Electrosurgery
www.smt-praha.com
Monopolar vs. Bipolar
www.smt-praha.com
Cut, coagulate or fulgurate tissue
Electrosurgery
Power 60W
Outputs CUT, BLEND, COAG
Modes Monopolar or Bipolar
Dimensions 2 45x160x75 mm
Switch: Foot controlled pneumatic (M & B) and hand controlled for
Neptun
SMT ESU 60 M SMT ESU 60 B SMT ESU 60 Neptun
www.smt-praha.com
Electrosurgery
Power 75 W (in monopolar mode at loading 500 Ohms)
Outputs CUT, BLEND, COAG, MICRO (EPI)
Modes Monopolar and Bipolar for all outputs
Dimensions 245x250x75 mm
Switch Foot controlled pneumatic
SMT 75 MB
www.smt-praha.com
Electrosurgery
SMT BM
Power 100; 125; 170W
Outputs CUT, BLEND, COAG, MICRO (EPI)
Modes Monopolar and Bipolar for all outputs
Dimensions 250x290x75 mm
Switch Foot controlled pneumatic
www.smt-praha.com
Electrosurgery
SMT BM M
Power 150; 200; 250; 300; 350; 400 W
Outputs CUT, BLEND, COAG, MICRO, SPRAY
Modes Monopolar and Bipolar for all outputs
Dimensions 310x290x75 mm
Switch Hand (electric) / Foot (pneumatic)
www.smt-praha.com
Electrosurgery
SMT BM M PF
Power 150; 200; 250; 300; 350; 400 W
Outputs CUT, BLEND, COAG, MICRO, SPRAY
Modes Monopolar and Bipolar for all outputs
Dimensions 335x330x100 mm
Switch Hand (electric) / Foot (pneumatic)
www.smt-praha.com
Programmable – up to 12 programs
Electrosurgery
SMT ElectroDENT
Power 75 W (in monopolar mode at loading 500 Ohms)
Outputs CUT, BLEND, COAG
Mode Monopolar
Dimensions 250x290x75 mm
Switch Foot controlled pneumatic
www.smt-praha.com
Electrosurgery
SMT EPI 2000 ZW
Power: 10 W
Fastening diameter of electrode: 0,8 mm
Operational applicator: 9x130 mm
Dimensions: 200x210x40 mm
Switch: Foot controlled pneumatic
www.smt-praha.com
Electrosurgery
SMT BM VET
Power: 120; 140; 180W (in monopolar mode at loading 500 Ohms)
Outputs: CUT, BLEND, COAG, MICRO
Modes: Monopolar and Bipolar for all outputs
Dimensions: 260x250x75 mm
Switch: Foot controlled pneumatic
www.smt-praha.com
Electrosurgery
www.smt-praha.com
Electrosurgery-Accessories
• 2.4 mm Hand
Controlled/electric:
• 2.4 mm / all branches
• 1.6 mm / dental
• 0.8 mm / cosmetics
Foot Controlled/pneumatic:
ESU Pencils
www.smt-praha.com
• Silicone
• Stainless Steel
• Disposable
Neutral Electrodes
• Blades
• BALLs
• Needles
• LOOPs
• Special Mono Tools
• Bipolar Tools
Operating Electrodes
Electrosurgery-Accessories
Suction Unit SMT CEL-1
Dimensions 510 x 250 x 250 mm
Weight 13 kg
Feeding 230 V; 50 Hz
Rated current 6,55 A
Power 1300 W
Protection IP44
www.smt-praha.com
The controlled destruction of tissue by freezing
Cheap, easy, and safe treatment suitable for both hospital and office based practice
Can remove a lesion with excellent cosmetic results and minimal scarring
Cryosurgery
General information
www.smt-praha.com
warts, moles, skin tags, solar keratoses and small skin cancers
liver cancer, prostate cancer, lung cancer, oral cancers, cervical disorders and, more commonly in the past, hemorrhoids
Cryosurgery works by taking advantage of the destructive force of freezing temperatures on cells
for small lesions, liquid nitrogen can be applied using a Cryospray CS1 / CS1 E/ CS1 SM
because liquid nitrogen is extremely cold (-196 °C), the treated area turns white from frost
Uses
Cryosurgery
www.smt-praha.com
Cryosurgery is a minimally invasive procedure, and is often preferred to more traditional kinds of surgery because of its minimal pain, scarring, and cost.
Many benign skin growths can be safely treated with cryosurgery.
Warts and pre-malignant lesions related to chronic sun exposure (known as actinic keratoses) are some of the most commonly treated lesions in Dermatology.
Results
Cryosurgery
www.smt-praha.com
Patients will notice mild swelling and redness immediately after the procedure.
A small blister may appear a few hours after the treatment.
