COAL HANDLING PLANT
FUNCTION - Automatic feeding of coal to boiler furnace
PROCESS - 1) Coal is unloaded from rail wagons in IV unit of
KSTPS
2) Coal is sent to crusher where coal is reduced to
very small size
Consumption of coal/Unit of electricity - 0.6 Kg
Consumption/day - 20000 tons/day
DEVICES -
1) Wagon Tripler - 5 (32 wagons/hr)
2) Vibration Feeders - Electromagnetic Type
3) Conveyor belts
4) Crushers - 6 (550 tons/hr)
-
8/22/2019 Spec Pics r3
3/19
Raw coal from bharatcoal ltd. Dhanbad &bilaspur(MP)
To KSTPS from gudla via a
single railway track
Wagon
tippler
hoppersCrusher housebunkers
Row coal
feeders
Coal mills
(pulverization)
Boiler furnace ( tangential firing of
pulverized coal)
-
8/22/2019 Spec Pics r3
4/19
WATER CLEANING
CHEMICAL
MIXER
FILTER
BED
CLARIFLOCULATOR
TANK
CLARIFY
WATER
SUMP
FLASH
MIXER
PUMP
PUMP
CLARIFY
WATER
STORAGE
VALVE
RAW
WATER
-
8/22/2019 Spec Pics r3
5/19
CWPH
1-5
CONDENSOR
6-7
COOLING
TOWER 6-7
CWPH
6-7
DM PLANTWTP
CONDENSOR
1-5
CLOSED LOOP
SYSTEM
SOFT
WATERDM
WATERCLARIFIED
WATER
RAW
WATER
FILTER
WATER
OPEN LOOP
SYSTEM
WATERCYCLECHAMBAL
UPSTREA
M
RIVE
R
HOT
WATER
-
8/22/2019 Spec Pics r3
6/19
BOILER
-
8/22/2019 Spec Pics r3
7/19
TURBINE
-
8/22/2019 Spec Pics r3
8/19
AIR PRI-HEATER
Function - To raise the temperature of air
Benefit - Increases the efficiency of plant
Type - plate, tubular, regenerative
KSTPS - uses REGENERATIVE type
-
8/22/2019 Spec Pics r3
9/19
Primaryair
Secondaryair
Fluegas
AIR PRE-HEATER
-
8/22/2019 Spec Pics r3
10/19
GENERATOR
It converts mechanical power into electrical power.
PRINCIPLE- Electromechanical energy
conversion
TECHNICAL SPECIFICATION-
Apparent output137.5 MVA
Active output - 110 MW
Power factor
0.85 lagExcitation voltage - 230 Volt
Rated voltage11 KV
Rated speed3000 rpm
Phase connection star-star
-
8/22/2019 Spec Pics r3
11/19
ECONOMISER
Function-To extract some part of
heat from flue gases & heat the
feedwater
Process- Counter flow of flue
gases & water
Benefits- Increases efficiency
-
8/22/2019 Spec Pics r3
12/19
CONDENSER
To provide lowest economic heat rejection
temperature for the steam. Thus saving on
steam required per unit of electricity.
To convert exhaust steam to water for reuse
thus saving on feed water requirement.
-
8/22/2019 Spec Pics r3
13/19
COLLING TOWER
It converts hot water from into cold water.
Its purpose is to re use of the water.
Its increase the efficiency of plant. It increase the per capital investment of plant.
In K.S.T.P.S. only unit 6th and 7th has cooling
tower.
-
8/22/2019 Spec Pics r3
14/19
-
8/22/2019 Spec Pics r3
15/19
ELECTROSTATIC PRECIPITATOR
15
Used for the removal of suspended particles and fly ash fromindustrial flue gases
PRINCIPLE- Produces an electrostatic field which attracts the
ionized carbon particles and other such particulates which cause
environmental pollution.
-
8/22/2019 Spec Pics r3
16/19
SWITCHYARD
Place where switching operations of power
distribution is perfomed.
Outgoing FeederBeawer feeder -1,2
Heerapura feeder - 1,2
Sakatpura Feeder - 1,2,3
-
8/22/2019 Spec Pics r3
17/19
220KV SWITCHYARD
Main Equipment Of Switchyard
Bus Bar Bus Coupler Isolating switch Earthing Switch Lightning Arrester Current & Potential Transformer (CT&PT) Circuit Breaker Capacitive Voltage Transformer (CVT) Wave Trap Supporting Structures
-
8/22/2019 Spec Pics r3
18/19
TRANSFORMER
GENERATINGTRANSFORMER
UNIT AUXILLARYTRANSFORMER
STATION
TRANSFORMER
EXCITATION
TRANSFORMER
TRANSFORMER
-
8/22/2019 Spec Pics r3
19/19
CONCLUSION