SP2 - VoIP Multicast Paging and Intercom · the simplicity of “press to page, release to party”...
Transcript of SP2 - VoIP Multicast Paging and Intercom · the simplicity of “press to page, release to party”...
Serverless Page/Party®
VoIP Multicast Paging and Intercom
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
is GAI-TRONICS’ most advanced paging and intercom system yet. Combining
the simplicity of “press to page, release to party” operation with cutting-edge multicast Voice
over Internet Protocol (VoIP) technology, SP2 is capable of providing virtually instant communi-
cation in the most demanding of environments.
SP2 is a serverless system. While other systems rely on servers to route calls and administrate
the system, SP2 uses multicast technology, bypassing the need for servers and resulting in a
number of benefits.
•SP2 is fast. Since no server is needed to set up call routing and conference bridges, SP2
can provide immediate one way paging and full-duplex “party line” communication.
•SP2 is simple. There’s no keypad, no extensions to memorize. Simply lift the handset,
select a paging zone, squeeze the handset pressbar, and make an announcement over
the system speakers. Release the pressbar and talk on one of the five available party lines.
•SP2 is reliable. There are no servers to fail or update. SP2 will also notify you of any
problems via e-mail.
• SP2 is flexible. Every SP2 station is capable of being configured with unique characteristics,
including priority, zone destinations, volume levels and so on. Indoor, weatherproof and
hazardous area stations with worldwide approvals are available, ensuring that SP2 can be
used everywhere it’s needed
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
SP2 is simply wired to the nearest network switch using CAT5/CAT5E Ethernet cable, or Fiber
Optic Cable. Local power (AC or DC) is supplied to each station either as a separate power
cable or contained in a hybrid power / network cable. Simple screw terminals within the station
make field wiring possible without the need for any special tools.
Since SP2 is a serverless system, it can easily be integrated into an existing IP network.
This can significantly reduce the installation cost of SP2 and simplify plant data architecture.
All SP2 stations feature a 30W, class D speaker amplifier. This amplifier is capable of producing
paging output of up to 126dB when matched with GAI-TRONICS’ 30W horn / driver combination.
SP2 stations can be supplied with a handset, for paging and intercom, or without a handset for
where only paging coverage is needed.
SP2 Architecture
Series Overview
Network switch
(provided by others)
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
Rugged ConstructionReliable communications in any environment
High visibility orange finish
ReceiverHearing aid compatible
Universal AC or 24VDC Power Worldwide operation
Party Line Selector SwitchSimple conference calls
Paging PressbarOne-handed operation
Optional Page Zone Selector SwitchConfigurable zoning for every SP2 station
Dynamic MicrophoneBuilt-in noise cancellation ensures clear
communication in high noise environments
30 Watt Speaker Amplifier with Ambient Noise Compensation
Clear sound in any environment
SP2 Features and Controls
SP2 was designed with the user in mind. SP2 features simple controls that are easily operable while wearing gloves. A handset with a high-output receiver and noise-cancelling microphone ensures clear communication in high noise areas.
Series Overview
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
SP2 Connections
Each SP2 station can be expanded with several peripheral devices.
A 30W external speakerprovides up to 126dB ofpaging audio
A flashing beacon attracts attention in very high noise areas
A headset enables hands-free operation in any envi-ronment
A two-way 600Ω audioconnection enables simpleinterfacing with other sys-tems
600Ω
Series Overview
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
SP2 Series Variants
SP2 stations are available with many different mounting and environmental options, allowing SP2 to be used in every area of thefacility.
