Southwest Research Institute NSF Conference on Small Satellites Plasma Instrument Miniaturization...
Transcript of Southwest Research Institute NSF Conference on Small Satellites Plasma Instrument Miniaturization...
Southwest Research InstituteSouthwest Research Institute
Plasma InstrumentMiniaturization and Integration:
Approaches and Limitations
C.J. Pollock, R. Torbert, and D.T. Young
Southwest Research InstituteSouthwest Research Institute
Plasma Instrument Miniaturization and Integration: Approaches and Limitations
- Functional Guidelines- Measurement Focus- Sensor vs Electronics- System Integration
-Examples of Low Resource Flight or Prototype Instruments- PEPE
- IES- TECHS- MOSS
-Limitations and Pitfalls:- It takes an aperture- It often takes high voltage
Southwest Research InstituteSouthwest Research Institute
Functional Guidelines
Measurement Focus• Disciplined approach that focuses narrowly on priority science• Sensor technologies for disparate plasma regimes:
• Langmuir Probe – Temperature and density of thermal plasma• Segmented Faraday Cup/RPA: High Mach # flowing plasma• Curved Plate ESA: Low mach number, structured plasma distributions
Sensor vs Electronics• In some cases there are limitations to sensor size reduction (aperture size dictates signal)
( X ~ A1A2/L2)
• Other times, the electronics may be irreducible (high voltage circuits)
System Integration vs Modularity(?)• A high degree of functional integration is helpful to minimize resource consumption and unintended functional redundancy;• Still, developmental modularity allows parallel development, often critical for small budget/short time scale flight development
Southwest Research InstituteSouthwest Research Institute
Particle Experiment for Planetary Exploration (PEPE) on Deep Space-I
• Developed as outgrowth of Dave Young’s Internal Research project at SwRI, entitled: Miniaturized, Optimized Smart Spectrometer (MOSS)
• Designed as a low resource, high performance electron and ion composition spectrometer
• Design principals include:• Innovative use of materials to reduce mass (ESAs are plated plastic)• Tight integration of electronics and sensor• Ions and electrons share entrance aperture
• ~5 kg, 5W dual spectrometer with LEF TOF measurement included
Southwest Research InstituteSouthwest Research Institute
Miniature -15kV Power Supply
Southwest Research InstituteSouthwest Research Institute
Flight Model – Ready for Cal
Southwest Research InstituteSouthwest Research Institute
Thermal Electron Capped Hemisphere Spectrometer(TECHS)
• Developed to target thermal electron fluxes in Earth’s ionosphere;
• Extreme miniaturization of tophat ESA necessary to measure low energy electrons in Earth’s ~0.4G field;
• Prime target electron energy from 0.1 to 100 eV
• Radius of curvature of ESA plates ~5mm.
• ESA Analyzer gap < 1 mm
• With analyzer ratio of ~7, application of 1kV ESA voltage would allow viewing of 7 keV electrons;
• Sensor the size of 35 mm film can;
• pre-amp boom and electronics box presently occupies more macroscopic scale.
Southwest Research InstituteSouthwest Research Institute
Southwest Research InstituteSouthwest Research Institute
A Very Small & Very Black Inner Tophat Electrode
Southwest Research InstituteSouthwest Research Institute
TECHS Sensor Elements
Southwest Research InstituteSouthwest Research Institute
E-box and Boom Not So Small (room for improvement)
Southwest Research InstituteSouthwest Research Institute
Southwest Research InstituteSouthwest Research Institute
Ion an Electron Sensor (IES) on Rosetta
• This was an exercise in extreme resourse conservation, patterned on the PEPE development.
• Dual, shared aperture ion and electron tophats with FOV deflection
• No time of flight (read: no ion composition)
• Tightly integrated but no modularity (difficult to troubleshoot and repair)
• Good performance obtained;
• Flight resource requirements: 1.25 kg; 1.8 Watts
• Severe compromises sometimes required. In IES, for example, to save power, the 1st HV step on the z-style MCP stack is 2.5 kV (for both electron and ion stacks), and the stacks are enabled and commanded in common;
• This is scary (perhaps less so for those with rocket background); It has worked well on orbit.
Southwest Research InstituteSouthwest Research Institute
IES Sensor Design
Southwest Research InstituteSouthwest Research Institute
Rosetta Ion and Electron Sensor Parameters.Parameter ValueEnergy
Range 1 eV/e to 30 keV/eResolution (DE/E) 0.04Scan Mode-dependent
AngleRange (FOV) 90 x 360º (2.8p sr)Resolution (e-) 5 x 22.5º (16 azimuthal x 16 polar)Resolution (ions) 5 x 45º (16 azimuthal x 7 polar)
Temporal resolution 3D distribution 3 sGeometric factor
Total (ions) 5 x 10-4 cm2-sr-eV/eV count/ionPer 45º sector (ions) 6 x 10-5 cm2 sr eV/eV count/ion
Total (e-) 5 x 10-4 cm2 sr eV/eV count/electronPer 22.5º sector (e-) 3 x 10-5 cm2 sr eV/eV count/electron
Mass 1040 gVolume 1297 cm3
DimensionsSensor: 73 mm dia x 101 mmElectronics box: 139 x 121 x 64 mm
Power 1850 mWDownlink data rate 5 - 250 bit s-1
Southwest Research InstituteSouthwest Research Institute
Southwest Research InstituteSouthwest Research Institute
A MagCon System Concept
• Magnetometer, e and i+ plasma spectrometer, energetic particles
• A 3-instrument suite, integrated with a single central c&dh
• Instruments are sensors with bare bones co-located support circuitry;
• C&DH system that holds all possible command functions;
• C&DH system holds all possible signal processing functions;
Southwest Research InstituteSouthwest Research Institute
Micro-Satellite Architectural Diagram
Southwest Research InstituteSouthwest Research Institute
Final Draco Bench-Top Configuration
CDPU
Mag Sensor
Mag Electronics
IES Elec.
EPSElectronics
Southwest Research InstituteSouthwest Research Institute
Conclusions
• Significant miniaturization in capable plasma instrumentation is possible;
• Limitations exist, however:
• Aperture size sets limits on sensor miniaturization
• HV requirements set limits on certain electronics miniaturization
• Minimum resource plasma instruments and instrument suites can be focused on limited science goals
• Minimum resource/limited capability instrument suites can also be fielded for constellation-class payloads
• Continual investment in instrument & advanced technology development is a must!