The lesion should be kept dry for the next 24 hours. Gentle cleaning with water and soap is recommended.
Aftercare
Cryosurgery
www.smt-praha.com
www.smt-praha.com
Extremly high freezing power and rate Large offer of operating instruments and tips Extremely safety automatic operation Automatically controlled operating temperature Dimensions 250x290x75 mm
Cryosurgery
SMT KCH 450 A (M, MD, MDT)
-190°C/-310°F
Liquid Nitrogen
CRYOSURGERY MICROPROCESSOR
SYSTEM
CRYOSPRAY SMT CS 1
www.smt-praha.com
One hand manipulation Precisely localized destruction Enormous safety Large selection of operation spray jets and contact tips Standard tips: J4, J6, J8 For use with liquid nitrogen only Container Capacity: 0,5L
Cryosurgery
-190°C/-310°F
Liquid Nitrogen
CRYOSPRAY SMT CS 1 SM
www.smt-praha.com
One hand manipulation Precisely localized destruction Enormous safety Large selection of operation spray jets and contact tips Standard tip: J6 For use with liquid nitrogen only Container Capacity: 0,2L
Cryosurgery
-190°C/-310°F
Liquid Nitrogen
CRYOSPRAY SMT CS 1 E
www.smt-praha.com
One hand manipulation Precisely localized destruction Enormous safety Large selection of operation spray jets and contact tips Standard tip: J6 For use with liquid nitrogen only Container Capacity: 0,5L
Cryosurgery
-190°C/-310°F
Liquid Nitrogen
CRYO-S
Nitrous oxide N2O – minus 89°C (-128°F)
Carbon dioxide CO2 – minus 79°C (-110°F)
www.smt-praha.com
Cryosurgery
Electric Mini Classic
Fast and effective freezing of tissue Exchangeable contact or spray-type
KL Nitrogen Containers
www.smt-praha.com
Transportation of liquid nitrogen Can be used in cryogenic instalation Container Capacity: 7L/20L/32L
Cryosurgery
PIPE 1
Comfortable withdrawal of liquid nitrogen from KL Dewar dusk Keeps pressure from 20 kPa – 30 kPa
THERMOCAUTER TEK 1
4 operational instruments Operational temp. +700 ÷ 900 °C Recharger unit - Stand Operational tips
www.smt-praha.com
Thermosurgery
THERMOCAUTER TEK 11
www.smt-praha.com
1 operational instrument Operational temp. +700 ÷ 900 °C Independent on the mains Operational tips
Thermosurgery
Certification
www.smt-praha.com
Speciální Medicínská Technologie, s.r.o. Special Medical Technology, Co. Ltd.
Address: Papirenska 114/5, Praha 6, 160 00, Czech Republic
E-mail: [email protected]
Website: www.smt-praha.com
Managing Director: Eng. Lukas Krotil [email protected]
Contact
www.smt-praha.com
Special Medical Technology
www.smt-praha.com
SPECIALISATION
General Surgery
www.smt-praha.com
SMT BM M PF 300W
SMT BM M PF 350W
SMT BM M PF 400W
SMT BM M 300W
SMT BM M 350W
SMT BM M PF 400W
General Surgery
www.smt-praha.com
• Menetriere disease
• Malignant neoplasia
• Gastrointestinal stromal tumors
• Gastric carcinoma
Used for:
Gastrectomy
Preparation of the gastroduodenal artery, dissection of the lymphatic tissue.
Gastrectomy is the surgical removal of all or part of the stomach.
General Surgery
www.smt-praha.com
• Struma
• Thyroid carcinoma
• Autonomous adenom
Used for:
Thyroidectomy with BiClamp
Use of the BiClamp enables a ligature-free ablation of the upper and lower pole vessels. No foreign material remains behind at the operation site.
Thyroidectomy is a surgical procedure in which all or part of the thyroid gland is removed.
General Surgery
www.smt-praha.com
• Diverticulosis (in the case of peritonitis, abscesses or fistulas)
• Ulcerative colitis
• colon carcinoma
• Bowel obstruction
Used for:
Colectomy
Sealing and dissection of the tissue structures.
Colectomy is the excision of the colon or of a portion of it.
General Surgery
www.smt-praha.com
• Recurrent tonsillitis
• Obstructive tonsillar hyperplasia
• Focal infections
• Tonsillar abscess
Used for:
Tonsillectomy by BiClamp
The anterior palatal arch is incised with the bipolar forceps.
Tonsilectomy is the excision of tonsils, treatment of chronic infection of the tonsils .
www.smt-praha.com
SMT BM GYN/SURG 125 W
SMT BM M PF 300W
SMT BM M PF 350W
SMT BM M PF 400W
Gastroenterology
www.smt-praha.com
• Polyps (flat, raised lesions, sessile, waisted or stalked polyps
Used for:
Polypectomy is the removal of a polyp.