Indoor Wall-mount Stations Indoor Remote-mounted Subset Stations
Weatherproof Wall-mount Stations Explosion-proof Stations
Zone 2 Stations
Series Overview
Series Overview
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
Technical Data - SP2 Series Specifications
Indoor Wall-mount Stations
ElectricalAC Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120/230 V acInput Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50/60 HDC Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V dcNetwork Requirements . . . . . . . . . 100 BaseT network with IGMP
HandsetMicrophone . . . . . . . . . . . . . . . . . . . . . . . Dynamic, noise-cancellingMicrophone Noise Discrimination . . . . . . . . . . . . . . 18dB @ 250HzReceiver . . . . . . . . . . . . . . . . . . . . Dynamic, hearing aid compatibleExternal Control . . . . . . . . . . . . . . Push-to-page handset pressbar
Handset AmplifierOutput Level (compression controlled). . . . . . . . 1.5VRMS nominalFrequency Response . . . . . . . 250-6,500 Hz, +0/-3dB ref. to 1KHzDistortion . . . . . . <1.5% THD @ 1KHz (below compression level)Receiver Level . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mVRMS nominal
Network ConnectionCAT5/5E Stations. . . . . . . . . . . . . . . . . . . . . . . . . . … Screw TerminalsFiber Optic Station . . . . . . . . . . . . . . . . . . . . . . … Standard SFP Port
Speaker AmplifierMax Output . . . . . . . . . . . . 30W into 8Ω load with 1.5VRMS inputFrequency Response:
Distortion . . . . . . . . . . . . . . . . . . . . . . . <1% THD @ 1KHz to 24W<3% THD @ 1KHz to 30W
MechanicalConstruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 gauge cold-rolled steelFinish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety orange powder coatingConnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw-type barrier terminal blocksDimensions (overall). . . . . . . . . . . . . . . . . . 12.5 H x 5.25 W x 7.34 D inches (317.5 x 133.4 x 188.4 mm)Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … -22° F to +140° F (-30° C to +60° C)Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95%, non-condensing
ApprovalsElectical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with IEC 60950 and UL 60950CE Mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with Low Voltage Directive 73/23/EEC,
and the EMS Directive 89/336/EEC amended by the Directive 93/68/EECNRTL Listed . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Hazardous locations, Class I, Div. 2, (USA and Canada)
Groups A, B, C, D
MountingPartyLines
Station Type
Connection/ Control Handset Approval Finish Options Entries
SP2Series
9 1 X X X X X X X 0
AC Handset/Speaker 1AC Handset/Speaker/Aux 2AC Speaker 3DC Handset/Speaker 5DC Handset/Speaker/Aux 6DC Speaker 7
CE BUL CI D2 S
Amp Only 0Multi Party 5
Amp Only 06’ PVC 115’ PVC 225’ PVC 36’ Hytrel® 415’ Hytrel® 525’ Hytrel® 6
No Options 0Trop TR A70/100V R70/100V, TR S
Orange 1Gray 2
—
Indoor Wall-mount SP2 Part Numbers*:
* Items marked as “X” are configurable. Not all option combinations are possible – please contact GAI-TRONICS for assistance.
Technical Data - SP2 Series Specifications
Ethernet with RTU 2Ethernet with ALT Page and RTU 4
Ethernet with AllCall and RTU 6
Fiber with RTU* BFiber with Alt Calland RTU* D
Fiber with All Calland RTU* F
Note: *Fiber optic stations require a suitableSFP module. Contact GAI-TRONICS for more information.
Series Overview
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
Indoor Remote-mounted Subset Stations
MechanicalConstruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 gauge cold-rolled steelFinish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety orange powder coatingConnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw-type barrier terminal blocks
DB25 connection to subsetDimensions (overall). . . . . . . . . . . . . . . . . . 12.5 H x 5.25 W x 4.37 D inches (317.5 x 133.4 x 111.1 mm)Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … -22° F to +140° F (-30° C to +60° C)Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95%, non-condensing
ApprovalsElectical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with IEC 60950 and UL 60950CE Mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with Low Voltage Directive 73/23/EEC,
and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC
* Items marked as “X” are configurable. Not all option combinations are possible – please contact GAI-TRONICS for assistance.
IndoorWall-mount
PartyLines
Station Type
Connection /Control Remote Approval Finish Options Entries
SP2Series
9 3 0 X X 0 X X X 0
UL Safety RCE B
No Options 0Trop TR A70/100V R70/100V, TR S
Orange 1Gray 2
—
Desktop / Wall-mounted Subset SP2 Part Numbers*:
Remote Amplifier SP2 Part Numbers*:
Remote Amplifier
Desktop / Wall-mount Subset
MountingPartyLines
Station Type Operation Handset Approval Finish Options Entries
SP2Series
8 4 5 0 0 8 X 3 X 0
UL Safety RCE B
No Options 0Trop TR A
—
MechanicalConstruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Black ABS housing with aluminum front panelConnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DB25 connection to remote amplifierDimensions (overall). . . . . . . . . . . . . . . . . . . . . 8.94 H x 7.6 W x 4.56 D inches (227.1 x 193 x 115.8 mm)Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … -22° F to +158° F (-30° C to +70° C)Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95%, non-condensing
ApprovalsElectical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with IEC 60950 and UL 60950CE Mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with Low Voltage Directive 73/23/EEC,
and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC
Technical Data - SP2 Series Specifications
Ethernet with RTU 2Fiber with RTU* BNote:
*Fiber optic stations require a suitableSFP module. Contact GAI-TRONICS for more information.
AC Remote Handset/Speaker Station 4DC Remote Handset/Speaker Station 8
Series Overview
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
Indoor Remote-mounted Subset Stations - cont.
MechanicalConstruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 gauge cold-rolled steelFinish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety orange powder coatingConnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DB25 connection to remote amplifierDimensions (overall)
Flush-mount . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 H x 6 W x 5.61 D inches (152.4 x 152.4 x 142.5 mm)Desk-edge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 H x 3.19 W x 7.01 D inches (127 x 81 x 178 mm)
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … -22° F to +140° F (-30° C to +60° C)Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95%, non-condensing
ApprovalsElectical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with IEC 60950 and UL 60950CE Mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with Low Voltage Directive 73/23/EEC,
and the EMS Directive 89/336/EEC amended by the Directive 93/68/EEC
Mounting5-Party
Lines SubsetSubset Handset Approval Finish Options EntriesSP2
Series
8 X 5 0 0 X X X X 0
UL Safety RCE B
Flush-mount 5Desk-edge 6
No Options 0Trop TR A
Orange 1Gray 2
—
Flush-mount and Deskedge Subsets SP2 Part Numbers*:
Flush-mount and Deskedge Subsets
Explosionproof Wall-mount Stations
6’ PVC 115’ PVC 225’ PVC 3
6’ Hytrel® 415’ Hytrel® 525’ Hytrel® 6
PartyLines
Station Type
Connection / Control
OutdoorWall-mount Handset Approval
Gray EpoxyFinish Options Entries
SP2Series
9 2 5
UL CI D1 CATEX Zone 1 EIEC Zone 1 G
Amp Only 0Multi Party 5
UL 12x1.5NPT2x0.75NPT
ATEX/IEC 22xM402xM20
No Options 0Trop TR A
—
Explosion-proof Wall-mount SP2 Part Numbers*:
Ethernet with RTU 2Ethernet with ALT Page and RTU 4
Ethernet with AllCall and RTU 6
Fiber with RTU* BFiber with Alt*Page and RTU D
Fiber with All*Call and RTU F
Amp Only 06’ PVC 115’ PVC 225’ PVC 36’ Hytrel® 415’ Hytrel® 525’ Hytrel® 6
X X X X XX
* Items marked as “X” are configurable. Not all option combinations are possible – please contact GAI-TRONICS for assistance.
Technical Data - SP2 Series Specifications
MechanicalConstruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cast aluminum with gray epoxy coatingConnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw-type barrier terminal blocksDimensions (overall) . . . . . . . . . . . . . . 14.31 H x 13.06 W x 11.68 D inches (363.6 x 331.8 x 296.6 mm)Temperature range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … -4° F to +140° F (-20° C to +60° C)Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95%, non-condensingEnvironmental Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type 4X (IP66)
ApprovalsElectical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with IEC 60950 and UL 60950CE Mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with Low Voltage Directive 73/23/EEC,
and the EMS Directive 89/336/EEC amended by the Directive 93/68/EECNRTL (Listed USA and Canada) . . . . . . . . . . . . . . . . Hazardous locations, Class I, Div. 1, Groups B, C, D
Class II, Div. 1, Groups F, G, Class III, Div. 1, T6ATEX/IECEx Certified . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II 2 G Ex d [ib] IIB + H2 T6
X
Note: *Fiber optic stations require a suitableSFP module. Contact GAI-TRONICS for more information.