Ablation of stalked polyps
Polypectomy with ENDO CUT
Gastroenterology
www.smt-praha.com
• Cholelitiasis with biliary obstruction (gallstones with bile duct blockage)
• Benign papillary stenoses
• Narrowing of the minor duodenal papilla with pancreas divisum
Used for:
Papillotomy is an incision into a papilla; usually in reference to the major duodenal papilla.
Cutting stage during papillotomy procedure.
Papillotomy with ENDO CUT
Gastroenterology
www.smt-praha.com
• Zenker's diverticulum (pouch-like protrusion of the esophageal wall)
Used for:
Argon Plasma Coagulation (APC) treatment is procedure used primarily to control bleeding from certain lesions in the gastrointestinal tract and to debulk tumours.
Zenker´s diverticulum
APC treatment of Zenker´s diverticulum
Gastroenterology
Gynecology
www.smt-praha.com
SMT BM GYN/SURG 125 W
SMT BM M PF 300W
SMT BM M PF 350W
SMT BM M PF 400W
www.smt-praha.com
• Benign, and depending on the indication, malignant changes to the cervix
• Uterus myomatosus (enlarged uterus)
• Adenomyosis uteri (uterine endometriosis)
Used for:
Total Laparoscopic hysterectomy (TLH) is complete removal of the uterus and cervix.
Total Laparoscopic hysterectomy using biclamp.
Gynecology
THL using the biclamp
www.smt-praha.com
• Benign changes to the cervix
• Uterus myomatosus (enlarged uterus)
• Adenomyosis uteri (uterine endometriosis)
• Precancerous conditions
• As part of prolapse surger
Used for:
Vaginal hysterectomy is performed entirely through the vaginal canal.
Amputation of the uterus at the adnexa.
Gynecology
Vaginal Hysterectomy with biclamp
www.smt-praha.com
• Submucous myomas
• Polyps
• Adhesions or septa in the uterine region
• Mucous membrane changes in the uterus (endometrium)
• Metrorrhagia
Used for:
Resection performed through the cervical opening of the uterus.
Transcervical resection
Gynecology
Transcervical resection with bipolar cut
www.smt-praha.com
• Suspicion of lymph node metastasis Used for:
Lymphadenectomy is excision of one or more lymph nodes.
Gynecology
Lymphadenectomy with bipolar LAP scissors
Excision of the lymph node using the bipolar LAP scissors.
www.smt-praha.com
• Benign and malignant changes to the cervix
• Uterus myomatosus (enlarged uterus)
• Adenomyosis uteri (uterine endometriosis)
• Adhesions in the region of the uterus
• Endometriosis
Used for:
Laparoscopic assisted vaginal hysterectomy is the procedure using laparoscopic techniques to remove the uterus and tubes and ovaries through the vagina.
Preparation, coagulation and dissection of the adnexa.
Gynecology
LAVH with LAP Bisect Macro
www.smt-praha.com
• Benign changes to the cervix
• Adenomyosis uteri (uterine endometriosis)
• Uterus myomatosus (enlarged uterus
Used for:
The laparoscopic-assisted supracervical hysterectomy (LASH) is the procedure to remove the uterus without removing the cervix.
Coagulation and dissection of the uterine vessels.
Gynecology
LASH using Bicision
www.smt-praha.com
SMT MB 75W SMT BM DERM 100W
Ophtalmology/Plastic Surgery
www.smt-praha.com
• Chalazion / cyst Used for:
Chalazion removal using needle scalpel.
Chalazion removal
Ophtalmology/Plastic Surgery
www.smt-praha.com
• Entropion / inward-folding eyelid
Used for:
Preparation of the gastroduodenal artery, dissection of the lymphatic tissue.
Eyelid Surgery for Entropium
Ophtalmology/Plastic Surgery
Urology
www.smt-praha.com
SMT BM GYN/SURG 125 W
SMT BM M PF 300W
SMT BM M PF 350W
SMT BM M PF 400W
Urology
www.smt-praha.com
• Muscle-invasive bladder carcinoma Used for:
The laparoscopic cystectomy is the procedure which strips the cyst wall. The portion of the cyst containing the endometrial tissue.
Sealing and dissection of bladder tissue structures.
Laparoscopic Cystectomy
Urology
www.smt-praha.com
• Benign prostatic hypertrophy
• Early bladder cancer, bladder diverticulum
Used for:
Endoscopic removal of the prostate gland or bladder lesions, usually for relief of prostatic obstruction or treatment of bladdermalignancies.
Prostataresection
Transurethral bipolar resection
www.smt-praha.com