AC Handset/Speaker 1AC Speaker 3DC Handset/Speaker 5DC Speaker 7
Note: *Fiber optic stations require a suitableSFP module. Contact GAI-TRONICS for more information.
Series Overview
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
Weatherproof Wall-mount Stations
MechanicalConstruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Engineered glass-reinforced plasticConnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw-type barrier terminal blocksDimensions (overall) . . . . . . . . . . . . . . . . . . . . . . . 14.6 H x 10.9 W x 10.5 D inches (371 x 276 x 267 mm)Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … -22° F to +140° F (-30° C to +60° C)Relative Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95%, non-condensingEnvironmental Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type 4X (IP66)
ApprovalsElectical Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with IEC 60950 and UL 60950CE Mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Complies with Low Voltage Directive 73/23/EEC,
and the EMS Directive 89/336/EEC amended by the Directive 93/68/EECNRTL Listed . . . . . . . . . . . . . . . . . . . . . . . . . . . . … Hazardous locations, Class I, Div. 2, (USA and Canada)
Groups A, B, C, D
OutdoorWall-mount
PartyLines
Station Type
Connection / Control Handset Approval Finish Options Entries
SP2Series
9 2 X X X X X X X 0
AC Handset/Speaker 1AC Handset/Speaker/Aux 2AC Speaker 3DC Handset/Speaker 5DC Handset/Speaker/Aux 6DC Speaker 7
CE BUL CI D2 S
Amp Only 0Multi Party 5
Amp Only 06’ PVC 115’ PVC 225’ PVC 36’ Hytrel® 415’ Hytrel® 525’ Hytrel® 6
Orange 1Gray 2
—
Ethernet with RTU 2Ethernet with ALT Page and RTU 4
Ethernet with All Call and RTU 6
Fiber with RTU* BFiber with Alt Page and RTU* D
Fiber with All Calland RTU* F
Weatherproof Wall-mount Station SP2 Part Numbers*:
* Items marked as “X” are configurable. Not all option combinations are possible – please contact GAI-TRONICS for assistance.
No Options 0Trop TR ASpring Kit SK BVee Notch VN CLock Door LD DLD, SK ELD, VN FLD, TR GSK, VN HSK, TR JVN, TR KLD, SK, VN LLD, SK, TR MLD, VN, TR NLD, SK, VN, TR P
Technical Data - SP2 Series Specifications
Series Overview
GAI-TRONICS® A Hubbell Company www.gai-tronics.com
Accessories
Acoustic Hood - 9/14dB
• 6866-001 – Yellow hood 9dB• 6866-002 – Gray hood 9dB• 6866-003 – Yellow hood 14dB• 6866-004 – Gray hood 14dB
Acoustic Hood - 23dB
• 988-60-0002-701 – Yellow hood• 988-60-0002-702 – Red hood• 988-60-0002-703 – Orange hood• 988-60-0002-704 – Blue hood
Headset / Extension Cable
• 10401-201 – Headset/Microphone• 10416-103 – 30’ Extension cable with push-to-page switch• 10416-104 – 50’ Extension cable with push-to-page switch• 10416-105 – 8’ Extension cable with push-to-page switch
Subset Extension Cable
• 12587-101 – 25’ Subset extension cable with fitted connectors.• 12587-102 – 25’ Subset extension cable with fitted connectors and wall plate.• 12587-104 – 15’ Subset extension cable with one fitted and one loose connector.
Technical Data - SP2 Series Specifications
Contact your sales representative or call our toll-freesales hotline for further information at 1-800-492-1212.
Look to GAI-TRONICS, a leader in the emergency notification industry through its innovative products, uncompromising quality and advanced technology.
Visit us @ www.gai-tronics.com
Pub. 160303 Rev 9/2018
Quality Management System Certified by DNV-GL - ISO 9001:2015. The policy of GAI-TRONICS is one of continuous improvement; therefore the company reserves the right to change specifications without notice.